Loading...
HomeMy WebLinkAbout615 Mountain View Rd - 239122202002INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 2211-02 BP NO. 14356 OWNER: DAN AND CYNTHIA ERICKSON PHONE: 970-927-1832 MAILING ADDRESS: 0373 SOPRIS CREEK RD #2.. BASALT. CO 81621 APPLICANT: SAME PHONE: SYSTEM LOCATION: 0615 MOUNTAIN VIEW RD., CARBONDALE, CO TAX PARCEL NO. 2391-222-02-002 LICENSED INSTALLER: ELKHORN EXCAVATING, DALE ALCORN LICENSE NO. 72-02 PHONE: 970-625-4808 DESIGN ENGINEER: HIGH COUNTRY ENGINEERING, ROGER NEAL PHONE NO. 970-945-8676 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 5 BEDROOM RESIDENCE 2000 GALLON SEPTIC TANK, 2170 SQUARE FEET OF ABSORPTION AREA CREDIT, VIA 70 INFILTRATOR UNITS. AS PER ENGINEER'S DESIGN SPECIAL INSTRUCTIONS: INSTALL AS PER ENGINEER'S DESIGN DATED 7/31/02 WITH A CLEAN -OUT BETWEEN THE TANK AND THE HOUSE AND INSPECTION PORTALS IN EACH TRENCH. BE SURE TO MAINTAIN ALL APPLICABLE SET BACK REQUIREMENTS ESPECIALLY FROM THE LEACH FIELD TO THE IRRIGATION DITCH WHICH IS MORE THAN 60 FEET AND THE LEACH FIELD TO THE POTABLE WATER LINE WHICH IS 25 FEET. RAKE ALL TRENCH SURFACES TO PREVENT THE SMEARING OF SOILS AND DO NOT INSTALL IN WET WEATHER. ENCASE THE EFFLUENT LINE CROSSING THE IRRIGATION DITCH ACCORDING TO THE ENGINEER'S SPECIFICATIONS. CALL EAGLE COUNTY ENVIRONMENTAL HEALTH AND THE DE- SIGN ENGINEER FOR THE FINAL INSPECTION PRIOR TO BACK FILLING ANY PART OF THE INSTALLATION OR WITH ANY QUESTIONS RE- GARDING THE INSTALLATION. THE BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS BEEN INSPECTED AND APPROVED. ENVIRONMENTAL HEALTH APPROVAL: LAURA FAWCETT DATE: AUGUST 1, 2002 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 2170 SQUARE FEET (VIA 70 STANDARD INFILTRATOR UNITS AS PER DESIGN ) INSTALLED CONCRETE SEPTIC TANK: 2000 GALLONS IS LOCATED 78 FEET FROM THE CLEANOUT NEAR THE IRRIGATION DITCH. COMMENTS: THE FINAL INSPECTION WAS DONE BY RAYMOND MERRY OF EAGLE COUNTY ENVIRONMENTAL HEALTH AND THE DESIGN ENGIN- EER ON 8/30/02. THE ENGINEER'S FINAL CERTIFICATION AND AS -BUILT DRAWING WERE RECEIVED ON 10/30/03 THIS SYSTEM IS LARGE ENOUGH TO ACCOMMODATE A FIVE BEDROOM RESIDENCE. ANY ITEM NOT MEETING REQUIREMENTS WILL B ORR INAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE - INSPECTION WHEN WORK IS COMPLETED. ENVIRONMENTAL HEALTH APPROV DATE: NOVEMBER 10, 2003 MAR-19-2002 04:21F FROM:ERGLE COJNT'Y ENV HEA 9703288788 T0:91970927985E F:1z5 Incomplete Applications Will NOT Be Accepted (Site Plan MUST be attached) ISDS Permit # c)-Z// Building Permit #, k— APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. O. BOX 179 EAGLE, CO 81631 Eagle (970)328-8755, Fax (970)328-0349, El Jebel (970)927-3823 * FEE SCHEDULE * APPLICATION FEE $350.00 * THIS FEE INCLUDES THE ISDS PERMIT, SITE EVALUATION (PERCOLATION TEST, * SOIL PROFILE OBSERVATION) AND FINAL INSPECTION * ADDITIONAL FEES MAY BE CHARGED IF A REINSPECTION IS NECESSARY, OR A * PRE -CONSTRUCTION SITE VISIT OR CONSULTATION IS NEEDED * REINSPECTION FEE $47.00, PRE -CONSTRUCTION SITE VISIT FEE $85.00 * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" ****•�***�**�r*,�**,��a�r*****,t�rw�r�rw+��s*�r*#x�r***rr*�*****,r****��a***�r,a***act**�**r**** PROPERTY OWNER: 1�/"�� /tT 