HomeMy WebLinkAbout2245 Upper Cattle Creek Rd - 239127402004INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
Telephone:(970)328-8755
P.O.Box 179 -500 Broadway,Eagle,CO 81631
COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE.ISDS PERMIT#IS-2346-04 BUILDING PERMIT #15945
OWNER:PHILIP G.POPKIN PHONE:970-963-8266
MAILING ADDRESS:P.O.BOX 7956,ASPEN,CO 81612
APPLICANT:STEVEN WALDECK PHONE:970-920-4079
SYSTEM LOCATION:2245 EL JEBEL RD.,EL JEBEL,CO TAX PARCEL NO.2391-274-02-004
LICENSED INSTALLER:INDEPENDENT TRUCKING AND EXCAVATION LICENSE NO.63-04 PHONE:970-963-1548
DESIGN ENGINEER:TIMBERLINE ENGINEERING,DAVID POWELL PHONE:970-963-9869
INSTALLATION GRANTED FOR THE FOLLOWING:MINIMUM REQUIREMENTS FOR A 5 BEDROOM RESIDENCE:
1500 GALLON SEPTIC TANK,1883 SQUARE FEET OF ABSORPTION AREA CREDIT VIA 59 EQ36 INFILTRATOR UNITS,AS
PER ENGINEER’S DESIGN REVISIONS DATED 7/01/04.
SPECIAL INSTRUCTIONS:INSTALL IN SHALLOW TRENCHES,AS PER ENGINEER’S DESIGN REVISIONS WITH A
CLEANOUT BETWEEN THE TANK AND THE HOUSE AND INSPECTION PORTALS IN EACH TRENCH.RAKE ALL TRENCH
SURFACES TO PREVENT THE SMEARING OF SOILS AND DO NOT INSTALL IN WET WEATHER.PLACE A MINIMUM OF
SIX (6)INCHES OF SAND MATCHING AS CLOSE AS POSSIBLE THE ISDS SAND IN THE BOTTOM OF THE TRENCHES.
GRADATION ANALYSIS MUST BE PROVIDED TO ENGINEER FOR APPROVAL PRIOR TO PLACEMENT OF SAND.BACK
FILL WITH LOCAL SOILS WHICH ARE STONE OR ROCK FREE AND SCREENED IF NECESSARY.BE SURE TO MAINTAIN
ALL SET BACK REQUIREMENTS:110 FEET FROM THE WELL TO THE LEACH FIELD,60 FEET FROM THE LEACH FIELD
TO ANY WATER COURSES,35 FEET FROM THE LEACH FIELD TO DRY GULCHES,50 FEET FROM THE TANK TO THE
WELL,25 FEET FROM THE WATER LINE TO THE LEACH FIELD,AND 10 FEET FROM WATERLINE TO THE TANK.
CALL EAGLE COUNTY ENVIRONMENTAL HEALTH AND THE DESIGN ENGINEER FOR THE FINAL INSPECTION
PRIOR TO BACK FILLING ANY PART OF THE INSTALLATION,OR IF YOU HAVE ANY QUESTIONS REGARDING
THE INSTALLATION.THE BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC
SYSTEM HAS BEEN INSPECTED AND APPROVED.
ENVIRONMENTAL HEALTH APPROVAL:LAURA FAWCETT DATE:AUGUST 18,2004
CONDITIONS:
1.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS ADOPTED
PURSUANT TO AUTHORITY GRANTED IN 25-10-104,1973,AS AMENDED.
2.THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS.
ONNECTION TO,OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A
VIOLATION OF A REQUIREMENT OF THE PERMIT,AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3.CHAPTER IV,SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS,ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED.
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL
THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA:1829 SQUARE FEET ABSORPTION AREA CREDIT VIA 59
STANDARD INFILTRATOR CHAMBERS.
INSTALLED:1500 GALLON,TWO-COMPARTMENT,CONCRETE SEPTIC TANK.SEE AS-BUILT SITE PLAN PROVIDED BY
THE DESIGN ENGINEER,STAMPED,SIGNED AND DATED OCTOBER 21,2005.
