Loading...
HomeMy WebLinkAbout426 Squires Ln - 210935101002Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970) 328-8730 Fax: (970) 328-7185 Permit Permit No. OWTS-018817-2020 Permit Type: OWTS Permit Work Classification: New Permit Status: Active Issue Date: 6/2/2020 Expires: 9/30/2020 On-Site Wastewater Treatement System Project Address Parcel Number 426 SQUIRES LN, EAGLE AREA,210935101002 Owner Information Address Mark and Deborah Spiers 427 Garfield ST Denver, CO 80206 Phone: (908) 304-2305 Cell: Email: msspiers@gmail.com Inspections: For Inspections Call: (970) 328-8755 and call the Design Engineer Engineer Phone Email JVA Inc, Simon Farrell (303) 444-1951 sfarrell@jvajva.com Contractor License Number Phone Email Permitted Construction / Details: A licensed installer has not been identified. No person shall install, renovate, or repair an OWTS in Eagle County (EC) without a valid EC Systems Contractor License. Any person that conducts a business as a systems contractor without having obtained a valid license section commits a Class 1 petty offense as defined in section 18-1.3-503, C.R.S. Please notify the department when an installer is identified, prior to installation of the OWTS. Install the OWTS exactly as depicted in the JVA, Inc. design stamped, signed and dated April 7, 2020 by Simon A. Farrell, PE. The OWTS is designed with capacity to serve a 5 bedroom residence. The system consists of a Valley Precast 1,250 gallon, single compartment tank with effluent screen and alarm placed on the outlet, followed by a 2,000 gallon Valley Precast three-compartment recirculating/dose tank which will send wastewater to two, Advantex AX 20 pods for nitrification using an Orenco PF 500512 pump. Nitrified effluent flows to the splitter valve for recirculation to the 1,250 gallon first tank for denitrification then is dosed using an Orenco PF 751012 pump to 1728 square feet of soil treatment area via two beds each consisting of four rows of 18 Infiltrator Quick 4 Plus Standard chambers for a total of 144 Infiltrator chambers, set atop two feet of sand filter media that meets a gradiation of prefferred or secondary media as defined in 43.11.C.2. Note: Gradation of the sand media use must be completed within one month prior to the installation and confirmed with the design engineer. If the sand does not conform to secondary or preferred sand media requirements, it cannot be used for the sand treatment media. Distribution lateral details, along with orifice size, spacing and orientation are on the design drawing. The contractor must verify that all electrical components and inspections are covered under the electrical permit associated with the Orenco Vericom control panel (Model VCOM-AX20B2) and pump connections. The alarm must be connected to a separate circuit. Additional pump details are on the design drawing. Advantex systems must conform to the CDPHE technology approval letter dated May 1, 2018. Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections necessary to certify the installation and assure functionality of the system. System certification, along with photos and a record drawing is required to be submitted to, and approved by, Eagle County Environmental Health prior to the use of the system or occupancy of the dwelling. Tuesday, June 2, 2020 1 THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT Issued by: Environmental Health Department, Eagle County, CO Claire Lewandowski Date June 02, 2020 CONDITIONS 1. 2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED 3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED Tuesday, June 2, 2020 2 *************************************************************************** APPLICATION FOR ON-SITE WASTEWATER TREATMENT SYSTEM (OWTS) PERMIT INCOMPLETE APPLICATIONS MAY NOT BE ACCEPTED (SITE PLAN MUST BE INCLUDED) FEE SCHEDULE APPLICATION FEE FOR NEW OWTS OR MAJOR REPAIRS $800.00 MINOR REPAIR FEE $400.00 Fee includes the design review, permitting and maintenance of OWTS records Make all checks payable to: Eagle County Treasurer Property Owner: _______________________________________Phone: ________________________ Owner Mailing Address: ________________________________ email: _________________________ Professional Engineer: __________________________________ Phone: ________________________ Applicant / Contact Person: ______________________________Phone: ________________________ Licensed Systems Contractor Name / Company: ___________________________________________ Contractor Mailing Address: _________________________________ Contractor