HomeMy WebLinkAbout1849 Upper Cattle Creek Rd - 239127300001Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970) 328-8730
Fax: (970) 328-7185
Permit
Permit No. OWTS-020777-2021
Permit Type: OWTS Permit
Work Classification: Major Repair
Permit Status: Active
Issue Date: 3/18/2021 Expires: 7/16/2021
On-Site Wastewater
Treatement System
Project Address Parcel Number
1849 UPPER CATTLE CREEK RD, EL JEBEL AREA,239127300001
Owner Information Address
Carole Inglis 1849 UPPER CATTLE CREEK RD
EL JEBEL AREA, CO
Phone:
Cell: (970) 618-7674
Email: caroleinglis@gmail.com
Inspections:
For Inspections Call: (970) 328-8755
and call the Design Engineer
Engineer Phone Email
RB Civil LLC, Romeo Baylosis (970) 471-1103 romeo@rbcivil.com
Contractor License Number Phone Email
Dirt Devil Excavation Inc.dirtdevilexc@gmail.com(970) 274-1533
Permitted Construction / Details:
This system is designed to replace the existing failing septic system. Replace the existing system, originally
installed in the year 1969, exactly as depicted in the CBO Septic Consulting design stamped and signed on October
28th, 2020 by Romeo Baylosis and dated on October 17th, 2020. The new system will be sized to accommodate the
maximum daily flows for a 3 bedroom residence with the future addition of 2 bedroom Auxiliary Dwelling Unit (ADU).
At the time of submitting for the ADU building permit application, an alteration permit must be obtained for the
connection of the ADU to this OWTS .
This OWTS consists of one new sewer line from the residence. An Infiltrator 1,500 gallon, two-compartment poly
septic tank shall be used with an effluent filter in the outlet tee. A Valley Precast distribution box with 7 flow
equalizers will be used, and must be set level upon compacted gravel, and made accessible at grade. The STA
consists of 7 shallow trenches with 11 Infiltrator Quick 4 Plus Standard chambers for a total of 77. The existing
septic tank should be abandoned per ECPHE OWTS Regulations #43.9.C.
A licensed installer has not been identified. No person shall install, renovate, or repair an OWTS in Eagle County
(EC) without a valid EC Systems Contractor License. Any person that conducts a business as a systems contractor
without having obtained a valid license section commits a Class 1 petty offense as defined in section 18-1.3-503,
C.R.S. Please notify the department when an installer is identified, prior to installation of the OWTS.
Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior
to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections
necessary to certify the installation and assure the functionality of the system. System certification, along with
photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health
prior to the use of the system.
THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF
ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
Issued by: Environmental Health Department, Eagle County, CO
Danielle Sell
Date
March 18, 2021
CONDITIONS
1.
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS,
ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Thursday, March 18, 2021 1
***************************************************************************
APPLICATION FOR ON-SITE WASTEWATER TREATMENT SYSTEM (OWTS) PERMIT
INCOMPLETE APPLICATIONS MAY NOT BE ACCEPTED (SITE PLAN MUST BE INCLUDED)
FEE SCHEDULE
APPLICATION FEE FOR NEW OWTS OR MAJOR REPAIRS $800.00 MINOR REPAIR FEE $400.00
Fee includes the design review, permitting and maintenance of OWTS records
Make all checks payable to: Eagle County Treasurer
Property Owner: _______________________________________Phone: ________________________
Owner Mailing Address: ________________________________ email: _________________________
Professional Engineer: __________________________________ Phone: ________________________
Applicant / Contact Person: ______________________________Phone: ________________________
Licensed Systems Contractor Name / Company: ___________________________________________
Contractor Mailing Address: _________________________________ Contractor License #:_______
Contractor Phone Number: ________________________ email: ______________________________
OWTS Permit Application is for: ____ New Installation ____ Alteration ____ Repair
Tax Parcel Number: _________________________________ Lot Size: ________________________
Assessor’s Link: www.eaglecounty.us/patie/
Physical Address: _____________________________________________________________________
Legal Description: ____________________________________________________________________
Building Type: _____ Residential / Single Family
_____ Residential / Multi Family
_____ Commercial / Industrial
Number of Bedrooms: ______
Number of Bedrooms: ______
Type of Use: _______________
*As of 06/27/2014, all systems require design by a Registered Professional Engineer.
