HomeMy WebLinkAbout5548 Frying Pan Rd - 246701305001INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway • Eagle, CO 81631
Telephone: (970) 328-8755
COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1740-97 BP NO. N/A
OWNER: SUSAN MCCOY PHONE: 970-927-1005
MAILING ADDRESS: P.O. BOX 623 ASPEN, CO 81612
APPLICANT: DAN COKELY, SCHMUESER GORDON MEYER, INC. PHONE: 970-945-1004
SYSTEM LOCATION: 5448 FRYING PAN RD., BASALT, CO 81621 TAX PARCEL NO. 2 4 6 7 —013 — 0 5 —0 01
LICENSED INSTALLER: ASPEN EARTHMOVING, RICHARD STEVENS LICENSE NO. 36-97 PHONE: 970-963-0377
DESIGN ENGINEER: DAN COKELY, SCHMUESER GORDON MEYER. INC. PHONE NO. 970-945-1004
INSTALLATION HEREBY GRANTED FOR THE FOLLOWING:
2000 GALLON HOLDING TANK WITH AN ALARM TO SIGNAL WHEN PUMPING IS NECESSARY.
SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN DATED 10/17/97. ANY ADDITIONAL IMPROVEMENT TO THE SEPTIC SYS-
TEM WILL NEED A SEPARATE PERMIT APPLICATION. ENGINEER IS RESPOSIBLE FOR FINAL INSPECTION OF INSTALLATION
ENVIRONMENTAL HEALTH APPROVAL: c DATE: OCTOBER 30,1997
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY, INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS,
ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING
REQUIREMENTS, CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO
BE LICENSED.
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL
THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: Not applicable SQUARE FEET (VIA )
INSTALLED holdingTANK: 2,000 GALLONS IS LOCATED DEGREES AND FEET FROM
see site plan for location.
COMMENTS:
ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN
WORK IS COMPLETED. � ��
ENVIRONMENTAL HEALTH APPROVAL DATE: February 3, 1998
o1mcuL 1 Ulu 0117 7S11&0? b L/ O
(Site Plan MUST be attached)
ISDS Permit # 7 tl 0
APPLICATION POR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY
P. O. BOX 179
EAGLE, CO 81631
328-8755/927-3823 (El Jebel)
* PERMIT APPLICATION FEE $150.00
* PERCOLATION. TEST FEE $200.00
* MAKE 'ALL REMI'Y'TANCE PAYABLE TO : ' "EAGLE COUNTY TREASUREAP,
PROPERTY OWNER:
MAILING ADDRESS:
APPLICANT/CONTACT
MAILING ADDRESS:
fvjCc�V4
PHONE: ( q 9 _ 1 oa-9"
PHONE: (912154SLAOIA—
LICENSED ISDS CONTRACTOR: v1^" tYJNE • 3 �'s�0 1 �b
COMPANY / DDA : ADDRESS -
PERMIT APPLICATION IS FOR: { ) New Installation Alterati
Repair
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Building Permit # (if known)
Legal Description: Subdivision: CeQ;k Filing: � Lot Na.JA
Tax Parcel Number:
�
� Lot Size.-
Street Address: 5gL4B t-ie (vm vnv ld. 12(j .
BUILDING TYPE: (Check applicable category)
{ ) Residential/Single Family Number of Bedrooms { ) Residential%Multi-Family* Number of Bedrooms
(x,) Commercial/Industrial* Type
TYPE OF WATER SUPPLY: (Check applicable category)
(�) Well ( ) Spring ( ) Surface
(,) Public Name of Supplier:
*These system wire des' y a Registered Professional Engineer
7
SIGNATURE: Date: ICAI q-
TO BE COMPLETED BY THE COUNTY
AMOUNT PAID: I1b .16 RECEIPT #: •fo%jj DATE: I
CHECK #: / (a CASHIER:0 a
Community Development Department
(970) 328-8730
Fax: (970) 328-7185
TDD: (970) 328-8797
EAGLE COUNTY, COLORADO
Date: October 30, 1997
TO: Aspen Earthmoving
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
FROM: Environmental Health Division
RE: Issuance of Individual Sewage Disposal System Permit No. 1740-97. Tax Parcel #
2467=013-05-001. Property Location: 5448 Frying Pan Rd., Basalt, CO., McCoy
property.
Enclosed is your ISDS Permit No. 1740-97. It is valid for 120 days. The enclosed copy of the
permit must be posted at the installation site. Any changes in plans or specifications
invalidates the permit unless otherwise approved.
Systems designed by a Registered Professional Engineer must be certified by the Engineer
indicating that the system was installed as specified. Eagle County does not perform final
inspections on engineer designed systems. Your TCO will not be issued until our office
receives this certification.
