HomeMy WebLinkAbout600 Gypsum Creek Rd - 00000000000INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway • Eagle, Colorado 81631 _
Telephone: 328-8755 J6 P / 0 5.3 �
YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1598
Please call for final inspection before covering any portion of installed system.
OWNER:T)evid and T)Pbra Ma)znp PHONE: (970) 524-9363
MAILING ADDRESS: 1 48 1 VaI I Py Rd _ , City: GV:p cijTn State: en Zip:__ 91637
APPLICANT: Alpine Engineering, Tnc. , T inn Srhnrr PHONE: (70) 926-1171
SYSTEMLOCATION:_-6�mGiim Crppk Rd-9fircUm TAX PARCEL NUMBER: 91 1 1 —1 R1 —no _ni3
LICENSED INSTALLER:_WpGtprn Slone ConcructOrS, Dan Lister LICENSENO: 4--96
DESIGN ENGINEER OF SYSTEM: Ali inp F.n_inPPring, T inn Srbnrr RP$
INSTALLATION HEREBY GRANTED FOR THE FOLLOWING:
2000 GALLON SEPTIC TANK
ABSORPTION AREA REQUIREMENTS:
SQUARE FEET OF SEEPAGE BED 1969 SQUARE FEET OF TRENCH BOTTOM. Via 55 infiltrator units as per design.
SPECIAL REQUIREMENTS: Install as per engineer's design dated May 20, 1996 Engineer is responsible
for final inspection.
ENVIRONMENTAL HEALTH APPROVAL: DATE: May 22, 1996
CONDITIONS:
i. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT
TO AUTHORITY GRANTED IN 25. 10. 104. 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION
TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A
REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
$. CHAPTER IV. SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED.
FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED
PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION ORDISPERSALAREA: 1980 SQUAREFEET. Via 55 infiltrator units as per design
INSTALLED SEPTIC TANK: 3-1000 GALLON 340 DEGREES 25 FEETFROM invert out on North side of bnnG
SEPTIC TANK ACCESS TO WITHIN 9" OF FINAL GRADE AND
PROPER MATERIAL AND ASSEMBLY X YES NO
COMPLIANCE WITH COUNTY / STATE REQUIREMENTS: X YES NO
ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE. FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS CORRECTED.
COMMENTS: Enginee.r final inspection observation rpofiVea9-26-96
ENVIRONMENTAL HEALTH APPROVAL:DATE: el 10"
ENVIRONMENTAL HEALTH APPROVAL: DATE:
(RE-INSPECTION)F NECESSARY)
RETAIN WITH RECEIPT RECORDS
APPLICANT / AGENT:
PERMIT
PERCOLATION TEST FEE
OWNER:
RECEIPT #
CHECK #
ISDS Permit #
Building Permit #_ 16 6 3
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY
P.O. BOX 179
EAGLE, CO 81631
328-8755/927-3823 (Basalt)
PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00
PROPERTY OWNER: David and Debra Mayne
MAILING ADDRESS: 1483 Valley Road, Gypsum, CO 81637 PHONE: (970) 524-9363
APPLICANT/CONTACT PERSON: Alpine Engineering, Inc., Linn SchorrPHONE: (970) 926-3373
LICENSED SYSTEMS CONTRACTOR: Western Slope Constructors, Dan Lister
ADDRESS: P.O. Box 694, Gypsum, CO 81637 PHONE: (970) 524-7585
PERMIT APPLICATION IS FOR: (X) NEW CONSTRUCTION () ALTERATION () REPAIR
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Legal Description: fch'�' 'l ((— (� (� — U z 3
Parcel Number: Lot 1, IK Bar Ranch, Gypsum, Eagle Co. Colorado
Lot size: 36.303 acres
Physical Address:
BUILDING TYPE: (Check applicable category)
(X) Residential/Single Family
() Residential/Multi-Family*
O Commercial/Industrial*
Number of Bedrooms 7
Number of Bedrooms
Type
TYPE OF WATER SUPPLY: Well (X) Spring () Surface ( )
Public () Name of Supplier:
*These systems require design by a Registered Professional Engineer
NOTE: SITE PLAN MUST BE ATTACHED TO APPLICATION
MAKE ALL REMITTANCE PAYA4 O: 'EAGLE COUNTY TREASURER"
SIGNATURE: DATE:
AMOUNT PAID: RECEIPT # / 0 02 �i' d DATE:
CHECK # 9 Fq-7 CASHIER:
Community Development Department
(970) 328-8730
Fax: (970) 328-7185
TDD: (970) 328-8797
EAGLE COUNTY, COLORADO
September 26, 1996
David And Debra Mayne
1483 Valley Rd.
Gypsum, CO 81637
RE: Final of ISDS Permit No. 1598-96, Tax Parcel #2111-181-00-023.
