Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
22931 Frying Pan Rd - 247111402002
Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970) 328-8730 Fax: (970) 328-7185 Permit Permit No. OWTS-027841-2023 Permit Type: OWTS Permit Work Classification: New Permit Status: Active Issue Date: 9/14/2023 Expires: 1/12/2024 On-Site Wastewater Treatement System Project Address Parcel Number 22931 FRYING PAN RD, BASALT AREA,247111402002 Owner Information Address Cleve & Kerry Williams 850 Vista DR Phone: Cell: (970) 948-8679 Email: cleve850@gmail.com Inspections: For Inspections Call: (970) 328-8755 Engineer Phone Email Daniel Dennison ddennison@hceng.com Contractor License Number Phone Email Walters Company, Inc info@walterscompany.net(970) 379-5737OWTSPL-000206-20 22 Permitted Construction / Details: Install the new system exactly as depicted in the High Country Engineering design dated, stamped and signed on September 9th, 2023 by Daniel R Dennison, PE. This system is designed to accommodate the maximum daily flows for (4) 2-bedroom trailers, (1) 1-bedroom trailer, (1) 2-bedroom cabin, (1) 1-bedroom cabin and a future 1 bedroom for a total of 13 bedrooms. The OWTS consists of seven sewer lines from the trailers and cabins. A Valley Precast 2,000 gallon concrete, single compartment septic tank followed by a Valley Precast 2,000 gallon concrete, two-compartment septic tank equipped with an Orenco PF500511 high head pump set to dose 390 gallons per dose. The STA consists of 10 rows of 21 chambers for a total of 210. An ADV will be at the high point of the system and accessible at grade. Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections necessary to certify the installation and assure the functionality of the system. System certification, along with photos and a record drawing is required to be submitted to and approved by Eagle County Environmental Health prior to the use of the system or occupancy of the dwelling. THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT Issued by: Environmental Health Department, Eagle County, CO Danielle Salinsky Date September 14, 2023 CONDITIONS 1. 2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED 3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT 4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED Thursday, September 14, 2023 1 8/30/23, 7:49 AM Application For Onsite Wastewater Treatment System- New OWTS, Major, and Minor Repairs https://docs.google.com/forms/d/1JEp6VTO_YlvOuG7DGY78Oi60DTRdCCQM_2Ty7QqUOhE/edit#response=ACYDBNj_n2iAxUqJ10PaodarMpPPL…1/17 Proper ty Information https://property.eaglecounty.us/assessor/taxweb/search.jsp 22931 frying pan Rd 2471-114-00-023 1 acre Application For Onsite Wastewater Treatment System- New OWTS, Major, and Minor Repairs INCOMPLETE APPLICATIONS MAY NOT BE ACCEPTED It is recommended that you apply for an OWTS Permit and Building Permit concurrently. State law requires the OWTS Permit to be issued prior to the Building Permit. OWTS Permits expire after 120 days without an active building permit. Physical Address * Tax Parcel Number:* Lot Size: 8/30/23, 7:49 AM Application For Onsite Wastewater Treatment System- New OWTS, Major, and Minor Repairs https://docs.google.com/forms/d/1JEp6VTO_YlvOuG7DGY78Oi60DTRdCCQM_2Ty7QqUOhE/edit#response=ACYDBNj_n2iAxUqJ10PaodarMpPPL…2/17 Residential/Single Family Residential/ Multi Family Commercial/Industrial Other: 13 Private Well Public Spring Surface Ownership and Contact Information Building Type:* Number of Bedrooms (if residential), or type of use (if commercial)* Water Supply:* If Public, Name of Supplier 8/30/23, 7:49 AM Application For Onsite Wastewater Treatment System- New OWTS, Major, and Minor Repairs https://docs.google.com/forms/d/1JEp6VTO_YlvOuG7DGY78Oi60DTRdCCQM_2Ty7QqUOhE/edit#response=ACYDBNj_n2iAxUqJ10PaodarMpPPL…3/17 Cleve Williams 970-948-8679 858 vista hi dr Carbondale Co 81623 Cleve850@gmail.com Cleve williams 970-948-8679 Cleve850@gmail.com Proper ty Owner * Owner Phone Number * Owner Mailing Address Owner Email Address * Applicant/Contact Person:* Applicant Phone Number * Applicant Email Address * 8/30/23, 7:49 AM Application For Onsite Wastewater Treatment System- New OWTS, Major, and Minor Repairs https://docs.google.com/forms/d/1JEp6VTO_YlvOuG7DGY78Oi60DTRdCCQM_2Ty7QqUOhE/edit#response=ACYDBNj_n2iAxUqJ10PaodarMpPPL…4/17 Licensed Systems Contractor Only Licensed Systems Contractors approved by Eagle County are authorized to perform work on OWTS in Eagle County. A list of Licensed Systems Contractors is available on the website: https://drive.google.com/ le/d/1avu8QVUecGCiUTYK3FE3JiVKBO5AlLca/view?usp=sharing Owtspl-000206-2022 970-945-2851 Info@walterscompany.net Licensed System Contractor Name/ License #* Contractor Phone Number * Contractor Email * 8/30/23, 7:49 AM Application For Onsite Wastewater Treatment System- New OWTS, Major, and Minor Repairs https://docs.google.com/forms/d/1JEp6VTO_YlvOuG7DGY78Oi60DTRdCCQM_2Ty7QqUOhE/edit#response=ACYDBNj_n2iAxUqJ10PaodarMpPPL…5/17 New Installation- $1423 - New Builds of Residence or ADU Major Repair- $1023 - Full OWTS or Soil Treatment Area (STA) repair or replacement Minor Repair- $623- Tank Replacement Only Alterations - Alteration- $623- Bedroom Additions/ADU Additions/Remodels to an existing permitted OWTS. Small Repair- $223 - Sewer pipe replacements, pump replacements. Like-for-like