HomeMy WebLinkAbout302 Strohm Cir - 211106405023INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway • Eagle, CO 81631
Telephone: (970) 328-8755
COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1915-99 BP NO. TOWN OF GYPSUM
OWNER: RUSTY BOSSOW PHONE: 970-524-9757
MAILING ADDRESS: P.O. BOX 4202, GYPSUM, CO 81637
APPLICANT: SAME PHONE:
SYSTEM LOCATION: 302 STROHM CIRCLE, GYPSUM, CO TAX PARCEL NO. 2111-064-05-023
LICENSED INSTALLER: BOSSOW EXCAVATING, REX BOSSOW LICENSE NO. 15-99 PHONE: 970-524-9888
DESIGN ENGINEER: PHONE NO.
INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 4 BEDROOM RESIDENCE
1250 GALLON 2-COMPARTMENT SEPTIC TANK 1125 SQUARE FEET OF ABSORPTION AREA VIA 37 CHAMBERED UNITS AS REQUESTED BY INSTALLER
SPECIAL REQUIREMENTS: INSTALL IN SERIAL DISTRIBUTION IN TRENCHES, WITH A CLEANOUT BETWEEN THE TANK AND THE HOUSE AND IN-
SPECTION PORTALS IN EACH TRENCH. RAKE ALL TRENCH SURFACES TO PREVENT SMEARING OF SOILS AND DO NOT INSTALL IN WET WEATHER.
CALL EAGLE COUNTY ENVIRONMENTAL HEALTH FOR FINAL INSPECTION PRIOR TO BACK FILLING ANY PART OF THE INSTALLATION OR
WITH ANY QUESTIONS REGARDING THE INSTALLATION. BUILDING TEMPORARY CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE
SEPTIC SYSTEM HAS RECEIVED FINAL APPROVAL.' /
ENVIRONMENTAL HEALTH APPROVAL: (d DATE: SEPTEMBER 22 1999
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS,
ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING
REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL
AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO
BE LICENSED.
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM
IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: 1125 SQUAREFEET(VIA 37 STANDARD INFILTRATOR UNITS )
INSTALLED POLYETHYLENE SEPTTrANK: 1250 GALLONS IS LOCATED 30 DEGREES AND 19 FEET INCHES
FROM THE. CT,RANOUT ON THE NORTH SIDE OF THE HOUSE.
COMMENTS: FTNAT, TNSPF.CTTON PERFORMED BY HEATHER SAVAT OX ON SEPTEMBER 30 1999.
ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS
COMPLETED.
ENVIRONMENTAL HEALTH APPROVAL ��VI% DATE: OCTOBER S, 1999
Incomplete Applications Will'NOT Be Accepted
(Site Plan MUST be attached) 9
ISDS Permit # —� J
Building Permit #
AP_PLICA_TION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE..- EAGLE COUNTY
P. 0. BOX 179
EAGLE, CO 81631
328-8755/927-3823 (El Jebel)
* PERMIT APPLICATION FEE -$150.00 PERCOLATION TEST FEE $200.00
*
*
* MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER"
PROPERTY OWNER: - ,r
® l `<� t
MAILING ADDRESS: ��� PHONE:
�(R
APPLICANT/CONTACT PERSON: d 4 / PHONE:
" p t14 , tg PHONE:
LICENSED SYSTEMS CONTRACTOR:
COMPANY/DBA: !IX (ADDRESS:�
PERMIT APPLICATION IS FOR: AA NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
LOCATION OF PROPOSED INDIVIDUAL SEWAGE ISPOSA(L� SYST M:
Legal Description: e q �� v -14
`Tax Parcel Number: 4 ut 0,691 _ Lot Size :
Physical Address:
BUILDING TYPE: (Check applicable category)
(`,4 Residential/Single Family Number of Bedrooms
( ) Residential/Multi-Family* Number of Bedrooms
( ) Commercial/Industrial* Type
TYPE OF WATER SUPPLY: (Check applicable category)
Well ( ) Spring ( ) Surface54 ���
Public Name of Supplier: 'G'n^
*These systems require design by a Registered Professional Engineer
SIGNATURE: Date:
*****************************************I*********************g*************
AMOUNT PAID: RECEIPT #: l` 3� q DATE: < ��
CHECK #: -7 ?,-X CASHIER:
Community Development Department
(970) 328-8730
FAX (970) 328-7185
TDD (970) 328-8797
Email: eccmdeva@vail.net
http: //www.eagle-county.com
EAGLE COUNTY, COLORADO
DATE: September 22, 1999
TO: Bossow Excavating
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
FROM: Environmental Health Division
RE: Issuance of Individual Sewage Disposal System Permit 91915-99, Tax Parcel
#2111-064-05-023. Property. Location: 302 Strohm Circle, Gypsum, CO.,
Bossow residence.
