HomeMy WebLinkAbout21900 Hwy 6 - 193924401003INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 2186-02 BP NO. 14323 OWNER: TOM AND MARY JO RODENO PHONE: 303-688-8477 MAILING ADDRESS: 40 BANTALA PLACE, CASTLE ROCK, CO 80104 APPLICANT: DAVID MINICK PHONE: 970-904-5066 SYSTEM LOCATION: 21900 HIGHWAY 6, EAGLE, CO 81631 TAX PARCEL NO. 1939-244-01-003 LICENSED INSTALLER: J.A. BASKINS CONSTRUCTION LICENSE NO. 53-02 PHONE: 970-926-3748 DESIGN ENGINEER: LKP ENGINEERING, LUIZA PETROVSKA PHONE NO. 970-926-9088 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 3 BEDROOM RESIDENCE 1000 GALLON 3 COMPARTMENT SEPTIC TANK WITH AN ELECTRIC LIFT STATION, 868 SQUARE FEET OF ABSORPTION AREA CREDIT, VIA 28 INFILTRATOR UNITS. AS PER ENGINEER'S DESIGN DATED APRIL 19, 2002. SPECIAL INSTRUCTIONS: INSTALL AS PER ENGINEER'S DESIGN WITH A CLEANOUT BETWEEN THE TANK AND THE HOUSE INSPECTION PORTALS IN EACH TRENCH, AND FOR EVERY 100 FEET OF EFFLUENT LINE. RAKE ALL TRENCH SURFACES TO PREVENT THE SMEARING OF SOILS AND DO NOT INSTALL IN WET WEATHER. BE SURE TO MAINTAIN ALL APPLICABLE SET BACK REQUIREMENTS. CALL EAGLE COUNTY ENVIRONMENTAL HEALTH AND THE DESIGN ENGINEER FOR THE FINAL INSPECTION PRIOR TO BACK FILLING ANY PART OF THE INSTALLATION OR WITH ANY QUESTIONS REGARDING THE INSTALLATION. THE BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS BEEN INSPECTED AND APPROVED. ENVIRONMENTAL HEALTH APPROVAL: WILLIAM CARLSON DATE: JUNE 11, 2002 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 899 SQUARE FEET (VIA 29 INFILTRATOR UNITS AS PER ENGINEER'S DESIGN ) INSTALLED 3 COMPARTMENT CONCRETE SEPTIC TANK: 1000 GALLONS IS LOCATED 280 DEGREES AND 19 FEET INCHES FROM THE FIRST CLEAN -OUT ON THE WEST SIDE OF THE HOUSE. COMMENTS: THE FINAL INSPECTIONS WERE DONE BY VICTOR CROCCO OF EAGLE COUNTY ENVIRONMENTAL HEALTH AND THE DESIGN ENGINEER ON 4/29/03. THE ENGINEER'S FINAL CERTIFICATION AND AS -BUILT DRAWING WERE RECEIVED ON 6/5/03. THIS SYSTEM IS LARGE ENOUGH TO ACCOMMODATE A THREE BEDROOM RESIDENCE. ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. _ - - ^ ENVIRONMENTAL HEALTH APPROVAL �, ` DATE: JUNE 9, 2003 incomplete Applications Will NOT Be Accepted (Site - Plan MUST be attached) ISDS Permit # 2-136, —(,? j___,- Building Permit # APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT' ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. O. BOX 179 EAGLE, CO 81631 Eagle (970)328-8755, Fax (970)328-0349, E1 Jebel (970)927-3823 **************************************************************************** * FEE SCHEDULE * APPLICATION FEE $350.00 * THIS FEE INCLUDES THE ISDS PERMIT, SITE EVALUATION (PERCOLATION TEST, * SOIL PROFILE OBSERVATION) AND FINAL INSPECTION * ADDITIONAL FEES MAY BE CHARGED IF A REINSPECTION IS NECESSARY, OR A * PRE -CONSTRUCTION SITE VISIT OR CONSULTATION IS NEEDED * REINSPECTION FEE $47.00, PRE -CONSTRUCTION SITE VISIT FEE $85.00 * MAKE ALL..REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" **************************************************************************** PROPERTY OWNER: VO fRODr1✓O MAILING ADDRESS: `�'� iL� i'.�fL�4 /�L/�tc' C46;'Af RLr4 rt? olore PHONE: Z303-4W-;YV7;? APPLICANT/CONTACT PERSON: PHONE: q[%qts-y", -LICENSED SYSTEMS CONTRACTOR: ­ 04-Ck' 81wel .s PHONE: q,26--C75,ef COMPANY/DBA: Co-vsf_ ADDRESS: *************************************************************************** PERMIT APPLICATION IS FOR: (ANEW INSTALLATION ( ) ALTERATION ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description: L6_ ,3 RQ> Almn-T4,,: t&f"tl q Tax Parcel Number: 193 9 `14L/- 61 - �(� Lot Size: Physical Address: ::D901 11S,, 4&,Z 6 Ce BUILDING TYPE: (Check applicable category) (-Y Residential/Single