HomeMy WebLinkAbout1021 Green Meadow Dr - 239121402005INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 2183-02 BP NO. 14154 OWNER: GLENN AND DURELLE MONTGOMERY PHONE: 970-704-0186 MAILING ADDRESS: 436 PASEO DRIVE, CARBONDALE, CO 81623 APPLICANT: SAME PHONE: SYSTEM LOCATION: 1021 GREEN MEADOW DRIVE, CARBONDALE, CO TAX PARCEL NO. 2391-214-02-005 LICENSED INSTALLER: KEITH McLAREN LICENSE NO. 64-02 PHONE: 970-963-5589 DESIGN ENGINEER: HIGH COUNTRY ENGINEERING, DEREK WALTERS PHONE NO. 970-945-8676 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 4 BEDROOM RESIDENCE 1250 GALLON SEPTIC TANK, 2250 SQUARE FEET OF ABSORPTION AREA CREDIT, VIA 95 INFILTRATOR UNITS IN A BED CONFIGURATION, AS PER ENGINEER'S DESIGN DATED 4/5/02. SPECIAL INSTRUCTIONS: INSTALL AS PER ENGINEER'S DESIGN, WITH CLEANOUTS BETWEEN THE TANK AND THE HOUSE AND EVERY 100 FEET OF EFFLUENT LINE LEADING TO THE LEACH FIELD. DOUBLE SLEEVE THE EFFLUENT LINE WITH SCHEDULE 40 SIX INCH PVC PIPE FROM THE TANK OUTLET TO THE BED HEADER. RAKE ALL BED SURFACES TO PREVENT THE SMEARING OF SOILS, AND DO NOT INSTALL IN WET WEATHER. BE SURE TO MAINTAIN ALL APPLICABLE SET BACK REQUIREMENTS. CALL EAGLE COUNTY ENVIRONMENTAL HEALTH AND THE DESIGN ENGIN- EER FOR FINAL INSPECTION PRIOR TO BACK FILLING ANY PART OF THE INSTALLATION, OR WITH ANY QUESTIONS REGARDING THE IN- STALLATION. THE BUILDING CERTIFICATE OF OCCUPANCY WILIj NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS BEEN INSPECTED AND APPROVED.. ENVIRONMENTAL HEALTH APPROVAL -,DATE: MAY 20, 2002 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 1430 SQUARE FEET (VIA72 INFILTRATOR UNTTS DF.STGN 6-12-09 ) INSTALLED CONCRETE SEPTIC TANK: 1500 GALLONS IS LOCATED 80 DEGREES AND 14 FEET 8 INCHES FROM THE CLEAN —OUT ON THE EAST SIDE OF THE HOUSE, TO THE 1st COMPARTMENT OF THE TANK COMMENTS:THE FINAL INSPECTIONS WERE DONE BY RAYMOND MERRY OF EAGLE COUNTY ENVIRONMENTAL HEALTH AND THE DESIGN ENGINEER ON JULY 12, 2002, THE FINAL CERTTFTCATTON WAS RF.CFTVED ON .TTTT,Y 12, 20 THIS SYSTEM. IS ONLY LARGE ENOUGH FORIBEDR00MS. NO FUTURE BEDROOMS WILL BE ALLOWED IN BASEMENT. ANY ITEM NOT MEETING REQUIREMENTS WILL BE C REF PP OVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. ENVIRONMENTAL HEALTH APPROV DATE: AUGUST 2, 2002 Incomplete Applications Will NOT Be Accepted ,(Sitw Plan MUST be attached) ISDS Permit # _ Building Permit # ILItJ APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. 0. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (El Jebel) * FEE SCHEDULE * PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 * SIZING AND SITE VISIT FEE $85.00 (WHEN ENVIRONMENTAL HEALTH SIZES THE * SYSTEM USING YOUR SOILS REPORT) * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" ************************************************************************** PROPERTY OWNER: -t pL-DK!F f MAILING ADDRESS: _Q10 . ! IL 2.3 PHONE: -7oC4-01 APPLICANT/CONTACT PERSON: Mmt=-rX6en^10K�F PHONE: g" 2&1 LICENSED SYSTEMS CONTRACTOR: �.( � iZ/ PHONE: COMPANY/DBA: ADDRESS: *************************************************************************** PERMIT APPLICATION IS FOR: ( NEW INSTALLATION ( ) ALTERATION ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description: L.DT to ':51Q'9--t5 tSc2t5• Tax Parcel Number: 2��� Z�� OZODrj Lot Size: �J• t Ate• Physical Address: _' c�2 l tz � M�F— Do w Qvx'Ji-- BUILDING T E: (Check applicable category) ( Residential/Single Family Number of Bedrooms_ ( ) Residential/Multi-Family* Number of Bedrooms ( ) Commercial/Industrial* Type *These systems require design by a Registered Professional Engineer TYPE OF WATER SUPPLY: (Check applicable category) ( ) Well ( ) Spring ( ) Surface ( )yPublic /Name of Su pliers ILO MM ot-z k"� APPLICANT SIGNATURE: Date: AMOUNT PAID: <��� r� RECEIPT # : G'/ DATE: % 6 CHECK #: / CASHIER: DEPARTMENT OF ENVIRONMENTAL HEALTH (970)328-8755 FAX (970) 328-8788 TDD: (970) 328-8797 TOLL FREE: 800-225-8136 www.eagle-county.com EAGLE COUNTY, COLORADO August 2, 2002 Glenn and Durelle Montgomery 436 Paseo Drive Carbondale, CO 