Property location: 600 Gypsum Creek Rd., Gypsum, CO.
Dear Mr. & Mrs. Mayne:
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
This letter is to inform you that the above referenced ISDS Permit has been inspected and
finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance
with any other Eagle County requirements. Also enclosed is a brochure regarding the care of
your septic system.
Be aware that later changes to your building may require appropriate alterations of your septic
system.
If you have any questions regarding this permit, please contact the Eagle County Environmental
Health Division at 328-8755.
Sincerely,
Janet Kohl
Environmental Health Department
Eagle County Community Development
ENCL:Information Brochure
Final ISDS Permit
cc: files
Community Development Department
(970)328-8730
Fax: (970) 328-7185
TDD: (970) 328-8797
EAGLE COUNTY, COLORADO
Date: May 22, 1996
TO: Western Slope Constructors
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 8163 1-0179
FROM: Environmental Health Division
RE: Issuance of Individual Sewage Disposal System Permit No. 1598 -96.
Property Location: 600 Gypsum Creek Rd., Gypsum, CO, Mayne
residence.
Enclosed is your ISDS Permit No. 1598-96. It is valid for 120 days. The enclosed copy of the
permit must be posted at the installation site. Any changes in plans or specifications invalidates
the permit unless otherwise approved.
Systems designed by a Registered Professional Engineer must be certified by the Engineer
indicating that the system was installed as specified. Eagle County does not perform final
inspections on engineer designed systems. Your TCO will not be issued until our office
receives this certification.
Permit specifications are minimum requirements only, and should be brought to the property
owner's attention.
This permit does not indicate conformance with other Eagle County requirements.
If you have any questions, please feel free to contact the Environmental Health Division at 328-
8755.
cc: files
Alpine Engineering, Linn Schorr, R.P.E.
SEPTIC SYSTEM APPLICATION
MAYNE RESIDENCE
LOT 19 IK BAR RANCH
GYPSUM, COLORADO
Prepared for: Western Slope Constructors, Inc.
Dan Lister
P.O. Box 694
Gypsum, CO 81637
Prepared by: Alpine Engineering, Inc.
P.O. Box 97
Edwards, CO 81632
(970) 926-3373
SEPTIC SYSTEM APPLICATION
INTRODUCTION
Lot 1, IK Bar Ranch is a residential property located in the Gypsum Creek drainage, south of
Gypsum, Eagle County, Colorado. The property was formerly ranch land with no
improvements, and is not located within a sanitation district. The owner proposes
construction of a single-family dwelling on the site. It is proposed that an individual sewage
disposal system (ISDS) be installed to serve the proposed development.
PROPOSED USE
The proposed ISDS system will serve a 7 bedroom single-family dwelling.
QUANTITY OF SEWAGE
(7 Bedrooms)(2 persons/bedroom)(75 gpd)(1.5 peaking factor) = 1,575 gpd �
SEPTIC TANK SIZE
1,575 gpd x 30 hrs/day = 1,969 gallons
24 hrs/day
Round to 2,000 gallon total tank capacity. If two 1,000 gallon tanks are used, the first tank in
series shall have no baffle; the second tank in series shall be baffled.
SOILS INVESTIGATION
On May 6, 1996, a soil profile pit was excavated by backhoe in the proposed area of the
absorption system. The following soil profile was observed: from the ground surface to a
depth of approximately 1.7 feet the soil consisted of redish brown loam with little organic
material (this land has been tilled and the natural topsoil structure disturbed and compacted),
followed by a sandy silt with gravel- to cobble -sized rocks extending to the bottom of the pit
at 8 feet. Group wa er was encoun ere ep o eet. Evidence of a seasonal high
water table was not observed.