4 EArcr_sol MAILING ADDRESS: 0313 SWa.'s C'A trg lei 4*a 6115AL-r el(oQ% pHON : ga-;L-lX3a APPLICANT/CONTACT PERSON: bAt/ E41C.KSaJ PHONE: _6W-/377 LICENSED SYSTEMS CONTRACTOR : �AC16 0ON�ttLk07)) J - PHONE : COMPANY/DBA: DREAG-6X C.ONST?2. ADDRESS: � ke 13` .8i95ACr 8i6�� PERMIT APPLICATION IS FOR: ('A NEW INSTALLATION ( ) ALTERATION { } REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description: LOT.1 ';.1t;•;A�5106-4 N,TI1/ ✓iEW c�)Np6UIV6r Tax Parcel Number: ass 000?a- Lot Size: Physical Address: 06IS' AIOUIV7 Llfk`OeA EC Je&76 P6,a�' BUILDING TYPE: (Check applicable category) t Residential/Single Family Number of Bedrooms { ) Residential/Multi-Family* Number of Bedrooms { ) Commercial/Industrial* Type *These .systems require design TYPE CF WATER SUPPLY: (Check { x} well ( ) Spring ( ) Publ ie Nam APPLICANT SIGNATURE : by ,661stereci Professional Engineer -yes ifi(iC applicable category) ( ) Surface (eornrnUNiTy Wr2L� �' � r11 AMOUNT PAID: �� RE CE CHECK # DATE: _ CASHIER: DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX: (970) 328-8788 TOLL FREE: 800-225-6136 www.eagle-county.com November 10, 2003 Dan and Cynthia Erickson 0373 Sopris Creek #2 Basalt, CO 81621 EAGLE COUNTY RAYMOND P. MERRY, REHS Director RE: Final of ISDS Permit #2211-02, Tax Parcel #2391-222-02-002. Property location: 0615 Mountain View Rd., Carbondale, CO. Dear Mr. & Mrs. Erickson: This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, i i Janet Kohl Eagle County Environmental Health Department ENCL: Educational Brochure Final ISDS Permit cc: files, November 2003 Chrono file OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX (970) 328-8788 TDD: (970) 328-8797 TOLL FREE: 800-225-8136 www.eagle-county.com EAGLE COUNTY, COLORADO Date: August 1, 2002 TO: Elkhorn Excavating FROM: Environmental Health Division Raymond P. Merry, REHS Director RE: Issuance of Individual Sewage Disposal System Permit #2211-02. Tax Parcel #2391-222-02-002. Property Location: 0615 Mountain View Rd., Carbondale, CO., Erickson residence. Enclosed is your ISDS Permit 42211-02, and a field copy of the engineer design stipulated on the permit. It is valid for 120 days, or for the duration of your current building permit for this property. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Please note any special requirements that may have been added to the design by this department. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County Environmental Health must also view the installation prior to back filling. Please call well in advance for your final inspection. Your TCO will not be issued until our office receives this certification from the engineer, and views the installation. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. Please notify this office if you have not been contracted to perform this installation. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files High Country Engineering, Scott Stevens OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 t-7-j�f October 23, 2003 RECEIVED OCT 2003 Ray Merry ENVIRONMENTAL Eagle County Department of Environmental HealthiEALTH DEPARTMENT P.O. Box 179 Eagle, CO 81631 RECEIVED RE: Erickson ISDS, Lot 1 Aspen Mountain View OCT 3 0 2003 I10E Project No. 2021041.0218 ENVIRONMENTAL Dear Ray, HEALTH DEPARTMENT The following letter is to confirm the engineer's inspection, of the revised septic system of the Erickson Residence at Lot 1, Aspen Mountain View, The design included a 2000- gallon concrete septic tank and 70 infiltrator absorption units. The trench configuration is As shown on the Plan. The five absorption trenches each have 14 infiltrator units. New piping f orn the houses and clean outs have been installed. blue board and berming have been installed near the proposed house where the piping is shallow and the portion under and witbizt 50-feet of the irrigation ditch has been encased in concrete. High Country Engineering Inc. (HCE) has performed three site inspections to observe the construction of the new ISDS. The field inspections have been documented, and High Country Engineo ing will provide photo documentation for the certification. Field measurements have been taken and the drawing bas been updated. With the above noted changes, the system has been completed with the intent of the original design. If you have any questions, or need additional information, please contact us. Respectfully, HIGH COUNTRY ENGINE Igo- r Neal, P,E, Principal Engineer Encl. cc: Dan. and Cynthia Erickson 1517 Blake Apeaua, Ste, 101 141nverness Drive East, Sta. D-136 Glenwood Springs, CO 81601 Englewood, CO 60113 phone 970 945-8676 -fox 970 945.2595 phone 303 925.0544 -A-v .103 925.0547 Orand,hincdon, CO80501 phone 970 858.0933 ■ fax 970 854-0173 OCT-30-2003 THU 12:46PM ID:EACLE COUNTY ENV HEALTH PACE:1 uu" vl vr- ""w vu.�)u ML I11UII WUMLU LIIUMLLRS11W rr1A LIU. JIu J40 LDDO OVERALL WIDTH r. uL CONCRETE PLACED ON Cvl�paea-ecA Soil TWO 51DES OF ENCASEMENT TO BE FORMED CONTINUOCONTJNUO LY WATER OR SEWER LINE SILEF VkS *SEE NOTE 16 FOR CONCRETE MIX DESIGN CONCRETE ENCASEMENT FOR WATER AND SEWER LINES N.T.S. REMOVABLE PVC CAP PJN15r1 6p a•. ��.5 n drill 4" RISER 4" COUPLING 4" SEWER LINE 4" PVC WYE CONCRETE ENCASE CLEANOUT 4" ABOVE ELBOW AND 4" BELOW PIPE. EXTEND CONCREIF 4" BEYOND EITHER SIDE OP' WYE CONNECTIONS. 45' SWEEP BEND +SEE NOTE 16 VOR CONCRETE MIX DESIGN E SWER CLEAN OUT DETAIL � CLEAN OUT A55F M f3t,Y N.T.S. 16. RECOMMENDED CONCRETE MIX: 1 RAC; (100 LOS.) TYPE I OR TYPE II PORTLAND CEMENT, 400 LBS. OF CONCRETE SAND AND GRAVEL, AND 20 1.13S. OF FRESH WATER. (1 PART CEMENT:4 PARTS SAND AND GRAVEL + 0.2 WATER) ° � HIGH COUNTRY ENGINEERING, INC. Darn AND GYNTinA ERICKSDN EAGLE COUNTY,SCALE: N, T.S. C0 ISDS.DWG ' - 1517 DL,6KE AWWI= 14 NVERW—%S DFM EA57 he-• SEINr=E Im Bi.Kt;E f5139 ERIGKSC3fJ MW000 SMNOS, CO 816M a4MLMM3, 00 80I13 DES. SLS CK: RDN FILE .�NO. ^� a Pw (ag) ms_aa7e Fu S saassa ENCASEMENT DETAILS ., ... SHEET III- FX070)945-2555 FX.f3WiH2S-054% I IDR. SLS IDATE: 07/31/021202-100 .00 ( 1 III TI 11 _­21 _'WAMD I.ICM MQ-E77OM Tn-Cnr-'l C f`I111A ITV CAII 1 UC7ni TU . Onf-ZE7.0 July 25, 2002 Ray Merry Eagle County Department of Environmental Health P.O. Box 179- Eagle, CO 81631 RE: Erickson ISDS, Lot 1 Aspen Mountain View HCE Project No. 2021041.0218 Dear Ray, We have made the revisions to the Erickson ISDS as per a telephone conversation with Laura Fawcett on Monday, July 