HomeMy WebLinkAbout700 W Diamond Star Rd - 193926303005INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway • Eagle, CO 81631
Telephone: (970) 328-8755
COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 2060-00 BP NO. 1 3 4 6 3
OWNER: THOMAS ROULSTON PHONE: 440-350-1230
MAILING ADDRESS: 4000 CHESTER AVE. CLEVELAND, OH 44103
APPLICANT: MARK SCULLY PHONE: 970-376-1807
SYSTEM LOCATION: 700 WEST DIAMOND STAR RANCH RD., EAGLE, CO TAX PARCEL NO. 1939-263-03-005
LICENSED INSTALLER: STENSON EXCAVATING, BILL STENSON LICENSE NO.28-00 PHONE: 970-926-3849
DESIGN ENGINEER: LKP ENGINEERING, LUIZA PETROVSKA PHONE NO. 970-926-9088
INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 3 BEDROOM RESIDENCE
1000 GALLON 3 COMPARTMENT CONCRETE SEPTIC TANK WITH AN ELECTRIC LIFT STATION THAT DELIVERS 163 GALLONS PER DOSE, AND 1125
SQUARE FEET OF ABSORPTION AREA CREDIT, VIA 36 INFILTRATOR UNITS, AS PER ENGINEER'S DESIGN DATED NOVEMBER 15, 2000.
SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN WITH TRENCHES NO DEEPER THAN 3 FEET TO MAINTAIN A 4 FEET SEPARATION
TO BEDROCK. THE WELL MUST BE AT LEAST 100 FEET FROM THE LEACH FIELD AND 50 FEET FROM THE SEPTIC TANK. THE ENGINEER IS RESPON-
SIBLE FOR THE FINAL INSPECTION. DO NOT BACK FILL ANY PART OF THE INSTALLATION UNTIL THE ENGINEER HAS INSPECTED AND APP-
ROVED THE SYSTEM. AN AS -BUILT DRAWING OF THE INSTALLATION THAT INDICATES THE LOCATION OF THE WELL IS ALSO NEEDED.
THE BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SYSTEM HAS BEEN INSPECTED AND APPROVED.
/f
ENVIRONMENTAL HEALTH APPROVAL: DATE: / 1 o. Z-O/ z000
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS,
ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING
REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL
AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO
BE LICENSED.
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM
IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: 14 8 8 SQUARE FEET (VIA 48 INFILTRATOR UNITS )
INSTALLED CONCRETE. SRPTTCrANK: _j_Q_Q_0GALLONS IS LOCATED DEGREES AND 17 FEET 4 INCHES
FROM THE CLEANOUT ON THE EAST SIDEOF`THE HOUSE.
COMMENTS: THE ENGINEER'S FINAL CERTIFICATION AND AS—RTTTT,T DRAWING RRCRI-VED—ON
ON NOVEMBER 6, 2001. THIS SYSTEM IS LARGE ENOUGH FOR A 3 BEDROOM RESIDENCE.
ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS
COMPLETED. _--,�
ENVIRONMENTAL HEALTH APPROVAL�.i//I ,Q DATE: NOVEMBER 8, 2 0 01
Incomplete Applications Will NOT Be Accepted
.(Site Plan MUST be attached)
I SDS Permit # `�
Building Permit #
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY
P. 0. BOX 179
EAGLE, CO 81631
328-.1875.5./.92.77a823. (.Ei:,Uebel)
* FEE. _SCHEDULE
* PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 *
* SIZING AND SITE VISIT FEE $85.00 (WHEN ENVIRONMENTAL HEALTH SIZES THE *
* SYSTEM -USING YOUR SOILS REPORT)
* MAKE ALL REMITTANCE PAYABLE TO: -"EAGLE COUNTY TREASURER"
PROPERTY OWNER: j j6d lq a S ACA','],F7709
MAILING ADDRESS: Z1660 0We _06L. auk 0 ' PHONE: - 30 -1-36
APPLICANT/ CONTACT-- PERSON: ECG //f ' PHONE: 76 107
LICENSED SYSTEMS CONTRACTOR: _5j-el;S6cI L✓X('�[lce �f��J _^/'It HONE: 41710361
COMPANY/DBA: ADDRESS:
PERMIT APPLICATION IS FOR: `r.,/ NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
r
Legal Description:
Tax Parcel Number:
Physical Address
e
. 24 q o �&
'dt% Lot Size:
BUILDING TYPE: (Check applicable category)
(l'�) Residential/Single Family Number of Bedrooms_
( ) Residential/Multi-Family* Number of Bedrooms
( ) Commercial/Industrial* Type
*These systems require design by a Registered Professional Engineer
TYPE OF WATER SUPPLY: (Check applicable category)
Well ( ) Spring ( ) Surface
( ) Public Name of Supplier:
EAPPLICANT SIGNATURGlr' Date:
AMOUNT PAID: 6b RECEIPT DATE:
CHECK # : _ ( �lo CASHIER:
Community Development Department
(970)328-8730
FAX (970) 328-7185
TDD (970) 328-8797
Email: eccmdeva@vail.net
http: //www.eagle-county.com
EAGLE COUNTY, COLORADO
Date: November 20, 2000
TO: Stenson Excavation
FROM: Environmental Health Division
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
RE: Issuance of Individual Sewage Disposal System Permit No.2060-00. Property
Location: 700 West Diamond Star Ranch Rd., Eagle, CO., Roulston residence.
