Loading...
HomeMy WebLinkAbout200 Kings Lake Rd - 246907202006INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1733-97 BP NO. 11503 OWNER: KARINGA, LTD PHONE: 970-927-3132 MAILING ADDRESS: 7104 FRYING PAN RD., BASALT, CO 81621 APPLICANT: WILLIAM MARANO, 7104 FRYING PAN RD., BASALT, CO 81621 PHONE: 970-927-3132 SYSTEM LOCATION: 7104 FRYING PAN RD., BASALT. CABIN # 9 TAX PARCEL NO. 2469-072-02-006 LICENSED INSTALLER: HOWARD STEWART LICENSE NO. 61-97 PHONE: 970-963-8716 DESIGN ENGINEER: MCLAUGHLIN WATER ENGINEERS, DEAN DEROSIER PHONE NO. 970-925-1920 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: 1500 GALLON SEPTIC TANK WITH A 750 GALLON DOSING CHAMBER, 813 SQUARE FEET OF MOUNDED SYSTEM WITH 45 INFILTRATORS. SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN DATED 10-97 WITH THE FOLLOWING CONDITIONS: INSTALL A PUMP WITH VISUAL AND AUDIBLE ALARMS, ENGINEER RECOMMENDS A STAND-BY PUMP: MAINTAIN A 4 FOOT SEPARATION TO GROUND WATER: PUMP & FILL ABANDONED DRY WELLS :INSTALL PERFORATED PIPE ALONG THE LENGTH OF EACH INFILTRATOR TRENCH. ENGINEER IS RESPONSIBLE FOR FINAL INSPECTION. BUILDING TCO WILL NOT BE ISSUED WITHOUT ENGINEER CERTIFICATION. ENVIRONMENTAL HEALTH APPROVAL: DATE: OCTOBER 10, 1997 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS, CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 813 mound SQUARE FEET (VIA 45 infiltrator units ) INSTALLED 1500 septic TANK: GALLONS IS LOCATED DEGREES AND FEET FROM see site plan for locations. 1000 gallon dosing tank also installed. COMMENTS: Engineer as-builts received 1-23-98. ANY ITEM NOT MEETING REQUIREMENTS WILL.BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. ENVIRONMENTAL HEALTH APPROVAL /C1' DATE: Ja_nunry 26, 1998 SENT BY: 6-12-96 ; 11:12 ;CommunityDevelopment 9709251974;# 1/ 5 (Site Plan MUST be attached) rD ISDS Permit # l l j APPLICATION FOR INDIVIDUAL SEEPAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. 0. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (El Jebel) * PERMIT APPLICATION FEE $150.00 PERCOLATION. TEST FEE $200.00 * MAKE'ALI, REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" PROPERTY OWNER: /L„/ (lV PHONE: MAILING ADDRESS: G APPLICANT/CONTACT PERSON', QAWI�im ��,4 O PHONE: MAILING ADDRESS: LICENSED ISDS CONTRACTOR: W ;,� �6't.%A� PHONE: 6-26) 6 3 -j,1>716 COMPANY/DBA: ftj ADDRESS: PERMIT APPLICATION IS FOR: New Installation ( ) Alteration ( ) Repair LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Building Permit # (if known) Legal Description: Subdivision:) _- Filing: —Block-. Lot No. Tax Parcel Number: a_ -` - -1 Lot Size: Street Address: BUILDING TYPE: (Check applicable category) (7 Residential/Single Family ( ) Residential%Multi-Family* ( ) Commercial/Industrial* TYPE OF WATER SUPPLY ( ) Well V) ( .) Public Name *These systems ragkkira SIGNATURE: k,1,1-&,2$!�- (Check applicable category) Spring ( ) Surface of Supplier: Number Number Type — CC-3 al;l(!� of Bedrooms of Bedrooms design by a Registered Professional Engineer Date. 16 4 e _ TO BE COMPLETED Yb-�H; COUNTY lo,11/In1_3AMOUNT PAID: . RECEIPT #: � DATE: U CHECK # : CASHIER: Community Development Department (970) 328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 EAGLE COUNTY, COLORADO January 23, 1998 Karinga, LTD William Marano 7104 Frying Pan Rd. Basalt, CO 81621 Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 RE: Final of ISDS Permit #1733-97, Tax Parcel #2469-072-02-006. Property location: 7104 Frying Pan Rd., Basalt, CO., King Ranch Cabin # 9. Dear Mr. Marano: This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Janet Kohl Environmental Health Department Eagle County Community Development ENCL:Informational Brochure Final ISDS Permit cc: files Community Development Department (970) 328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 EAGLE COUNTY, COLORADO Date: October 10, 1997 TO: Howard Stewart Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 FROM: Environmental Health Division RE: Issuance of Individual Sewage Disposal System Permit No. 1733-97. Tax Parcel # 2469-072-02-006. Property Location: 7104 Frying Pan Rd., Basalt, CO. King Ranch cabins # 9& 10. Enclosed is your ISDS Permit No. 1733-97. It is valid for 120 days, The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County does not perform final inspections on engineer designed systems. Your TCO will not be issued until our office receives this certification. Permit specifications are minimum requirements only; and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files McLaughlin Water Engineers, Ltd., Dean Derosier MWE, LTD. McLaughlin Water Engineers Date: January 16, 1998 To: Eagle County Environmental Health Department - Heather S., Howard Stewart, and Karinga Ltd. From: Dean Derosier; McLaughlin Water Engineers, Ltd. RE: King Ranch # 2 - Septic System Design Notes - Barn and 2 Cabins This memorandum is to serve as the final inspection and certification notice to Eagle County that the Individual Septic System for the King Ranch barn and 2 cabins has been installed according to the design by McLaughlin Water Engineers and Eagle County Regulations. The system is complete and has been placed into service and is operating at this time. Attached is an updated asbuilt drawing of the system as it was installed in the field. Upon reciept of this memorandum, the final permit can be issued from your office for the system. If you have any questions, please feel free to call me. G. Dean Derosier, P. E. RECEIVED JAN 2 1 1990 kkt COUNTY COMMUNITY DEVELOOMNY MEMORANDUM DATE: October 2, 1997 TO: Worick and Bill - King Ranch\ Eagle County - Laura Fawcett FROM: McLaughlin Water Engineers, Ltd.; G. Dean Derosier,P.E. RE. King Ranch # 2 SEPTIC SYSTEM DESIGN - Barn, New Cabin, and Existing Cabin This memorandum is written to give you additional details on the design, materials, and installation of the Septic System which was designed to serve the proposed new barn and two cabins,(one new and one existing), which is being constructed on the property next to the Frying Pan River. The memorandum is separated into three sections; 1 - Septic tank and System design, 2 - Effluent tank design, 3 - Installation and Materials for the system. The design drawing is also attached for additional reference. 1. Septic Tank and Mound System Design: The location of the homes and the site conditions determined the required type of system which was to be designed. The site is located adjacent to the Frying Pan River, on a bench just above the river. The difficulties encountered deal with the limited area to work with and included the ground water level, existing water courses, and flat location for the system. These items lead to the design of a system which would use a standard septic tank and Mounded Infiltrator System, and will require a pumR to lift the effluent up to a flat area for disposal. � \�CVSR- The system design was based on the ultimate cons ction of a 1 bedroom residences for each of the cabins and 1 for the barn, fo 3�tal bedrooms, whic required at a minimum, the installation of a 1,500 gallon septic tank for the separation of solids an dosing tank. I recommend a 1,500 gallon tank as the main septic tank, and a 750 gallon tank as e effluent pump/dosing tank. The main septic tank is to be a double chambered tank and the effluent pumping/dosing tank is a single chambered unit. The two tanks are to be installed in a series with the septic tank first, followed by the effluent pump tank. The tank invert piping elevations are to be as shown on the attached design drawing or in the field as directed by the drawings. The water level, the dosing system, and the flow anticipated to utilized by the system determine the size of the Mound Infiltrator System required. Using 100 gallons per person per day and a peak factor of 1.75, a flow of 1,050 gallons per day requires 813 square feet of septic disposal in the System. Or 45 Infiltrator units in three trenches. 40 k� ; dp� i Yi ` The details of the Infiltrator System; installation, elevations, and location are shown on the attached design drawing and sheets. The overall system size will be 20-feet X 90-feet in three trenches. The distribution piping is to be SDR 35 sewer piping with a manifold at the trenches to evenly spit the flow. r Alk Effluent Pumping Tank: The effluent pumping tank is required to pump the effluent from the septic tank to the septic field in the terrace above the home site. The tank capacity is approximately 750 gallons. The tank was sized in order to get the required additional septic tank capacity and to cycle the pump operation of the system. The pumping system is required to pump the effluent up approximately 5-feet of elevation difference and 5-feet of piping and head losses, for a total of 10-feet of head at 40 gpm. The pump we have chosen for the system is a submersible, by Hydromatic Pump, Model number SD-25, a bronze pump system, with a piggyback float system. The pump is a .25 horse power, single phase, 115Volt unit, with a 2-inch discharge and a built in diaphragm level control system or optional float system to regulate the operation of the pump based on water levels in the tank. The pump operation and installation is simple, as the water level in the tan c rises it switches on the pump, which operates until it reaches the bottom of the pump and shuts the pump off. We recommend the operational float level system for the tank. A double float system will need to be used, also by Hydromatic, Model 3900. The pump is to set on the floor of the tank approximately 6-inch above the floor. (Design details for operational water levels in the tank are to be field determined by the design engineer. The type of pump control depends on the dimensions of the tank). At your option a second pump could be purchased as a backup or stand by pump. This would shorten the system down time and inconveniences which will occur if the pump breaks down or has other problems. The cost of the second pump is approximately $200.00. It is not required, but is recommended. '4 The effluent tank is also required by the County to be equipped with a high water level alarm system to alert you when a pump has failed to operate or another problem has risen. The high water level alarm system is operated by a float, mounted on the tank wall, which is activated when the water level rises to a chosen point above the normal operating pump level. The float signals a red light and a buzzer, which should be located in your adjacent mechanical room or garage. The buzzer can be turned off manually signaling acknowledgment of the problem, but the red light stays on until after the water level drops back down. This is a required safety feature which assists the owner in the satisfactory operation of system by letting you know you have a problem before it becomes an emergency situation. The system we have chosen is a Tank Alert 1. by S.J. Electro. (See design drawing for additional level control details. Please check to see if the existing alarm can be reused. 2 - 2-inch PVC conduits are required to be run from the adjacent home to the new effluent pumping tank. One is for power to the pump and the other one for the high water level control system. Please inform the electrical designer of the barn of these additions. Installation and Materials: The septic tanks can be obtained from Copeland concrete products in Rifle, or from the locally in Emma from Dreager. The tanks should be located as shown on the drawings and installed level. The access ports are to be sealed water tight and brought up to within 6-inches of final grade. If in the event the tanks are too high, minor landscaping may be required to bury them. The invert elevations for both tanks are critical to the operation of the pump and should be followed closely. The blockouts for the inlets and outlets are also required to sealed water tight to prevent infiltration. All piping, pump, and alarm system materials can be obtained form Dodson Engineering products in Glenwood or Grand Junction Pipe in Basalt. The 4-inch piping from the house to the septic tank and to the pumping tank is SDR 35. All Piping should be installed at a minimum depth of 3.5-feet with clean outs at all 90-degree bends and in line wyes at connects to main line. The pumping line is to be laid with the shown slope to permit the line to drain back into the tank after each pumping cycle to prevent freezing. The laterals are to be installed as shown on the drawing and are need to be installed to within + or - .01-feet. (See attached design drawing for bedding details and additional installation notes.) The septic system installation can be done by any excavation contractor who is familiar with this type of project. If you have any questions on the design or other items, please feel free to call me at any time. See installation and construction notes attached to this memorandum. CC: Icing Ranch - MWE - Denver ECEH Thanks, Dean Derosier ! MWE. LTD. McLauchlin Water Engineers Date: October 2, 1997 To: Eagle County Environmental Health & King Ranch From: Dean Derosier; McLaughlin Water Engineers, Ltd. RE: King Ranch # 2 - Septic System Design Notes - Barn and 2 Cabins The following are my design notes for the New Barn, New Cabin and Existing Cabin Septic System design. - 3 -Bed Rooms Total - one for each unit - Approx. 