22, 2002. We re -aligned the trenches to match the existing topography, added a Schedule 40 PVC sleeve to the building sewer located within 50-feet of the irrigation ditch, and revised the absorption area calculations based on the proposed flow rate. We have also specified concrete encasement of the proposed cleanout which is located within 50-feet of the irrigation ditch. If you have any questions or need further information regarding this project, please feel free to contact us. Respectfully, HIGH COUNTRY ENGINEERING, INC. Scott L. Stevens, E.I. Project Engineer Encl. cc: Dan Erickson, via fax 927-9866 RECEIVED JUL 2 5 2002 ENVIRONMENTAL HEALTH DEPARTMENT 1517 Blake Avenue, Ste. 101 14 Inverness Drive East, Ste. D-136 Glenwood Springs, CO 81601 Englewood, CO 80112 phone 970 945-8676 • fax 970 945-2555 phone 303 925-0544 • fax 303 925-0547 Grand Junction, CO 80501 phone 970 858-0933 • fax 970 858-0275 July 30, 2002 Laura Fawcett Eagle County Department of Environmental Health P.O. Box 179 Eagle, CO R1631 RE: Erickson Residence ISDS HCE Project No. 2021041.0218 Dear Laura, The proposed irrigation crossing of the building sewer line and water line is intended to be concrete encased at each end of the sleeved section. We will field verify that this is performed. Also, High Country Engineering will provide an as -built drawing to Eagle County of all of the installed components so that verification of minimum setbacks, concrete encasements, and relative items has been installed as designed. If you have any questions or need more information regarding this project, please feel free to contact us. Respectfully, HIGH COUNTRY ENGINEERING, INC. S tt L. S ev#ns,: E.I. Project Engineer cc: Dan and Cynthia Erickson, via fax 927-9866 1517 Blake Avenue, Ste. 101 14 Inverness Drive East, Ste. D-136 Glenwood Springs, CO 81601 Englewood, CO 80112 Grand Junction, CO 80501 phone 970 945-8676 • fax 970 945-2555 phone 303 925-0544 • fax 303 925-0547 phone 970 858-0933 • fax 970 858-0275 April 30, 2002 Dan Erickson Hepworth-Pawlak Geotechnical, Inc. 5020 County Road 154 Glenwood Springs, Colorado 81601 Phone: 970-945-7988 Fax: 970-945-8454 hpgeo@hpgeotech.com 0373 Sopris Creek Road, #2 Basalt, Colorado 81621 Job No. 102 280 Subject: Percolation Testing for Proposed Residence, Lot 1, Oak Ridge II, Eagle County, Colorado Dear Mr. Erickson: As requested, Hepworth - Pawlak Geotechnical, Inc., performed percolation testing at the subject site. The testing was done in accordance with our agreement for Professional Services to you, dated April 22, 2002. The subsoil study for foundation design will be completed when access to the building site is available. A Profile Pit and three percolation test holes were excavated on April 25, 2002 at the locations shown on Fig. 1. The subsoils exposed in the Profile Pit, below about one foot of topsoil, consisted of 21/2 feet of reddish brown sandy clay overlying light brown to white silty sand and gravel with basalt cobbles down to 81/2 feet. No free water was observed in the pit and the soils were slightly moist to moist. Percolation test holes were hand dug in the bottom of shallow backhoe pits and soaked with water on April 25, 