Loading...
HomeMy WebLinkAbout297 A Green Meadow Dr - 239122304001 - 1679-97ISINDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway - Eagle, Colorado 81631 Telephone: 328-8755 Repair Perm it YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE PERMIT NO. 1679 Please call for final inspection before covering any portion of installed system. Original Permit #1100 NNER: Clay Wells PHONE:(970) 963-4996 41LINGADDRESS: 0297 Green Meadow Drive City: Carbnndal a Stag: CO Zip: 81623 IPLICANT: Glenn Meehan, Dreager Excavati g PHONE: (970) 927-1411 !STEMLOCATION: 0297 Green Meadow Drive TAX PARCEL NUMBER: i91-223-04-001 -ENSEDINSTALLER: Dreager Excavating, Glenn Meehan UCENSENO: 12-97 :SIGN ENGINEER OF SYSTEM: E.O. Cbnr6b Tn ConGijlting FnginPPrc STALLATION HEREBY GRANTED FOR THE FOLLOWING: 1250_GALLON SEPTIC TANK existing tank in place , with distribution box with levelors (SORPTION AREA REQUIREMENTS: SQUARE FEET OF SEEPAGE BED 1688 SQUARE FEET OF TRENCHBOTrom. via 55 chambers, as per design. �ECIAL EQUIREMENTS: Install a _ n0 - menc{� the use o grave i Try to avoi this or pipe around the -boulders -in the area. Existing bed is not adequate size and should not be used until the area is increased- Engineer is responsible for final in ec IVRRONMENTAL HEALTH APPROVAL � YL CONDITIONS: DATE: May 16, 1997 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS. ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25- 10. 104. 1973. AS AMENDED. . 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VKOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3 CHAPTER IV, SECTION 4.0329 REQUIRES ANY PERSON WHO CONSTRUCTS. ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. IAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED IOR TO COVERING ANY.PORTION OF THE SYSTEM. tTALLEDABSORPTION ORDISPERSAL AREA: 2170 SQUAREFEET.Vla 70 infiltrator units as per design existing KALtED SEPTIC TANK: 12 5 0 GALLON DEGREES FEET FROM PTIC TANK ACCESS TO WITHIN 8- OF FINAL GRADE AND PROPER MATERIAL AND ASSEMBLY X YES —NO COMPLIANCE WITH COUNTY / STATE REQUIREMENTS: X YES —NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL A000nVAL OF SYSTEM IS MADE ARRANGE A REANSPECTION W"EN WORK IS CORRECMn/ MMENTS:,. Engineer certification received 10-13-97. VIRONMENTAL HEALTH VIRONMENTAL HEALTH APPROVAL: (RE -INSPECTION IF NECESSARY) DATE: n toc bPr i4, 1 A.17 DATE' RETAIN WITH RECEIPT RECORDS ANT / AGENT: OWNER: A (Site Plan MUST be attached) ISDS Permit /00 APPLICATION FOR INDIVIDUAL SEW GE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE-- EAGLE COUNTY P. O. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (El Jebel) ************************************************************************** * PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 * * * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" ************************************************************************** PROPERTY OWNER: ( �C �1 PHONE: MAILING ADDRESS: C> 76reen klnenjour dr- Cecrbohda P I&13 APPLICANT/ CONTACT PERSON: 69(ev)r, J. M ee�ah PHONE: (1-I o z,`7- 3 `f3t MAILING ADDRESS: 0061 Z b4t2,jk,5 (on•e & Erota, LICENSED ISDS CONTRACTOR: 6I'em),, J. meeiykn PRIONE: COMPANY/DBA: reaa-2f 4' XCawt►v,a ADDRESS: (W72- l,�yK 5 lama A l ai (3a5o, if, Cca�o r� z PERMIT APPLICATION IS FOR: ( ) New Installation ( ) Alteration Repair LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Building Permit # (if known) a5pe" sin, U,.e w Legal Description: Subdivision: Filing: _Block: Lot No./ Tax Parcel Number: O` l_ L - -�- O Lot Size: Street Address: 0 297 Green J eacfo:u draft BUILDING TYPE: (Check applicable category) (.Residential/Single Family ( ) Residential/Multi-Family* ( ) Commercial/Industrial* Number Number Type _ TYPE OF WATER SUPPLY: (Check applicable category) ( ) Well ( ) Spring ( ) Surface ( -) Public Name of Supplier: (Uw'. *These systems ire design by SIGNATURE: ********************* of Bedrooms of Bedrooms Registered Professional Engineer Date: /y✓ *************************************************** TO BE COMPLETED BY THE COUNTY AMOUNT PAID: RECEIPT #: CHECK #: It G DATE: _ CASHIER: „s Tara tpP !Y� C/ ✓Pi�i/ ISDS PERMIT rr /1&0 PERCOLATION TEST EAGLE COUNTY ENVIRONMENTAL HEALTH DEPT. OWNER: -Z�h M0 LEGAL DESCRIPTION:As42rmi Move, la,'i, �Iiw L , f 14 ga5-0115 (wk� MAILING ADDRESS: TYPE OF DWELLING: Sjn I Fa-ilResiolJ NUMBER OF BEDROOMS 3 TEST HOLES PRE-SOAKED: YES NO TTME � wnmFu T)RprPT4 TMt-LrVa r%V VAT T rlAM” f1TT TT/1TTT r 1 2 3 1 2 3 1 2 3 ill 2 3 1 1lV.L iJJl 0", /owe 0' 11 15 !� 17 :Z0 .2j :2-2 ' a� �Z ' 22- I 5 5 2.5 1l l7 `f S 4 `f0 i3.3 aD 31 10 3/ 3 �4 3 y z g CFO 6.' CFO g' ,1 35 3c 3% 4 3 3 $ — — yo i �z 3� 3 % 3 Z -1 ��.`7 40 13.3 6' s �6 47 e 3 I' S 3 $ 3 $ ' g 410 13.3 46 71 50 sr 5Z �- 4 z 3 g 4 I _7 a o io s 3 ' 15-Lo ro- 3 5 ,7D Time to drop last inch PERC RATE: j/>e �,] API MINIMUM SEPTIC TANK SIZE: MINIMUM LEACH FIELD SIZE: �7 � P �is.',-/ P 15 V of /0 S$Z � 0u Ih � ��toY ctiaw � COMMENTS: *P/Qce 1d5,oE'eXw C � 6�+ �i��� 41Q,.4i111 • PERC TEST DONE BY: nviro rev. 6/90ks Officer DATE: 9-10- q/ 0 irl� u � icy Ira Community Development Department (970) 328-8730 Fax: 11970) 328-7185 TDD: (970) 328-8797 EAGLE COUNTY, COLORADO Date: May 16, 1997 TO: Dreager Excavating FROM: Environmental Health Division Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 RE: Reissuance of Individual Sewage Disposal System Permit No. 1679-97. Tax Parcel # 2391-223-04-001. Property Location: 0297 Green Meadow Drive, Carbondale, CO., Wells residence. Enclosed is your ISDS Permit No. 1679-97. It is valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County does not perform final inspections on engineer designed systems. Your TCO will not be issued until our office receives this certification. Permit specifications are minimum requirements only, and should be brought to the property owner`s attention. This permit does not indicate conformance with other Eagle County requirements. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files E. O. Church, Inc. Consulting Engineers 1/ EOC E.O. CHURCH, INC. ENGINEERS & GEOLOGISTS October 13, 1997 Clay Wells 0297 Green Meadow Drive Carbondale, CO 81623 Subject: Installation Observation, Repair OWS Design Lot 14, Aspen Mountain View, Filing 2 0297 Green Meadow Drive Eagle County, Colorado Job No. 8499 Dear Mr. Wells, We have observed the installation of the new drain trenches during construction of the repair onsite wastewater system (OWS). The in- stallation was in accordance with our design dated May 11, 1997 and the Eagle County ISDS Permit 1679-97. We were called and asked to confirm the field, trenches, size for four bedrooms, as the septic tank would allow four