81623 Raymond P. Merry, REHS Director RE,: Final of ISDS Permit #2183-02, Tax Parcel #2391-214-02-005. Property location: 1021 Green Meadow Drive, Carbondale, CO. Dear Mr. & Mrs Montgomery: This letter is to inform you that the above 'referenced ISDS Permit has been inspected and finalized:' Enclosed is a copy to retain for your records.. This permit does not indicate compliance with any other Eagle County requirements: Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Janet Kohl Eagle County Environmental Health Department ENCL: Informational Brochure Final ISDS Permit cc: files OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX (970) 328-8788 TDD: (970) 328-8797 TOLL FREE: 800-225-8136 www.eagle-county.com EAGLE COUNTY, COLORADO Date: May 20, 2002 TO: Keith McLaren FROM: Environmental Health Division Raymond P. Merry, REHS Director RE: Issuance of Individual Sewage Disposal System Permit No.2183-02. Tax Parcel # 2391-214-02-005. Property Location: 1021 Green Meadow Drive Carbondale, CO., Montgomery residence. Enclosed is your ISDS Permit No. 2183-02 and a field copy of the engineer design stipulated on the permit. It is valid for 120 days, or for the duration of your current building permit for this property. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Please note any special requirements that may have been added to the design by this department. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County Environmental Health must also view the installation prior to back filling. Please call well in advance for your final inspection. Your TCO will not be issued until our office receives this certification from the engineer, and views the installation. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. Please notify this office if you have not been contracted to perform this installation. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files High Country Engineering, Roger Neal OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 July 12, 2002 Eagle County Environmental Health Department Attn: Ray Merry P. O. Box 179 Eagle, CO 81631 Re: Lot 6, Sopris Mesa Subdivision, Eagle County, Colorado HCE File Number 2021025.59 Dear Ray: On July 3 and July 12, 2002, High Country Engineering personnel observed the construction of the ISDS for the Montgomery Residence located at on Lot 6, Sopris Mesa Subdivision in Eagle County, Colorado. One 1500-gallon septic tank with baffle and 72 standard Infiltrator units had been installed in a bed configuration. No backfilling had taken place. The contractor was advised to add two (2) additional inspection wells near the front of the bed and to minimize backfill to a depth of 3-feet or less. Otherwise, the installation of the system was in conformance with the intent of the design and I have enclosed pictures of the system and an as -built drawing for your convenience. If you have any questions, or need additional information, please contact us. Sincerely, HIGH COUNTRY EN Roger D. Neal, P Project Manager RDN/djw �'°.A+.�. 12'" fNa� 3" em,aossza ' 1�te ••' 1517 Blake Avenue, Suite 101 14Inverness Drive East Suite D-136 Glenwood Springs; CO 81601 Englewood, CO 80112 Telephone (970) 945-8676 - Fax (970) 945-2555 Telephone (303) 925-0544 - Fax (303) 925-0547 �-_rum c1s P D Box I Aspen,-�C* ig-I_ phone 970m 777 Fie 970,9-2---A3 Date: /-7-A T l 1. s l 1 GGM—�Q—;JMMQ M KI MQ - 71 ❑M i r, • r rni IKIT r �Kll i W�nl TW Gc -W� - 4 F3: 6i V r_-S B li ii nZIN f,...sn miui..... �:....i.., �r.�:,1iar s s � f iC. 1TP5• V1:7 P l7C. SlFS-U�=F`_7 3 :s= ISi-s', i� irs`_,Ei Vs f:i.2Td4r ��4s�;uJ g. �-_- -••• _ Y r-t i1 V MAIM : t 1 Lt LIJV r 'MioltL43mery(CRi";r.+,�i3P i'IIC w?til�lOSe ()r yit15 IllCril0 iS K PrOVIti4 ULIUt�: MI ttt C)riiatiC'.t'a `!il yaw`„' MJ:;tcis7nsrT rJ t" i� , . _ r CAx t� L. 7 1~ sn]f t'rl Tll�l_ i��11t1Tafl , UR ATIM J, VV ddd4al !.� +uvL4t.+u t.0 uv 3 ...: c.f., a-. r.s�a:. �'u%—••--- .--_ __. v � . ')fltl'7 T-T;n -e Cir nntry PnColtler-ring- Inc. (HCE) completed a design for an1riI11Lrrrl05VTPyivit l�nrl ;tcm ba4zi'1 n_il tllrec (S� �Crefi�lw[i ICSi� 4t7Cudici uyrs ''- r•r,a. rt.,l: !