2002. Percolation testing was conducted on April 26, 2002, by a representative of Hepworth - Pawlak Geotechnical, Inc. The percolation test results are summarized on Table I. Based on the subsurface conditions encountered and the percolation test results, the tested area should be suitable for a conventional infiltration septic disposal system. The percolation test were conducted in the silty sand and gravel soils underlying the reddish brown sandy clay. If you have any questions or need further assistance, please call our office. Sincerely, HEPWO PAWLAK GEOTECHNICAL, INC. Louis E. Eller Rev y: Daniel E. Hardin, P LEE/ksw attachments 120 N, 110 LOT 2 APPROXIMATE SCALE 1" = 60' 130 \ PROPOSED \ \ RESIDENCE 130 1 � \ EXISTING ` \ IRRIGATION - f \ DITCH P 3\ 0 \ �� ® \ \ \ OPEN P 2 PROFILE \ \ \ SPACE 0 PIT \ LOT 1 120 A P 1 \ 1 s 1 � 1 1 110 Mp � UNTq�� 11040 HEPWORTH—PAWLAK 102 280 LOCATION OF PERCOLATION TEST HOLES I Fig. 1 GEOTECHNICAL, INC. m HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE I PERCOLATION TEST RESULTS JOB NO. 102 280 HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN./INCH) P-1 42 15 water added 6 1 /4 . 5 1 /2 3/4 27 5 1/2 4 3/8 1 1/8 6 1/8 5 1/4 7/8 5 1/4 4 5/8 5/8 4 5/8 3 3/4 7/8 3 3/4 3 1/4 1/2 3 1/4 2 5/8 5/8 2 5/8 2 1/8 1/2 P-2 42 15 water added 5 3/8 4 1 /4 1 1/8 19 4 1/4 3 1 1/4 7 7/8 6 3/8 1 1/2 6 3/8 4 5/8 1 3/4 4 5/8 3 3/4 7/8 3 3/4 2 7/8 7/8 2 7/8 2 7/8 2 1 3/8 5/8 P-3 48 15 water added 7 1 /8 6 1 /4 7/8 33 6 1/4 5 3/8 7/8 5 3/8 5 3/8 6 5 3/8 5/8 5 3/8 4 3/4 5/8 4 3/4 4118 5/8 4 1/8 1 3314 3/8 3 3/4 3 3/8 318 Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on April 25, 2002. Percolation tests were conducted on April 26, 2002. The average percolation rate is based on the last three readings of each test. ISDS PERMIT # c,2 ,/i-0, PERCOLATION TEST EAGLE COUNTY ENVIRONMENTAL HEATLH Le i s l��l�s&I -PHSYSICAL ADDRESSV .)' U. _ LEGAL DESCRIPTION: Cte, MAILING ADDRESS: TYPE OF DWELLING: R5 F NUMBER OF BEDROOMS: TEST HOLES PRE-SOAKED: YES NO SOIL TIME WATER DEPTH INCHES OF FALL RATE PROFILE 01 mmmam mmmmmmmmm mmmmmmmmm mmmmmmmm mmmmmmmm mmmmmmmmm I mmmmmmmm off", mmmmmmmmm mmmmmmmmmm ommmmmmmmml TIME TO DROP LAST INCH: PERC RATE: MINIMUM LEACH FIELD SIZE: MINIMUM SEPTIC TANK SIZE: COMMENTS: ENVIRONMENTAL HEALTH SPECIALIST DATE (50-T! ISDs Permit # ` 04 Date-�--f— I3D& Final Inspection ComMletenesg Form Tank is .I0056 gal. Tank Material Tank. is is located ft. and 2320 degrees Tank is located ft. and degrees from Ipmummt IwWwrkl auk set level. k lids within 8" of finished grade. :��Size of field fts O units lineal ft. Technology .l S� �.- frTl� gcs4 Cleanout is installed in between tank and house(+ 1/100ft).A)d d6' There is a "T" that goes down 14 inches in the inlet and outlet of the t Iret outlet is sealed with tar•.,tape;. rubber gasket etc. k TLnx has two dtimpartments with the 1;a-.ger-.-:.cp paa tment closest to house. :. maeure: distance and relative direq"Qn,. to..-�i:eld. r� N§pth of fie! ft. AaS.. interface raked.