Permit
Permit No. OWTS-016394-2019
Permit Type: OWTS Permit
Work Classification: New
Permit Status: Active
Issue Date: 9/17/2019 Expires: 8/30/2019
On-Site Wastewater
Treatement System
Project Address Parcel Number
0 Wolcott Spring Rd STE Parcel 3, Wolcott, 81632 194126300066
Owner Information Address
Travis Fahrney 12 Stillwater
Edwards, CO 81632
Phone: (970) 376-7113
Cell: (970) 376-7113
Email: travisfahrney@gmail.com
Inspections:
For Inspections Call: (970) 328-8755
and call the Design Engineer
Engineer Phone Email
LKP Engineering, Inc., Luiza Petrovska, PE (970) 390-0307 luiza@lkpeng.com
Contractor License Number Phone Email
Bossow Excavation LLC richiebossow@yahoo.com(970) 376-6310OWTSPL-000050-20
19
Permitted Construction / Details:
Install the OWTS exactly as depicted in the LKP Engineering revised design dated August 17, 2019, stamped and
signed by Luiza K. Petrovska P.E. The system is designed to serve a two bedroom single family residence.
The OWTS consists of a 1,000 gallon three compartment Valley Precast septic tank with a 1,500 gallon total effective
volume (Item #1000T-3CP-F-D3), equipped with a dosing siphon in the third compartment, and and effluent filter in
the tee between the second and third compartment. Set the dosing float to pressure dose 181.80 gallons
approximately 92 feet to a soil treatment area consisting of two equal trenches each with 19 Infiltrator Quick4 Plus
Standard chambers set atop two feet of secondary sand filter media. Clear and rake trench sidewalls and bottoms to
prevent smearing, immediately prior to placement of aggregate sand. Construction must only be started when the
soil site is suitably dry. Maintain all elevations as shown of the engineer's site plan.
Contact the design engineer and Eagle County Environmental Health well in advance to conduct of requesting
inspections. All inspections necessary to certify proper installation must be performed by the design engineer.
System certification along with photos and a record drawing are required to be submitted to, and approved by,
Eagle County Environmental Health prior to the use of the system and occupancy of the residence.
THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF
ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
Issued by: Environmental Health Department, Eagle County, CO
Claire Lewandowski
Date
September 17, 2019
CONDITIONS
1.
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS,
ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Wednesday, September 25, 2019 1
Defina Construction
4140
definaconst@aol.com376-6702
May 20, 2020
Sarah and Travis Fahrney
PO Box 6384
Avon, CO 81620
sfahrney@vailbooks.com
RE: Final approval of the: Septic System Installation, OWTS-016394-2019
Property location: 2600 Wolcott Springs Rd, Eagle County
Mr. and Mrs. Fahrney,
This letter is to inform you that the above-referenced permit has been inspected and finalized.
The Onsite Wastewater Treatment System (OWTS) was designed and installed to serve the two
bedroom residence on the above property.
Additional information about the maintenance your septic system needs can be accessed through
our website links, provided on the Environmental Health Department’s septic system resource page.
Be aware that changes in the use of your property or alterations of your building may require
commensurate changes to, or relocation of, your septic system. Landscape features, trees with tap
roots, irrigation systems and parking areas above the soil treatment area can cause premature
system failure. It is equally important that you notice and immediately repair dripping faucets and
hissing toilets as this will certainly cause the system to fail.
If you have any questions regarding this information, please contact us at (970) 328 -8755 and
reference the OWTS septic permit number.
Best Regards,
Claire Lewandowski, REHS
Environmental Health Specialist III
Attachments: Certification Letter and Design – Septic System Flyer – Final Letter
PUBLIC HEALTH & ENVIRONMENT
(970) 328-8755
FAX: (970) 328-8788
environment@eaglecounty.us
!
G The property is on
Wolcott Springs Road.Wolcott, Colorado
G Parcel 3, Wolcott Springs Subdivision, Eagle County,
Colorado. Parcel Number 1941-263-00-066
G There are no existing structures on the property. It is
a vacant land.