600 Square Feet of living area for each - 100 gallon per day per person - 10 minute per inch perc rates - Perc Test by GDD Use 15MPI for design - Ground water 5.0 feet from surface Tank sizing - 3 - Bed Rooms require a 1,500 gallon tank; Flow = Q = 3 bed rooms x 2 peo/br x 100 gal/day/per x 1.75 = 1,050 gallons per day Area of Septic field required = A A = (Q\5) x square roots of the perc rate (AVG) = 1,050/5 X SR(15) A = 813 square feet A = 813 Square Feet Infiltrators = 18 square feet = 45 infiltrators n.M 3 Trenches with 15 units is each trench - 10-feet apart. Ground elevation - 98.0 to 98.25 Ground water at 93.0 Invert elevation of trenches - 97.2 Add 18-inches plus of fill over top of infiltrators to allow 18-inches minimum cover over units. G. Dean Derosier, P. E. VENT 1411 SCREEN 24-" 0 MH RING � CQl/ER /7, ,..*1X ti q b £YE' 004T a. b• LIFT C,45LE , 4 x4" TEE"loo ¢ " PVIC 2 -2'1 PI/L' C191YO J/T OVICff _ + CDLIPUMG FROM SEPT/C — - -TO SPL/TACT? BOX T41VK IE= .47 -/OR sSEPT/G'' FIELD SCH =YC p I-1/6H WAT£R LEYE"L ' H/GH WXTER LEYEL FL0AT �'' ALARM SYSTEM D PUMP ON a FLDAT b a >Y , a P• /�UMPHrDf�DiYIAr�C SEE' /V1f-A049 R 00 WR OE'T.4/LS P a DRAIN HOLE AIMP OFF * /DOSING TA/Vff LE'YELS TA BeF/£LD D,-TE"RIWINIV gy •o..a DOSING TANK (NTS) E'd 6Z0'8Sb-68S 9N3 d31UM NI-lHsnu-ioW 8.E:9Z 86r 9? -inf, KING RANCH 8" October 1997 To: Patty Hadzley Eagle Cwnty Fax Number 970 329 71 RS Dear Ms Hadzley RE: PrRMIT APPLICATION - SEPTIC SYSTEM Reference is made to your conversation today with Mr W Morano, Manager of the Ding Ranch and your request to confirm in writing pertain aspects pertaining to the permit for the leach field in the lower field. Accordingly you are advised that the cabin will be hooked up to the existing septic systom which will lead into the now loach field In fulfilment of all of the iecent relevant and applicable code requirements as verified in your conversation with our Water Fmsinaer Mr l)c-.an Dernraiar In addition we confirm that the new cabin is emactly the same size as the cabin which war. destroyed and is being replaced. We trust that this completes all of your relevant inquiries. Yours faithfull % 416 le 401V k W5 cXHIM Lliuitad. Pcr: 7104 Frying Ilan Rosd %salt Colorado 8➢621 Phone (9701927 3132 P.3 GL. co' c NVIRONrvLENTAL HEALTH DEP.A.R.TMENT Property address Legal descriptio Property Owner: Name Address Phone Note: • Percolation Test Form, Site PIan and Grain Size Distribution Curve of the Sample must be submitted with this form. For all Lots <5 acres the site plan must include the entire lot. Test locations must be accurately tied to lot corners or other permanent markers. Location of perc and profile holes must be mapped adequately and identified with; stakes, flagging, etc. Profile holes must -be staked as #1, #2, and #3. Saturation • Smeared surfaces removed: Yes -K-No • Sand or gravel added: Yes . No • Date and dme presoak water added: /r/C/ y ,- C/ C) • Amount of presoak water added (gallons): • Date andpme percolation test is started: /al -;t-/-/ 7 / a : UCl • Did water remain in hole after the overnight swelling period: Hole I Yes No Hole 2 Yes JEINO o Hole 3 Yes Percolation Rate Measurement Percolation Rate (min./in.) Hole 1 f I Hole 2 0 Hole 3 Average / G roundwater: • Encountered @ ,Meet. • Estimated depth to maximum seasonal water table if not encountered in profile: Is area believed to be subject to seasonal fluctuations which could result in a seasonal water table within 8' of surface? _Yes No Slope determination in absorption area: % to the _—(direction) Bedrock: _ • Encountered @ feet. • Estimated depth if not encountered in profile: • Type of bedrock: Sandstone Claystone Silts Lone Other • Is bedrock fractured or weathered? Yes No • Is bedrock believed to be permeable? (Perc rate <60 min./in.) Yes No -------------- t P.4 Pofile Hole Information (Cont.) (Soils must be classified using Unified System ASTM D2487) Profile Hole Log 0 1 3 a� w .� 5 a 0 6 7 S 9 1-10 Certification A. / 0— /,:�-,I �r/Q 5 a/L I certify that the above information is correct and complete to the best of my knowledge and that all tests were performed in accordance with the provisions of County Health Department Regulation X by myself or under on. O 'gina ature Date Company Narrr6 Address -� ®��' a �• co ' 3 rMa .e. Phone Original Seal -, - •���------------------------------------------ _------------- c------------ P.. FG G £ G o c.� .� NENVjLON NTAL HEAL DEPARTMENT OMMINEPINO Percolation Test Result Form Hole Length of Water Depth Water Depth Drop In Percolation Hole Depth Interval @ Start Ca End Water Levef Rate t7a .Final No. (in.) (min.) of Interval of Interval (in.) Interval (in.) (in.) (min./in.) i 0 No '.- i'/ y /l / Cr 60 1 3�lG 3 Yz a-O � I 3 a yG a'3 S�Gc 3 -7 so / (� �r 3/ /33l �o �C" ' G �a ' G aU --- I a� Syr— /// _ 100 90 . 3 0 �6 a L_/ 0 5 �' �� —Iyz /9'VZ I 60 ate.--' ct G a--3 /L__--I /k/ 72e? Field Notes shall be recorded on this form or in this format; typed copies be submitted on this form. of field records may "A four hour test must be conducted unless (a) water remains in the hole after the presoak in which case one 30 min. interval is sufficient, (b) the first 6" of water seeps away in <30 minutes in which case a one -hour test of 6 - 10 minute time intervals may be used, (c) the .test is being conducted in sand in which case a one -hour test of 6 - 10 minute time intervals may be used, (d) three successive water level drops do not vary by more than 1/16 inch in which case a two hour test may be conducted. VV 1 VV V 1 "UV 1 V' UV 17VL11VV1IL111 "M G11 LI1V 1 1111 11Vi V I VVLV 1 V 1 `Y MVVE. LTD. _ McLaughlin Water Enginerrs Date; QctTo§r.r 8, 1997 To: Eagle County Environmental Health - Heather S. From: Dean Darosier; McLaughlin Water Engineers, Ltd. '3 REt: King R.-anRh # 2 - Styptic Systsm Design Notes - Barn and 2 Cabins The following are additional design notes per your request. 1. High seasonal ground water level - 5.0 feet frox surface y$kR:A(� 2. Dosing Tank - 750 gallons - Pump Hyda:oma.tic SD-25 10-foot TDH at 40 GPM Dosing vole to be approximately 200 to 250 gallons per dose 0V1- 9. Add 18-inches plus of fill over top of infiltrators to allow 18-inches minimum cover over units. Top 6" to be top soil over 61, of clay material over 6"plus of native material similar to that encountered during exaavat' a C af,03xe pzofile hole., Use material excavated at site for new cabin.�kK� 0� a. Existing dxywells to be abandoned - pump and fill with dirt.ov- 5. See attached section for more information on system design. G. Dean Derosier, F. E. OCT 0 81997 EAGLE COUNTY COMMUNITY DEVELOPMENT OU i -UC-`7 f NEI) 10 - U•J l ll1LrIUl(RL 11Y NEE I I:R LIIU 1 rtn INV, V e V'JL%) i 47 I •t � � v- r -� w Z m tj z x� M z c X r r r .,a f*1 C In X " I aGC3Z 4-�• t:j r� m <0 '0m0 ftm bd s� rn r 1 0 rn rn r R -� l� 1 m O i� it 0 - Vt3�< fq o- e� .a. <cl -n n -a9 - qzo z�d� r< rn rr1 Mxd M Cl < r" Vim- 1 -� � r -U L-1 8 �o1411 � T1 (PJ 6-11 M .,... .- . — ... .a.. 1IVL.AIWV1lLill TWII .Yl L.IlU . l n(1 LIV. 0(UOC-UIa1 4 r. ui 11NKLTD D .�_ _. A*LahiiWater EnginegfA Date: o-tober 10. LU7 fi_o : gagle C6unty Envi.ro,.=en tal health - Heather S . From: Deasy Derosier; McLaughlin Water Engineers, Ltd. RE: King stanch 4 2 - Septic System Design Notes - Earn and 2 Cabins The fcllowing additive design for the system, per your request. 1, A 1-1\411 perforated pipe shall b(& :Lnstal.led in each infiltrator trench system to aid in distriirutian. The pe=fforatioasa shall be 1-411 at 30" ors center located sin top of the pipe. The pipe shall be hung from the top of each infiltrator unit for the full length of the trench. G. Dean Derosier, P_ E. D N v b r 1597 To: Karinga Ltd. - Howard Stewart EXOm- Dean Derosier; McLaughlin Water Engineers, Ltd. $% King Ranch # 2 - Septic System Design Notes - Earn and 2 Cabins The Following additive design for the system, per our discussions, I. All Lines shall be installed a min of 3-5-foot deep and using a slope of 1.0% min. 2. Discharge line from the pump to the septic field shall be 1-1/2-inch diameter Sch SO Pvc, 3. Trenches shall be 8-foot on centers 4. Move septic and dosing tank to East end of Barn. S. Septio and Dosing tanks to be concrete. G. Dean Derosier, P. E. McLaughlin Water Engineers, Ltd. 210A Ventnor Ave., Aspen, Colorado 81611 (970) 925-1920 December 30, 1997 FAX (970) 925-1974 RONALD C. McLAUGHLIN LEO M. EISEL Janet Kohl - HALFORD E. ERICKSON WILLI" R. KENDALL RALPH L. TOREN Eagle County Environmental Health TERRENCE P. KENYON RICHARD E. McLAUGHLIN 500 Broadway GENE A.BURRELL Eagle, Colorado 81631 M'JOHNM:FLAUM MICHAEL IL GALUZZI SCOTT E. LEHMAN BRIAN S. KOLSTAD RE: King Ranch Septic System #2 G. DEAN DEROSIER EDWARD D. BAIN ISDS #1733-97 BRIAN E. CHEVALIER PAUL D. ZACHARY J. HAROLD ROBERTS LEANDER L. URMY DANIEL M. PETRAMALA RONALD D.LUCERO Dear Janet: Per your request, attached is an asbuilt drawing of the King Ranch Cabin Septic System #2 for your records. I have also noted cleanouts on the 4-inch services to each building, ties to the new 1,500 gallon septic tank and 1,000 gallon dosing tank, and field changes in pipe routing. To the best of my knowledge, these items should bring the new system into compliance with all Eagle County Codes, thus I am verifying that the system is installed according to the plans and specifications and memorandums of October 2,8,10. :%.d 0®v• 4 Please replace the original drawing with this one as it is representative of the field conditions. Very Truly Yours 44'�� 4� Mike Kelly McLaughlin Water Engineers 210A AABC Aspen, CO 81611 (970) 925-1920 Ph (970) 925-1974 Fax KingRanchPermit3\ 97-030.001\ cmk DENVER, CO PHOENDC, AZ (303) 45"550 (602) 466-2141 COMPLETE ENGINEERING SERVICES IN: WATER RIGHTS AND RESOURCES WATER TREATMENT AND DISTRIBUTION SUBSURFACE DRAINAGE IRRIGATION FOUNTAINS STORM DRAINAGE AND FLOOD CONTROL WASTEWATER COLLECTION TREATMENT AND REUSE FIRE PROTECTION WATER BASED RECREATION SPECIALTY HYDRAULICS RATE STUDIES AND UTILITIES ECONOMICS ..b VV VI IUL 1Q'UU 1lV"ILUUIIL.1l4 9YIILL.B. "JIU 1R!1 IYU, Q(VULUIQ I`; (� U1 NEMORANDIUM Doc umber a.Q, 1997 To; ,lanet Kohl Eagle County Environmental Health From: Mike Kelly McLaughlin Water Engineers RE: Icing Ranch Septic System 02 ISDS #1733-97 I am sending you via, mail a letter and asbu tt drwtiAng today. Our client has are interest in obtaining a CO or' TCO, as.we discussed in.our phone conve.rsatidn;. as soori as possible, thus I have attached .a cote' of the 1.e� ter. Please call with any questions_ You, R King anchPem.A6197-OD.CCV%emk 1/JJ-7/ lax if L40y-U/L-UZ-UUb KARINGA j S Y 6A NAME Cabins# 9+Ll •KING RANCH Basalt 2)�ti �S�il(L�ccc� JOB NO.IJ� JOB LOCATION BILL TO DATE STARTED S® DATE COMPLETED I Wall be 4ddie,s5-;1; ;A wri fly1�-i�� /ol 9 nud mkve-, i S SL4 e: � ID D LL BILLED '% � -1 " /-iGcl �14 7kz/"r r"-7 i JOB COST SUMMARY( r%23 q� 69 ffS TOTAL SELLING PRICE TOTAL MATERIAL TOTAL LABOR INSURANCE SALES TAX << s (2-��'. .�C�.o._ -- ��'f �. �,�. Lev � Isc. cos-rs TOTAL JOB COST �ase v6/a," GROSS PROFIT LESS OVERHEAD COSTS % OF SELLING PRICE 2 r� hu S� Ze /SDU __ dost'ctinip� = ZP, NET PROFIT _ c l� d /crv�+e, . _ I nc h/ 1 oles a�Gc�^ C f'J 1 �2 _ .Y� f ✓ �L G�O�s� v � (� �o has ViS[4tif ,�f'h(tii/1ir+f {f, _.