- portals at the .end of each trench.. ::?Zr�/pro edistance to setbacks. Chambers properly installed as per manufacturer$ specifications. (Chambers latched, end plates properly installed, rocks 'removed from trenches, etc.) Type of pipe used for building sewer line leach field L-4 Other Inspection meets reauirements. Copy form to installer's file if recommendations for improvement Mere suggested. ACTION TAKEN: a Setbacks Well Potable House Property Lake Dry Tank Drain Water Lines line Stream Gulch Field 100 25 20 10 50 25 10 10 50 10 5 10 50 10 * 10 E*GbE- COURT --ENV. HEAUTH —.— ,(oe P.O. BOX 179 SHEET NO. EAGLE, CO 81631 CALCULATED BY CHECKED BY SCALE PRODOCTMI (Sin* Sheets) 2OS-1(Pd&dj /7�/® Ins.. Groton, Mass. 01471. To Oidet PHONE TOLL EPEE VIGR25-Mg OF DATE DATE dvL w 2� � � � \�� < %, \� y�� �^�~ ?. d�%�:�� ^ � � � � � ) z:,�¥ �\/� \y . »� \� � � . � � \� � � �\ � � \ \�f\��\��� ?� d������\��\,��\\ \». « ? < Am d d 2211-02 Tax #2391-222-02-002 JOB NAME, Lot #1, Filing 2, ERICKSON Oak Ridge II, Aspen Mt. View 0615 Mountain View Rd., Carbondale JOB NOAP- A/ 1 Af-A"nN • DATE�TAII DATE COMPLETED DATE BILLED Fill!�/. A 1 � Md A M.-I �J'Wr L FORM m, WON 1!I lillli,iliv.11 .� s l � NOWN � r � •� .. mw�, _ / d P, . Um - •_ •SUMMARY LRIN100, WE �iL s� � .r.. � � ♦ G�. Jai � TOTAL _■ _ TOTAL LABOR i F� I w mg IE� E -� [ . lull 1 � � � mm o • I f i 1 r ►���''i 76) �5� - ��3��a 7d 36 /3v Doz 2�0` St s .� n�7aGl� a ° O O yz� �� � , G�inc� e z " ri c?,1 %0 6 Ho Id T60 tt,� lr�tu-ev, x,�),Ild, v e,4 w 74 rd3v6 � 1� Recycled Content 10% post -Consumer 30 GRAPHIC SCALE 0 15 30 60 ( IN FEET ) I inch = 30 ft. OVERALL WIDTH CONCRETE PLACED ON COMPACTED SOIL 120 TWO SIDES OF ENCASEMENT TO BE FORMED CONTINUOUSLY WATER OR SEWER LINE SLEEVES *SEE NOTE 16 FOR CONCRETE MIX DES -'I CONCRETE ENCASEMENT FOR WATER AND SEWER LINES N.T.S. MATCH EXISTING GRADE MATCH EXISTING GRADE MATCH EXISTING DITCH WALL SLOPE MATCH EXISITING FLOWLINE E_:: PROVIDE 2—FEET OF COMPACTED BENTONITE AT DISTURBED CHANNEL SE -ION. z zz L N 6" SCH, 40 SLEEVE 4" PVC SEWER PIPE IRRIGATION DITCH CROSSING N.T.S. 4, .............. . . __ -------------- ..................... . ............ ....... ............... MoUNrq N yew R�qO REMOVABLE CAP CUT HOLE IN TOP OF INFILTRATOR UNIT FOR INSTA'_'_ATION OF INSPECTION WELL PIPE \//�\/� RIO SIDES \' \ O 12 `/�\/ O \\�� 4" 0 PERFORATED PIPE 36" INSPECTION WELL DETAIL N•T.S. NA'RAL BACKFILL t12" MIN. COVER 36" MAX. COVER / TRENCH BOTTCM_=_VEL NATURAL GROUND AND ROUGHEti=C z6' TRENCH CROSS �--)ECTI REMOVABLE PVC CAP FINISH GRADE —\ o.e op.Q o Q, O eO O �db O o VICINITY MAP SCALE: 1 "= 2000' NOTO ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE EAGLE COUNTY REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. FLOW FOR BED: 5 BEDROOMS * 2 PERSONS/BEDROOM * 75 GALLONS/PERSON/DAY IS: 750 GPD = AVERAGE DAILY FLOW, DESIGN FLOW = 1.5 * AVERAGE = 1125 GPD (Q) ***INCREASE BY 20% FOR USE OF GARBAGE GRINDER, Q= 1350 GPD*** SEPTIC TANK: MINIMUM TOTAL TANK SIZE: Q * 1 DAY/24 HRS * 30 HRS = 1688 GPD INSTALL ONE 2000-GALLON CONCRETE TANK WITH BAFFLE ***INSTALL EFFLUENT FILTER IN SEPTIC TANK OUTLET*** STANDARD ABSORPTION AREA: A = _ DESIGN FLOW APPLICATION RATE BASED ON PERCOLATION APPLICATION RATE TEST RESULTS OF 27, 19 AND 33 MPI. 1350 GPD = 2110 SF 0.64 PD USE OF STANDARD INFILTRATOR UNITS IN TRENCH CONFIGURATION: 50% REDUCTION- (2110 S.F.