replacement of component in the original Professionally Engineered Design. Does not change the way the system was designed to function. may include connections to auxiliary structures that do not increase daily ow rate. Work that does not require a permit includes : adding risers and/or tank lid replacements, tee replacement, cleanout replacements, and very minor ve feet or less of straight sewer pipe replacement where the contractor will submit scope of work and before and after photos to ECPHA New Installation- $1423 - New Builds of Residence or ADU The State Law requires that the OWTS permit be issued before the building permit is issued. If your application is incomplete, it will delay the issuance of your OWTS permit, and the issuance of the building permit. Eagle County Board of Health declares that its general policy is to require the use of public sewer systems where and whenever feasible and to limit the installation of OWTS only to areas that are not feasible for connection to public sewer. Eagle County will not issue an OWTS permit where the structure to be served is within the applicable Water and Sanitation District that provides public sewer, unless the public service provider is not willing to serve the structure, and authorizes the use of an OWTS. ALL OWTS IN EAGLE COUNTY MUST BE DESIGNED BY A COLORADO REGISTERED PROFESSIONAL ENGINEER. https://www.eaglecounty.us/environmentalhealth/septicsystems OWTS Permit Application is for (For definitions of permit type go to https://docs.google.com/document/d/10KeutJAAb3GKeDvynMjuAiW6aek4- n3Utn723ulspIs/edit?usp=sharing) * 8/30/23, 7:49 AM Application For Onsite Wastewater Treatment System- New OWTS, Major, and Minor Repairs https://docs.google.com/forms/d/1JEp6VTO_YlvOuG7DGY78Oi60DTRdCCQM_2Ty7QqUOhE/edit#response=ACYDBNj_n2iAxUqJ10PaodarMpPPL…6/17 High country Engeneering Dan Dennison 9709458676 DDennison@hceng.com All of the Following Must be Summitted to be Considered a Complete Application: Electronically (preferred) to environment@eaglecounty.us By mail to Eagle County Environmental Health, PO Box 179, Eagle, CO 81631 Dropped off at Eagle County O ce, Community Development Department 500 Broadway in Eagle Dropped off at Eagle County O ce, 20 Eagle County Drive in El Jebel Professional Engineer Name:* Engineer Phone Number:* Engineer Email:* Satisfactory design with site plan and soil profile results from a Colorado Registered Professional Engineer will be submitted * 8/30/23, 7:49 AM Application For Onsite Wastewater Treatment System- New OWTS, Major, and Minor Repairs https://docs.google.com/forms/d/1JEp6VTO_YlvOuG7DGY78Oi60DTRdCCQM_2Ty7QqUOhE/edit#response=ACYDBNj_n2iAxUqJ10PaodarMpPPL…7/17 Online (2.5% convenience fee) https://client.pointandpay.net/web/eaglecoenvhealth By mail to Eagle County Environmental Health, PO Box 179, Eagle, CO 81631 Dropped off at Eagle County O ce, Community Development Department 500 Broadway in Eagle Dropped off at Eagle County O ce, 20 Eagle County Drive in El Jebel The State Law requires that the OWTS permit be issued before the building permit is issued. Incomplete application, designs, will delay the issuance of the OWTS permit, and the issuance of the building permit/ An OWTS permit must be issued to the Licensed Systems Contractor prior to any installation, repair, or alteration work is performed. The contracted Licensed Systems Contractor must receive the permit from ECEH before the OWTS is installed. Completing this application does not constitute a permit. Eagle County’s review and approval of the Engineer’s design is required before a permit will be issued. Major Repair- $1023 Full Replacement of the System or Tank and/or Soil Treatment Area (STA) repair or replacement. Tank Only Replacement is considered a Minor Repair. Environmental Health Prioritizes the Review of Repair Applications and Designs “Repair” means restoration of functionality and/or treatment by reconstruction, relocation, or replacement of an on-site wastewater treatment system or any component thereof in order to allow the system to function as intended. The $1423 Permit Fee will submitted * I agree and understand that:* 8/30/23, 7:49 AM Application For Onsite Wastewater Treatment System- New OWTS, Major, and Minor Repairs https://docs.google.com/forms/d/1JEp6VTO_YlvOuG7DGY78Oi60DTRdCCQM_2Ty7QqUOhE/edit#response=ACYDBNj_n2iAxUqJ10PaodarMpPPL…8/17 Emergency Use Permit May Be Required Concurrently with the issuance of a repair permit, the ECPHA may issue an emergency use permit authorizing continued use of a malfunctioning system on an emergency basis for a period not to exceed the period stated in the repair permit. Such an emergency use permit may be extended, for good cause shown, in the event repairs may not be completed in the period stated in the repair permit through no fault of the owner or occupant and only if the owner or occupant will continue to make repairs to the system. Malfunctioning. The OWTS or component within is not performing as designed, but not failing Failing. Sewage is leaking on the gound, into the ground untreated. Sewage is backing up into the house. E uent is ponding, daylighting, or being disposed of without secondary treatment from a STA. Other: ALL OWTS IN EAGLE COUNTY MUST BE DESIGNED BY A COLORADO REGISTERED PROFESSIONAL ENGINEER. https://www.eaglecounty.us/environmentalhealth/septicsystems