Enclosed is your ISDS Permit No. 2060-00. It is valid for 120 days. The enclosed copy of the
permit must be posted at the installation site. Any changes in plans or specifications
invalidates the permit unless otherwise approved. Please note any special requirements
that may have been added to the design by this department.
Systems designed by a Registered Professional Engineer must be certified by the Engineer
indicating that the system was installed as specified. Eagle County does not perform final
inspections on engineer designed systems. Your TCO will not be issued until our office
receives this certification.
Permit specifications are minimum requirements only, and should be brought to the property
owner's attention.
This permit does not indicate conformance with other Eagle County requirements. Please
notify this office if you have not been contracted to perform this installation.
If you have any questions, please feel free to contact the Environmental Health Division at 328-
8755.
cc: files
LKP Engineering, Luiza Petrovska
DEPARTMENT OF
ENVIRONMENTAL HEALTH
(970) 328-8755
FAX (970) 328-8788
TDD: (970) 328-8797
TOLL FREE: 800-225-8136
www.eagle-county.com
EAGLE COUNTY, COLORADO
November 8, 2001
Thomas Rouston
4000 Chester Ave.
Cleveland, OH 44103
Raymond P. Merry, REHS
Director
RE: Final of ISDS Permit #2060-00 Tax Parcel #1939-263-03-005. Property
location: 700 West Diamond Star Ranch Rd., Eagle, CO.
Dear Mr roulston:
This letter is to inform you that the above referenced ISDS Permit has been inspected and
finalized. Enclosed is a copy to retain for your records. This permit does not indicate
compliance with any other Eagle County requirements. Also enclosed is a brochure regarding
the care of your septic system.
Be aware that later changes to your building may require appropriate alterations of your septic
system.
If you have any questions regarding this permit, please contact the Eagle County Environmental
Health Division at (970) 328-8755.
Sincerely,,
Janet Kohl
Eagle County Environmental Health Department
ENCL: Informational Brochure
Final ISDS Permit
cc: files
OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179
LKP
Engineermi
s';1 CIVIUMOTECEMCAL
July 9, 2001
Mr. Mark Scully
Scully Building Corporation
F,G. Box 2300
Edwards, CO 81632
Attention: Mark Scully,
R-E: Inspection of Septic Sy4tern Instanqtion
Parcel 5, Diamond Stag Ranch
700 West Diamond Star Ranch Road
Eagle County, Colorado
.Project No. 0115 - permit No. 2060-00
At your request and at the request of Bill Stenson, an March 19 and 20, 2001, we visited
the construction site on Parcel 5, Diamond Star Ranch, 700 West Diamond Star ranch Road,
Eagle County, Colorado. The pwpose of our site visits was to observe the installation of the
septic system.
They installed the system in overall compliance with the septic system design, Drawing
No. 20198SD.DWG, dated November 15, 2000. They installed a 1000-gallon, three
compartmeuts, a precast, concrete septic tank. In the last compartment of the septic tank, was a
Zoeller pump, Model 264. The tank had three access openings, one over each of the
compartments. The effluent line from the pump tank to the first infiltrator of the leaohfield wass.a
total distance of 166 feet, The effluent line was 24nch diameter sch40 pvc. The pump was sized
to have 169 gallons per dose. The dosing, the floats function and the alarms were tested by Bill
Stenson. The alarm was to be installed in the downstairs hallway.