��P�✓�%GY�d/.hGrlr.Gi kw cis, I I 00 0 U N � ,n G O � � U o 0 o �'' � 3 Printed in U.E . - - -__ = 3�_-_- _ _ - - - - _ - -_ - -. _ _ f .. _- .. ., _ - -. _ _ _ .. . , _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _ _, _ _ - _ .. _ _ -" 1 _ - _ _ _ - - - - _ _.. - - -_ — - - _ -- - - - - c _ s--- - _ _. - _ _ _ _ _ _ .. f - - _ - - - _ _ _ CHECK . E DATE 7 `� NUMBER INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, Colorado 81631 Telephone:328-8755 Repair Permit YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1 6 8 1 —0/ 1 Please call for final inspection before covering any portion of installed system. OWNER:Karinga Investments, Inc- PHONE: (970) MAILING ADDRESS: 7104 Frying Pan Rd. City: Basalt State: APPLICANT: Melinda COile,ggs PHONE: (970) SYSTEMLOCATION: 7104 Frying Pan Rd., Basalt TAX PZEL NUMBER:�2469-0072-02-006 LICENSED INSTALLER: 11 T KSKS-� ris Preusch &Vttj a -LICENSE NO: 40-97 DESIGN ENGINEER OF SYSTEM: McLaughlin Water Engineers, Dean Derosier 927-9927 CO ZIP: 81621 927-9927 / p� & / l -7 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: 15_00­GALLON SEPTIC TANK added to existing septic tanks down gradient from ABSORPTION AREA REQUIREMENTS: 5 4 7 - 5 SQUARE FEET OF SEEPAGE BED XXXX SQUARE FEET OF TRENCH BOTTOM. SPECIAL REQUIREMENTS: System installed prior to permitting. Install additional cabins 1500 gallon tank down gradient from the cabins. Contact the design engineer to certify proper installation of the tank as well as other system components. System to be finaled after en ineer certify cation is received b Eagle C unty E. H. ENVIRONMENTAL HEALTH APPROVAL: DATE: p Z// CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL TO AUTHORITY GRANTED IN 25- 10. 104. 1973, AS AMENDED. SYSTEM REGULATIONS, ADOPTED PURSUANT 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. AUTOMATICALLY BE A VIOLATION OF A 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. e INSTALLED ABSORPTION OR DISPERSAL AREA: 542.5 SQUARE FEET. Of f�o� INSTALLED SEPTIC TANK: 1500 GALLON DEGREES FEET FROM se asbuilts drawings for system locat SEPTIC TANK ACCESS TO WITHIN 8" OF FINAL GRADE AND PROPER MATERIAL AND ASSEMBLY YES —NO COMPLIANCE WITH COUNTY / STATE REQUIREMENTS: x YES NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS CORRECTED. COMMENTS: Engineer final certification received 10-2-97. ENVIRONMENTAL HEALTH APPROVAL: DATE: October 10, 1997 ENVIRONMENTAL HEALTH APPROVAL: DATE: (RE -INSPECTION IF NECESSARY) RETAIN WITH RECEIPT RECORDS APPLICANT / AGENT: OWNER: PERMIT FEE PERCOLATION TEST FEE RECEIPT # CHECK # q (Site Plan MUST be attached) ISDS Permi # APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. 0. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (El Jebel) * PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" ************************************************************************** PROPERTY OWNER: KAct-iNe-A LTD PHONE: RID MAILING ADDRESS: APPLICANT CONTACT PERSON- MEL *J" 'COt'-5s / / ' / /(�l,�r! �,tM,&" PHONE: d-10) 4 24 l`� Z:� MAILING ADDRESS: --- $At-01 LICENSED ISDS CONTRACTOR: COMPANY/DBA: ADDRESS: PHONE: ( ) **************************************************************** ********** PERMIT APPLICATION IS FOR: ( ) New Installation ( ) Alteration ( ) Repair **************************************************************** ********** LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Building Permit # (if known) Legal Description: Subdivision:1414-("OC44 Filing:_Block: Lot No. z Tax Parcel Number: -� -� �- rp Lot Size: 'Z6 AC-� Street Address: _-j l b' f' �R-�y� ►�4 aArJ �gsaK �ow+u►DQ *************************************************************************** BUILDING TYPE: (Check applicable category) Residential/Single Family (,s�} Residential/Multi-Family* ( ) Commercial/Industrial* TYPE OF WATER SUPPLY: (Check applicable category) ( ) Well Spring ( ) Surface 1 D1,In14 n nf gllpnl *These syst SIGNATURE: TO BE COMPLET AMOUNT PAID: Number of Bedrooms Number of Bedrooms Type e design by a Registered Professional Engineer Y THE COUNTY RECEIPT #: CHECK #: Date: DATE: _ CASHIER: Community Development Department (970) 328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 EAGLE COUNTY, COLORADO October 9, 1997 Karinga Investments, Inc. King Ranch Attn: William Marano 7104 Frying Pan Rd. Basalt, CO 81621 Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 RE: Final of ISDS Permit No. 1681-97, Tax Parcel #2469-072-02-006. Property location: 7104 Frying Pan RD., Basalt, CO. Dear Mr. Marano: This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your buildings may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Janet Kohl Environmental. Health Department Eagle County Community Development ENCL:Informational Brochure Final ISDS Permit cc: files Community Development Department (970) 328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 EAGLE COUNTY, COLORADO Date: September 19, 1997 TO: Howard Stewart FROM: Environmental Health Division Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 RE: Reiissuance of Individual Sewage Disposal System Repair Permit No. 1681-97. Tax Parcel # 2469-072-02-006. Property Location: 7104 Frying Pan Rd., Basalt, CO., King Ranch. Enclosed is your ISDS Permit No. 1681-97. It is valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County does not perform final inspections on engineer designed systems. Your TCO will not be issued until our office receives this certification. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files McLaughlin Water Engineers, Ltd, Dean Derosier, P.E. Community Development Department (970) 328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 EAGLE COUNTY, COLORADO February 18, 1997 Melinda Coils King's Ranch Manager P. O. Box 2433 Basalt, Co 81621 Dear Ms. Coils, Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 Thank you for calling the Eagle County Environmental Health Division this morning regarding the sewage smell complaint we are investigating at the King Ranch. Enclosed is an Individual Sewage Disposal System repair permit application. If this application is completed and returned to us by Wednesday February 19, 1997, we will waive the application fee. Otherwise, please include the $150 with your application. In accordance with the procedure outlined in the Eagle County Land Use Regulations (ECLUR), Section 4.03.06, "the Environmental Health Department may issue a repair permit and an emergency use permit to the owner or occupant of property on which a system is not functioning properly. ...The permit shall provide for a reasonable period of time, not to exceed 30 days, as provided by Section 25, Article 10-106(k), C.R.S. 1973, as amended, within which repairs shall be made. ...Concurrently with the issuance of a repair permit, the Environmental Health Department may issue an emergency use permit authorizing continued use of a malfunctioning system... Such an emergency use permit may be extended, for good cause shown, in the event repairs may not be completed in the period stated in the repair permit through no fault of the owner or occupant." After discussing the situation with you, coupled with the type of use, I believe that you will need to contact a Registered Professional Engineer to determine the extend of the repairs that are needed. Please keep the Eagle County Environmental Health Division informed of your progress in resolving your septic problems. Sincerely, Laura Fawcett Environmental Health Specialist cc: Raymand P. Merry, Environmental Health Manager James R. Fritze, Eagle County Attorney Community Development Department (970) 328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 EAGLE COUNTY, COLORADO Date: August 21, 1997 TO: Ute City Landworks Eagle County Building P.O. Box 179 500 Broadway Eagle. Colorado 81631-0179 FROM: Environmental Health Division RE: Issuance of Individual Sewage Disposal System Repair Permit No. 1681-97. Tax Parcel # 2469-072-02-006. Property Location: 7104 Frying Pan Rd., Basalt, Colorado; King's Ranch. Enclosed is your ISDS Permit No. 1681-97 being issued to address repairs needed at the above referenced property. You were notified in previous correspondence that alterations were initiated prematurely by your company as you had not obtained a 1997 Eagle County Systems Contractors License nor had there been an ISDS Permit issued for repair of the septic system. The design submitted by Dean Derosier, RPE, McLaughlin Water Engineers meets minimum regulatory standards but does not consider design features ;r.. recommended by Eagle County to achieve a higher quality wastewater, render more convenient access for inspection and extend the life of the system. Eagle County is permitting this system merely to document the existence of a system at this location which meets minimum standards. It is our understanding that a 1,500 gallon septic tank is proposed to be installed down gradient from the cabins. Please conduct this activity under the auspices of this permit which requires installation prior to December 1, 1997, and be sure it's proper installation is certified by Mr. Derosier. This will allow us to consider final approval of the system. Any changes in plans or specifications invalidates the permit unless otherwise approved. This System is designed by a Registered Professional Engineer and must be certified by the Engineer that the system was installed as specified. Eagle County does not perform final inspections on engineer designed systems but does issue final approval of the system upon engineer's certification. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements, especially as it relates to zoning. If you have any questions, please feel free to contact the Environmental Health Division at 328-8755. cc: files McLaughlin Water Engineers, Ltd., Dean Derosier Karinga Investments, Ltd. From: Heather L. Savalox To: LauraF Date: 2/25/97 3:12pm Subject: King's Ranch ** Proprietary ** Reply requested when convenient Dean Derosier of Mclaughlin Water Engineers will be dealing with this system. Not until the ground is ready for perc tests. She thinks one tenant left water running, causing the problem originally... not sure though. Seems to be improving since this person left. KING RANCH KARINGA INVESTMENTS LIMITED Ms. Laura Fawcett Environmental Health Specialist Eagle County PO BOX 179 Eagle,Co 81631 Dear Ms. Fawcett: Per our conversation on 2-25-97 1 am returning the completed application for a repair permit. Thank you for waiving the 150.00 application fee. We have discuussed the recent problems with an engineer and believe the problem to have been caused bV a tenant that has been running his water continually. We would like to see if the situation will improve now that the tenant in question has vacated the property. I live just below the leach field and the smell has been gone for about a week . The ground is also drying up. I will call you with the name of the engineer who did our percolation test as soon as I can get in touch with the owners of the ranch. We appreciate your continued patience and want to assure your department that we fully intend to comply with the community requirements. Thank you for your cooperation I will be in touch next week. Sincerely, Melinda J. Coile KING RANCH Manager: W Marano PO Box Number 1657 Basalt Colorado 81621 Department of Environmental Resources Eagle County Colorado To whom it may concern et al. RE: BEDROOMS AT KING RANCH Phone 927 3132 Fax — 927 9927 9P December 2000 I confirm the request for the following information received from John Plano, Eagle County Building Inspector (El Jebel Division): Cabin 1 1 Bedroom Cabin 2 1 Bedroom Cabin 3 1 Bedroom Cabin 4 1 Bedroom Cabin 5 1 Bedroom Cabin 8 1 Bedroom Cook house 1 Bedroom Mainhouse 2 Bedrooms Please note that all other bedrooms have separate septic systems. Mr. Plano made a request for details of a building described as Cabin 12. Please note that there is no building properly described as Cabin 12 on the property. There is a small storage unit which houses lockers for each of the tenants. It may be that this has been misdescribed as Cabin 12. I trust this assists with your enquiries. MWE. LTD. McLaughlin Water Engineers Date: May 1, 1997 To: Eagle County Environmental Health, From: Dean Derosier; McLaughlin Water Engineers, Ltd. RE: Kings Ranch Cabins - Septic System Design Notes The following are my design notes for the Kings Ranch Cabin Septic System design. This system is replacing the existing system which failed and was surfacing near cabin # 1. - 5 - 1 Bed Room Cabins - Aprox 750 Square Feet of living area in each SD - 75 gallon per day per person - 7.5 minute per inch perc rates - Perc Test by GDD - Ground water 8 feet from surface Tank sizing - 5 - 1 - Bed Room requires a 1,500 gallon tank; so the existing 3,200 gallons of septic tanks in series will work without modifications. Flow = Q = 5 bed rooms x 2 peo/br x 75 gal/day/per x 1.75 1,312 allons per day d K- Area of Septic field required = A A = (Q\5) x square roots of the perc rate (AVG) = 1,312/5 X SR(7.5) A = 718 square feet Infiltrator = 30% reduction F0 1Pi ���a A = 503 square Feet �r Infiltrators = 18 square feet = 28 infiltrators q -324 . 1 Gt ,� 5 4 Increase size of system td 35 units dd additional capacity tam, _.