The system is * If the system is failing please describe any emergency use steps being taken. Professional Engineer Name:* 8/30/23, 7:49 AM Application For Onsite Wastewater Treatment System- New OWTS, Major, and Minor Repairs https://docs.google.com/forms/d/1JEp6VTO_YlvOuG7DGY78Oi60DTRdCCQM_2Ty7QqUOhE/edit#response=ACYDBNj_n2iAxUqJ10PaodarMpPPL…9/17 All of the Following Must be Summitted to be Considered a Complete Application: Electronically (preferred) to environment@eaglecounty.us By mail to Eagle County Environmental Health, PO Box 179, Eagle, CO 81631 Dropped off at Eagle County O ce, Community Development Department 500 Broadway in Eagle Dropped off at Eagle County O ce, 20 Eagle County Drive in El Jebel Online (2.5% convenience fee) https://client.pointandpay.net/web/eaglecoenvhealth By mail to Eagle County Environmental Health, PO Box 179, Eagle, CO 81631 Dropped off at Eagle County O ce, Community Development Department 500 Broadway in Eagle Dropped off at Eagle County O ce, 20 Eagle County Drive in El Jebel Engineer Phone Number:* Engineer Email:* Satisfactory design with site plan and soil profile results from a Colorado Registered Professional Engineer will be submitted * The $1023 Permit Fee will submitted * 8/30/23, 7:49 AM Application For Onsite Wastewater Treatment System- New OWTS, Major, and Minor Repairs https://docs.google.com/forms/d/1JEp6VTO_YlvOuG7DGY78Oi60DTRdCCQM_2Ty7QqUOhE/edit#response=ACYDBNj_n2iAxUqJ10PaodarMpPP…10/17 The State Law requires that the OWTS permit be issued before the building permit is issued. Incomplete application, designs, will delay the issuance of the OWTS permit, and the issuance of the building permit/ An OWTS permit must be issued to the Licensed Systems Contractor prior to any installation, repair, or alteration work is performed. The contracted Licensed Systems Contractor must receive the permit from ECEH before the OWTS is installed. Completing this application does not constitute a permit. Eagle County’s review and approval of the Engineer’s design is required before a permit will be issued. Minor Repair- $623- Tank Replacement Only “Repair” means restoration of functionality and/or treatment by reconstruction, relocation, or replacement of an on-site wastewater treatment system or any component thereof in order to allow the system to function as intended. Please note: repairs or replacement of the Soil Treatment Area are considered a Major Repair, other components may qualify for a small repair permit Emergency Use Permit May Be Required Concurrently with the issuance of a repair permit, the ECPHA may issue an emergency use permit authorizing continued use of a malfunctioning system on an emergency basis for a period not to exceed the period stated in the repair permit. Such an emergency use permit may be extended, for good cause shown, in the event repairs may not be completed in the period stated in the repair permit through no fault of the owner or occupant and only if the owner or occupant will continue to make repairs to the system. I agree and understand that:* 8/30/23, 7:49 AM Application For Onsite Wastewater Treatment System- New OWTS, Major, and Minor Repairs https://docs.google.com/forms/d/1JEp6VTO_YlvOuG7DGY78Oi60DTRdCCQM_2Ty7QqUOhE/edit#response=ACYDBNj_n2iAxUqJ10PaodarMpPP…11/17 Malfunctioning. The tank or component within is not performing as designed, but not failing Failing. Sewage is leaking on the ground, into the ground untreated. Sewage is backing up into the house. Tank is not water-tight. Other: ALL OWTS IN EAGLE COUNTY MUST BE DESIGNED BY A COLORADO REGISTERED PROFESSIONAL ENGINEER. https://www.eaglecounty.us/environmentalhealth/septicsystems The tank is * If the system is failing please describe any emergency use steps being taken. Professional Engineer Name:* Engineer Phone Number:* Engineer Email:* 8/30/23, 7:49 AM Application For Onsite Wastewater Treatment System- New OWTS, Major, and Minor Repairs https://docs.google.com/forms/d/1JEp6VTO_YlvOuG7DGY78Oi60DTRdCCQM_2Ty7QqUOhE/edit#response=ACYDBNj_n2iAxUqJ10PaodarMpPP…12/17 All of the Following Must be Summitted to be Considered a Complete Application: Electronically (preferred) to environment@eaglecounty.us By mail to Eagle County Environmental Health, PO Box 179, Eagle, CO 81631 Dropped off at Eagle County O ce, Community Development Department 500 Broadway in Eagle Dropped off at Eagle County O ce, 20 Eagle County Drive in El Jebel Online (2.5% convenience fee) https://client.pointandpay.net/web/eaglecoenvhealth By mail to Eagle County Environmental Health, PO Box 179, Eagle, CO 81631 Dropped off at Eagle County O ce, Community Development Department 500 Broadway in Eagle Dropped off at Eagle County O ce, 20 Eagle County Drive in El Jebel An OWTS permit must be issued to the Licensed Systems Contractor prior to any installation, repair, or alteration work is performed. The contracted Licensed Systems Contractor must receive the permit from ECEH before the OWTS is installed. Completing this application does not constitute a permit. Eagle County’s review and approval of the Engineer’s design is required before a permit will be issued. Alteration- $623 Bedroom Additions/ADU Additions/Remodels to an existing permitted OWTS. Satisfactory design with site plan from a Colorado Registered Professional Engineer will be submitted: * The $623 