Percolation tests were performed at the proposed absorption trench location on the same day.
Three test holes were hand -dug to a de th of 1.5 feet. Soils encountered were consistant with
the profile pit and consisted of redish brown loam. Neither groundwater nor evidence of a
seasonal high water table were observed. The average percolation rate of the three holes was
6.5 minutes per inch (MPI). Soils having a percolation rate less than 5 MPI are not suitable
for the disposal of wastewater. The percolation rates in each hole were sufficient.
Due to the shallow groundwater elevation on site, a mound system has been designed.
Infiltrators should be placed at or just below the elevation of the existing ground surface
Application for ISDS Permit 1 Lot 1, IK Bar Ranch
following leveling and scarification to a depth of 3 inches. Soils used to cover infiltrators can
be of variable composition, but should be able to support grass growth.
TRENCH DESIGN
A = Q/5 (T)o.s
A = (1,575 gpd/5) (6.5 mpi)o.s
n
A = 803 SF
Check with loading rate:
For the type of soils found on site, the EPA Design Manual: Onsite Wastewater Treatment
and Disposal Systems recommends a maximum application rate of 0.8 gallons per square foot
per day.
1,575 g12
0.8 gal/ft'
t�
This area will be used for design.
with a 50% reduction for infiltrators = 984 SF
Number of Infiltratoor. Units: n
984 SF 55 Infiltrator Units V
18 SF/Infiltrator— `"'
Length of Trenches:
55 infiltrator units x 6.25 ft./infiltrator unit = 3 trenches at 87.5 ft. long each
4 trenches and 1 trench at 81.25 ft.
MOUND SYSTEM
The area proposed for the absorption lines is relatively flat and will require only minimal
grading to provide a level surface on which to place infiltrators. If infiltrators are placed
directly on the existing ground surface, the native surface should be scarified to aptb_3
inches. The base of the infiltrator units may be placed up to 0.5 feet below the elevation of
th- x sting ground surface to decrease fill required for adequate cover. Native or non-native
materials will be used to cover the infiltrators to a depth of 1.0 - 1.5 feet. The mound will be
appropriately revegetated.
Application for ISDS Permit 2 Lot 1, IK Bar Ranch
DOSING VOLUME
Because the proposed area of the absorption trenches will be topographically higher than the
septic tank inverts, pumps will be required to dose the infiltrators.
- - ._-.1
1,575 ap = 400 gallons per dose
4 doses per day
A 500 gallon dosing tank will be situated down -stream of the septic tank, providing room fore
pumps and appurtanences.
PUMP SYSTEM
The dosing tank will have a volume of 500 gallons and should be sufficient to house the
pumps and appurtanences and provide the dosing volume. A high float switch will trigger
duplexing (alternation) of the two pumps and a low float switch will turn the pumps off at the
end of the dosing cycle. A float switch placed above the high switch will cause both pumps
to start (if one fails the other will pump) and trigger an alarm indicating failure of the pump.
The alarm will be wired to a control panel located in the residential structure to alert the
owners of the need for maintenance. The force main will be installed with a high point so
that at the end of the pumping cycle effluent in the line will gravity drain to the infiltrators or
back into the dosing chamber (via a small hole in the line, located in the tank just above the
pumps). Design of the pumps, electronics and appurtanences will be by others.
APPLICABLE SETBACKS
The proposed location of the septic tank and absorption trenches is outside of all applicable
setback distances. The property will be served by a domestic water well. The well is not yet
installed and should be located at least 146 feet from the absorption trenches and at least 50
feet from the septic tank and lines.
Application for ISDS Permit 3 Lot 1, IK Bar Ranch
ALPINE ENGINEERING, INC.
Mayne Residence ISDS
Percolation Test Results - 5/6/96
TIME
HOLE #1
HOLE #2
HOLE #3
DEPTH (FT.)
MPI
DEPTH (FT.)
MPI
DEPTH (FT.)
