Loading...
HomeMy WebLinkAbout554 Escalante - 239127207005Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970) 328-8730 Fax: (970) 328-7185 Permit Permit No. OWTS-021231-2021 Permit Type: OWTS Permit Work Classification: Alteration Permit Status: Active Issue Date: 4/29/2021 Expires: 8/27/2021 On-Site Wastewater Treatement System Project Address Parcel Number 554 ESCALANTE, EL JEBEL AREA,239127207005 Owner Information Address Jacquelyn Lefebvre Phone: Cell: (508) 221-3562 Email: nantucketjuicebar@yahoo.com Inspections: For Inspections Call: (970) 328-8755 and call the Design Engineer Engineer Phone Email RB Civil LLC, Romeo Baylosis (970) 471-1103 romeo@rbcivil.com Contractor License Number Phone Email Zamora Excavating Inc gerryzamora@msn.com(970) 379-7171OWTSPL-000117-20 21 Permitted Construction / Details: Replace the septic tank originally permitted under 0196IS exactly as depicted in the CBO Inc design dated April 21st, 2021, stamped and signed on April 26th, 2021 by Romeo Baylosis PE. The replacement tank is 1,060 gallon two compartment Roth poly septic tank with an effluent filter on the outlet tee. The elevation of the tank placement must align with the existing sewer line exiting the residence and the existing sewer line to the STA. Risers must be added as necessary to bring both access manholes to or above grade. Install a double-sweep clean out as specified on the design drawings between the tank and the house. Replace cast iron sewer pipe as necessary with SDR-35. The old tank is to be abandoned in place as specified in 43.9(C.). Be sure to stake soil treatment area to prevent soil compaction from heavy equipment or tank staging. Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections necessary to certify the installation and assure the functionality of the system. System certification, along with photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health prior to the use of the system. THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT Issued by: Environmental Health Department, Eagle County, CO Danielle Sell Date April 29, 2021 CONDITIONS 1. 2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED 3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED Thursday, April 29, 2021 1 Inspection Result Eagle County, Colorado P.O. Box 179 500 Broadway Eagle, CO Phone: (970) 328-8730 Fax: (970) 328-7185 IVR Phone: 1-866-701-3307 Inspection Number: INSP-525072-2023 Permit Number: OWTS-021231-2021 Inspection Date: 08/31/2023 Inspector: Permit Type: OWTS Permit Inspection Type: OWTS Final Inspection Work Classification: AlterationOwner:Homemade LLC Job Address:554 ESCALANTE IVR Pin Number:192911 EL JEBEL AREA, CO Project:<NONE> Parcel Number:239127207005 Contractor:Phone: (970) 963-1399 / Cell: (970) 379-7171Zamora Excavating Inc Inspection Status: Approved Inspection Notes Inspector Comments Added Item: Septic Tank A new, 1000-gallon, two-compartment Roth® poly septic tank with an Orenco Biotube Effluent filter on the outlet tee was installed. The existing tank was abandoned in place. Added Item: Record Drawing Received 8/31/2023 from CBO Inc. Added Item: Record Photos Received 8/31/2023 from CBO Inc. Added Item: Site and Soil Received 4/27/2021 from CBO Inc. Added Item: Final Certification Letter Received 8/31/2023 from CBO Inc. Added Item: General Plan Received 4/27/2021 from CBO Inc. Added Item: Soil Treatment Area (STA) The existing STA from 1977 remains with no evidence of malfunctioning. Added Item: Identification of Systems Contractor Zamora Excavating was the licensed installer. Thursday, August 31, 2023 For more information visit: http://www.eaglecounty.us Page 1 of 2 Thursday, August 31, 2023 For more information visit: http://www.eaglecounty.us Page 2 of 2 CBO Inc. 129 Cains Lane Carbondale, CO 81623 970.309.5259 carla.ostberg@gmail.com April 3, 2023 Project No. C1600 Jackie Lefebvre nantucketjuicebar@yahoo.com Onsite Wastewater Treatment System (OWTS) Installation Observations 554 Escalante Eagle County, Colorado Permit Number OWTS-021231-2021 Jackie, CBO Inc. observed the installation of the onsite wastewater treatment system (OWTS) in the early summer 2021 and April 3, 2023 for the subject property. Zamora Excavating installed the system. The existing septic tank was pumped, collapsed, and the remaining void filled with onsite material. The original OWTS was sized for 3 bedrooms in 1977. The