Permit Fee will submitted * I agree and understand that:* 8/30/23, 7:49 AM Application For Onsite Wastewater Treatment System- New OWTS, Major, and Minor Repairs https://docs.google.com/forms/d/1JEp6VTO_YlvOuG7DGY78Oi60DTRdCCQM_2Ty7QqUOhE/edit#response=ACYDBNj_n2iAxUqJ10PaodarMpPP…13/17 State Law requires that the OWTS permit be issued before the building permit is issued. If your application is incomplete, it will delay the issuance of your OWTS permit, and the issuance of the building permit. ALL OWTS IN EAGLE COUNTY MUST BE DESIGNED BY A COLORADO REGISTERED PROFESSIONAL ENGINEER. https://www.eaglecounty.us/environmentalhealth/septicsystems All of the Following Must be Summitted to be Considered a Complete Application: Existing OWTS Permit Number of Alteration:* Professional Engineer Name:* Engineer Phone Number:* Engineer Email:* 8/30/23, 7:49 AM Application For Onsite Wastewater Treatment System- New OWTS, Major, and Minor Repairs https://docs.google.com/forms/d/1JEp6VTO_YlvOuG7DGY78Oi60DTRdCCQM_2Ty7QqUOhE/edit#response=ACYDBNj_n2iAxUqJ10PaodarMpPP…14/17 Electronically (preferred) to environment@eaglecounty.us By mail to Eagle County Environmental Health, PO Box 179, Eagle, CO 81631 Dropped off at Eagle County O ce, Community Development Department 500 Broadway in Eagle Dropped off at Eagle County O ce, 20 Eagle County Drive in El Jebel Online (2.5% convenience fee) https://client.pointandpay.net/web/eaglecoenvhealth By mail to Eagle County Environmental Health, PO Box 179, Eagle, CO 81631 Dropped off at Eagle County O ce, Community Development Department 500 Broadway in Eagle Dropped off at Eagle County O ce, 20 Eagle County Drive in El Jebel The State Law requires that the OWTS permit be issued before the building permit is issued. Incomplete application, designs, will delay the issuance of the OWTS permit, and the issuance of the building permit/ An OWTS permit must be issued to the Licensed Systems Contractor prior to any installation, repair, or alteration work is performed. The contracted Licensed Systems Contractor must receive the permit from ECEH before the OWTS is installed. Completing this application does not constitute a permit. Eagle County’s review and approval of the Engineer’s design is required before a permit will be issued. Small Repair- $223 Sewer pipe replacements, pump replacements. Like-for-like replacement of component in the original Professionally Engineered Design. Does not change the way the system was designed to function. May Satisfactory evaluation of existing design and proposed changes required with site plan and soil profile results from a Colorado Registered Professional Engineer will be submitted * The $623 Permit Fee will submitted I agree and understand that:* 8/30/23, 7:49 AM Application For Onsite Wastewater Treatment System- New OWTS, Major, and Minor Repairs https://docs.google.com/forms/d/1JEp6VTO_YlvOuG7DGY78Oi60DTRdCCQM_2Ty7QqUOhE/edit#response=ACYDBNj_n2iAxUqJ10PaodarMpPP…15/17 include tanks. May include connections to auxiliary structures that do not increase daily ow rate. All repairs and connections must be completed by a licensed Eagle County OWTS Contractor. State Law requires that the OWTS permit be issued before the building permit is issued. If your application is incomplete, it will delay the issuance of your OWTS permit, and the issuance of the building permit. All of the Following Must be Summitted to be Considered a Complete Application: Online (2.5% convenience fee) https://client.pointandpay.net/web/eaglecoenvhealth By mail to Eagle County Environmental Health, PO Box 179, Eagle, CO 81631 Dropped off at Eagle County O ce, Community Development Department 500 Broadway in Eagle Dropped off at Eagle County O ce, 20 Eagle County Drive in El Jebel Existing OWTS Permit Number:* Describe the repair work to be done:* The $223 Permit Fee will submitted * 8/30/23, 7:49 AM Application For Onsite Wastewater Treatment System- New OWTS, Major, and Minor Repairs https://docs.google.com/forms/d/1JEp6VTO_YlvOuG7DGY78Oi60DTRdCCQM_2Ty7QqUOhE/edit#response=ACYDBNj_n2iAxUqJ10PaodarMpPP…16/17 The State Law requires that the OWTS permit be issued before the building permit is issued. Incomplete application, designs, will delay the issuance of the OWTS permit, and the issuance of the building permit. It is best to submit the building permit to Community Development concurrently with this permit as most building permits have longer review times. An OWTS permit must be issued to the Licensed Systems Contractor prior to any installation, repair, or alteration work is performed. The contracted Licensed Systems Contractor must receive the permit from ECEH before the OWTS is installed. Completing this application does not constitute a permit. Eagle County’s review and approval of the work and existing PE design is required before a permit will be issued. Work that does not require a permit May Include: adding risers and/or tank lid replacements, tee replacement, cleanout replacements, and very minor ve feet or less of straight sewer pipe replacement where the contractor will submit scope of work and before and after photos to ECPHA All work on a OWTS must be completed by a licensed Eagle County OWTS Contractor. I agree and understand that:* Existing OWTS Permit Number: (if not known please state so)* Describe the repair work to be done:* 8/30/23, 7:49 