-- 5 units wide x 7 units long or- (15' x 2'�° G. Dean Derosier, P. E. I - -;A !1 X65 �z, 5 ��z•S 72 t { '254 ,2-0 S P. 3 �L� G�'r�tr�// I ENVI-KO;; ENTAL BEALTH DEPARTMENT Property address Legal description Property Owner: Address Phone Note: Percolation Test Form, Site Plan and Grain Size Distribution Curve of the Sample must be submitted with this form. n For all Lots <5 acres the site plan must include the entire lot. Test locations must be accurately tied to lot corners or other permanent markers. Location of pert and profle" holes must be mapped adequately and identified with l stakes, flagging, etc. Profile holes must be staked as #1, #2, and #3. turation • Smeared surfaces removed: Yes _.%.,,No • Sand or gravel added; ,Yes No • Date and 'me pr soak water added: y�/6121 7 0 • Amount of presoak water added (gallons): • Date an me olation test is started: Z/171Q-71!a 0 • Did water remain in hole after the overnight swelling period; Hole 1 Yes _2�_No Hole 2 Yes . X No Hole 3 ,_,_,_,,,Yes •„X_,z_No Percolation Rate Measurement Percolation Rate (min,/in.) Hole I —5 Hole 2 7 Kole 3 Zd_ Average % 5 C V LLUUH'it ECr: • Encountered @ Meet. Estimated depth to maximum seasonal water table it riot encountered In profiler • Is area believed to be subject to seasonal fluctuations which could result in a seasonal water table within 8' of surface? Yes No 7 %" 5 wg-s h i o Slope determination in absorption area:,,,% to the Le/_(direction) Bedrock: • Encountered @ — feet. • Estimated depth if not encountered in profile- 0'} • Type of bedrock; _Sandstone Claystone Silts Lone Other • Is bedrock fractured or weathered? Yes No up • Is bedrock believed to be permeable? (Perc rate c60 min./in.) XYes No P.4 Pottle Hole Information (Cont.) (Soils must be classified using Unified System ASTM D2487) — 4 Profile Hole Log 1 2 3 a' V ' 5 a 0 u 7 NJ 10 Certification << t �aC k C �� h �� S yri/5�•��-r-r�/ s S I certify that the above information is correct and complete to the best of my knowledge and that all tests were performed in accordance with the. provisions of County Health Department Regulation • X ' by myself or u e e ' ion. Ongina ignattare Date Company Name Address Phone Original Seal IMMUNOWSM P.S NF_M0 N'I`A_ & ;F6 DEPARTMENT UUMMMM��� Percolation Test Result Form Hale Length of Water Depth Water Depth Drop In Percolation Hole Depth interval Ca Start @ End Water Level Rate 0.fiinal No. (in.) (min.) of Interval of Interval (in.) Interval (in.) (in.) (min.An,) fo l6'ly l7Y2 3 4 �p !0 a�!`a � d � �r✓/tic �, a `l ,)-" 0 l5 5 /0 l -7 3l A'Ve, �� 'y5.7 t-71 7.3. 8 l7, 7. 'Field Notes shall be recorded on this form or in this format; typed copies of field records may be submitted on this form. ,_ c- 'A four hour test must be conducted unless (a) water remains in the hole after the presoak in which case one 30 min. interval is sufficient, (b) the first 6" of water seeps away in <30 minutes in which case a one -hour test of 6 - 10 minute time intervals may be used, (c) the test is being conducted In sand in which case a one -hour test of 6 - 10 minute time intervals may be used, (d) three successive water level drops do not vary by more than 1/16 inch in which case a two hour test may be conducted, UTE CITY LANDWORKS, INC. 2755 LOWER RIVER ROAD SNOWMASS, CO 81654 (970) 923-5157 phone/fag (970) 379-3399 fax SEPTEMBER 25, 1997 KING' S RANCH 7104 FRYING PAN ROAD BASALT, CO 81621 (970) 927-3132 Bill. (970) 927-4973 Warik. RE: PERMIT # 1681-97 Eagle County Environmental Health Division. Installation Cost to complete permit requirements. As per the letter dated August 21, 1997 it is apparent that Ute City Landworks, Inc. Has been given the requirement to install a 1500 Gallon Septic Tank at the Ranch. To date I have not received any design criteria as to the location of this tank from, McLaughlin Water Engineers, Ltd. The Permit requires this tank be installed prior to December 1, 1997. Due to the circumstances of this Summer. I am requesting Payment in full for the Tank Installation before I move in to do any further work. Estimated Cost for Tank Installation. $ 3,753.81 This Estimate is based on the following. 1. The Deposit is received no later than October 15, 1997 2. The Bridge can support a truck with a weight of more than 60,000 Lb. 3. A Design showing the exact location of the Tank. Should you hWtd. quest' s, Please give me a call. Sincerely, hrch Copies Sent: Eagle County, Environmental Health Division McLaughlin Water Engineers, Ltd. Dean Derosier KING RANCH 31d 4ugust 1997 Eagle County Community Development Environmental Health Division Fax Number: (970) 3287185 'To whom it may Concern, nu,w�,o L jl ,� �u,tititi l Z - CUA We have been attempting to ring your office today and have left a number of messages on your answer machine, to no avail. Would you please call Mr Bill Morano on (970) 9273132 at your earliest convenience. We anticipate your prompt response Yours faithfiilly. t'V, Morano, Manager 7104 Frying Pam Road Basalt Colorado 81621 Phone (970) 927 3132 1 In, AUTOMATIC COVER SHEET DATE. AUG-11-97 MQN 14:18 Kil FAX #. 197032871$5 FROM MCLAllGHLiN WATER ENG 03 PAGES WERE SENT (INCLUDING THIS COVER PAGE) 1IULnuunL111 WNIM UJU PHA NU. UfUyebly14 F. U1 McLaughlin Watet En 1eeis, Ltd. 210A Ventnolr Ave., Ashen, Colorado 81611 (970)'925-tad August 11, 1997 FAX (970) 925-1974 RONALD C. Md Au MIN LED M. E&AL LauraawCet HALPDRD L BRZCMK WIUJAM L KENDALL RAi PH L. TOREN Eagle Cowity Environmental Health RSJ- ,�.�M H 500 Broadway GENE A.SURML Eagle, Colorado 81631 MWER �,� MAW NEC1'IAEL R. J-.erTryas ECO" L LMMAN "MAN S, X014 M RE: King Ranch Septic System - Septic 'Tank Installation 0.DUN DIMA> BRIAN E. CHWALIER PALTL D. 24KARY Dear Laura: 1. HAROLDIDO RTS LEANDER'L. MfV VANJEL K PE] VULA RONALD D.LUCERO 1 am finally getting back to you regarding the septic system replacement for the Ding Ran.ch subdivision Lot 2, 5 cabins. You had several concerns on the system prior to final approval. I hope that I can address those here and we can get this project cleaned up and approved. 1. The existing sewer lines from the cabins to the existing tanks were replaced with SDR 35 fl- inch piping last fall. All the sewer lines coming from the cabins to the new septic field -are. 4-inch SDR piping. Sri. all the piping is new and meets required codes. ta existing tanks are single chamber tanks and they will remain. in place. The owner agrees u>7tp the taiaks on a yearly basis. ! 5ti����✓�- 3. A new 1,500 gallon two compartment tank will be installed on the line prior to the new septic field as shown on the drawing. The tar& is being located closer to the field due to limited room next to the existing cabins. This tank willalso slaw the flow down along the steep slope from ' the cabins, allowing better distribution in the field. I hope this covers all your concerns. Please replace the original drawing with this one as it is representative of the field conditions. After your review, please call so we can discuss the deficiencies .and make they ap. propriate additions and corrections needed to get this system approved. 925-1920 Very Truly Yours 11�cLa ter rs, L". 4,. G e er, KingF,anchr'ermit3197-022. 0011GDD D>zvv>sx cxr PNXNVcr AZ CQ7MTn,P.TP.. PN(:lh PF.RTN(3 $P,RVSCP:'•TNs WAMt R!(*MAMDMW)''lMCPS WATERTREATMU47ANDDEIVISLMON .SUDV,JR.FACEDLUNAM IMCfAT1OU fWNTALNS STORM DRAINAGE ANDTTIOM CpNPRoti WA,STEWATERCOI.1,F.CrCA1TREATM0'JT AND RWgF.. F)RERRCTikCnON WAP-ROAMORECREA71ON SPEI'3AL'9'1'HYDRAMiCS' RATED'IUDYES A:\DUSILICIL•S EGCk1C�MKti rluu-1 1-0 r I IVIN 1'i 1 r 17uLrlUUnL 111 WH I MK MNU V HA ICU. U ! Ude'D1 d (4 i. U;� ' . r 'y w� ) r LIZ, ! _ e � ".• 41+ j 1 i r rh K f ► McLaughlin Water Engineers, Ltd. 210A Ventnor Ave., Aspen, Colorado 81611 (970) 925-1920 May 1, 1997 FAX (970) 925-1974 RONALD C. McLAUGHLIN LEO M. EISEL HALFORD E. ERICKSON Eagle County Environmental Health WILLIAM R. KENDALL RALPH L. TOREN 500 BroadwayTERRENCE P. KENYON RICHARD E. MCLAUGHLIN Eagle, Colorado 81631 GENE A. BURRELL MICHAEL E. MERCER JOHN M. PFLAUM MICHAEL R. GALUZZI RE: King Ranch Septic System Permit SCOTT I- LEHMANBRIAN S. KOLSTAD G. DEAN DEROSIER EDWARD D. BAIN Dear Heather: BRIAN E. CHEVALIER PAUL D. ZACHARY J. HAROLD ROBERTS LEANDER L. URMY ALA I am addressing this letter to you as I do not know who the actual contact is on this system. DNIEL M. RONALD D LUCE O Please forward this letter to the appropriate officer, thanks Dean. I have attached the design drawing, design notes, and percolation tests for your records. I was contacted by the owner of the King Ranch Cabins to review a failed septic system just prior to leaving on vacation. Upon arriving on site, raw sewage was running on the ground and immediate action needed to be taken to stop the flow and the hazard created by the flow. I performed a percolation test on the site immediately with the help of the owner and a backhoe. I designed the system to meet Eagle County Codes from the what I could remember on site. I then left on vacation and told the owner that I would handle the design submittal to the County when I returned as this situation needed immediate attention. The owner proceeded with installing the system as soon as he could get the materials and a contractor on site. Upon my return, I inspected the work installed to date, and found that the system was installed according to my design and comments by an unapproved contractor in Eagle County, Ute City Excavation. If you need a licenced contractor, Ute City will need to get approval or a different contractor will need to be contacted to complete the nearly completed work. Please let me know which is the best route to take on this item. Please call if you have any questions, 925-1920. Very Truly Yours McLau hl' r 'nee Ltd. G. e rosier, KingRanchpermit\ 97-022.001 GDD DENVER, CO PHOENIX, AZ (303) 458 5550 (602) 468-2141 COMPLETE ENGINEERING SERVICES IN: WATER RIGHTS AND RESOURCES WATER TREATMENT AND DISTRIBUTION SUBSURFACE DRAINAGE IRRIGATION FOUNTAINS STORM DRAINAGE AND FLOOD CONTROL WASTEWATER COLLECTION TREATMENT AND REUSE FIRE PROTECTION WATER BASED RECREATION SPECIALTY HYDRAULICS RATE STUDIES AND UTILITIES ECONOMICS May 8, 1997 Eagle County Environmental Health 500 Broadway McLaughlin Water Engineers, Ltd. 210A Ventnor Ave., Aspen, Colorado 81611 (970) 925-1920 FAX (970) 925-1974 RONALD C. McLAUGHLIN LEO M. EISEL HALFORD E. ERICKSON WILLIAM R. KENDALL RALPH L. TOREN TERRENCE P. KENYON RICHARD E. McLAUGHLIN Eagle, Colorado 81631 GENE A. BURRELL MICHAEL E. MERCER JOHN M. PFLAUM MICHAEL I,GALUZZI RE: King Ranch Septic System Permit E. BSCOTT RIANS. KOLSTLEHMAN G. DEAN DEROSIER EDWARD D. BAIN Dear Laura: B AU E. CHEVALIER PAUL D. ZACHARY J. HAROLD ROBERTS LEANDERL.URMY. Thank you for your comments and concerns per our conversations earlier this week I am DARONALNIEL M. P D. LUCELA , RONALD D.LUCERO resubmitting the septic system replacement for the King Ranch Subdivision Lot 2, 5 cabins. I have included additional information that will help you get a better overall picture of the existing system as well as the new field installed. This is a asbuilt of the system as it stands today. I will also address your concerns per our conversation. 1. The scale of the drawing is i" = 40' 2. The existing tanks are single chamber tanks. 3. The service lines from the cabins flow into the 4-inch line that connects the tanks as shown on the drawing. tU$uv? 4. Tanks are approx. 10-feet from the cabins. 5. I have added cleanouts and line dimensions 6. I have added a detail of the system layout and the flow distribution lines to the infiltrators. 7. The legal is Lot 2 of the King Ranch Subdivision. 8. I have added several known dimensions to ponds and water courses. Please replace the original drawing with this one as it is representative of the field conditions. After your review, please call so we can discuss the deficiencies and make the appropriate additions and corrections needed to get this system approved. 