residence has 3 bedrooms currently. The existing cast iron sewer line was replaced to the house foundation. The 4-inch diameter SDR-35 PVC sewer line had a minimum 2% fall to the septic tank and a double-sweep clean out. A new, 1000-gallon, two-compartment Roth® poly septic tank with an Orenco Biotube Effluent filter on the outlet tee was installed. This filter must be cleaned annually, or as needed. Risers bring the manhole lids to grade. A new 4-inch SDR-35 sewer line was installed from the septic tank and tied into the existing sewer line approximately 15-feet from the new septic tank. The existing STA from 1977 remains with no evidence of malfunctioning. The OWTS was generally installed according to specifications. This observation is not a guarantee of workmanship and/or parts and materials. CBO Inc. should be notified if changes are made to the OWTS in the future. Any additional OWTS construction must be according to the county regulations. LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. The quality of the installation is dependent on the expertise of the installer, soil type, and weather conditions. Please call with questions. Sincerely, CBO Inc. Carla Ostberg, MPH, REHS View of new sewer line and new septic tank / Septic tank bedded in sand Final grading around septic tank View of septic tank lids New sewer line with clean out View of septic tank lids Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970) 328-8730 Fax: (970) 328-7185 Permit Permit No. OWTS-021231-2021 Permit Type: OWTS Permit Work Classification: Alteration Permit Status: Active Issue Date: 4/29/2021 Expires: 8/27/2021 On-Site Wastewater Treatement System Project Address Parcel Number 554 ESCALANTE, EL JEBEL AREA,239127207005 Owner Information Address Jacquelyn Lefebvre Phone: Cell: (508) 221-3562 Email: nantucketjuicebar@yahoo.com Inspections: For Inspections Call: (970) 328-8755 and call the Design Engineer Engineer Phone Email RB Civil LLC, Romeo Baylosis (970) 471-1103 romeo@rbcivil.com Contractor License Number Phone Email Zamora Excavating Inc gerryzamora@msn.com(970) 379-7171OWTSPL-000117-20 21 Permitted Construction / Details: Replace the septic tank originally permitted under 0196IS exactly as depicted in the CBO Inc design dated April 21st, 2021, stamped and signed on April 26th, 2021 by Romeo Baylosis PE. The replacement tank is 1,060 gallon two compartment Roth poly septic tank with an effluent filter on the outlet tee. The elevation of the tank placement must align with the existing sewer line exiting the residence and the existing sewer line to the STA. Risers must be added as necessary to bring both access manholes to or above grade. Install a double-sweep clean out as specified on the design drawings between the tank and the house. Replace cast iron sewer pipe as necessary with SDR-35. The old tank is to be abandoned in place as specified in 43.9(C.). Be sure to stake soil treatment area to prevent soil compaction from heavy equipment or tank staging. Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections necessary to certify the installation and assure the functionality of the system. System certification, along with photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health prior to the use of the system. THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT Issued by: Environmental Health Department, Eagle County, CO Danielle Sell Date April 29, 2021 CONDITIONS 1. 2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED 3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED Thursday, April 29, 2021 1 832‐R‐13‐002 33 Four Wheel Drive Road Carbondale, CO 81623 970.309.5259 carla.ostberg@gmail.com April 21, 2021 Project No. C1600 Jackie Lefebvre nantucketjuicebar@yahoo.com Onsite Wastewater Treatment System Septic Tank Replacement Design 3-Bedroom Residence 554 Escalante Eagle County, Colorado Jackie, CBO Inc. completed an onsite wastewater treatment system (OWTS) septic tank replacement design for the subject residence. The property is located outside of Basalt, in an area where OWTSs are necessary. Legal Description: Subdivision: ASPEN MESA ESTATES FIL 1 LOT:35 Parcel ID: 2391-272-07-005 SITE CONDITIONS A 3-bedroom, single-family residence presently exists and is utilizing an existing OWTS. The OWTS is documented by Eagle County Permit No. 196 which received final approval on August 5, 1977. The OWTS was inspected by