AM Application For Onsite Wastewater Treatment System- New OWTS, Major, and Minor Repairs https://docs.google.com/forms/d/1JEp6VTO_YlvOuG7DGY78Oi60DTRdCCQM_2Ty7QqUOhE/edit#response=ACYDBNj_n2iAxUqJ10PaodarMpPP…17/17 Photos of before and after will be submitted to Eagle County Environmental Health environment@eaglecounty.us Only an Eagle County Licensed Systems Contractor must perform work on an OWTS. Any additional work may require a permit and will be submitted for review to Eagle County EH This form was created inside of Eagle County Government. I agree and understand that:* Forms Inspection Result Eagle County, Colorado P.O. Box 179 500 Broadway Eagle, CO Phone: (970) 328-8730 Fax: (970) 328-7185 IVR Phone: 1-866-701-3307 Inspection Number: INSP-527009-2023 Permit Number: OWTS-027841-2023 Inspection Date: 10/05/2023 Inspector: Salinsky, Danielle Permit Type: OWTS Permit Inspection Type: OWTS Final Inspection Work Classification: NewOwner:Cleve & Kerry Williams Job Address:22931 FRYING PAN RD IVR Pin Number:199936 BASALT AREA, CO Project:<NONE> Parcel Number:247111402002 Contractor:Phone: (970) 945-2851 / Cell: (970) 379-5737Walters Company, Inc Inspection Status: Approved Inspection Notes Inspector Comments Added Item: Septic Tank 10/5/2023 had not been installed yet, contractor to send pictures. A Valley Precast 2,000 gallon concrete, single compartment septic tank followed by a Valley Precast 2,000 gallon concrete, two-compartment septic tank equipped with an Orenco PF500511 high head pump set to dose 390 gallons per dose was installed. Added Item: Record Drawing Received 11/9/2023. Added Item: Record Photos Received 11/7/2023. Added Item: Site and Soil Inspected and verified 10/5/2023. Added Item: Final Certification Letter Received 11/7/2023. Added Item: General Plan Received 8/28/2023. Added Item: Soil Treatment Area (STA) Inspected and verified 10/5/2023. The STA consists of 10 rows of 21 chambers for a total of 210. Added Item: Identification of Systems Contractor Walters Co was the licensed installer. Thursday, November 9, 2023 For more information visit: http://www.eaglecounty.us Page 1 of 2 Thursday, November 9, 2023 For more information visit: http://www.eaglecounty.us Page 2 of 2 FRYING PA N R O A D ( C . R . 1 0 4 ) SHARED GRAVEL DRIVEWAY 2 1 EAGLE COUNTY PITKIN COUNTY PITKIN CO. PARCEL ID. NO. 247111400003 22931 FRYING PAN ROAD PITKIN CO. PARCEL ID. NO. 247111400004 FRYING PAN ROADN07°37'42"W 154.93'S10°15'12"E 95.80'S00°00'00"E 140.09'S89°47'13"E 32.53' S80°21'04 " W 1 6 0 . 6 3 ' S80°25'47 " W 8 0 . 3 4 ' S82°25'18"W 44.26' scale: page: Project No: drawn by: checked by: date: file: HIGH COUNTRY ENGINEERING, INC. 1517 BLAKE AVENUE, STE 101, GLENWOOD SPRINGS, CO 81601 PHONE (970) 945-8676 FAX (970) 945-2555 www.hceng.com 1 2201743 1" = 30' J:/sdskproj/2201743Z/OWTS-AsbuiltMap.dwg 11-8-23 DRD DRD OWTS ABSORPTION FIELD RELOCATED LOCATION OF 22931 FRYING PAN ROAD MEREDITH, CO LONESOME B LLLP OWTS DESIGN CALCULATIONS EAGLE COUNTY 2018:(4) 2-BEDROOM TRAILERS, (1) 1-BEDROOM TRAILER, (1) 2-BEDROOM CABIN,AND (1) 1-BEDROOM CABIN (LT1 EFFLUENT) = 12 EXISTINGOVERSIZE FUTURE SYSTEM FOR 1 EXTRA BEDROOM = 13 PROPOSED :·(75 GAL/PERSON/DAY x 2 PERSONS/BEDROOM x 13 BEDROOM)·DESIGN FLOW = Q = 1,950 GALLONS·DUE TO EACH BUILDING BEING 3 BEDROOMS OR LESS, NO REDUCTION FORBEDROOM COUNTS WAS UTILIZED.TANK SIZING:·TABLE 9-1 EAGLE COUNTY OWTS REGULATION 13 BEDROOMS= 3,500GALLONS·USE (1) 2,000-GALLON ONE-COMPARTMENT TANK WITH 4" PIPED OVERFLOWTO SECOND 2,000 GALLON TWO COMPARTMENT TANK WITH HIGHPRESSURE DOSING PUMP IN SECOND CHAMBER OF THE SECOND TANK.FIRST CHAMBER IN SECOND TANK TO BE 1,000 GALLONS, SECONDCHAMBER TO BE 1,006 GALLONS.·TOTAL "FIRST" CHAMBER CAPTURE 3,142 GALLONS, SECOND CHAMBERWITH PUMP 1,066 GALLONS = 4,208 GALLONS)·SECOND CHAMBER WILL HAVE A DOSING RATE OF 200 GALLONS PER DOSEAND A PUMP VOLUME REDUCTION OF 100 GALLONS FOR DISPLACEMENT,PUTTING THE REDUCED HOLDING CAPACITY AT 766 GALLONS.·TOTAL VOLUME MINUS REDUCTIONS: 3,908 GALLONS (3,500 REQUIRED)ABSORPTION AREA SIZING:·EXISTING SOILS TEST SHOW 63% GRAVEL FROM THE OVERALL TESTPUTTING THIS IN THE 0 SOILS TYPE CATEGORY . REMAINING IS 37% OF THETEST SOILS AT (75% SAND, 19% SILT AND 6% CLAYS). REMAINING SOILSWITH GRAVELS FACTORED OUT (SANDY LOAM - 0)·DUE TO SAND BED REQUIREMENTS, A PRESSURE DOSING SYSTEM HASBEEN DESIGNED.·LTAR RATE = 0.80 GAL/SF·CALCULATED ABSORPTION AREA = A=(Qd/LTAR)=(1,950/0.8)··Qd = DESIGN FLOW = GAL/DAY··ABSORPTION AREA = 2,438 SF··0% REDUCTION FOR CHAMBERS DUE TO SYSTEM SIZETOTAL AREA REQUIRED FOR 13 BEDROOMS = 2,438 SF INFILTRATOR CHAMBERS IN TRENCH SYSTEM (12 SF PER CHAMBER):·ABSORPTION AREA PER DESIGN 2,438/12 SF PER CHAMBER.·203 CHAMBERS REQUIRED.