HomeMy WebLinkAbout700 Sorrel Hills Dr - 193921101010INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway • Eagle, CO 81631
Telephone: (970) 328-8755
COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1758-98 BP NO. 11794
OWNER: JOHANN AND KAREN OBERLOHR PHONE: 970-926-3366
MAILING ADDRESS: P.O. BOX 464, EDWARDS, CO 81632
APPLICANT: SAME PHONE:
SYSTEM LOCATION: 0700 SORREL HILLS DRIVE, EAGLE, CO TAX PARCEL NO. 1939-211-01-010
LICENSED INSTALLER: HOBBS EXCAVATING, STEWART HOBBS LICENSE NO. 10-98 PHONE: 524-7447
DESIGN ENGINEER: PHONE NO.
INSTALLATION HEREBY GRANTED FOR THE FOLLOWING:
1-1000 GALLON TANK FOR THE BARN & CARETAKER UNIT PER RAY MERRY
1-1250 GALLON SEPTIC TANKS 1969 SQUARE FEET OF ABSORPTION AREA VIA 64 INFILTRATOR UNITS AS REQUESTED BY OWNER.
SPECIAL REQUIREMENTS:_ INSTALL IN SERIAL DISTRIBUTION IN TRENCHES WITH CLEAN OUTS BETWEEN BUILDINGS AND TANKS, AND
INSPECTION PORTALS IN EACH TRENCH. INSTALL TANKS CLOSE TO BUILDINGS. PLACE CLEAN OUTS ON EACH SIDE OF THE DRIVEWAY,
AND EVERY ONE HUNDRED FEET OF PIPE RUN. RAKE ALL TRENCH SURFACES TO PREVENT SMEARING OF SOILS, AND FENCE OFF LEACH
FIELD TO PREVENT LIVESTOCK FROM GRAZING IN THE AREA. CALL ENVIRONMENTAL HEALTH FOR FINAL INSPECTION PRIOR TO BACK
FILLING ANY PART OF THE INSTALLATION. ALL CONNECTIONS BETWEEN BUILDINGS, TANKS, AND MAIN SEWER LINE NEED TO BE IN-
SPECTED PRIOR TO BACK FILLING. BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED WITHOUT FINAL APPROVAL OF THE
SEPTIC SYSTEM.
ENVIRONMENTAL HEALTH APPROVAL: RAYMOND P. MERRY DATE: APRIL 6, 1998
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS,
ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING
REQUIREMENTS, CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO
BE LICENSED.
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL
THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: 1984 SQUARE FEET (VIA 64 INFILTRATOR UNITS)
INSTALLED CONCRETE SEPTIC TANK: 1000 GALLONS, FOR CARETAKER UNIT, LOCATED 126 DEGREES AND 50' FROM THE CLEANOUT
INSTALLED CONCRETE SEPTIC TANK: 1500 GALLONS, FOR MAIN RESIDENCE, LOCATED 110 FEET EAST OF THE MAIN HOUSE
COMMENTS: 10/15/98 INSTALLATION FOR THE ADDITIONAL TANK FOR THE MAIN RESIDENCE WILL NEED A SEPARATE INSPECTION.
PHOTOS OF 2ND TANK INSTALLATION RECEIVED ALONG WITH SITE PLAN AND INVOICE DOCUMENTING TANK SIZE ON 2/11/00. 211D INSPEC-
TION WAS NOT PERFORMED BY ENVIRONMENTAL HEALTH DEPARTMENT, BUT DOCUMENTATION WAS SUFFICIENT FOR FINAL APPROV-
AL.
ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN
WORK IS COMPLETED.
ENVIRONMENTAL HEALTH APPROVAL91 <I DATE: FEBRUARY 18, 2000
r
INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway • Eagle, CO 81631
Telephone: (970) 328-8755
COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1758-98 BP NO. 11794
OWNER: JOHANN AND KAREN OBERLOHR PHONE: 970-926-3366
MAILING ADDRESS: P.O. BOX 464. EDWARDS, CO 81632
APPLICANT: SAME PHONE:
SYSTEM LOCATION: 0700 SORREL HILLS DRIVE, EAGLE. CO TAX PARCEL NO. 1939-211-01-010
LICENSED INSTALLER: HOBBS EXCAVATING, STEWART HOBBS LICENSE NO. 10-98 PHO M: 524-7447
DESIGN ENGINEER: PHONE NO.
INSTALLATION HEREBY G FOR THE Fp4LOWING
ay.0 't I / 0 • ysa 'k Caw'�7r��e� � f' -t-
-Sd= 1-1150 GALLON SEPTIC TANKS 1969 SQUARE FEET OF ABSORPTION AREA VIA 64 INFILTRATOR UESTED BY OWNER.