-_ + � ,n�i, il,c•, i iPi: V-n , F)T,,, L 32, HP voi7iltT cd an additional percolation test w4b n the Proposed absorption Abed urea. This a dditimial test daia, was then used by i ICE to redosign thu ?±iM `T`hr efmd .. nien;e 3i`eept the �`1 ne I i, 2002 design as IICE final design for construction of the MontgonlcrY ESUS. If you have any quests-ons, Please fce-1 free to contract trio at (970) 945-8676. {,� � r UIetIVti d i11:iiVWa;7tii.1 S�f7'l91 ,., (Y) 81601 14 hivemcss Drivc hurt tiuita tM36 Cotlevmod, CO 80112 'Yflt±vtilv,: ! ,01N 2-S-Ds44 - Fax 061) 925-0547 Till -P-rinviP TI IF my•??C�Mi TI't- Pnf-.I F r d lKITV FNl1 1417al T14 uGr_�C• i April 11, 2002 Gentlemen, Although this design comes from a registered engineer, I feel that the system may be over - designed based upon what some of my immediate neighbors have encountered on their soil profiles and perc. rates. Please let me know if you feel that the system may be downsized, if at all. Your consideration is appreciated. Thank you, Glenn Montgomery 3 v v -C;LwjL 30 5 � lw. — l .3 y q?0 lb 15 3 low 5�0 o.�� 40 qq Hepworth-Pawlak Geotechnical Inc. 5020 County Road 154 mwh Glenwood Springs, Colorado 81601 Phone: 970-945-7988 Fax:970-945-8454 hpgeo@hp-,eotech.com April 11, 2002 Glenn Montgomery 436 Paseo Drive Carbondale, Colorado 81623 Job No. 102 210 Subject: Subsoil Study for Foundation Design and Percolation Test, Proposed Residence, Lot 6, Sopris Mesa, 1021 Green Meadow Drive, Eagle County, Colorado Dear Glenn: As requested, Hepworth-Pawlak Geotechnical, Inc. performed a subsoil study and percolation test for foundation and septic disposal designs at the subject site. The study was conducted in accordance with our agreement for geotechnical engineering services to you dated March 22, 2002. The data obtained and our recommendations based on the proposed construction and subsurface conditions encountered are presented in this report. We previously performed a preliminary geotechnical study for the Sopris Mesa Subdivision submitting our findings in a report dated October 23, 1997, Job No. 197 495. Proposed Construction: The proposed residence will be a two story, wood -frame structure over a basement level located on the lot as shown on Fig. 1. Ground floors will be slab -on -grade. Cut depths are expected to range between about 4 to 8 feet. Foundation loadings for this type of construction are assumed to be relatively light and typical of the proposed type of construction. The septic disposal system is proposed to be located northeast of the residence. If building conditions or foundation loadings are significantly different from those described above, we should be notified to re-evaluate the recommendations presented in this report. Site Conditions: The lot is vacant and located on the uphill side of Green Meadow Drive. The ground surface appears mostly natural and has a strong slope down to the west-southwest at grades from about 5 to 12%. Elevation difference across the proposed residence is about 4 feet. The lot is vegetated with grass and scattered weeds and brush. Subsurface Conditions: The subsurface conditions at the site were evaluated by excavating two exploratory pits in the building area and one profile pit in the septic disposal area at the approximate locations shown on Fig. 1. The logs of the pits are presented on Fig. 2. The subsoils encountered, below about 2 to 21/2 feet of topsoil, consist of stiff to very stiff sandy clay. The clay subsoils extended to the depths of 8 Glenn Montgomery April 11, 2002 Page 2 and 61/2 feet at Pit 2 and the Profile Pit, respectively, and to a depth of 6 feet at Pit 1 where stiff sandy silt and clay were encountered to the depth of 91/2 feet. Results of swell -consolidation testing performed on relatively undisturbed samples of the subsoils, presented on Fig. 3, indicate low compressibility under existing moisture conditions and light loading. The clay sample (Pit 2 at 5 