··(9) TRENCHES ROWS AT 23 CHAMBERS LONG. (207 CHAMBERS)C/OC/OC/OC/OC/OC/OC/OC/OEXISTING SHAREDGRAVELDRIVEWAYEXISTING GRAVELDRIVEWAY(APPARENT EASEMENT)HIGHWATER LINEOF FRYING PAN RIVER STATE HWY NO. 104 PORATH PARCEL1.00± ACRESLONESOME B, LLLP PARCEL1.10± ACRESOWNERJOANIE W. HAGGERTYP.O. BOX 1693BASALT, CO 81621OWNERJAMES LEONARD2033 BUCKEYE DRIVEINGLESIDE, TX 78362OWNERJOHN WOOLLEY & LARRY ALAN& BETTY NEILSENP.O. BOX 3422BASALT, CO 81621OWNERRUEDI SOUTHSHORE HOAP.O. BOX 1328SANTA FE, NM 87504OWNERUNITED STATES FOREST SERVICEOWNERUNITED STATESFOREST SERVICETWO BEDROOMTRAILERTWO BEDROOMTRAILERTWO BEDROOMTRAILERTWO BEDROOMTRAILERONE BEDROOMTRAILERONE BEDROOMCABIN WELL HOUSEEXISTING SHAREDGRAVELDRIVEWAY12EAGLE COUNTYPITKIN COUNTYEAGLE COUNTYPITKIN COUNTY ADJUSTMENTPARCEL B4,087 SQ.FT .C/O2 BEDROOMCABINPARCEL NO: 2471-114-00-023PHYSICAL ADDRESS: 22931 FRYING PAN RDCREEK ROAD, BASALT, CO 81621SEC. 11, T8 SOUTH, R84 WESTBYNO.DATE BYPROJECT NO.OR 534 - 06700 IN METRO DENVER UNDERGROUND MEMBER UTILITIES EXCAVATE FOR THE MARKING OF BEFORE YOU DIG, GRADE, OR CALL 2-BUSINESS DAYS IN ADVANCE 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATIONREVISIONHIGH COUNTRY ENGINEERING, INC. PHONE (970) 945-8676 - FAX (970) 945-2555 www.hceng.com drawn by: checked by: date: file: 1517 BLAKE AVENUE, STE 101, GLENWOOD SPRINGS, CO 816012201743OWTS-1CLEVE WILLIAMS EAGLE COUNTY, COLORADO LONESOME B, LLLP OWTS DESIGN PLAN SHEET DRD DRD 3-31-21 OWTS 1 9/14/21 REVISED TO INCLUDE BUILDING ON PORATH.DRD 2 12/16/21 REVISED FOR ACCURATE BEDROOM COUNT.DRD 3 2/25/21 REVISED TO SHOW OFFSITE WELLS.DRD EXISTING GRAVEL ROADWAYPROPOSED SEPTIC GRAVITY LINEEXISTING MAJOR CONTOUREXISTING MINOR CONTOUREXISTING FENCEPROPOSED SWALE FLOWLINE BYNO.DATE BYPROJECT NO.OR 534 - 06700 IN METRO DENVER UNDERGROUND MEMBER UTILITIES EXCAVATE FOR THE MARKING OF BEFORE YOU DIG, GRADE, OR CALL 2-BUSINESS DAYS IN ADVANCE 1-800-922-1987 CENTER OF COLORADO CALL UTILITY NOTIFICATIONREVISIONHIGH COUNTRY ENGINEERING, INC. PHONE (970) 945-8676 - FAX (970) 945-2555 www.hceng.com drawn by: checked by: date: file: 1517 BLAKE AVENUE, STE 101, GLENWOOD SPRINGS, CO 816012201743OWTS-2CLEVE WILLIAMS EAGLE COUNTY, COLORADO LONESOME B, LLLP OWTS DESIGN DETAIL SHEET DRD DRD RD OWTS 1 9/14/21 REVISED TO INCLUDE BUILDING ON PORATH.DRD 2 12/16/21 REVISED FOR ACCURATE BEDROOM COUNT.DRD 3 2/25/22 REVISED TO SHOW OFFSITE WELLS.DRD OWTS DESIGN CALCULATIONS EAGLE COUNTY 2018: (4) 2-BEDROOM TRAILERS, (1) 1-BEDROOM TRAILER, (1) 2-BEDROOM CABIN, AND (1) 1-BEDROOM CABIN (LT1 EFFLUENT) = 12 EXISTING OVERSIZE FUTURE SYSTEM FOR 1 EXTRA BEDROOM = 13 PROPOSED : ·(75 GAL/PERSON/DAY x 2 PERSONS/BEDROOM x 13 BEDROOM) ·DESIGN FLOW = Q = 1,950 GALLONS ·DUE TO EACH BUILDING BEING 3 BEDROOMS OR LESS, NO REDUCTION FOR BEDROOM COUNTS WAS UTILIZED. TANK SIZING: ·TABLE 9-1 EAGLE COUNTY OWTS REGULATION 13 BEDROOMS= 3,500 GALLONS ·USE (1) 2,000-GALLON ONE-COMPARTMENT TANK WITH 4" PIPED OVERFLOW TO SECOND 2,000 GALLON TWO COMPARTMENT TANK WITH HIGH PRESSURE DOSING PUMP IN SECOND CHAMBER OF THE SECOND TANK. FIRST CHAMBER IN SECOND TANK TO BE 1,000 GALLONS, SECOND CHAMBER TO BE 1,006 GALLONS. ·TOTAL "FIRST" CHAMBER CAPTURE 3,142 GALLONS, SECOND CHAMBER WITH PUMP 1,066 GALLONS = 4,208 GALLONS) ·SECOND CHAMBER WILL HAVE A DOSING RATE OF 200 GALLONS PER DOSE AND A PUMP VOLUME REDUCTION OF 100 GALLONS FOR DISPLACEMENT, PUTTING THE REDUCED HOLDING CAPACITY AT 766 GALLONS. ·TOTAL VOLUME MINUS REDUCTIONS: 3,908 GALLONS (3,500 REQUIRED) ABSORPTION AREA SIZING: ·THE NORTH GRADATION TEST THAT SITS WITHIN THE PROPERTY ABSORPTION FIELD WAS PERFORMED BY HP GEOTECH ON 12/17/2015 (JOB NUMBER 115 585A). EXISTING SOILS TEST SHOW 63% GRAVEL FROM THE OVERALL TEST PUTTING THIS IN THE 0 SOILS TYPE CATEGORY . REMAINING IS 37% OF THE TEST SOILS AT (75% SAND, 19% SILT AND 6% CLAYS). REMAINING SOILS WITH GRAVELS FACTORED OUT (SANDY LOAM - 0) ·DUE TO SAND BED REQUIREMENTS, A PRESSURE DOSING SYSTEM HAS BEEN DESIGNED. ·LTAR RATE = 0.80 GAL/SF ·CALCULATED ABSORPTION AREA = A=(Qd/LTAR)=(1,950/0.8) ··Qd = DESIGN FLOW = GAL/DAY ··ABSORPTION AREA = 2,438 SF ··0% REDUCTION FOR CHAMBERS DUE TO SYSTEM SIZE TOTAL AREA REQUIRED FOR 13 BEDROOMS = 2,438 SF INFILTRATOR CHAMBERS IN TRENCH SYSTEM (12 SF PER CHAMBER): ·ABSORPTION AREA PER DESIGN 2,438/12 SF PER CHAMBER. C/O C/O C/O C/O C/O C/O C/O C/O EXISTING SHARED GRAVEL DRIVEWAY EXISTING GRAVEL DRIVEWAY (APPARENT EASEMENT) HIGHWATER LINE OF FRYING PAN RIVER STATE HW Y N O . 1 0 4 PORATH PARCEL 1.00± ACRES LONESOME B, LLLP PARCEL 1.09± ACRES OWNER JOANIE W. HAGGERTY P.O. BOX 1693 BASALT, CO 81621 OWNER JAMES LEONARD 2033 BUCKEYE DRIVE INGLESIDE, TX 78362 OWNER JOHN WOOLLEY & LARRY ALAN & BETTY NEILSEN P.O. BOX 3422 BASALT, CO 81621 OWNER RUEDI SOUTHSHORE HOA P.O. BOX 1328 SANTA FE, NM 87504 OWNER UNITED STATES FOREST SERVICE OWNER UNITED STATES FOREST SERVICE TWO BEDROOM TRAILER TWO BEDROOM TRAILER TWO BEDROOM TRAILER TWO BEDROOM TRAILER ONE BEDROOM TRAILER ONE BEDROOM CABIN WELL HOUSE SHARED GRAVEL DRIVEWAY 1 2 EAGLE COUNTY PITKIN COUNTY EAGLE COUNTY PITKIN COUNTY ADJUSTMENTPARCEL B4,087 SQ.FT. C/O 2 BEDROOM CABIN PARCEL NO: 2471-114-00-023 PHYSICAL ADDRESS: 22931 FRYING PAN RD CREEK ROAD, BASALT, CO 81621 SEC. 11, T8 SOUTH, R84 WEST BYNO.DATEBYPROJECT NO.OR 534 - 06700 IN METRO DENVERUNDERGROUND MEMBER UTILITIESEXCAVATE FOR THE MARKING OFBEFORE YOU DIG, GRADE, ORCALL 2-BUSINESS DAYS IN ADVANCE1-800-922-1987CENTER OF COLORADOCALL UTILITY NOTIFICATIONREVISIONHIGH COUNTRY ENGINEERING, INC.PHONE (970) 945-8676 - FAX (970) 945-2555www.hceng.comdrawn by:checked by:date:file:1517 BLAKE AVENUE, STE 101, GLENWOOD SPRINGS, CO 816012201743 OWTS-1CLEVE WILLIAMSEAGLE COUNTY, COLORADOLONESOME B, LLLPOWTS DESIGN PLAN SHEETDRDDRD3-31-21OWTS19/14/21REVISED TO INCLUDE BUILDING ON PORATH.DRD212/16/21REVISED FOR ACCURATE BEDROOM COUNT.DRD32/25/21REVISED TO SHOW OFFSITE WELLS.DRD49/9/23REVISED OWTS DESIGN.DRDEXISTING GRAVEL ROADWAY PROPOSED SEPTIC GRAVITY LINE EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR EXISTING FENCE PROPOSED SWALE FLOWLINE