SPECIAL REQUIREMENTS: INSTALL IN SERIAL DISTRIBUTION IN TRENCHES WITH CLEAN OUTS BETWEEN BUILDINGS AND TANKS, AND
INSPECTION PORTALS IN EACH TRENCH. INSTALL TANKS CLOSE TO BUILDINGS. PLACE CLEAN OUTS ON EACH SIDE OF THE DRIVEWAY,
AND EVERY ONE HUNDRED FEET OF PIPE RUN. RAKE ALL TRENCH SURFACES TO PREVENT SMEARING OF SOILS. AND FENCE OFF LEACH
FIELD TO PREVENT LIVESTOCK FROM GRAZING IN THE AREA. CALL ENVIRONMENTAL HEALTH FOR FINAL INSPECTION PRIOR TO BACK
FILLING ANY PART OF THE INSTALLATION. ALL CONNECTIONS BETWEEN BUILDINGS. TANKS. AND MAIN SEWER LINE NEED TO BE IN-
SPECTED PRIOR TO BACK FILLING. BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED WITHOUT FINAL APPROVAL OF THE
SEPTIC SYSTEM.
ENVIRONMENTAL HEALTH APPROVAL: / DATE: APRIL 6. 1998
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY lisE@IIITIS EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS,
ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104,1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING
REQUIRRA NTS, CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. CP. 41= IV, S..=3114.0-.',.^^ : Q1W ES AI: i PERSONWHO CONSTRUCTS, ALT IM- Z OR INS T. Z.1Z A :.^Nrri---Ur'.L SEWAGE DISPOSAL SYSTEM TO
BE LICENSED.
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR):
"NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL -
THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: 1984 SQUAREFEET(VIA 64 TNFTT,TRATOR TTNTTS )
INSTALLED CONCRETE. TANK: 1000 GALLONS IS LOCATED 126 DEGREES AND 50 FEET FROM
THE CLEANOUT NEAR THE. CARETAKW9 TMTT_
COMMENTS: THE. TNSTAT.T.ATTnN FnR TNR nnnTTTn1`TaT TANK FOR THE MAIN RF$ CE WILL NEED A SEP-
ARATE INSPECTION.
ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN
WORK IS COMPLETED. CC��
ENVIRONMENTAL HEALTH APPROVAL DATE: OCTORER 15, 199R
(Site Plan MUST be attached)
ISDS Permit # l l f-� - G e -
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY
P. O. BOX 179
EAGLE, CO 81631
328-8755/927-3823 (El Jebel)
**************************************************************************
* PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00
* *
* MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER"
PROPERTY OWNER: OinFA1��n -V V O Te�ro NO Y101A y- PHONE:
MAILING ADDRESS:
APPLICANT/CONTACT PERSON. AXAS Nev-(-O v\- PHONE: (Q`7�4)�12f� 's3blo
MAILING ADDRESS: " v lbw _
LICENSED ISDS CONTRACTOR: SAewt.Av-" 4066 5 PHONE: ( ) S?-'f ILI4`l
COMPANY/DBA: �06bs ADDRESS: -ROx T!��3 6�112!5yW& ap 1�i L z l
**************************************************************************
PERMIT APPLICATION IS FOR: (ICJ New Installation ( ) Alteration ( ) Repair
LOCATION OF PROPOSED INDIVppIDUAL SEWAGE DISPOSAL SYSTEM:
Building Permit # �'� t 4 ( if known)
Legal Description: Subdivision: S0v.11d Wih5 Filing:_Block: Lot No.3 /*
Tax Parcel Number: 1 �_ - 2 i .. I - 0 k - 0 10 Lot Size : '36 -qc,
Street Address:
BUILDING TYPE: (Check applicable category)
(,K) Residential/Single Family(1P"MaYy-►SEcr0Kjev)f Number of Bedrooms a,
( ) Residential/Multi-Family* / Number of Bedrooms
( ) Commercial/Industrial* Type
TYPE OF WATER SUPPLY: (Check applicable category)
() Well ( ) Spring ( ) Surface
( ) Public Name of Supplier:
*These systems require design by a Registered Professional Engineer
SIGNATURE: Date:
TO BE COMPLETED Y THE COUNTY
AMOUNT PAID:-0 RECEIPT #: DATE:
CHECK #: 43 1i CASHIER:
Community Development Department .
