HomeMy WebLinkAbout226 E Lakeside Trl - 194122401001INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 2208-02 BP NO. 14301 OWNER: DUNDEE REALTY USA LLC PHONE: MAILING ADDRESS: P.O. BOX 1593, AVON, CO 81620 APPLICANT: THOMAS J. KALLENBACH PHONE: 406-586-2289 SYSTEM LOCATION: 226 LAKESIDE TRAIL, WOLCOTT, CO TAX PARCEL NO. 1941-224-01-001 LICENSED INSTALLER:_ VAIL RESORTS DEVELOPMENT, JAMIE PAPPAS LICENSE NO. 45-02 PHONE: 970-845-2528 DESIGN ENGINEER: FLUIDYNE ENGINEERING, THOMAS J. KALLENBACH PHONE NO. 406-586-2289 INSTALLATION GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 5 BEDROOM RESIDENCE 1500 GALLON 2 COMPARTMENT SEPTIC TANK, 1000 GALLON 1 COMPARTMENT CONCRETE DOSING TANK AND A D- NITE TREATMENT TANK CONNECTED IN SERIES TO THE MAIN LEACH FIELD FOR THE LAKESIDE CLUSTER SYSTEM PERMITTED UNDER IS-2108-01. SPECIAL INSTRUCTIONS: INSTALL AS PER ENGINEER'S DESIGN REVISIONS DATED 6/21/02, WITH A CLEANOUT BETWEEN THE FIRST TANK AND THE HOUSE. CALL EAGLE COUNTY ENVIRONMENTAL HEALTH AND THE DESIGN ENGINEER FOR THE FINAL INSPECTION PRIOR TO BACK FILLING ANY PART OF THE INSTALLATION, OR WITH ANY QUESTIONS REGARDING THE INSTALLATION. THE BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS BEEN INSPECTED AND APPROVED. ENVIRONMENTAL HEALTH APPROVAL: RAYMOND P. MERRY DATE: DULY 9, 2002 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED 1500 GALLON 2 COMPARTMENT SEPTIC TANK, 1000 GALLON DOSING TANK, AND A D-NITE TREATMENT TANK, AS PER ENGINEER'S DESIGN. SEE AS -BUILT DRAWING FOR SYSTEM COMPONENT LOCATIONS. COMMENTS: THE ENGINEER'S FINAL CERTIFICATION WAS RECEIVED ON JUNE 13, 2003. THE AS -BUILT DRAWING WAS RECEIVED FROM THE LICENSED INSTALLER ON OCTOBER 20, 2003. THIS SYSTEM IS CONNECTED TO THE LAKESIDE CLUSTER SYSTEM LEACH FIELD. ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WH WORK ENVIRONMENTAL HEALTH APPROV DATE: MAY 11, 2004 JUlV-L`t-UL MVIN V3:LO rM rLuiDIAL VAA:7qUt7 oozo �D rlftuL --4-Ck tea: a�V r KJM: EPIGLE COUir i ,f ENV HEA 970328878e Tn! g149r_Inaninplete Number Of Redr•oomw Thin^A -- _- ��rw czesigi'i by a Registered p TYPE Or taa�w-- �,,,w__ _ r9�ea�� Qna3 E�igi��erwell APPL.tCNT riifa�i7hrnrmya q 7�9P it 5F it*ik*j:s� ISDS Permit 1r� 1 AFapd1.c.CAJLI0JXq FOR 1=1VI MAT EiFv1R0NMENTALHEALTH OFFICES- - EAGLEs Cot iYfnyTv u . eN, Eagle i 07y} 3aE=8?s fax .,.. x (970) 328_0'24q_ n! # - _. �ih: ��#±s'i##s:#see:k'irYrftetltiFtktk##i+ki�t4t+!� APPLICATION 'PRE -PRP.; $3.50cif n a00 * .qurT, Y'Svf1"TT-t+ nner .— `__ _ ="nsaaz �. 'SITE 4vALUATION -APERCOLATION mERm ADDITIONAL FEESMAYBE I !?nE ..�� , �.. p.�''''- .x Gam" .1CF I 1S,JDrbC a�..9Mgy- no z # # E:�CI®N RE1X5iM FEE $47.00 r PREP -: -- NEEi7ED ; .. _ - P E-C, i3 iciii.l.�ON a°F SP aT'a' E?FE $ng,nn 4 ".i5AULA}S COVMT; 'n��'iRto 'k1k'lallilk'&�e�kft'Ara�•�#�ytiE�r#�'#yYtk�ik�lEt*aFi'ir'ltrYtfY.lk'���'.'='az#tea#�. u # PROPERTY awNBR : r" LILI NG ADDRESS: .. r. �C a -rf r�- A x1LVCONTACT PERSON: ,tt 11 f� 4 nda PiDi�E : pf�(pyj@a9 gC . .1, 1-: C+'*T.TPTTS vaa �.