Loading...
HomeMy WebLinkAbout766 Frost Creek Dr - 210925302002Work Classification:New CO AddressOwner Information Permit Status:Active Project Address 210925302002 Permit Type:OWTS Permit Permit NO.OWTS-4-18-19022 Expires:11/29/2018Issue Date:8/1/2018 Parcel No. 766 FROST CREEK DR Private Wastewater System Environmental Health Department P.O.Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970)328-8755 Fax: (970)328-8788 Phone: Cell:(970)331-1150 Inspection For Inspections call:(970)328-8755 Inspections: IVR OWTS Final Inspection 095 PhoneEngineer(s) (303)565-4927JVA, Inc Contractor(s)Phone Primary ContractorLicense Number BEAUMONT EXCAVATING (970)390-9393 Yes24-18 Louis Rinn Permitted Construction /Details: Installation of the OWTS exactly as depicted in the JVA, Inc.design packet stamped, signed and dated April 20,2018 by Kevin A.Tone, PE.The OWTS is designed to serve a 5 bedroom residence. The system consists of a Valley Precast 1,500 gallon, single compartment tank (Model 1500T-1CP)with effluent screen and alarm placed on the outlet, followed by a 2,000 gallon Valley Precast 3 compartment recirculating/dose tank which will send wastewater to two, Advantex AX20 pods for nitrification using an Orenco PF 300512 pump.Nitrified effluent flows to the splitter valve (mode 3B)for recirculation to the 1,500 gallon tank for denitrification, then is dosed using an Orenco PF751012 to 1,250 square feet of soil treatment area (prior to adjusting 30%for using chambers and 20%for pressure dosing)consisting of 4 trenches of Infiltrator Quick 4 Plus standard chambers, each trench having 15 Infiltrator chambers as shown on the design drawing for a total of60 chambers.Note the elevation at which the bottom of the infiltrative surface is located, necessitating final grade cover as specified on the plans.The contractor must verify that the electrical components are covered under the electrical permit associated with the Orenco Vericom control panel and pump connections. Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior to backfilling any component of the OWTS.The design engineer is responsible for conducting all inspections necessary to certify the installation and assure functionality of the system. System certification, along with photos and a record drawing is required to be submitted to, and approved by, Eagle County Environmental Health prior to the use of the system or occupancy of the dwelling. Issued by:Environmental Health Department, Eagle County, CO September 25, 2018 Date Customer Copy Ray Merry CONDITIONS: 1.THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT 2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S.25-10-101,et seq., AS AMENDED 3.THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS.CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4.CHAPTER IV, SECTION 4.03.29REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED PAID ON 04/26/2018 $800 - CHK# 73131 4/26/201873131$800 8-18-19022 Beaumont Excavation - 970-390-9393 24-18178 Alpine Ranch Rd-Gypsum -bexinc@mail.com January 2, 2020 Mr. Louis Rinn 178 Alpine Ranch Rd Gypsum, CO 81637 louis@rinnbuilders.com RE: Final approval of the: Septic System Installation, OWTS-4-18-19022 Property location: 766 Frost Creek Dr, Eagle County Parcel No. 210925302002 Mr. Rinn, This letter is to inform you that the above-referenced permit has been inspected and finalized. The Onsite Wastewater Treatment System (OWTS) was designed and installed to serve the five bedroom residence on the above property. The OWTS installed is considered a higher level treatment system by Eagle County Public Health Agency’s OWTS Regulations and must be operated and maintained in accordance with applicable regulations, as well as the Frost Creek PUD and the manufacturer’s instructions. Additional information about the maintenance your septic system needs can be accessed through our website links, provided