HomeMy WebLinkAbout1001 Ten Peaks Mesa Rd - 239104102001Inspection Result Eagle County, Colorado P.O. Box 179 500 Broadway Eagle, CO Phone: (970) 328-8730 Fax: (970) 328-7185 IVR Phone: 1-866-701-3307 Inspection Number: INSP-504142-2020 Permit Number: OWTS-017150-2019 Inspection Date: 12/01/2020 Inspector: Lewandowski, Claire Permit Type: OWTS Permit Inspection Type: OWTS Final Inspection Work Classification: NewOwner:Tami Kochen Job Address:1001 TEN PEAKS MESA RD IVR Pin Number:188674 EL JEBEL AREA, CO Project:<NONE> Parcel Number:239104102001 Contractor:Phone: (970) 963-3987 / Cell: (970) 987-7284Daly Excavation Inspection Status: Approved Inspection Notes The above-referenced permit has been inspected and finalized. The Onsite Wastewater Treatment System (OWTS) was designed and installed to serve the five-bedroom residence on the above property. Additional information about the maintenance of your septic system needs can be accessed through links on eaglecounty.org provided on the Environmental Health Department’s septic system resource page. Be aware that changes in the use of your property or alterations of your building may require commensurate changes to, or relocation of, your septic system. Landscape features, trees with taproots, irrigation systems, and parking areas above the soil treatment area can cause a premature system failure. It is equally important that you notice and immediately repair dripping faucets and hissing toilets as this will certainly cause the system to fail. If you have any questions regarding this information, please contact us at (970) 328-8755 and reference the OWTS septic permit number. Inspector Comments Added Item: Septic Tank Installed in compliance with approved design. A two compartment 1,500 gallon Roth poly tank was approved to substitute the concrete tank. Added Item: Record Drawing Received, approved. Added Item: Record Photos Received, approved. Added Item: Site and Soil In compliance. Added Item: Final Certification Letter Prepared by design consultant Carla Ostberg. Stamped, signed, and dated November 17, 2020 by Richard H. Petz, PE. Added Item: General Plan Tuesday, December 1, 2020 For more information visit: http://www.eaglecounty.us Page 1 of 2 Installed in conformance with approved plans. Added Item: Soil Treatment Area (STA) Installed in compliance with approved design. Added Item: Identification of Systems Contractor Installed by Eagle County Licensed Contractor Joseph Bamford Daly Excavation. Tuesday, December 1, 2020 For more information visit: http://www.eaglecounty.us Page 2 of 2 November 13, 2020 Project No. C1457 Tami Kochen tkochen@gmail.com Onsite Wastewater Treatment System (OWTS) Installation Observations 1001 Ten Peaks Mesa Road Eagle County, Colorado Permit Number OWTS-017150-2019 Tami, ALL SERVICE septic, LLC observed the installation of the onsite wastewater treatment system (OWTS) on August 22, 2019 for the subject property. Joe Bamford installed the system. The OWTS design is based on 5-bedrooms, although only a 2-bedroom residence is currently developed. An average daily wastewater flow of 600 GPD was used. A 4-inch diameter SDR-35 sewer line with a double-sweep clean out and a minimum 2% grade to the septic tank was installed after our inspection. Additional clean outs were installed at least 100-feet. The system installation included a 1500-gallon, two-compartment ‘Roth’ poly septic tank with an effluent filter on the outlet tee. Orenco® risers bring the manhole lids to grade for access. Effluent gravity flows to a plastic distribution box, which was accessible from grade with risers. Speed levelers were installed to assure equal flow to each trench. The STA consists of four trenches, each with 15 ‘Quick 4’ Infiltrator® chambers for a total of 60 chambers and 720 square feet of infiltrative area. Trenches were separated by 8-feet of undisturbed soil. Inspection ports were installed at the beginning and end of each trench. Ports may be cut to grade and placed in sprinkler boxes for access. The infiltrative area was at least 2-feet below grade and did not exceed 3-feet below grade. The infiltrative area was placed below the topsoil horizon. The OWTS was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. ALL SERVICE septic, LLC should be notified if changes are made to the OWTS in the future. Any additional OWTS construction must be according to the county regulations. LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. The quality of the installation is dependent of the expertise of the installer, soil type, and weather conditions. Please call with questions. Sincerely, ALL SERVICE septic, LLC Reviewed By: Carla Ostberg, MPH, REHS Richard H. Petz, Septic tank installed Effluent filter and risers were installed after inspection 11/17/2020 Distribution box with access from grade angled pipe on inlet pipe installed after inspection trenches Trenches, separated by 8-feet Inspection ports at beginning and end of each trench 832‐R‐13‐002 