Loading...
HomeMy WebLinkAbout687 Hunters View Ln - 210925214019Environmental Health Department P.O. Box 179 500 Broadway Eagle, CO 81631-0179 Phone: (970) 328-8730 Fax: (970) 328-7185 Permit Permit No. OWTS-023185-2021 Permit Type: OWTS Permit Work Classification: New Permit Status: Under Review Issue Date: Not Issued Expires: N/A On-Site Wastewater Treatement System Project Address Parcel Number 687 Hunters View LN, Eagle, 81631 210925214019 Owner Information Address Hunters View JVCO Land, LLC PO Box 1609 Silverthorne, CO 80498 Phone: (970) 406-1785 Cell: (970) 443-9427 Email: adam@hvbldrs.com Inspections: For Inspections Call: (970) 328-8755 Engineer Phone Email JVA, Inc, Kevin Tone (970) 225-9099 ktone@jvajva.com Contractor License Number Phone Email Beaumont Excavating bexinc@mail.com(970) 390-9393OWTSPL-000111-20 20 Permitted Construction / Details: Install the new system exactly as depicted in the JVA Inc design dated, stamped and signed December 16, 2021 by Kevin A Tone, PE. This system was designed to accommodate the maximum daily flows for 3 single-family homes, lots 143, 144 and 145 in Hunters View in the Frost Creek PUD with a maximum total of 12 bedrooms. The OWTS consists of 3 sewer lines, one exiting each residence. The primary treatment for the system consists of two Valley Precast 2,000 gallon, single compartment tanks in series with an effluent filter and alarm placed at the outlet tee of the second tank. The primary treatment tanks are followed by a 2,000 gallon Valley Precast three-compartment recirculating/dose tank which will send wastewater to an Advantex AX-100 pod for nitrification using an Orenco PF500712 pump. Nitrified effluent flows to the splitter valve for recirculation to the first 2,000 gallon tank for denitrification then is dosed using an Orenco PF501512 pump to an automatic distribution valve (ADV), set level at the high point of the system and made accessible at grade. The ADV will alternate dosed effluent to 1,824 square feet of soil treatment area between two beds, each consisting of 4 rows of 19 Infiltrator Quick 4 Plus Standard chambers for a total of 152 chambers. Maintain all elevations and setbacks including the 2' vertical setback to high groundwater, maintaining the bed no deeper that 0.5' below existing grade. NOTE: The contractor must verify that all electrical components and inspections are covered under the electrical permit associated with the Orenco Vericom control panel and pump connections. The alarm must be connected to a separate circuit. Additional pump details are on the design drawing. Advantex systems must conform to the CDPHE technology approval letter dated May 1, 2018. Contact Eagle County Environmental Health and the design engineer well in advance of requesting inspections prior to backfilling any component of the OWTS. The design engineer is responsible for conducting all inspections necessary to certify the installation and assure functionality of the system. Because reductions are taken in the size of the STA, proof of an active operations and maintenance contract must be provided with final certification. System certification, along with photos and a record drawing is required to be submitted to, and approved by, Eagle County Environmental Health prior to the use of the system or occupancy of the dwellings. Wednesday, December 29, 2021 1 THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT Issued by: Environmental Health Department, Eagle County, CO Claire Lewandowski Date CONDITIONS 1. 2.ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED 3.THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT4.1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON-SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN ON-SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED Wednesday, December 29, 2021 2 Inspection Result Eagle County, Colorado P.O. Box 179 500 Broadway Eagle, CO Phone: (970) 328-8730 Fax: (970) 328-7185 IVR Phone: 1-866-701-3307 Inspection Number: EAGLE AREA - 731 HUNTERS VIEW - 525160 Permit Number: OWTS-023185-2021 Inspection Date: 08/24/2023 Inspector: Weems, Kirk Permit Type: OWTS Permit