*0.50) ® 15.5 S.F./UNIT, 69 UNITS REQUIRED. INSTALL 5 ROWS AT 14 UNITS PER ROW. 3, CLEAN OUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100 FEET ALONG THE HOUSE SEWER. 4 THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS, PRIOR TO THE ABSORPTION AREA, TO PREVENT INFILTRATION. 5 TOPSOIL COVER MAY BE VARIED (WITH 1 FOOT MINIMUM) TO ALLOW LANDSCAPING. 6 INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN ONE-HALF FOOT OF FINAL GRADE. 7 LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. 8 PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION FIELD AREA USING DRAINAGE SWALES AS NECESSARY. 9 SOILS AND PERCOLATION INFORMATION PROVIDED BY H,P, GEOTECH, JOB #102 280, DATED APRIL 30, 2002. PERC RATES = 27, 19 AND 33 MPI. 1 THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT, PERMIT MUST BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL AND PROVIDE REPORT TO COUNTY. i' THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 12. SITE PLAN INFORMATION FROM SITE OBSERVATION, NO SURVEY WAS PERFORMED. INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS LESS THAN 5.0 FEET, 4 THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR TO BACKFILLING OF SYSTEM COMPONENTS. DESIGN OF ABSORPTION TRENCHES BASED ON SOIL PROFILE INDICATING 2' TOPSOIL OVERLYING SAND AND CLAY TO A PROFILE DEPTH OF 9 FEET, 16. RECOMMENDED CONCRETE MIX: 1 BAG (100 LBS.) TYPE I OR TYPE II PORTLAND CEMENT, 400 LBS. OF CONCRETE SAND AND GRAVEL, AND 20 LBS. OF FRESH WATER. (1 PART CEMENT:4 PARTS SAND AND GRAVEL + 0,2 WATER) 4" RISER OSULAL A080HPIM MIEMM 1 ABSORPTION LATERALS SHALL NOT EXCEED 100 FEET IN LENGTH, 4" MIN. CONCRETE ENCASE CLEANOUT 4" 4" ABOVE ELBOW AND 4" BELOW 2, THE BOTTOM OF EACH ABSORPTION TRENCH SHALL BE LEVEL. PIPE. EXTEND CONCRETE 4" COUPLING e OND EITHER SIDE OF WYE 3. DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND TRENCHES, AS ° ° CO N E e NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA, a 4" 45' SWEEP BEND O, 4, TRENCH LATERALS SHALL FOLLOW CONTOURS. 4" SEWER LINE e 12" $ °. ° 5. INSTALL INFILTRATOR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, ° a e d a *SEE NOTE 16 FOR ° S. TRENCH BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE SOIL SMEARS FJ�OW CONCRETE MIX DESIGN e m INCURRED DURING EXCAVATION. 'd' e e e 7, NO EXCAVATION OF ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER ABSORPTION AREA IS PROHIBITED a — INFILTRATOR UNIT 4" x 4" x 4" 4" 3. BOULDERS EXISTING WITHIN THE TRENCH SHALL BE EXCAVATED AND PVC WYE ��� BACKFILL SHALL CONSIST OF ONSITE SELECT OR PIT —RUN MATERIAL. CLEAN OUT ?, IN ALL TRENCH CONFIGURATIONS, SERIAL DISTRIBUTION SHALL BE USED TYP . SEWER CLEAN O U T D E TA I L ASSEMBLY INSTEAD OF EQUILATERAL DISTRIBUTION TO INCREASE SETTLING TIME AND PROTECT THE BACTERIAL B I O—MAT . N,T,S, 0. BEND IN TRENCH SHALL BE MADE WITH END PLATES AND 4"0 PVC OR VANUFACTURER'S PREFABRICATED BENDS. m z 0 w w Q 0 O z O Ln O Cl) V) z 0 1 J Q'-, (n of (D O O (n Iw— LEI W O Y Q -_j co U CO) 0 Z O Q N Z WE W o8 9 _Z W��� W W WIXL sFo0 Z to "- 5 Lma OZFf^ U �QOON Y8 = g m O Was I �0(L \0 w II__ in z C0 W 00 w J5 YQ V QZ UJo O w OF z Q Co CO CO H� cc Illm J� Z O �Z aw 0 J o U w CO fn Q z ow w QF- 0 O Z PROJECT NO, 2021041.0218 SHEET 1