HomeMy WebLinkAbout661 Green Meadow Dr - 239122308001INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway -.Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1945-99 BP NO. OWNER: SCOTTY CATHCART PHONE: 970-923-6687 MAILING ADDRESS: 90 SAGE BRUSH LANE, ASPEN, CO 81611 APPLICANT: SAME PHONE: SYSTEM LOCATION: 661 GREEN MEADOW DRIVE, CARBONDALE, CO TAX PARCEL NO. 2391-223-08-001 LICENSED INSTALLER: STUTSMAN-GERBAZ, INC., CHARLES MONTOVER LICENSE NO. 9-99 PHONE: 970-923-2734 DESIGN ENGINEER: HIGH COUNTRY ENGINEERING, ROGER NEAL PHONE NO. 970-945-8676 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMT)M REQUIREMENTS FOR A 3 BEDROOM RESIDENCE &-mac ki v e A b5o rp-K ov1 /4recc. 1000 GALLON SEPTIC TANK 868 SQUARE FEET OF ABSORPTION AREA VIA 28 INFILTRATOR UNITS. AS PER ENGINEER'S DESIGN. SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN DATED 12/13/99. BE SURE TO MAINTAIN ALL APPLICABLE SETBACK REQUIRE- MENTS. ENGINEER IS RESPONSIBLE FOR FINAL INSPECTION. DO NOT BACKFILL ANY PART OF THE INSTALLATION UNTIL THE ENGINEER HAS INSPECTED AND APPROVED IT. BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS RECEIVED FINAL APPROVAL. � ENVIRONMENTAL HEALTH APPROVAL: J L'l a Atu Frj"t-i' DATE: DECEMBER 16, 1999 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 868 SQUAREFEET(VIA 28 Infiltrator Units ) INSTALLED Concrete TANK: 1000 GALLONS IS LOCATED DEGREES AND FEET INCHES FROM COMMENTS: AS BUILT RECEIVED FROM ENGINEER, DETAILS LOCATION OF INSTALLATION ON SITE. ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. ENVIRONMENTAL HEALTH APPROVAL /�1 ` DATE: 3`z3 /O6 -,— 1 yyy U--.; =;r r MLO'I:.r'HI_9LC t.:I_IUN I T r'[T,-) IItH '_! I l_'T. Ic;,dVU -'WJ I I I:I'LI'JE.1L9.5�"� H L J Ii':complete Applications Will NOT Be Accepted (Site Plan MUST be attached) ISDS Permit # Building Permit # APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. 0. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (El Jebel) **1-**#kj%ir**ic*�e**•kir*�ri*ir*kk*�eF*iek•kie*t•*tkt'!r*ie:kir*yF*ic*F•k*F•kk•krk•kit*�c�cF*•ie*�e•�etk•kY kPPLICATION FEE $150.00 PEkCGLATION TEST FEE $200.00 KE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER." , a ,.: k�c*-�#Y�r-A•�c****Yr*F•**•**ic�c•kic*#t*•;c*h•�:°k•k**9ct�r*k*•k�ir*k•**k9r'k*�•**•kkri:ti : -k* T�,DDRESS : _�d��e i�r� �� -- - txoNE :?®-23_-��a 7 Iff'/CONTACT PERSON : �� �l'��`.���c c.v ___ --- PHONE: SYSTEMS '-'0NTP1iCi'OR: �Ge b._�_ PHONE:`'2k: 2�.�._-t2'? 1 j ADDRE' S ��,uw_,_ , c� GSLI .rk�k*f�****•k•i�•*is*i•Ac:t:E'*'R�cic�c•k*k+icilc:tic*�1r,Fx*�F*irirx*�3r*'Y.�'�tc7E•k�r:k'x�*1-�'.,"•kn �'` _[ ,-i%TI` N IS FOR : (' NEW IiJS" AL A k ION ( A'�:TE T?'O r PRvrOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Lot Size: Pa:rce1 I t 1 P.adrp s s _ - , _ ____ __.__. _. __._..._......_- (Check applicable c ayiory) R „dential/Sinq_�e Fa lily Nunib:er of B droom.� '� ' 1 Number ;i hedro��ms Residential; i�l�_�I.ti-Fam,:..._Y Commercial/Iiidustrial* 'Type Jr WATER SUPPLY, app-ic:able- -aregc�rl') Well ( } Spring { ) surface U_ X) Public Name of Sl.zppl.ier: _require design by a Reg: si-ered 1-'Wofescic> Ial 211yi neer D ate * * A -k k -k * ie ;r * * is * * * * * * * -k * * * * •k- * *k * •k it ie * * #' �, * * * •k •le * ie tic i x •k * 'k # * is ie t' h is :F it •Jr it * .,. = R:t •k #- :k ,il C.10 dT PAID: 16D/ _ DATE RE r CHECK # : .... _— CASHIER: 1� Community Development Department (970) 328-8730 FAX (970) 328-7185 TDD (970) 328-8797 Email: eccmdeva@vail.net http: //www.eagle-county.com March 23, 2000 Mr. Scott Cathcart 90 Sage Brush Lane Aspen, CO 81611 EAGLE COUNTY, COLORADO Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 RE: Final of ISDS Permit #1945-99, Tax Parcel #2391-223-08-001. Property location: 661 Green Meadow Dr Basalt, CO. Dear Mr. Cathcart: This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Janet Kohl Environmental Health Department Eagle County Community Development ENCL: Informational Brochure Final ISDS Permit cc: files Community Development Department (970) 328-8730 FAX (970) 328-7185 TDD (970) 328-8797 Email: eccmdeva@vail.net http: //www.eagle-county.com EAGLE COUNTY, COLORADO Date: December 16, 1999 TO: Stutsman-Gerbaz, Inc. Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 FROM: Environmental Health Division RE: Issuance of Individual Sewage Disposal System Permit No. 1945-99. Tax Parcel # 2391-223-08-001; Property Location: 661 Green Meadow Drive, Carbondale, CO., Cathcart residence. Enclosed is your ISDS Permit No. 1945-99. It is valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County does not perform final inspections on engineer designed systems. Your TCO will not be issued until our office receives this certification. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files High Country Engineering, Roger Neal March 22, 2000 Ray Merry Eagle County Environmental Health Department P. O. Box 179 Eagle, CO 81631 Re: ISDS for the Cathcart Residence, Lot 1 Sopris Mesa Subdivision . HCE File Number 99004.40 Dear Ray: On March 21, 2000 High Country Engineering personnel observed the construction of the ISDS located at 0661 Green Meadow Drive, Lot 1 in the Sopris Mesa Subdivision. All of the components of the system had been installed, and only minor backfilling had taken place. A 1000 gallon septic tank and 28 standard Infiltrator units with inspection wells had been installed. The sewer pipe from the house had cleanouts installed, and the installation of the system was in conformance with the intent of the design. We are providing you with a drawing of the system as constructed with measurements to the major components of the system shown. If you have any questions, or need additional information, please contact us. Sincerely, HIGH COUNTRY ENGINEERING, INC. Roger D. Neal Principal Engineer RDN/ept cc: Scotty Cathcart �4i6kAL��E���� 923 Cooper Avenue 14 Inverness Drive East, Ste B-144 Glenwood Springs, CO 81601 Englewood, CO 80112 phone 970 945-8676 • fax 970 945-2555 phone 303 925-0544 • fax 303 925-0547 GEOTECHNICAL INVESTIGATION CATHCART RESIDENCE LOT 1, SOPRIS MESA SUBDIVISION EAGLE COUNTY, COLORADO Prepared For: Pat and Scotty Cathcart 90 Sage Brush Lane Aspen, CO 81611 Job No. GS-2905 November 15, 1999 CTL/THOMPSON, INC. CONSULTING ENGINEERS 234 CENTER DRIVE ■ GLENWOOD SPRINGS, COLORADO 81601 ■ (970) 945-2809 TABLE OF CONTENTS SCOPE SUMMARY OF CONCLUSIONS SITE CONDITIONS PROPOSED CONSTRUCTION SUBSURFACE CONDITIONS SITE EXCAVATION AND GRADING FOUNDATION FLOOR SYSTEMS AND SLABS -ON -GRADE BELOW -GRADE CONSTRUCTION SURFACE DRAINAGE PERCOLATION TESTING LIMITATIONS FIGURE 1 -APPROXIMATE LOCATIONS OF EXPLORATORY BORINGS FIGURE 2 - SUMMARY LOGS OF EXPLORATORY BORINGS FIGURES 3 AND 4 - SWELL- CONSOLIDATION TEST RESULTS FIGURE 5 - EXTERIOR FOUNDATION WALL DRAIN FIGURES 6 THROUGH 8 - PERCOLATION TEST RESULTS TABLE I - SUMMARY OF LABORATORY TEST RESULTS PAT AND SCOTTY CATHCART LOT 1, SOPRIS MESA SUBDIVISION CTL[T GS-2905 1 1 2 2 2 3 5 6 7 8 9 10 SCOPE This report presents the results of our soils and foundation investigation for the proposed Cathcart Residence on Lot 1, Sopris Mesa Subdivision in Eagle County, Colorado. We conducted the investigation to evaluate the subsurface conditions at the site and provide foundation recommendations for the proposed single family residence. Our report was prepared from data developed during our field exploration, laboratory testing, engineering analysis and our experience with similar conditions. This report includes a description of the subsurface conditions found in our exploratory borings, our opinions and recommendations for design criteria for recommended foundation and floor systems, and geotechnical and construction criteria for details influenced by the subsoils. The recommendations contained in the report were developed based on our understanding of the planned construction. Revisions to the anticipated construction could affect our recommendations. A summary of our conclusions is presented below. SUMMARY OF CONCLUSIONS 1. Subsurface conditions in our exploratory borings consisted of 0 and 0.5 foot of sandy clay "topsoil' underlain by silty to sandy clay with gravel and clayey gravel lenses to the total explored depth of 25 feet below existing ground surface. Basalt bedrock was encountered at 23 feet in TH-2. Practical drill rig refusal occurred on the bedrock at a depth of 24 feet. Free ground water was not found in our exploratory borings during drilling operations. 2. We recommend constructing the residence on footing foundations. Design and construction criteria for footings are presented in the report. 3. We judge potential differential movement of slabs -on -grade supported by the subsoils at this site will be low. Performance of slab -on -grade basement and garage floors will likely be good. 4. Surface drainage should be designed to provide for rapid removal of surface water away from the proposed residence.,,ossible`water flow° in the abandoned irrigation ditch should be diverted away from the proposed residence - PAT AND SCOTTY CATHCART LOT 1, SOPRIS MESA SUBDIVISION CTUT GS-2905 SITE CONDITIONS The site is within the Sopris Mesa Subdivision located north of El Jebel in Eagle County, Colorado. Lot 1 is located in the north part of development and northwest of Green Meadow Drive. The