feet) showed a moderate expansion potential when wetted under a constant light surcharge. The laboratory testing is summarized in Table I. No free water was observed in the pits at the time of excavation and the soils were slightly moist to moist. Foundation Recommendations: Considering the subsoil conditions encountered in the exploratory pits and the nature of the proposed construction, we recommend spread footings placed on the undisturbed natural soil designed for an allowable bearing pressure of 2,500 psf for support of the proposed residence. Due to the swell potential of the subsoils the footings should also be designed for a minimum dead load pressure of 800 psf. There could be some post -construction foundation movement if the bearing soils become wetted. Precautions should be taken to prevent wetting of the bearing soils. Footings should be a minimum width of 16 inches for continuous walls and 2 feet for columns. All topsoil and loose or disturbed soils encountered at the foundation bearing level within the excavation should be removed and the footing bearing level extended down to the undisturbed natural soils. Exterior footings should be provided with adequate cover above their bearing elevations for frost protection. Placement of footings at least 42 inches below the exterior grade is typically used in this area. Continuous foundation walls should be well reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 12 feet. Foundation walls acting as retaining structures should be designed to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 55 pcf for the on -site soil as backfill. The backfill should not contain vegetation or topsoil. Floor Slabs: The natural on -site soils, exclusive of topsoil, are suitable to support lightly loaded slab -on -grade construction. There could be some slab heave if the expansive clay subgrade becomes wetted. Providing structurally supported floors over crawlspace would provide a low risk of ground floor movement. To reduce the effects of some differential movement, nonstructural floor slabs should be separated from all bearing walls and columns with expansion joints which allow unrestrained vertical movement. Interior non -bearing partitions resting on floor slabs should be provided with a slip joint.at the bottom of the wall so that, if the slab moves, the movement cannot be transmitted to the upper structure. Slip joints which will allow H-P GEOTECH Glenn Montgomery April 11, 2002 Page 3 at least 11/a inches of vertical movement are recommended. Floor slab control joints should be used to reduce damage due to shrinkage cracking. The requirements for joint spacing and slab reinforcement should be established by the designer based on experience and the intended slab use. A minimum 4 inch layer of free -draining gravel should be placed beneath basement level slabs to facilitate drainage. This material should consist of minus 2 inch aggregate with less than 50 % passing the No. 4 sieve and less than 2 % passing the No. 200 sieve. All fill materials for support of floor slabs should be compacted to at least 95 % of maximum standard Proctor density at a moisture content near optimum. Required fill can consist of the on -site soils, or suitable imported granular soils, devoid of vegetation, topsoil and oversized rock. Underdrain System: Although free water was not encountered during our exploration, it has been our experience in the area, and where clay soils are present, that local perched groundwater can develop during times of heavy precipitation or seasonal runoff. Frozen ground during spring runoff can also create a perched condition. We recommend below -grade construction, such as retaining walls and basement areas, be protected from wetting and hydrostatic pressure buildup by an underdrain system. The drains should consist of drainpipe placed in the bottom of the wall backfill surrounded above the invert level with free -draining granular material. The drain should be placed at each level of excavation and at least 1 foot