(970) 328-8730
Fax: (970) 328-7185
TDD: (970) 328-8797
EAGLE COUNTY, COLORADO
DATE: April 6, 1998
TO: Hobbs Excavating
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
FROM: Environmental Health Division
RE: Issuance of Individual Sewage Disposal System Permit No. 1758-98, Tax Parcel
#1939-211-01-010. Property Location: 0700 Sorrell Hills Rd., Eagle, CO.,
Oberlohr residence.
Enclosed is your ISDS Permit No. 1758-98. It is valid for 120 days. The enclosed copy of the
permit must be posted at the installation site. Any changes in plans or specifications invalidates
the permit unless otherwise approved.
Also enclosed is the ISDS Final Inspection Completeness Form. The items on this form need
to be completed before you call for your final inspection. Also, please note any special
conditions which may have been placed on the permit. If all items are not completed, a
reinspection fee of $42.50 must be paid before a reinspection is made.
Please call our office well in advance to allow for scheduling of final inspection. Your building
permit TCO will not be issued until fmal approval has been given for the ISDS Permit.
Permit specifications are minimum requirements only, and should be brought to the property
owner's attention.
This permit does not indicate conformance with other Eagle County requirements.
If you have any questions, please feel free to contact the Environmental Health Division at 328-
8755.
cc: files
Enclosure: ISDS Final Inspection Completeness Form
Community Development Department
(970)328-8730
FAX (970) 328-7185
TDD (970) 328-8797
Email: eccmdeva@vail.net
http: //www.eagle-county.com
February 18, 2000
Johann & Karen Oberlohr
P.O. Box 464
Edwards, CO 81632
EAGLE COUNTY, COLORADO
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
RE: Final of ISDS Permit 91758-98, Tax Parcel #1939-211-01-010. Property location: 0700
Sorrel Hills Drive, Eagle, CO.
Dear Mr. & Mrs. Oberlohr:
This letter is to inform you that the above referenced ISDS Permit has been inspected and
finalized. Enclosed is a copy to retain for your records. This permit does not indicate
compliance with any other Eagle County requirements. Also enclosed is a brochure regarding
the care of your septic system.
Be aware that later changes to your building may require appropriate alterations of your septic
system.
If you have any questions regarding this permit, please contact the Eagle County Environmental
Health Division at (970) 328-8755.
Sincerely,
Janet Kohl
Environmental Health Department
Eagle County Community Development
ENCL: Informational Brochure
Final ISDS Permit
cc: files
Community Development Department
(970) 328-8730
FAX (970) 328-7185
TDD (970) 328-8797
Email: eccmdeva@vail.net
http: //www.eagle-county.com
February 15, 2000
Johann Oberlohr
P.O. Box 464
Edwards, CO 81632
Re: ISDS Permit #1758-98
Dear Mr. Oberlohr:
EAGLE COUNTY, COLORADO
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
Thank you for supplying the photographs of the installation.of the septic tank for your main
residence. After reviewing them with Heather Savalox, the Health Specialist who did the final
inspection of the remaining portion of the system, it was determined that the following additional
information is needed:
The size of the tank is difficult to determine from a photograph, so an invoice indicating the
capacity will be needed.
2. Also, as with any installation, we need to verify the location of the tank with distance
measurements from the house to the tank and cleanout, and in which direction the leach field
is located and how far away from the tank it is. These measurements are taken to verify the
location of all of the components of the entire system and become part of the permanent
record for your property.
3. On the site plan drawn by the inspector at the final inspection of the leach field and tank for
the caretaker unit, the future stub -in for the main house was indicated. We need to know
how far down the effluent line that connection was made, and how far away the leach field is
located.
I am including the site plan that Heather drew, and the one you submitted with your application, so
that you may indicate on either one where the above items are located. If you have any questions,
please call me at 328-8755.
Sincerely,
J-'� k�4j_
Janet Kohl
Eagle County Environmental Health
cc: Hobbs Excavating, Stewart Hobbs
enclosures: site plans of ISDS Permit #1758-98
Community Development Department
(970) 328-8730
FAX (970) 328-7185
TDD (970) 328-8797
Email: eccmdeva@vail.net
http: //www.eagle-county.com
EAGLE COUNTY, COLORADO
October 15, 1998
Hans & Karen Oberlohr
P.O. Box 464
Edwards, CO 81632
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
RE: Final of ISDS Permit #1758-98, Tax Parcel #1939-211-01-010. Property location: 0700
Sorrel Hills Drive, Eagle, CO.
Dear Mr. & Mrs. Oberlohr:
This letter is to inform you that the above referenced ISDS Permit has been inspected and
finalized. Enclosed is a copy to retain for your records. This permit does not indicate
compliance with any other Eagle County requirements. Also enclosed is a brochure regarding
the care of your septic system.
Be aware that later changes to your building may require appropriate alterations of your septic
system.