G There is a new well
on the property.
G There
are no records of existing septic system on the property.
G The topography of the leachfield site has a moderate slope of
18 percent.
G The profile holes were excavated and observed on August 9,
2019. The soil exposed in the profile holes was as follows:
Profile Hole #1
0 to 4 feet topsoil and clay
4 to 8 feet light brown clay, sandy, gravelly with
angular cobbles and boulders
No ground water encountered
Type 4, R-1, Option 1
Profile Hole No. 2
0 to 4 feet topsoil and clay
4 to 8 feet light brown clay, sandy, gravelly with angular cobbles and
boulders
No ground water encountered
Type 4, R-1, Option 1
G
!
G The proposed leachfield site will be located in the
Back /Side Position of the site and northeast of the proposed residence.
G The topography of the proposed leachfield site is moderate.
G The vegetation within the proposed leachfield site was thick
and it consisted of grass, sage brush, service berries, and some juniper
trees. The site surrounding the leachfield was similar.
G The property is on Bellyache Ridge within
the Wolcott Springs Subdivision. The building site is about 4500 feet south
from Interstate 70 and Eagle River and about 800 feet above. It is also
about 2300 feet west from Travis Creek and about a mile west from the
Red Sky Ranch Golf Course. The area is mountainous with pine forest and
meadows.
G The current use is residential. Previous use
was sheep grazing.
!
G
G
!
G
This site
evaluation was completed by Luiza Petrovska, PE, of LKP Engineering,
Inc. LKP Engineering, Inc., is located at 67 Robins Egg Lane, Eagle,
Colorado. The phone number is 970-390-0307 and Luiza=s email is
luiza@lkpeng.com
G August 9, 2019.
G Attached
G from STA (Soil Treatment Area) to tank,
about 90 feet, STA to building about 120 feet, STA to the north property
line about 420 feet, to west about 500 feet, to the south about 168 feet, and
to the east over 1000 feet, septic tank to building about 23 feet. From the
well to the STA is about 223 feet and to the septic tank about 120 feet.
G : Items 1-4, observed. from well to STA 223
feet, no pond, dry gulch or cut bank.
G
#
#
#
#
#
#
#
G The distance from gravel pits for
the delivery of the sand filter material.
G
None known
G
Finding suitable site without bedrock or large sandstone rocks required
digging profile holes in multiple areas.
G
(36" WIDE TRENCH)
INFILTRATOR SYSTEMS INC.
QUICK4 PLUS STANDARD CHAMBER
TYPICAL TRENCH DETAIL
SECTION VIEW
(NOT TO SCALE)
NATIVE BACKFILL
TOPSOIL
2'2'
SAND FILTER
4' MINIMUM
CUT OUT FOR PRESSURE
DISTRIBUTION LINES
4-FT MAX.SAND FILL PLACEMENT
PLACE THE SAND FILL MATERIAL IN THE EXCAVATED TRENCHES.
THE FILTERING MATERIAL USED IN A SAND FILTER MUST BE CLEAN, COARSE SAND, CLASSIFIED AS
PRIMARY SAND OR SECONDARY SAND. THE ABOVE DESIGN WAS PREPARED BASED ON SECONDARY SAND.
THE CLASSIFICATION OF THE SAND TO BE USED IN THE TRENCHES OF THE SOIL TREATMENT AREA (STA)
MUST BE LESS THAN 30 DAYS OLD AND SUBMITTED TO THE ENGINEER PRIOR TO THE SAND FILL
PLACEMENT.
PROFILE HOLE #1
0 TO 4 FEET TOPSOIL AND CLAY
4 TO 8 FEET LIGHT BROWN, CLAY, SANDY,
GRAVELLY WITH COBBLES AND BOULDERS
ANGULAR
NO GROUND WATER ENCOUNTERED
TYPE 4, R-1, OPTION 1
DESIGN CALCULATIONS
TYPE 4 SOIL, R-1, OPTION 1 WITH >35%-65% ROCK (>2MM); WITH 50% OF THE ROCK <3/4" .