below lowest adjacent finish grade and sloped at a minimum 1 % to a suitable gravity outlet. Free -draining granular material used in the underdrain system should contain less than 2 % passing the No. 200 sieve, less than 50 % passing the No. 4 sieve and have a maximum size of 2 inches. The drain gravel backfill should be at least 11/a feet deep. Surface Drainage: Positive exterior surface drainage is an important aspect of the project to prevent wetting of the soils below the building. The following drainage precautions should be observed during construction and maintained at all times after the residence has been completed: 1) Inundation of the foundation excavations and underslab areas should be avoided during construction. Drying could increase the expansion potential of the soils. 2) Exterior backfill should be adjusted to near optimum moisture and compacted to at least 95 % of the maximum standard Proctor density in pavement and slab areas and to at least 90 % of the maximum standard Proctor density in landscape areas. Free -draining wall backfill should be capped with about 2 feet of the on -site, finer graded soils to reduce surface water infiltration. H-P GEOTECH Glenn Montgomery April 11, 2002 Page 4 3) The ground surface surrounding the exterior of the building should be sloped to drain away from the foundation in all directions. We recommend a minimum slope of 12 inches in the first 10 feet in unpaved areas and a minimum slope of 3 inches in the first 10 feet in pavement and walkway areas. 4) Roof downspouts and drains should discharge well beyond the limits of all backfill. 5) Landscaping which requires regular heavy irrigation, such as sod, should be located at least 5 feet from the building. Percolation Testing: Percolation tests were conducted on March 29, 2002 to evaluate the feasibility of an infiltration septic disposal system at the site. One profile pit and three percolation holes were dug at the locations shown on Fig. 1. The test holes (nominal 12 inch diameter by 12 inch deep) were hand dug at the bottom of shallow backhoe pits and were soaked with water one day prior to testing. The soils exposed in the percolation holes are similar to those exposed in the Profile Pit shown on Fig. 2 and consist of stiff to very stiff, sandy clay. The percolation test results are presented in Table H and indicate average percolation rates of about 26 and 28 minutes per inch at locations P-1 and P-3. At P-2 the average percolation rate was about 180 minutes per inch. Based on the subsurface conditions encountered and the percolation test results, the tested area may be suitable for a conventional infiltration septic disposal system. A civil engineer should design the septic disposal system. Limitations: This study has been conducted in accordance with generally accepted geotechnical engineering principles and practices in this area at this time. We make no warranty either expressed or implied. The conclusions and recommendations submitted in this report are based upon the data obtained from the exploratory pits excavated at the locations indicated on Fig. 1, the proposed type of construction and our experience in the area. Our findings include interpolation and extrapolation of the subsurface conditions identified at the exploratory pits and variations in the subsurface conditions may not become evident until excavation is performed. If conditions encountered during construction appear different from those described in this report, we should be notified at once so re-evaluation of the recommendations may be made. This report has been prepared for the exclusive use by our client for design purposes. We are not responsible for technical interpretations by others of our information. As the project evolves, we should provide continued consultation and field services during construction to review and monitor the implementation of our recommendations, and to verify that the recommendations have been appropriately interpreted. Significant design changes may require