July 12, 2019 Project No. C1457 Tami Kochen tkochen@gmail.com Subsurface Investigation and Onsite Wastewater Treatment System Design 2-Bedroom Residence (+ 3 future bedrooms) 1001 Ten Peaks Mesa Eagle County, Colorado Tami, ALL SERVICE septic, LLC performed a subsurface investigation and completed an onsite wastewater treatment system (OWTS) design for the subject residence. The 37.93-acre property is located outside of Basalt, in an area where OW TSs are necessary. Legal Description: Subdivision: TEN PEAKS MESA Lot: 1 R649781 MAP 03-17-98 R649782 DEC 03-17-98 R685319 WD 07-15-98 R820047 DEC 01-13-03 Parcel ID: 2391-041-02-001 SITE CONDITIONS The property is currently undeveloped. A 2-bedroom residence is proposed. Future expansion of the house is possible. We have sized the OWTS to accommodate a 5-bedroom residence. The residence will be served potable water from the community water system. The water line runs up the driveway, to the west of the proposed residence. The proposed STA is on a hillside near the bee hive, to the southeast of the residence. The STA slopes to the east at approximately 10%, which is somewhat inconsistent with how the survey has depicted the topography. The proposed area is covered with native grasses and sage. Table 1 describes the minimum required setback of OWTS components to physical features on the property compared to approximate, proposed setback distances. Table 1 OWTS Components and Physical Features Minimum Required Setback Approximate Proposed Setback House to Septic Tank 5’ 20’ Septic Tank to Well 50’ n/a Septic Tank to Water Course 50’ n/a STA to House 20’ 230’ STA to Well 100’ n/a STA to Water Course 50’ n/a Page 2 SUBSURFACE The subsurface was investigated on July 10, 2019 by digging two soil profile test pit excavations (Test Pits). Visual and tactile soil analysis was completed by Carla Ostberg at the time of excavation.1 The materials encountered in the Test Pit #1 consisted of dark brown, clay loam topsoil to 2.0-feet underlain by tan calcareous sandy silt, or sandy clay with low Plasticity Index to a maximum depth explored of 7.0-feet. The soils have a blocky to loose structure shape, a moderate structure grade, and friable to firm consistence. No bedrock or groundwater was encountered. The materials encountered in Test Pit #2 were consistent with materials in Test Pit #1. The Test Pit was excavated to a maximum depth of 7.0-feet. No bedrock or groundwater was encountered. STA sizing is based on Soil Type 2. A long term acceptance rate (LTAR) of 0.6 gallons per square foot, will be used to design the OWTS. Test Pit #1 Backfill from soil Test Pit #1 1 Carla Ostberg holds a Certificate of Attendance and Examination from the CPOW Visual and Tactile Evaluation of Soils Training. Page 3 Test Pit #1 sieved sample Note horizons Page 4 Note moderate structure grade Test Pit #2 and backfill Note slope to east is gradual toward fence line Page 5 View of test pit #1 looking toward Bee Hive DESIGN SPECIFICATIONS Design Calculations: Average Design Flow = 75 GPD x 2 people/bedroom x 3 Bedrooms + 150 GPD (4th and 5th bedrooms) = 600 GPD LTAR = 0.6 GPD/SF 600 GPD / 0.6 GPD/SF x 1.0 (gravity trenches) x 0.7 (chambers) = 700 SF The OWTS design is based on 5-bedrooms, although only a 2-bedroom residence is currently proposed. An average daily wastewater flow of 600 GPD will be used. For the purposes of this OWTS design, Benchmark Elevation at grade 7673’ has been established as 100’. ALL SERVICE septic, LLC should be notified of any discrepancies or problems with grade elevations of proposed components during installation of the OWTS. OWTS Component Minimum Elevation Primary Tank Inlet Invert 98’ (7671’) Distribution Box 92.5’ (7665.5’) Infiltrative Surface 92’ (7665’) A 4-inch diameter SDR-35 sewer line exiting the residence must have a double-sweep clean out and a minimum 2% grade to the septic tank. Additional clean outs should be installed at least 100-feet. The system installation must include a 1500-gallon, two-compartment septic tank with an effluent filter on the outlet tee. Either an Infiltrator® poly septic tank or Valley Precast concrete septic tank may be used. We have provided specifications for both septic tanks. Risers must bring the manhole lids to grade for access. If more than one riser is added to the septic tank, an extension handle must be installed on the effluent filter. Effluent will gravity flow to a distribution box, which must be accessible from grade. Flow equalizers or similar product must be installed to assure equal flow to each trench. The STA will consist of four trenches, each with 15 ‘Quick 4’ Standard Plus Infiltrator® chambers for a total of 60 chambers and 720 square feet of infiltrative area. Trenches must be separated by at least 4-feet (we recommend 6-feet) of undisturbed soil. Inspection ports must be installed at the beginning and end of each trench. Ports may be cut to grade and placed in sprinkler boxes for access. The infiltrative