Enclosed is your ISDS Permit No. 1915-99. It is valid for 120 days. The enclosed copy of the
permit must be posted at the installation site. Any changes in plans or specifications invalidates
the permit unless otherwise approved.
Also enclosed is the ISDS Final Inspection Completeness Form. The items on this form need
to be completed before you call for your final inspection. Also, please note any special
conditions which may have been placed on the permit. Do not back fill any part of the
installation until it has been inspected. If all items are not completed, a reinspection fee of
$42.50 must be paid before a reinspection is made.
Please call our office well in advance to allow for scheduling of final inspection. Your building
permit TCO will not be issued until final approval has been given for the ISDS Permit.
Permit specifications are minimum requirements only, and should be brought to the property
owner's attention.
This permit does not indicate conformance with other Eagle County requirements.
If you have any questions, please feel free to contact the Environmental Health Division at 328-
8755.
cc: files
Enclosures: ISDS permit # 1915-99; ISDS Final Inspection Completeness Form
Post -it`" Fax Note
7671
Date
pages a
To
From
Co./De
Co.
Phone #
Phone #
p ��
�t1
Fax #
Fax #
Community Development Department
(970) 328-8730
FAX (970) 328-7185
TDD (970) 328-8797
Email: eccmdeva@vail.net
http: //www.eagle-county.com
October 8, 1999
Rusty Bossow
P.O. Box 4202
Gypsum, CO 81637
EAGLE COUNTY, COLORADO
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
RE: Final of ISDS Permit #1915-99, Tax Parcel #2111-064-05-023. Property location: 302
Strohm Circle, Gypsum, CO.
Dear Mr. Bossow:
This letter is to inform you that the above referenced ISDS Permit has been inspected and
finalized. Enclosed is a copy to retain for your records. This permit does not indicate
compliance with any other Eagle County requirements. Also enclosed is a brochure regarding
the care of your septic system.
Be aware that later changes to your building may require appropriate alterations of your septic
system.
If you have any questions regarding this permit, please contact the Eagle County Environmental
Health Division at (970) 328-8755.
Sincerely,
Janet Kohl
Environmental Health Department
Eagle County Community Development
ENCL:Informational Brochure
Final ISDS Permit
cc: files
ISDS PERMIT # le� %
PERCOLATION TEST
EAGLE COUNTY ENVIRONMENTAL HEATLH
OWNER: bosSow r �us ice'
•PHSYSICAL ADDRESS: 30 Z StfOA.K UiylIt-
LEGAL DESCRIPTION: to I -d -A (, " 5
MAILING ADDRESS: 47�o7 60 3
TYPE OF DWELLING: Y, S , NUMBER OF BEDROOMS: N
TEST HOLES PRE-SOAKED: YES NO 900
SOIL
TIME WATER DEPTH INCHES OF FALL RATE PROFILE
nl
z
f�` 1
7 I vTLI,3/1
Z �,�
-��
z.
a �s
21
3,�
y
a
31
i
3�
I ���
s
2 �s
41
ICI II
v
lb'12-
.