Type of Water Supply: ____ Private Well ____ Spring ____ Surface ____ Public
If Public, Name of Supplier: ____________________________________________________________
Applicant Signature: ______________________________________Date:_______________________
****************************************************************************
Office Use Only: OWTS PERMIT # __________________ BUILDING PERMIT # ____________________
Amount Paid: ___________ Receipt #: ___________ Check #: ___________ Date: ______________
DEPARTMENT OF
ENVIRONMENTAL HEALTH
(970) 328-8755
FAX: (970) 328-8788
TOLL FREE: 800-225-6136
www.eaglecounty.us
P.O. Box 179
500 Broadway
Eagle, CO 81631
environment@eaglecounty.us
Matthew & Carole Inglis 970-618-7674
1849 Upper Cattle Creek Road, Carbondale, CO, 81623caroleinglis@gmail.com
Carla Ostberg 970-309-5259
carole inglis 970-618-7674
Keith McClaren; Dirt Devil Excavation
PO Box 759, carbondale, co, 81623
970-274-1533 dirtdevilexc@gmail.com
4
2391-273-00-001 4.28 acres
1849 Upper Cattle Creek Road, Carbondale, CO, 81623
section 27 township 7 range 87 PCLIN SE1/4SW1/4 BK-0203 PG-0091 WDBK-0471 PG-0450 SWD09-26-87 R915310 DC 12-04-87 R915314 DEC 05-11-05
4
3/15/21
Inspection Result
Eagle County, Colorado
P.O. Box 179 500 Broadway Eagle, CO
Phone: (970) 328-8730 Fax: (970) 328-7185
IVR Phone: 1-866-701-3307
Inspection Number: INSP-517033-2022 Permit Number: OWTS-020777-2021
Inspection Date: 08/24/2022
Inspector:
Permit Type: OWTS Permit
Inspection Type: OWTS Final Inspection
Work Classification: Major RepairOwner:Carole and Matthew Inglis
Job Address:1849 UPPER CATTLE CREEK RD IVR Pin Number:192440
EL JEBEL AREA, CO Project:<NONE>
Parcel Number:239127300001
Contractor:Phone: (970) 274-1533 / Cell: Dirt Devil Excavation Inc.
Inspection Status: Approved
Inspection Notes
Inspector Comments
Added Item: Septic Tank
A 1500-gallon, two-compartment poly Infiltrator septic tank with an effluent filter on the outlet tee was
used.
Added Item: Record Drawing
Received 8/23/2022 from CBO Inc.
Added Item: Record Photos
Received 8/23/2022 from CBO Inc.
Added Item: Site and Soil
Received 3/18/2021 from CBO Inc.
Added Item: Final Certification Letter
Received 8/23/2022 from CBO Inc.
Added Item: General Plan
Received 3/18/2021 from CBO Inc.
Added Item: Soil Treatment Area (STA)
The STA consists of 7 shallow trenches with 11 Infiltrator Quick 4 Plus Standard chambers for a total of
77.
Added Item: Identification of Systems Contractor
Dirt Devil Excavation was the licensed installer.
Wednesday, August 24, 2022
For more information visit: http://www.eaglecounty.us
Page 1 of 2
Wednesday, August 24, 2022
For more information visit: http://www.eaglecounty.us
Page 2 of 2
129 Cains lane
Carbondale, CO 81623
970.309.5259
carla.ostberg@gmail.com
August 19, 2022 Project No. C1552
Carole Inglis
caroleinglis@gmail.com
Onsite Wastewater Treatment System (OWTS) Installation Observations
1849 Upper Cattle Creek Road
Eagle County, Colorado
Permit Number OWTS-020777-2021
Carole,
CBO Inc. observed the installation of the onsite wastewater treatment system (OWTS) on May 13, 2021
for the subject property. Dirt Devil Excavation installed the system.
The new OWTS design is based on 3-bedrooms plus a future 2-bedroom ADU for a total of 5 bedrooms.
An average daily wastewater flow of 750 GPD will be used.
The existing septic tank was pumped and removed.
The system installation included a 1500-gallon, two-compartment poly Infiltrator® septic tank with an
effluent filter on the outlet tee. This filter must be cleaned annually, or as needed. Risers bring the
manhole lids to grade for access.
Effluent gravity flows to a distribution box, and then to seven gravelless chamber trenches. The
distribution box was accessible from grade and flow equalizers were installed on each outlet pipe in the
distribution box to assure equal flow to each trench.
Each trench consisted of 11 ‘Quick 4’ Standard Plus Infiltrator® chambers for a total of 924 square feet of
infiltrative area. There was at least 4-feet of undisturbed soil between each trench. Inspection ports
were installed at the beginning and end of each trench. Ports may be cut to grade and placed in sprinkler
boxes for access.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. CBO Inc. should be notified if changes are made to the OWTS
in the future. Any additional OWTS construction must be according to the county regulations.
LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent of the expertise of the installer, soil
type, and weather conditions.
8-22-2022
Please call with questions.
Sincerely,
CBO Inc. Reviewed By:
Carla Ostberg, MPH, REHS Romeo Baylosis, P.E.
Sewer line from house Septic tank installation
Effluent filter
Sewer line to distribution box Distribution box
Piping from distribution box Inspection port
Distribution lines to trenches Distribution box
Trench
Inspection ports at end of trenches
Tank after backfill
Distribution box
STA backfilled Cleanouts
Existing metal tank abandoned / removed
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
Phone: (970) 328-8730
Fax: (970) 328-7185
Permit
Permit No. OWTS-020777-2021
Permit Type: OWTS Permit
Work Classification: Major Repair
Permit Status: Active
Issue Date: 3/18/2021 Expires: 7/16/2021
On-Site Wastewater
Treatement System
Project Address Parcel Number
1849 UPPER CATTLE CREEK RD, EL JEBEL AREA,239127300001
Owner Information Address
Carole Inglis 1849 UPPER CATTLE CREEK RD
EL JEBEL AREA, CO
Phone:
Cell: (970) 618-7674
Email: caroleinglis@gmail.com
Inspections:
For Inspections Call: (970) 328-8755
and call the Design Engineer
Engineer Phone Email
RB Civil LLC, Romeo Baylosis (970) 471-1103 romeo@rbcivil.com
Contractor License Number Phone Email
Dirt Devil Excavation Inc.dirtdevilexc@gmail.com(970) 274-1533
Permitted Construction / Details:
This system is designed to replace the existing failing septic system. Replace the existing system, originally
installed in the year 1969, exactly as depicted in the CBO Septic Consulting design stamped and signed on October
28th, 2020 by Romeo Baylosis and dated on October 17th, 2020. The new system will be sized to accommodate the
maximum daily flows for a 3 bedroom residence with the future addition of 2 bedroom Auxiliary Dwelling Unit (ADU).
At the time of submitting for the ADU building permit application, an alteration permit must be obtained for the
connection of the ADU to this OWTS .
This OWTS consists of one new sewer line from the residence. An Infiltrator 1,500 gallon, two-compartment poly
septic tank shall be used with an effluent filter in the outlet tee. A Valley Precast distribution box with 7 flow
equalizers will be used, and must be set level upon compacted gravel, and made accessible at grade. The STA
consists of 7 shallow trenches with 11 Infiltrator Quick 4 Plus Standard chambers for a total of 77. The existing
septic tank should be abandoned per ECPHE OWTS Regulations #43.9.C.
A licensed installer has not been identified. No person shall install, renovate, or repair an OWTS in Eagle County
(EC) without a valid EC Systems Contractor License. Any person that conducts a business as a systems contractor
without having obtained a valid license section commits a Class 1 petty offense as defined in section 18-1.3-503,
C.R.S. Please notify the department when an installer is identified, prior to installation of the OWTS.
Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior
to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections
necessary to certify the installation and assure the functionality of the system. System certification, along with
photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health
prior to the use of the system.
THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF
ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
Issued by: Environmental Health Department, Eagle County, CO
Danielle Sell
Date
March 18, 2021
CONDITIONS
1.
2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS,
ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Thursday, March 18, 2021 1
832‐R‐13‐002
33 Four Wheel Drive Road
Carbondale, CO 81623
970.309.5259
carla.ostberg@gmail.com
October 17, 2020 Project No. C1552
Carole Inglis
caroleinglis@gmail.com
Subsurface Investigation and Onsite Wastewater Treatment System Design
3 Bedroom Residence + 2-bedroom Future ADU
1849 Upper Cattle Creek Road
Eagle County, Colorado
Carole,
CBO Inc. performed a subsurface investigation and completed an onsite wastewater treatment system
(OWTS) design for the subject residence. The property is located outside of Basalt, in an area where
OWTSs and wells are necessary.
Legal Description: Section: 27 Township: 7 Range: 87 PCLIN SE1/4SW1/4
BK-0203 PG-0091 WD
BK-0471 PG-0450 SWD 09-26-87
R915310 DC 12-04-87
R915314 DEC 05-11-05
Parcel ID: 2391-273-00-001
SITE CONDITIONS A 3-bedroom, single-family residence presently exists and is utilizing an existing OWTS. The existing
OWTS is aging and original to the house (1969). A new, 2-bedroom additional dwelling unit (ADU) is
also proposed.