License #:_______ Contractor Phone Number: ________________________ email: ______________________________ OWTS Permit Application is for: ____ New Installation ____ Alteration ____ Repair Tax Parcel Number: _________________________________ Lot Size: ________________________ Assessor’s Link: www.eaglecounty.us/patie/ Physical Address: _____________________________________________________________________ Legal Description: ____________________________________________________________________ Building Type: _____ Residential / Single Family _____ Residential / Multi Family _____ Commercial / Industrial Number of Bedrooms: ______ Number of Bedrooms: ______ Type of Use: _______________ *As of 06/27/2014, all systems require design by a Registered Professional Engineer. Type of Water Supply: ____ Private Well ____ Spring ____ Surface ____ Public If Public, Name of Supplier: ____________________________________________________________ Applicant Signature: ______________________________________Date:_______________________ **************************************************************************** Office Use Only: OWTS PERMIT # __________________ BUILDING PERMIT # ____________________ Amount Paid: ___________ Receipt #: ___________ Check #: ___________ Date: ______________ DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX: (970) 328-8788 TOLL FREE: 800-225-6136 www.eaglecounty.us P.O. Box 179 500 Broadway Eagle, CO 81631 environment@eaglecounty.us April 8, 2020 Ms. Claire Lewandowski, REHS Eagle County Environmental Health 590 Broadway Eagle, CO 81631 RE: Frost Creek - Onsite Wastewater Treatment System Design – Lot 3, Eagle County, CO Dear Claire: JVA Inc. (JVA) has prepared a design of an onsite wastewater treatment system (OWTS) to serve Lot 3 within the Frost Creek PUD. JVA is the designated engineer to process all OWTS permit applications within Frost Creek. JVA has prepared the OWTS design to be in general conformance with OWTS requirements of the PUD. The 2019 annual Water Quality Monitoring Report prepared by Wright Water Engineers documents exceedances of the 85th percentile background concentrations during sampling events in 2019. The report states the following ‘The trends of water quality parameters seen throughout the sampling of groundwater and surface water at the Frost Creek PUD have not reflected a marked upward increase in concentrations of the sampled parameters. As more homes are constructed on the Frost Creek PUD during 2020, the surface water and groundwater sampling location will continue to be monitored’ Sincerely, JVA, INCORPORATED By: _______________________ Simon Farrell, P.E. Project Manager, Associate Attachment A - OWTS design – Lot 3 Attachment B - Visual and Tactile Soil Evaluation Attachment C - Discharge pump calculations ATTACHMENT A – OWTS DESIGN – LOT 3 ATTACHMENT B – VISUAL AND TACTILE SOIL EVALUATION April 8, 2020 Ms. Claire Lewandowski, REHS Eagle County Environmental Health 590 Broadway Eagle, CO 81631 RE: Frost Creek Lot 3 – Site and Soil Investigation Report for an Onsite Wastewater Treatment System (OWTS) JVA Job No. 1037.9e Dear Claire: Enclosed in this report are the results of the site and soil evaluation for Lot 3’s proposed OWTS located in Frost Creek, Colorado. This report provides information needed to support the design of an OWTS including: results from the preliminary investigation, the site visit, and the soil evaluation. Design calculations are included in the drawing Permit Set attached. PRELIMINARY INVESTIGATION In preparation for a more efficient and informed site visit and soil evaluation, a preliminary investigation was conducted the week of October 1st, 2019. Aerial imagery, and previous Geotechnical investigations were used for the preliminary investigation. Geotechnical investigations were performed by HP Geotech in October 2002 across Frost Creek for OWTS suitability; this geotechnical investigation has been submitted to Eagle County previously. Results from the HP Geotech report showed that Test Hole A and B had a topsoil from zero to six inches deep, then a clay layer to four feet, and a gravel-clay layer from four to eight feet deep. No groundwater was encountered in either test holes. SITE VISIT AND SOIL EVALUATION A site visit and soil evaluation were conducted on October 8th, 2019 by James Cochran; James has passed the CPOW Soils Evaluation Course. The purpose of the site visit and soil evaluation was to confirm hypotheses from the preliminary investigation, identify the topography, landscape position, vegetation, and