lot is situated in an open meadow which generally slopes gently down to the southeast. The building envelope is located in a slight swale with ground surfaces slope of about 5 percent. An abandoned, unlined irrigation ditch, approximately 1.5 feet deep, crosses the middle of the lot and building envelope and trends from the northeast to the southwest. No waterwas present in the ditch at the time of our investigation. Vegetation on the lot consists mainly of native grasses and sagebrush. Scrub oaks were located along the northeast border of the lot. PROPOSED CONSTRUCTION We anticipate the proposed single-family residence will be a two-story, wood - frame structure with a walk -out basement and an attached garage. The basement and garage floors will likely be constructed as slabs -on -grade. Foundation loads are expected to vary between 1,000 and 3,000 pounds per lineal foot of foundation wall with maximum interior column loads of 30 kips. We anticipate maximum excavation depths for the basement will be on the order of 6 to 8 feet deep. A percolation field= is planned south or southeast of the building.lf the construction will differ from the descriptions above, we should be informed so we can check that our recommendations and design criteria presented herein are appropriate. SUBSURFACE CONDITIONS Subsurface conditions for the proposed building were investigated by drilling two exploratory borings (TP-1 and TP-2) with a track -mounted drill rig at the approximate locations shown on Figure 1. We also drilled one profile boring (Profile) and three percolation borings (P-1 through P-3) in the planned area of the percolation PAT AND SCOTTY CATHCART LOT 1, SOPRIS MESA SUBDIVISION CTUT GS-2905 2 0 field. Excavation was directed by our representative who logged the soils and bedrock encountered in the borings and obtained samples. Samples obtained in the field were returned to our laboratory where field classifications were checked and typical samples selected for testing. Graphic logs of the soils encountered in our exploratory borings are shown on Figure 2. Results of swell -consolidation tests are shown on Figures 3 and 4 and results of laboratory testing summarized on Table I. Subsurface conditions in our exploratory borings consisted of 0 and 0.5 foot of sandy clay "topsoil' underlain by silty to sandy clay with gravel and clayey gravel lenses to the total explored depth of 25 feet below existing ground surface. Basalt bedrock was encountered at 23 feet in TH-2. Practical drill rig refusal occurred on the bedrock at a depth of 24 feet. Free ground water was not found in our exploratory borings during drilling operations. Results of field penetration resistance tests and observations during drilling indicated the clays were stiff to very stiff and moisture contents were slightly moist to moist. Two samples of the clays selected for one-dimensional, swell -consolidation testing exhibited 2.4 percent compression and no movement when wetted under an applied pressure of 1,000 psf. SITE EXCAVATION AND GRADING Grading plans were not available at the time of this investigation. We anticipate the residence will be stepped into the natural slope of the site to create a walk -out basement on the southeast side of the residence. Excavation depths on the order of 6 to 8 feet may be required to reach foundation elevations at the northwest of the building. Fill may be required to achieve construction grades below some parts of the residence. Areas which will receive fill should be stripped of vegetation, organic soils and debris. The 'resulting surface should be scarified to a depth of at least 8 inches, moisture conditioned to within 2 percent of optimum moisture content and compacted to at least 95 percent of maximum standard Proctor (ASTM D 698) dry PAT AND SCOTTY CATHCART LOT 1, SOPRIS MESA SUBDIVISION CTUT GS-2905 3 LM7 density. The soils in the abandoned irrigation ditch should be excavated to form a rectangular shaped trench which extends laterally at least 1 foot outside the existing ditch. The excavation should be deep enough to remove all soft soils in the bottom of the ditch. The on -site soils free of organic matter, debris and rocks larger than 6 inches in diameter can be used as fill. Fill should be placed in loose lifts of 10 inches thick or less, and moisture conditioned to within 2 percent of optimum moisture content. Fill for site grading placed outside the building footprint should be compacted to at least 95 percent of maximum standard Proctor (ASTM D 698) dry density. Structural fill placed below the building footprint should be compacted to 98 percent of maximum