Loading...
HomeMy WebLinkAbout428 Squires Ln - 210935101001Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970) 328-8730 Fax: (970) 328-7185 Permit Permit No. OWTS-024691-2022 Permit Type: OWTS Permit Work Classification: New Permit Status: Active Issue Date: 7/15/2022 Expires: 11/14/2022 On-Site Wastewater Treatement System Project Address Parcel Number 428 SQUIRES LN, EAGLE AREA,210935101001 Owner Information Address Greg & Kelly Berger Phone: Cell: (303) 905-2617 Email: Kellybergerart@gmail.com Inspections: For Inspections Call: (970) 328-8755 Engineer Phone Email JVA Inc, Simon Farrell (303) 444-1951 sfarrell@jvajva.com Contractor License Number Phone Email 2020 Excavating LLC cam.gonzales2020@gmail .com (970) 376-0511OWTSPL-000186-20 22 Permitted Construction / Details: Install the new system exactly as depicted in the JVA Inc design dated, stamped and signed on May 24th, 2022 by Simon A. Farrell, PE. This system is designed to accommodate the maximum daily flows for a 4 bedroom residence. This OWTS consists of one sewer line from the residence. The system consists of a Valley Precast 1,250 gallon, single compartment tank with effluent screen and alarm placed on the outlet, followed by a 2,000 gallon Valley Precast 3-compartment recirculating/dose tank which will send wastewater to two, Advantex AX-20 pods for nitrification using an Orenco PF500512 pump. Nitrified effluent flows to the splitter valve (mode 3B) for recirculation to the 1,250 gallon first tank for denitrification then is dosed using an Orenco PF501012 pump to an automatic distribution valve (ADV), set level at the high point of the system and made accessible at grade. The ADV will alternate dosed effluent to 1,872 square feet of soil treatment area (STA). The STA consists of three beds, each arranged with of four rows of 13 Infiltrator Quick 4 Plus Standard chambers for a total of 156 chambers. Maintain all elevations and setbacks. Distribution lateral details, along with orifice size, spacing and orientation are on the design drawing. The contractor must verify that all electrical components and inspections are covered under the electrical permit associated with the Orenco Vericom control panel (Model VCOM-AX20B2) and pump connections. The alarm must be connected to a separate circuit. Additional pump details are on the design drawing. Advantex systems must conform to the CDPHE technology approval letter dated May 1, 2018. Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections necessary to certify the installation and assure functionality of the system. System certification, along with photos and a record drawing is required to be submitted to, and approved by, Eagle County Environmental Health prior to the use of the system or occupancy of the dwelling. Friday, July 15, 2022 1 THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT Issued by: Environmental Health Department, Eagle County, CO Danielle Salinsky Date July 15, 2022 CONDITIONS 1. 2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED 3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED Friday, July 15, 2022 2 *************************************************************************** APPLICATION FOR ON-SITE WASTEWATER TREATMENT SYSTEM (OWTS) PERMIT INCOMPLETE APPLICATIONS MAY NOT BE ACCEPTED (SITE PLAN MUST BE INCLUDED) FEE SCHEDULE APPLICATION FEE FOR NEW OWTS OR MAJOR REPAIRS $800.00 MINOR REPAIR FEE $400.00 Fee includes the design review, permitting and maintenance of OWTS records Make all checks payable to: Eagle County Treasurer Property Owner: _______________________________________Phone: ________________________ Owner Mailing Address: ________________________________ email: _________________________ Professional Engineer: __________________________________ Phone: ________________________ Applicant / Contact Person: ______________________________Phone: ________________________ Licensed Systems Contractor Name / Company: ___________________________________________ Contractor Mailing Address: _________________________________ Contractor License #:_______ Contractor Phone Number: ________________________ email: ______________________________ OWTS Permit Application is for: ____ New Installation ____ Alteration ____ Repair Tax Parcel Number: _________________________________ Lot Size: ________________________ Assessor’s Link: www.eaglecounty.us/patie/ Physical Address: _____________________________________________________________________ Legal Description: ____________________________________________________________________ Building Type: _____ Residential / Single Family _____ Residential / Multi Family _____ Commercial / Industrial Number of Bedrooms: ______ Number of Bedrooms: ______ Type of Use: _______________ *As of 06/27/2014, all systems require design by a Registered Professional Engineer. Type of Water Supply: ____ Private Well ____ Spring ____ Surface ____ Public If Public, Name of Supplier: ____________________________________________________________ Applicant Signature: ______________________________________Date:_______________________ **************************************************************************** Office Use Only: OWTS PERMIT # __________________ BUILDING PERMIT # ____________________ Amount Paid: ___________ Receipt #: ___________ Check #: ___________ Date: ______________ DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX: (970) 328-8788 