site constraints for the proposed OWTS, and to conduct a visual and tactile soil evaluation of the underlying soils where the proposed soil treatment area (STA) is to be located for both suitability and sizing. The topography of the site slopes from west to east, and the dominant vegetation consists of native grasses. Site Constraints are shown in the Permit Documents. For the visual and tactile soil evaluation, two soil profile holes were excavated using a tracked excavator. As seen in Table 1 below, Soil Type R-2 was identified as the soil type. No redoximorphic features, indicating seasonally high ground water, were found in either holes. Figures 1 through 4 below show the soil profile holes and corresponding morphology. The proposed STA will be an unlined sand filter with beds. Frost Creek Lot 3 Site and Soil Investigation 4/8/20 2 of 2 Table 1 – Visual and Tactile Soil Results Profile Hole Depth (ft.) Percent Rock Soil Texture Soil Structure Type Soil Structure Grade Soil Type 1 0 – 2 0% retained on 20 mm sieve 5% retained on 2 mm sieve Sandy Loam Blocky Moderate 3 2 – 3 90% retained on 20 mm sieve 10% retained on 2 mm sieve Sandy Loam Blocky Moderate R-2 2 0 – 3 0% retained on 20 mm sieve 5% retained on 2 mm sieve Sandy Loam Blocky Moderate 3 3 – 6 90% retained on 20 mm sieve 10% retained on 2 mm sieve Sandy Loam Blocky Moderate R-2 Figure 1 – Profile Hole One Figure 2 – Profile Hole One Soil Morphology Figure 3 – Profile Hole Two Figure 4 – Profile Hole Two Soil Morphology Sincerely, JVA, INCORPORATED By: _______________________ James Cochran, P.E. Project Engineer ATTACHMENT C – DISCHARGE PUMP CALCULATIONS Pump Selection for a Pressurized System - Single Family Residence Project Frost Creek Lot 3 Parameters Discharge Assembly Size Transport Length Transport Pipe Class Transport Line Size Distributing Valve Model Max Elevation Lift Manifold Length Manifold Pipe Class Manifold Pipe Size Number of Laterals per Cell Lateral Length Lateral Pipe Class Lateral Pipe Size Orifice Size Orifice Spacing Residual Head Flow Meter 'Add-on' Friction Losses 2.00 130 40 2.00 None 7 12 40 1.50 8 78 40 1.50 1/8 3 3.75 None 0 inches feet inches feet feet inches feet inches inches feet feet inches feet Calculations Minimum Flow Rate per Orifice Number of Orifices per Zone Total Flow Rate per Zone Number of Laterals per Zone % Flow Differential 1st/Last Orifice Transport Velocity 0.38 216 81.5 8 2.5 7.8 gpm gpm % fps Frictional Head Losses Loss through Discharge Loss in Transport Loss through Valve Loss in Manifold Loss in Laterals Loss through Flowmeter 'Add-on' Friction Losses 13.3 12.8 0.0 1.1 0.2 0.0 0.0 feet feet feet feet feet feet feet Pipe Volumes Vol of Transport Line Vol of Manifold Vol of Laterals per Zone Total Volume 22.7 1.3 65.9 89.9 gals gals gals gals Minimum Pump Requirements Design Flow Rate Total Dynamic Head 81.5 38.2 gpm feet 0 20 40 60 80 100 0 20 40 60 80 100 Net Discharge (gpm) PumpData PF7515 High Head Effluent Pump 75 GPM, 1-1/2HP 230V 1Ø 60Hz PF7515 High Head Effluent Pump 75 GPM, 1HP 230V 1Ø 60Hz Legend System Curve: Pump Curve: Pump Optimal Range: Operating Point: Design Point: INSPECTION WORKSHEET (EAGLE AREA - 426 SQUIRES - 508451) FOR EAGLE COUNTY GOVERNMENT OWTS-018817-2020Case Number:Case Module:Permit Management 07/08/2021 ApprovedInspection Status:Inspection Date: OWTS Final InspectionInspection Type:Inspector:Claire Lewandowski Job Address:Parcel Number:426 Squires Ln Eagle Area, CO 210935101002 Company Name NameContact Type Contractor Vailterra Construction Abraham Alvarado Engineer JVA Inc Simon Farrell Owner Mark and Deborah Spiers CommentsPassedChecklist Item TrueDosing Chamber/Tank - Dosing Chamber/Tank (when applicable) TrueHigher Level Treatment System - Higher Level Treatment System (when applicable) True Inspected 7/8/2021, 1250 gallon Valley Precast single compartment tank with an effluent screen and alarm placed on the outlet followed by a 2000 gallon Valley Precast three compartment recirculating/dose tank which will send wastewater to two Advantex AX@) pods for nitrification using an Orenco PF 500512 pump. Septic Tank - Septic Tank TrueRecord Drawing - Record Drawing TrueRecord Photos - Record Photos True Received 6/3/2020 from JVA Inc.Site and Soil - Site & Soil True Final Certification provided by JVA, dated October 22, 2021, signed by Simon Farrell, PE. Final Certification Letter - Final Certification Letter True Received 6/3/2020 from JVA Inc.General Plan - General Plan True Inspected 7/8/2021, 2 beds of 4 row rows of 18 chambers for a total of 144. Soil