Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
89 Escalante - 239127302006
Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970) 328-8730 Fax: (970) 328-7185 Permit Permit No. OWTS-021823-2021 Permit Type: OWTS Permit Work Classification: New Permit Status: Active Issue Date: 7/6/2021 Expires: 11/3/2021 On-Site Wastewater Treatement System Project Address Parcel Number 89 ESCALANTE, EL JEBEL AREA,239127302006 Owner Information Address Diane and Hutch Foster 130 S Galena ST Aspen, CO 81611 Phone: (435) 901-0163 Cell: Email: hutchfoster@gmail.com Inspections: For Inspections Call: (970) 328-8755 Engineer Phone Email RB Civil LLC, Romeo Baylosis (970) 471-1103 romeo@rbcivil.com Contractor License Number Phone Email Dennis Brown Excavation dl.brown@live.com(970) 379-8615OWTSPL-000149-20 21 Permitted Construction / Details: Install the OWTS Exactly as depicted in the CBO Septic Consulting design dated April 23, 2021, prepared by Carla Ostberg, stamped, signed, and dated April 27, 2021 by Romeo A. Baylosis. PE. The OWTS is designed to serve a new two bedroom single family residence. The system consists of a 1,000 gallon two-compartment Infiltrator septic tank with an effluent filter in the outlet tee, followed by a distribution box, made accessible at grade, equipped with flow equalizers set to equally distribute effluent between four shallow trenches, each with 14 Quick4 Plus Standard Infiltrator chambers, for a total of 56 chambers. Scarify trench bottoms and sidewalls prior to placement of chambers. Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections necessary to certify the installation and assure the functionality of the system. System certification, along with photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health prior to the use of the system or occupancy of the dwelling. THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT Issued by: Environmental Health Department, Eagle County, CO Claire Lewandowski Date July 06, 2021 CONDITIONS 1. 2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED 3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED Thursday, July 8, 2021 1 INSPECTION WORKSHEET (INSP-516405-2022) FOR EAGLE COUNTY GOVERNMENT OWTS-021823-2021Case Number:Case Module:Permit Management 07/27/2022 ApprovedInspection Status:Inspection Date: OWTS Final InspectionInspection Type:Inspector: Job Address:Parcel Number:89 Escalante El Jebel Area, CO 239127302006 Company Name NameContact Type Contractor Dennis Brown Excavation Dennis Brown Engineer RB Civil LLC Romeo Baylosis Engineer Consultant CBO Septic Consulting Carla Ostberg Owner Diane and Hutch Foster CommentsPassedChecklist Item True 1000-gallon, two-compartment Norwesco® poly septic tank with an Orenco® Effluent Filter on the outlet tee was used. Septic Tank - Septic Tank True Received 7/27/2022 from CBO Inc.Record Drawing - Record Drawing True Received 7/27/2022 from CBO Inc.Record Photos - Record Photos True Received 6/23/2021 from CBO Inc.Site and Soil - Site & Soil True Received 7/27/2022 from CBO Inc.Final Certification Letter - Final Certification Letter True Received 6/23/2021 from CBO Inc.General Plan - General Plan True Each trench consists of 12 ARC ‘ADS’ chambers for a total of 48 chambers and 720 square feet of infiltrative area. Soil Treatment Area (STA) - Soil Treatment Area (STA) True Dennis Brown Excavation was the licensed installer.Identification of Systems Contractor - Identification of Systems Contractor July 27, 2022 Page 1 of 1P.O. Box 179, 500 Broadway, Eagle, CO 81631-0179 CBO Inc. 129 Cains Lane Carbondale, CO 81623 970.309.5259 carla.ostberg@gmail.com July 26, 2022 Project No. C1599 Hutch Foster hutchfoster@gmail.com Onsite Wastewater Treatment System (OWTS) Installation Observations 89 Escalante Eagle County, Colorado Permit Number OWTS-021823-2023 Hutch, CBO Inc. observed the installation of the onsite wastewater treatment system (OWTS) on August 13, 2021 for the subject property. Dennis Brown Excavation installed the system. The OWTS design is based on 3-bedrooms. An average daily wastewater flow of 450 GPD was used. The 4-inch diameter, SDR-35 sewer line exiting the residence has a double-sweep clean out and a minimum 2% grade to the septic tank. The system installation included a 1000-gallon, two-compartment