HomeMy WebLinkAbout1002 Bruce Creek Rd - 210925100004INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway • Eagle, CO 81631
Telephone: (970) 328-8755
COPY OF PERMIT MUST BE POSTED A TINSTALLA TION SITE. PERMIT NO. 1885-99 BP NO. 12640
OWNER: TODD AND PEGGY RUCKER PHONE: 970-328-7330
MAILING ADDRESS: P.O. BOX 1031, AVON, CO 81620
APPLICANT: SAME PHONE:
SYSTEM LOCATION: 1002 BRUCE CREEK RD., EAGLE, CO TAX PARCEL NO. 2109-251-00-004
LICENSED INSTALLER: CORKY'S GAS, JAMES FITZSIMMONS LICENSE NO. 7/99 PHONE: 970-524-9722
DESIGN ENGINEER: PHONE NO.
INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 3 BEDROOM RESIDENCE
1000 GALLON SEPTIC TANK 844 SQUARE FEET OF TRENCH ABSORPTION AREA VIA 27 CHAMBERED UNITS
SPECIAL REQUIREMENTS: INSTALL IN SERIAL DISTRIBUTION IN TRENCHES WITH A CLEANOUT BETWEEN THE TANK AND THE HOUSE AND INSPEC-
TION PORTALS IN EACH TRENCH. RAKE ALL TRENCH SURFACES TO PREVENT SMEARING OF SOILS. AND DO NOT INSTALL IN WET WEATHER. BE
SURE TO MAINTAIN ALL SETBACK REQUIREMENTS. CALL EAGLE COUNTY ENVIRONMENTAL HEALTH FOR FINAL INSPECTION PRIOR TO BACK
FILLING ANY PORTION OF THE INSTALLATION, OR WITH ANY QUESTIONS REGARDING INSTALLATION. BUILDING TEMPORARY CERTIFICATE OF
OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS RECEIVED FINAL APPROVAL.
ENVIRONMENTAL HEALTH APPROVAL: DATE: JULY 15, 1999
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS,
ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING
REQUIREMENTS, CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO
BE LICENSED.
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM
IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: 844 SQUAREFEET(VIA 27 INFILTRATOR TTNTTS
INSTALLED CONCRETE SFPTTC TANK: 1250 GALLONS IS LOCATED 290 DEGREES AND 1 9 ' R" FEET FROM THE CLE IiTC)11T
COMMENTS: FINAL INSPECTION DONE BY LAU A FAWCETT ON OCTORFR 21, IAAA_ HOMEOWNER WAS TNSTRUCTF
TO RAKE ALL TRENCH SIDEWALLS DUE TO THE SMEARING OF CLAY SOTTS
ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS
COMPLETED.
ENVIRONMENTALHEALTH APPROVAL(_/I_(_[�tAJZ,� DATE: OCTOBER 25, 1999
Incomplete Applications Will NOT Be Accepted
(Site Plan MUST be attached)
ISDS Permit # _
Building Permit
lg0�j
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY
P. 0. BOX 179
EAGLE, CO 81631
328-8755/927-3823 (El Jebel)
* PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00
*
* MAKE ALL.REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER"
**************************************************************************
PROPERTY OWNER: 1(J
MAILING ADDRESS: 8evi C4 PHONE
APPLICANT/CONTACT PERSON: PHONE: 57�'
LICENSED SYSTEMS CONTRACTOa�► �WI UVI h%i PHONE :�`f'�,ZZ
COMPANY/DBA : C&yl S C-) a> ADDRESS : C� � 64
PERMIT APPLICATION IS FOR: (1--f NEW INSTALLATION ( ) ALTERATION•( ) REPAIR
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Legal Description
Tax Parcel Number
Physical Address: I MZ &tf- Crne-�M , k- �-�
BUILDING TYPE: (Check applicable category)
(✓�Residential/Single Family Number of Bedrooms
( ) Residential/Multi-Family* Number of Bedrooms
_ ( ) Commercial/Industrial* Type
TYPE OF WATER SUPPLY: (Check applicable category)
(L-r- Well ( ) Spring ( ) Surface
( ) Public Name of Supplier:
*These sys ms require d sign by a Registered Professional Engineer
SIGNATUR : Date:
AMOUNT PAID: 3S RECEIPT #: lI3f DATE:
CHECK #: 1. I CASHIER:
Community Development Department
(970)328-8730
FAX (970) 328-7185
TDD (970) 328-8797
Email: eccmdeva@vail.net
http: //www.eagle-county.com
EAGLE COUNTY, COLORADO
October 25, 1999
Todd and Peggy Rucker
P.O. Box 1031
Avon, CO 81620
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
RE: Final of ISDS Permit #1885-98, Tax Parcel #2109-251-00-004. Property location: 1002
Bruce Creek Rd., Eagle, CO.