Inspection Type: OWTS Final Inspection Work Classification: NewOwner:Hunters View JVCO Land, LLC Job Address:687 Hunters View LN IVR Pin Number:194994 Eagle, 81631 Project:<NONE> Parcel Number:210925214019 Contractor:Phone: (970) 390-9393 / Cell: Beaumont Excavating Inspection Status: Approved Inspection Notes Inspector Comments Added Item: Septic Tank Two Valley Precast 2,000 gallon, single compartment tanks in series with an effluent filter and alarm placed at the outlet tee of the second tank were installed. The primary treatment tanks are followed by a 2,000 gallon Valley Precast three-compartment recirculating/dose tank which will send wastewater to an Advantex AX-100 pod for nitrification using an Orenco PF500712 pump. Nitrified effluent flows to the splitter valve for recirculation to the first 2,000 gallon tank for denitrification then is dosed using an Orenco PF501512 pump to an automatic distribution valve (ADV). The pump was set to dose 150 gallons per dose to the STA. 8/24/23 - Kirk Present at startup with Valley Precast and JVA. Confirm tanks and Advatex system installed and operational. Tank location does have high groundwater. Inspection ports are present in area of tank to ensure ground water is not present when tank is pumped to prevent tanks floating. Added Item: Record Drawing Received 9/5/2023 from JVA Inc. Added Item: Record Photos Received 9/5/2023 from JVA Inc. Added Item: Site and Soil Received 12/28/2021 from JVA Inc. Added Item: Higher Level Treatment System O&M received 9/5/2023 - Exp 8/30/2026. 8/24/23 - Kirk Present at startup with Valley Precast and JVA. Advantex system installed and operational. Tuesday, September 5, 2023 For more information visit: http://www.eaglecounty.us Page 1 of 2 Added Item: Final Certification Letter Received 9/5/2023 from JVA Inc. Added Item: General Plan Received 12/28/2021 from JVA Inc. Added Item: Soil Treatment Area (STA) 1,824 square feet of soil treatment area between two beds, each consisting of 4 rows of 19 Infiltrator Quick 4 Plus Standard chambers for a total of 152 chambers was installed. 8/24/23 - Kirk Present at startup with Valley Precast and JVA. Squirt test perfromed. Added Item: Identification of Systems Contractor Beaumont Excavating was the licensed installer. Tuesday, September 5, 2023 For more information visit: http://www.eaglecounty.us Page 2 of 2 September 2, 2023 Claire Lewandowski, Environmental Health Specialist III Eagle County Environmental Health 500 Broadway Street Eagle, CO 81631 RE: Onsite Wastewater Treatment System Final Certification – 659 Hunters View, Lots 143- 145 Dear Claire: The Onsite Wastewater Treatment System (OWTS) covered under Eagle County Permit No. OWTS-023185-2021 was installed by Beaumont Excavating for 659 Hunters View and is ready for final certification from Eagle County Environmental Health. This letter certifies that the construction of the OWTS was completed as per the approved design plan. The final record drawings from JVA, three-year maintenance contract, and construction photographs are provided as attachments. As part of the final approval process JVA observed that start-up was completed by the manufacturer’s representative and completed a site visit to check all system components. The system is connected and can be monitored remotely as required in the PUD. Sincerely, JVA, INCORPORATED By: ________________________ Simon Farrell, P.E. Project Manager, Associate Enclosure: Attachment A – Record Drawings Attachment B – Maintenance Contract Attachment C – Construction Photographs CC: Chelsea Fagan, JVA ATTACHMENT A – RECORD DRAWINGS WSWSWSWSWSWSCONFORMED TO CONSTRUCTION RECORD © JVA, Inc.JVA, Inc.817 Colorado Ave., Suite 301 www.jvajva.com 970.404.3100 Glenwood Springs, CO Zip 81601 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver © JVA, Inc.JVA, Inc.817 Colorado Ave., Suite 301 www.jvajva.com 970.404.3100 Glenwood Springs, CO Zip 81601 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver CONFORMED TO CONSTRUCTION RECORD OPEN CLOSE OPEN CLOSECLOSE OPENOPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSEOPEN CLOSE © JVA, Inc.JVA, Inc.817 Colorado