area must be at least 2-feet Page 6 below grade and must not exceed 3-feet below grade. The infiltrative area must be placed below the topsoil horizon. Fill over chambers must be 3-inch minus and be able to support vegetative growth. The component manufacturers are typical of applications used by contractors and engineers in this area. Alternatives may be considered or recommended by contacting our office. Construction must be according to Eagle County On-Site Wastewater Treatment System Regulations, the OWTS Permit provided by Eagle County Environmental Health Department, and this design. INSTALLATION CONTRACTOR ALL SERVICE septic, LLC expects that the installer be experienced and qualified to perform the scope of work outlined in this design. The installer must review this design thoroughly and coordinate with our office in advance of installation. Any additional conditions in this design or county permit must be completed and documented prior to final approval of the OWTS installation. Communication between the installer and this office is expected throughout the installation. INSTALLATION OBSERVATIONS ALL SERVICE septic, LLC must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the installation. In an effort to improve the accuracy of the record drawing, we request that the installer provide a sketch of the installation, including path of the sewer lines, water line installation (if applicable), septic tank location, STA location, and measurements from building corners or another fixed objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design Packet. Photographs of the installation and final cover are also requested to supplement our installation documentation. REVEGETATION REQUIREMENTS An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing characteristics (but without taproots), provides a maximum transpiration rate, and competes well with successional species. No trees or shrubs, or any vegetation requiring regular irritation shall be placed over the area. Until vegetation is reestablished, erosion and sediment control measures shall be implemented and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation cover. OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. The property owner is responsible for maintaining service contracts for manufactured units, alternating STAs, and any other components needing maintenance. Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials should be placed on the backfilled STA. Livestock should not graze on the STA. Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA. Page 7 If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be flushed annually, or as needed. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of freezing. The pump shall have an audible and visual alarm notification in the event of excessively high water conditions and shall be connected to a control breaker separate from the high water alarm breaker and from any other control system circuits. The pump system shall have a switch so the pump can be manually operated. Excavation equipment must not drive in excavation of the STA due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade. Backfill over the STA must be uniform and granular with no material greater than minus 3-inch. LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, ALL SERVICE septic, LLC should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The contractor should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Licensing of Systems Contractors may be required by county regulation. Please call with questions. Sincerely, ALL SERVICE septic, LLC Reviewed By: Carla Ostberg, MPH, REHS 7/23/19 • Has 5-10 times more flow area than other brands, so lasts many times longer between clean- ings, increasing homeowner satisfaction • Installs in min- utes inside new or existing tanks; extendible tee handle for easy removal • Easy to clean by simply hosing off whenever the tank needs pumping • Removes about two-thirds of sus- pended solids, on average, extending drainfield life • Corrosion-proof construction, to ensure long life • Lifetime warranty Residential Biotube® Effluent Filters Applications Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic tanks and have a lifetime warranty. They prevent large solids from leaving the tank, dramatically improving wastewater quality and extending the life of residential drainfields. Standard Features & Benefits • Alarm available, to signal the need for cleaning • Flow modulating discharge orifices available to limit flow rate leaving tank, mitigat- ing surges and increasing retention time • Custom and commercial sizes available Effluent from the relatively clear zone of the septic tank, between the scum and sludge layers, horizontally enters the Biotube Effluent Filter. Effluent then enters the annular space between the housing and the Biotubes, utilizing the Biotubes’ entire surface for filtering. Particles larger than the Biotube’s mesh are prevented from leaving