HomeMy WebLinkAbout1001 Piney - 194512400007Work Classification:New
PO BOX 1672
EAGLE CO 81631-1672
AddressOwner Information
Permit Status:Active
Project Address
194512400007
Permit Type:OWTS Permit
Permit NO.OWTS-4-18-19004
Expires:12/5/2018Issue Date:8/7/2018
Parcel No.
SECTION 12 TOWNSHIP,4 RANGE, 81 WEST VAIL, CO
Private Wastewater
System
Environmental Health
Department
P.O.Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970)328-8755
Fax: (970)328-8788
Phone:(570)236-5348
Cell:(570)236-5348
Inspection
For Inspections call:(970)328-8755
Inspections:
IVR
OWTS Final Inspection 095
PhoneEngineer(s)
(970)945-7988H-P Kumar
Contractor(s)Phone Primary ContractorLicense Number
WY Construction (970)328-6641 Yes34-18
WINDSWEST INC
Permitted Construction /Details:
Install OWTS exactly as depicted in the H-P Kumar design report dated July25,2018, stamped and signed
by David A.Young on July 26,2018.This design replaces the previous design dated April23 ,2018 by
James A.Parker, P.E.The system is designed to serve a 4 bedroom cabin.
The system consists of a Valley Precast 1,250 gallon, two compartment septic tank (item #1250T-2CP)
equipped with an effluent screen in the outlet tee and750 square feet of soil treatment area (prior to
taking the 30%adjustment for using chambers)via the installation of 44 Infiltrator Quick 4 Plus Standard
chambers arranged in two shallow trenches with22 chambers per trench.Each trench will receive equal
amounts of effluent from a four hole Tuf -Tite distribution box with speed levelers.
NOTE:Inspection portals must be placed at both the front and distal ends of each trench and the
maximum trench depth must remain less than 2' to meet vertical separation requirements to bedrock.
The well must be installed at least100' from the soil treatment area and shown on the record drawing as
meeting this horizontal setback.
Contact Eagle County Environmental Health and the design engineer at least48 hours of requesting
inspections.All inspections necessary to certify proper installation must be performed by the design
engineer.System certification along with photos and a record drawing are required to be submitted to,
and approved by, Eagle County Environmental Health prior to the use of the system and occupancy of the
cabin.
Issued by:Environmental Health Department, Eagle County, CO
August 07, 2018
Date
Customer Copy
Giovanna Harkay
CONDITIONS:
1.THIS PERMIT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT
COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN C.R.S.25-10-101,et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS.CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND
BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN
BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.CHAPTER IV, SECTION 4.03.29REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL
SYSTEM TO BE LICENSED
34-18
October, 11th, 2018
Mr. Bruce Hagedorn
Wind West, Inc.
Po Box 1672
Eagle, CO. 81631
RE: Final approval of the: Septic System Installation, OWTS-4-18-19004 Property location: Cabin
at Piney Ridge, Eagle County Area.
Mr. Hagedorn:
This letter is to inform you that the above-referenced, OWTS-4-18-19004 permit, has been
inspected and finalized. This OWTS permit was approved and sized to serve a 4 bedrooms cabin.
Additional information about the maintenance your septic system needs can be accessed
through our website links, provided on the Environmental Health Department’s septic system
resource page.
Be aware that changes in the use of your property or alterations of your building may require
commensurate changes to, or relocation of, your septic system . Landscape features, trees with
tap roots, irrigation systems and parking areas above the soil treatment area can cause
premature system failure. It is equally important that you notice and immediately repair
dripping faucets and hissing toilets as this will certainly cause the system to fail.
If you have any questions regarding this information, please contact us at (970) 328-8755 and
reference the OWTS septic permit number.
Best Regards,
Giovanna Harkay.
Administrative Fiscal Tech IV
Attachments: Certification Letter and Design – Septic System Flyer – Final Letter
PUBLIC HEALTH & ENVIRONMENT
(970) 328-8755
FAX: (970) 328-8788
Environment@eaglecounty.us
RAYMOND P. MERRY, REHS
Manager
5020 County Road 154
Glenwood Springs, Colorado 81601
Phone: (970) 945-7988
Fax: (970) 945-8454
Email: hpkglenwood@kumarusa.com
Office Locations: Parker, Glenwood Springs, and Silverthorne, Colorado
October 10, 2018
WindsWest, Inc.