MPI
10:25
0.50
0.46
0.45
10:30
0.59
4.63
0.53
5.95
0.54
4.63
10:35
0.67
5.21
0.60
5.95
0.63
4.63
10:40
0.78
3.79
0.66
6.94
0.71
5.21
10:45
0.82
10.42
0.72
6.94
0.79
5.21
10:50
0.88
6.94
0.75
13.89
0.84
8.33
10:55
0.97
4.63
0.80
8.33
0.90
6.94
AVERAGE
5.94
8.00
5.83
y
0
TABLE 7-2
RECOMMENDED RATES OF WASTEWATER APPLICATION
FOR TRENCH AND BED BOTTOM AREAS (4)(11)(12) (a)
SOIL.T, RE Y
,P:ERC,OLATiON RATE
yAPPLICATION RATEb?!'
min/in
gpd/ft (2)
Gravel, coarse sand
<1
Not Suitable (`)
Coarse to medium sand
1-5
Fine sand, loamy sand
6 -15
0.8
Sandy loam, loam
16 - 30
Loam, porous silt loam
31 - 60
0.45
Silty clay loam, clay loam (d)
61 - 120
0.2 (e)
a. May be suitable estimates for sidewall infiltration rates.
b. Rates based on septic tank effluent from a domestic waste source.
A factor of safety may be desirable for wastes of significantly
different character.
c. Soils with percolation rates <1 min/in can be used if the soil is
replaced with a suitably thick (>2 ft) layer of loamy sand or
soil.
d Soils without expandable clays.
e. These soils may be easily damaged during construction.
EPA Design Manual: Onsite Wastewater Treatments and Disposal
Systems.
ISDS PERMIT: 5 �1 _ (e,
v � Al M '^ {}' 11 s 11) �, I I t;7�j g�i9 Til ®rLl
ISDS F1NAL4NSPECTt09V'
COMPLETENESS FORM
a1Z0_:':1Tank ism 0Ogal. Tank Material: V--ff - c—QV ce-j-
� i�
M
DATE: IiO
Tank is located 25� ft. and _-,1 -0" degrees
(permanent landmark)
V , I 1 PoS ir-0� Y C,G
t/ Tank is located Z $ ft. andgg'' degrees from N� Y\\o „gQ C 0YVIZ
(permanent landmark)
V Tank set level. \-0 AL T4nk lids within 81" of finished r$(rade. n
� / Size of field j'1 b ft' J S units lineal ft. ,
Technology : �
V/Cleanout is installed in between tank and house (+ Ii 100 ft)
—,/ There is a "T" that goes down 14 inches in the inlet and outlet of the tank.
\/ Inlet and outlet is sealed with tar tape, rubber gasket, etc. .
Tank has two comi:a�rents with the larger compartt se clo'fo,the house.
S t,^ p ism+ 't
_--Measure distance and relative direction to field. �� 1
V Depth of field I , � ft.
0) t6&o
a 4t#hk!;
Soil interface raked. nn °'�-•
Inspection portals at the end of each trench.
V/Proper distance to setbacks.
_Chambers properly installed per manufacturers specifications. (Chambers latched, end plates properly installed,
rocks removed from trenches, etc.)
Other:
V Inspection meets requirements.
Copy form to installer's file if recommendations for improvement were suggested.
ACTION TAKEN:
Setbacks
2M3
o
� r
r®o
Well
Potable Water
Lines
House
Property
Line
Lake
Stream
Dry Gulch
Tank
Drain
Field
100
25
20
10
50
25
10
10
Tank
50
10
5
10
50
10
*
10
Cbr_,e, vot 4nnn L11 1"1470% v
PbIMH
'Dyes—vb Taxg 2111-181-00-023
Lot#I,IK Bar Ranch MAYNE
JOB NAME _ 600 Gypsum Creek Rd.
Gypsum, CO
OB LOCATION
BILL TO
DATE STARTDATE
COMPLETED
DATE BILLED
J 41111
_- - 0,
` -
JOB COST SUMMARY
`
TOTAL SELLING PRICE
TOTAL MATERIAL
TOTAL LABOR
INSURANCE
SALES TAX
MISC. COSTS
TOTAL JOB COST
GROSS PROFIT
LESS OVERHEAD COSTS
OF SELLING PRICE
NET PROFIT
JOB FOLDER Product 278 ®, NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MA 01471 JOB FOLDER Printed in U.S.A.