-..-.....--_. it iL P f-•'- - d_IY16 1, !4 CONMACTUR:" 1. 1d1 1 i��f o t' ' 7�3. rt r .-�.L.�... :�•ia-si j ii%,i77;3?i: - __ ADDRESS: : AA ._._-.,.—,..��ic�c7ii�7eti4.1t9kilirltdtiE�k{t7k�k'ik9F'k7kitl&7Ftl4'�+.�'�'y,�7`�Yr#rie5?tYfrf*ylrekrFnAr a.n.i.r....-� ,_�--••�r:;e io riii[: tA) NEW TFT^,a�'Ai�ATIQN { j ALT$RAT�QLiT { ) REPn{ LfinhmrrrP� [')�' rsz3�r.r�.�r,.. i_�i -Ly ii��TT 77 7��TT� _ - '�--��"'-• +!S S'S'.LSt�iy]..�ST�fI aa.wiM3'F':FT-^TT�- R. ����VY Y1����rbd� - „ x i+vssi� SYSTEM : Physic dl Add,,-... F3UiLDING TYPE: ut���iai�Siaig Family { 'sj iResi--dential ji°RLll -ti- 'amp i r JE applicable Date: _- -7� " � a:iiir�irlY'k*�P*rt•*ttpF't4ii7t#•�•�rrx#�5tfttYlkyrylr**�t* AMOLIINT PAID: CHECK 7 DATE: Ti i;1i n11 _ f-.f-Ij Mi IM t.tk - +i 4L+R-I Ti-1- LY.l!_i L i -1 11 iki 5 "a+ M H i UCni t U Dcrf-_i-' 7 DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX: (970) 328=8788 TOLL FREE:800-225-6136 www.eaglecounty.us May 11, 2004 Dundee Realty USA, LLC P.O. Box 1593 Avon, CO 81620 EAGLE COUNTY RAYMOND P. MERRY, REHS Director RE: Final of ISDS Permit #2208-02, Tax Parcel #1941-224-01-001. Property location: 226 Lakeside Trail, Wolcott, CO., Dundee Realty USA, LLC Dear Property Owner; This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Janet Kohl Eagle County Environmental Health Department ENCL: Educational Brochure Final ISDS Permit cc: files, May 2004 Chrono file 500 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 DEPARTMENT OF ENVIRONMENTAL HEALTH (970)328-8755 FAX (970) 328-8788 TDD: (970) 328-8797 TOLL FREE: 800-225-8136 www.eagle-county.com EAGLE COUNTY, COLORADO Date: July 9, 2002 TO: Vail Resorts Development, Jamie Pappas Raymond P. Merry, REHS Director FROM: Environmental Health Division RE: Issuance of Individual Sewage Disposal System Permit #2208-02. Tax Parcel #1941-224-01-001. Property Location: 226 Lakeside Trail, Wolcott, CO., Dundee Realty USA, LLC property. Enclosed is your ISDS Permit #220802. Please obtain a field copy of the engineer design stipulated on the permit from the engineer. It is valid for 120 days, or for the duration of your current building permit for this property. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Please note any special requirements that may have been added to the design by this department. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County Environmental Health must also view the installation prior to back filling. Please call well in advance for your final inspection. Your TCO will not be issued until our office receives this certification from the engineer, and views the installation. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. Please notify this office if you have not been contracted to perform this installation. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files Fluidyne Engineering, Thomas J. Kallenbach OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 UU/ 101 LM rnl a,1L rnn 4VU 000 LJJJ IIUI JiU 4-H KAI HUI ToaIM1 Ca85 -OR nor] V5.5T QtE VOWTTrsa• JUUJ/UUJ VAIL R E S O R T$ DEVELOPMENT COMPANY June 11, 2003 Justi:u Buchanan Fluidyne 25 N. Willson Ave. Suite F Bozeman, MT 59715 Fait: 405-586-2335 Dear Justin: As you are aware we have C=Pleted the necessary tF, t g mquiremabts for the midence at Lot 57, Lakeside Trail, Red Sky R,atch. I have, aompieted the testing mquirments as tlstructed by Fluidnye lue. The, water -tightness test and veta$cation of oorrect operation of the force mamn pump is discussed below. 1000 gad 1SOG Galion Tank: A water tightness test was conducted over• a 2 day period fran% May d —May 8, 2003. There 'was no measurable crop in water level. Thus indicating no measureable leak in the Septic/Dose Tank. On may 5"' 2003 the farce main dosing, p=p was ttrtaaed on and it was vied that this Pump operated as desWged. The shared drawfield for this facility was previously inspected and certif led by Fluidyne Inc. as Part Of the Certi!60ate of Occul oy for the "Lakeside, Pumphoum' Buthroom, Please feel free to call me during the day if I can provide you with any fatlaer WOMAttm Thnk you, Vail R sorts Development Company amie .Pappas, Project Mamger VA14 pAesohrxr Wl 1;MW DevelapmeM Company • 137 Eenehr.m& Road . poet Office B= 959 + Avva, CalWAC10 0162OZ959 . (970) B46.2535 • fax (970) W-2555 • www vrdc.cam v2H - 0meckandke . K,eystonev . Bmet Q=k@ • Bachelor (inlchv . A n wh-.V + Aed Sky yduuA' - T/T ' d T2S ' OW 1W3Wd0-GA3Q 14,49T.2 E002 ' U " Wnf Ti IN-1 7-PM7 3 QT Ma-1 r-OM Tn- 3=af--i fZ' MI KM.' 3=+,11 i WJ Oi ru -7 F L U I D Y N E Scientists Engineers Inventors June 13, 2003 Eagle County Environmental Health Department Ray Merry, Director 500 Broadway P.O. Box 179 Eagle, CO 81631 Subject: Red Sky Ranch Lot 57 Certification of Completion Dear Ray: Please accept this letter as confirmation of completion of the. components serving the Red Sky Ranch lot 57. The individual system doses a pressure sewer for the Lakeside Place clustered system. The lot 57 components are comprised of the 1500-gallon septic tank, 1000-gallon dose tank, and the Eliminite ® unit. Vail Resorts Development Co. engineer Jamie Pappas, P.E, has tested the system. The certification process involved a leak test on the septic and dose tanks and a test to assure the transport of wastewater through the forcemain to the Lower Aspen Bluff Cluster (see enclosed). The inspection reveals the functionality of the system and its ability to support the treatment of wastewater. This letter serves as a certification of the system, that it is operative to provide wastewater treatment and that it was built in accordance with the approved plans. Please call with any questions. Respectfully, Adie Phillips for Thomas J. Kallenbach, P. E. Cc: Jamie Pappas _ �i F L U I D Y N E Scientists - Engineers - Inventors June 21, 2002 Ray Merry Eagle County Environmental Health 500 Broadway P.O. Box 179 Eagle, CO 81631 Re: Lot 57 Application for Attachment to Lakeside Place System Ray Merry: Included in this submittal is the application and supporting plan sheets for an ISDS Permit for Lot 57 of the Red Sky Ranch Subdivision. Please note that the tank configurations (septic, dose, and D-Nnite) shall be placed in outside of the building envelope. The building sewer must stub out from the building to maintain at least'/4" per foot of slope. 