additional analysis or modifications to the recommendations presented herein. We recommend on -site observation of excavations and foundation H-P GEOTECH Glenn Montgomery April 11, 2002 Page S bearing strata and testing of structural fill by a representative of the geotechnical engineer. If you have any questions or if we may be of further assistance, please let us know. Sincerely, CAL, INC. David A. Young, P Reviewed by: Daniel E. Hardin, P.E. DAY/ksw attachments H-P GEOTECH LEGEND: ■ EXPLORATORY PIT 0 PERCOLATION TEST HOLE 104 BUILDING / ENVELOPE / 102 \ � 100 1 P2/ Op3 /. / ■ PROFILE / / PIT / P 1 106 PIT 2 PROPOSED ■ PIT 1 `RESIDENCE \ 108 � � \ LOT 6 / BOUNDARY APPROXIMATE SCALE 1"=40' 98 w 0 0 z w w w 102 210 HEPWORTH-PAWLAK LOCATION OF EXPLORATORY PITS GEOTECHNICAL, INC. AND PERCOLATION TEST HOLES Fig. 1 1 10 LEGEND: NOTES: PIT 1 ELEV.= 104' we=14.9 DD=100 -200=86 WC=15.4 D0=100 PIT 2 ELEV.= 100' WC=119 DD=106 TOPSOIL; organic silty clay, medium stiff, moist, dark brown. PROFILE PIT ELEV.= 100' CLAY (CL); sandy, stiff, slightly moist to moist, brown, medium to high plasticity. SILT AND CLAY (ML—CL); sandy, stiff, moist, light brown, low plasticity, calcareous. 2" Diameter hand driven liner sample. 1. Exploratory pits were excavated on March 28, 2002 with a backhoe. 2. Locations of exploratory pits were measured approximately by pacing from features shown on the site plan provided. 3. Elevations of the exploratory pits were obtained by interpolation between contours on the site plan provided. Pit logs are drawn to depth. 4. The exploratory pit locations and elevations should be considered accurate only to the.degree implied by the method used. 5. The lines between materials shown on the exploratory pit logs represent the approximate boundaries between material types and transitions may be gradual. 6. No free water was encountered in the pits at the time of excavating. Fluctuations in water level may occur with time. 7. Laboratory Testing Results: WC = Water Content ( % ) DD = Dry Density ( pcf ) —200 = Percent passing No. 200 sieve IGEO 102 210 TEOCHNICALWINC. I LOGS OF EXPLORATORY PITS Fig. 2 Moisture Content 15.4 percent Dry Density = 100 pcf Sample of.- Sandy Silt and Clay From: Pit 1 at 9 Feet own E 1 0" 0 1 N No movement aupon E11111111mal"b— E 2 wetting 0 U 3 0.1 1.0 10 100 APPLIED PRESSURE — ksf Moisture Content = 13.9 percent Dry Density 106 pcf Sample of. Sandy Clay From: Pit 2 at 5 Feet o_ U c 1 a x x t,.► I 0 C 0 a E 0 U 2 0.1 1.0 10 100 APPLIED PRESSURE — ksf 102 210 HEPWORTH—PAWLAK SWELL CONSOLIDATION TEST RESULTS Fig. 3 GEOTECHNICAL, INC. i �� °1ui■ �iim n' IIII■; EM11 111 Jill, �1��11 11111 III 1111 N N O O z U z Cn J a W z � 2 U) uj O L" CLU 0 V u O Y m � a F- J Q J IL Q i.V Q O IL /u)/� VJ W 2 co a cc U O � U h C6 m CO co U U U C Cca C < Cn fry ui 7 _ W H It W Z LL O a a H z o M U U X a ° Z a C7 LLI cc W ° � o J � f O Z N LU W > L) N CD w o W a a z Q z y O H a ° a (J J W a o J ac ~ — } H p n p O O z r- z LO CY) S z O «m a � LO U O J J a N HEPWORTH-PAWLAK GEOTECHNICAL, INC. TABLE II PERCOLATION TEST RESULTS JOB NO. 102 21.0 HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MIN./INCH) P-1 45 15 water added 61/8 5 1 /8 1 26 5 1/8 4 114 7/8 4 1/4 3 3/4 1/2 3 3/4 2 3/4 1 4 3/8 3 5/8 314 3 5/8 3 1/8 1/2 3 1/8 2 5/8 1/2 P-2 50 15 6 1 /2 6 3/8 1/8 180 6 3/8 6 1/4 1/8 6 1/4 6 114 0 6 1/4 6 1/4 0 6 1/4 61/8 1/8 61/8 61/8 0 6 118 6 1/8 P-3 46 15 9 5/8 8 1 /2 1 1/8 28 11 8 1/2 7 1/8 1 3/8 7 1/8 6 112 518 6 1/2 5 1/2 1 5 112 4 718 5/8 4 7/8 4 318 112 4 3/8 3 7/8 1 1/2 1 Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaked on March 28, 2002. Percolation tests were conducted on March 29, 2002. The average percolation rate were based on the last three readings of each test. KPWORTH - PAWLAK GEOTECHNICAL, INC. 502County Road 154 Glenwood Springs, Colorado $1e01 0rt Phone: 970-a45-7988 Fax: 970-945-8454 ®-mail: hpgeo@hpgeotech.com FAX TRANSMITTAL FORM DATE: PROJECT NO.Z/ 0 TO: 6Le vt vt go n tG o vine-t FAX NO: 9Z,5 Z6-q s FROM: NUMBER OF PAGES: MESSAGE: - e- i1e�4 f v e- lOd ` r t o e- ct r eG i�a a CA vKG Grto (.j r n G�ISC. cam �_S' The original of this transmittal will be sent by: Ordinary Mail 'a Overnight 1U Fax Only Other 'W3 The information contained in this facsimile message is confidential and intended for the sole use of the individual named above. If you are not the intended recipient, received this communication in error, or if problems occur with transmission, please notify us at 970-945-7988. Sent By: 20iti0'd' H331039 d—H 92:VT MOO—SO—Nnf HEPWORTH - PAWLAK CEOT ECHNI�C' �� �� ``�Y (�,� ._....._ .. ................