Norwesco® poly septic tank with an Orenco® Effluent Filter on the outlet tee. This filter must be cleaned annually, or as needed. Risers bring the manhole lids to grade for access. Effluent gravity flows to a distribution box, and then to four gravelless chamber trenches. The distribution box was accessible from grade and had flow equalizers installed on each outlet pipe in the distribution box to assure equal flow to each trench. Each trench consists of 12 ARC ‘ADS’ chambers for a total of 48 chambers and 720 square feet of infiltrative area. There was at least 4-feet of undisturbed soil between each trench. Inspection ports were installed at the beginning and end of each trench. Ports may be cut to grade and placed in sprinkler boxes for access. The OWTS was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. CBO Inc. should be notified if changes are made to the OWTS in the future. Any additional OWTS construction must be according to the county regulations. LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. The quality of the installation is dependent on the expertise of the installer, soil type, and weather conditions. 7-26-2022 Please call with questions. Sincerely, CBO Inc. Reviewed By: Carla Ostberg, MPH, REHS Romeo Baylosis, P.E. Clean out near foundation Septic tank after backfill View of septic tank Inlet tee Outlet tee with effluent filter (recommend handle extension) Sewer line from septic tank to distribution box Distribution box Trench with inspection ports installed at beginning and end Undisturbed soil between trenches Verified 100’ from outlet tank lid to Dbox Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970) 328-8730 Fax: (970) 328-7185 Permit Permit No. OWTS-021823-2021 Permit Type: OWTS Permit Work Classification: New Permit Status: Active Issue Date: 7/6/2021 Expires: 11/3/2021 On-Site Wastewater Treatement System Project Address Parcel Number 89 ESCALANTE, EL JEBEL AREA,239127302006 Owner Information Address Diane and Hutch Foster 130 S Galena ST Aspen, CO 81611 Phone: (435) 901-0163 Cell: Email: hutchfoster@gmail.com Inspections: For Inspections Call: (970) 328-8755 and call the Design Engineer Engineer Phone Email RB Civil LLC, Romeo Baylosis (970) 471-1103 romeo@rbcivil.com Contractor License Number Phone Email Permitted Construction / Details: A licensed installer has not been identified. No person shall install, renovate, or repair an OWTS in Eagle County (EC) without a valid EC Systems Contractor License. Any person that conducts a business as a systems contractor without having obtained a valid license section commits a Class 1 petty offense as defined in section 18-1.3-503, C.R.S. Please notify the department when an installer is identified, prior to installation of the OWTS. Install the OWTS Exactly as depicted in the CBO Septic Consulting design dated April 23, 2021, prepared by Carla Ostberg, stamped, signed, and dated April 27, 2021 by Romeo A. Baylosis. PE. The OWTS is designed to serve a new two bedroom single family residence. The system consists of a 1,000 gallon two-compartment Infiltrator septic tank with an effluent filter in the outlet tee, followed by a distribution box, made accessible at grade, equipped with flow equalizers set to equally distribute effluent between four shallow trenches, each with 14 Quick4 Plus Standard Infiltrator chambers, for a total of 56 chambers. Scarify trench bottoms and sidewalls prior to placement of chambers. Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections necessary to certify the installation and assure the functionality of the system. System certification, along with photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health prior to the use of the system or occupancy of the dwelling. THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT Issued by: Environmental Health Department, Eagle County, CO Claire Lewandowski Date July 06, 2021 CONDITIONS 1. 