Joe Zamora on November 19, 2020 and the septic tank was found to have significant deterioration on the outlet side of the septic tank. There is a desire to replace the septic tank at this time. The residence is served potable water form a community water system. The proposed septic tank will not come within 25-feet of the water line. The existing soil treatment area (STA) appeared to be functioning normally. The intent is to continue to use the existing STA. DESIGN SPECIFICATIONS The existing septic tank will be abandoned in place. The septic tank must be pumped, collapsed, and remaining void filled with gravel, sand, or compacted soil. Design Calculations: 3 bedrooms = min. 1000-gallons septic tank capacity The existing cast iron sewer line must be replaced to the house foundation. The 4-inch diameter SDR-35 PVC sewer line must have a minimum 2% fall to the septic tank and a double-sweep clean out. A new, Roth® poly two-compartment septic tank with an Orenco Biotube Effluent filter on the outlet tee must be installed. Risers must bring the manhole lids to grade. We recommend Orenco® risers and lids. If more than 1-foot of risers are installed, a handle extension must be added to the effluent filter. Page 2 For the purposes of this OWTS design, Benchmark Elevation has been established as 100’ as the sewer line exiting the residence. Elevation of the septic tank placement must align with the existing sewer line exiting the residence and the existing sewer line to the STA. CBO Inc. should be notified of any discrepancies or problems with grade elevations of proposed components during installation of the OWTS. Any cast iron pipe after the septic tank should also be replaced with minimum SDR-35 sewer line with a minimum 1% fall to the existing STA. We recommend testing the STA with approximately 100 gallons of water to assure it is accepting effluent properly. COMPONENT SPECIFICATIONS The component manufacturers are typical of applications used by contractors and engineers in this area. CBO Inc. must approve alternative components prior to installation of the OWTS. Requests must be submitted, in writing, to our office for approval prior to installation. Component technical data sheets are available upon request. COMPONENT MANUFACTURER MODEL NO. COMMENTS Septic Tank Roth Model MRT-1060 2-compartment poly septic tank Tank Risers and Lids Orenco® Double-walled PVC Risers and Lids (24” diameter) Effluent Filter Orenco® Full size effluent filter Construction must be according to Eagle County On-Site Wastewater Treatment System Regulations, the OWTS Permit provided by Eagle County Environmental Health Department, and this design. INSTALLATION CONTRACTOR CBO Inc. expects that the installer be experienced and qualified to perform the scope of work outlined in this design. The installer must review this design thoroughly and coordinate with our office in advance of installation. Any additional conditions in this design or county permit must be completed and documented prior to final approval of the OWTS installation. Communication between the installer and this office is expected throughout the installation. INSTALLATION OBSERVATIONS CBO Inc. must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. CBO Inc. should be notified 48 hours in advance to observe the installation. In an effort to improve the accuracy of the record drawing, we request that the installer provide a sketch of the installation, including path of the sewer lines, water line installation (if applicable), septic tank location, STA location, and measurements from building corners or another fixed objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design Packet. Photographs of the installation and final cover are also requested to supplement our installation documentation. Page 3 4-26-2021 OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. The property owner is responsible for maintaining service contracts for manufactured units, alternating STAs, and any other components needing maintenance. If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be flushed annually, or as needed. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES Extensions should be placed on all septic tank components to allow access to them from existing grade. Backfill over the STA must be uniform and granular with no material greater than minus 3-inch. LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, CBO Inc. should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The contractor should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Licensing of Systems Contractors may be required by county regulation. Please call with questions. Sincerely, CBO Inc. Reviewed By: Carla Ostberg, MPH, REHS Romeo A. Baylosis, PE N SCALE: 1 = 50'=0" \::ilIIi!iIIlIIi[:�:::/1:::t:::.{,;:::�:;-_-,. __ DRAWINGS MUST BE USED IN CONJUNCTION WITH DESIGN LETTER DATED 04/21/2021 @ � i:�::.:,\li�liil!!!!�I[ {!ill11!l(ll�li!!lii)§l!;\e; I ·:,/:,>':>,I ill!!i!I I I 3 BEDROOM I RESIDENCE I EXISTING----...._ SEPTIC TANK TO BE ABANDONED ... APPROX. STA I I I I I I Lot 35 l 1.50 acres as platted (DSITE PLAN 33 Four Wheel Drive Road Carbondale, Colorado 81623 Phone 970.309.5259 carla@allserviceseptic.com 1'=501 -01 WATER Tl SLIP-ON PVC CAP DO NOT GLUE INSULATED COPPER TRACER WIRE 4" DIA SDR-35--� SEWER LINE G STA to REMAIN i i i i i i i i i i i i i i @CLEAN OUT DE��lh-- FINISHED GRADE 4" DIA SDR-35 SEWER LINE (MIN 2% SLOPE TO TANK, MIN.1% TO STA) SCREENED ROCK---- OR SAND FOR --i���� BEDDING 8" MIN. 3" MIN. @lRENCH DETAILllff 16 !l!Ai1 ' =::..:=..:»1111.0'.nn.• ·- Homemade LLC 554 Escalante Eagle County, Colorado Project Number: C1600 Date: 04/21/2021 Designed by: CBO Reviewed by: RB W1.0 Sheet 1 OF 2 • Has 5-10 times more flow area than other brands, so lasts many times longer between clean- ings, increasing homeowner satisfaction • Installs in min- utes inside new or existing tanks; extendible tee handle for easy removal • Easy to clean by simply hosing off whenever the tank needs pumping • Removes about two-thirds of sus- pended solids, on average, extending drainfield life • Corrosion-proof construction, to ensure long life • Lifetime warranty Residential Biotube® Effluent Filters Applications Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic tanks and have a lifetime warranty. They prevent large solids from leaving the tank, dramatically improving wastewater quality and extending the life of residential drainfields. Standard Features & Benefits • Alarm available, to signal the need for cleaning • Flow modulating discharge orifices available to limit flow rate leaving tank, mitigat- ing surges and increasing retention time • Custom and commercial sizes available Effluent from the relatively clear zone of the septic tank, between the scum and sludge layers, horizontally enters the Biotube Effluent Filter. Effluent then enters the annular space between the housing and the Biotubes, utilizing the Biotubes’ entire surface for filtering. Particles larger than the Biotube’s mesh are prevented from leaving the tank. Optional Features & Benefits Biotube Filtering Process 8-in. (200-mm) Base Inlet Filter 4-in. (100-mm) Insert Filter 4-in. (100-mm) Biotube Jr. (4-in. Biotube cartridge avail- able separately as Insert Filter) Orenco’s superior effluent filters resist clogging better than all other brands. Our stan- dard, full-sized 4-in. (100-mm) Biotube Effluent Filter provides maximum long-term protection in a complete package, with housing. Our 4-in. (100-mm) Biotube Jr., at half the size of our standard model, has more filtering capacity than the full-sized filters sold by other manufacturers. For tanks with existing outlet tees, the Biotube Insert Filter is ideal. And for low-profile tanks, there’s the Base Inlet Filter. * Covered by patent numbers 5,492,635 and 4,439,323 4-in. (100-mm) Biotube Effluent Filter APS-FT-1 Rev. 3.4 © 11/10 Orenco Systems®, Inc. To Order Call your nearest Orenco Systems®, Inc. distributor. For nearest distribu- tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on “Distributor Locator.” Nomenclatures Riser wall Tank wall Filter housing Extendible PVC handle Stainless steel set screws Top seal plate Air vents Biotube® filter cartridge Solid base 4-in. Biotube Effluent Filter 4-in. Biotube Jr. 4-in. Biotube Filter (standard) 4-in. Biotube Jr. (includes cartridge and housing) Distributed By: 8-in. Biotube Filter (base inlet model) 4-in. Biotube Filter Insert (cartridge only) Junior series FT J0418 Biotube effluent filter series Filter diameter (inches) Cartridge height (inches) W = fits Type 3034 outlet tee S = fits Schedule 40 outlet tee Options: Blank = no options M = flow modulation plate installed A = float bracket attached Blank = 1/8" filtration P = 1/16" filtration Insert FT i0418 Biotube effluent filter