BYNO.DATEBYPROJECT NO.OR 534 - 06700 IN METRO DENVERUNDERGROUND MEMBER UTILITIESEXCAVATE FOR THE MARKING OFBEFORE YOU DIG, GRADE, ORCALL 2-BUSINESS DAYS IN ADVANCE1-800-922-1987CENTER OF COLORADOCALL UTILITY NOTIFICATIONREVISIONHIGH COUNTRY ENGINEERING, INC.PHONE (970) 945-8676 - FAX (970) 945-2555www.hceng.comdrawn by:checked by:date:file:1517 BLAKE AVENUE, STE 101, GLENWOOD SPRINGS, CO 816012201743 OWTS-2CLEVE WILLIAMSEAGLE COUNTY, COLORADOLONESOME B, LLLPOWTS DESIGN DETAIL SHEETDRDDRDRDOWTS19/14/21REVISED TO INCLUDE BUILDING ON PORATH.DRD212/16/21REVISED FOR ACCURATE BEDROOM COUNT.DRD32/25/22REVISED TO SHOW OFFSITE WELLS.DRD49/9/23REVISED OWTS DESIGN.DRD 11/8/23, 7:18 AM 71867367218__A57AC72C-8254-48C0-A8E8-E3DADA6450C1.jpg https://mail.google.com/mail/u/0/#all/FMfcgzGwHVVFFJqtLFkKPqZTcFFlcXNx?projector=1&messagePartId=0.1 1/1 11/8/23, 7:19 AM IMG_0548.jpg https://mail.google.com/mail/u/0/#all/FMfcgzGwHVVFFJqtLFkKPqZTcFFlcXNx?projector=1&messagePartId=0.1 1/1 11/8/23, 7:18 AM IMG_2892.jpg https://mail.google.com/mail/u/0/#all/FMfcgzGwHVVFFJqtLFkKPqZTcFFlcXNx?projector=1&messagePartId=0.1 1/1 11/8/23, 7:18 AM IMG_2893.jpg https://mail.google.com/mail/u/0/#all/FMfcgzGwHVVFFJqtLFkKPqZTcFFlcXNx?projector=1&messagePartId=0.1 1/1 11/8/23, 7:18 AM IMG_2894.jpg https://mail.google.com/mail/u/0/#all/FMfcgzGwHVVFFJqtLFkKPqZTcFFlcXNx?projector=1&messagePartId=0.1 1/1 All product and performance assertions are based on proper design, installation, operation, and maintenance according to Orenco’s current published documentation. Orenco Systems® • 800-348-9843 • +1 541-459-4449 • www.orenco.com Orenco® PF-Series 60Hz, 1-Phase Pumps Technical Data Sheet NTD-PU-PF-1 Rev. 12 © 03/23 Page 1 of 4 Applications Orenco’s 60Hz, 1-phase, 4in (100mm) Submersible Effluent Pumps are designed to transport screened effluent (with low TSS counts) from septic or dosing tanks. These pumps are engineered using lightweight, corrosion-resistant stainless steel and polymers, and are field ser- viceable and repairable with common tools. They’re also CSA and UL certified to US and Canadian safety standards for effluent pumps. PF-Series pumps are used in a variety of applications, including pressurized drainfields, packed-bed filters, mounds, aerobic units, effluent irrigation, liquid-only (effluent) sewers, wetlands, lagoons, and more. These pumps are designed to be used with a Biotube® pump vault or after a secondary treatment system. Franklin Super Stainless motor Franklin liquid end Discharge connection Suction connection LR80980 LR2053896 Powered by General To specify this pump for your installation, require the following: • Minimum 24-hour run-dry capability (liquid end) with no deteriora- tion in pump life or performance* • 1/8in (3mm) bypass orifice to ensure flow recirculation for motor cooling and to prevent air binding • 1/8in (3mm) mesh intake screen to limit solids • Liquid-end repair kit availability for better long-term cost to own • TRI-SEAL™ floating impeller design on 10, 20, and 30gpm (0.6, 1.3, and 1.9L/sec) models; floating stack design on 50 and 75gpm (3.2 and 4.7L/sec) models • Franklin Electric Super Stainless motors are rated for continuous use and frequent cycling, with surge arrestors, hermetically sealed motor housing for moisture-free windings, and Kingsbury-type thrust bearing for thrust absorption • Thermal overload protection trips at 203-221˚F (95-105˚C) for 1-phase motors through 1.5hp (1.12kW) • Type SOOW 600V motor cable (model PF751512 uses 14 AWG, SJOOW, 300V cord) * Not applicable for 5hp (3.73kW) models Standard Models See Specifications on page 2 for a list of standard pumps. For a complete list of available pumps, call Orenco. Product Code Diagram PF - Nominal flow, gpm (L/sec): 10 = 10 (0.6) 20 = 20 (1.3) 30 = 30 (1.9) 50 = 50 (3.2) 75 = 75 (4.7) Pump, PF-Series Frequency: 1 = 1-phase, 60Hz Voltage, nameplate: 1 = 115* 2 = 230 Horsepower (kW): 05 = 1/2hp (0.37) 07 = 3/4hp (0.56) 10 = 1hp (0.75) 15 = 1 1/2hp (1.12) 20 = 2hp (1.50) 30 = 3hp (2.24) 50 = 5hp (3.73) Cord length, ft (m):‡ Blank = 10 (3) 20 = 20 (6) 30 = 30 (9) 50 = 50 (15) Check valve: Blank = no internal check valve CV = internal check valve† * 1/2hp (0.37kW) only † Available for 10gpm (0.6L/sec), 1/2hp (0.37kW) ‡ Note: 20ft cords are available only for pumps through 1 1/2hp CLK = ClickTight™ compatible - Orenco® PF-Series 60Hz, 1-Phase Pumps - Technical Data Sheet NTD-PU-PF-1 Rev. 12 © 03/23 Page 2 of 4 Orenco Systems® • 800-348-9843 • +1 541-459-4449 • www.orenco.com Pump Model Design gpm (L/sec)Horsepower (kW)PhaseNameplate voltageActual voltageDesign flow ampsMax ampsDischarge size and material1Length in (mm)Min. liquid level in (mm)2Weight lb (kg)3Rated cycles per dayPF100511 9 10 (0.6)0.50 (0.37)1 115 120 12.7 12.7 1¼in GFP 23.0 (584)16 (406)26 (12)300 PF100511CV 9 10 (0.6)0.50 (0.37)1 115 120 12.7 12.7 1¼in GFP 23.0 (584)16 (406)26 (12)300 PF100512 9 10 (0.6)0.50 (0.37)1 230 240 6.3 6.3 1¼in GFP 23.0 (584)16 (406)26 (12)300 PF100712 4, 5, 9 10 (0.6)0.75 (0.56)1 230 240 8.3 8.3 1¼in GFP 25.9 (658)17 (432)30 (14)300 PF101012 5, 6, 9 10 (0.6)1.00 (0.75)1 230 240 9.6 9.6 1¼in GFP 27.9 (709)18 (457)33 (15)100 PF200511 9 20 (1.3)0.50 (0.37)1 115 120 12.3 12.5 1¼in GFP 22.3 (566)18 (457)25 (11)300 PF200512 9 20 (1.3)0.50 (0.37)1 230 240 6.4 6.5 1¼in GFP 22.5 (572)18 (457)26 (12)300 PF201012 4, 5, 9 20 (1.3)1.00 (0.75)1 