Ave., Suite 301 www.jvajva.com 970.404.3100 Glenwood Springs, CO Zip 81601 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver CONFORMED TO CONSTRUCTION RECORD © JVA, Inc.JVA, Inc.817 Colorado Ave., Suite 301 www.jvajva.com 970.404.3100 Glenwood Springs, CO Zip 81601 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver CONFORMED TO CONSTRUCTION RECORD ATTACHMENT B – MAINTENANCE CONTRACT ATTACHMENT C – CONSTRUCTION PHOTOGRAPHS Hunters View OWTS 16 Construction Photographs *************************************************************************** APPLICATION FOR ON-SITE WASTEWATER TREATMENT SYSTEM (OWTS) PERMIT INCOMPLETE APPLICATIONS MAY NOT BE ACCEPTED (SITE PLAN MUST BE INCLUDED) FEE SCHEDULE APPLICATION FEE FOR NEW OWTS OR MAJOR REPAIRS $800.00 MINOR REPAIR FEE $400.00 Fee includes the design review, permitting and maintenance of OWTS records Make all checks payable to: Eagle County Treasurer Property Owner: _______________________________________Phone: ________________________ Owner Mailing Address: ________________________________ email: _________________________ Professional Engineer: __________________________________ Phone: ________________________ Applicant / Contact Person: ______________________________Phone: ________________________ Licensed Systems Contractor Name / Company: ___________________________________________ Contractor Mailing Address: _________________________________ Contractor License #:_______ Contractor Phone Number: ________________________ email: ______________________________ OWTS Permit Application is for: ____ New Installation ____ Alteration ____ Repair Tax Parcel Number: _________________________________ Lot Size: ________________________ Assessor’s Link: www.eaglecounty.us/patie/ Physical Address: _____________________________________________________________________ Legal Description: ____________________________________________________________________ Building Type: _____ Residential / Single Family _____ Residential / Multi Family _____ Commercial / Industrial Number of Bedrooms: ______ Number of Bedrooms: ______ Type of Use: _______________ *As of 06/27/2014, all systems require design by a Registered Professional Engineer. Type of Water Supply: ____ Private Well ____ Spring ____ Surface ____ Public If Public, Name of Supplier: ____________________________________________________________ Applicant Signature: ______________________________________Date:_______________________ **************************************************************************** Office Use Only: OWTS PERMIT # __________________ BUILDING PERMIT # ____________________ Amount Paid: ___________ Receipt #: ___________ Check #: ___________ Date: ______________ DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX: (970) 328-8788 TOLL FREE: 800-225-6136 www.eaglecounty.us P.O. Box 179 500 Broadway Eagle, CO 81631 environment@eaglecounty.us December 16, 2021 Ms. Claire Lewandowski, REHS Eagle County Environmental Health 590 Broadway Eagle, CO 81631 RE: Frost Creek - Onsite Wastewater Treatment System Design – Hunters View Lots 143, 144, & 145, Eagle County, CO Dear Claire: JVA Inc. (JVA) has prepared a design of an onsite wastewater treatment system (OWTS) to serve Hunters View Lots 143, 144, & 145 within the Frost Creek PUD. JVA is the designated engineer to process all OWTS permit applications within Frost Creek. JVA has prepared the OWTS design to be in general conformance with OWTS requirements of the PUD. The 2020 annual Water Quality Monitoring Report prepared by Wright Water Engineers documents exceedances of the 85th percentile background concentrations during sampling events in 2020. The report states the following ‘While the concentrations observed in 2020 were high for Total Phosphorus and Total Suspended Solids in surface water, upon evaluation of the pattern of concentrations of each water quality parameter for surface and groundwater at the Frost Creek PUD, there are no evident increasing trends in the concentration of the sampled parameters that were outside of the range of historical values. Therefore, all three components of the trigger limits have not yet been met, and mitigation action is not yet required.’ Sincerely, JVA, INCORPORATED By: _______________________ Simon Farrell, P.E. Project Manager, Associate Attachment A - OWTS design – Hunters View Lots 143, 144, & 145 Attachment B - Visual and Tactile Soil Evaluation Attachment C - Discharge pump calculations WSOWTS GENERAL NOTES & SITE PLANC3.0 REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY: DRAWN BY: CHECKED BY: JOB #: DATE: © JVA, INC.HUNTERS VIEW LANEFROST CREEK, EAGLE COUNTY, COSHEET NO. 2476.15.2c 9/02/2021 JLS QDH/RMM QDH/RMM JVA, Inc.JVA, Inc.817 Colorado Ave., Suite 301 www.jvajva.com 970.404.3100 Glenwood Springs, CO Zip 81601 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver LOTS 143 144 1451058.9e DECEMBER 2021 JNG JNG KAT FORCEMAIN PLAN & PROFILEC3.1 REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY: DRAWN BY: CHECKED BY: JOB #: DATE: © JVA, INC.HUNTERS VIEW LANEFROST CREEK, EAGLE COUNTY, COSHEET NO. 2476.15.2c 9/02/2021 JLS QDH/RMM QDH/RMM JVA, Inc.JVA, Inc.817 Colorado Ave., Suite 301 www.jvajva.com 970.404.3100 Glenwood Springs, CO Zip 81601 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver LOTS 143 144 1451058.9e DECEMBER 2021 JNG JNG KAT OPEN CLOSE OPEN CLOSE CLOSE OPEN OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE OPEN CLOSE TREATMENT SYSTEM DETAILSCD3.0LOTS 143 144 145REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY: DRAWN BY: CHECKED BY: JOB #: DATE: © JVA, INC.HUNTERS VIEW LANEFROST CREEK, EAGLE COUNTY, COSHEET NO. 2476.15.2c 9/02/2021 JLS QDH/RMM QDH/RMM JVA, Inc.JVA, Inc.817 Colorado Ave., Suite 301 www.jvajva.com 970.404.3100 Glenwood Springs, CO Zip 81601 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver 1058.9e DECEMBER 2021 JNG JNG KAT SOIL TREATMENT AREA DETAILSCD3.1LOTS 143 144 145REVISION DESCRIPTIOND'WNDES'DDATENO.DESIGNED BY: DRAWN BY: CHECKED BY: JOB #: DATE: © JVA, INC.HUNTERS VIEW LANEFROST CREEK, EAGLE COUNTY, COSHEET NO. 2476.15.2c 9/02/2021 JLS QDH/RMM QDH/RMM JVA, Inc.JVA, Inc.817 Colorado Ave., Suite 301 www.jvajva.com 970.404.3100 Glenwood Springs, CO Zip 81601 Boulder ● Fort Collins ● Winter Park Glenwood Springs ● Denver 1058.9e DECEMBER 2021 JNG JNG KAT October 5, 2020 Ms. Claire Lewandowski, REHS Eagle County Environmental Health 590 Broadway Eagle, CO 81631 RE: Hunter’s View Phase II OWTS 16 – Site and Soil Investigation Report for an Onsite Wastewater Treatment System (OWTS) JVA Job No. 1058.1e Dear Claire: Enclosed in this report are the results of the site and soil evaluation for OWTS 16 (Lots 143,144,145) proposed OWTS located in Frost Creek, Colorado. This report provides information needed to support the design of an OWTS including: results from the preliminary investigation, the site visit, and the soil evaluation. Design calculations are included in the drawing Permit Set attached. PRELIMINARY INVESTIGATION In preparation for the site visit and soil evaluation, a preliminary investigation was conducted the week of August 17th, 2020. Architectural site plans, aerial imagery, and previous Geotechnical investigations were used for the preliminary investigation. Geotechnical investigations were performed by HP Geotech in October 2002 across Frost Creek for OWTS suitability. Results from the HP Geotech report showed that for the proposed location, Test Hole A and B had a topsoil from zero to six inches deep, a clay layer to three feet deep, and a sandy gravel from three to eight feet deep. No groundwater was encountered in either hole. SITE VISIT AND SOIL EVALUATION A site visit and soil evaluation were conducted the week of August 24th, 2020. The purpose of the site visit and soil evaluation was to confirm hypotheses from the preliminary investigation, identify the topography, landscape position, vegetation, and site constraints for the proposed OWTS, and to conduct a visual and tactile soil evaluation of the underlying soils where the proposed soil treatment area (STA) is to be located for both suitability and sizing. The topography of the site slopes from east to west. The dominant vegetation at the proposed OWTS consists of native grasses. Site Constraints are shown