COMMENTS:SEE ENGINEER’S CERTIFICATION STAMPED,SIGNED AND DATED OCTOBER 21,2005 ACCOMPANYING
THIS PERMIT.
ENVIRONMENTAL HEALTH APPROVAL DATE:
DATE:August 18,2004
TO:Independent Trucking &Excavation
FROM:Eagle County Department of Environmental Health
RE:Individual Sewage Disposal System Permit #2346-04,Tax Parcel
#2391-274-02-004.Property Location:2245 El Jebel Rd.,El Jebel,CO.,Popkin
residence.
Enclosed is your ISDS Permit #2346-04 and a copy of the engineer’s design for this system.The
permit is valid for 120 days or for the duration of your current building permit for this property.
The enclosed copy of the permit must be posted at the installation site.Any changes in plans or
specifications invalidate the permit unless otherwise approved.Please note any special
requirements that may have been added to the design by this Department.
Systems that are designed by a Registered Professional Engineer must be certified by the
engineer indicating that the system was installed as specified.Eagle County Environmental
Health must also view the installation prior to back filling.Please call well in advance for
your final inspection.Your TCO will not be issued until our office receives this certification
from the engineer and views the installation.
Please note that our ISDS Permit specifications are typically minimum requirements only and
should be brought to the property owner's attention in case they may wish to install a system
capable of handling larger wastewater flows.
This permit does not indicate conformance with any other Eagle County requirements.Please
notify this office if you have not been contracted to perform this installation.
If you have any questions,please feel free to contact us at (970)328-8755.
cc:ISDS file #2346-04
Timberline Engineering,David Powell
August 2004 Chrono file
Encl:ISDS Permit #2346-04
INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
Telephone:(970)328-8755
P.O.Box 179 -500 Broadway,Eagle,CO 81631
COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE.PERMIT#2346-04 BP#
OWNER:PHILIP G.POPKIN PHONE:970-963-8266
MAILING ADDRESS:P.O.BOX 7956,ASPEN,CO 81612
APPLICANT:STEVEN WALDECK PHONE:970-920-4079
SYSTEM LOCATION:2245 EL JEBEL RD.,EL JEBEL,CO TAX PARCEL NO.2391-274-02-004
LICENSED INSTALLER:INDEPENDENT TRUCKING AND EXCAVATION LICENSE NO.63-04 PHONE:970-963-1548
DESIGN ENGINEER:TIMBERLINE ENGINEERING,DAVID POWELL PHONE:970-963-9869
INSTALLATION GRANTED FOR THE FOLLOWING:MINIMUM REQUIREMENTS FOR A 5 BEDROOM RESIDENCE
1500 GALLON SEPTIC TANK,1883 SQUARE FEET OF ABSORPTION AREA CREDIT VIA 59 EQ36 INFILTRATOR UNITS,AS
PER ENGINEER’S DESIGN REVISIONS DATED 7/01/04.
SPECIAL INSTRUCTIONS:INSTALL IN SHALLOW TRENCHES,AS PER ENGINEER’S DESIGN REVISIONS WITH A
CLEANOUT BETWEEN THE TANK AND THE HOUSE AND INSPECTION PORTALS IN EACH TRENCH.RAKE ALL TRENCH
SURFACES TO PREVENT THE SMEARING OF SOILS AND DO NOT INSTALL IN WET WEATHER.IF ROCKY CONDITIONS
ARE ENCOUNTERED DURING TRENCH EXCAVATION CALL DESIGN ENGINEER AND EAGLE COUNTY
ENVIRONMENTAL HEALTH FOR INSTRUCTIONS ON HOW TO PROCEED.BE SURE TO MAINTAIN ALL SET BACK
REQUIREMENTS:110 FEET FROM THE WELL TO THE LEACH FIELD,60 FEET FROM THE LEACH FIELD TO ANY WATER
COURSES,35 FEET FROM THE LEACH FIELD TO DRY GULCHES,50 FEET FORM THE TANK TO THE WELL,25 FEET
FROM THE WATER LINE TO THE LEACH FIELD,AND 10 FEET FROM WATERLINE TO THE TANK.CALL EAGLE
COUNTY ENVIRONMENTAL HEALTH AND THE DESIGN ENGINEER FOR THE FINAL INSPECTION PRIOR TO BACK
FILLING ANY PART OF THE INSTALLATION,OR IF YOU HAVE ANY QUESTIONS REGARDING THE INSTALLATION.