PRESSURIZED DISTRIBUTION WITH A MINIMUM OF 2 FOOT DEEP UNLINED SAND FILTER
LTAR FOR DESIGN = 0.8GPD/SF
NUMBER OF BEDROOMS = 2
MAXIMUM DAILY FLOW = QMAX
QMAX = 2 BEDROOMS X 2 PERSONS/BEDROOM X 75 GALLONS/PERSON/DAY
QMAX = 300 GPD
SEPTIC TANK
PLUS 250 GALLONS FOR EACH ADDITIONAL BEDROOM
USE 1000 GALLONS, THREE-COMPARTMENTS, ELECTRIC LIFT SEPTIC TANK WITH AN EFFLUENT
FILTER BY VALLEY PRECAST
ABSORPTION AREA
ABSORPTION AREA
BASED ON APPLICATION RATE:
A = 300GPD/0.8GPD/S.F.
A = 375S.F.
QUICK 4 PLUS, STANDARD INFILTRATOR CHAMBER SYSTEM IN A TRENCH CONFIGURATION
CONSTRUCTED OVER 2 FEET OF UNLINED SAND FILTER. NO REDUCTION FOR FOR R TYPE SOILS.
SURFACE AREA OF ONE QUICK4, PLUS STANDARD INFILTRATOR CHAMBER = 12 S.F.
USE 32 QUICK4, PLUS, STANDARD, INFILTRATOR CHAMBERS IN TRENCHES AS SHOWN ON THE
PLAN.
PROFILE HOLE #2
0 TO 4 FEET TOPSOIL AND CLAY
4 TO 8 FEET LIGHT BROWN, CLAY, SANDY,
GRAVELLY WITH COBBLES AND BOULDERS
ANGULAR
NO GROUND WATER ENCOUNTERED
TYPE 4, R-1, OPTION 1
SQUIRT TEST OF THE RESIDUAL HEAD OF THE STA
LATERALS
REMOVE THE END CAPS OF THE FLUSHING
ASSEMBLY IN ORDER TO FLUSH THE LATERALS
CLEAN FROM ANY DRILLING DEBRIS OR DIRT. DO
NOT INSTALL THE LAST INFILTRATOR CHAMBER
SO THAT THE PERFORATIONS ON THE LATERALS
ARE OPEN IN ORDER TO RUN THE SQUIRT TEST
FOR THE MEASUREMENT OF THE 4-FT RESIDUAL
HEAD (+/-10%). THE PREPARATIONS FOR THE
SQUIRT TEST MUST BE READY FOR THE TEST TO
BE DONE DURING THE FINAL INSPECTION.
AFTER THE TEST, INSTALL THE LAST CHAMBER ON
ALL ROWS.
OWTS X-SECTION SKETCH
N.T.S
LOWEST FLOOR
ELEVATION=7788'
INVout=7784''
INVin=7783.4'
INVin=7773'
PRESSURE
DISTRIBUTION LINES
PROPOSED
RESIDENCE RIM EL=7787'
ABOUT 30 FEET, 4-INCH
DIAMETER, SDR35 PVC, BUILDING
SEWER LINE AT 2% SLOPE FOR
THE FIRST AND LAST FIVE FEET
ABOUT 92 FEET OF 4-INCH SCH40
PVC TRANSPORT (EFFLUENT LINE)
(36" WIDE TRENCH)
NATIVE BACKFILL
TOPSOIL
2'2'
SAND FILTER
4' MINIMUM
MANIFOLD
INV out ~7780.65'
PROFILE
HOLE - 1
Wolcott Springs Road
50' private road
PROFILE
HOLE - 2
PROPANE TANK
PROPO
S
E
D
RESIDE
N
C
E
FF EL ~
7
7
8
8
'
(TO BE V
E
R
I
F
I
E
D
A
T
CONSTR
U
C
T
I
O
N
)
WELL
ELECTRICAL
UTILITY
CONNECTION
Parcel 3
37.001 Acres
vacant
~30 FEET SDR35 BUILDING SEWER LINE.