the tank. Optional Features & Benefits Biotube Filtering Process 8-in. (200-mm) Base Inlet Filter 4-in. (100-mm) Insert Filter 4-in. (100-mm) Biotube Jr. (4-in. Biotube cartridge avail- able separately as Insert Filter) Orenco’s superior effluent filters resist clogging better than all other brands. Our stan- dard, full-sized 4-in. (100-mm) Biotube Effluent Filter provides maximum long-term protection in a complete package, with housing. Our 4-in. (100-mm) Biotube Jr., at half the size of our standard model, has more filtering capacity than the full-sized filters sold by other manufacturers. For tanks with existing outlet tees, the Biotube Insert Filter is ideal. And for low-profile tanks, there’s the Base Inlet Filter. * Covered by patent numbers 5,492,635 and 4,439,323 4-in. (100-mm) Biotube Effluent Filter APS-FT-1 Rev. 3.4 © 11/10 Orenco Systems®, Inc. To Order Call your nearest Orenco Systems®, Inc. distributor. For nearest distribu- tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on “Distributor Locator.” Nomenclatures Riser wall Tank wall Filter housing Extendible PVC handle Stainless steel set screws Top seal plate Air vents Biotube® filter cartridge Solid base 4-in. Biotube Effluent Filter 4-in. Biotube Jr. 4-in. Biotube Filter (standard) 4-in. Biotube Jr. (includes cartridge and housing) Distributed By: 8-in. Biotube Filter (base inlet model) 4-in. Biotube Filter Insert (cartridge only) Junior series FT J0418 Biotube effluent filter series Filter diameter (inches) Cartridge height (inches) W = fits Type 3034 outlet tee S = fits Schedule 40 outlet tee Options: Blank = no options M = flow modulation plate installed A = float bracket attached Blank = 1/8" filtration P = 1/16" filtration Insert FT i0418 Biotube effluent filter series Filter diameter (inches) Cartridge height (inches) W = fits Type 3034 outlet tee S = fits Schedule 40 outlet tee - For customized options (e.g., NC indicates North Carolina regions) - Blank = 1/8" filtration P = 1/16" filtration FT 04 Biotube effluent filter series Filter diameter (inches) Housing height: 36" and 44" are standard Options: Blank = no options M = flow modulation plate installed A = float bracket attached Cartridge height: 28" and 36" are standard - Blank = 1/8" filtration P = 1/16" filtration W = fits Type 3034 outlet pipe S = fits Schedule 40 outlet pipe FT 2208 14 B Biotube effluent filter series Housing height: 22" standard Cartridge height: 14" standard Options: A = float bracket FS = 2" outlet orifice FSO = 2" outlet orifice and overflow plate* Base inlet model - Blank = 1/8" filtration P = 1/16" filtration Filter diameter (inches) 08 = 8" * Also available with coupling and sleeve as a “kit”: FT-OVERFLOWKIT The Quick4® Plus Standard Chamber The Quick4 Plus Standard Chamber offers maximum strength through its two center structural columns. This chamber can be installed in a 36-inch-wide trench. Like the original line of Quick4 chambers, it offers advanced contouring capability with its Contour Swivel Connection™ which permits turns up to 15-degrees, right or left. It is also available in four-foot lengths to provide optimal installation flexibility. The Quick4 Plus All-in-One 12 Endcap, and the Quick4 Periscope are available with this chamber, providing increased flexibility in system configurations. Maximum Strength APPROVED in _____________________________________________ Quick4 Plus™ Series Quick4 Plus All-in-One 12 Endcap Benefits: • May be used at the end of chamber row for an inlet/outlet or can be installed mid-trench • Mid-trench connection feature allows construction of chamber rows with center feed, as an alternative to inletting at the ends of chamber rows • Center-feed connection allows for easy installation of serial distribution systems • Pipe connection options include sides, ends or top Quick4 Plus All-in-One Periscope Benefits: • Allows for raised invert installations • 180° directional inletting • 12” raised invert is ideal for serial applications Certified by the International Association of Plumbing and Mechanical Officials (IAPMO) Quick4 Plus Standard Chamber Specifications Size 34”W x 53”L x 12”H (864 mm x 1346 mm x 305 mm) Effective Length 48” (1219 mm) Louver Height 8” (203 mm) Storage Capacity 47 gal (178 L) Invert Height 0.6” (15 mm), 5.3” (135 mm), 8.0” (203 mm), 12.7” (323 mm) Quick4 Plus Standard Chamber Benefits: • Two center structural columns offer increased stability and superior strength • Advanced contouring connections • Latching mechanism allows for quick installation • Four-foot chamber lengths are easy to handle and install • Supports wheel loads of 16,000 lbs/axle with 12” of cover Contact Infiltrator Water Technologies’ Technical Services Department for assistance at 1-800-221-4436 4 Business Park Road P.O. Box 768 Old Saybrook, CT 06475 860-577-7000 • Fax 860-577-7001 1-800-221-4436 www.infiltratorwater.com U.S. Patents: 4,759,661; 5,017,041; 5,156,488; 5,336,017; 5,401,116; 5,401,459; 5,511,903; 5,716,163; 