925-1920 Very Truly Yours McLa hl' ate En ' s, Ltd. rosie , E KingRanchpermit2\ 97-022.001 GDD MAY 1 3 1997 EAOL9 COUNTY COMMMItY 08VELOPMENT DENVER, CO PHOENDC, AZ (303)458-5550 (602)468-2141 COMPLETE ENGINEERING SERVICES IN: WATER RIGHTS AND RESOURCES WATER TREATMENT AND DISTRIBUTION SUBSURFACE DRAINAGE IRRIGATION FOUNTAINS STORM DRAINAGE AND FLOOD CONTROL WASTEWATER COLLECTION TREATMENT AND REUSE FIRE PROTECDON WATER BASED RECREATION SPECIALTY HYDRAULICS. RATE STUDIES AND UTILITIES ECONOMICS McLaughlin Water Engineers, Ltd. 210A Ventnor Ave., Aspen, Colorado 81611 (970) 925-1920 11, 1997 FAX (970) 925-1974 RONALD C. McLAUGHLIN LEO M. EISEL Laura Fawcet HALFORD E. ERICKSON WILLIAM R. KENDALL RALPH L. TOREN EagleD County Environmental Health TERRENCE P. KENYON RICHARDE.McLAUGHLIN 500 Broadway GENE A. BURRELL Eagle, Colorado 81631 MICHAEL E. MERCER PFLAUM MICJOHNHAEL UZZI SCOTT E. LEHMAN BRIAN S. KOLSTAD RE: King Ranch Septic System - Septic Tank Installation G DWADD.BAIN BRIAN E. CHEVALIER PAUL D. ZACHARY Dear Laura: J.HAROLDROBERTS LEANDER L. URMY DANIEL M. PETRAMALA RONALD D.LUCERO Per your request, attached is an asbuilt drawing of the King Ranch Cabin Septic System for your records. I have also noted existing access\inspection ports on the septic system, cleanouts on the main 4-inch line and on the 4-inch services to each building, ties to the new 1,500 gallon septic - z tank which has been installed and approved by MWE. To the best of my knowledge, these items should bring the new system into compliance with all Eagle County Codes, thus I am verifying that the system is complete. Please replace the original drawing with this one as it is representative of the field conditions. Very Truly Yours VcLan at gi td. e ' , P. KingRanchPermit3\ 97-022.001\ GDD DEN W CO PHOENIX, AZ (303)458-5550 (602)468-2141 COMPLETE ENGINEERING SERVICES IN: WATER RIGHTS AND RESOURCES WATER TREATMENT AND DISTRIBUTION SUBSURFACE DRAINAGE IRRIGATION FOUNTAINS STORM DRAINAGE AND FLOOD CONTROL WASTEWATER COLLECTION TREATMENT AND REUSE FIRE PROTECTION WATER BASED RECREATION SPECIALTY HYDRAULICS RATE STUDIES AND UTILITIES ECONOMICS it)01-V/ laxif ,'4b9-U/2-02-006v LOt#2, King Ranch KARINGAJ JOB NAME 71-0-4--=Frying--pan . Basalt, CO 81621 JOB NO. B LOCATION bl'�aj 2co LL, IN00CA BILL TOIN-All -/u DATE STARTED a a3�g7 DATE COMPLETED DATE BILLED Gv. , %i � � �, ` ` �� JOB COST SUMMARY TOTAL SELLING PRICE TOTAL MATERIAL TOTAL LABOR i INSURANCE SALES TAX g dajj`e �VIIN7 MISC. COSTS ��.�i��17 ��Z�Gic � `i.O �-Cu��t-- >-i✓� `f /��Uc -��-�CL�.. I; .{ TOTAL JOB COST 11�lca ° o GROSS PROFIT LESS OVERHEAD COSTS % OF SELLING PRICE G xw-i.t/v 7(CI NET PROFIT JOB FOLDER Product 278 ®@ NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MA 01471 JOB FOLDERU.S.A. Printed in . _ _ �- �- _ - _ - _ . __ ,�-- -- . ._P_ 1 _ - - _ - f - F `_ - _ - - _ _ - _ _ __ j -. - - - - f � - _ i F _ _ - _ - - f i I 4 _ _ � _ 1 - I t I - - i{tF ' _ t ` t - __ - I - 4 - i_ I i = _ I - - .. - [ - - - _. _ _. _ _ I - - - - - _ - � - _ _ � _ k � _ _ __ ' _ •- - � �- -- - _-_- � - _ _ _ _ � _ _ _ _ _ _ _ __ _ _ _ _ - _ _ _ - - - ��_ _ - .__._. _ _�__ - _-3. - _. ._ _ _ _ _ _ _ _ _ _ __ _ _ - -_ _ _ _ _ _ _ _ _ _ _____ _ - _ _ - _ - _ _ _ _ _ _ s �' _r -�. -.-_ �.z - _ - - - _ _ - -_.. __ �.. _ _ _ _ � _. _ _ _ _ �. � _. _ _ - _ _ _ _ _ _ _ _ _ _ -rf� - - INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. REPAIR PERMIT 1843-99 ORIGINAL PERMIT 1733-97 OWNER: KARINGA LLC PHONE: 970-927-2093 MAILING ADDRESS: 5901 FRYING PAN RD., BASALT, CO 81621 APPLICANT: DONALD E. BARNES PHONE: 970-97-2093 SYSTEM LOCATION: 7104 FRYING PAN RD. CABINS 6 & 7, BASALT, CO TAX PARCEL NO. 2469-072-02-006 LICENSED INSTALLER: KING RANCH MANAGEMENT, DONALD BARNES LICENSE NO. 22-99 PHONE: 970-927-2093 DESIGN ENGINEER: McLAUGHLIN WATER ENGINEER, DEAN DEROSIER PHONE NO. 970-925-1920 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR CABINS 6 & 7, AND THE MAIN HOUSE 2-1250 GALLON SEPTIC TANKS 1116 SQUARE FEET OF ADDITIONAL ABSORPTION AREA VIA 36 INFILTRATOR UNITS IN A TRENCH CON- FIGURATION, AS PER ENGINEER'S DESIGN REVISIONS DATED 10/26/99. (35 INFILTRATOR UNITS IN A BED CONFIGURATION EXISTS TO PRO- VIDE 651 SQUARE FEET OF ABSORPTION AREA.) TOTAL SQUARE FOOTAGE OF THE LEACH FIELD WILL BE 1767. SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN REVISIONS DATED 10/26/99, AND DESIGN MEMORANDUMS DATED 10/18/99, AND 10/25/99. INSTALL ADDITIONAL AREA IN TRENCHES IN SERIAL DISTRIBUTION. INSTALL CLEANOUTS BETWEEN THE TANKS AND EACH OF THE BUILDINGS, AND INSPECTION PORTALS IN EACH TRENCH. MAINTAIN A 6 FT SEPARATION BETWEEN EACH TRENCH AND THE EXISTING LEACH FIELD, AND BE SURE TO RAKE ALL TRENCH SURFACES TO PREVENT THE SMEARING OF SOILS. ONE OF THE NEW TANKS IS TO SERVICE CABINS 6 & 7, AND THE OTHER ONE IS FOR THE MAIN RESIDENCE. DO NOT BACK FILL ANY PART OF THE INSTALLATION UNTIL THE ENGINEER AND EAGLE COUNTY ENVIRONMENTAL HEALTH HAVE INSPECTED THE SYSTEM. THE ENGINEER IS RESPONSIBLE FOR FINAL CERTIF ST N. ENVIRONMENTAL HEALTH APPROVAL: DATE: OCTOBER 26, 1999 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WI ALL REQUIREMENTS OFHEEAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS, CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND MAY RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 1116 SQUARE FEET (VIA 36 7NFTT,TR ATOR TTNT TS ) INSTALLED CONCRETE SEPTIGANK: 1250 GALLONS IS LOCATED _ DEGREES AND _ FEET FROM CABINS 6&7 INSTALLED CONCRETE SEPTIC TANK: 1250 GALLONS IS LOCATED _ DEGREES AND _ FEET FROM MATN TTnTTSF. SEE AS —BUILT DRAWING FOR SYSTEM COMPONENT T.0CATTnNS, COMMENTS: ENGINEER FINAL CERTIFICIATION AND AS —BUILT DRAWING RECEIVED JUNE 2, 2000. ANY ITEM NOT MEETING REQUIREMENTS WILL BE COR$EC-T-E-B R FII��IT OVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. ENVIRONMENTAL HEALTH APPROVALDATE: JUNE 8, 2000 Incomplete Applications Will NOT Be Accepted ('Site' Plan MUST be attached) DONALD E. BARNES 5901 Frying Pan Rd. Basalt, CO 81621-9724 970-923-2093 ISDS Permit # ��`'�� C1 Building Permit # APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. O. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (El Jebel) * PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 * * * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" PROPERTY OWNER: �/ P, (ti C A [-LC- MAILING ADDRESS: 5401 F -110a PAU fi0 • � LKALLCO g'Glt PHONE: APPLICANT/CONTACT PERSON: DOAJAL' E. 6'°MArar 14t. PHONE Alo) q2-j-2-053 LICENSED SYSTEMS CONTRACTOR: i)oNALb PHONE: COMPANY/DBA: �,wc, QANc-K KkANA(-V4U I" ADDRESS: 5-901 FEY" ?4'u 4�&A-24LK Co *************************************************************************** PERMIT APPLICATION IS FOR: ( ) NEW INSTALLATION ( ) ALTERATION ()0 REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description: I(L«'C, 2AUCA SUADM560.) [ter 1 4 LOT Tax Parcel Number • 240 Z Lot Size: 41. C�`% A� Physical Address: 1i 04 Fp-yi.414 P" Pb- ;6ftSALX- CO. &I(OZI BUILDING TYPE: (Check applicable category) (1) Residential/Single Family Number of Bedrooms I glqvv� (4) Residential/Multi-Family* Number of Bedrooms ( ) Commercial/Industrial* Type TYPE OF WATER SUPPLY: (Check applicable category) ( ) Well K Spring ( )' Surface ( ) Public Name of Supplier: *These systems require desiSill by a Registered Professional Engineer SIGNATURE: ***************** AMOUNT PAID: Date : Z2 �� RECEIPT #: DATE: _ HE #: CASHIER: 1 Community Development Department (970)328-8730 FAX (970) 328-7185 TDD (970) 328-8797 Email: eccmdeva@vail.net http: //www.eagle-county.com June 8, 2000 Karinga LLC Donald Barnes 5901 Frying Pan Road Basalt, CO 81621 EAGLE COUNTY, COLORADO Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 RE: Final of ISDS Repair Permit #1843R-99, Tax Parcel #2469-072-02-006. Property location: 5901 Frying Pan Road, Basalt, CO. Dear Mr. Barnes: This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Janet Kohl Environmental Health Department Eagle County Community Development ENCL: Informational Brochure Final ISDS Permit cc: files Community Development Department (970)328-8730 FAX (970) 328-7185 TDD (970) 328-8797 Email: eccmdeva@vail.net http: //www.eagle-county.com EAGLE COUNTY, COLORADO Date: October 26, 1999 TO: King Ranch Mangement Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 FROM: Environmental Health Division RE: Issuance of Individual Sewage Disposal System Permit No. 1843-99. Tax Parcel # 2469-072-02-006. Property Location: 7104 Frying Pan Rd., Basalt, CO., King Ranch cabins 6 & 7, and the main house. Enclosed is your ISDS Permit No. 1843-99. It is valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County does not perform final inspections on engineer designed systems. Your TCO will not be issued until our office receives this certification. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files McLaughlin Water Engineering, Dean Derosier September 16, 1999 Dean Derosier McLaughlin Water Engineers 111 P AABC Aspen, CO 81611 Re: King Ranch Septic Mr. Derosier: Via fax: (970)925-1974 & mail In review of your design notes for the King Ranch ISDS the following revisions must be made to your proposed designs. This is to comply with the State of Colorado's Guidelines On Individual Sewage Disposal Systems written by the authority of the Colorado Department of Health and the Water Quality Control Division. As you know, Eagle county will not permit distribution boxes or a bed design for infiltrator systems. Those items were installed at the King Ranch in 1997, before the Environmental Health Division issued the permit, and no inspection was able the be performed before the bed was backfilled. - The distribution box must be removed from the design and all of the trenches need to be serially distributed. The bed configuration will not be permitted for the addition. There will have to be trenches which maintain a six foot separation. The trenches must be serially connected to the existing bed. If you have any questions call me the Environmental Health Division at (970) 328-8755. Sincerely, Michele Curran Environmental Health Specialist cc: Bill Moreno -King Ranch iR ► Community Development Department (970) 328-8730 FAX (970) 328-7185 TDD (970) 328-8797 Email; eccmdeva@vail.net hctp: //www.eagle-councy.com EAGLE COUNTY, COLORADO March 11, 1999 Donald Barnes, Manager King Ranch 7104 Frying .Pan. Rd. Basalt, CO 81621 Dear Mr. Barnes, Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 As per our telephone conversation March 4, 1999, 1 am returning your $60.00 check for the repair permit at the King Ranch, in cases where repairs are voluntarily initiated, the $150.00 fee for a repair permit is waived. I have also enclosed a copy of our first correspondence with Mr. Moreno. Please re -read this letter as it reiterates some important points regarding this septic failure at the King Ranch. As we discussed, it is essential that you contact a registered professional engineer to submit a septic system design to our office as soon as possible. According to Section 4.03.1.0, Chapter IV of the eeulations, "...no permits shall be issued for the following systems unless they are designed by a Registered Professional Engineer..,systems which service commercial, biLsiness, institutions, industry, or multi -family dwellings." Please be advised the state Water Quality Control Division would need to be involved should your system's design exceed 2,000 gallons per day. We look forward to receiving an engineer designed submittal and an accurate site plan so that the repair permit can be issued to you in a timely fashion. Please call us at (970) 328-8755 should you have any questions regarding this matter. Thanks for your. cooperation. Sincerely, Heather Sava.lox, REFIS Environmental Health. Specialist II encl Received Sep-08-99 10:39am from CCITT G3 a ENVIRONMENTAL HEALTH page 1 From: Mowbray Solicitors To: Mishel Curran pate: 918199 Time: 11:43:1 a AM Page 1 of 4 f ACSIMILE COVER PAGE To: Mishel Curran From: Mowbray Solicitors Sent ; 918199 at 11:41:54 AM Pages: 4 (including Cover) Subject ; Attention. Mishel Curran From Bill Marano. Phase find following copy of letter from McLaughlin Water Engineers as promised, I will contact you as soon as you are available to answer any other questions, I trust this is satisfactory, Thanking you in anticipation of your assistance. Bill Marano. 1 --, may• 1L�im vrriiGn mivuai IS1Uy2bl914 i Oct-12-99 12:45PM; Page 2/14 1 do not have a problem with using, trenches for the final addition to this system, as per my memurandurn, that is the current design for the final addition to this system. I« addition, the flow can be easily serial distributed through the trench system per your requirements, and I will make this change. Intermixing serial distribution between bed systems and trench systems is also not recommended, buta line wild be run into the bed system at lower corners, 'l will add this in the final design. I will make the changer to the drawing, to reflect the redesign per my Dcsign Memorandum dated September 7, 1999 and per this letter and send the new drawing to you to review. Tease call if you have aaiy questions Sincerely Yours, McLaug W . r i s td. G. sn 1 ier, Cidd/97-022.0 I /king#K --••- �7 ......rr.v v�..-+.