ASTIVI, D 698 dry density. Placement and compaction of fill should be observed and tested by a representative of our firm during construction. We anticipate excavations for the foundations and utilities can be accomplished using conventional, heavy-duty excavation equipment. Excavation sides will need ',to be sloped or braced to meet local, state and federal safety regulations. Wei believe the on -site soils will classify as a Type B soil based on OSHA standards governing excavations. Temporary slopes above ground water should be no steeper than 1 to 1 (horizontal to vertical) in Type B soils. Contractors should identify the soils encountered in the excavation and refer to OSHA standards to determine appropriate slopes. Soils removed from an excavation should not be stockpiled at the edge of the excavation. We recommend the excavated soils be placed at a distance from the top of the excavation equal to at least the depth of the excavation. Free ground water was not encountered in our exploratory borings during drilling operations. We do not anticipate excavations for foundations or utilities will penetrate ground water, however, ground water levels may vary with seasonal conditions and time of year. If free ground water is encountered, dewatering can PAT AND SCOTTY CATHCART LOT 1, SOPRIS MESA SUBDIVISION CTUT GS-2905 4 likely be accomplished by sloping the excavations to a gravity discharge or to a temporary sump',, where water can be removed by pumping. The ground surrounding the excavations should be sloped to direct runoff away from the excavation. FOUNDATION Our exploratory borings indicate soils present at anticipated foundation levels will consist of predominantly silty to sandy clays. The abandoned irrigation ditch Within the building footprint should be excavated and backfilled with densely compacted, structural fill as described in SITE EXCAVATION AND GRADING. The owner should confirm that it is not possible for water to be directed into the ditch from upstream sources or provide the means to divert water flow away from the R,roposed residence. We recommend constructing the residence on footings foundations supported by the native clays or densely compacted, structural fill. If footings in some parts of the building are supported on native soils and footings in some parts are supported on structural fill, increased differential movement of foundations is likely. We recommend limiting the thickness of fill under footings to 3 feet or less. We anticipate total settlements of about 1 inch may occurwith differential settlement of about '/2 inch. The footings should be designed and constructed with the following criteria: 1. The footing foundations should be supported on the native clays or densely compacted, structural fill. Soils loosened during the excavation or forming process for the footings should be removed or the soils can be re -compacted prior to placing concrete. 2. Footings should be designed for a maximum soil bearing pressure of 2,000 psf. 3. Continuous wall footings should have a minimum width of at least 18 inches. Foundations for isolated columns should have minimum dimensions of 24 inches by 24 inches. Larger sizes may be required, depending upon foundation loads. PAT AND SCOTTY CATHCART LOT 1, SOPRIS MESA SUBDIVISION CTL/T GS-2905 5 4. Grade beams and foundation walls should be well reinforced, top and bottom, to span undisclosed loose or soft soil pockets. We recommend reinforcement sufficient to span an unsupported distance of at least 10 feet. Reinforcement should be designed by the structural engineer. 5. The soils under exterior footings should be protected from freezing. The depth normally assumed for frost protection in the area is to 42 inches. The local building department should be consulted to verify the required depth. 6. The completed foundation excavation should be checked by a representative of our firm, prior to placing forms, to confirm that subsoils are as anticipated and suitable for support of designed footings. FLOOR SYSTEMS AND SLABS -ON -GRADE Floors in the basement and garage will likely be constructed as slabs -on - grade. Based on our laboratory test data and our experience, we believe slab -on - grade construction supported by the subsoils at this site will involve low potential risk of movement and associated damage. Floor slabs may experience some differential movement and associated damage if some portions of slabs are supported by the natural clays and some portions are supported on fill. If fill thicknesses of 3 feet or more are required to obtain construction grades under parts of the building, we recommend