Treatment Area (STA) - Soil Treatment Area (STA) True Vailterra Construction was the licensed installer.Identification of Systems Contractor - Identification of Systems Contractor November 03, 2021 Page 1 of 1P.O. Box 179, 500 Broadway, Eagle, CO 81631-0179 October 22, 2021 Claire Lewandowski, REHS, Environmental Health Specialist III Eagle County Environmental Health 500 Broadway Street Eagle, CO 81631 RE: Onsite Wastewater Treatment System Final Certification – 426 Squires Lane, Lot 3 Dear Claire: The Onsite Wastewater Treatment System (OWTS) covered under Eagle County Permit No. OWTS-018817-2020 was installed by Turnipseed for 426 Squires Lane and is ready for final certification from Eagle County Environmental Health. The engineer of record for this system is Simon Farrell with JVA, Inc (JVA). The final record drawings from JVA, and construction photographs are provided as attachments. As part of the final approval process JVA ensured that start-up was completed by the manufacturer’s representative (Valley Precast, Inc). The system is connected and can be monitored remotely as required in the PUD. Please proceed with the closeout process for this OWTS permit. Sincerely, JVA, INCORPORATED By: ________________________ Simon Farrell, P.E. Associate Enclosure: Attachment A – Record Drawings Attachment B – Construction Photographs CC: Julie Gustavson, JVA ATTACHMENT A – RECORD DRAWINGS FROST CREEK LOT 3 ONSITE WASTEWATER TREATMENT SYSTEM EAGLE COUNTY, COLORADO PERMIT SET APRIL 2020 Set No._______ JVA, Inc.1319 Spruce Street www.jvajva.com Boulder, CO 80302 303.444.1951 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver GENERAL NOTESG0.1 REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY: DRAWN BY: CHECKED BY: JOB #: DATE: © JVA, INC.FROST CREEKLOT 3 OWTSEAGLE, COLORADOSHEET NO. 1037.9e APRIL 2020 SAF JRC JRC JVA, Inc.1319 Spruce Street www.jvajva.com Boulder, CO 80302 303.444.1951 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver CONFORMED TO CONSTRUCTION RECORD 10/2021CLFCLFRECORD DRAWINGS1 CIVIL SITE PLANC1.0 REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY: DRAWN BY: CHECKED BY: JOB #: DATE: © JVA, INC.FROST CREEKLOT 3 OWTSEAGLE, COLORADOSHEET NO. 1037.9e APRIL 2020 SAF JRC JRC JVA, Inc.1319 Spruce Street www.jvajva.com Boulder, CO 80302 303.444.1951 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver CONFORMED TO CONSTRUCTION RECORD 10/2021CLFCLFRECORD DRAWINGS1 TREATMENT SYSTEM AND SITE DETAILSCD1.0 REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY: DRAWN BY: CHECKED BY: JOB #: DATE: © JVA, INC.FROST CREEKLOT 3 OWTSEAGLE, COLORADOSHEET NO. 1037.9e APRIL 2020 SAF JRC JRC JVA, Inc.1319 Spruce Street www.jvajva.com Boulder, CO 80302 303.444.1951 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver CONFORMED TO CONSTRUCTION RECORD 10/2021CLFCLFRECORD DRAWINGS1 SOIL TREATMENT AREA DETAILSCD1.1 REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY: DRAWN BY: CHECKED BY: JOB #: DATE: © JVA, INC.FROST CREEKLOT 3 OWTSEAGLE, COLORADOSHEET NO. 1037.9e APRIL 2020 SAF JRC JRC JVA, Inc.1319 Spruce Street www.jvajva.com Boulder, CO 80302 303.444.1951 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver CONFORMED TO CONSTRUCTION RECORD 10/2021CLFCLFRECORD DRAWINGS1 ATTACHMENT B – CONSTRUCTION PHOTOGRAPHS Lot 3 Sand Gradation Analysis Spreadsheet.xlsx GRADATION ANALYSIS TEST ENTER INFORMATION IN BLUE CELLS LABORATORY TEST REPORT DATA GRADATION RESULTS COMPARED TO PREFERRED AND SECONDARY SAND FILTER SPECIFICATIONS Parameter Value Units Preferred Sand Value Pass / Fail Preferred Sand Secondary Sand Value Pass / Fail Secondary Sand Laboratory United Companies Client: Location / Plant:102_01202-Eagle Sample / Product:14111-Gypsum 1/4" Concrete Sand Sample Date:04/20/2021 - 05/20/2021 Lab Test Date: Job Number: SIEVE SIEVE OPENING IN MILLIMETERS PERCENT PASSING THRU SIEVE 3"75 100.0 1.5 37.5 100.0 3/4"19 100.0 3/8"9.5 99.0 No. 4 4.75 97.0 No. 8 2.36 81.0 No. 16 1.18 63.0 No. 30 0.6 41.0 No. 50 0.3 19.0 No. 100 0.15 6.0 No. 200 0.075 2.3 D60 - Diameter that 60 percent of the sample is finer than.1.10 millimeters Effective Size - D10 - Diameter that 10 percent of the sample is finer than.0.196 millimeters 0.25 to 0.60 0.15 to 0.60 PASS Uniformity Coefficient (D60 / D10)5.61 unitless ratio < or = 4.0 < or = 7.0 PASS Percent passing thru #200 Sieve 2.3 millimeters < or = 3 PASS < or = 3 PASS FAIL FAIL Diameter of Particle in MillimetersPercent Passing Sieve0 10 20 30 40 50 60 70 80 90 100 75 37.5 19 9.5 4.75 2.36 1.18 0.6 0.3 0.15 0.075 Plot of Gradaon Analysis