• vvrv�Lll LIV1..1..1} 17l uthdo I t6/4 ; UCT-12-UY 12:45PM; Page 3/14 McLAL Gl:l1.JNi WATER ENGINEERS, lt& 111 P AARC ASPEN, COLORADO 8 16 1 L 970-925-1920 970-925-1974 fax mwera"n@rof.nel. MEMORANDUM Date: Se{atc,uber_ y_ 1999UPDATED OCT OBER 11, 1999 ;�j,�d`'v To: Fagle County Environmental: health - King Ranch i Frouy: Dean nernsier; NlcLhughlin Water Engineers, Ltd. FIE: King Ranch - H'innl Septic System Addition Design i�intrs Aijst'he following arc my design aiotcs for the Final Additiai�to . c Selrtic 'ystcn, at the Ki. T1iesystem proposed is to treat. the eight cabins and the 3 bWr om Mai louse: remodel. Cuu c;abirls ltluough 5 and ti 8 (6 bedrooms), arc vrt the recently(1997) install system in front of thouse. C abins 6 rand 7 (1 bcdTOorns)amui th tnaii � ,c;-is_ are on a, old tank sat are failing. All of the cabins, l - 8, are b oortt u�1it+�1. This ac.i.12n will complete the sepr�lacement at the King Ranch, cis all oi'the existing buddin& and 17ropc�.�ed remodelon new 1�t14' .i VSt£Y/15'. 1tt is proposed in this Project to design a systtmi that caai handle all of the existing cabks(1-8), (8 bedrooms), and the remodel of the main. horne,(3 bedrooms), or 11 bedr4xlm9 total. The existing system installed in 1997 is 35 in. utrators, (7 rows of units) sized for 6 bctlrou,ns. 'Thus the new systen is to :add enough capacity for 5 additional bedrooms. For the Design I started the calculations from scratch. Thu following is a summary of the design. R cabins = 8 bedrooms plus main hon1.L of 3 bedrooms (remodel in Future) or 1 I Lutal. - 75 gallon per day per person - 7.511inutc per inch pert rates - Perc Test by GDD - Ground water K feel. from surface Average Flow = Q — # brs X # 2pco/br X 75 Q = 11 x 2 x 75 = 1,650 gallons Design Flow or Max blow = Qmax =1,650 x 1.50 = 2,475 gallons per day. '1 �,uik sizing - 11- Bed Rooms rvqu.ires a 1,093 gallons of storage; ('i 'utic 1.25 X Qmax) = 2,450 x 1.25 = 3,093 r'ryt Gil CIVUO, la/uyec)] U14 ; UCCT-12-99 12:45PM; Page 4114 Tank Dcsign - 3,093 gallons are needed. The existing tank is a 1,500 gallon tank. Tlure are 2 - 1,000 gallon, (tanks b and c) and 1 - 1,250 gallon, (tarik a)thitt are single chwnbered tanks that scree cabilis 1-5 and # 9, total 3,250 gallons, (7 ote: the single chambeLgr� tanks will r,at he ineluei'ed rn the reyrlirecl or•rigrs volume this is per a vonversatiun with Heather al lsclOc" County dyring the: initial desijyn wo kl, These are also tied in series into the existing 1,5oo gal lcm. 1 propose to install a now 1,250 gallon tank for the two newt' cabins bcing added, (9 6 and 7) and a new 1,250 gallon tank for the proposed main house remodel: Tliis would prclvidc 4,000 gallons of storage for the i 1 bedrooms, not including; the, single chambered tanks.' �1✓ The cffiuent from 1,250 tank from the cabins 6 raid 7 ould tic into the main effluent Iine above: the 1,500 gallon tank as would the effluent from tho new 1,250 tank from the main house. This would create a ,cries of tanks with the 1,500 gallon existing tank acting as a flow equalizer prior to flows entering the disposal field. The existing sputter box will be used to take the flow equally to the 7 rows of clr.<uubQrs in tha bed systemi and 5 rows of trenches as discussed below. 1'hc length orthe field is short onough to not.rcquire the infiltrators be feed frcirn both ends. Area of Septic field required = A A = (Q15) x squs,rc roots of the pure rate (AVG) = 2,47515 X SR(7.5) A = 1,350 square; feet 15.5 sy, ft per unit 30% reduction for infiltrators - 950 square fcct or 62 infiltrators The existing field is 35 writs, 7 rows of 5 units in a bed type system. 62 total - 35 existing - 27 additional units required The design would add additional 30 units to even out the trencli lcrrbths. I propose to 15 additional rows of trenches of 6 units or 30 infiltrators for a total of 65 units, (note - only 62 required). 1 rcconunend three trenches to be ad&-d to the east side of the existing and two trenches to be added to the west side of the existing systc3r. See dv:5]gii drawing for more information. Abandoned and remove existing System, tanks, acid piping for the; two cabins and th.c existing main house. Dispose of per Eagle County Rogulations, All invert elevations and final locations on both systems to be field detennined by the Engineer. Match I]E of existing system and piping. All piping to be SDR 35 PVC. Install new splitter box outside 1,500 gallon tank with 4 outlets as shown on the drawing. Pour conerete pad under the new splitter box to prcv;mmt settlement. pump all cxisting trunks prior to placing two new tanks on litre. Existing piping fiom the 1,50.0 gallon tank to the infiltrators will nce,dto be repiped to work with the splitter box and other system additions. Received Sep-08-99 10:39am from CCITT G3 4 ENVIRONMENTAL HEALTH page 2 From: Mowbray Solicitors To: Mshel Curran Date: 918199 Time: 11:43:16 AM Page 2 of 4 Sent By: MCLAUGKIN WATER ENGS; 10709251074 ; SOP-8-90 10:09AM; Page 1/5 MoLAi.JGID-IN WATER ENGYMEERS, ltd. 1 I I F AA14C A3F'F.Pd, COI.MaWo 91011 970-925.1920 970.925-1974 ruA mwruslran(r wr.siet MEMORANDUM M Date: Seutetnber,7,1999 To: Eagle County Environmental Health - King Ranch From: bean Derosier; McLaughlin' Water Engineers, Ltd. RL- King Ranch - Final Septic System Addition Design Notes Ttie following are my design notes for the Final AddidoP 10.d,w Soptia Systwrt at Oro Kie{g Itiuizh. 'I he systurn proposed is to treat the eight cabins and the 3 bedroom Main house retnodel. Currontly the cabins 1 through 5 and #i 8 (6 bedrooms), are on the recently (1997) installed system in front of the main house. Cabins 6 and 7 (I bedrooms)and the main houso is a 2 bedroom unit, are on a old tank system that are tiling. All of the cabins, 1 - 8, are 1 bedroom units. Tlsts design svill come&A— the .sc C)V& ".U., 1 Lsrnstat # the Mhg flanaks a Qf the exisnng bgiULngs and to� elv will be n o .sWU0 g4tems. It is proposed in this projoct to design a systorn that can %andk. 01 orthe existing cabins(14), (8 bedroots), and the remodel of tau: main home, (3 budruoms), or 11 bedrooms total. The existing systcrt► installed in 1997 is 35 infiltrators, (7 rows of 5 units) sized for 6 bedrooms. Thus the now system is to add enough capacity for 5 additional bedrooms. For the Design I stated the calculations I'rorn scratch. The: following is a summary or the design. - $ cibins = 8 bedrooms plus main home of 3 bedrooms (remodel in (inure;) or l I total. - 75 gallon pcVr day per person. - 7.5 ni nute per hich pert: rates - !'erc Test by ODD - Ground water 8 fact from surface Average Flow = Q m # brs X # 2pwlbr X 75 Q= I 1 x 2 x 75 = 1,650 gallons Design Flow or Max Flow = Qrnax =1,650 x 1.50 - 2,475 gallons pi,-r day. o Tank sizixte - l l - Bed Rooms requires a 3,093 gallons of storage; ('yank - 1.25 X Qn-tx) - 2,450 x 1.25 - 3,093 2 Received Sep-08-99 10:39am from CCITT G3 a ENVIRONMENTAL HEALTH page 3 From: Mowbray Solicitors To,. Mishel Curran Date: 918199 Time:11:43:16 AM Page 3 of 4 Sent 9y: MCLAUaHLIN WATER ENOS; 19700251074 ; Sep-S-00 10:09AM; Page 2/6 Tank Design - 3,093 gallons arc n"-.dcd, Thu existing tank is a. 1,500 gallon tank. There are 2 - 1,00o gallon, (tanks b and 0 and 1 - 1,250 gallon, (tattle Qthsit are single chambered tanks tbat serve cabins 1-5 and # 8, total 3L250 gallons. rl&k,tf1g sr!!e chambered ttanlis will not be iri-au, ir: the re f{e ire stckra a Mluaie, this is Percover a.'ota with Heather at Zazlo C-oynty, d King the iniria ctasi n w rk . These are also tied in series into the existing 1,500 gallon. I propose to install a new 1,,250 gallon tank for the two new cabins being added, (# 6 and 7) And a new 1,250 gallon tank for the proposed main house remodel. This would provide 4,000 gallons of storig f l 1-bedrooms, not including the single chainbersd t wks. The effluent !Torn 1,250 tank from the oabim 6 and 7 would tic into the nnain ottltwnnt ling above tlno I,Soo gallon tank as would the effluent from the new 1,230 tank Isom the ntiain house. This would create a series of tanks with the 1,500 gallon existing umik acting as a flow equali2.ar prior to flows entering the disposal field. A spliUur box would be installed just prior to the field wero 4 c#ilu47rt ln'ic Arould take thr, flcsw Gqually to the 13 rows of oht►mbors as discussed below. The 1%m th of tho field is short enough to not require the infiltrators be food from both ends. Area, of Seotic fig E=ircd = A L A = (Q\5) x square roots of the pare rate (AVG) = 2,475/5 X 5R(7,5) A = 1,350 squ= feat o 15,5 sq, ft per unit I 10% reduction for infiltrators — 930 square feet or 62 infiltrators— b F i The existing field is 35 units, 7 rows of 5 units in a bed type system, i S 62 toted - 35 existing 27 additional units required The design would add additional 30 units to evert out the trench lengths.. 1 propose to a 5 additiommall .rows of 6 units or 30 infilnators or 65 total units. 3 rows to be added to the east side of'the existing and 2 rc.)ws to be added to the west side of the existing systenn. , tw dLNign drawing for more information, Abandoned and remove existing system, tanks, and piping tier the, lwo cabins and the existing inewn honsc. Dispose of per Eagle Cotunty Regulations. All lnvcrt clovations and final locutions inn both systeinns to be field dt;tvtmined by the Engineer. Match 1R of existing system and piping. All piping to he SDR 35 PVC. Install new splitter box outside 1,500 gallon tank with 4 outlets as shown can the drawing. Four concrete pad under'tho new spiiitar box to prevent settlement. Pump all existing tanks prior to placing two new tanks on line, existing piping from the 1,500 gallon tank to the infiltrators will need to be ropipO to work with the new splitter box and other system additions. 3 rrom: mowpray Soucaors i o: r asnei kxrran oats: 8tt5/W Tune: 11.43:15 AM Page 4 of 4 a3 Sent By: MCLAUGHLIN,WATEA GNGSi 19709261974 i Sep-8-99 10f10AMi Page 3/5 Place gt;ogrid fabric on bottom of each trench prior to setting infiltrator units to aid in. settlement reduction, Min covor over units is 42" and approximate dimensions are 30' X 36'. Mound slightly over top of compietod systc-m. All piping to be 4" SDR 35 PVC. Tlie Tank will be in,tilled in the general area below the l umv. Compact botc. excavated for tank prior to setting tank. Tees will be installed on both tlw inftlucnt and effluent lines of the tank, set on the inside of the tank. Set top of tine from tee within l" of the roof of the tactic and extend line downuard 12" below center line of tees. Pill tank with water prior to backlill to check for teaks and leave water in tank for placing the svAerti in service. Sceptic taroks will be: a two-chambcrt d tanks with ucccss ports within C" of final 'emdo, System distribution is through a splitter box to divides flow cvc my bctwcm each line to each and of infiltrator units. Compact area and r b1dittwfr box and place a shoe:t nfgw'igrid fabric prior to setting box. The regulations require that the system bu rrvir-tive d by the State or Colorado oycr 2,000 gallons or now. Average flow front this system is calculated to be 1,650 gallons. The flow 2,475 gallons if'you use the t? flow x 15U% = Qmax. We can ruduco the numbor and size of the new tanks if the single, chttrnWrcd lathes are included in the flow calculations. T would prefer not to use a new drawing for tba design, as part of this design intcgmtcs tha entire icing Ranch System, and we arc upgrading and expanding the: existing symm of tanks, Iines, and disposai fields. Using the existing mapping allows us to sera the King lL mch System as a whole, G. Desch D" 97 0 . 11gddPig4 v McLAUGHLIN WATER ENGINEERS, ltd. 111 P AABC ASPEN, COLORADO 81611 970-925-1920 970-925-1974 fax mweaspen@rofnet MEMORANDUM Date: May 25, 2000 To: Pitkin County Environmental Health, From: Dean Derosier; McLaughlin Water Engineers, Ltd. RE: King Ranch - Frying Pan River - Eagle County - Phase 3 Septic System Cabins 1-8 and Main House System Permit Awamw The addition to the King Ranch Cabins 1-8 and the Main House septic system has been installed by Don Barnes and placed into service. MWE and GDD have inspected the installation of all of the systems and find they were installed according to MWE's design and ECEH requirements. This letter is to serve as the acceptance letter for MWE and recommendation to Eagle County for final acceptance of the system. I have attached a set of record drawings for your information and records. The asbuilts include the Barn system installed in Oct. of 1997, the original system for cabins 1-5 and #8, and the new addition for cabins 6 and 7 as well as the main house. The final system consists of 4,000 gallons of double chamber septic tanks and 3,250 gallons of single chambered tanks, (single chambered tanks are not included in the design calculations). A 1,250 gallon tank is located on the Main House as well as for cabins 6 and 7. A 1,500 gallon tank is located on the main line just prior to the disposal system to serve cabins 1-8 and the Main House. The existing septic field consists of 35 infiltrators in a bed system of 7 rows of 5 units in each row. To the East side of the bed system 3 trenches, 14 infiltrators, were added. 