2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED 3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED Tuesday, July 6, 2021 1 89 Escalante Legend 100 ft N➤➤N 832‐R‐13‐002 • Has 5-10 times more flow area than other brands, so lasts many times longer between clean- ings, increasing homeowner satisfaction • Installs in min- utes inside new or existing tanks; extendible tee handle for easy removal • Easy to clean by simply hosing off whenever the tank needs pumping • Removes about two-thirds of sus- pended solids, on average, extending drainfield life • Corrosion-proof construction, to ensure long life • Lifetime warranty Residential Biotube® Effluent Filters Applications Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic tanks and have a lifetime warranty. They prevent large solids from leaving the tank, dramatically improving wastewater quality and extending the life of residential drainfields. Standard Features & Benefits • Alarm available, to signal the need for cleaning • Flow modulating discharge orifices available to limit flow rate leaving tank, mitigat- ing surges and increasing retention time • Custom and commercial sizes available Effluent from the relatively clear zone of the septic tank, between the scum and sludge layers, horizontally enters the Biotube Effluent Filter. Effluent then enters the annular space between the housing and the Biotubes, utilizing the Biotubes’ entire surface for filtering. Particles larger than the Biotube’s mesh are prevented from leaving the tank. Optional Features & Benefits Biotube Filtering Process 8-in. (200-mm) Base Inlet Filter 4-in. (100-mm) Insert Filter 4-in. (100-mm) Biotube Jr. (4-in. Biotube cartridge avail- able separately as Insert Filter) Orenco’s superior effluent filters resist clogging better than all other brands. Our stan- dard, full-sized 4-in. (100-mm) Biotube Effluent Filter provides maximum long-term protection in a complete package, with housing. Our 4-in. (100-mm) Biotube Jr., at half the size of our standard model, has more filtering capacity than the full-sized filters sold by other manufacturers. For tanks with existing outlet tees, the Biotube Insert Filter is ideal. And for low-profile tanks, there’s the Base Inlet Filter. * Covered by patent numbers 5,492,635 and 4,439,323 4-in. (100-mm) Biotube Effluent Filter APS-FT-1 Rev. 3.4 © 11/10 Orenco Systems®, Inc. To Order Call your nearest Orenco Systems®, Inc. distributor. For nearest distribu- tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on “Distributor Locator.” Nomenclatures Riser wall Tank wall Filter housing Extendible PVC handle Stainless steel set screws Top seal plate Air vents Biotube® filter cartridge Solid base 4-in. Biotube Effluent Filter 4-in. Biotube Jr. 4-in. Biotube Filter (standard) 4-in. Biotube Jr. (includes cartridge and housing) Distributed By: 8-in. Biotube Filter (base inlet model) 4-in. Biotube Filter Insert (cartridge only) Junior series FT J0418 Biotube effluent filter series Filter diameter (inches) Cartridge height (inches) W = fits Type 3034 outlet tee S = fits Schedule 40 outlet tee Options: Blank = no options M = flow modulation plate installed A = float bracket attached Blank = 1/8" filtration P = 1/16" filtration Insert FT i0418 Biotube effluent filter series Filter diameter (inches) Cartridge height (inches) W = fits Type 3034 outlet tee S = fits Schedule 40 outlet tee - For customized options (e.g., NC indicates North Carolina regions) - Blank = 1/8" filtration P = 1/16" filtration FT 04 Biotube effluent filter series Filter diameter (inches) Housing height: 36" and 44" are standard Options: Blank = no options M = flow modulation plate installed A = float bracket attached Cartridge height: 28" and 36" are standard - Blank = 1/8" filtration P = 1/16" filtration W = fits Type 3034 outlet pipe S = fits Schedule 40 outlet pipe FT 2208 14 B Biotube effluent filter series Housing height: 22" standard Cartridge height: 14" standard Options: A = float bracket FS = 2" outlet orifice FSO = 2" outlet orifice and overflow plate* Base inlet model - Blank = 1/8" filtration P = 1/16" filtration Filter diameter (inches) 08 = 8" * Also available with coupling and sleeve as a “kit”: FT-OVERFLOWKIT The Quick4® Plus Standard Chamber The Quick4 Plus Standard Chamber offers maximum strength through its two center structural columns. This chamber can be installed in a 36-inch-wide trench. Like the original line of Quick4 chambers, it offers advanced contouring capability with its Contour Swivel Connection™ which permits turns up to 15-degrees, right or left. It is also available in four-foot lengths to provide optimal installation flexibility. The