HomeMy WebLinkAbout2890 Taylor Creek Rd - 238731200002Permit No. OWTS-9-15-13483
Environmental Health
Department
P.O. Box 179
500 Broadway
Eagle, CO 81631-0179
EAGLE COUNTY Phone: (970) 328-8730
Fax: (970) 328-7185
Project Address
2890 TAYLOR CREEK RD, BASALTAREA,
Owner Information
Taylor Creek Holding, LLC
On -Site Wastewater
Treatement System
isIinI
Issue Date: 11/9/2015
Parcel Number
238731200002
Permit Type: OWTS Permit
Work Classification: New
Permit Status: Final
Address
400 E Main ST Phone:
Aspen, CO 81611 Cell: (970) 309-2015
Email: plantdoc@hotmail.com
Expires: 3/8/2016
Engineer Phone Email Inspections:
High Country, Matthew Langhorst (970) 945-8676 For Inspections Call: (970)
Contractor License Number Phone Email 328-8755
Rocky Mountain Builders (303) 968-7183
Permitted Construction / Details:
NOTE: THIS OWTS WAS INSTALLED BY AN UNLICENSED CONTRACTOR WITHOUT A PERMIT. THE DESIGN
ENGINEER PROVIDED SYSTEM CERTIFICATION ON JUNE 24, 2016 INDICATING WHAT WAS INSTALLED MET THE
PLANS AND IS ADEQUATE TO SERVE THE USE. INFILTRATOR CHAMBERS WERE USED INSTEAD OF THE ARC 36
CHAMBERS SPECIFIED ON THE DESIGN.
Install the OWTS exactly as depicted on the High Country Engineering, Inc. Design drawing dated September 24,
2015 as revised stamped, signed and dated November 9, 2015. System is designed to serve a three bedroom
caretaker unit.
System consists of a 1,000 gallon, two compartment, Valley Precast septic tank with effluent filter placed in the
outlet tee and a 500 gallon Valley Precast dose chamber equipped with an Orenco PF 3005 effluent pump. The soil
treatment area consists of 750 square feet of soil treatment area (prior to the 30% reduction for using chambers) via
the installation of 36 ADS, ARC 36, pressure -dosed chambers arranged in three shallow trenches atop 3 feet of C-33
sand with 12 chambers in each trench.
Contact the design engineer for details on installing the three way pressure distribution manifold to assure proper
drain back to the pump after sending a dose to the soil treatment area. All weep holes drilled in the distribution
pipes facing down must have scour protection underneath them to prevent sand scouring. Do not install in wet or
frozen ground.
Contact the design engineer to perform the necessary squirt test and all inspections necessary to certify the system
and to prepare the as -built drawings. System certification along with as -built drawings and photos must be
submitted to, and approved by, Eagle County Environmental Health prior to the use of the system or occupancy of
the residence.
Thursday, August 17, 2023
CONDITIONS
1. THIS PERIMT EXPIRES BY TIME LIMITATION AND BECOMES NULL AND VOID IF THE WORK AUTHORIZED BY THE PERMIT IS NOT COMMENCED WITHIN 120 DAYS
OF ISSUANCE, OR BEFORE THE EXPIRATION OF AN ASSOCIATED BUILDING PERMIT
2. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY PUBLIC HEALTH AGENCY ON -SITE WASTEWATER TREATMENT SYSTEM
REGULATIONS ADOPTED PURSUANT TO AUTHORITY GRANTED IN CR.S. 25-10-101, et seq., AS AMENDED
3. THIS PERMIT IS VALID ONLY FOR PERFORMING WORK ON OWTS ASSOCIATED WITH STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS CONNECTION TO, OR USE WITH, ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT
4. 1.6(A)(1) EAGLE COUNTY PUBLIC HEALTH AGENCY ON -SITE WASTEWATER TREATMENT SYSTEM REGULATIONS REQUIRES ANY PERSON WHO CONSTRUCTS,
ALTERS OR INSTALLS AN ON -SITE WASTEWATER TREATMENT SYSTEM TO BE LICENSED
Ray Merry November 09, 2015
Issued by: Environmental Health Department, Eagle County, CO Date
Thursday, August 17, 2023