SET THE FIRST AND THE LAST 5 FEET OF
THE PIPE AT 2% SLOPE
(INSULATE THE PIPE WHERE DEPTHS ARE
LESS THAN 4 FEET BELOW FINISH GRADE)
223'
+/-
T
O
W
E
L
L
INVout=7784'
CLEANOUT
~507' TO WESTERN
PROPERTY LINE
ABOUT 420' TO
THE NORTHERN
PROPERTY LINE
~168'+/- TO THE
SOUTH
PROPERTY
LINE
12'
40'
INVin=7783.4'
INVin=7773'
1000 GALLONS TOP SEAM - 3
COMPARTMENT CONCRETE SEPTIC
TANK BY VALLEY PRECAST WITH
EFFLUENT FILTER, 300 SERIES SIPHON,
MODEL OSI318, AND BATTERY COUNTER
ABOUT 92FEET OF 4-INCH
SCH40 PVC TRANSPORT
(EFFLUENT LINE)
INV out ~7780.65'
CLEANOUT W/3/16-IN HOLE
DRILLED AT THE TOP
~66', 2-INCH DIAMETER
LATERALS, PERFORATED
WITH 3/16-INCH HOLES AT
3-FOOT INTERVALS AT
THE TOP OF THE LATERAL
NUMBER OF INFILTRATOR
CHAMBERS PER ROW
FLUSHING ASSEMBLY
(TYPICAL)19
DRILL ONE 1/4-INCH HOLE AT THE INVERT
OF THE FAR END OF THE LATERAL FOR
DRAINING OF THE REMAINING EFFLUENT
FROM THE PIPE BETWEEN DOSING AND
PLACE A ROCK UNDER IT TO PREVENT
EROSION (TYPICAL)
19
~7 FEET, 2-INCH DIAMETER,
SCH40PVC, MANIFOLD
INSPECTION PORT (TYPICAL) IN THE FIRST
AND LAST INFILTRATOR CHAMBER OF EACH
ROW OF INFILTRATORS, INSTALLED IN THE
OPENING OF THE END CAP OPPOSITE OF
THE PRESSURE LATERALS
QUICK 4 PLUS, STANDARD
INFILTRATOR CHAMBER
(TYPICAL)
FIRE TRUCK AND EMERGENCY
VEHICLE PULLOUT WITH YEAR
ROUND ACCESS
FIRE PROTECTION WATER STORAGE IN 4
2400-GALLON CONCRETE TANKS FOR A
TOTAL OF 9600 GALLONS BY FRONT
RANGE PRECAST OR EQUIVALENT22.50'
INFILTRATOR SYSTEMS INC.
QUICK4 PLUS STANDARD CHAMBER
PRODUCT SPECIFICATION
(NOT TO SCALE)
PRESSURIZED PIPE DRILL
POINTS LOCATIONS
(2 PLACES)
(EFFECTIVE LENGTH)
TOP VIEW
SIDE VIEW END VIEW
QUICK4 PLUS ALL-IN-ONE 12 END CAP
INSPECTION PORT
(EFFECTIVE LENGTH)
SIDE VIEW
Valve Box
Ball Valve
Sweeping Ell
FLUSHING ASSEMBLY
N.T.S.
OPEN BOTTOM
VENT CAP
OPEN BOTTOM
VENT CAP
INSPECTION PORT
4-INCH DIAMETER SDR35 WITH
PERFORATIONS ON THE BOTTOM
8-INCHES
2'
12"+
ATTACH TO
INFILTRATOR WITH
A RING OR
SCREWS
INSPECTION PORT
N.T.S.