The residence is served by a shared well that is located on the neighboring property to the east. The well
is greater than 50-feet from the proposed septic tank and greater than 100-feet from the proposed soil
treatment area (STA).
There is a transition between the yard area and native vegetation to the west. The STA will begin to the
west of the yard.
The proposed STA is in the native vegetation on the property, to the west of the yard. The area slopes to
the south with an approximate 20% slope. The western property boundary has been staked by a
surveyor and a minimum 10-foot setback from the property line will be maintained.
There should be no traffic or staging of material over the future STA site to avoid compaction of soils
prior to construction of the STA.
Page 2
SUBSURFACE The subsurface was investigated on August 18, 2020 by digging three soil profile test pit excavations (Test
Pits). Visual and tactile soil analysis was completed by Carla Ostberg at the time of excavation.1
The materials encountered in the Test Pit #1 consisted of dark brown topsoil to 1.5-feet, underlain by tan
calcareous clay matrix to a maximum depth explored of 6.5-feet. No bedrock or groundwater was
encountered.
The materials encountered in the Test Pit #2 consisted of dark brown topsoil to 0.5-feet, underlain by tan
calcareous clay matrix to a maximum depth explored of 6.5-feet. No bedrock or groundwater was
encountered.
The materials encountered in the Test Pit #3 consisted of dark brown topsoil to 1.0-feet, underlain by tan
calcareous clay matrix to a maximum depth explored of 7.0-feet. No bedrock or groundwater was
encountered.
Soils encountered are consistent with Soil Type 2. A long term acceptance rate (LTAR) of 0.6 gallons
per square foot will be used to design the OWTS.
Test Pit #1 Backfill
1 Carla Ostberg holds a Certificate of Attendance and Examination from the CPOW Visual and Tactile
Evaluation of Soils Training.
Page 3
Sieved sample Ribbon less than 1” / peds
Test Pit #2 View of test pits
Page 4
Test Pit #3
DESIGN SPECIFICATIONS
The existing septic tank will be pumped, crushed, and remaining void filled with onsite material or
removed. The existing STA will be abandoned in place.
Design Calculations:
Average Design Flow Main House = 75 GPD x 2 people/bedroom x 3 Bedrooms = 450 GPD
Average Design Flow Future ADU = 75 GPD x 2 people/bedroom x 2 Bedrooms = 300 GPD
Average Design Flow = 750 GPD
LTAR = 0.6 GPD/SF
750 GPD / 0.6 GPD/SF x 1.0 (gravity trenches) x 0.7 (chambers) = 875 SF
The OWTS design is based on 5 total bedrooms. An average daily wastewater flow of 750 GPD will be
used.
For the purposes of this OWTS design, Benchmark Elevation has been established as 100’ as the sewer
line existing the residence. CBO Inc. should be notified of any discrepancies or problems with grade
elevations of proposed components during installation of the OWTS.
OWTS Component Minimum Elevation
Primary Tank Inlet Invert Approx. horizontal distance 23’ / min. 2% fall to
septic tank / min. 5.75” fall
Distribution Box Approx. horizontal distance 35’ / min. 1% fall to
distribution box / min. 4.375” fall
Infiltrative Surface (upper trench) Approx. horizontal distance to upper trench 14’ /
min. 1% fall / min. 1.75” fall
Page 5
A new 4-inch SDR-35 sewer line must be installed with a double-sweep clean out and minimum 2% fall to
the septic tank.
The system installation must include a 1500-gallon, two-compartment poly Infiltrator® septic tank with an
effluent filter on the outlet tee. Risers must bring the manhole lids to grade for access. If more than one
riser is added to the septic tank, an extension handle must be installed on the effluent filter.
Effluent will gravity flow to a distribution box, and then to seven gravelless chamber trenches. The
distribution box must be accessible from grade and must have flow equalizers, or similar product,
installed on each outlet pipe in the distribution box to assure equal flow to each bed.
Each trench will consist of 11 ‘Quick 4’ Standard Plus Infiltrator® chambers for a total of 924 square feet
of infiltrative area. There must be at least 4-feet of undisturbed soil between each trench, although we
recommend 6-feet separation where feasible. Inspection ports must be installed at the beginning and
end of each trench. Ports may be cut to grade and placed in sprinkler boxes for access.
COMPONENT SPECIFICATIONS
The component manufacturers are typical of applications used by contractors and engineers in this area.