__._ CAL INC.tiVC. OG OF BORING V" 3'ro �'" JOB NAME'. t10 i �1121; W2�6­ DATE- /7 G Z—. OB NO.wo „_— BORING LOCATIONS -c�,�� --�-�--. --�. ENGINEER ORING ELEVATION DRILLING METHOD C'!{?i �'( �r _.__. RIG )EPTH (ft.) UNIFIED SOIL DESCRIPTION ROM TO SYMBOL DRILLING CONDITIONS r ; f7i REFUSAL DIPTHS: " PLASTIC Q a ° GRADING �, ° MOIST�. COMMENTS .° CEMENTED BLOW SAMPLEOIL H TYPE SYMBOL $A w DEr111SiTY �. BLOCKY, Q Q �, QUALITY OF SAMPLE COUNT yv� ��� no SA�IfIp�E TYPE LEGENL7 WATER LEVEL -PVC DIA/TYPE :AL = CALIFORNIA LD = LARGE DISTURBED CAVE DEPTH ' $LOTTED LENGTH ;S = SPLIT SPOON SD = SMALL DISTURBED iT = SHELBY TUBE HD HAND DRIVEDATE I ME PVC DEPTH £0/EO'd H331030 d-H L£:VT z00z-SO-Nnf £0'd -ld101 JOB No, Qi DATE 4 t - a Z FIELD TECH. 4 HOLE HOLE TIME DEPTH TO DEPTH TO DEPTH OF DROP IN PERCOLATION NO. DEPTH INTERVAL WATER AT WATER AT WATER 1N WATER RATE (IN.) (MIN.) START (1N,) FINISH (IN.) HOLE (IN.) LEVEL (IN.) (MIN./IN.) 1ti 0 ` pw II " i�S'< ow e w 0.�5CfGQl0.tGi bc.st�laM Ic.S� tf{�'��' i���l tl a p it c r � t5 fl 1. Y IA , 3 S" rLl U• 45 �e .r NOTES: nor a (GarvK5 arc �� -z% £0/£0'd H03103g d-H L£:VT Z00Z-90-Nnf ISDS Permit # ` 8 3 -O.� Date 0, IMS Final Inspection Completeness Form �✓ Tank is gal. Tank Material /- -�- Tank is located ! y ft . and _degrees fro � �-�` � � - r ` 61e�l 1pss..n.ae l.oans�c► I Tank is located ft. and degrees from (ram i.oa.ot) ►� Tank set level. Tank lids within 8~ of finished grade. Size of field ft2 units lineal ft. /Technology Cleanout is installed in between tank and house(+ 1/100ft). There is a "T" that goes down 14 inches in the inlet and outlet of the tank: Inlet.and outlet is sealed with tar, -,tape,..rubber gasket etc. 0 Tain)c ;h-as two dompartments with the l:aieg r- :ept partmeat closest to house. / I�+saeure: d.Stance and relative direp� crt�:to:,-1 elci: � �,�IC/C Depth of field. ft. "Soil interface raked. Inspection portals at the.end of each trench_. Proper distance to setbacks. Chambers properly installed as per manufacturers specifications. (Chambers latched, end plates properly installed, rocks 'removed from trenches, etc.) Type of pipe used for building sewer line leach field Other Inspection meets requirements. Copy form to installer's file if recommendations for improvement were suggested. ACTION TAKEN: Setbacks Well -Potable House Property Lake Dry Tank Drain Water Lines line Stream Gulch Field 100 25 20 10 50 25 10 10 50 10 5 10 50 10 * 10 _. _._ EAGLE- CE)UNTY--E-W; HEALTH P.O. BOX 179 EAGLE, CO 81631 PROOMI MI (Singh Sheen) 2h&I (Padded) C ®hK., Groh,, Mm 01471. To Order PHONE TOLL FREE I-OW225-00 JOB SHEET NO. I OF, CALCULATED BY, DATE ;�a L'�.�,d'��r •�� y ; � � s,- � � � � } � �� s ., " r re + ��� � � z .: a � s�• _ _ _ _ � ��s 4ti) � _w - � ^.�� :�.� a � 1 .. : ti _. � .. sf Y ' _ ^,� �� �1 _ ` :i G.f _ _ y� „r � � , � � +� r . .•- � 7 � Y � ~ .' t . *"� �' � 4 � i M r .� s .! � ' r'of• �',` f s�� +t .?1 yes a ,y f . � � .U't_� �.+ .�, i � + S; • � -;,ur� + �t•.yy'� � .ifs _,5 a. . • r`• �• r✓ �. r 2183-01 Tax #2391-214-02-005 JOB NAME_ Lot #6, Sopris Mesa MONTGOMERY 1419* Green Meadow Drive l(7� JOB NO. P _ LA JOB LOCATION BILL TO DATE STARTED DATE COMPLETED DATE BILLED LIF Ps.' -/ ' dry l �//^� G✓',�7 �f� t1� r J i L � 2 p _ n i+�vi-- �J���z VA JOB COST SUMMARY TOTAL SELLING PRICE TOTAL MATERIAL TOTAL LABOR - lo -ZI L/ Al ()-)I INSURANCE L� L v ;, SALES TAX Us r mot/! �! MISC. COSTS 0, 114iij aljj�t�-j TOTAL JOB COST GROSS PROFIT rrll !