bedrooms: Per our design, which stated if additional bedrooms were desired, an additional 15 chambers should be installed, the system was expanded. The installation was done for a four bedroom residence with 70 cham- bers. The existing septic tank was appropriate for four bedrooms. The chamber trenches were installed as indicated on the attached Figure 1. A diverter valve was installed and a 6 inch PVC pipe was installed to protect the effluent service line where it went beneath the driveway. A six lines outlet distribution box was installed for the eight trenches as indicated on Figure 1. The upper and lowest trenches are short trenches connected by serial distribution to the 2nd and 7th trenches. If there are any questions, call. Q. CAS''°fiS no 13172 0 N A1� E E. O. CHURCH, INC. rd O. Church, 3 copies sent xc: Eagle County Envirn. Health, xc: Robert Nelson, P.O. BOX 6961, or if we can be of further service, please co P.O. BOX 179, Eagle, CO 81631-7185 Snowmass Village, CO 81615 925 East 17th Avenue ° Denver, Colorado 80218-1407 (303) 832-9692 FAX (303) 832-3517 P:O. Box 2869 ° Evergreen, Colorado 80437-2869 (303) 674-0660 FAX (303) 674-0813 • �0 E.O. CHURCH, INC. ENGINEERS & GEOLOGISTS May 11, 1997 Clay Wells 0297 Green Meadow Drive Carbondale, CO 81623 Subject: Subsurface Evaluation & Repair OWS Design Lot 14, Aspen Mountain View, Filing 2 0297 Green Meadow Drive Eagle County, Colorado Job No. 8499 Dear Mr. Wells, As requested, we have observed subsurface conditions in a test pit, reviewed the soils data from the original Onsite Wastewater System (OWS) and prepared a repair Onsite Wastewater System (OWS) design for the subject site. The purpose of our project was to design a repair OWS for the property. SITE CONDITIONS - The investigated site is an approximate 2.7 acre lot as indicated on Fig. 1. The site is located in a rural mountain area where onsito wastewater systems (OWS) are required. Water is prcvided by a public water district. The location of the existing septic tar_k and drain field is indicated on Fig. 1. EXISTING CONSTRUCTION - A 3 bedroom residence exists as indicated on Fig. 1. The se oad for a three bedroom dwelling is 450 gallons j)e_, per day (GPD), 675 GP with peaking factor. A garbage grinder and clothes washer are inc u e in e esign calculations. The existing OWS was installed in 1992 based on a design by ENARTECH, Inc. using perc tests by Eagle County. We understand a 1250-gallon septic tank and 22 chambers were installed as indicated on Fig. 1. Although not known, we understand the 22 chambers were installed in a bed configuration. We estimate the bed is 4 chambers wide. The repair trenches are proposed in the southwest portion of the lot. The ground surface slopes_gently to moderately to the south. The slope in the drain field area is 16% to the south. The surface vege- tation consists of a sparse cover of native grasses and scrub oak. SUBSURFACE CONDITIONS - Subsurface conditions was exposed in a backhoe test pit in the proposed trench area. Soils consisted of a thin top- soil layer underlain to 2.5 feet of clay topsoil underlain by stiff si s i sandy clay underlain by sandy clay -with boulders to thef the it Or p co a ion es s were performed in lieu of soil classi ica ion and designation of a long term acceptance rate. No ground water was observed in the test pit. RECOMMENDATIONS - The results of our investigation indicates an OWS can be installed at the location presented on Fig. 2. The OWS design is based on an avera wage load of 450 GPD, and a long term accep- tance rate (LTAR) of .4 gal ons/square foot/day (G/SF/D). A existing rV 925 East 17th Avenue • Denver, Colorado 80218-1407 (303) 832-9692 FAX (303) 832-3517 P.O. Box 2869 • Evergreen, Colorado 80437-2869 (303) 674-0660 FAX (303) 674-0813 _.. _.._..