230 240 10.5 10.5 1¼in GFP 28.4 (721)20 (508)33 (15)100 PF201512 4, 5 20 (1.3)1.50 (1.12)1 230 240 12.4 12.6 1¼in GFP 34.0 (864)24 (610)41 (19)100 PF300511 9 30 (1.9)0.50 (0.37)1 115 120 11.8 11.8 1¼in GFP 21.3 (541)20 (508)28 (13)300 PF300512 9 30 (1.9)0.50 (0.37)1 230 240 6.2 6.2 1¼in GFP 21.3 (541)20 (508)25 (11)300 PF300712 9 30 (1.9)0.75 (0.56)1 230 240 8.5 8.5 1¼in GFP 24.8 (630)21 (533)29 (13)300 PF301012 4, 9 30 (1.9)1.00 (0.75)1 230 240 10.4 10.4 1¼in GFP 27.0 (686)22 (559)32 (15)100 PF301512 4, 5 30 (1.9)1.50 (1.12)1 230 240 12.6 12.6 1¼in GFP 32.8 (833)24 (610)40 (18)100 PF302012 5, 6, 7 30 (1.9)2.00 (1.49)1 230 240 11.0 11.0 1¼in SS 35.5 (902)26 (660)44 (20)100 PF303012 5, 6, 7, 8 30 (1.9)3.00 (2.23)1 230 240 16.8 16.8 1¼in SS 44.5 (1130)33 (838)54 (24)100 PF305012 5, 6, 7, 8 30 (1.9)5.00 (3.73)1 230 240 25.6 25.8 1¼in SS 66.5 (1689)53 (1346)82 (37)100 PF500511 9 50 (3.2)0.50 (0.37)1 115 120 12.1 12.1 2in SS 20.3 (516)24 (610)27 (12)300 PF500512 9 50 (3.2)0.50 (0.37)1 230 240 6.2 6.2 2in SS 20.3 (516)24 (610)27 (12)300 PF500712 9 50 (3.2)0.75 (0.56)1 230 240 8.5 8.5 2in SS 23.7 (602)25 (635)31 (14)300 PF501012 9 50 (3.2)1.00 (0.75)1 230 240 10.1 10.1 2in SS 27.0 (686)26 (660)35 (16)100 PF501512 4 50 (3.2)1.50 (1.12)1 230 240 12.5 12.6 2in SS 32.5 (826)30 (762)41 (19)100 PF503012 4, 5, 7, 8 50 (3.2)3.00 (2.23)1 230 240 17.7 17.7 2in SS 52.0 (1321)37 (940)55 (25)100 PF505012 5, 6, 7, 8 50 (3.2)5.00 (3.73)1 230 240 26.2 26.4 2in SS 77.0 (1956)55 (1397)64 (29)100 PF751012 9 75 (4.7)1.00 (0.75)1 230 240 9.9 10.0 2in SS 27.0 (686)27 (686)34 (15)100 PF751512 75 (4.7)1.50 (1.12)1 230 240 12.1 12.3 2in SS 33.4 (848)30 (762)44 (20)100 1. GFP = glass-filled polypropylene; SS = stainless steel. The 1 1/4in NPT GFP discharge is 2 7/8in octagonal across flats; the 1 1/4in NPT SS discharge is 2 1/8in octagonal across flats; and the 2in NPT SS discharge is 2 7/8in hexagonal across flats. Discharge is NPT threaded receptacle-style port, US nominal size, to accommodate Orenco discharge hose and valve assemblies. Consult your Orenco distributor about fittings to connect hose and valve assemblies to metric-sized piping. 2. Minimum liquid level is for single pumps when installed in an Orenco Biotube Pump Vault or Universal Flow Inducer. In other applications, minimum liquid level should be top of pump. Consult Orenco for more information. 3. Weight includes carton and 10ft (3m) cord. 4. High-pressure discharge assembly required. 5. Do not use cam-lock option (Q) on discharge assembly. 6. Custom discharge assembly required for these pumps. Contact Orenco. 7. Capacitor pack (sold separately or installed in a custom control panel) required for this pump. Contact Orenco. 8. Torque locks are available for all pumps, and they are supplied with 3hp and 5hp pumps. 9. ClickTight TM compatible. Specifications NTD-PU-PF-1 Rev. 12 © 03/23 Page 3 of 4 Orenco® PF-Series 60Hz, 1-Phase Pumps - Technical Data Sheet Orenco Systems® • 800-348-9843 • +1 541-459-4449 • www.orenco.com Materials of Construction Discharge Glass-filled polypropylene or stainless steel Discharge bearing Engineered thermoplastic (PEEK) Diffusers Glass-filled PPO (SABIC’s NORYL™ GFN3 resin) Impellers Celanese’s Celcon® acetal copolymer on 10, 20, and 30gpm models; 50gpm impellers are NORYL GFN3 resin Intake screen Polypropylene Suction connection Stainless steel Drive shaft 7/16in hexagonal stainless steel, 300 series Coupling Sintered stainless steel, 300 series Shell Stainless steel, 300 series Motor Franklin Electric motor filled with deionized water and propylene glycol for constant lubrication. Stainless steel shell. Using a Pump Curve A pump curve helps you determine the best pump for your system. Pump curves show the relationship between flow (gpm or L/sec) and pressure (total dynamic head or TDH), providing a graphical representation of a pump’s optimal performance range. Pumps perform best at their nominal flow rate – the value, measured in gpm, expressed by the first two numerals in an Orenco pump nomenclature. These graphs use solid lines to show the optimal pump operation range. Dashed lines indicate flow rates outside of the optimal range for each pump. For the most accurate pump specifica- tions, use Orenco’s PumpSelect™ software. Pump Curves Total dynamic head (TDH) in feetFlow in gallons per minute (gpm) 2 481012 14 16 186 400 450 350 300 250 200 150 100 50 PF1007 PF1010 PF1005 PF10 Series, 60Hz, 0.5 - 1.0hp 0 0 Total dynamic head (TDH) in feetFlow in gallons per minute (gpm) 5102025303540150 400 350 300 250 200 150 100 50 0 PF2005 PF2010 PF2015 PF20 Series, 60Hz, 0.5 - 1.5hp Orenco® PF-Series 60Hz, 1-Phase Pumps - Technical Data Sheet NTD-PU-PF-1 Rev. 12 © 03/23 Page 4 of 4 Orenco Systems® • 800-348-9843 • +1 541-459-4449 • www.orenco.com Pump Curves, cont.Total dynamic head (TDH) in feetFlow in gallons per minute (gpm) 5 10 20 25 30 35 40 45150 800 900 700 600 500 400 300 200 100 0 PF3005 PF3007 PF3010 PF3020 PF3030 PF3050 PF30 Series, 60Hz, 0.5 - 5.0hp PF3015 Total dynamic head (TDH) in feetFlow in gallons per minute (gpm) 450 400 350 300 250 200 150 100 50 0 10 02040506070809030 PF5050 PF5030 PF5015 PF5010 PF5007 PF5005 PF50 Series, 60Hz, 0.5 - 5.0hp Total dynamic head (TDH) in feetFlow in gallons per minute (gpm) 10 20 40 50 60 70 80 90 100300 80 90 100 70 60 50 40 30 20 10 0 PF75 Series, 60Hz, 1.0 - 1.5hpPF7515 PF7510