51
15
I s'�z
I �'tv
3/y
61,
'o®
io
6
g
81
1
10
10
TIME TO DROP LAST INCH: {l) PERC RATE: 2-V
MINIMUM LEACH FIELD SIZE: MINIMUM SEPTIC TANK SIZE: LaD /o
COMMENTS: C,�2,t G.._
i� Z�. q z � > '700
ENVIRONMENTAL HEALTH SPECIALIST DATE
� U( v61h�f�s
ISDS Permit # 1 q ) S 'C
Date G /-50 l !
ISDS Final Inspection
Completeness Form
Tank is 1zSy gal. Tank Material
Tank is located 19 ft and ]�0 degrees from C
(permanent landmark)
Tank is located
ft. and degrees
from ^'���/(' p
(permanent landmark//l^�7)JJ" ' ) `
*"ki "-I -
- n � ;(� -}o
� ,
Tank set level.
✓ Tank lids within
8" of finished grade.
VZ
Size of field
Ila'��$ ft' �� units
lineal ft.
Technology _
1-� I-D t o
At OYU
✓ Cleanout is installed
in between tank
and house(+ 1/100ft).
There is a 'IT"
that goes down 14 inches in the inlet and
outlet of the
tank.
Inlet and outlet is sealed with tar tape, rubber gasket etc.
vZ Tank has two compartments with the larger compartment closest to the
house.
Measure distance and relative direction to field.
__ZDepth of field —q ft.
►v / �� Soil interface raked.
---"Inspection portals at the end of each trench.
Proper distance to setbacks. SAY 5 5
Chambers properly installed as per manufacturers specifications.
(Chambers latched, end plates properly installed, rocks removed from
trenches, etc.)
Type of pipe used for building sewer line -
Other
Inspection meets requirements.
Copy form to installer's file if recommendations for improvement were
suggested.
ACTION TAKEN:
Setbacks
Well Potable House Property Lake Dry Tank Drain
Water Lines line Stream Gulch
Field
100
25
20
10
50
25
10
10
Tank
50
10
5
10
50
10
*
10
30-2
Ic GIOM A4m 014.71 !.CXrP41liETOL, SEE!-qj*2L--C-!*
CALCULATED BY
DATE
CHECKED
SCALE
DATE
1915-99 Tax #2111-064-05-023
Lot #8, Filing 5 BOSSOW
JOB NAME _ Bertroch Subdivision
302 Strohm Circle, Gypsum
06 LOCATION
BILL TO
DATE ST TED Q
1q, r
DATE. COMPLETED
--:[DATE
BILLED
11<r 0=f� t c(�
8
JOB COST SUMMARY
TOTAL SELLING PRICE
TOTAL MATERIAL
TOTAL LABOR
INSURANCE
SALES TAX
MISC. COSTS
TOTAL JOB COST
GROSS PROFIT
LESS OVERHEAD COSTS
% OF SELLING PRICE
NET PROFIT
JOB FOLDER Product 277
L
krJ cP 1 q t S -f Ri ossozJ
lohlaq 43
� z
JOB FOLDER
(q 15-qq q
605�,-6 L I
302- 5- brbk C rlf
Iof 9 f�e &COclam_
2 l 1 1_ U-oo 01� C) 23
b
+r-e z,
[Did''l _
Printed In U.SA
INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway • Eagle, CO 81631
Telephone: (970) 328-8755
COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 183 6-98 BP NO. TOG
OWNER: RUSTY BOSSOW PHONE: 970-524-9757
MAILING ADDRESS: P.O. BOX 4202, GYPSUM, CO 81637
APPLICANT: SAME PHONE:
SYSTEM LOCATION: 302 STROHM CIRCLE. GYPSUM, CO TAX PARCEL NO. 2111-064-05-023
LICENSED INSTALLER: BOSSOW EXCAVATING, REX BOSSOW LICENSE NO. 23-98 PHONE: 970-524-9888
DESIGN ENGINEER: LKP ENGINEERING, LUIZA PETROVSKA PHONE NO. 970-926-9088
INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: CLEAR STREAM SYSTEM
1000 GALLON 2-COMPARTMENT SEPTIC TANK, 1000 GALLON AEROBIC UNIT. 1000 GALLON PUMP TANK, 563 SQUARE FEET OF ABSORP-
TION AREA 282 FEET OF DRIP LINE IRRIGATION VIA 141 EMITTERS.
SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN DATED 12/8/98. ENGINEER TO FIELD VERIFY FOUR FOOT SEPARATION TO
TO BEDROCK. ENGINEER IS RESPONSIBLE FOR FINAL INSPECTION. MAINTENANCE AGREEMENT MUST BE OBTAINED PRIOR TO SEPTIC
SYSTEM FINAL APPROVAL. BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL SEPTIC SYSTEM HAS RECEIVED FINAL
INSPECTION AND APPROVAL.
ENVIRONMENTAL HEALTH APPROVAL: /"V , DATE: DECEMBER 31, 1999
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS,
ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING
REQUIREMENTS, CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO
BE LICENSED.
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL
THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: SQUARE FEET (VIA )
INSTALLED TANK: GALLONS IS LOCATED _ DEGREES AND FEET FROM
COMMENTS:
ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN
WORK IS COMPLETED.
ENVIRONMENTAL HEALTH APPROVAL DATE:
(Site Plan MUST be attached)
,Q
ISDS Permit # 1(06
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE — EAGLE COUNTY
P. 0. BOX 179
EAGLE, CO 81631
328-8755/927-3823 (El Jebel)
**************************************************************************
* PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE-$200.00
* *
* MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER"
**************************************************************************
PROPERTY OWNER:
MAILING ADDRESS:
✓� � 2i 4-�/
PHONE: _( qf%O ) - 97S7
APPLICANT/ CONTACT PERSON-
, L-w ffo5-501,J
PHONE: 676
) S"a q-- jM
MAILING ADDRESS: a Z3Q
qd0a 6y a S zem Ga
fr/ b 3'7
LICENSED ISDS CONTRACTOR:
i-Xnxvoq-e o v,
PHONE • (q%O
) S�)e/
COMPANY / DBA :
ADDRESS: C? -61—Y
4,169
*�kic9cie�ic�cslc�k*4e�rie�c*�k�kic�k**ole*irk*icic�Y4e�kie�t�k�k*4c�c**9c�c4ck�k�k�k�k�k�k�k�k*ic*icleic�lr9r�k9c*�k*�k**sir*�k*lek�c
PERMIT APPLICATION IS FOR:
New Installation ( )
Alteration
( j Repair
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Building Permit # (if known)
'Stro-ki-I C:rt. fe.
Legal Description: Subdivision: ��✓�"P'0Ck Filing:5Block: Lot No. 16
Tax Parcel Number: - - -� Lot size:_
Street Address: ,-11)01 ;
***************************************************************************
BUILDING TYPE: (Check applicable category)
(, Residential/Single Family
( ) Residential/Multi-Family*
( ) Commercial/Industrial*
TYPE OF WATER SUPPLY: (Check applicable category)
( ) Well ( ) Spring ( ) Surface._,
(k) Public Name of Supplier:
*These systems
SIGNATURE: S
************
Number of
Number of
Type
Bedrooms 3
Bedrooms
0
ire design by a Registered —Professional Engineer
eC Date:
********************************************************
TO BE COMPLETED BY THE COUNTY
AMOUNT PAID: �0'7 RECEIPT #: DATE:
CHECK #: CASHIER:
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970)328-8755
Fax: (970)328-8788
Pro'ectAddress Parcel No.