-.— - , . . - 1 J f JJCO f 1 OJ i . Ud rate (LTAR) a 0.4 gallons/square foot/day (G/SF/D)_ A existing Cl:250 � gallon 2 compartment septic tank is adequate and will not need `mo.dification..... ased on a 3 bedroom residence and a LTAR 0.4 G/SF/D, and area of 68s F is required, we reco trenches with a 6 foot separation between trenches, which would b 5 chambers at 15.5 SF per chamber and a. 50!s reduction in field area w� installation a trench- es. we recommend the trenches be connected far both parallel and serial distribution as indicated on Fig. 2. The chamber trenches should be connected �re of th of the trenches, as well.as having distributox with "levelors" o allow control of effluent distribu _. en a is oc upie full time, so we do not recommend serial distribution be the only distribution method. Chambers must be installed so the outlet serial pipes are set on un- disturbed ground so effluent will not flow along the trench excava- tion. We recommend the existing bed be connected to the system and used after the field is allowed to dry for a minimum of I year. with the 4'trenches and 1 bed, we believe 1 section of the system can be closed and allowed to rest annually by adjusting the levelors. Because of boulders which occur in the subsoil, some leveling of the trench excavations may be required. Where a boulder occurs in the chamber footprint and is7 removed, we recommend filling the resu?ting hole with 3.4 inch gravel. if additional bedrooms are anticipated, we recommend installing .a larger septic rank and field. The tank size should be increase by 250 gallor: per anticipated bedroom for each bedrooms over 4 bedroom. Ad- diticral bedrooms will `-equ're an additional. 232 SF of chamber trench, or 15 chambers per bedroom. OPERATION AND. MAINTENANCE - The owner must real,ze an 0W4 is different from a public sewer system. The owner must be aware of and assure Responsibility for maintenance of the system. We recommend the septic: tank be pumped at least every 2 years. There are daily considerations such as not putting plastic or other nonbiodegradable materials into the OWS, Water use must be carefully monitored so toilets are not allowed to run when seals malfunction. To. illustrate the point, it should be noted a running toilet will consume in excess of 1,000 GPD if allowed to run. As the system is designed for 450 GPD, a 1000 gallon loading will flood and harm the system. LIMITATIONS - our evaluation, layout, design and recommendations are based on data submitted. if subsurface conditions different from those described in this report are encountered, we should be called to ob- serve the subsurface conditions. If proposed construction is changed, we should be notified to evaluate the effect of the changes on the proposed ows. If there are a�, if we can be of further service, please call."R. Edward O. 3 copies sent etc: 'Eagle