Attn: Bruce Hagedorn
P. O. Box 1672
Eagle, Colorado 81631
bruce.r.hagedorn@gmail.com
Project No. 18-7-212
Permit No. OWTS-4-18-19004
Subject: As-Built Evaluation of Onsite Wastewater Treatment System, Proposed Cabin,
Forest Road No. 701, Near Piney Lake, Township 4 South, Range 81 West, Eagle
County, Colorado
Dear Bruce:
A representative of H-P/Kumar observed the installation of the Onsite Wastewater Treatment
System (OWTS) for the proposed seasonal cabin at the subject site as required by the Eagle
County Environmental Health Department. Our observations and recommendations are
presented in this report. The services are supplemental to our agreement for professional
services to WindsWest, Inc. dated March 21, 2018.
H-P/Kumar previously designed the OWTS for the proposed cabin as submitted in a report dated
July 25, 2018, Project No. 18-7-212. The system was designed for four bedrooms. The OWTS
was installed under Eagle County Permit Number OWTS-4-18-19004 by WY Construction.
We performed our As-Built evaluation August 24, 2018. The OWTS components observed
included: sewer line, cleanouts, septic tank, effluent line, distribution box and soil treatment area
(STA) and the locations of these components. The installation and locations of the system
components were verified as shown on Figure 1. Pictures of the OWTS components made
during our site visit are also included with this report. The distance locations to the tank shown
on Figure 1 were made by taping.
The cleanout between the cabin and the septic tank was moved into the crawlspace to prevent
damage from snow off the roof. A C900 pipe was used to sleeve the water line from the cabin
for 25 feet due to encroachment on the setback to the water line. The distance to the water line
was 5 feet. The STA was reconfigured to three trenches of 14, 15 and 15 chambers from the
designed configuration of two trenches of 22 chambers each. The new configuration maintained
the required 44 chambers. The changes to the original design area acceptable.
PROPOSED
HAGEDORN
CABIN
VALLEY PRECAST
1,250 GALLON
TWO CHAMBER
SEPTIC TANK WITH
EFFLUENT FILTER
CLEANOUTS
TUF-TITE
4-HOLE
DISTRIBUTION
BOX
SOIL TREATMENT AREA
CONSISTING OF THREE
ROWS OF 15 INFILTRATOR
QUICK 4 PLUS STANDARD
CHAMBERS IN TWO ROWS
AND 14 CHAMBERS IN ONE
ROW
PROPOSED WATER LINE
47'
20' 8"
5'
WATER LINE SLEEVED
IN C900 PIPE
PROFILE
PIT 2
PROFILE
PIT 1
OWTS AS-BUILT PHOTOGRAPH LOG
PROPOSED HAGEDORN CABIN
FOREST ROAD NO. 701, NEAR PINEY LAKE
TOWNSHIP 4 SOUTH, RANGE 81 WEST
EAGLE COUNTY, COLORADO
Project No. 18-7-212
Photograph 1: Sewer line
exiting cabin.
Photograph 2: Two chamber,
1,250 gallon Valley Precast
septic tank
OWTS AS-BUILT PHOTOGRAPH LOG
PROPOSED HAGEDORN CABIN
FOREST ROAD NO. 701, NEAR PINEY LAKE
TOWNSHIP 4 SOUTH, RANGE 81 WEST
EAGLE COUNTY, COLORADO
Project No. 18-7-212
Photograph 3: Septic tank inlet
tee
Photograph 4: Septic tank
outlet tee with effluent filter
OWTS AS-BUILT PHOTOGRAPH LOG
PROPOSED HAGEDORN CABIN
FOREST ROAD NO. 701, NEAR PINEY LAKE
TOWNSHIP 4 SOUTH, RANGE 81 WEST
EAGLE COUNTY, COLORADO
Project No. 18-7-212
Photograph 5: Effluent line and
cleanout going toward soil
treatment area
Photograph 6: Tuf-Tite 4-hole
distribution box with speed level
installed
OWTS AS-BUILT PHOTOGRAPH LOG
PROPOSED HAGEDORN CABIN
FOREST ROAD NO. 701, NEAR PINEY LAKE
TOWNSHIP 4 SOUTH, RANGE 81 WEST
EAGLE COUNTY, COLORADO
Project No. 18-7-212
Photograph 7: Typical trench
and Infiltrator Quick 4 Plus
Standard chambers (Inspection
ports yet to be installed)
Photograph 8: Soil treatment
area (Inspection ports and
effluent line yet to be installed)