supporting slabs -on -grade entirely on a uniform thickness of fill in order to minimize differential movement. The mostpositive method to mitigate floor movement is the construction of a structural floor with an air space between the floor and the subgrade soils. The structural floor is supported by the foundation system. Structural floors are an excellent choice from a geotechnical viewpoint. If some differential floor slab movement and associated cracking is not tolerable a structurally supported floor should be constructed. PAT AND SCOTTY CATHCART LOT 1, SOPRIS MESA SUBDIVISION CTL/T GS-2905 C We recommend the following precautions for slab -on -grade construction at this site. These precautions will not prevent movement from occurring, they tend to reduce damage if slab movement occurs. Future owners should be advised of the potential for movement of slab -on -grade floors and these precautions. 1. Slabs should be placed directly on the exposed subsoils. Provision of a sand or gravel layer under slabs is not recommended because it increases the possibility of a single source of water wetting the entire area supporting the slab. 2. Slabs should be separated from exterior walls and interior bearing members with a slip joint which allows free vertical movement of the slabs. 3. Underslab plumbing should be eliminated where feasible. Where such plumbing is unavoidable, it should be pressure tested for leaks before the slab is constructed. Plumbing and utilities which pass through slabs should be isolated from the slabs. Gas and water lines leading to I slab -supported appliances should be provided with flexible couplings. 4. Exterior patio and porch slabs should be isolated from the residence. These slabs should be well -reinforced to function as independent units. Movements of these slabs should not be transmitted to the residence foundations. 5. Frequent control joints should be provided to reduce problems associated with shrinkage and curling. Our experience indicates panels which are approximately square generally perform better than rectangular areas. We advocate use of an additional joint about 3 feet away from and parallel to foundation walls. BELOW -GRADE (,CONSTRUCTION Basement walls should be designed for lateral earth pressures. The design lateral earth pressure is dependent upon the type of backfill. Assuming the on -site soils are used as: backfill, we recommend design of basement walls to resist an "at - rest" lateral earth pressure calculated using an equivalent fluid density of at least 45 pcf for this site. This equivalent density does not include allowances for sloping backfill, surcharges or hydrostatic pressures. The structural engineer should also PAT AND SCOTTY CATHCART LOT 1, SOPRIS MESA SUBDIVISION CTL/T GS-2905 7 0 consider site specific grading and the effects of large openings on the behavior of the walls. Backfill placed adjacent to foundation wall exteriors should be moisture conditioned to within 2 percent of optimum moisture content and compacted to at least 95 percent', of maximum standard Proctor (ASTM D 698) dry density. Water from rain, snow melt and surface irrigation of lawns and landscaping frequently flows1through relatively permeable backfill placed adjacent to a residence and collects on the surface of relatively impermeable soils occurring at the bottom of the excavation. This can cause wet or moist basement conditions after construction. To reduce the likelihood water pressure will develop outside foundation walls and reduce risk of accumulation of water at the basement level, we recommend provision of a foundation drain. The drain should consist of a 4-inch diameter, open joint orslotted pipe encased in free draining gravel. The drain should lead to a positive gravity outlet, or to a sump pit where water can be removed by pumping. Gravity outlets should not be susceptible to clogging or freezing. A typical foundation drain detail is presented on Figure 5. SURFACE DRAINAGE Surface drainage is critical to the performance of foundations and concrete flatwork. We recommend the following precautions be observed during construction and maintained at all times after the residence is completed: 1. Wetting or drying of the open foundation excavation should be avoided. 2. The ground surface surrounding the exterior of the residence should be',sloped to drain away from the residence in all directions. We recommend providing a slope of at least 12 inches in the first 10 feet around the residence, where possible. In no case should the slope be less than 6 inches in the first 5 feet. We recommend incorporating a drainage swale above the residence to direct surface water around the residence. PAT AND SCOTTY CATHCART LOT 1, SOPRIS MESA SUBDIVISION CTL/T GS-2905 0 3. The residence should be provided with gutters and downspouts. Snow should not be allowed to accumulate adjacent to the residence. 