CBO Inc. must approve alternative components prior to installation of the OWTS. Requests must
be submitted, in writing, to our office for approval prior to installation. Component technical data
sheets are available upon request.
COMPONENT MANUFACTURER MODEL NO. COMMENTS
Septic Tank Infiltrator® IM-1530-2CP 1500-gallon, 2-
compartment poly septic
tank Biotube Effluent Filter Orenco® Full Size Effluent Filter and housing
Tank Risers and Lids Orenco® Double-walled PVC Risers and Lids (24” diameter)
Distribution Box Valley Precast D-Box 8C Concrete distribution box Flow Equalizers 3049 Equalizer 7 Flow Equalizers
Chambers Infiltrator® Standard Plus 77 ‘Quick 4’ Chambers
Alternatives may be considered or recommended by contacting our office. Construction must be
according to Eagle County On-Site Wastewater Treatment System Regulations, the OWTS Permit provided
by Eagle County Environmental Health Department, and this design.
INSTALLATION CONTRACTOR
CBO Inc. expects that the installer be experienced and qualified to perform the scope of work outlined in this
design. The installer must review this design thoroughly and coordinate with our office in advance of
installation. Any additional conditions in this design or county permit must be completed and documented
prior to final approval of the OWTS installation. Communication between the installer and this office is
expected throughout the installation.
INSTALLATION OBSERVATIONS CBO Inc. must view the OWTS during construction. The OWTS observation should be performed before
backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing
siphons, and other plumbing, as applicable, must also be observed. CBO Inc. should be notified 48 hours
in advance to observe the installation.
Page 6
In an effort to improve the accuracy of the record drawing, we request that the installer provide a
sketch of the installation, including path of the sewer lines, water line installation (if applicable),
septic tank location, STA location, and measurements from building corners or another fixed
objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design
Packet. Photographs of the installation and final cover are also requested to supplement our installation
documentation.
REVEGETATION REQUIREMENTS
An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire
disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well with
successional species. No trees or shrubs, or any vegetation requiring regular irrigation shall be placed over
the area. Until vegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation
cover.
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the operation and maintenance of each OWTS servicing the
property. The property owner is responsible for maintaining service contracts for manufactured units,
alternating STAs, and any other components needing maintenance.
Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials
should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during
construction of the STA for better weight distribution. Livestock should not graze on the STA. Plumbing
fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a
running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned
annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be
flushed annually, or as needed.
The homeowner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not
be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste
only.
ADDITIONAL CONSTRUCTION NOTES If design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of
freezing. The pump shall have an audible and visual alarm notification in the event of excessively high
water conditions and shall be connected to a control breaker separate from the high-water alarm breaker
and from any other control system circuits. The pump system shall have a switch so the pump can be
manually operated.
Extensions should be placed on all septic tank components to allow access to them from existing grade.
Backfill over the STA must be uniform and granular with no material greater than minus 3-inch.
Page 7
10-28-2020
LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions
described in report, CBO Inc. should be notified. All OWTS construction must be according to the county
regulations. Requirements not specified in this report must follow applicable county regulations. The
contractor should have documented and demonstrated knowledge of the requirements and regulations of
the county in which they are working. Licensing of Systems Contractors may be required by county
regulation.
Please call with questions.
Sincerely,
CBO Inc. Reviewed By:
Carla Ostberg, MPH, REHS Romeo A. Baylosis, PE
1849 Upper Cattle Creek Road Legend
Eddie Ln
100 ft
N➤➤N
INGLIS, MATTHEW C. &
CAROLE A.
1849 UPPER CATTLE CREEK RD
CARBONDALE, CO 81623-9745
Account: R027960
Tax Area: 007 - EL JEBEL (AREA) -
007
Acres: 4.280
Parcel: 2391-273-00-001
Situs Address:
001849 EL JEBEL RD
EL JEBEL AREA, 0
Value Summary
Value By:Market Override
Land (1)$209,000 N/A
Single Family
Residence (1)
$421,840 N/A
Extra Feature (1)$1,290 N/A
Total $632,130 $632,130
Legal Description
Section: 27 Township: 7 Range: 87 PCLIN SE1/4SW1/4
BK-0203 PG-0091 WD
BK-0471 PG-0450 SWD 09-26-87
R915310 DC 12-04-87
R915314 DEC 05-11-05
Sale Data
Doc. #Sale Date Deed Type Validity Verified Sale Price Ratio Adj. Price Ratio Time Adj.