5,588,778; 5,839,844 Canadian Patents: 1,329,959; 2,004,564 Other patents pending. Infiltrator, Equalizer, Quick4, and SideWinder are registered trademarks of Infiltrator Water Technologies. Infiltrator is a registered trademark in France. Infiltrator Water Technologies is a registered trademark in Mexico. Contour, MicroLeaching, PolyTuff, ChamberSpacer, MultiPort, PosiLock, QuickCut, QuickPlay, SnapLock and StraightLock are trademarks of Infiltrator Water Technologies. PolyLok is a trademark of PolyLok, Inc. TUF-TITE is a registered trademark of TUF-TITE, INC. Ultra-Rib is a trademark of IPEX Inc. © 2013 Infiltrator Water Technologies, LLC. All rights reserved. Printed in U.S.A.PLUS05 0713 Quick4 Plus™ Series INFILTRATOR WATER TECHNOLOGIES STANDARD LIMITED WARRANTY (a) The structural integrity of each chamber, endcap and other accessory manufactured by Infiltrator (“Units”), when installed and operated in a leachfield of an onsite septic system in accordance with Infiltrator’s instructions, is warranted to the original purchaser (“Holder”) against defective materials and workmanship for one year from the date that the septic permit is issued for the septic system containing the Units; provided, however, that if a septic permit is not required by applicable law, the warranty period will begin upon the date that installation of the septic system commences. To exercise its warranty rights, Holder must notify Infiltrator in writing at its Corporate Headquarters in Old Saybrook, Connecticut within fifteen (15) days of the alleged defect. Infiltrator will supply replacement Units for Units determined by Infiltrator to be covered by this Limited Warranty. Infiltrator’s liability specifically excludes the cost of removal and/or installation of the Units. (b) THE LIMITED WARRANTY AND REMEDIES IN SUBPARAGRAPH (a) ARE EXCLUSIVE. THERE ARE NO OTHER WARRANTIES WITH RESPECT TO THE UNITS, INCLUDING NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE (c) This Limited Warranty shall be void if any part of the chamber system is manufactured by anyone other than Infiltrator. The Limited Warranty does not extend to incidental, consequential, special or indirect damages. Infiltrator shall not be liable for penalties or liquidated damages, including loss of production and profits, labor and materials, overhead costs, or other losses or expenses incurred by the Holder or any third party. Specifically excluded from Limited Warranty coverage are damage to the Units due to ordinary wear and tear, alteration, accident, misuse, abuse or neglect of the Units; the Units being subjected to vehicle traffic or other conditions which are not permitted by the installation instructions; failure to maintain the minimum ground covers set forth in the installation instructions; the placement of improper materials into the system containing the Units; failure of the Units or the septic system due to improper siting or improper sizing, excessive water usage, improper grease disposal, or improper operation; or any other event not caused by Infiltrator. This Limited Warranty shall be void if the Holder fails to comply with all of the terms set forth in this Limited Warranty. Further, in no event shall Infiltrator be responsible for any loss or damage to the Holder, the Units, or any third party resulting from installation or shipment, or from any product liability claims of Holder or any third party. For this Limited Warranty to apply, the Units must be installed in accordance with all site conditions required by state and local codes; all other applicable laws; and Infiltrator’s installation instructions. (d) No representative of Infiltrator has the authority to change or extend this Limited Warranty. No warranty applies to any party other than the original Holder. The above represents the Standard Limited Warranty offered by Infiltrator. A limited number of states and counties have different warranty requirements. Any purchaser of Units should contact Infiltrator’s Corporate Headquarters in Old Saybrook, Connecticut, prior to such purchase, to obtain a copy of the applicable warranty, and should carefully read that warranty prior to the purchase of Units. Quick4 Plus Standard Chamber ___________________________________________________________________________________ Quick4 Plus All-in-One 12 Endcap ________________________________________________________________________________ Quick4 Plus All-in-One Periscope ________________________ EFFECTIVE LENGTH48" 12" 34" QUICK4 PLUS ALL-IN-ONE PERISCOPE (360° SWIVEL) 12.7" INVERT PRESSURIZED PIPE DRILL POINTS LOCATIONS (2 PLACES) 33" 18" 8" INVERT 13" EFFECTIVE LENGTH48" 12" 34" QUICK4 PLUS ALL-IN-ONE PERISCOPE (360° SWIVEL) 12.7" INVERT PRESSURIZED PIPE DRILL POINTS LOCATIONS (2 PLACES) 33" 18" 8" INVERT 13" FRONT VIEW SIDE VIEW EFFECTIVE LENGTH48" 12" 34" QUICK4 PLUS ALL-IN-ONE PERISCOPE (360° SWIVEL) 12.7" INVERT PRESSURIZED PIPE DRILL POINTS LOCATIONS (2 PLACES) 33" 18" 8" INVERT 13" 6" 5"9"