4. Roof downspouts and drains should discharge well beyond the limits of all backfill. Splash blocks and downspout extensions should be provided at all discharge points. We specifically recommend against burying downspout discharge pipes because it increases the potential for, subsurface wetting near the foundation. 5. 6. (fill around the exterior of foundation walls should be moistened compacted to at least 95 percent of maximum standard Proctor 'M D 698) dry density. dscaping should be carefully designed to minimize irrigation. its used near foundation walls should be limited to those with low sture requirements; irrigated grass should not be located within 5 of the foundation. Sprinklers should not discharge within 5 feet he foundation and should be directed away from the building. lation should be limited to the minimum amount sufficient to ntain vegetation; the application of additional water will increase likelihood of slab and foundation movements. 7. Impervious plastic membranes should not be used to cover the ground surface immediately surrounding the residence. These membranes tend to trap moisture and prevent normal evaporation from occurring. Geotextile fabrics can be used to control weed growth and allow some evaporation to occur. PERCOLATION TESTING We drilled three percolation borings (P-1 through P-3) and one profile boring (Profile) in the planned area of the percolation field at the approximate locations shown on Figure I1. Graphic logs of the subsoils exposed in the borings are shown on Figure 2. Results of our percolation tests are shown on Figures 6 through 8. Percolation test results indicate that a design percolation rate will be on the order of 15 to 30 minutes per inch. We recommend the percolation field be designed by an engineer qualified in septic field design such as Church and Associates, (303) 463-9317. PAT AND SCOTTY CATHCART LOT 1, SOPRIS MESA SUBDIVISION CTL/T GS-2905 ti u LIMITATIONS Our exploratory borings were spaced to obtain a reasonably accurate picture of subsurface conditions. Variations in the subsurface conditions not indicated by our borings will Ioccur. We should observe the completed foundation excavation to confirm the soils are as anticipated from our exploratory borings and suitable for support of the designed footings. Our report was based on conditions disclosed by our exploratory borings, engineering analysis and our experience. Criteria presented reflect our understanding of the proposed construction. We should be advised if the final design differs from our assumptions to permit us to re-evaluate our conclusions and recommendations. This investigation was conducted in a manner consistent with that level of care and skill ordinarily exercised by geotechnical engineers currently practicing under similar conditions in the locality of this project. No other warranty, express or implied, is made. If we can be of further service in discussing the contents of this report or in the analysis of the influence of the subsoil conditions on the design of the structure, please call. CTUTHOMPSON, INC. "IffJ s D. Kellogg Sta Geotechnical Engineer Keviewe Jo n �tg, P.E. a B an abage i e M J F 0° � �t .F (3 copies sen PAT AND SCOTTY CATHCART LOT 1, SOPRIS MESA SUBDIVISION CTUT GS•2905 10 CATHCART RESIDENCE LOT 19SOPRIS'I MESA SUBDIVISION EAGLE COUNTY, COLORADO Scale: 1 "-80' APPROXIMATE LOCATIONS OF EXPLORTORY BORINGS Job No. GS-2905 Fig. 1 C- 0 0• z 0 c� I N c0 O N Frr Depth In Feet c N O 0 0 O (n O h 4eeJ ul 44d9a m I N to \ N O "O N W N m o z a a. z r*i ?.to S. ci °A4D3� 0 m m Jrm Q.art. 0 X-0 7� O Xto 13MG I ° c0 n ao "; o CA w aso cn o. c a;�c 0 ° a. Co. a- -4. -► AOQ 30 07(p� o 3 a (n o- ;n Q a a- c ccm OWN G-0 C O Q. c° �tn� 3 3.� — -n anG0 0C'sa 4 a mo o ° 0.0 -h 00. mac �0 m�a. a m �. a �- 0 � i a a. Of Of z O -q m U) N O -H Depth In Feet tJ� p CA V W CO N N N N N O V. lees ul 44dea v 0 a. �*. m 300 a a 3.050 a m�3sv aim m N O 0) �aacm a�.�orn aco013co . a W Q' NO0 O =r c N 1�1 tip 3m o'c00 3 O con— n � �� .