Dear Mr. & Mrs. Rucker:
This letter is to inform you that the above referenced ISDS Permit has been inspected and
finalized. Enclosed is a copy to retain for your records. This permit does not indicate
compliance with any other Eagle County requirements. Also enclosed is a brochure regarding
the care of your septic system.
Be aware that later chp s to your building may require appropriate alterations �r septic
system.
If you have ar- ons regarding this permit, please contact the Eagle CouW,. environmental
Health Division at (970) 328-8755.
Sincerely,
Janet Kohl
Environmental Health Department
Eagle County Community Development
ENCL:Informational Brochure
Final ISDS Permit
cc: files
ISDS PERMIT # 199
PERCOLATION TEST
EAGLE COUNTY ENVIRONMENTAL HEATLH
A1L9►1 P Amim
•PHSYSICAL ADDRESS: Z ,rd
LEGAL DESCRIPTION:
MAILING ADDRESS: O , ox / 031 d vc1i , Gcv E-1 bw
TYPE OF DWELLING: NUMBER OF BEDROOMS: 3
TEST HOLES PRE-SOAKED: YES ✓ NO
SOIL
TIME WATER DEPTH INCHES OF FALL RATE PROFILE
(y
31q
r 0_'04
3s
Vlig
31
o
I
��Z
�'��f
-
E
14
�
217
yU
10
Vs',
ias/g
13
31q
8
4'
1/4
i
tVIq
s%
►
'%
s
5�
5 �
1514
��'z
3/ �
��'�
► . 3ao
6'
00
1
13
3��
��z
S
o
'
Y�
%�
I;1S
\
t o
Z
/q
IN
-�v
1
o
'
I -
I
)/� I
Q z
►z
!a
10'
76ivLL,
k-
TIME TO DROP LAST INCH: PERC RATE& I � � tj -
MINIMUM LEACH FIELD SIZE: ''y MINIMUM SEPTIC TANK SIZE: oo (0a� 3�h c%
COMMENTS:
ENVIRONMENTAL HEALTH SPECIALISTllA I H
ISDS Permit
ISDS Final InaRection
CgMleteness Form
Tank is gal. Tank Material QX�VUl•0
Tank is located ft. and degrees from
(pezeanm[ landmark)
� u
Tank is located ft. and degrees from C IL&::�
(permaumt landmark)
Tank set level. Tank lids within 6" of finished grade.
Size of field 7 tz � � units lineal ft.
/Technology
V Cleanout is installed in between tank and house(+ 1/100ft).
There is a "T" that goes down 14 inches in the inlet and
outlet of the tank:
Iinlet.and outlet is sealed with tar,,tape,rubber gasket etc.
VTr k has two compartments with the.- 3;arger..,GQm,,partment closest to the ,,,,-
house.
.
'•Meaeure: distance and relative direr --ion, to:,fa.eld;
",,'.,Depth- of of field. �Z ft .
Soil interface raked.
Inspection portals at the.end of each trench..
Proper distance to setbacks.
Chambers properly installed as per manufacturers specifications.
(Chambers latched, end plates properly installed, rocks 'removed from
trenches, etc.)
Type of pipe used for building sewer line SDP leach field SD,CS 7
other
inspection meets reguirements.
Copy form to installer's file if recommendations for improvement were
suggested.
ACTION TAKEN:
Setbacks
Well Potable House Property Lake Dry Tank Drain
Water Lines line Stream Gulch
Field 100 25 20 10 50 25 10 10
Tilk 50 10 5 10 50 10 * 10
z
00
co
00
cn
OD
1885-99 Tax# 2109-251-00-004
Parcel #4, RUCKER
JOB NAME Bruce Creek Ranch
1002 Bruce Creek Rd., Eagle
JOB NO. IV- Ma ( Vb
JOB LOCATION
BILL TO
DAT STARTED
6 ��h y
DATE COMPLETED
DATE BILLED
AdF
z flf& w-44-
u P Lf z a
7' //S- wellizi �a�.ZL
nn:�&
In UAL
1
)WIW-alb
fD (
Z"td-Z� A;L
61
JOB COST SUMMARY
=
TOTAL SELLING PRICE
TOTAL MATERIAL
TOTAL LABOR
INSURANCE
SALES TAX
MISC. COSTS
TOTAL JOB COST
GROSS PROFIT
LESS OVERHEAD COSTS
% OF SELLING PRICE
NET PROFIT
JOB FOLDER Product 277
JOB FOLDER
q
In�&LA-' -cx
�2gDct- 251-00 �' t
�&
to() 2 V..r-A-_�
Printed In U.S.A.