If you have any questions regarding this permit, please contact the Eagle County Environmental
Health Division at (970) 328-8755.
Sincerely,
Janet Kohl
Environmental Health Department
Eagle County Community Development
ENCL:Informational Brochure
Final ISDS Permit
cc: files
ceoa& vl�W�1-1(0-w4
v�
4-71
1,
10U3 rLK1111
I
PERCOLATION TEST
EAGLE COUNTY ENVIRONMENTAL HEALTH DEPT.
+fm/v AN
'RIPTION:
_10 V a L Loy-
4' C 03 211 — 61
DRESS: OL S11
ELLING: NUMBEROFBEDROOMS __7
PRE-SOAKED: YES— NO
whr"Vn nVnr"Tff
2
3
1
2
3
1
2
3
&%^.L
1
CA
2 _J3
bulL rhutl
�'�v
�••Zl
�,��
.F �te�
i � �y
1 i
� .�
1� c�
Y/1
11/14
3'Zf
F3
17
1 3'
�,
� ,
i '1d
it?
-71S
14
5'
wl�
68
6'1
7
ON+
4
E
Time to drop last inch— -5rm
176D
PERC RATE: 0 VM121* MINIMUM SEPTIC TANK SIZE:)2,5D
I
MINIML LEACH FIELD SIZE. vl'GL
I f) t_ 1I-L", - - N-e-t V1 S
.5;j
COMM )EE TS. z
N a"j,,j /,Ire
.0 fi u
1,)L'u 4D ezoeqc
PERC TEST DONE BY:
TZ)
DATE:
Environmental Heal tb Officer
rev. 6/90ks Pe'51:'ln
/S. 5
FW RE DRtv6iA —� /
N 90WO0' E
24.38
Y
SEPTIC T,
z ;
LEAN TiFLb
W
q
s aoW44' E
_ 2.WW
PART OF
PARCEL 3A N
(TOTAL AREA OF PARCEL 3A - 36.523 ACRES)
Re
1327.E6
s a'sror w
ca.rc I.�.lccr
o Pla�st w
SD
62
i32
bark
cd
�a
l,sev j* . Col. Matt, Rovse
ISDS Permit # l 7 Sa " 99
Date S f l &
ISDS Final Inspection
Completeness Form
V Tank is 1000 gal. Tank Material �iC%Z�t C�✓e
✓ Tank is located qA"54�-. and 220degrees from ba,-A
(permanent landmark)
V Tank is located � ft. and 2�'degrees from CG�(C Krif'f �,��p�.rd C✓lGuh ��,,�
(permanent landmark)
iL Tank set level: ✓ Tank lids within 81, of fini•shed.grade.
✓ Size of field _�� ft2/`/ units lineal ft.
Technology i/la h97Y5
Cleanout is installed in between tank and house (+ 1/100ft) . +a(IS'��S
here is a "T" that goes down 14 inches in the inlet and
outlet of the tank.
Inlet and outlet is sealed with tar tape, rubber gasket etc.(0115'11Y
_y Tank has two compartments with the larger compartment closest to the
house.
Measure distance and relative direction to field.
I/ Depth of field 4 ft. w;IJ otd< / GLI�t� ►'.r. O%i'�
Soil interface raked. Q
✓ Inspection portals at the end of each trench.
v Proper distance to setbacks.
Chambers properly installed as per manufacturers specifications.
(Chambers latched, end plates properly installed, rocks removed from
trenches, etc.)
Type of pipe used for building sewer line 5Qf 3S leach fieldSP9.35
Other 07(bVr 42 e:C.S (J) � � (il4'/e�ir �i-r �,�� 5 . �i�G + 6j,a(,/ 1i4;"
I� 5 f-,, I c a rt fc I
Inspection meets requirements. ('D���/v�
Copy form to installer's file if recommendations for improvement were
suggested.
ACTION TAKEN:
Setbacks
Well Potable House Property Lake Dry Tank Drain
Water Lines line Stream Gulch
Field
100
25
20
10
50
25
10
10
Tank
50
10
5
10
50
10
*
10
s7D
C.d
Yt
ram•'^ � � ` 1 ���J:
l.. n
',•`�y ..� vim_ 14 � w ,;µ' y 4� � y �'i'.'j1! �•�.,aifr ,.�. C
'sir•• r{"I�kSynt _ ,' r a - -
■��1! Q1a`R,�i
71
`
+ _ y
x -+
At
Ole
f:�i-., ��� y - k1nt 1�1J• '.- Vi. \ y� •t� _ • _ � n •` � `, :i
It k-r
Al !F � � ,t f • r , r• �11.`�
dw
j
6 a ...
4F