90 degree elbows should not be used in the building sewer configuration, instead 90 degree sweeps or 45-degree fittings will be acceptable. The submittal includes the following items: • Completed Application for ISDS Permit • Submittal Fee of 150$ • Site Plan • Wastewater System Detail Sheet Please call if you have any questions or need any further information. Sincerely, Adie Phillips Cc: Jamie Pappas JOB NAME_ 2208-02 Parcel 1941-224-02-002 Z- 0/ Lot 57 Red Sky Ranch Wolcott 6B LOCATION "-& BILL TO DATE STARTED DATE COMPLETED DATE BILLED -T-, C--D--U-eO It- k/ r xA1v'C'L"-e- 36 01 'AX0 ji 47t— ,%lf JOB COST SUMMARY TOTAL SELLING PRICE TOTAL MATERIAL 7 �171 TOTAL LABOR INSURANCE S) Iq - '4 SALES TAX f f MISC. COSTS TOTAL JOB COST GROSS PROFIT LESS OVERHEAD COSTS % OF SELLING PRICE NET PROFIT, JOB FOLDER Product 278 JOB FOLDER Printed In ".SA A B C D D-N1TE SYSTEM 2" EXTRUDED FOAM INSULATION t 28' DIA. LID / INSULATE BOTTOM OF LID ' d d QQ Q d Q FILTER FABRIC MIRAFI 14ON (OR :l11=1�jt�ll=1�11=11\�11\11=i1i=,��l;\\Ii`i=1 a s ° n d Q EQUIVALENT} _ G.4 4 4d a ! 4'0 SCH 40 PVC v c d• d a �. d d 4 4 TO SEPTIC TANK d TO 1 1/2' GRAVEL FILL AROUND ENTIRE TANK 2' d d d _ d• V G o a MINIMUM WIDTH D-NM UNIT PROVICED BY FLUIDYNE Inc. INSTALLED BY CONTRACTOR USA PATENT No. 5534147 & No. 5676828 D-NITS UNIT COMES COMPLETE AND READY TO INSTALL 1 LB BODE /DAY CONTRACTOR TO MAKE CONNECTION TO 4' SEPTIC TANK 1 1/2' SCH 40 PVC RETURN LINE AND 1 1/2' DOSE LINE. ALL OTHER PIPING FROM DOSE TANK. SHOWN ON D-NITE UNIT IS PROVIDED BY FLUIDYNE Inc. SLOPE TO DRAIN. 28' LD. RISER GREEN FIBERGLASS, INSULATED, 1000 GALLON PRECAST CONCRETE DOSE TANBC ' 1500 GALLON PRECAST CONCRETE DUAL COMPARTMENT SEPTIC TANK LOCKING LID (TYP OF ALL LIDS) FINISHED GRAD INSULATE BOTTOM OF LIDS (TYP) a i— O ZIP a - J � v d 4'0 SCH 40 PVC RETURN LINE FROM D-NITE DRAIN INSTALL TEE WITH 12' STUB DOWN 18' BELOW USE TEE OR LIQUID LEVEL CONCRETE BAFFLE I a 4"0 SCH 40 PVC FROM RESIDENCE SLOPE 1/4" PER FOOT e' d. a •e - Q - - A n - - - - • - SLOPE 1/4' PER FOOT 4"0 SCH 40 PVC 2" THICK EXTRUDED CLOSED CELL, SUBGRADE INSULATION (TIP) v d 4' WATER TIGHT JUNCTION BOX 1 1/2" PVC UNION DRILL 3 16"0 WEEP HOLE d 1 1/2"0 SCH 40 PVC ELBOW TO D-NITE UNIT SLOPE TO DRAIN 1 1/2-0 SCH 40 PVC HIGH WATER ALARM M PRESSURE SEWER ON co d - - PRESSURE SEWER OFF I- R ON/ OFF d- :4- -CONTRACTOR TO PROVIDE TANK BEDDING IN ACCORDANCE—/ WITH MANUFACTURER RECOMMENDATIONS. nesign Criteria Lot 57 Lakeside place Cluster 5g5tem acilitq: 5 [bedroom 51r4c Family Nome ( Lakeside place) aAcwater