� V T LESS OVERHEAD COSTS % OF SELLING PRICE NET PROFIT aos Fo1DBa Product rra„ �, .� �J '� j� �. JOB FOLDER Y-�������7 �—d��� Printed In USII C�V� 6 - 10( a4wj 4L -roe i ocv-✓' r` e 1iaz� J O� ""7t a 6v->_ _ `�1 a�o c� -- lf;-'l /'t-eat I .1 ' � .� C.� �, � t ra- ! `�'`�' �GV ✓r-e.,r- r- r ! �-SfG�, � � � Gt, �- o v�7' �, ti is h.t� �e t--c.o � �; . IVI-k 'o" �r� �Lc<c 1Gx ai o t st-e c-- Recycled Content 10% Post -Consumer 1 • IVII 11 1 1 lvlr%1 SCALE: 1 "= 2000' NOTE 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE EAGLE COUNTY REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS.. 2. FLOW FOR BED: 4 BEDROOMS * 2 PERSONS/BEDROOM * 75 GALLONS/PERSON/DAY IS: 600 GPD = AVERAGE DAILY FLOW. DESIGN FLOW = 1.5 * AVERAGE = 900 GPD (0) ***REMOVE ANY GARBAGE GRINDERS FROM RESIDENCE*** SEPTIC TANK: MINIMUM TOTAL TANK SIZE: Q * I DAY/24 HRS * 30 HRS = 1125 GPD INSTALL ONE 1250-GALLON TANK WITH BAFFLE ***INSTALL EFFLUENT FILTER IN SEPTIC TANK OUTLET*** STANDARD ABSORPTION AREA: A = DESIGN FLOW APPLICATION RATE OF 0.65 GAL/SF/DAY APPLICATION RATE BASED ON PERCOLATION RATES FOR PITS 900 GPD 1385 SF #1. #3 - and #4 (CDOH). - = .65 GPD/SF - _ USE OF STANDARD INFILTRATOR UNITS IN A BED CONFIGU INCREASE AREA BY 1.30 PER REGS A REDUCE AREA USE OF INFILTRATOR UNITS (1385*1.30*0. /15.5 SF/UNIT), UNITS REQUIRED. 70 3. CLEAN OUTS ARE REQUIRED AT ALL jBENDS AND AT LEAST EVERY 100 FEET ALONG THE HOUSE SEWER. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS, PRIOR TO THE ABSORPTION AREA, TO PREVENT INFILTRATION. 5.TOPSOIL COVER MAY BE VARIED (WITH 1 FOOT MINIMUM) TO ALLOW LANDSCAPING. 6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN ONE-HALF FOOT OF FINAL GRADE. 7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. 8. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM ABSORPTION FIELD AREA USING DRAINAGE SWALES AS NECESSARY. 9. SOILS AND PERCOLATION INFORMATION PROVIDED BY H.P. GEOTECH, JOB NO. 102 210 DATED APRIL 1 AND 18, 2002. AVERAGE PERC. RATE = 23 MPI. 10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. `PERMIT MUST BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL' AND PROVIDE REPORT TO COUNTY. 11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 12.- SITE PLAN INFORMATION FROM SITE OBSERVATION. NO SURVEY WAS PERFORMED. 13. INSTALL BLUEBOARD INSULATION OVER SEWER PIPE WHEREVER DEPTH IS LESS THAN 5.0 FEET. 14. THE ENGINEER SHALL BE CONTACTED FOR SITE INSPECTION PRIOR TO BACKFILLING OF SYSTEM COMPONENTS. 15. DESIGN OF ABSORPTION TRENCHES BASED ON SOIL PROFILE INDICATING 1-FOOT TOPSOIL OVERLYING MEDIUM STIFF SILTY CLAY PROFILE DEPTH OF 8-FEET. GENERAL ABSOREMON TW�__ NOTES 1. ABSORPTION LATERALS SHALL NOT EXCEED -100 FEET IN LENGTH 2. THE BOTTOM OF EACH ABSORPTION TRENCH SHALL BE LEVEL. 3. DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND TRENCHES, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 4. TRENCH LATERALS SHALL FOLLOW CONTOURS. 5. INSTALL INFILTRATOR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, 6. TRENCH BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE SOIL SMEARS INCURRED DURING EXCAVATION. 7. NO EXCAVATION OF ABSORPTION FIELD IS TO BE DONE DURING WET -WEATHER AND USE OF RUBBER TIRE VEHICLES OVER ABSORPTION AREA IS PROHIBITED 8. BOULDERS EXISTING WITHIN THE TRENCH SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF ONSITE SELECT, OR PIT -RUN MATERIAL. 9. IN ALL TRENCH CONFIGURATIONS, SERIAL DISTRIBUTION SHALL BE INSTEAD OF EQUILATERAL DISTRIBUTION TO INCREASE SETTLING�a,��T TIME AND PROTECT THE BACTERIAL B I 0-MAT . _ 4,.D. �F 10. BEND IN TRENCH SHALL BE MADE WITH END PLATES V j AND 4"o PVC OR MANUFACTURER'S PREFABRICATED BENDS. f{ _ w U w d .J Q Z O Z O _ �5 O > 0 LJ Q O O w w N N J w w N w N O w Q cD O Z (14 Z O tf N (n Fw- w w of Y Q J cC z� V 00 00 Z w� c W qe ❑V Z Vir z 0) 0 �::0^ z w -Z= r�lJ�LL s0ro H c "-- z �n O ZFE U a��� �� _ W �00 V rnrn T i m w Z S o U) Q O �- < of 0 CO m O 0(-) U) � W 0(13 0~ Z 00 OU Z F- �r. Ft ;J a O coo J w = �0 0O > _I 0 Z PROJECT NO. 2021025.59 SHEET 1