Family (' ) Residential/Multi-Family* ( ) Commercial/Industrial* Number Number Type _ of Bedrooms 3 of Bedrooms *These systems require design by a Registered Professional Engineer TYPE OF WATER SUPPLY: (Check applicable category) ( 'Well ( ) Spring ( ) Surface ( ) Public Name of nSupplier: APPLICANT SIGNATURE: Date: �k�k*�F�c**ir**�F�t�c�k*�t**iric**ic*�c*ic*9c****ic*ic**icicic/�t**ic*�t�c**�cic�r**�Ficiric*�t�t*ic*******�t9c*fir AMOUITT PAID: 0ou RECEIPT ##-: DATE:lo��lDa-- CHECK # : CASHIER: DEPARTMENT OF ENVIRONMENTAL HEALTH (970)328-8755 FAX: (970) 328-8788 TOLL FREE:800-225-6136 www.eagle-county.com June 10, 2003 Tom and Mary Jo Rodeno 40 Bantala Place Castle Rock, CO 80104 EAGLE. COUNTY RAYMOND P. MERRY, REHS Director RE: Final of ISDS Permit #2186-02, Tax Parcel #1939-244-01-003. Property location: 21900 Highway 6, Eagle, CO. Dear Mr. & Mrs. Rodeno; This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Janet Kohl Eagle County Environmental Health Department ENCL: Informational Brochure Final ISDS Permit cc: files OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 DEPARTMENT OF ENVIRONMENTAL HEALTH (970)328-8755 FAX (970) 328-8788 TDD: (970) 328-8797 TOLL FREE: 800-225-8136 www.eagle-county.com EAGLE COUNTY, COLORADO Date: June 11, 2002 TO: J.A. Baskins Construction FROM: Environmental Health Division Raymond P. Merry, REHS Director RE: Issuance of Individual Sewage Disposal System Permit #2186-02. Tax Parcel #1939-244-01-003. Property Location: 21950 Highway 6, Eagle, CO., Rodeno residence. Enclosed is your ISDS Permit #2186-02. Please obtain a field copy of the engineer design stipulated on the permit from the engineer. It is valid for 120 days, or for the duration of your current building permit for this property. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Please note any special requirements that may have been added to the design by this department. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County Environmental Health must also view the installation prior to back filling. Please call well in advance for your final inspection. Your TCO will not be issued until our office receives this certification from the engineer, and views the installation. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. Please notify this office if you have not been contracted to perform this installation. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files LKP Engineering, Luiza Petrovska OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 LfAI LI YtAlI`ILLIA11YL1 11Y11 rHur— U1 S LKP-.. Engineedn% 1UC- CIVU-JGEO TECHNICAL May 25, 2003 Tom and Mary Jm Ro&00 2901 Walnut Street Denver, CO 80205 Dear Tom & Mary Jo: RE: Inspection of Septic Systems Installation. Lot 3, Red Mountain Ranch piling No. 4 21900 U.S. Iligllway 6, Eagle County, Colorado project No. 20239 - Permit No. 2196-02 At the request of Jack Baskins, on April 2% 2003, we visited th p onsstruct our site n Lo w9Red Mountain Ranch, 21900 U.S.1tli&way 6, Eagle County, Colorado. The to observe the installation of the septic system. They installed the system in overall compliance with the septic system design, Drawing No. 202398D.DWG, dated September 17, 2002. They installed a 1000-gallon, three compartments, precast, a coacrete, septic tank. In the last compartment of the septic tank, they installed a Goulds Model 3871 Pump. 