000302 STROHM CIR GYPSUM AREA, CO 211106405023
owner Intormatlon Address
RUSTY BOSSOW Phone: 970-524-9757
Cell:
Engineer(s) Phone
LKP ENGINEERING 827-9088
Contractor(s) License Number Phone Primary Contractor
Inspections:
For Inspections call: (970) 328-8755
Inspection IVR
Permitted Construction / Details:
Clearstream system, 1000 gallon 2 compartment septic tank, 1000 gallon aerobic unit, 1000 gallon pump
tank, 563 sq' of absorption area via 282 ' of drip line irigation with 141 emitters.
CONDITIONS:
Office Copy
1. THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT
COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S. 25-10-101, et seq., AS AMENDED
3. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND
BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN
BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL
SYSTEM TO BE LICENSED
Andrew Jessen April 26, 2011
Issued by: Environmental Health Department, Eagle County, CO . Date
i— LW' i�Ju .L4. ac ZIru-7LD_=IUO7 L-Nr GINUlIN=KiNU, INN HAUL b1
December 28, 1998
Ms. Heather Savallo%
Eagle .County Environmental Rtalth Division
P.O. Box 179
Eagle, CO 8 163 1
Via Fax: 328-7185
RE; Amendment to the Septic System Design - Rusty BONOW Residence
Lot 8, Bertroch Subdivision, Filing No. 5
Eagle County, Colorado
Project No. 98175
Dear Heather:
At your request, and as per the Eagle County regulations for and individual septic system design,
on December 22, 1998, we inspected an $-foot profile hole. The hole was dug west of the proposed
leachfield. The soil profile consisted of one faQt of topsoil ever four feet of brown, sandy -,gravelly silt, over
3.5 feet of weathered to firm bedrock. Ground water was not encountered. The proposed Clearstream
System for this site is very shallow (8-inches). The minimum separation of four feet between the bottom of
the system and the top of the bedrock will be maintained.
If you have any questions please do not hesitate to gall.
Sincerely,
LKl' Engineering
,J
Luiza Petrovska,
President
cc: Mr. Rusty Bossow
c.10FrIL EIw Pwmnw}DOC S%9175SD.WPD
P.O. Box 2837, Edwards, Colorado $1632 • (970) 926.9088 Tel ® (970) 926-9089 fax
1836-98 Tax #2111-064-0S-ULJ
Lot #8, Filing 5 BOSSOW
JOB- NAME Bertroch Subdivision
302 Strohm Circle, Gypsum
JOB NO, JO (1
LOCATION
BILL TO
DATE STARTEDq p
zg�d—1 0
DATE- COMPLETED
DATE FULLED
171
2 Z% gm ,Ce,---d 50iis
or- h) ;s.suQ iw L!d des;
k oa oh:� uh oov
f �l� � fi'� aye
= 5�3ft 2-9z�pf, aF �fiy: lr.�c,e_ 14 a,
1 q / e ' l4rs • mi n k4l a1-u-
/na, 44,1`h 4z > f
JOB COST SUMMARY
TOTAL SELLING PRICE
TOTAL MATERIAL
TOTAL LABOR
INSURANCE
SALES TAX
MISC. COSTS
TOTAL JOB COST
GROSS PROFIT
LESS OVERHEAD COSTS
% OF SELLING PRICE
NET PROFIT
JOB FOLDER Product 277
JOB FOLDER
Printed in U.S.A.
AIR DROP
LINE
1' PVC PIPE TO SPRINKLERS NOTES
SIGNAL WIRE FROM
LARM FLOAT TO
ONTROL PANEL
SURGE CONTROL
1. WASTEWATER TREATMENT
INLET
WEIR INSIDE
PLANT CONSTRUCTED OF
PVC
PVC TEE _
FIBERGLASS REINFORCED
PLASTIC OR CONCRETE.