Quick4 Plus All-in-One 12 Endcap, and the Quick4 Periscope are available with this chamber, providing increased flexibility in system configurations. Maximum Strength APPROVED in _____________________________________________ Quick4 Plus™ Series Quick4 Plus All-in-One 12 Endcap Benefits: • May be used at the end of chamber row for an inlet/outlet or can be installed mid-trench • Mid-trench connection feature allows construction of chamber rows with center feed, as an alternative to inletting at the ends of chamber rows • Center-feed connection allows for easy installation of serial distribution systems • Pipe connection options include sides, ends or top Quick4 Plus All-in-One Periscope Benefits: • Allows for raised invert installations • 180° directional inletting • 12” raised invert is ideal for serial applications Certified by the International Association of Plumbing and Mechanical Officials (IAPMO) Quick4 Plus Standard Chamber Specifications Size 34”W x 53”L x 12”H (864 mm x 1346 mm x 305 mm) Effective Length 48” (1219 mm) Louver Height 8” (203 mm) Storage Capacity 47 gal (178 L) Invert Height 0.6” (15 mm), 5.3” (135 mm), 8.0” (203 mm), 12.7” (323 mm) Quick4 Plus Standard Chamber Benefits: • Two center structural columns offer increased stability and superior strength • Advanced contouring connections • Latching mechanism allows for quick installation • Four-foot chamber lengths are easy to handle and install • Supports wheel loads of 16,000 lbs/axle with 12” of cover Contact Infiltrator Water Technologies’ Technical Services Department for assistance at 1-800-221-4436 4 Business Park Road P.O. Box 768 Old Saybrook, CT 06475 860-577-7000 • Fax 860-577-7001 1-800-221-4436 www.infiltratorwater.com U.S. Patents: 4,759,661; 5,017,041; 5,156,488; 5,336,017; 5,401,116; 5,401,459; 5,511,903; 5,716,163; 5,588,778; 5,839,844 Canadian Patents: 1,329,959; 2,004,564 Other patents pending. Infiltrator, Equalizer, Quick4, and SideWinder are registered trademarks of Infiltrator Water Technologies. Infiltrator is a registered trademark in France. Infiltrator Water Technologies is a registered trademark in Mexico. Contour, MicroLeaching, PolyTuff, ChamberSpacer, MultiPort, PosiLock, QuickCut, QuickPlay, SnapLock and StraightLock are trademarks of Infiltrator Water Technologies. PolyLok is a trademark of PolyLok, Inc. TUF-TITE is a registered trademark of TUF-TITE, INC. Ultra-Rib is a trademark of IPEX Inc. © 2013 Infiltrator Water Technologies, LLC. All rights reserved. Printed in U.S.A.PLUS05 0713 Quick4 Plus™ Series INFILTRATOR WATER TECHNOLOGIES STANDARD LIMITED WARRANTY (a) The structural integrity of each chamber, endcap and other accessory manufactured by Infiltrator (“Units”), when installed and operated in a leachfield of an onsite septic system in accordance with Infiltrator’s instructions, is warranted to the original purchaser (“Holder”) against defective materials and workmanship for one year from the date that the septic permit is issued for the septic system containing the Units; provided, however, that if a septic permit is not required by applicable law, the warranty period will begin upon the date that installation of the septic system commences. To exercise its warranty rights, Holder must notify Infiltrator in writing at its Corporate Headquarters in Old Saybrook, Connecticut within fifteen (15) days of the alleged defect. Infiltrator will supply replacement Units for Units determined by Infiltrator to be covered by this Limited Warranty. Infiltrator’s liability specifically excludes the cost of removal and/or installation of the Units. (b) THE LIMITED WARRANTY AND REMEDIES IN SUBPARAGRAPH (a) ARE EXCLUSIVE. THERE ARE NO OTHER WARRANTIES WITH RESPECT TO THE UNITS, INCLUDING NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE (c) This Limited Warranty shall be void if any part of the chamber system is manufactured by anyone other than Infiltrator. The Limited Warranty does not extend to incidental, consequential, special or indirect damages. Infiltrator shall not be liable for penalties or liquidated damages, including loss of production and profits, labor and materials, overhead costs, or other losses or expenses incurred by the Holder or any third party. Specifically excluded from Limited Warranty coverage are damage to