series Filter diameter (inches) Cartridge height (inches) W = fits Type 3034 outlet tee S = fits Schedule 40 outlet tee - For customized options (e.g., NC indicates North Carolina regions) - Blank = 1/8" filtration P = 1/16" filtration FT 04 Biotube effluent filter series Filter diameter (inches) Housing height: 36" and 44" are standard Options: Blank = no options M = flow modulation plate installed A = float bracket attached Cartridge height: 28" and 36" are standard - Blank = 1/8" filtration P = 1/16" filtration W = fits Type 3034 outlet pipe S = fits Schedule 40 outlet pipe FT 2208 14 B Biotube effluent filter series Housing height: 22" standard Cartridge height: 14" standard Options: A = float bracket FS = 2" outlet orifice FSO = 2" outlet orifice and overflow plate* Base inlet model - Blank = 1/8" filtration P = 1/16" filtration Filter diameter (inches) 08 = 8" * Also available with coupling and sleeve as a “kit”: FT-OVERFLOWKIT 554 Escalante W rite a des c ription for your m ap. Legend 554 Es c alante Rd 200 ft N➤➤N HOMEMADE LLC 26 LOVERS LN NANTUCKET, MA 02554-2842 Account: R031608 Tax Area: 007 - EL JEBEL (AREA) - 007 Acres: 1.500 Parcel: 2391-272-07-005 Situs Address: 000554 ESCALANTE EL JEBEL AREA, 0 Value Summary Value By:Market Override Land (1)$190,000 N/A Single Family Residence (1) $658,970 N/A Extra Feature (1)$3,520 N/A Total $852,490 $852,490 Legal Description Subdivision: ASPEN MESA ESTATES FIL 1 Lot: 35 Sale Data Doc. #Sale Date Deed Type Validity Verified Sale Price Ratio Adj. Price Ratio Time Adj. Price Ratio 202025674 12/22/2020 SWD N $842,000 101.25 $842,000 101.25 $842,000 101.25 B: 000693 P: 000374 04/15/1996 WD QV Y $450,000 189.44 $450,000 189.44 $450,000 189.44 Land Occurrence 1 Abstract Code 1112 - SINGLE FAM.RES.-LAND Percentage 100.0 Use Code 1000 - RESIDENTIAL Neighborhood 1010 - OAK RIDGE I Land Code 9057 - FOX RUN MEADOWS Super Neighborhood 900 - BASALT / EL JEBEL AREA Size 1.5 SubArea ACTUAL EFFECTIVE HEATED FOOTPRINT Land L 1 Total 1.00 Value Rate Rate Rate Rate Property Record Card Eagle County A#: R031608 P#: 239127207005 As of: 04/25/2021 Page 1 of 3 Land Occurrence 1 $190,000 190,000.00 Single Family Residence Occurrence 1 Abstract Code 1212 - SINGLE FAM.RES- IMPROVEMTS Percentage 100.0 Use Code 1000 - RESIDENTIAL Neighborhood 1010 - OAK RIDGE I Building Type 121200 - SFR Arch Style 3 - 2 STORY Exterior Wall 16 - FR STUCCO Percentage 100.0 Roof Cover 5 - METAL Roof Structure 2 - SHED Interior Wall 5 - DRYWALL Percentage 100.0 Floor 12 - HARDWOOD 14 - CARPET INV Percentage 20.0 80.0 Heating Fuel 3 - GAS Heating Type 3 - FORCED AIR Air Conditioning 1 - NONE Actual Year Built 1977 Bedrooms 3 Bathrooms 3 Construction Quality 3 - FAIR Effective Year Built 2000 Fixtures 13 Rooms 8 Units 1 Units 1 Super Neighborhood 900 - BASALT / EL JEBEL AREA Stories 3 - STORIES 3.0 Use Code 1000 - RESIDENTIAL Garage 4 - GARAGE 1101-1250 SubArea ACTUAL EFFECTIVE HEATED FOOTPRINT BAS 1428.0 1428.0 1428.0 1428.0 FBM 1428.0 1142.4 1428.0 1428.0 FOP 298.0 89.4 298.0 FUS 357.0 357.0 357.0 357.0 GDF 1200.0 1200.0 PTO 420.0 42.0 420.0 UDU 551.0 220.4 551.0 WDD 699.9 140.0 699.9 Total 6,381.90 3,419.20 3,213.00 6,381.90 Value Rate Rate Rate Rate $658,970 103.26 192.73 205.09 103.26 Property Record Card Eagle County A#: R031608 P#: 239127207005 As of: 04/25/2021 Page 2 of 3 Single Family Residence Occurrence 1 Sketch by Apex IV™24.0'50.0'24.0'50.0' GDF 1200.0 ft²29.0'19.0'29.0'19.0' UDU 551.0 ft²17.0'21.0'17.0'21.0' FUS 357.0 ft²21.0'14.0'17.0'21.0'17.0'14.0'21.0'14.0'2.0'21.0'2.0'14.0' FBM 1428.0 ft²8.0'21.0'8.0'FOP 168.0 ft²20.0'21.0'20.0'21.0' PTO 420.0 ft²21.0'14.0'17.0'21.0'17.0'14.0'21.0'14.0'2.0'21.0'2.0'14.0' BAS 1428.0 ft² 5.0'26.0'5.0'FOP130.0 ft²17.0'7.0' 1 0 . 6 ' 21.0'10.6'7.0'17.0'WDD 699.9 ft² Extra Feature Occurrence 1 XFOB Code 110 - FIREPL. A.Abstract Code 1212 - SINGLE FAM.RES- IMPROVEMTS Percentage 100.0 Use Code 1000 - RESIDENTIAL Neighborhood 1010 - OAK RIDGE I Building Number 1 SubArea ACTUAL EFFECTIVE HEATED FOOTPRINT XFOB Units 1 Total 1.00 Value Rate Rate Rate Rate $3,520 3,520.00 Abstract Summary Code Classification Actual Value Taxable Value Actual Override Taxable Override 1112 SINGLE FAM.RES.-LAND $190,000 $13,590 NA NA 1212 SINGLE FAM.RES-IMPROVEMTS $662,490 $47,370 NA NA Total $852,490 $60,960 NA NA Property Record Card Eagle County A#: R031608 P#: 239127207005 As of: 04/25/2021 Page 3 of 3