°� °. cn r co a c `0 Q. ci �� A 3-.m0 3m0 c-< < co A _° ca S u 0 fA O -F 0 3 �T u0 '0 a. 0 a r-o a o to m s Y S -,. m a rn ° �<� a. r U 0 rrl C m z v 6 5 4 3 2 z 0 05 z 1 Q a x w 0 0 z 0 7) w ' IX a V2 -4 -5 -6 _7 0.1 Sample of CLAY, SANDY (CL) From TH 1 AT 9 FEET JOB NO, GS-2905 RESSION UN URE DUE TO 1.0 10 APPLIED PRESSURE - KSF NATURAL DRY UNIT WEIGHT= NATURAL MOISTURE CONTENT= 100 94 PCF 11.0 % Swell Consolidation Test Results FIG. 3 7 s 5 4 3 E z O N z i a IL x W 0 0 z O W ' Ix a M V2 0.1 Sample of CLAY, SANDY (c From TH 2 AT 4 FEET JOB NO. GS-2905 U E TO 1.0 10 APPLIED PRESSURE - KSF NATURAL DRY UNIT WEIGHT= NATURAL MOISTURE CONTENT= M 100 105 PCF 8.3 % Swell Consolidation Test Results FIG. 4 CL' .................. NOTE: SLOPE DRAIN SHOULD BE AT LEAST 2 INCHES PER REPORT BELOW BOTTOM OF VOID AND FOOTING AT THE HIGHEST POINT AND SLOPE DOWNWARD TO A POSITIVE GRAVITY OUTLET OR TO A SUMP WHERE WATER CAN BE REMOVED BY PUMPING. BACKFILL--) PROVIDE PVC SHEETING GLUED TO FOUNDATION WALL TO REDUCE BELOW GRADE WALL MOISTURE PENETRATION. SLOPE ENCASE PIPE IN WASHED REINFORCING STEEL PER CONCRETE AGGREGATE (ASTM PER STRUCTURAL OSHA C33, NO. 57 OR NO. 67). DRAWINGS. EXTEND GRAVEL TO AT LEAST 1/2 HEIGHT OF FOOTING. PROVIDE POSITIVE SLIP JOINT BETWEEN SLAB AND WALL. COVER GRAVEL WITH FLOOR SLAB FILTER FABRIC OR ..... ..:...... .............................................. • •::: t :•::..::. ROOFING FELT. in ;::: r—FOOTING OR PAD —� 2" MINIMUM 8" MINIMUM I--- OR BEYOND 1:1 SLOPE FROM BOTTOM OF FOOTING. (WHICHEVER IS GREATER) 4—INCH DIAMETER PERFORATED DRAIN PIPE. THE PIPE SHOULD BE LAID IN A TRENCH WITH A SLOPE RANGING BETWEEN 1/8 INCH AND 1/4 INCH DROP PER FOOT OF DRAIN. JOB NO. GS-2905 SLOPE TO DRAIN Exterior Foundation Wall Drain FIG. 5 SATURATION AND PREPARATION PERCOLATION TEST DATE: 11 /03/99 DATE: 11 /04199 TIME AT START OF SATURATION: 4:15pm WATER IN BORING AFTER 24 HOURS YES X NO PERCOLATION TEST RESULTS HOLE NUMBER DEPTH (INCHES) TIME AT START OF INTERVAL TIME INTERVAL (MINUTES) DEPTH TO WATER CHANGE IN WATER DEPTH (INCHES) PERCOLA- TION RATE (MIN/INCH) START OF INTERVAL (INCHES) END OF INTERVAL (INCHES) P-1 46 10:56 10 0.0 8.5 8.5 1 11:06 10 8.5 12.0 3.5 3 11:16 10 12.0 14.5 2.5 4 11:26 10 14.5 16.5 2.0 5 11:36 10 16.5 18.5 2.0 5 11:46 10 18.5 20.0 1.5 7 12:01 15 20.0 22.0 2.0 8 12:16 15 22.0 24.0 2.0 8 12:31 15 24.0 25.5 1.5 10 12:46 15 25.5 27.0 1.5 10 1:01 15 27.0 28.5 1.5 10 1:16 15 28.5 29.5 1.0 15 1:31 15 29.5 30.5 1.0 15 1:46 15 30.5 31.5 1.0 15 Job No. GS-2906 Fig. 6 SATURATION AND PREPARATION DATE: 11 /03/99 TIME AT START OF SATURATION: 4:15pm PERCOLATION TEST DATE: 11/04/99 WATER IN BORING AFTER 24 HOURS YES X NO PERCOLATION TEST RESULTS HOLE NUMBER DEPTH (INCHES) TIME AT START OF INTERVAL TIME INTERVAL (MINUTES) DEPTH TO WATER CHANGE IN WATER DEPTH (INCHES) PERCOLA- TION RATE (MIN/INCH) START OF INTERVAL (INCHES) END OF INTERVAL (INCHES) P-2 46 10:51 10 0 4.5 4/5 2 11:01 10 4.5 7.25 2.75 4 11:11 10 7.25 9.5 2.25 4 11:21 10 9.5 12.0 2.5 4 11:31 10 12.0 14.0 2.0 5 11:41 10 14.0 16.0 2.0 5 11:56 15 16.0 18.5 2.5 6 12:11 15 18.5 21.0 2.5 6 12:26 15 21.0 23.0 2.0 8 12:41 15 23.0 24.5 1.5 10 12:56 15 24.5 26.0 1.5 10 1:11 15 26.0 27.0 1.0 15 1:26 15 27.0 28.0 1.0 15 1:41 15 28.0 29.0 1.0 15 Job No. GS-2905 Fig. 7 FDATE- ION AND PREPARATION PERCOLATION TEST DATE: 11/04/99 /03199 WATER IN BORING AFTER 24 HOURS TIME AT START OF SATURATION: 4:15pm YES X NO PERCOLATION TEST RESULTS DEPTH TO WATER NGE PERCOLA- HOLE I DEPTH NUMBER (INCHES) P-3 1 45 TIME AT TIME START OF (MINUTES) ERVAL INTERVAL 10:48 10:58 11:08 11:18 11:28 11:38 11:53 12:08 12:23 12:38 12:53 1:08 1:23 1:38 10 10 10 10 10 10 15 15 15 15 15 15 15 15 CHA IN WATER TION START OF END OF DEPTH (MINI INTERVAL INTERVAL (INCHES) (INCHES) 0 4.5 4.5 2 4.5 7.0 2.5 4 7.0 9.0 2.0 5 9.0 11.0 2.0 5 11.0 12.5 1.5 7 12.5 13.5 1.0 10 13.5 15.5 2.0 8 15.5 16.5 1.0 15 16.5 17.5 1.0 15 17.5 18.5 1.0 15 18.5 19.5 1.0 15 19.5 20.5 1.0 15 20.5 21.0 0.5 30 21.0 21.5 0.5 30 Fig. 8 Job No. GS-2905 SATURATION AND PREPARATION PERCOLATION TEST DATE: 11/03/99 TIME AT START OF SATURATION: 4:15pm DATE: 11/04/99 WATER IN BORING AFTER 24 HOURS YES X NO PERCOLATION TEST RESULTS Job No. GS-2905 Fig. 7 SATURATION AND PREPARATION PERCOLATION TEST DATE: 11 /03/99 DATE: 11 /04/99 TIME AT START OF SATURATION: 4:15pm WATER IN BORING AFTER 24 HOURS YES X NO PERCOLATION TEST RESULTS HOLE NUMBER DEPTH (INCHES) TIME AT START OF INTERVAL TIME INTERVAL (MINUTES) DEPTH TO WATER END OF INTERVAL (INCHES) CHANGE IN WATER DEPTH (INCHES) PERCOLA- TION RATE (MIN/INCH) START OF INTERVAL (INCHES) P-3 45 10:48 10 0 4.5 �4.5 2 10:58 10 4.5 7.0 9.0 2.5 4 11:08 10 7.0 2.0 5 11:18 10 9.0 11.0 2.0 5 11:28 10 11.0 12.5 1.5 7 11:38 10 12.5 13.5 1.0 10 11:53 15 13.5 15.5 2.0 8 12:08 15 15.5 16.5 1.0 15 12:23 15 16.5 17.5 1.0 15 12:38 15 17.5 18.5 1.0 15 12:53 15 18.5 19.5 1.0 15 1:08 15 20.5 1.0 15 1:23 15 EE4 21.0 21.5 0.5 30 1:38 15 0.5 30 Job No. GS-2905 Fig. 8 W J m a F- U) F- J M U) W w F- CO W F- 0 F- a 0 m a