the Units due to ordinary wear and tear, alteration, accident, misuse, abuse or neglect of the Units; the Units being subjected to vehicle traffic or other conditions which are not permitted by the installation instructions; failure to maintain the minimum ground covers set forth in the installation instructions; the placement of improper materials into the system containing the Units; failure of the Units or the septic system due to improper siting or improper sizing, excessive water usage, improper grease disposal, or improper operation; or any other event not caused by Infiltrator. This Limited Warranty shall be void if the Holder fails to comply with all of the terms set forth in this Limited Warranty. Further, in no event shall Infiltrator be responsible for any loss or damage to the Holder, the Units, or any third party resulting from installation or shipment, or from any product liability claims of Holder or any third party. For this Limited Warranty to apply, the Units must be installed in accordance with all site conditions required by state and local codes; all other applicable laws; and Infiltrator’s installation instructions. (d) No representative of Infiltrator has the authority to change or extend this Limited Warranty. No warranty applies to any party other than the original Holder. The above represents the Standard Limited Warranty offered by Infiltrator. A limited number of states and counties have different warranty requirements. Any purchaser of Units should contact Infiltrator’s Corporate Headquarters in Old Saybrook, Connecticut, prior to such purchase, to obtain a copy of the applicable warranty, and should carefully read that warranty prior to the purchase of Units. Quick4 Plus Standard Chamber ___________________________________________________________________________________ Quick4 Plus All-in-One 12 Endcap ________________________________________________________________________________ Quick4 Plus All-in-One Periscope ________________________ EFFECTIVE LENGTH48" 12" 34" QUICK4 PLUS ALL-IN-ONE PERISCOPE (360° SWIVEL) 12.7" INVERT PRESSURIZED PIPE DRILL POINTS LOCATIONS (2 PLACES) 33" 18" 8" INVERT 13" EFFECTIVE LENGTH48" 12" 34" QUICK4 PLUS ALL-IN-ONE PERISCOPE (360° SWIVEL) 12.7" INVERT PRESSURIZED PIPE DRILL POINTS LOCATIONS (2 PLACES) 33" 18" 8" INVERT 13" FRONT VIEW SIDE VIEW EFFECTIVE LENGTH48" 12" 34" QUICK4 PLUS ALL-IN-ONE PERISCOPE (360° SWIVEL) 12.7" INVERT PRESSURIZED PIPE DRILL POINTS LOCATIONS (2 PLACES) 33" 18" 8" INVERT 13" 6" 5"9" 33 Four Wheel Drive Road Carbondale, CO 81623 970.309.5259 carla.ostberg@gmail.com April 23, 2021 Project No. C1599 Hutch Foster hutchfoster@gmail.com Subsurface Investigation and Onsite Wastewater Treatment System Design 3-Bedroom Residence 89 Escalante Eagle County, Colorado Hutch, CBO Inc. performed a subsurface investigation and completed an onsite wastewater treatment system (OWTS) design for the subject residence. The property is located outside of Basalt, in an area where OWTSs are necessary. Legal Description: Subdivision: ASPEN MESA EST REFILE 8-13 Block: B Lot: 8 Parcel ID: 2391-273-02-006 SITE CONDITIONS The property is currently undeveloped. A 2-bedroom residence is proposed with a future bedroom contemplated. The residence will be served potable water from a community water system. The water line will enter the property from Escalate to the north and no OWTS component will come within 25-feet of the water line. The property slopes to the south west with an approximate 10% slope. The proposed soil treatment area (STA) is covered with native grasses and is an open field area. There should be no traffic or staging of material over the future STA site to avoid compaction of soils prior to construction of the STA. SUBSURFACE The subsurface was investigated on March 15, 2021 by digging two soil profile test pit excavations (Test Pits). A visual and tactile soil analysis was completed by Carla Ostberg at the time of excavation.1 The materials encountered in Test Pit #1 consisted of dark brown topsoil to 2.0-feet, underlain by light brown calcareous clay matrix to a to a maximum depth explored of 5.0-feet where digging became difficult. No bedrock or groundwater was encountered. The materials encountered in Test Pit #2 consisted of dark brown topsoil to 2.0-feet, underlain by light brown calcareous clay matrix to a maximum depth explored of 6.0-feet where digging become difficult. No bedrock or groundwater was encountered. 