in the Permit Documents. For the visual and tactile soil evaluation, two soil profile holes were excavated using a tracked excavator in the locations identified in the Permit Documents. As seen in Table 1 below, soil morphology for Soil Profile Hole One from zero to 2.5 feet was Soil Type 2A, with high groundwater at 2.5 feet. Soil morphology for Soil Profile Hole Two from zero to 2.5 feet was Soil Type 2A, with high groundwater at 2.5 feet. Figures 1 through 4 below show the soil profile holes and corresponding morphology. Therefore, Soil Type 2A was identified as the soil type, with high groundwater at 2.5 feet. Frost Creek Hunter’s View Phase II OWTS 16 Site and Soil Investigation 10/5/20 2 of 2 Table 1 – Visual and Tactile Soil Results Profile Hole Depth (ft.) Percent Rock Soil Texture Soil Structure Type Soil Structure Grade Soil Type 1 0 – 2.5 0% retained on 20 mm sieve 0% retained on 2 mm sieve Silt Loam Blocky Weak 2A 2.5 Groundwater 2 0 – 2.5 0% retained on 20 mm sieve 0% retained on 2 mm sieve Silt Loam Blocky Weak 2A 2.5 Groundwater Figure 1 – Profile Hole One Figure 2 – Profile Hole One Soil Morphology Figure 3 – Profile Hole Two Figure 4 – Profile Hole Two Soil Morphology Sincerely, JVA, INCORPORATED By: _______________________ James Cochran, P.E. Project Engineer Job Name: Hunters View OWTS 16 Job Number: 1058.9e Date: 12/16/2021 By: JNG Line Variable Description Value Unit Note Lateral Distribution Piping Nlaterals Number of Laterals being feed by one pump cycle = 4.0 -- 8 total laterals. ADV feeds 4 at once Llateral Lateral Length = 79 ft Orifice Spacing = 3.0 ft Manual Input Norifices Number of Orifices per Lateral = 26 -- Orifice Discharge and Total Flow Corifice Orifice Discharge Coefficient = 0.63 -- Sharp Edge Dorifice Diameter of Orifice = 0.13 in 1/8'' diameter orifice g Acceleration due to Gravity = 32.2 ft/s2 hn Residual Head at last Orifice =5.00 ft Chosen value. Squirt test height Qn Discharge from Single Orifice = 0.43 gpm = 2.45Corfice·(Dorfice)2·(2ghn)0.5 Qlateral Flow into Each Lateral = 11.40 gpm = Qn x Norifice Qtotal Total Flow into Soil Treatment Area = 45.6 gpm = Qlateral x Nlaterals Headloss in Lateral Distribution Piping (Hazen-Williams) Clateral Hazen-Williams Coefficient = 150 -- For PVC dLateral Lateral Inside Diameter = 1.59 in For 1.5'' SCH 40 hlateral Headloss due to Friction in Lateral = 0.73 ft = 10.5Llateral·(Qlateral/Clateral)1.85·(dlateral)-4.87 hf-lateral Actual Headloss due to Friction in Lateral = 0.243 ft = 1/3 x hlateral (Accounting for Orifices) Headloss in Manifold (Hazen-Williams) Lmanifold Length of Manifold = 9 ft Same as the STA Max Width dmanifold Manifold Inside Diameter = 1.59 in For 1.5'' SCH 40 Cmanifold Hazen-Williams Coefficient = 150 -- For PVC hmanifold Headloss due to Friction in Manifold = 1.08 ft = 10.5Lmanifold·(Qtotal/Cmanifold)1.85·(dmanifold)-4.87 hf-manifold Actual Headloss due to Friction in Manifold = 0.36 ft = 1/3 x hmanifold (Accounting for Orifices) Headloss in Delivery Piping (Hazen-Williams) Lpipe Length of Delivery Pipe = 780 ft From Dosing chamber to ADV, and ADV to manifold dpipe Delivery Pipe Inside Diameter = 1.84 in For 2'' HDPE DR 9 Cpipe Hazen-Williams Coefficient = 150 -- For HDPE Pipe hf-pipe Headloss due to Friction in Pipe = 46.42 ft = 10.5Lpipe·(Qtotal/Cpipe)1.85·(dpipe)-4.87 Total Dynamic Head (Hazen-Williams) hf-fittings Headloss due to Fittings = 2.88 ft Headloss through Automatic Distributing Valve = 13.00 ft hs Static Head = 15.00 ft Max Elevation difference (typically in tank to ADV) TDH Total Dynamic Head = 82.90 ft = hs + hf-fittings + hf-pipe + hf-manifold + hf-lateral + hn Volume of pipes Delivery Pipe (drain back to tank) = 108 gal = ((3.14/4)*(dpipe/12)2*(Lpipe))*7.48 STA Laterals = 33 gal = ((3.14/4)*(dpipe/12)2*(Lpipe))*7.49 Total Volume = 140 gal Duty Point Flowrate =46 gpm Total Dynamic Head =83 ft HUNTERS VIEW OWTS 16 (Lots 143 144 145) PUMP CALCULATIONS OWTS 16 Pump Calculation - JNG - Pump Design Calculations Page 1 of 2 Job Name: Hunters View OWTS 16 Job Number: 1058.9e Date: 12/16/2021 By: JNG OWTS 16 Pump Calculation - JNG - Pump Design Calculations Page 2 of 2