Permit specifications are minimum requirements only, and should be brought to the property
owner's attention.
This permit does not indicate conformance with other Eagle County requirements.
If you have any questions, please feel free to contact the Environmental Health Division at 328-
8755.
cc: files
Schmueser Gordon Meyer, Dan Cokley
Community Development Department
(970) 328-8730
Fax: (970) 328-7185
TDD: (970) 328-8797
EAGLE COUNTY, COLORADO
February 3, 1998
Susan McCoy
P.O. Box 623
Aspen, CO 81612
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
RE: Final of ISDS Permit #1740-97, Tax Parcel #2467-013-05-001. Property location: 5448
Frying Pan Rd., Basalt, CO., barn holding tank.
Dear Ms. McCoy:
This letter is to inform you that the above referenced ISDS Permit has been inspected and
finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance
with any other Eagle County requirements.
Be aware that later changes to your building may require appropriate alterations of your septic
system.
If you have any questions regarding this permit, please contact the Eagle County Environmental
Health Division at (970) 328-8755.
Sincerely,
Janet Kohl
Environmental Health Department
Eagle County Community Development
ENCL: Final ISDS Permit
cc: files
(970) 945-1004
FAX (970) 945-5948
January 29, 1998
ENGINEERS
SG SURVEYORS
SCHMUESER
GORDON MEYER
Eagle County Environmental Health Department
P.O. Box 179
Eagle CO 81631
Attn: Heather
RE: ISDS Permit #1740-97
Tax Parcel #2467-013-05-001
5448 Frying Pan Road, Basalt CO
Dear Heather:
118 West 6th, Suite 200
Glenwood Springs, CO 81601
The purpose of this letter is to provide you with an inspection report for the above -referenced
property. The 2000 gallon holding tank with an alarm signal was installed October 31, 1997,
per the engineer design letter dated October 17, 1997 and Eagle County Septic Permit dated
October 30, 1997. The Owner is aware that any additional improvement to the septic system
will need a separate permit application as per the permit.
Sincerely,
SCHMUESER GORDON MEYER, INC.
Dan Cokley, P.
DC:lc/97099A.1
cc: Susan McCoy, P.O. Box 623, Aspen CO 81612
721
t� 25 �`��
SUSAH S. McCOY
P.O. BOX 623
Aspen, Colorado 81612
February 2, 1998
Eagle County Environmental Health Department
P.O. Box 179
Eagle, Colorado 81631
Attn: Heather
RE: ISDS Permit # 1740-97
Tax Parcel # 2467-013-05-001
5548 Frying Pan Road, Basalt, CO
Dear Heather:
I would like to make a formal request to extend my ISDS Permit
# 1740-97 into the 1998 construction year because we were unable to
finish the the leach field system in 1997 due to climatic
conditions.
The system is being designed by Dan Cokley with Schmueser, Gordon,
& Meyer, Inc. Mr. Cokley has sent you an inspection report,
however, he has not done a final inspection because the system has
not been completed yet.
If there is a problem extending the ISDS Permit into the 1998
construction year, please advise me. Thank you.
Sincerely,
VV"6
Susan S. McCoy
cc: Dan Cokley
file: ISDS.98
Community Development Department .
(970) 328-8730
Fax: (970) 328-7185
TDD: (970) 328-8797
EAGLE COUNTY, COLORADO
Susan S. McCoy
P.O. Box 623
Aspen, CO 81612
February 4, 1998
Dear Ms. McCoy,
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
I am writing this letter in response to your request to extend ISDS Permit #1740-97 for your
property located at 5448 Frying Pan Rd., Basalt, CO. This permit was issued October 30, 1997,
for the installation of a 2,000 gallon holding tank with an alarm signal to indicate when pumping
is necessary. The special requirements dictate that the installation be completed by a registered
engineer and that any additional improvements to the septic system, i.e., the addition of a leach
field, would require a separate permit application.
On January 29, 1998, I received correspondence from Dan Cokley at Schmueser Gordon Meyer,
Inc., regarding final inspection of your property. Since that time, your ISDS permit has been
completed and any additional work on the septic system located on your property would require
a separate ISDS application, as stated in your original permit. Please call me at (970) 328-8755
if you have any questions.
Sincerely,
Heather Savalox
Environmental Health Specialist
encl
PNPCWCT200 Pl*&hW42M,J (PZUMQ
--, — ... I...., ..._. - ..... — —11 �VLa �41 uir.irx%
Glenwood Springs Office:
FAX:
PROJECT: NJ C
PROJECT NO:
TO: �~�,-
FROM:
Comm
W-
SSLfJ�,lYPS
S
SCHhWESER GOADON MEYER, INC.