1 Carla Ostberg holds a Certificate of Attendance and Examination from the CPOW Visual and Tactile Evaluation of Soils Training. Page 2 A sample of the soil was taken from Test Pit #2 at 3-feet below grade. Soil structure grade was moderate to weak. The soil formed a ball and a ribbon less than 1-inch before breaking. Soil structure shape was blocky and consistence was friable. Soil texture was more smooth than gritty. Soils are consistent with Soil Type 2A. A long term acceptance rate (LTAR) of 0.5 gallons per square foot, will be used to design the OWTS. View of the property from Escalante Test Pit #1 Page 3 Test Pit #1 Backfill Page 4 Test Pit #2 Page 5 Test Pit #2 Backfill Sieved sample Ribbon less than 1-inch before breaking Page 6 DESIGN SPECIFICATIONS Design Calculations: Average Design Flow = 75 GPD x 2 people/bedroom x 3 Bedrooms = 450 GPD LTAR = 0.5 GPD/SF 450 GPD / 0.5 GPD/SF x 1.0 (gravity trenches) x 0.7 (chambers) = 630 SF The new OWTS design is based on 3-bedrooms. An average daily wastewater flow of 450 GPD will be used. For the purposes of this OWTS design, Benchmark Elevation at grade 7224’ (Lower Level Finished Floor) has been established as 100’. CBO Inc. should be notified of any discrepancies or problems with grade elevations of proposed components during installation of the OWTS. OWTS Component Minimum Elevation Primary Tank Inlet Invert Approximate horizontal distance 72’ / min. 2% fall / min. 18” fall Automatic Distributing Valve / Distribution Box Approximate horizontal distance 25’ / min. 1% fall / min. 3.125” fall Infiltrative Surface (to farthest trench) Approximate horizontal distance 14’ / min. 1% fall / min. 1.75” fall *Elevations are based upon standard OWTS installation practices. Component elevations may change during installation due to site conditions. The 4-inch diameter, SDR-35 sewer line exiting the residence must have a double-sweep clean out and a minimum 2% grade to the septic tank. The system installation must include a 1000-gallon, two compartment Infiltrator® poly septic tank with an Orenco® Effluent Filter on the outlet tee. Risers must bring the manhole lids to grade for access. If more than one riser is added to the septic tank, an extension handle must be installed on the effluent filter. Effluent will gravity flow to a distribution box, and then to four gravelless chamber trenches. The distribution box must be accessible from grade and must have flow equalizers, or similar product, installed on each outlet pipe in the distribution box to assure equal flow to each bed. Each trench will consist of 14 ‘Quick 4’ Infiltrator® chambers for a total of 56 chambers and 672 square feet of infiltrative area. There must be at least 4-feet of undisturbed soil between each trench. Inspection ports must be installed at the beginning and end of each trench. Ports may be cut to grade and placed in sprinkler boxes for access. COMPONENT SPECIFICATIONS The component manufacturers are typical of applications used by contractors and engineers in this area. CBO Inc. must approve alternative components prior to installation of the OWTS. Requests must be submitted, in writing, to our office for approval prior to installation. Component technical data sheets are available upon request. Page 7 COMPONENT MANUFACTURER MODEL NO. COMMENTS Septic Tank Infiltrator® IM 1060-2CP Two-compartment poly septic tank Biotube Effluent Filter Orenco® Full Size Effluent Filter and housing Tank Risers and Lids Orenco® Double-walled PVC Risers and Lids (24” diameter) Distribution Box Polylok Poly distribution box, lid, risers, and (4) flow equalizers Chambers Infiltrator® 56 ‘Quick 4’ Chambers Construction must be according to Eagle County On-Site Wastewater Treatment System Regulations, the OWTS Permit provided by Eagle County Environmental Health Department, and this design. INSTALLATION CONTRACTOR CBO Inc. expects that the installer be experienced and qualified to perform the scope of work outlined in this design. The installer must review this design thoroughly and coordinate with our office in advance of installation. Any additional conditions in this design