Forty-eight, Standard Infiltrator Chambers were installed in three trenches. Each roar of
trenches contained sixteen infiltrators. The infiltrators were connected with serial distribution. Ira
the first and last infiltrator of each trench, inspection parts were installed. In addition, in the first
row of trenches, 2 sticks of perforated, sch200 pvc, were suspended from the top of the
infiltrators. Horizontal distance from center to center of the trenches, was 9 feet or more. All
piping 'wa.s sch40, 4-inch PVC. The depth of the trenches was no more than 36 inches.
If you have any l.' t i N please do not hesitate to call.
Sincerely,
LEI" En.gineerin " - 7 ) ` °e _
s
4
Luiza Petrovska, / �
President 'air+.�••rr+:�
""'�Yi�N�l sae
Co. leis. Laura Fawcett, Eagle County Environmental Health Division, fax: 328-0349
Enclosure
�:1�I�FileslccyweidoclW�1'�c'�rc��no�n�x_,,,,n,,, rxmr,
P.Q. Box 2837, Edwards, CO 81632, (970) 926-9088 Tel, (970) 926-9089 Fax
TO 39VJ ONI 9NTN33NT9N3 c4_A3
LKP ENGINEERING, INC.
P.O. Box 2837
Edwards, CO 81632-2837
Fax (970) 926-9089
PERCOLATION TEST RESULTS
Location: Parcel 5, Diamond Star Ranch
East of the Town of Eagle
Eagle County, Colorado
Project No.: 20198
Client: Thomas & Lois Roulston
2627 Fairmont Blvd.
Cleveland Heights, Ohio 44106
P-1
P-2
P-3
TIIv1E/DEPTH
16"
16-8/16"
16-8/16"
3:05
3-12/16"
6"
3-8/16"
19-12/16"
7-12/16"
3:15
16" add
water 10"
12-4/16"
7-4/16"
1-4/16"
13-4/16"
3-8/16"
3:25
11"
8/16"
8-12/16"
1-8/16"
16-8/16" add
water 9-8/16"
3-4/16"
3:35
11-4/16"
4/16"
9-8/16"
12/16"
10"
8/16"
3:45
11-8/16"
4/16"
10-4/16"
12/16"
10-8/16"
8/16"
3:55
11-12/16"
4/16"
11"
12/16"
11"
8/16"
4:05
12"
4/16"
11-12/16"
12/16"
11-8/16"
8/16"
PERC RATE
40 MIN/INCH
13.3 MIN/INCH
20 MIN/INCH
AVG PERC:
25 MINUTES PER INCH
Average Percolation Hole Diameter:
Holes Dug and Presoaked: 10-2-00
Test Run: 10-3-00
10" PROFILE HOLE:
0 to 2' Topsoil
2' to T Light brown sandy gravel
Refusal @ 7'
No Ground Water
Q(/4L/TY PUMPS gINCE �ffgg „
Product information `EacoA,p
presented here reflects
conditions at time of
publication. Consult factory . L,
regarding discrepancies or
inconsistencies.
http://Www.zoeller.com
COMPARE THESE FEATURES
f E6< Y
f Esr:
MAIL TO., P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731. 1 (800) 928-PUMP • FAX (502) 774-3624
• Non -Clogging Vortex Impeller Design.
• Float operated, submersible (NEMA 6) 2 pole switch.
• Durable cast iron construction. Cast iron switch cap,
motor, and pump housing.
• Stainless steel screws, bolts, handle, guard, arm and
seal assembly.
• Engineered, glass filled, plastic impeller with metal
insert.
• UL-listed 3-wire cord and plug.15 ft. cord standard for
automatic & nonautomatic.
• Thermal overload protection.
• Oil filled PSC motor - hermetically sealed.
• Engineered plastic base.
.4 H.P. 115V & 230V, 1 Ph., 60 cycle, 1725 RPM.
• Carbon and ceramic shaft seal.
• Oil Lubricated Bearings.
• Passes 2-inch spherical solids.
• 2" NPT Discharge.
• On point - 12'/z'
• Off point - 4'/z"
SIMPLEX AND DUPLEX
SYSTEMS AVAILABLE
r
http.,Ilwww.zoeller.com
MAIL TO: P.O. BOX 16347
Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road
Louisville, KY 40211-1961
(502) 778-2731. 1(800) 928-PUMP
FAX (502) 774-3624
ZManufacturers of...
0 `rZIWITY PL/MP6 gl%_-E 1g,7
264 SERIES
SECTION: 2.30.015
FM1495
1097
Supersedes
0996
WA S®r;, E r- N f E
(For Pump Prefix Identification see News & Views 0052)
SUBMERSIBLE
SEWAGE/EFFLUEftT-
U L OR U E'VAT E R f INt G l" U i,`i P e•m•�•.�
y CRPFS54.