J LL 0 a I 0) M 0 O C T 0 0 a A) M o_ m c cc cu m rn c N 3 0 a� a 3 0 Z 1945-99 Tax #2391-223-08-001 Lot #1, Sopris Mesa CATHCART JOB NAME Aspen Mountain View 661Green Meadow Drive JOB NO. 07 B LOCATION BILL TO DATE STARTED DATE COMPLETED DATE BILLED 1 l(l qq�� 1 Z 1 o Z L - �� '� �, JOB COST SUMMARY 5 TOTAL SELLING PRICE ca TOTAL MATERIAL TOTAL LABOR INSURANCE SALES TAX MISC. COSTS TOTAL JOB COST GROSS PROFIT LESS OVERHEAD COSTS % OF SELLING PRICE NET PROFIT JOB FOLDER Product 277 F JOB FOLDER Printed in USA 1 /� C a �r �R 3 _ �i W/k [ if ♦f 20, `_ ILLrrr~�`t t if ' 1 •` , i . i �• 1 > -ice N. j _ 4 ��r '' • �1 f ` _ I5 � � ; _ _. €_ � - i � e `���` s•• -- - f'� J�^ r 'F'� ^-4__--I{t lip - - - � ° � 'r _ , :. • 1 . � tom— —1i� � ` � f { I Lam. � e ? 1 � �f `�-- � � • � � � � • 1�� i` : �t a r 0 r-' %� r. FENDER CANE' r� • %j • y!n _ t i - ' i �_ • Z � i �� - f- a� s-� �� =� r, _ �`-�-` � , = � - 4 _ t r, f gyp; ; \ ? ,;� ti '�;'��ik'_-- =y - �_s=-#��� rl ;,s�•r�f�f i� 1 ��j' y\ _ i,� _ .�F �f �� J� �� k •f`'_i 7a — tj /- fir/ 41 J. CUT HOLE IN TOP OF INFILTRATOR UNIT f f14 FOR INSTALLATION OF INSPECTION WELL 4- -PIPE 114 ' \ SOLID PIPE R19- -�Ukr f COUPLING ' ���/V _\ _ op O 4' 0 PERFORATED PIPE MF�T ` E OPE WRAPPED IN FILTER FABRIC O SOUD CAP FOR SUPPORT ON � � I BOTTOM OF TRENCH OR BED GENERAL NOTES ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE EAGLE COUNTY AND COLORADO DEPARTMENT OF HEALTH (COON) REGULATIONS OF INDIVIDUAL I Z`f SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE f APPROXIMATES �` ,, �` INSPECTION WELL DETAIL RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN PROPOSED \ �_ f ; BUILDING FOOTPRINT THE ABOVE -MENTIONED REGULATIONS. i 3 BEDROOM � �- ., `� N.T.S. - �� -�4 _ -FLOW: BEDROOMS •2 PERSONS BEDROOM *75 GALLONS/PERSON/DAY-IS- :' 32 5. =_ - \ - - - - DAILY FLOW - MAXIMUM L 3 _ - � 450 GPD AVERAGE - \ CLEANOUT MAXIMUM = 1.5* AVERAGE = 675 GPD SEPTIC TANK: MINIMUM PRE -CAST CONCRETE TANK SIZE ACCORDING TO CALCULATION IS 844 GALLONS: ;EAGLE COUNTY REQUIRES A 3 BEDROOM HOUSE \ - NATURAL BACKFILL TO HAVE A MINIMUM 1000 GALLON TANK. (MINIMUM TANK FOR 4 BEDROOM - 1250 GAL.) RECOMEND A 1250 GAL. TANK FOR, FUTURE EXPANSION, 1000 GAL IS ACCEPTABLE. 12' MIN. COVER pR - *FIELD SIZE: PER CDOH EQUATIONS: 36" MAX. COVER A = Q� Q =MAX IMUM FLOW g _ _ 5 t PERCOLATION RATE 30 A = 675 * 30 = 740 SQ . FT - 10 5 SIDES ROUGHENED PER CDOH BEGS FOR USE OF *INFILTRATOR* TRENCH .SYSTEMS ` ABSORPTION AREA CAN BE REDUCED BY 50% FOR TRENCH CONFIGURATION ' L 1 CLEANOUT OT/ UNITS REQUIRED = 740 S.F. • 0.5 / 15.5 S.F./UNIT = 23.87 UNITS '. A. �\ \� 12- MINIMUM 24 UNITS. EAGLE COUNTY RECOMENDED A LOADING RATE OF Q S —- i�� 0.8 GAL/S.F: 675 GPD/ 0.8 GAL/S.F. s 0.5 / 15.5 S.F./UNIT O J f4 615 �� 1000 GALLON 27.2 UNITS. RECOMEND 28 UN ITS. 1 ? SEPTIC TANK - 1 O / - �- ` - 1 �\ ��\ ��\ ��\ �\ �\ \ �\� 3 PRESOENT , - SOIL EXCAVATED FROM SITE ACCEPTABLE IF NO CLAY IS ;' AC+ 4. VEHICULAR TRAFFIC IS PROHIBITED ON -THE FIELD AREA. INFILTRATOR UNIT I TRENCH BOTTOM LEVEL 5. CLEANOUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100 NATURAL GROUND 24" AND ROUGHENED FEET ALONG THE HOUSE SEWER'; 6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN 1/2-FOOT OF FINAL GRADE. r ? = INSPECTION WELL \ / TI 0 N(TYP.) 7. LOCATIONS OF ALL COMPONENTS MAYBE VARIED AS NECESSARY AS LONG TRENCH CROSS SEC ,.. AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE. REQUIRED. -- - - 1 N.T.S. ti atiS r 8. USOINGDDRAOtNAGEVSWARESNASENOEFCESSARYSURFACE WATER AWAY FROM AREA O O �Ilkv9�F 9. PERCOLATION RATE BASED ON TESTING BY CTL/THOMPSON, INC. ON NOVEMBER t , y yx ` 15, 1999, JOB NUMBER GS-2905. 10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. `PERMIT UNDISTURBED / MUST BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. 't I \ / ENGINEER MUST OBSERVE CONSTRUCTED SYSTEM BEFORE BACKFILL _ CTION WELL EARTH F AND PROVIDE REPORT TO COUNTY. ►- i11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR I{ I FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. mGENERAL ABSORPTION TRENCH NOTES 1. TRENCH LENGTH SHALL NOT EXCEED 100 FEET. F f F - 4=166 `� : / � \ "•.`, 2. THE BOTTOM OF EACH TRENCH SHALL BE LEVELCu - � L _ � � / _ 3. DRAINAGE DITCHES ARE 70 BE PROVIDED ABOVE AND AROUND TRENCHES, - .. AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING: ABSORPTION AREA. 1 Fr � `.; `_. � �.� , 4. TRENCHES SHALL FOLLOW CONTOURS. - t 5. INSTALL INFILTRATOR IN ACCORDANCE WITH MANUFACTURES RECOMMENDATIONS. r r Z W O Q Z Z) - O _ U = W J Z O Q Z = W W (2 w W W a w w (Z' N Q Z O W F W � o - w V ILL U W o a Z O _ Q Z _ d p - LU a: to O rn a� Z mto 0 w d n cv Ln - w a' I w ~ J W Y Q