FINISHED
GRADE
PRESSURE
DISTRIBUTION
LINES
(109.32' PLAT)
PARENTHESIS DENOTE CURVE DATA ACCORDING TO
"LAND SURVEY PLAT OF PARCELS 1, 2, 3, 4, 7, &
8 WOLCOTT SPRINGS PARCELS" WHERE PLATTED
CURVE DATA DIFFERS FROM ACTUAL CALCULATED
CURVE DATA.
Wolcott Springs Road
50' private road
Wo
l
c
o
t
t
S
p
r
i
n
g
s
R
oa
d
50'
p
r
i
v
a
t
e
r
o
a
d
Parcel 2
Parcel 1
PROPOSEDRESIDENCEFF EL ~ 7788'
WELL Parcel 3
37.001 Acres
vacant
Parcel 3
37.001 Acres
vacant
12'
40'
FIRE TRUCK AND EMERGENCY
VEHICLE PULLOUT WITH YEAR
ROUND ACCESS
FIRE PROTECTION WATER STORAGE IN 4
2400-GALLON CONCRETE TANKS FOR A
TOTAL OF 9600 GALLONS BY FRONT
RANGE PRECAST OR EQUIVALENT
NOTE:
- THE SITE PLAN WAS EMAILED BY JACK
SUNDERLAND, SUNDER, INC.
- TOPOGRAPHICAL SURVEY BY ARCHIBEQUE
LAND CONULTING, LTD.
NOTES:
1. BENDS IN THE BUILDING SEWER SHALL BE LIMITED TO 45 DEGREES.
2. THE SEPTIC TANK SHALL BE INSTALLED LEVEL.
3. THE TANK SHALL HAVE RISERS OVER EACH ACCESS MANHOLE AND ALL RISERS SHALL EXTEND TO OR ABOVE FINAL GRADE.
4. EACH RISER LEAD WILL HAVE A SECURE CLOSING MECHANISM, SUCH AS A LOCK, SPECIAL HEADED BOLTS OR SCREWS, OR SUFFICIENT
WEIGHT TO PREVENT UNAUTHORIZED ACCESS.
5.THE SEPTIC TANK AND ALL THE PIPING WILL BE BACKFILLED UP TO THE INVERTS PRIOR TO SCHEDULING AN INSPECTION.
6. THE INFILTRATOR TRENCHES SHALL BE INSTALLED LEVEL, ALONG THE CONTOUR.
7. EXCAVATE THREE (3) FEET WIDE TRENCHES
8. THE BOTTOM AND THE SIDEWALLS OF THE TRENCHES SHALL BE RAKED (IF NEEDED) TO ELIMINATE SMEARING.
8. THE TRENCHES WILL BE EXCAVATED TO A DEPTH OF FOUR FEET ON THE HIGH SIDE OF THE TRENCH PLUS AN ADDITIONAL TWO FEET FOR THE
SAND FILTER PLACEMENT.
9. MARK A LINE IN THE TRENCHES AT THE 2-FOOT DEPTH FROM THE BOTTOM WITH SPRAY PAINT BEFORE THE SAND PLACEMENT
10. PLACE THE SEND FILTER IN THE PREPARED TRENCHES TO THE MARKED DEPTH
11. ASSEMBLE AND INSTALL THE INFILTRATOR CHAMBERS IN THE TRENCHES ACCORDING TO THE MANUFACTURERS RECOMMENDATIONS.
12. INSTALL THE PERFORATED PRESSURE DISTRIBUTION LATERALS ACCORDING TO THE MANUFACTURERS RECOMMENDATIONS.
13. SCHEDULE A SQUIRT TEST OF THE LATERALS
14. BACKFILL THE SIDEWALL AREA WITH NATIVE ON-SITE SOIL FOR PROPER SUPPORT.
15. BACKFILL THE TRENCHES WITH A MINIMUM OF 12 INCHES OF TAMPED SOIL COVER.
16. AVOID VEHICLE TRAFFIC OVER THE SYSTEM.
17. ALL INSTALLATIONS SHALL MEET THE RULES AND REGULATIONS OF THE EAGLE COUNTY ENVIRONMENTAL HEALTH DEPARTMENT AND OWTS
REG 43 EFFECTIVE AUGUST 24, 2018 .