118 WEST 6TH STRE.RT, SWE 200
�r nDYAW-TV c^ $ mot
(9701 945-1004
1970) 945-5948
I I Original mailed.
13
Aspen Office: (9701 925-6727
FAX: 070) 926-4157
DATE.--- W
FAX: a 2-t--
I I Original not majad.
T1tis facsimae traasmiasion (and/or documents ac+eompan7i� a) may coptain co®fitlential information belonging to the
leader whit$ c prbo e . f flue areenanot
the lint
privilege. The !AtOrmatioa is intended only for the use of the individual
or entity named sieve. 2f yen are not the iateaded recipient, you are hareby noffod that any disclosure. copying,
distribretion, or the taking of any a+.don in reliatuce OR the contents of this information 6 strictly prohibited. If you have
received this traneadssloR in error,, pleme immediately notify us by telephone to arrange for return of the documents.
you.
Total pages (including this page). . Please call if this amount of pages was not reftived
ti
MURAL
,aj
. f"t
(970) 945-1004
FAX (970) 945-5948
October 17, 1997
ENGINEERS
SURVEYORS
M
SCHMUESER SG
GORDON MEYER
118 West 6th, Suite 200
Glenwood Springs, CO 81601
�L
Mr. Ray Merry
Eagle County Environmental Health
P.O. Box 179 `
Eagle CO 81631 \v
RE: Parcel 1A, South Taylor Creek Subdivision
Dear Ray:
I am writing you in regards to a property located approximately 5'/2 miles up the Frying Pan
River at 5448 Frying Pan Road in Eagle County, Colorado. Our firm was contacted by a
partner of a small stable operation with a capacity of four horses. The operation is run out
of an existing barn with a drywell-type septic system that is a non -conforming use. There is
also a small A -frame building located on the same property.
The existing septic system at the barn is not functioning properly and backs up effluent
through a floor drain located in the barn. This floor drain is used to drain water from washing
horses in the winter. There is also a bathroom in the barn containing a lavatory and a toilet.
The barn is typically occupied only by the horses and used during the day by the caretaker.
The caretaker does stay overnight occasionally to tend to sick and pregnant horses.
The owner intends to build a new residence on the property in the near future, at which time
he would construct a septic system to handle both the new residence ant the barn. Soil
investigation has been done recently by Bob Nelson, with Nelson Environmental Wastewater
Solutions. We have found acceptable percolation rates, but high groundwater situation which
would necessitate a mound system being installed. For the short term, we propose to replace
the existing drywell system with a 2000 gallon, baffled, concrete septic tank to serve as a
holding tank. Included in the design would be —an electric alarm system with a visual alarm
attached to the outside of the building in a prominent location. This would allow a pump to
be installed in the future to discharge to the future mound system.
We estimate the average use at the barn to consist of the following:
A maximum of two persons/day @ 15 gal/person/day = 30 gpd
2. Horse washing, 10-minute duration at 5 gpm = 50 qpd
Total = 80 gpd (max)
In the winter time, it is typical that the horses get washed approximately once per month,
while in the summer time, washings occur more frequently, but are done outside the barn.
We believe the average daily flow to the tank will be in the 15-20 gpd range. Assuming a
water -tight plumbing system and septic tank, the tank would need to be pumped
approximately every three months.
October 17, 1997
Mr. Ray Merry
Page 2
Please find enclosed a schematic site plan, septic tank and alarm detail. Please do not
hesitate to call should you have any questions or comments regarding this matter. Your
prompt review would be greatly appreciated.
Sincerely,
SCHMUESER GORDON MEYER, INC.
Dan Cokley, P.E.
DC:lc/97099A
Enclosure
cc: Rick Stevens, Aspen Earthmoving
Susan McCoy, P.O.B. 623, Aspen CO
4�,r J. cp��•, O
r
-olti 29799
t
�p1oIt4I9�- •'•�{4�
81612
UESER GORDON MEYER, INC.
1740-97 Tax# 'L46/—U1J—US—UU1
JOB NAME Lot #1A, S. Taylor Cr. MCCOY
5448 Frying Pan Rd. t��Gclt/h-
Rasalt - - ----- --
JOB NO.
G 1
BILL TO
DATE STARTE
DATE COMPLETED
DATE BILLED
okl Iv
3
g
JOB COST SUMMARY
TOTAL SELLING PRICE
TOTAL MATERIAL
00
TOTAL LABOR
INSURANCE
SALES TAX
MISC. COSTS
TOTAL JOB COST
GROSS PROFIT
LESS OVERHEAD COSTS
% OF SELLING PRICE
NET PROFIT
JOB FOLDER Product 278 ■OB FOLDER Printed In U.S.A.