County Envirn. Health, P.O. BOX 179, Eagle, CO 81631-7185 xc: Robert Nelson, P.O. BOX 6961, Snowmass Village, Co 81615 TOTAL P.02 0297 GREEN MEADOW DRIVE LOT 14. ASPEN MOUNTAIN VIEW. FLNG 2 EAGLE COUNTY. COLORADO SCALE 1"=60' ;` r_r•_ry 111\ 5 t ' t t s 1 t t f{1{ 5 t EXISTING 3 BEDROOM RESIDENCE r I \ EXISTING 1250 GALLON SEPTIC TANK �- EXISTING 12' X 22' 264 SF FIELD LL til . t � WATER LINE GREEN MOUNTAIN DRIVE SITE PLAN AND LOCATION OF EXISTNG CONDITKW JOB NO. 8499 RG_ I l 0297 GREEN MEADOW DRIVE • LOT 14. ASPEN MOUNTAIN VIEW. FILING 2 EAGLE COUNTY. COLORADO { \ , 1 + 1 + +l { + + EXISTING 3 BEDROOM 'l RESIDENCE 1 1 + l 27' + 12 U 6 L + , 1 SERIAL OVERFL W II 4 1 fl + 10 .1 l 11 \8 • ll Lu 4 ? 1 d + ti IN DIVERTER VALVE GREEN MOUNTAIN DRIVE CAL_E "=40' a THE OWS WAS UPSIZED FROM A THRRE BEDROOM TO A FOUR BEDROOM SYSTEM, A TOTAL OF 70 CHAMBERS WERE INSTALLED IN SIX TRENCHES. THE SEWER LINE WAS DOUBLE CASED BENEATH THE DRIVEWAY AND WHERE THE SEWER LINE CROSSED THE WATER LINE, AS -BUILT PLAN OF OWS JOB NO. 8499 FIG. 0297 GREEN MEADOW _DRIVE • l LOT 14. ASPEN MOUNTAN VIEW. EAGLE COUNTY. COLORADO - 1 , 1 , 1 EXISTING BEDROOM t RESIDENCE , 1l 1 , , r ti 111 / SERIAL OVERFLOW / , f , ,1 l 1 �l w RLING 2 PROPOSED DISTRIBUTION BOX WITH FLOW LEVELORS WHERE EFFLUENT LINES CROSS WATER LINES. EFFLUENT LINES MUST BE DOUBLE PIPED FOR 10 FEET ON EACH SIDE OF WATER LINE. INIMUM SETBACK GREEF MOUNTAIN DRIVE - BETWEEN WATERLINE AND TRENCHES PROPOSED FIELD. 5 TRENCHES EACH it CHAMBERS LONG 11X6.25EACH -67.5SF 5 X 67.5 SF = 337.5 SF TOTAL SITE PLAN AND LOCATION OF REPAIR OWS \SCALE - = 40 \ 1 1 JOB NO. 8499 RG. 2 MINIMUM 18' OF COVER OVER TRENCHES EXISTING GROUND SURFACE MINIMUM OF 6 FEET -f� BETWEEN TRENCHES 5 TRENCHES II CHAMBERS PER TRENCH SERIAL AND PARALLEL DISTRIBUTION SPECIFICATIONS DESIGN CRITERIA: NO. OF BEDROOMS - 3 LOAD 0 - 450 GPD LTAR - 0.4 G/ SF/D A = 0 X 1.5/L71 AR A = 1687 S.F. CHAMBERS IN TRENCH 1687 X 0.5 - 844 S.F. FIELD SPECIFICATIONS 5 TRENCHES LENGTH - II CHAMBERS a 6.25 = .5 FT WIDTH - 3 FEET AREA - 5 X II X 15.5 = 852 S.F. EXISTING TREATMENT UNIT: ONE EXISTING 1250 GALLON TWO COMPARTMENT SEPTIC TANK. DISPOSAL FELD DETAILS JOB NO. 8499 FIG. 3 DREAGER EXCAVATING L.L.C. 0092 HOOK'S LANE #13 BASALT, CO., 81621 (970) 927-3431 '/W ' -7 DREAGER EXCAVATING L.L.C. 0092 HOOK'S LANE #13 BASALT, CO., 81621 (970) 927-3431 March 4, 1997 Janet Kohl Eagle County, Colorado Environmental Health Division Dear Janet, This letter is to confirm in writing that the Wells residence at 0297 Green Meadow Drive has only three legal bedrooms. Therefore expansion of the existing leach field is not necessary. Enclosed is a copy of letter from engineer Peter Belau authorizing repair. Mr. Wells has instructed me to get repairs underway as soon as possible and I am prepared to start immediately. Thank you for your attention to this matter. Please call if you have any questions. Thank Yo , Glenn Meehan ENARTECH Inc. Consulting Engineers and Hydrologists February 27, 1997 Mr. Glen Meehan Dreager Excavating 0092 Hooks Lane #13 Basalt, CO 81621 RE: Eagle County ISDS Permit No. 1100-92 Dear Mr. Meehan: This letter is .to authorize the repair of the existing Individual Sewage Disposal System located at 0297 Green Meadow Drive (Lot #14, Oak Ridge II, Aspen Mountain Subdivision). It is my understanding that one or more