2. PRIMARY TREATMENT UNIT
AND PUMP TANK MAY BE
OUTLET ----a
O
POLYETHLENE, FIBERGLASS OR
CONCRETE AS SPECIFIED BY
BAFFLE
LOCAL DEALERS.
..
3/4 REMOVABLE
3, FOR BELOW NORMAL
FLEXIBLE HOSE TO
GRADE INSTALLATION
4'SCH. 40 PVC EXTENSION MUST BE
DIFFUSER
DISCHARGE LINE USED.(MAXIMUM DEPTH 187
4. AIR COMPRESSOR MAY BE
3/4" PVC
INSTALLED AT REMOTE
AIR LINE
LOCATION UP TO 100' AWAY.
PLANAERATOR
- EXTENSION RISER POLY ITEM #P1947
(NOTE 4)
CCESS COVER GREEN POLY ITEM #P1915
AIR DROP
LINE CONDUIT
INVERT LEVEL SIGNAL WIRE
TO CONTROL PANEL
(1) TAMPER -RESISTANT SCREW
FINISHED GRADEACCESS
COVER
C UNION
TO EFFLUENT DISPOSAL -
METHOD (I.E. DRIP OR
INLET BAFFLE
15'
SURFACE IRRIGATION)
CLEARSTREAM CHLORINATOR
RM
MODEL P-120
OUTLET
FLOAT
BALL VALVE TO CONTROL BY-PASS
BAFFLE
EFFLUENT TO STIR SETTLED SOLIDS
CLEARSTREAM ALARM FLOA t
CLARIFIER CHAMBER
SWITCH ITEM 56
131
CLEARSTREAM PUMP FLOAT
AIR LINE
AIR LINE
SWITCH ITEM #��_
SUPPORT
CLEARSTREAM 1 /2 HP
-
115VAC 20 GPM PUMP
- - - - -
--
- -- - - —
-
-- — - -
- -
-- MODEL-P-2O - _ - --
PRIMARY TREATMENT DEVICE
(NOTE 2)
AERATION
"AMBER
PNoE
CLEARSTREAM �
2)
W. a aonoIx1K
WASTEWATER SYSTEMS. INC.
bM"rlbw •eMrw �..� b 0WWk%*" .w b ow Powell of
- AERATION
TANK - -
P.O. Box 9337 Beoumont, Texas 77709 -
oifb•'" "O"'•O'� �"'"" V" """ Ani11i° oft •
�.:.
SECTION
409-755-15W FAX 409-755-6500
�wb�cgoq bddgtlw� iMnl�wioa. Y •
hyd%ww,—""z
_
TYPICAL INSTALLATION
� �„�owt ,�
PLAN,- SECTION & DETAILS
Omubm WvbweWr,,.,.,�,�. ,.�,b.`•�.w,e d
ft- aeluM ryr d r� lAY
_
_
wA r Y» �dwM• reo.p d a..w..• r•w..wr s�r.�w
ba Qcww*wn L ba-1M7
DRAWN:
I CHKD: I
DATE:
I M.
I M. DATE:
I DRAWING NUMBER:
f
r
i
NoTi^s:
1. The building sewer line from the house to the septic tank shall have a maximum shpe of 114 inch per foot. Bends in the building
sewer shall be limited to 45 degrees. `
2. - Tile septic tank shall be Installed level. The tank shall have removable covers or minholes to within 8 inches of the finished grade,
for inspection and cleaning.
k
J. Follow the manufacturers recommendations forinstallation of the system. The drip line should be installed at a depth of 8 inches. The
drip line will followthe ground contours. Each drip line shall be level. -
4. Avoid vehicle traffic over the system.
I
5. All installations shall meet the rules and regulations of the Town of Gypsum and tie Eagle County Environmental Health Division,
t
Chapter 4, Individual Sewage Disposal Systems.
6. The Septic System Installation shall be inspected by the Design Engineer and the Ea1/e ounty Environmental Health Officer prior to
backfilling.
I