1 trench of 4 units and 2 trenches of 5 units. These 3 trenches were added to the system through serial distribution. On the West side 4 trenches were added to the bed system through serial distribution, 22 infiltrators. 1 trench of 6 units, 1 trench of 7 units, 1 trench of 6 units, and 1 trench of 3 units. The asbuilt drawing shows the -- installation location of each trench. Each trench is set 6' from the adjacent trench and bed system, with serial distribution between the trenches and bed system. Trench lengths vary to meet site conditions and keep system out from underneath the roadway. A total of 71 infiltrators have been installed for the cabins 1-8 and Main House. have any questions. D. -4 Derb e� P. E. &. , \fnl\97 e 0 MWE McLAUGHLIN WATER ENGINEERS, Ltd. 111 P AABC ASPEN, COLORADO 81611 970-925-1920 970-925-1974 fax mweaspen@rof.net MEMORANDUM Date: September 7 1999• UPDATED OCTOBER 18 1999- FINAL DESIGN NOTES To: Eagle County Environmental Health - King Ranch From: Dean Derosier; McLaughlin Water Engineers, Ltd. RE: King Ranch - Final Septic System Addition Design Notes�ro� The following are my design notes for the Final Addition to the Septic Syster�t at the King Ranch. The system proposed is to treat the eight cabins and the 3 bedroom Main house remodel. Currently the cabins 1 through 5 and # 8 (6 bedrooms), are on the recently (1997) installed system in front of the main house. Cabins 6 and 7 (1 bedrooms)and the main house is a 2 bedroom unit, are on a old tank system that are failing. All of the cabins, 1 - 8, are 1 bedroom units. This design will complete the septic system replacement at the King Ranch as all of the existing buildings and proposed remodels will be on new septic systems This system design is based on phone conversations with Ray Merry and Heather Savalox. It is proposed in this project to design a system that can handle all of the existing cabins(1-8), (8 bedrooms), and the remodel of the main home,(3 bedrooms), or 11 bedrooms total. The existing system installed in 1997 is 35 infiltrators, (7 rows of 5 units) sized for 6 bedrooms. Thus the new system is to add enough capacity for 5 additional bedrooms. For the Design I started the calculations from scratch. The following is a summary of the Final System Design. - 8 cabins = 8 bedrooms plus main home of 3 bedrooms (remodel in future) or I I total. - 75 gallon per day per person - 7.5 minute per inch perc rates - Perc Test by GDD - Ground water is — 6.5 feet from surface at the center of the system. Average Flow = Q = # brs X # 2peo/br X 75 Q = 11 x 2 x 75 = 1,650 gallons Design Flow or Max Flow = Qmax =1,650 x 1.50 = 2,475 gallons per day. Tank sizing - 11- Bed Rooms requires a 3,093 gallons of storage: ('Tank = 1.25 X Qmax) = 2;450 x 1.25 = 3,093 led in August of Tank Design - 3,093 gallons are needed. The existing tank is a 1,500 gallo�ta that arelsingle chambered1997. There are 2 - 1,000 gallon, (tanks b and c) and 1 - 1,250 gallon, (tank a) ambered will that that serve cabins 1-5 and # 8, total 3,250 gallop Lonversation with Hehather at EaglesCoun not. durin included in the required story a volume the initial design work). These are also tied in series n1eaddedtl(# 6 and gl,500 and a propose to I tank sfor lthe new 1,250 gallon tank for the two new cabins being 000 gallons of storage for the 11 bedrooms. not proposed main house remodel. This would provide 4, including the single chambered tanks, which is more than the required 3,093gallons and with the single chambered tanks provides ample storage of solids. ine ve 1,500 The effluent from 1,250 tank from the the ne`6112d7 would tie into the main effluent 0 tank from the main house.Thislwouldoecreate series gallon tank as would the effluent from the n tank acting as a flow equalizer prior to flows entering the disposal of tanks with the 1,500 gallon existing field. The existing splitter box will be used to take the flowequally on each side will be fed through serial the 7 rows of chambers in the fisting bed system. From the end of the bed system the ne distribution lines as discussed below. Area of Septic field required = A A = (Q\5) x square roots of the perc rate (AVG) = 21475/5 X SR(7.5) A = 1,350 square feet ch system; the USING - 1 infiltrator = 15.5 sq. ft and a 30%reduction isi ivem;for infiltrators used in a tren additional area or # of infiltrators needed is as follows: The existing bed system is 35 units, 7 rows of 5 units in a bed type system, or 542.5 sq ft. (No reduction for infiltrators is ven for a bed system). subtract 30%reduction 1,350 sq ft (required) - 542.5 (existing) = 807.5 sq ft; for infiltrators = 5 7 65 s additional area needed. 65 s ft/ sq ft /unit = 36 infiltrators required gG j^ `d 5 q a e len se to a ional rows The design would add additional 36 units to even out the trench I recomnie id three trenches to be added to he f trenches of 6 units or 36 infiltrators for a total of 71 units. east side of the existing and three trenches to be added to the west side of the existing system. See design drawing for more information. Abandoned and remove existing system, tanks, and ing for the two cabins, 6 and 7, and the existing main house. Dispose of per Eagle County Regulations. All Invert elevations and final locations on both systems to be field determined by the Engineer. Match lE of existing system and piping. All piping to be SDR 35 PVC. Connect to the existing splitter box outside 1,500 gallon tank with 2 outlets as shown on the drawing. Pour concrete pad under the s g eprlbog to fr prevent settlement. Pump all existing tanks prior to placing two new tanks on line. Existin i in from the enches will need to be repiped to work with the splitter box and 1,50U gallon tank to the new infiltrator tr the bed system. 7 e Place geogrid fabric on bottom of each trench prior to setting infiltrator units to aid in settlement reduction. Compact area under splitter box and place a sheet of geogrid fabric prior to setting box. Min cover over units is 42 and approximate dimensions on each side are 20' X 36'. Mound slightly o �r top of �f completed II system. All piping to be 4" SDR 35 PVC. New trenched to be 6' apart minimum.- The Tank will be installed in the general area below the home. Compact holes excavated for tank prior to setting tanks. Tees will be installed on both the influent and effluent lines of the tank, set on the inside of the tank. Set top of line from tee within V of the roof of the tank and extend line downward 12" below center line of tee. Fill tank with water prior to backfill to check for leaks and leave water in tank for placing the system in service. Septic tanks will be a two -chambered tanks with access ports within 6"of final grade. box to divide flow evenly between each row in the bed system. The System distribution is through a splitter new trenches shall be serial distributed with a line from the end of the last infiltrator in the bed system at each corner to the end of the first trench on each side. I would prefer not to use a new drawing for the design; as part of this design integrates the entire King Ranch System, and we are upgrading and expanding the existing system of tanks, lines, and disposal fields. Using the existing mapping allows us to see the King Ranch System as a whole. G. Dean Derosier, P. E. o 25002 0 3 � � 0j'� � .. ..... ........... - ". - .. ............ .............. ....... . . ..... .... .. . T1,9110MI'm•A". Wl"Wi"MI-911-1 . .......... ... ...... ....... . ..... . . . .... .... ...... ....... .. ........ ... . .. .... ... ...... ........... ... . ... ... .... .... ........... -:: . ........ ..... .... ...... .. .... ...... .... . . . .. ............. ......... . . ... ... .. ............ ....... ..... .......... ... .. ... n(--r_=' -1 OC3C3 -rl ll� . .. .... . .. .. ............... .... ..... . ...... oct-H-o3 01:07pm From -Eagle County Clerk El Jebel 9709632396 T-962 P.02/06 F-254 �r. Laughlin Rincon ongineerin+J design consulting I1�P'AASC +���0816i1 970-M-1920 970»925-1974 t sr� gnat MMIOXAMItum— J�' 1♦1U1lRR3Ridddtl,I O F-WeCO QUAY EUVYmmept'd RUM —Ray Merry s n — ���iE#ies 31,04 Frying Pau Rad t OVA Ray tiw:ks for taking the dme to talk tome about the King Bch Addition.- ThisL 1t��` our conversation dealing with adding an additional bedroom to the main King Ranch house at 7104 Frying Pan Road. Ply mview'Your it # 1943-99 for the orighW system► notes, design and asbuilts. Tlie following arc any design nottes for the Main I< wov Addition to the Sep& System at tin King Ranch. The system proposed is to frost the eight cabins and the 4 bedroom Main hoarse. Curilendy the cabins 1 through 5 and # S (6 bedroom aj Cabins 6 and 7 (1 bedrooms) and the main house (3 bedroom), are an tha 1999 system in ft nt ofthe main house. The 1999 syift m was designed to serve 11 bedrooms and consists of 71 infilEtrators laid out acc ord`ng t D fhe at ached asbuilt drawing in a bad and trench layout. Some over sizing was done in 1999 to provide for standard tank sizes and even length ovac1es. It is proposed in this ice.jea to design a drat can hmadle all ofthe eating cabins (1-8), (8 bedrooms), and the remodel ofthe man horde to a 4 bedroom, or 12 -bedrooms total. The following is a. sumr lmy of Me Find System Design. - 9 cabins = 9 bedrooms plus mails home of 4 bedrooms or 12 total. - 75 gallon per day per person - 7.5 minute per inch perc rates - Pem Test by ODD - Ground water is — 6.5 feet fimm surface at the center of the system. Average Flow = Q = # brs X 0 2perbr X 75 J Q =12 x 2 x 75 —1,890 gallons t j, , I la Wo Design Flow or Max Flow = Qum ,i B x 1.50 = 2,700 gallons l � . ' or� G�%�'' Tan-12- Bed Rooms requires a 3,375 gallons of storage; ° t�D ker � A, �+0 S (Tank =1.25 X Qmax) - 2,700 x 1.25 = 3,375 S r n r � �'�1,� Gloms off'SL7aL. fll^'T_0_0Inri7 I l=n fi"J' . ra7dM TM. rne'l 177 e'rll Ik I-rW l7kll 1 1-IrFU TI 1 Oct-08-03 01:08pm From -Eagle County Clerk El Jebel 9709632396 T-962 P.O3/06 F-254 Tank Design - The existing tanks total 4,000 gallons and are in and 1-1,500 gallon,) that are single chambered tanks. The 4,000 tied in ns series, exceedsthe are2 -1,250 gallon, gallon storage volume, so no now tanks am need m.g required 3,375 prOposed. deal r work in 1999 The effluent lotat 1,250 tank froxiri the cabins 6 and 7 ties into the main effluent line' above the 1,500 gallon tank as does the effluent from the 1,250 ft* from the main house. c This us a series of tankse with the 1,500 gallon existing tank acting as a flow equalizer prior to flows encoring e a disposal flank. The existing sputter box will be used to ticks the flow equally to the 7 rows of ehumbera in the original bed system. From the end of the bed system the trenches installed in 1999 are feed through serial distribution lines and the new infiltrators or trenches am to be added to *0 ends ofthe Serial j�EstrihutEon trenches. of pgj field required = A 2Q 33 system A — (W) x square roots Of the pert rate (AVG) = 2,700/5 X SR(7.5) A =1,479 square feet S6�o USING I infiltrator = 15.5 sq. ft and a 3�reduction is given for infiltrators used in a trench system, the additional area or # of infiltrators needed is as follows. Note the'original bed system of 35 in units did not receive a 30�10 reduction in size for the use of infiltrators, so the size of this system is subtracted offthe total square footage: required prior to applying the 30•io reduction for infbrators in a trench system. The original bed system is 35 units, 7 rows of 5 units in a bed type system, or 542.5 sq ft. o educti n for infiltrators is given for a bed sy eM) The 1999 system added 36 m(ft infiltrators for 71 total units. 2003 system - 1,479 so ft (required) - 542.5 (existing bed) a 936.5 sq ft, subtract 30sio reduction for use of infiltrators = 656 sq & additional area needed. 656 sq fV15.5 sq ft /unit = 43 infiltrators required. 