of the existing 22 Infiltrator chambers has been damaged. The damaged chambers should be replaced on a one -for -one basis in accordance with the manufacturer's requirements and in accordance with my original design report for this project dated April 17, 1992 (copy enclosed). Please give me a call if you have any questions in this regard. Sincerely, ENARTECH, INC. Peter Belau, P.E. PB/jlw Enclosure cc: Eagle County Environmental Health P342-01A DOCS\PJB\34297 01 302 Eighth Street, Suite 325 P.O. Drawer 160 Glenwood Springs, Colorado 81602 (970) 945-2236 Fax (970) 945-2977 INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH P.O. Box 179 - 550 Broadway • Eagle, Colorado 81631 Telephone: 328-7311 or 949-5257 or 927-3823 YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1100 Please call for final inspection before covering anV Dortion of installed system_ OWNER: Robert H. Magel, Jr. PHONE: 925-2115 MAILING ADDRESS: 600 E. Hopkins Suite 303 Aspen, CO 81611 AGENT: PHONE: SYSTEM LOCATION: 0297 Green Meadow Drive Lot 14 Oakridge II LICENSED INSTALLER: Joseph Zamora LICENSE NO. 39-91 DESIGN ENGINEER OF SYSTEM, PERMIT VALID FOR SPRING 1992 INSTALLATION IS HEREBY GRANTED FOR THE FOLLOWING: 1000 GALLON SEPTIC TANK OR GALLON AERATED TREATMENT UNIT. DISPERSAL AREA REQUIREMENTS: SQUARE FEET OF SEEPAGE BED 675 SQUARE FEET OF TRENCH BOTTOM. SPECIAL REQUIREMENTS: Place inspection portals at the end of each trench ENVIRONMENTAL HEALTH OFFICER: DATE: �Y CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, C.R.S. 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. SECTION Ill, 3.21 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED ACCORDING TO THE REGULATIONS. FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED' PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: SQUARE FEET. } INSTALLED SEPTIC TANK: 1250 GALLONS DEGREES FEET t1G V SEPTIC TANK CLEANOUT TO WITHIN 8" OF FINAL GRADE, OR: PROPER MATERIALS AND ASSEMBLY YES NO COMPLIANCE WITH COUNTYISTATE REGULATION REQUIREMENTS: YES NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. COMMENTS: Installed per engineer design specifications. ENVIRONMENTAL HEALTH OFFICER: DATE: /.-;POA�. ENVIRONMENTAL HEALTH OFFICER: DATE: (RE-INSPE NECESSARY) RETAIN WITH RECEIPT RECORDS PERMIT APPLICANT/AGENT: OWNER: AMOUNT PAID: RECEIPT #: CHECK #: CASHIER: ool ISDS Permit # Building Permit #�L APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE- EAGLE COUNTY P.O. BOX 179 EAGLE, CO 81631 328-8730/927-3823(Basalt) PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $125.00 PROPERTY OWNER: MAILING ADDRESS: (coo E,,,,H� gitjS S co APPLICANT/CONTACT PERSON'.-r/ Zit LICENSED SYSTEMS CONTRACTOR: 0 3 PHONE gas -a ins ADDRESS: L: AK-s0kJYJ4&- PERMIT APPLICATION IS FOR: ( ) NEW INSTALLATION LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL Legal Description: 1-or )q 6hKg4p6e U Parcel Number: &c_a2pt0 gliSk, Bo�ok3Ls' 0�} Physical Address: _­)o,-� PHONE: PHONE: q4 3 , / 3 cj 5— ( ) ALTERATION ( ) REPAIR SYSTEM: Lot size • .Z•S Ar,Res zzyy BUILDING -TYPE: (Check applicable category) (y� Residential / Single Family Number of Bedrooms 3 ( ) Residential./ Multi -Family* Number of Bedrooms ( ) Commercial / Industrial* Type HOT TUB Yes (/�.. No WATER CONSERVATION PLAN: Yes ( ) No ( ) TYPE OF WATER SUPPLY: Well( ) Spring ( ) Surface ( ) LowiwtwutY'y