TOLL FREE: 800-225-6136 www.eaglecounty.us P.O. Box 179 500 Broadway Eagle, CO 81631 environment@eaglecounty.us GREG & KELLY BERGER 303-905-2617 668 N HUMBOLDT ST DENVER, CO 80218-3606Kellybergerart@gmail.com Simon Farrell, P.E.303-444-1951 Yves Matiethoz, A.I.A.970-453-7002 ext. 5 2020 Excavating LLC 170 Autumn Glen, Gypsum CO 81637 OWTSPL-000137-2021 cam.gonzales2020@gmail.com ✔ 2109-351-01-001 5.131 acres 428 SQUIRES LN FROST CREEK FILING 1 Lot: 2 ✔4 ✔ TOWN OF EAGLE 05/23/2022 OWTSPL-000137-2021 INSPECTION WORKSHEET (INSP-533951-2024) FOR EAGLE COUNTY GOVERNMENT OWTS-024691-2022Case Number:Case Module:Permit Management 08/29/2024 RequestedInspection Status:Inspection Date: OWTS Final InspectionInspection Type:Inspector:Kirk Weems Job Address:Parcel Number:428 Squires Ln Eagle Area, CO 210935101001 Company Name NameContact Type Applicant A.I.A.Yves Matiethoz Contractor 2020 Excavating LLC Camerino Gonzales Engineer JVA Inc Simon Farrell Owner Greg & Kelly Berger CommentsPassedChecklist Item True 08/29/2024 - Confirm tank sizes and installation per JVA Final Documents Septic Tank - Septic Tank True 08/29/2024 - Received from JVARecord Drawing - Record Drawing True 08/29/2024 - Received from JVARecord Photos - Record Photos True 08/29/2024 - Site and soil included in original design packSite and Soil - Site & Soil True 08/29/2024 - Final cert and R&M contract received from JVA.Final Certification Letter - Final Certification Letter True Updated design submitted and approved on 11/28/2022General Plan - General Plan True 08/29/2024 - waiting for gradation analysis for sand filter media 09/04/24 - confirm secondary sand media, gradation in permit file Soil Treatment Area (STA) - Soil Treatment Area (STA) True 2020 Excavating - OWTSPL-000318-2024Identification of Systems Contractor - Identification of Systems Contractor September 04, 2024 Page 1 of 1P.O. Box 179, 500 Broadway, Eagle, CO 81631-0179 August 28, 2024 Claire Lewandowski, Environmental Health Specialist III Eagle County Environmental Health 500 Broadway Street Eagle, CO 81631 RE: Onsite Wastewater Treatment System Final Certification – 428 Squires Lane, Lot 2 Dear Claire: The Onsite Wastewater Treatment System (OWTS) covered under Eagle County Permit No. OWTS-024691-2022 was installed by 2020 Excavating LLC for 428 Squires Lane and is ready for final certification from Eagle County Environmental Health. This letter certifies that the construction of the OWTS was completed as per the approved design plan. The final record drawings from JVA, Maintenance Contract, and construction photographs are provided as attachments. As part of the final approval process JVA observed that start-up was completed by the manufacturer’s representative and completed a site visit to check all system components. The system is connected and can be monitored remotely as required in the PUD. Sincerely, JVA, INCORPORATED By: ________________________ Simon Farrell, P.E. Project Manager, Associate Enclosure: Attachment A – Record Drawings Attachment B – Maintenance Contract Attachment C – Construction Photographs CC: Chelsea Fagan, JVA ATTACHMENT A – RECORD DRAWINGS FROST CREEK LOT 2 ONSITE WASTEWATER TREATMENT SYSTEM EAGLE COUNTY, COLORADO RECORD DRAWINGS AUGUST 2024 Set No._______ JVA, Inc.1319 Spruce Street www.jvajva.com Boulder, CO 80302 303.444.1951 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver DESIGN CRITERIA AND NOTESG0.1 REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY: DRAWN BY: CHECKED BY: JOB #: DATE: © JVA, INC.FROST CREEKLOT 2 OWTSEAGLE, COLORADOSHEET NO. 1037.33 MAY 2022 SAF PMH PMH JVA, Inc.1319 Spruce Street www.jvajva.com Boulder, CO 80302 303.444.1951 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver SWITCHED DISCHARGE PUMP FROM MODEL PF 501012 TO MODEL PF 500712PMHPMHNOV 221AUG 24RGHRGHRECORD DRAWINGS2CONFORMED TO CONSTRUCTION RECORD 7519.99 7520.55 7520.76 7520.93 7520.46 REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY: DRAWN BY: CHECKED BY: JOB #: DATE: © JVA, INC.FROST CREEKLOT 2 OWTSEAGLE, COLORADOSHEET NO. 1037.33 MAY 2022 SAF PMH PMH JVA, Inc.1319 Spruce Street www.jvajva.com Boulder, CO 80302 303.444.1951 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver SWITCHED DISCHARGE PUMP FROM MODEL PF 501012 TO MODEL PF 500712PMHPMHNOV 221AUG 24RGHRGHRECORD DRAWINGS2CIVIL SITE PLANC1.0CONFORMED TO CONSTRUCTION RECOR TREATMENT SYSTEM AND SITE DETAILSCD1.0 REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY: DRAWN BY: CHECKED BY: JOB #: DATE: © JVA, INC.FROST CREEKLOT 2 OWTSEAGLE, COLORADOSHEET NO. 1037.33 MAY 2022 SAF PMH PMH JVA, Inc.1319 Spruce Street www.jvajva.com Boulder, CO 80302 303.444.1951 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver SWITCHED DISCHARGE PUMP FROM MODEL PF 501012 TO MODEL PF 500712PMHPMHNOV 221AUG 24RGHRGHRECORD DRAWINGS2CONFORMED TO CONSTRUCTION RECORD SOIL TREATMENT AREA DETAILSCD1.1 REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY: DRAWN BY: CHECKED BY: JOB #: DATE: © JVA, INC.FROST CREEKLOT 2 OWTSEAGLE, COLORADOSHEET NO. 1037.33 MAY 2022 SAF PMH PMH JVA, Inc.1319 Spruce Street www.jvajva.com Boulder, CO 80302 303.444.1951 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver SWITCHED DISCHARGE PUMP FROM MODEL PF 501012 TO MODEL PF 500712PMHPMHNOV 221AUG 24RGHRGHRECORD DRAWINGS2CONFORMED TO CONSTRUCTION RECORD ATTACHMENT B – MAINTENANCE CONTRACT ATTACHMENT C – CONSTRUCTION PHOTOGRAPHS