Generation for purpose of 5eptic Tarp, Volume Calculation: 2 people per bedroom X 7� gallons per person per dale X 5 bedralms X I �?07- peakinq factor-1125 gallons/ daq equate Septic Tark Size (to provide 30 hour retention time) : 112� gallons per day{/ 24 hours per day{-46,875I gallons per hour 46,87� gallon per hour X 3O hour retention time-1406 opllons eptic Tank 517e In V6510n: 1 �700 gallons a5-Eewater 6eneration: �72�7 ga1lon5 ( Approved Value from Sate of Cdor ado 5ite Approval proce55) akeside place Cluster Absorption Area Credit: 4�2 0 5a, ft, ( via 140 chambers) ' Anticipated Absorption Credit Consumed bq Fach Lot: �525 gallons per date/ 0.69 gallons per dais per 5a, ft, 471 5q, ft. .emaining ion Credits After Lot 57 Hxku : 3869 5g, ft, H � H -LOAT WITCH d O T d CV rD If i CV I .. Ad GRUNDFOS KP 250 SUBMERSIBLE EFFLUENT PUMP TO D-NITE UNIT INSTALL "PIGGY -BACK" FLOATS T RECIRCULATION PUMP FOR LOW WATER CUT-OUT GRUNDFOS KP 250 SUBMERSIBLE EFFLUENT PUMP TO PRESSURE SEWER 1 1/2 . 0 SCH. 40 PVC DOSE LINE FROM DOSE TANK -iYMAL PIS SEWER I PRESSURE SEWS BENCH DETAIL GRUNDFOS KP 250 SUBMERSIBLE EFFLUENT PUMP GRUNDFOS KP 250 SJBMERSIBLE EFFLUENT PUMP 0 00 RAW SEWAGE LINE FROM RESIDENCE FORCEMAIN TO 4' 1000 GALLON PRECAST PUMP STA110N 1500 GALLON PRECAST CONCRETE DOSE TANK C DETAIL C6.0 SCALE: 3/4`1' PIPE BEDDING MUST BE FREE OF LARGE ROCKS, SHARP ROCKS, TREE STUMPS, LOGS, & OTHER UNSUITABLE DEBRIS. MIN 2" PIPE BEDDING MATERIAL OVER INSULATION /— 4' THICK BY W" WIDE 25 psi / EXTRUDED INSULATION BOARD (AASHTO SPEC POLYSTYRENE, M230-70) 8' LENGTH MINIMUM WHERE PIPE IS LESS THAN 6.5' DEPTH AND UNDER DRIVEWAYS PIPE 4' CLEAN GRAVEL Z/_OR SAND ,/-4' CLEAN GRAVEL OR SAND 4" SCH 40 PVC SLEEVE UNDER DRIVEWAYS UNDISTURBED SOIL 0 u z in C6 LOT 57 NOTED SEPTIC TANK: 1500 GALLON PRECAST CONCRETE SEPTIG TANK DOSE TANK: 1000 GALLON PRECAST CONCRETE DOSE TANK D-NITE UNIT: PROPRIETARY NITROGEN REMOVAL SYSTEM. SUPPLIED BY FLUIDYNE Inc_ USA PATENT No. 5534147 AND No. 5676828 DOSE PUMP: GRUNDFOS KP 250 SUBMERSIBLE EFFLUENT PUMP DOSE PUMP CONTROLS: SIMPLEX CONTROL PANEL EQUIPPED WITH, AUDIBLE / VISUAL HIGH WATER ALARM RECIRCULATION PUMP: GRUNDFOS KP 250 SUBMERSIBLE EFFLUENT PUMP RECIRCULATION PUMP CONTROLS: SUPPLIED BY FLUIDYNE Inc. DRAINFIELD FLOAT ASSEMBLIES 3 ANCHOR MINI -FLOATS, OR EQUIVALENT 1. PVC TO BE JOINED W/ PRIMED SOLVENT/CEMENT WELD JOINTS. PRIMER MUST IMPART A SALIENT COLORATION TO THE COMPONENTS BEING CEMENTED. FITTINGS PRIMED W/ COLORLESS PRIMER WILL BE REJECTED BY THE ENGINEER AND REPLACED AT THE CONTRACTORS EXPENSE. 2. CONTRACTOR TO PRESSURE TEST SYSTEM IN PRESENCE OF THE ENGINEER. 3. SUBSTITUTIONS TO THE DESIGN ARE TO BE EVALUATED BY FLUIDYNE. 4. CONTRACTOR TO TEST SEPTIC TANK & DOSE TANK FOR WATERTIGHTNESS. ANY MEASURABLE WATER LOSS IN A 24 HR PERIOD WILL BE REJECTED. 5. SLOPE ALL PIPES TO DRAIN. A 20 10 0 20 40 60 80 SCALE 1'= 20' CONTOUR INTERVAL 2 FEET - - f . r LOT 58 0� '; . JOUFLAS RANCHES, INC. _�-