36 were installed in 1999. So 7 more infiltrators am required for a total of 43 infiitMp? s in the UrInCh system and 77 total for the hers an.i irpnn:. The design would add additional 7 units to each end ofthe system to even out the trench lengths as shown on the drawing. i recommend 7 units to be added to the western end of the existing, 3 on the existing row and 4 in a new trench. See design drawing for more information. Place gedgrid fabric on bottom of each trench prior to setting infiltrator units to aid in settlement reduction. Min cover over units is 24". Mound slightly over top of completed system. All piping to be 4" SDR 35 PVC_ l used the original asbuilt drawing for the new drawing for the design, as part of this design integrates the entire King Ranch System, and we are upgrading and expanding the existing system of tanks, lines, and disposal f el Using the existing mapping allows us to see the King Ranch System as a whole. G. Dean r 3-43-0l lgddladditiondsgn Dept of Community Development Eagle County Bumming P.O. Box 179, Eagle, Co. 81631-0179 Att: Colleen K. Wirth Building Inspector Dear Colleen, Re: Application BP-15311 Robyn Lawry long Ranch 7104 Frying Pan Road, Bs 11% Co.81621 Ph: 970 927 4973 Fax 970 927 3383 RECEIVED OCT 2 b 2004 EAGLE COUNTY COMMUNITY DEVELOPMENT I submu0ed tits above bull ft permit but it was declined due to the existing septic system on our properly. We are worift on a new plan for a complete new septic system. John Piano (prior io his departure) suggested I write this letter to get an Aide ion of our permit while we sort this out. Would you please make a note on our fie. Should you hm a any questions, please do not hesitate to oor-tort me. Yours sincerely, Robyn Lawry King Ranch Management 5901 Frying Pan Road Basalt CO 81621 (970) 927-2093 December 22,1999 Environmental Health Division Community Development Department Eagle County Building, P.O. Box 179 500 Broadway Eagle CO 81631-0179 TO: Environmental Health Division RE: Sewage Disposal System Permit No. 1843-99; Request for extension Delays in delivery of equipment and materials necessary for excavation, construction and installation and the onset of Winter conditions has prevented the completion of the project under the referenced permit. The steep terrain, frozen ground and inclement weather conditions will prohibit any significant progress until the April or May thaw. An extension in time for ISDS Permit No 1843-99 is hereby respectfully requested. If the break in weather in the Spring follows a normal course, we should safely complete the project prior to the end of May, 2000. Si rely, l n t�..�. cam.-•., Donald E. Barnes, Applicant Cc: McLaughlin Water Engineering William Carlson BP 13796 From: Laura Fawcett To: Janet Kohl; Ray Merry; William Carlson Date: 8/2/01 9:23AM Subject: BP 13796 They want to add a garage out at King Ranch up the Frying Pan and I know that they have had septic issues due to site constraints, so i thought we should discuss this further. I'II ok for a site plan at the Building Division. i A,Q-,�( 9 R-49" (9- c Oct-08-03 01:07pm From -Eagle County Clerk El Jebel 9709632396 T-962 P.01 F-254 -- -- -- -✓ --- — • ..v.4 AL —%_'Vul 11 l lvl I Mailing Address: 0020 Eagle County DrivF El Jebel, Colorado 8 102�': Phone: 970-704-278� Inspection line: 970-704-278r- Fax: 970-704-278C El Jebel —Monday/ Wednesday/Friday Eagle —Tuesday/Thursday Fax Transmission Date: / U - 6,•(-J_S From: John Piano Phone: 704-2784 To: �,� eT - Company: Fax: -3 Phone: Number of pages including this cover page. If all pages have not been received; please call (970) 704-2784. Thanks! rr•r r. r..�r» i.irr, r.• .. rs�rr.•i -r r-,. rF.ri 1— r�r7� �� irt.� r� n � i �rr.i -r� � Aff<�'ild -A- f AJL-w i S D S A)b Pam' &CI O 1 0 2461-07 a-02 -oo-(6 -.�C,cNrIE,C t2 R 57— 5 3 ni V"-7-' mm4 TI Ir If M. f571lm Tm. rn! f r F`ent IkITV rkll I IJrrll -r" 11AF'r. ^i Send Confirmation WorkCentre 450c report for ENVIRONMENTAL HEALTH 3280349 May-25-99 09:22 AM Successful Pages scanned 5 Pages confirmed 5 Job Sent To Remote Station Duration Mode Pages Results 789 May-25 09:20am 1 970 248 7198 02:25 ECM C 5/ 5 OK,96 $$$ Phone charge code F Forward P Poll 48 4800 bps chosen A Auto -distribute G Group dial PC to/from PC 96 9600 bps chosen IRM C Cover page ECM Error Correction M Mailbox PW Password 144 14400 bps chosen Receive to memory U Ww to WQhgl_ Howl na 4 YQM�t (ad( me ov 01-1 W/QUeS-hmg ��` C� re� n d MWE MCLAUGHLIN WATER ENGINEERS, ltd. 111 P AABC ASPEN, COLORADO 81611 970-925-1920 970-925-1974 fax mweaspen@rofnet MEMORANDUM Date: April 14, 1999 To: Eagle County Environmental Health & Don Barnes - King Ranch From: Dean Derosier; McLaughlin Water Engineers, Ltd. RE. King Ranch - Final Septic System Addition Design Notes The following are my design notes for the Final Addition to the Septic System at the King Ranch. The system proposed is to treat the eight cabins and the 3 bedroom Main house remodel. Currently the cabins 1 through 5 and # 8 (6 bedrooms), are on the recently (1997) installed system in front of the main house. Cabins 6 and 7 (2 bedrooms)and the main house is a 2 bedroom unit, are on a old tank system that are failing. All of the cabins, 1 - 8, are 1 bedroom units. This design will complete the septic system replacement at the King Ranch, as all of the existing buildings and proposed remodels will be on new septic systems. It is proposed in this project to design a system that can handle all of the existing cabins, (8 bedrooms), and the remodel of the main home,(3 bedrooms), or 11 bedrooms total. The existing system is 35 infiltrators, (7 rows of 5 units) sized for 6 bedrooms. Thus the new system is to add enough capacity for 5 additional bedrooms. The following is a summary of the design. - 8 cabins = 8 bedrooms plus main home of 3 bedrooms (remodel in future) or 11 total. - 100 gallon per day per person - 7.5 minute per inch perc rates - Perc Test b0yGDD Ground water 8 feet from surface��XL70�^" ` Tank sizing - 11- Bed Rooms requires a 3,610 gallons of storage; (Tank = 1.25 X Q) 3500 Flow = Q =11 bed rooms x 2 peo/br x 100 gal/day/per x 1.75 = 2,888 gallons per day. 2-000 3t�oo �a�-- The existing tank is a 1,500 gallon tank. There are 2 - 1,000 gallon and 1 - 1,250 gallon single chambered tanks that serve cabins 1-5 and # 8. (Note: the single chambered tanks will not be included in the required storage volume). These are also tied in series into the 1,500 gallon. I propose to install a new 1,250 gallon tank for the two new cabins being added # 6 and 7 and a new 1,250 gallon tank for the proposed main house remodel. This would provide 4,000 gallons of storage for the 11 bedrooms. The effluent from 1,250 tank from the cabins 6 and 7 would tie into the main effluent line above the 1,500 gallon tank as would the effluent from the new 1,250 tank from the main house. This would create a series of tanks with the 1,500 gallon existing tank acting as a flow equalizer prior to flows entering t disposal field. � ���,,Q 'YW 14 Im i� J(JlJ« A splitter b� would be installed just prior to tmberseas discussedld were 4 fbelow,line would take the flow equally to the 14 rows of cha The length of the field is short enough to not require the infiltrators be feed from both ends. Area of Septic field required = A A = (Q\5) x square roots of the perc rate (AVG) = 2,888/5 X SR(7.5) A = 1,581 square feet 15.5 sq. ft per unit 30% reduction for infiltrators = 1,106 square feet or 72 infiltrators The existing field is 35 units, 7 rows of 5 units in a bed type system. The addition would require and additional 37 units, I propose to a 7 additional rows of 6 units or 42 infiltrators or 77 total units. 3 rows to be added to the east side of the existing and 4 rows to be added to the west side of the existing system. See design drawing for more information. Abandoned and remove existing system, tanks, and piping for the two cabins and the existing main house. Dispose of per Eagle County Regulations. All Invert elevations and final locations on both systems to be field determined by the Engineer. Match IE of existing system and piping. All piping to be SDR 35 PVC. Install new splitter box outside 1,500 gallon tank with 4 outlets as shown on the drawing. Pour concrete pad under the new splitter box to prevent settlement. Pump all existing tanks prior to placing two new tanks on line. Existing piping from the 1,500 gallon tank to the infiltrators will need to be repiped to work with the new splitter box and other system additions. G. Dea a s'er E. 97-030.01\gdd\king#3 �. ' .,>:; ;� ` ,:�, ��y Y� Y �� IaX 1fZ40!)-U/Z-U2-006 Lot #2, King Ranch KARTNGA JOB- NAME, -T-E04—Fry—ing p-a—n BAsalt, Co 6wd 4�. di1flf,f;-%, I,., f I JOB NO, 10 DATE STARTED 31l DATE COMPLETED DATE BILLED IIIE40 FOUR RAW W$1116M FIVINIF&I'v"M ,A4 I MIA WO 14 4 :t �W&21 .............. , L4,mtp � 6,.il �, -I A-4-k JOBF;7 t2eeN —1 / - jo_,C e_y I C, 4-0 FC)rJ WKD�� q12-6 Aou+ bo-l-l-tslrn C)� UC,Ck-� e a j< -, a5S JOB FOLDER I S -k 4 (11-5 " 6 P11— +t -j,, -.1— ��/d� - p� A�• P t In USA SIt Q 0fig !r j 7, S i cJ' d /o/s� .3 — f ll, i�5 L�-� o✓�-�,"� bESlu� LLW� r9 7 G� C�iS ;,—� �S-u;— -l'C� ��,,.,.Lv',�' .�fj �j t /' /� -ivy`-l�.L /mow r -i-- ��%'AiH S iJ��L� /`Pil'�^-O✓!� �YI.Q /4'i�ZJ��- / ,�.�,. p-yt-Q �� ��r�- et�e ,% � ��t v! l� `s � is Gw✓�r�,. �D % � / �i.` �k *"•G y "'C +,�.p�"^� �'1.6Y`,J %��� G(,e'� Lv i�� cT. �W �.t�S Ors LLLGfrY+�r�..-aG�p� Gt.II O �? � etc; �.t't✓,1 //� 1 ..y/� A-V 45 3 rA- '-,4 '17, 6'7Z' WoLj o� Is ,. { Jl It I Pod-conswner _. - _ E _- f E F _ ` �. � _ _ - - _ _ r _ - _ _ k _ _ _ k _ j - - - I E _ _ _ 't f _ - - - _. _ . ` -- - - - _ - - - - 4 k _ - - _ - - h - - � �i t __ _ o- i i f -� i _ _ - _ _ [ _ _ _ _ _ [ - _ - FF _ . - _ - - - - I - - ! _ - - � _ _ - _ - _ I i _ _ _ _ 1 _ � - f F it j. 4 _ __ � - _ _ _ _ _ F , A oA dvD I PON Y o G=N1�CT INTO — i F � _ �a �to G EXIST1�tCs 4"_ PVC' SOILS TO APPROVED CONNECT - EXIST C t BR C145IN Wo AND ) D� U1 , l f y tam I -,Rijm GAL N NEW TANK r f K tj to xlaws,s LAN x �a ,G ,_- i tj si r ell r ►, 5 0 0' G l9 G L-0 5 E j—' r /C 7-A /� �_- 000 GALLOT D0S/NG K cx15TlNG TliNr5- A- 1,as r`AL- Spar 35 E ! GCE ,„ `ou�3 ELE 67H5 PCK' ENG ell 0 5 F/ E /V1 M U Fo l' ; / Plp lh'G 5Z cu _ E m TR p F ; At i L 5 ^ \�Q _ ts_ E Si NGCE h�A r, hr 7--,c} _ , , -- - - _ - -�-#- - ,. i ►� I BR CABINS - ( t - 8) - - - - - - - J • tt A i s 72 - -to �x M r1 x l �= G c a _ T 1 N E W S Vs T f AA e l9� EXISTING- �� syS f _ •4/J9 -SOILS TO APPROVED SJTE kAr -P - i -lAW WCOS;-= Q-Me IN 90N5� � I® Al�- �A. NEW TANfG i i EXISTING SYSTEM - BED SYSTEM 00 cd " i 7 ROWS OF 5 UNITS FOR 35 TOTAL I d ` ! \ . loe WITH FLOW DISTRIBUTION TO EACH ROW 13 co 1� �, r . ` EW- LINE AN TANK (. FOR . CAB INS AND 7 rp� 1 I 1,250 GALLON ANK / p 13! f fi 1,500 GALLON SEPTIC TANK, 1 - 1,000 GALLON \5�� L� 1 DOSING TANK, ELEVATIONS FIELD SET BY ENG. G REFER TO DESIGN MEMO FOR MORE INFO ` DISTRIBUTION BARN SYSTEM - 3 ENCHES [ 0 1 - 80-FOOT, I - -00T, AND 1 - 100 FOOT 1,250 GALLON TANK _ FOR 270 FEET INFILTRATRORS 4vPyC . $FLITTER B - OX - 2 OUTLETS. • 3 ItfILTRATOR TR CHES - 45- UNITS TOTAL 1,500 ALLON EXISTINGTANK IA p- B 97.20, GROUND WATER 93.00, MOUND FILL- -OVER TOP FOR MIN 18" COVER, MANTAIN 4' TO ND WATER a -ri "'Illifflu r nLM n� n III �- -n � i_ i � S R IAL D ISTR IBUT ION FPOM BED � SERIAL DISTRIBUTION rr�p = - MEN NEW TRENCHES ANC. BETWEEN 8 W TRENCHES - 4" PY- w �- 00= SEPTIC FIELD ADD IT IONS I -ON �� _ _ _ 4 - TRENCHES Ol< WEST S IDE � - 22 UNITS . O NEW ADDITIONS T SEPTIC F _� �= �= = ;, = = h = 1 TRENCH OF 6 INFILTRATORS E ADD ONS O SE FIELD .. .. _ - _ _ _ = h= 1 TRENCH OF 7 INF`LTRATORS 3 - TRENCHES ON EAST SIDE - 14 UNITS �= cc = = = ±� = _ = �. _ �— - � J � _ Z _ I TRENCH OF 6 INF ILTRATORS i TRENCH OF 4 INFILTRATORS Z3= _ _ v I TRENCH OF 3 INFILTRATORS 2 TRENCHES OF 5 INF 1LTRATORS - _ r O - BARN SYSTEM -BARN AND CABINS 9 10 -10J97 - _ _ _ 6 r� EXISTING SYSTEM 8/97 _ - - c� `. Q q V FNAL SYSTEM S CABINS AND MAIN HOUSE - 10/99 C = w - - r6 `�' �� - - BAN $`[STEM -BARN AND CABINS 9 10 -10/97 -= 0 = = _ W = m _ = M M J`� �"�. EXITING SYSTEM 8/97 -XFIN.LL SYSTEM 8 CABINS AND MAIN HOUSE o00 . — - S/a SEE DESIGN NOTES FOR DETAIL IS NOT TO SCALE- ADDITIONAL.INFORMATION r IE OF TRENCHES, TANKS, AND PPING TO MATCH EXISTING FIELD PERCOLATION HOLES C � __ � BARN SYSTEM 10/97 � _ �.. _ � _ _ _ _ - _ _ / - �- ASBU ILT 10/97 AND I/Sa PROFILE HOLE h,= = - - - _ r - _ ;FINAL SYSTEM 5/2000 INS'EC1SION iS-ORT - - aOtt artTn I pa Ir*nIIl;I ifin i111 I f'°�tl V� 2 a - SEE DE66N NOTES. FOR _ SERIAL DISTRIBUTION FROM B ADDITIONAL INFORMATION TO NEW TRENCHES AND BETWEEN NEW TRENCHES - 4" PVC - the FRY ING FAN SERIAL DISTRIBUTION FROM BED 4" P,�C FROM BED TO TRENCH TO NEW TRENCHES AND BETWEEN F T I-'5Y&TEM LT O 2 I��' �1i, G fR A I �t C iT SU S EDI x -15 I O I �t o n the F� I I I �l G P A i �l NEW TRENCHES - 4" PVC I AA(I P