on the Environmental Health Department’s septic system resource page. Be aware that changes in the use of your property or alterations of your building may require commensurate changes to, or relocation of, your septic system. Landscape features, trees with tap roots, irrigation systems and parking areas above the soil treatment area can cause premature system failure. It is equally important that you notice and immediately repair dripping faucets and hissing toilets as this will certainly cause the system to fail. If you have any questions regarding this information, please contact us at (970) 328 -8755 and reference the OWTS septic permit number. Best Regards, Claire Lewandowski, REHS Environmental Health Specialist III Attachments: Certification Letter and Design – Septic System Flyer – Final Letter PUBLIC HEALTH & ENVIRONMENT (970) 328-8755 FAX: (970) 328-8788 environment@eaglecounty.us December 30, 2019 Mr. Ray Merry, Director of Environmental Health Eagle County Environmental Health 500 Broadway Street Eagle, CO 81631 RE: Onsite Wastewater Treatment System Final Certification – 766 Frost Creek Dr, Lot 65 Dear Ray: The Onsite Wastewater Treatment System (OWTS) covered under Eagle County Permit No. OWTS-4-18-19022 was installed by Beaumont Excavating (License Number 24-18) for 766 Frost Creek Drive, and is ready for final certification from Eagle County Environmental Health. The engineer of record for this system is Kevin Tone with JVA, Inc (JVA). The final record drawings from JVA, and construction photographs are provided as attachments. As part of the final approval process JVA ensured that start-up was completed by the manufacturer’s representative (Jerry at Valley Precast) and that a communication line was connected to the control panel. The system is connected and can be monitored remotely as required in the PUD. Please proceed with the closeout process for this OWTS permit. Sincerely, JVA, INCORPORATED By: ________________________ Kevin Tone, P.E., LEED AP President Enclosure: Attachment A – Record Drawings Attachment B – Construction Photographs CC: Simon Farrell, JVA James Cochran, JVA ATTACHMENT A – RECORD DRAWINGS FROST CREEKLOT 65 ONSITE WASTEWATER TREATMENT SYSTEMEAGLE, COLORADOPERMIT SETAPRIL 2018Set No._______JVA, Inc.1512 Larimer Street, Suite 710www.jvajva.comDenver, CO 80202303.444.1951Boulder ● Fort Collins ● Winter ParkGlenwood Springs ● Denver LEGEND, NOTES AND ABBREVIATIONSG0.1REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY:DRAWN BY:CHECKED BY:JOB #:DATE:© JVA, INC.FROST CREEK LOT 65 OWTS EAGLE, COLORADOSHEET NO.2476.8cAPRIL 2018JVA, Inc.1319 Spruce Streetwww.jvajva.comBoulder, CO 80302303.444.1951Boulder ● Fort Collins ● Winter ParkGlenwood Springs ● DenverKATJCDJRCCONFORMED TO CONSTRUCTION RECORD SITE PLANC1.0 REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY: DRAWN BY: CHECKED BY: JOB #: DATE: © JVA, INC.FROST CREEKLOT 65 OWTSEAGLE, COLORADOSHEET NO. 2476.8c APRIL 2018 JVA, Inc.1319 Spruce Street www.jvajva.com Boulder, CO 80302 303.444.1951 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver KAT JCD JRC CONFORMED TO CONSTRUCTION RECORD REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY: DRAWN BY: CHECKED BY: JOB #: DATE: © JVA, INC.FROST CREEKLOT 65 OWTSEAGLE, COLORADOSHEET NO. 2476.8c APRIL 2018 JVA, Inc.1319 Spruce Street www.jvajva.com Boulder, CO 80302 303.444.1951 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver KAT JCD JRC TREATMENT SYSTEMP1.0CONFORMED TO CONSTRUCTION RECORD REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY: DRAWN BY: CHECKED BY: JOB #: DATE: © JVA, INC.FROST CREEKLOT 65 OWTSEAGLE, COLORADOSHEET NO. 2476.8c APRIL 2018 JVA, Inc.1319 Spruce Street www.jvajva.com Boulder, CO 80302 303.444.1951 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver KAT JCD JRC SOIL TREATMENT AREAP1.1CONFORMED TO CONSTRUCTION RECORD ATTACHMENT B – CONSTRUCTION PHOTOGRAPHS