wA4r_&5vpPy Public ( ) Name of Supplier: Give depth of all wells within 200 feet of system: *These systems require design by a Registered Professional Engineer NOTE: SITE PLAN MUST BE ATTACHED TO APPLICATION MAKE ALL REMIT ANCE PAYABLE TO: "EAGLE COUNTY TREASURER" SIGNATURE: DATE: *********** ********** *************************** * ************* AMOUNT PAID. RECEIPT# DATE: 9 CHECK # _ CASHIE : TIME LOG - ' Travel Perc Final COMMUNITY DEVELOPMENT DEPARTMENT (303) 328.8730 EAGLE COUNTY, COLORADO August 20, 1992 Robert H. Magel, Jr. 600 E. Hopkins, Suite 303 Aspen, CO 81611 RE: Final of ISDS Permit No. 1100 500 BROADWAY P.O. BOX 179 EAGLE, COLORADO 81631 FAX (303) 32S-7207 This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your dwelling may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at 328-8755. Sincerely, Brenda Henderson Office Assistant Environmental Health /bh ENCL: Information Brochure Final ISDS Permit cc: Files BP# 5240 ENARTECH Inc. Consulting Engineers and Hydrologists April 17, 1992 Mr. Robert H. Magel, Jr. 600 E. Hopkins, Suite 303 Aspen, CO 81611 RE: New Residence, Sewage Disposal Dear Mr. Magel, isres� AANA10® This letter is to provide the design and design certification for the individual sewage disposal system for your proposed residence located on Lot 14 of Aspen Mountain View Subdivision in Eagle County. Please find enclosed the following information: • Site Plan of Lot 14 showing the location of your proposed residence and leachfield. • Field Percolation Test Results • Soil Absorption System Design Calculations The field percolation tests were performed by Roger Boyd, Eagle County Environmental Health Officer. I have reviewed these test results and have inspected the site, including subsurface soil conditions, and I accept these percolation test results for the design of your sewage disposal system. The recommended sewage disposal system for your residence is a 1000-gallon septic tank (or larger) with a soil absorption system.. Any of the following alternative soil absorption systems may be constructed: 1. A 675 square -foot standard leachfield. 2. A 6 foot wide by 113 foot long standard absorption trench. 3. 225 feet of 10-inch diameter ADS "SB2" Gravelless Pipe. (4. 22 standard (12-inch) "Infiltrator" chambers in a seepage bed. 5. 18 "Infiltrator" chambers in a seepage trench. 6. 25 "Contactor" chambers in a seepage bed or trench. 302 Eighth Street, Suite 325 P.O. Drawer 160 Glenwood Springs, Colorado 81602 (303) 945-2236 Mr. Robert H. Magel, Jr. Page - 2 All of the above are minimum requirements; additional soil absorption may be installed at your option. The construction of the sewage disposal system shall be in accordance with the following conditions: 1. Construction shall conform to Eagle County Individual Sewage Disposal System Regulations. 2. Construction utilizing non-standard materials shall conform to the manufacturer's requirements. 3. The Design Engineer (me) or a qualified Professional Engineer shall inspect and approve the installation of the soil absorption system prior to backfilling. 