'Each of the three access openings, had three, one -foot risers on it. We recommeaded that the riser over the conipartment with the pump be replaced with a cone -shaped riser for ease of maintenance for the pump. Building sewer lines were connected to the septic tank from four locations on the building. Two from the garage wing, one, south from the maim entry and one north from it, as shown, on the attached as - built sketch. Cleanouts were installed at each exit point near the house as shown on the sketch. The effluent line from the pump tank to the first infiltrator of the tap trench was a total distance of 235 feet. The effluent line was 3-inch diameter sch40 pve. The pump was sized to have four doses with 169 gallons per close. The dosing, the floats function anal the alarms will be tested by at a later date and a letter will be submitted to us. Based on Jack Baskins the alarm was installed in the garage. Tatty -nine, Standard Infiltrator Chambers were installed in three trenches, as shown on the attached sketch. The trench closest to ITi&WaY 6 had nine infiltrators and it had a perforated pipe suspended from the top of the chambers, the next trench had I I and the lowest trench had 9 i nflltrators. The infiltrators were connected with serial distribution(. In the first and last infiltrator of each trench, inspection ports were installed. Horizontal distance :from center to center of the trenches, was 10 feet or more. The depth of the trenches was no more than 36 inches, If you batre any quest erns, please do not hesitate to call. Sincerely, W'9� �uial xgwM1 '��F .% LIKP Engineering, 'w%° � � u Luiza Petrovska, PE s « President ��1� �09�°,� cc: Ms, Latuu Fawcett, Eagle County Environmental Healtb Division, fax: 329-0349, Dave Muriel: at 926-1029 Enclosure C:1Documents and Settings\Luiza Petrovska My DoeumontslWPI0-LKP1202390Sx-puwp.wpd P-0. Box 2837, F',dwards, CO 81632, (970) 926-9089 Tel, (970) 926-9089 Fax TIIhl-a-PPP7 wi=i"1 P7-P1ahl Tn � rIllIWTV GNlI WP:aI TW pares=-1 LrNi LI iu1 iYLGfN 11 iu 11v- f HIIG U.4 P-Q, Box 2837, Edwards, CO 81632, (970) 926-9088 Tel, (970) 926-9089 Fax TI 11.i_d_�WW27 im=n M7- Mh:30 rS Trt- COr-1 ♦= rni IWTV MA i W- 01 T--1 pnrU: - p LKP ENGINEERING, INC. P.O. Box 2837 Edwards, CO 81632-2837 (970) 926-9088 Fax (970) 926-9089 PERCOLATION TEST RESULTS Client: Tom & Mary Jo Rodeno Location: Lot 3, Red Mountain Ranch 2801 Walnut St. Filing No. 4 Denver, CO 80205 21900 U.S. Highway 6 Eagle County, Colorado Project No.: 20239 P-1 P-2 P-3 TIME/DEPTH 17-8/ 16" 27-2/ 16" 16" 10 8" 2" 7-2/16" 1-10/16" 5" 2-8/16" 10 10" 2" 8-12/16" 1-10/16" 6-12/16" 1-12/16" 10 11-8/16" 1-8/16" 10-8/16" 1-12/16" 8-4/16" 1-8/16" 10 13" 1-8/16" 12-4/16" 1-12/16" 9-4/16" 1" 10 14" 1" 13-4/16" 1" 10-4/16" 1" 10 15" 1" 14-4/16" 1" 11-4/16" 1" 10 16" 1" 15-4/16" 1" 12-4/16" 1" PERC RATE 10 MINANCH 10 MINANCH 10 MIN/INCH AVG PERC 10 MPI Average Percolation Hole Diameter: 12 Inches Holes Dug and Presoaked: April 1, 2002 Test Run: April 2,2002 By: Peter Petrovski Soil Profile: 0-2'- Topsoil 24- Reddish -brown, silty sand 4-5.5'- Reddish -brown, sandy gravel 5.5-8.5'- Reddish -brown, silty sand No ground water encountered LKP ENGINEERING, INC. P.O. Box 2837 Edwards, CO 81632-2837 (970) 926-9088 Fax (970) 926-9089 PERCOLATION TEST RESULTS Client: Tom & Mary Jo Rodeno Location: Lot 3, Red Mountain Ranch 2801 Walnut St. Filing No. 4 Denver, CO 80205 21900 U.S. Highway 6 Eagle County, Colorado Project No.: 20239 P-1 P-2 P-3 TIME/DEPTH 17-8/16" 27-2/16" 16" 10 8" 2" 7-2/16" 1-10/16" 5" 2-8/16" 10 10" 2" 8-12/16" 1-10/16" 6-12/16" 1-12/16" 10 11-8/16" 1-8/16" 10-8/16" 1-12/16" 8-4/16" 1-8/16" 10 13" 1-8/16" 12-4/16" 1-12/16" 9-4/16" 1" 10 14" 1" 13-4/16" 1" 10-4/16" 1" 10 15" 1" 14-4/16" 1" 11-4/16" 1" 10 16" 1" 15-4/16" 1" 12-4/16" 1" PERC RATE 10 MIN/INCH 10 MIN/INCH 10 MIN/INCH AVG PERC 10 MPI Average Percolation Hole Diameter: 12 Inches Holes Dug and Presoaked: April 1, 2002 Test Run: April 2,2002 By: Peter Petrovski Soil Profile: 