or county permit must be completed and documented prior to final approval of the OWTS installation. Communication between the installer and this office is expected throughout the installation. INSTALLATION OBSERVATIONS CBO Inc. must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. CBO Inc. should be notified 48 hours in advance to observe the installation. In an effort to improve the accuracy of the record drawing, we request that the installer provide a sketch of the installation, including path of the sewer lines, water line installation (if applicable), septic tank location, STA location, and measurements from building corners or another fixed objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design Packet. Photographs of the installation and final cover are also requested to supplement our installation documentation. REVEGETATION REQUIREMENTS An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing characteristics (but without taproots), provides a maximum transpiration rate, and competes well with successional species. No trees or shrubs, or any vegetation requiring regular irrigation shall be placed over the area. Until vegetation is reestablished, erosion and sediment control measures shall be implemented and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation cover. OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. The property owner is responsible for maintaining service contracts for manufactured units, alternating STAs, and any other components needing maintenance. Page 8 4-27-2021 Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during construction of the STA for better weight distribution. Livestock should not graze on the STA. Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA. If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be flushed annually, or as needed. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of freezing. The pump shall have an audible and visual alarm notification in the event of excessively high water conditions and shall be connected to a control breaker separate from the high-water alarm breaker and from any other control system circuits. The pump system shall have a switch so the pump can be manually operated. Extensions should be placed on all septic tank components to allow access to them from existing grade. Backfill over the STA must be uniform and granular with no material greater than minus 3-inch. LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, CBO Inc. should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The contractor should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Licensing of Systems Contractors may be required by county regulation. Please call with questions. Sincerely, CBO Inc. Reviewed By: Carla Ostberg, MPH, REHS Romeo A. Baylosis, PE FOSTER, DIANE 625 E MAIN ST UNIT 102B # 270 ASPEN, CO 81611-2154 Account: R027295 Tax Area: 007 - EL JEBEL (AREA) - 007 Acres: 1.860 Parcel: 2391-273-02-006 Situs Address: 000089 ESCALANTE EL JEBEL AREA, 0 Value Summary Value By:Market Override Land (1)$190,000 N/A Total $190,000 $190,000 Legal Description Subdivision: ASPEN MESA EST REFILE 8-13 Block: B Lot: 8 Sale Data Doc. #Sale Date Deed Type Validity Verified Sale Price Ratio Adj. Price Ratio Time Adj. Price Ratio 202017602 10/02/2020 SWD QV Y $225,000 84.44 $225,000 84.44 $225,000 84.44 201600706 01/18/2016 WD QV Y $230,000 82.61 $230,000 82.61 $230,000 82.61 B: 000667 P: 000919 04/11/1995 WD QV Y $117,000 162.39 $117,000 162.39 $117,000 162.39 B: 0236 P: 0154 08/23/1974 WD N $13,500 1407.41 $13,500 1407.41 $13,500 1407.41 Land Occurrence 1 Abstract Code 0100 - VACANT RES LAND Percentage 100.0 Use Code 1000 - RESIDENTIAL Neighborhood 1010 - OAK RIDGE I Land Code 9057 - FOX RUN MEADOWS Super Neighborhood 900 - BASALT / EL JEBEL AREA Size 1.86 Zoning 1 - R1 SubArea ACTUAL EFFECTIVE HEATED FOOTPRINT Land L 1 Total 1.00 Value Rate Rate Rate Rate $190,000 190,000.00 Property Record Card Eagle County A#: R027295 P#: 239127302006 As of: 04/23/2021 Page 1 of 2 Land Occurrence 1 Abstract Summary Code Classification Actual Value Taxable Value Actual Override Taxable Override 0100 VACANT RES LAND $190,000 $55,100 NA NA Total $190,000 $55,100 NA NA Property Record Card Eagle County A#: R027295 P#: 239127302006 As of: 04/23/2021 Page 2 of 2