4. Do not install the soil absorption system in areas where bedrock is located within 4 feet of the bottom of the system. Please give me a call if you have any questions, and please make sure that the system installation contractor contacts me for an inspection prior to backfilling the system. Sincerely, ENARTECH, INC. Peter Belau, P.E. Civil and Environmental Engineer PB/des Enclosures cc: Roger Boyd, Eagle County PM2-01(P342 OIA)92 DESIGN CERTIFICATION: Legal Description: Lot 14, Aspen Mountain View, Second Filing, Eagle County, Co. ENARTECH Inc. Consulting Engineers and Hydrologists August 18, 1992 Mr. Roger Boyd Eagle County Environmental Health Dept. P.O. Box 179 Eagle, CO 81631 A U1011\ RE: ISDS Permit No. 1100-92 Magel Residence Dear Roger: This letter is to certify that the Individual Sewage Disposal System for the Magel residence located at 0297 Green Meadow Drive (Lot #14, Oak Ridge II, Aspen Mountain View Subdivision) has been constructed in accordance with the requirements of ISDS Permit No. 1100-92. The system installation contractor installed a 1250-gallon septic tank and 22 Infiltrator chambers in a bed. The construction meets all requirements. I inspected the system installation on August 12, 1992. Please give me a call if you have any questions. Sincerely, ENARTECH, INC. Peter Belau, P.E. PB/des cc: Bob Magel Joe Zamora P342-01(P34LO7A)92 302 Eighth Street, Suite 325 P.O. Drawer 160 Glenwood Springs, Colorado 81602 (303) 945-2236 EAGLE COUNTY BUILDING 551 BROADWAY P.O. BOX 850 EAGLE. COLORADO 81631 FAX: (303) 328.7207 EAGLE COUNTY, COLORADO FACSIMILE TRANSMITTAL BULLETIN DATE: y/js/yam TO: /g,Gi /'j 1, FROM: TIME: 3 = 3 FAX # gy; -a 1? 7 FAX # (303) 328-7207 _PAGES TO BE TRANSMITTED, INCLUDING THIS COVER PAGE. TYPE OF DOCUMENT: 4_ DELIVER IMMEDIATELY DELIVER WITHIN 4 HOURS ADDRESSEE WILL PICK UP Z_ NOTIFY ADDRESSEE ORIGINAL TO BE MAILED DATE ADDITIONAL INSTRUCTION OR COMMENTS: SENDING OPERATOR: 4� Community Development Department (970) 328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 EAGLE COUNTY, COLORADO October 24, 1997 Clay Wells 0297 Green Meadow drive Carbondale, CO 81623 Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-01.79 RE: Final of ISDS Permit No. 1679-97, Tax Parcel #2391-223-04-001. Property location: 0297 Green Meadow Drive, Carbondale, CO. Dear Mr. Wells: This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. . Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Janet Kohl Environmental Health Department Eagle County Community Development ENCL:Informational Brochure Final ISDS Permit cc: files 2 2 9 n 1%Ca is t' 6L bed n P(o�-n7 deer l tl C*%'F>ked (ni 1-Eyc,4u-s Pe'" tssuesi Mavatn to,1cg7 Drt'f -&c5i 4-c h Veg i Q vv�, utc 2 Ste; Pam Cvwmi t -e I oa,n EA j JOVI p ?cissi bLP 5D i�-i csvt S Q5 4o reel ace i , 0 do 4a^ f4 ow 6,9 do a yids -her lmai -field w;44, a dAVer0i0Y% de., QM o- Av cw`4ir , a o�plza �1 -4-ie , �, Seriatt x11 0 91 I07 V Tax# 2391-223-04-0u <� JOB NAME Oak Ridge II, Lot#14 WELLS .Aspen Mt. View rarhnnrlalo rn aoa rvw Rol ML III DATE STARTE DATE COMPLETED DATE, BILLED iiiiiWE 1 a m 117.2 01 0 , ma. f✓L / / �i.' �_L ��L� �4' �L��/� .' L� /1 l I_, �iLr.l . Ltd L i// �� �� //.No"'M'l �. �./��� � /� L�" �... � / Lam' L� •� / !�L � l/ COST SUMMARY � TOTALJOB TOTAL MATERIAL: -MEN v �Af/ mm ILLF/W-1-0 �1 A _ M I SC. COSTS 1// Ld (�.. FIE ■®® moo. 111111m TAL JOB COST GROSS PROFIT-1 l LESS -OVEHEADSELLING �■ WiMNET PROFIT JOB FOLDER Produg1278 Q® NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MA 01471 Printed in Ui JOB4LOLDER !r� 5/I0/q7 JafL 14"Awcal /Ulekw-t-ly c _