THE BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS BEEN
INSPECTED AND APPROVED.
ENVIRONMENTAL HEALTH APPROVAL:DATE:JULY 7,2004
CONDITIONS:
1.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104,1973,AS AMENDED.
2.THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING
REQUIREMENTS.CONNECTION TO,OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING
DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT,AND WILL RESULT IN BOTH LEGAL ACTION AND
REVOCATION OF THE PERMIT.
3.CHAPTER IV,SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS,ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO
BE LICENSED.
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE
DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF
THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA:SQUARE FEET (VIA )
INSTALLED TANK:GALLONS IS LOCATED DEGREES AND FEET INCHES
FROM
COMMENTS:
ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE.ARRANGE A
RE-INSPECTION WHEN WORK IS COMPLETED.
ENVIRONMENTAL HEALTH APPROVAL DATE:
DATE:July 7,2004
TO:Independent Trucking &Excavation
FROM:Eagle County Department of Environmental Health
RE:Individual Sewage Disposal System Permit #2346-04,Tax Parcel
#2391-274-02-004.Property Location:2245 El Jebel Rd.,El Jebel,CO.,Popkin
residence.
Enclosed is your ISDS Permit #2346-04 and a copy of the engineer’s design for this system.The
permit is valid for 120 days or for the duration of your current building permit for this property.
The enclosed copy of the permit must be posted at the installation site.Any changes in plans or
specifications invalidate the permit unless otherwise approved.Please note any special
requirements that may have been added to the design by this Department.
Systems that are designed by a Registered Professional Engineer must be certified by the
engineer indicating that the system was installed as specified.Eagle County Environmental
Health must also view the installation prior to back filling.Please call well in advance for
your final inspection.Your TCO will not be issued until our office receives this certification
from the engineer and views the installation.
Please note that our ISDS Permit specifications are typically minimum requirements only and
should be brought to the property owner's attention in case they may wish to install a system
capable of handling larger wastewater flows.
This permit does not indicate conformance with any other Eagle County requirements.Please
notify this office if you have not been contracted to perform this installation.
If you have any questions,please feel free to contact us at (970)328-8755.
cc:ISDS file #2346-04
Timberline Engineering,David Powell
July 2004 Chrono file
Encl:ISDS Permit #2346-04
October 25,2005
Mr.Philip G.Popkin
P.O.Box 7956
Aspen,Colorado 81612-7956
RE:Final approval of Individual Sewage Disposal System ISDS Permit #:IS-2346-04;
Tax parcel #:2391-274-020-04;Property location:2245 El Jebel Rd.,El Jebel
Dear Mr.Popkin:
This letter is to inform you that the above-referenced ISDS Permit has been inspected and
finalized.Your septic system has been sized to accommodate five (5)bedrooms.Enclosed is a
copy to retain for your records along with a brochure regarding the care of your septic system.
Additional information about the maintenance of your septic system as well as information about
private wells can be accessed through web site links provided on the Environmental Health
Department’s home page at http://www.eaglecounty.us/envHealth/
Be aware that changes in the use of your property or alterations of your building may require
commensurate changes to,or relocation of,your septic system.Landscape features,trees with
tap roots,irrigation systems and parking areas above the drain field can cause premature system
failure.It is equally important that you notice and immediately repair dripping faucets and
hissing toilets as this will certainly cause the system to fail.By following a few simple
guidelines,like avoiding grease or other additives down the drain and making sure your septic
tank is on a pumping schedule,your system has been designed to last for many years.
If you have any questions regarding this information,please contact us at (970)328-8755.
Sincerely,
Lori Siefers,Administrative Technician IV
cc:ISDS permit folders
Chronological folder
Timberline Engineering
Eagle County Building Department
Encl:Final ISDS Permit
Informative materials
Copies of pertinent photos from the final inspection
Copy of the engineer ’s certification and as-built drawings