18.FOR THE INSPECTION OF THE SEPTIC SYSTEM - NOTIFY THE EAGLE COUNTY ENVIRONMENTAL HEALTH DEPARTMENT AND THE DESIGN
ENGINEER A MINIMUM OF 48-HOURS PRIOR TO BACKFILLING ANY PART OF THE SYSTEM TO SCHEDULE AN INSPECTION.
DRAWN BY:
CHECKED BY:
PROJECT NO.:
SHEET:
DRAWING NO.:
DATE:BYDESCRIPTIONDATENO.L.P.
L.P.
C-1
18-3277
AUGUST 17, 2019
18-3277OWTS.DWGONSITE WASTEWATER TREATMENT SYSTEMPARCEL 3, WOLCOTT SPRINGS SUBDIVISIONWOLCOTT SPRINGS ROADEAGLE COUNTY, COLORADOPREPARED FORP.O. Box 724 EAGLE, CO 81631Tel (970) 390-0307www.LKPEngineering.comSARAH FAHRNEYMAP
~1"=300'
GRADATION ANALYSIS TEST
LABORATORY TEST REPORT DATA
Laboratory
Client:
Location / Plant:
Sample / Product:
Sample Date:
Lab Test Date:
Job Number:
SIEVE SIEVE OPENING IN
MILLIMETERS
PERCENT
PASSING THRU
SIEVE
3"75 100.0
1.5 37.5 100.0
3/4"19 100.0
3/8"9.5 100.0
No. 4 4.75 100.0
No. 8 2.36 87.0
No. 16 1.18 70.0
No. 30 0.6 47.0
No. 50 0.3 20.0
No. 100 0.15 5.0
No. 200 0.075 1.7
GRADATION RESULTS COMPARED TO PREFERRED AND SECONDARY SAND FILTER SPECIFICATIONS
Value Units
Preferred
Sand Value
Pass / Fail
Preferred
Sand
Secondary
Sand Value
Pass / Fail
Secondary
Sand
0.93 millimeters
0.200 millimeters 0.25 to 0.60 FAIL 0.15 to 0.60 PASS
4.64 unitless ratio < or = 4.0 FAIL < or = 7.0 PASS
1.7 millimeters < or = 3 PASS < or = 3 PASS
Uniformity Coefficient (D60 / D10)
Percent passing thru #200 Sieve
Parameter
D60 - Diameter that 60 percent of the sample is
finer than.
Effective Size - D10 - Diameter that 10 percent
of the sample is finer than.
ENTER INFORMATION IN BLUE CELLS
0
10
20
30
40
50
60
70
80
90
100
0.01 0.1 1 10 100Percent Passing SieveDiameter of Particle in Millimeters
Plot of Gradation Analysis
3"1.5"3/4"3/8"#4#8#30#50#100#200 #16
G:\Shared drives\ENV Department\OWTS & WASTEWATER\PERMITS\2019 Septic\OWTS-016394-2019 - Travis Fahrney - Final\Final Sand Gradation Analysis Spreadsheet
GRADATION ANALYSIS TEST
LABORATORY TEST REPORT DATA
Laboratory
Client:
Location / Plant:
Sample / Product:
Sample Date:
Lab Test Date:
Job Number:
SIEVE SIEVE OPENING IN
MILLIMETERS
PERCENT
PASSING THRU
SIEVE
3"75 100.0
1.5 37.5 100.0
3/4"19 100.0
3/8"9.5 100.0
No. 4 4.75 100.0
No. 8 2.36 87.0
No. 16 1.18 70.0
No. 30 0.6 47.0
No. 50 0.3 20.0
No. 100 0.15 5.0
No. 200 0.075 1.7
GRADATION RESULTS COMPARED TO PREFERRED AND SECONDARY SAND FILTER SPECIFICATIONS
Value Units
Preferred
Sand Value
Pass / Fail
Preferred
Sand
Secondary
Sand Value
Pass / Fail
Secondary
Sand
0.93 millimeters
0.200 millimeters 0.25 to 0.60 FAIL 0.15 to 0.60 PASS
4.64 unitless ratio < or = 4.0 FAIL < or = 7.0 PASS
1.7 millimeters < or = 3 PASS < or = 3 PASS
Uniformity Coefficient (D60 / D10)
Percent passing thru #200 Sieve
Parameter
D60 - Diameter that 60 percent of the sample is
finer than.