Price
Ratio
201122463 11/29/2011 WD QV Y $484,300 130.52 $481,800 131.20 $481,800 131.20
915311 04/29/2005 WD QV Y $430,000 147.01 $429,800 147.08 $429,800 147.08
Land Occurrence 1
Abstract Code 1112 - SINGLE FAM.RES.-LAND Percentage 100.0
Use Code 1000 - RESIDENTIAL Neighborhood 1010 - OAK RIDGE I
Land Code 9057 - FOX RUN MEADOWS Super Neighborhood 900 - BASALT / EL JEBEL AREA
Size 4.28 Location Adjustment 110
SubArea ACTUAL EFFECTIVE HEATED FOOTPRINT
Land L 1
Total 1.00
Value Rate Rate Rate Rate
Property Record Card
Eagle County
A#: R027960 P#: 239127300001 As of: 10/27/2020 Page 1 of 4
Land Occurrence 1
$209,000 209,000.00
Single Family Residence Occurrence 1
Abstract Code 1212 - SINGLE FAM.RES-
IMPROVEMTS
Percentage 100.0
Use Code 1000 - RESIDENTIAL Neighborhood 1010 - OAK RIDGE I
Building Type 121200 - SFR Arch Style 15 - A FRAME
Exterior Wall 14 - WD SID AVG Percentage 100.0
Roof Cover 10 - WD SHINGLE Roof Structure 9 - A-FRAME
Interior Wall 5 - DRYWALL Percentage 100.0
Floor 14 - CARPET INV
23 - CERAMIC TL
Percentage 80
20
Heating Fuel 3 - GAS Heating Type 5 - HT WTR B/B
Air Conditioning 1 - NONE Actual Year Built 1969
Bedrooms 3 Bathrooms 2.5
Construction Quality 4 - AVERAGE Effective Year Built 2002
Fixtures 9 Rooms 8
Units 1 Units 1
Super Neighborhood 900 - BASALT / EL JEBEL AREA Stories 3 - STORIES 3.0
Use Code 1000 - RESIDENTIAL Garage 1.5 - GARAGE 351-500
SubArea ACTUAL EFFECTIVE HEATED FOOTPRINT
BAS 840.0 840.0 840.0 840.0
FBM 792.0 633.6 792.0 792.0
FOP 288.0 86.4 288.0
FUS 346.0 346.0 346.0 346.0
GDF 461.3 461.3
SPC 96.0 9.6 96.0
WDD 304.0 60.8 304.0
Total 3,127.30 1,976.40 1,978.00 3,127.30
Value Rate Rate Rate Rate
$421,840 134.89 213.44 213.27 134.89
Property Record Card
Eagle County
A#: R027960 P#: 239127300001 As of: 10/27/2020 Page 2 of 4
Single Family Residence Occurrence 1
Sketch by Apex Medina™35.0'24.0'35.0'24.0'
BAS
840.0 ft²10.0'24.0'10.0'WDD 240.0 ft²33.0'24.0'33.0'24.0'
FBM
792.0 ft²12.0'24.0'12.0'FOP
288.0 ft²22.5'20.5'22.5'20.5'
GDF
461.3 ft²11.0'5.0'8.0'24.0'8.0'5.0'11.0'12.0'8.0'
SPC
96.0 ft²
8'8'WDD
64.0 ft²
14'
FUS
346.0 ft²
Extra Feature Occurrence 1
XFOB Code 104 - SHED A Abstract Code 1212 - SINGLE FAM.RES-
IMPROVEMTS
Percentage 100.0 Use Code 1000 - RESIDENTIAL
Neighborhood 1010 - OAK RIDGE I
SubArea ACTUAL EFFECTIVE HEATED FOOTPRINT
XFOB Units 150
Total 150.00
Value Rate Rate Rate Rate
$1,290 8.60
Property Record Card
Eagle County
A#: R027960 P#: 239127300001 As of: 10/27/2020 Page 3 of 4
Extra Feature Occurrence 1
Sketch by Apex Medina™12'12.5'12'12.5'
150.0 ft²
SHED
Abstract Summary
Code Classification Actual Value Taxable
Value
Actual
Override
Taxable
Override
1112 SINGLE FAM.RES.-LAND $209,000 $14,940 NA NA
1212 SINGLE FAM.RES-IMPROVEMTS $423,130 $30,250 NA NA
Total $632,130 $45,190 NA NA
Property Record Card
Eagle County
A#: R027960 P#: 239127300001 As of: 10/27/2020 Page 4 of 4