0-2'- Topsoil 24- Reddish -brown, silty sand 4-5.5'- Reddish -brown, sandy gravel 5.5-8.5'- Reddish -brown, silty sand No ground water encountered ZSDS P8rmit # 21 % b ._ ()2 Date -IL 2-0 -D T S Final Ina�act oa • Q=Ietenenn Fot'm NNA- Tank is gal. Tdmk Material ,4 Tank is located ft. and degrees front LLA-Tank is located ft. and degrees from Tank set level. Tank lids within S" of finished grade. size of field ft; units _ lineal ft. Technology Ve Ve cleanout is installed in between tank and house(+ l/lOOft). There is a "T" that goes down 14 niches in the inlet and e outlet of the tank. Inlet. and outlet is sealed with tar:tapei, rubber gasket etc. _ T ring t*xo :e mtpartments with the.;AAkWe .<,CQMPartment closest to the house_ _•Xsaa=e; distance and relative di-repul _ Depth of field. ft. Soil interface raked. Inspection portals at the .end of each trench_. Proper distance to setbacks_ Chambers properly installed as per manufacturer$ specifications. (Chambers latched, end plates properly installed, rocks 'removed from trenches, etc.} Type of pipe used for building sewer line �- , - �' leach field Other 1 Inspection meets rMMirements .7- 1 Copy form to installer's file if recommendations for improvement were suggested. ACTION TAKEN: �J d A) e-- Setbacks Well Potable House Property Lake Dry Tank Drain Water Lines line Stream Gulch Fied 100 25 20 10 50 25 10 10 50 10_.t ID 50 10 * 10 Two 7R� nil �IIIQ�Qn ��?eteaess nose _ Task is �70 O gal. Tale Materf.al �,�, e ;,. �, �-s, e.,, 5.. a r cc ;, ae�, e to �K Task, is located cL_f t. and 0 eel � ► +'-4 c te-c e bammul•m s..a..ew Tank is located _ft. and ___degrees frost v Tank set level . Tank .lids within so of finished grade. r l se rs g d dQ d ✓ Size of field � ft= _�-�units -- lineal ft. �chnolow S �- • � � a � r. � � kr � � nR: _ . Other inspection meets Li ep�P CC�n�rac�tla G„tl,r�o� qrG be it7 3b`�_p�, c $ pie �r.c�i_ee,'L rani Copy .fors to installer's file if recommendations for improvement sere muggested. ACTION TAKEN: IV e, tics setbacks well Potable Lines House Property line Lake Stream Dry Tank Brain Gulch Fi e d I00 2r5 20 10 50 25 10 1 t �06 7 ebb 50 1O v 10 50 10 * 10 JM A '- -- OUNTR -- FENV UkLTH ; lfr - 5 CY P.O. BOX 179 EAGLE, CO 81631 ............. ....... . .............. ... . ....... . . ......... ............. .......... ... ...... ...... .. .. ............. .......... ........ . ... jso5l'2-i,66 Lo*3 P,-k HI Rr SHEET NO. CALCULATED BY_ IZ-.�L DATE - b -- 0 CHECKED BY V (Z F, V C C DATE .rl Up 05 9 ...... ..... ... ....... . .......... ....... .. .. : . ...... .... .. ......... ..... .... .. . ........ ......... .. ....... ... .... .. .. . ..... ..... .. .. . ......... .. . ...... . ............. . .. ........ .. ... ..... . ... ........ . . ........ ... .. .. .. ..... ........ .. .. P.O. BOX 179 SHEET Ha CF EAGLE, CO 81631 CAU ULATED13Y DATE CHECKED BY DATE ,A t F€rc 4uFr . ' t EE' int•-J� t x ) . i 1 i F ?�05O PROOUCI M I Sled+ Sheen) 24,1 IEw" ®ES k- Gm1 . Mu%. DIM, Fo 0,0,, PHONE NLL FACE 1 BOO7i5-67B0 2186-02 Tax#1939-244-01-003 JOB NAME_ Lot #3, Red Mt Ranch RODENO 21900 Hwy 6, Eagle JOB NO. P " JOB FOLDER Printed In US.A. N (- 5^ Q 17 l .N 4 C s� i° t i C rt, "� c V'�J C( f9 i c/ a S e iZ U� \- 1 RecyCled Content 10% Post -Consumer __ _ _ _ v - - _ - -- - - _ - — T � -_- - - _ - - _ - _ _ -_ � - � - -- - a I' t i� -ti � - _ r tf = = - = - - _ --- - = -_ = _ - t ��_ - -_ - - _ _ -_ -: - - E, �- _ i _ - _ - .� - - _ _ _ �z _ _ _ _ _ _ _ f - - � - .. _ _ - - - _ _ _ __ -_ - - _ -_ } -- _ - - _ _ - - _- - __ _ _ - -_ ., � _ r- � � - - - _ .. _ y. _ _ - _ _ - - _ - - _ - _, ._ _ - _ - _ _ _ - - - _ - _ _ - -- _- _.__ f .�. - - = - - - � - . � _ - - - - -