Effective Size - D10 - Diameter that 10 percent
of the sample is finer than.
ENTER INFORMATION IN BLUE CELLS
0
10
20
30
40
50
60
70
80
90
100
0.01 0.1 1 10 100Percent Passing SieveDiameter of Particle in Millimeters
Plot of Gradation Analysis
3"1.5"3/4"3/8"#4#8#30#50#100#200 #16
G:\Shared drives\ENV Department\OWTS & WASTEWATER\PERMITS\2019 Septic\OWTS-016394-2019 - Travis Fahrney - Final\Final Sand Gradation Analysis Spreadsheet
GRADATION ANALYSIS TEST
LABORATORY TEST REPORT DATA
Laboratory
Client:
Location / Plant:
Sample / Product:
Sample Date:
Lab Test Date:
Job Number:
SIEVE SIEVE OPENING IN
MILLIMETERS
PERCENT
PASSING THRU
SIEVE
3"75 100.0
1.5 37.5 100.0
3/4"19 100.0
3/8"9.5 100.0
No. 4 4.75 100.0
No. 8 2.36 99.2
No. 16 1.18 92.9
No. 30 0.6 60.0
No. 50 0.3 17.4
No. 100 0.15 2.6
No. 200 0.075 1.0
GRADATION RESULTS COMPARED TO PREFERRED AND SECONDARY SAND FILTER SPECIFICATIONS
Value Units
Preferred
Sand Value
Pass / Fail
Preferred
Sand
Secondary
Sand Value
Pass / Fail
Secondary
Sand
0.60 millimeters
0.225 millimeters 0.25 to 0.60 FAIL 0.15 to 0.60 PASS
2.66 unitless ratio < or = 4.0 PASS < or = 7.0 PASS
1.0 millimeters < or = 3 PASS < or = 3 PASS
Uniformity Coefficient (D60 / D10)
Percent passing thru #200 Sieve
Parameter
D60 - Diameter that 60 percent of the sample is
finer than.
Effective Size - D10 - Diameter that 10 percent
of the sample is finer than.
ENTER INFORMATION IN BLUE CELLS
Alma
C-33 Leachfield
05/19/2014
0
10
20
30
40
50
60
70
80
90
100
0.01 0.1 1 10 100Percent Passing SieveDiameter of Particle in Millimeters
Plot of Gradation Analysis
1.5"3/4"#4#8#16#30#50#100#200 3/8"3"
G:\Shared drives\ENV Department\OWTS & WASTEWATER\PERMITS\2019 Septic\OWTS-016394-2019 - Travis Fahrney - Final\Final Sand Gradation Analysis Spreadsheet
Plant 102_01202-Eagle
Basic Quality Statistical Summary Report
Sieve/Test SpecificationAverageSt DevTests
Product 14111-Gypsum 1/4" Concrete Sand
Target
Specification CDOT Fine Aggregate
Period 05/07/2019 - 11/07/2019
1/2" (12.5mm)100 0.187
3/8" (9.5mm)100 0.3 100-10087
#4 (4.75mm)100 0.5 95-10087
#8 (2.36mm)87 0.9 80-10087
#16 (1.18mm)70 1.9 50-8587
#30 (0.6mm)47 1.9 25-6087
#50 (0.3mm)20 1.8 10-3087
#100 (0.15mm)5 1.5 2-1087
#200 (75µm)1.7 1.24 0-387
Pan 0.0 0.0087
Query Query Selections
Date Created 11/07/2019
Date Range 05/07/2019 - 11/07/2019
Plant Eagle
1Page:of 1CRH Americas Materials (AMAT)StonemontQC 11/07/2019
Siphon Dosing Calculations
Company:LKP Engineering, Inc.