2" NPT DISCHARGE
CID
MODELS AVAILABLE
• Automatic
• Nonautomatic (for variable level systems)
• BE & BN264 available packaged with
Piggyback variable level float switch.
'May be used in those states where codes do not restrict solids size in effluent systems.
SSPMA
/MEMBER
SUMP
GNn 11.1;E
RS. ASSN.
W HEAD CAPACITY CURVE
2 UJ `` 264 MODELS
6 20— I 1 1 1
2 T 5
0 i
U.S. GALLONS 20 40 60 80 100
LITERS
0 80 160 240 320
FLOW PER MINUTE
009931
TOTAL DYNAMIC HEAD/CAPACITY
PER MINUTE
SEWAGE AND DEWATERING
264 MODELS
Ft.
Meters
Gal.
Ltrs.
5
1.52
90
341
to
3.05
60
227
15
4,57
22.5
6s
Lock Valve: 18 it.
FM 1494
IL— 8 21/64 PAGE 2 OF 2
4 13/16 Fes— 6 13/32 —_i
4 13/16 t
o
6 35/64
643
CONSULT FACTORY FOR SPECIAL APPLICATIONS
Electrical alternators for duplex systems available with High water alarms available.
variable level float switches. Mechanical alternators available for duplex systems.
Minimum recommended basin size A CAUTION Maximum temperature of sewage or
Simplex-18"00" dewatering must be limited to 130' F. (54' C.)
Duplex-30"x30" For over 130° F. (540 C.) special quotation required.
Standard Automatic - Weight 39 Ibs..4 H.P.
264 MODELS
CONTROL SELECTION
Model
Volts Ph
Mode
Amps
Simplex
Duplex
M264
115 1
Auto
9.4
1 or 1 & 7
N264
115 1
Non
9.4
2 or 2& 6
3 or 4& 5
D264
230 1
Auto
4.7
1 or 1 & 7
E264
230 1
Non
4.7
2 or 2& 6
3 or 4& 5
SELECTION GUIDE
1. Integral float operated 2 pole mechanical switch, no external control required.
2. Single piggyback variable level float switch, or double piggyback variable level float switch. Refer to FM0477.
3. Mechanical alternator M-Pak 10-0072 or 10-0075.
4. See FM0712 for correct model of electrical alternator.
5. Control switch 10-0225 used as a control activator specify duplex (3) or (4) float system.
6. Four hole J-Pak, junction box, for watertight connection or wired -in simplex or 2 pump operation, 10-0002.
7. Two hole J-Pak, for watertight connection or splice, 10-0003.
A CAUTION
For information on additional Zoeller products refer to catalog on Piggyback Variable Level Float Switches, FMO477; All installation of controls, protection devices and wiring should be done by a qualified licensed
Electrical Alternator, FM0486;Mechanical Alternator, FM0495;Sump/Sewage Basins, FM0487,and Single Phase Simplex Pump Control, FM1596; Alam1 System, FM0732. electrician. All electrical and safety codes should be followed including the most recent National
Electric Code (NEC) and the Occupational Safety and Health Act (OSHA).
RESERVE POWERED DESIGN
For unusual conditions a reserve safety factor is engineered into the design of every Zoeller pump.
MAIL T0: P.O. BOX 16347
Louisville, KY 40256-0347
LD � Manufacturers of. .
SNIP TO: 3649 Cane Run Road
a ® Louisville, KY 40211-1961
(502) 778-2731.1(800) 928-PUMP QvaLLTY PUMPS SNLE /.9,99"
http://www.zoeller.com P��� `0 FAX(502)774-3624
2060-00 Tax #1939-263-03-005
JOB NAME. Parcel #5, Diamond S ROULSTON
700 W. Diamond Star Ranch Rd.
Eagle, CO
JOB NO. V 11461
LOCATION
BILL TO
DATE STARTED
DATE COMPLETED
DATE BILLED
1I
ll.ti,( /
'
illy
)
CIN
q /o/
�
—
! v
161
l b 1 7L(,w a0-
tle"l -r'.'
K 4'o 0 Y01
OB COST SUMMAR
P
TOTAL SELLING PRICE
TOTAL MATERIAL
TOTAL LABOR
INSURANCE
SALES TAX
MISC. COSTS
TOTAL JOB COST
GROSS PROFIT
LESS OVERHEAD COSTS
% OF SELLING PRICE
NET PROFIT
-.00/
JOB r:olnER Product 278
JOB FOLDER Printed
In
u.SA