Ph / Fax:970-390-0307
Project Name:Fahrney Residence
Prepared by:Luiza Petrovska, PE
Input:
Siphon Model:318
Length of Run (ft):92 feet
Fall (ft):7.65 feet
Number of Orifices:34
Orifice Diameter (in):0.1875 inches
Squirt Height (ft):4 feet
Transport Line Size (in):4 inches
Pipe Class/Schedule:40 4.00
Dose Chamber Volume Per Inch (gal/in):10.10 gallons/inch
Volume of Lateral and Manifold Piping:25.00 gallons
(If orifices are orientated upwards and piping 30.00
will remain full between doses - Enter " 0 ")
Calculation:
Approximate Flow Rate Required to Pressurize System (gpm): 29.60 gpm
Siphon Discharge Rate (gpm):76.00 gpm
Siphon Drawdown (in):18.00 inches
Dose Volume (gal):181.80 gallons
Approximate Gallons Required to Fill Transport 73.75
Line to the Required Squirt Height:73.75 gallons
Approximate Time For Siphon Discharge:143.53 seconds
Approximate Time Required to Fill Transport
Line to the Required Squirt Height:58.22 seconds
34.54
Percent of Dose Required to Pressurize the System to the
Required Squirt Height (Dose Volume/Gallons Required): 40.57 %40.57%
Acceptable Values are 0 - 50%.
Analyze Result:
"Error's" or "Caution's" regarding the Inputs and Calculations are listed below.
NDA-SIPH-HYD-1
Rev. 2 04/25/03
GRADATION ANALYSIS TEST
LABORATORY TEST REPORT DATA
Laboratory
Client:
Location / Plant:
Sample / Product:
Sample Date:
Lab Test Date:
Job Number:
SIEVE SIEVE OPENING IN
MILLIMETERS
PERCENT
PASSING THRU
SIEVE
3"75
1.5 37.5
1/2"12.5 100.0
3/8"9.5 100.0
No. 4 4.75 100.0
No. 8 2.36 87.0
No. 16 1.18 70.0
No. 30 0.6 45.0
No. 50 0.3 20.0
No. 100 0.15 5.0
No. 200 0.075 1.7
GRADATION RESULTS COMPARED TO PREFERRED AND SECONDARY SAND FILTER SPECIFICATIONS
Value Units
Preferred
Sand Value
Pass / Fail
Preferred
Sand
Secondary
Sand Value
Pass / Fail
Secondary
Sand
0.95 millimeters
0.200 millimeters 0.25 to 0.60 FAIL 0.15 to 0.60 PASS
4.74 unitless ratio < or = 4.0 FAIL < or = 7.0 PASS
1.7 millimeters < or = 3 PASS < or = 3 PASS
Uniformity Coefficient (D60 / D10)
Percent passing thru #200 Sieve
Parameter
D60 - Diameter that 60 percent of the sample is
finer than.
Effective Size - D10 - Diameter that 10 percent
of the sample is finer than.
ENTER INFORMATION IN BLUE CELLS
102_01202-Eagle
14111-Gypsum 1/4" Concrete Sand
05/07/2019 -11/07/2019
0
10
20
30
40
50
60
70
80
90
100
0.01 0.1 1 10 100Percent Passing SieveDiameter of Particle in Millimeters
Plot of Gradation Analysis
3"1.5"3/4"3/8"#4#8#30#50#100#200 #16
J:\_WP X4-LKP\_2018\18-3277Fahrney\OSI\18-3277-United5-7-19 to 11-7-19Sand Gradation Analysis Spreadsheet