HomeMy WebLinkAbout22544 Colorado River Rd - 168522201001INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, Colorado 81631 Telephone: 328-8755 8P 11a13 °7 YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1509 Please call for final inspection before covering any portion of installed system. OWNER: Carl Hampton PHONE: (970) 653-4365 MAILINGADDRESS: P.O. BOX 75 City: Burns State: CO zio:80426 APPLICANT: Richard Battey PHONE: _ (970) 653-4365 SYSTEMLOCATION: 22543 Colorado River Rd. , Burns TAX P RCELNUMBER: 1685-222-00-002 Derek Co., LICENSED INSTALLER: T.a nrl c r �� !' c a -^•• + L CE1 NSE NO: :L9-- b�3Qf� DESIGN ENGINEER OF SYSTEM: INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: 1250 GALLON SEPTIC TANK ABSORPTION AREA REQUIREMENTS: SQUARE FEET OF SEEPAGE BED 1125 SQUARE FEET OF TRENCH BOTTOM. via 32 infiltrators as per design. SPECIAL REQUIREMENTS: Install as .per engineer's design dated 3129/96 ENVIRONMENTAL HEALTH APPROVAL: DATE: CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY ALL REQ OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25- 10. 104. 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM.. INSTALLED ABSORPTION OR DISPERSAL AREA: 1 1.a ` SQUARE FEET. INSTALLED SEPTIC TANK: 17-� GALLON N Z5-0 DEGREES 1� FEET FROM S�S-Ct(.6Y0\t-,✓ SEPTIC TANK ACCESS TO WITHIN 8" OF FINAL GRADE AND PROPER MATERIAL AND ASSEMBLY VYES NO COMPLIANCE WITH COUNTY/ STATE REQUIREMENTS: ✓YES NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS CORRECTED. COMMENTS: ENVIRONMENTAL HEALTH APPROVAL: - DATE: ENVIRONMENTAL HEALTH APPROVAL: DATE: (RE -INSPECTION IF NECESSARY) RETAIN WITH RECEIPT RECORDS APPLICANT / AGENT: OWNER: PERMIT FEE PERCOLATION TEST FEE ____ ___ RECEIPT # CHECK # 11 (Site Plan MUST be attached) ISDS Permit # —�J APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. O. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (El Jebel) ************************************************************************** * PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 * * * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" PROPERTY OWNER: MAILING ADDRESS: APPLICANT/CONTACT MAILING ADDRESS: � / LICENSED ISDS ONTRACTOR: 7WI,//�rBi 3 COMPANY/DBA: P-45nG" ADDRESS: PHONE: *************************************************************************** PERMIT APPLICATION IS FOR: (tef New Installation ( ) Alteration ( ) Repair *************************************************************************** LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Building Permit # (if known) �` Y4. by w l� Ntuy� 87i Legal Description: Subdivision:S EL alT�, gFilin `u) Filling:_. Lot 14 Tax Parcel Number: - - _ � � Lot Size:._"f Street Address: _2 a S q :3 C c *************************************************************************** BUILDING TYPE: (Check applicable category) (14 Residential/Single Family ( ) Residential/Multi-Family* ( ) Commercial/Industrial* TYPE OF WATER SUPPLY: (Check applicable category) Well (1-1 Spring ( ) Surface Public Name of Supplier: Number Number Type _ of Bedrooms of Bedrooms *These systems require desig by Regis ered Professional Eng'ne r P � SIGNATURE: - Date: pow ********** TO BE COMPLEyTTy�EttD, BY TH COUNTY AMOUNT PAID :y RECEIPT #: /oo�� 7 DATE: �1 CHECK #: ScS� CASHIER: ALPINE ENGINEERING INC FACSIMILE TRANSNUSSION: Edwards Busincss C ent`r1P.U, lists 97 Edx%ards, CO 81632 111-1: (970) 926-3373 FAX: (970) 9:6-3399 Date: 4):.-k!�F- , Tinte: Job: 05- To: To: Co; Co: 32. ►`� Fax n: Fax #: To - Ca Fax #: To: Co: Fax From: To: Co: Fax 4. Tot Co: Fax tt: (If there are any problems concerning this FAX please call Marian or Nicki at 926-3373) Number of Pages (including cover sheet): Transmitted: for approval as requested for review and comment for your rec4r revie-, ed other for your use Confidentiality Statement: This facsimile transmission and any accompanying documents contain information belonging to the sender which may be confidential and legally privileged. This information is intended only for the use of the individual or entity to whom this facsimile transmission was sent as indicated above. If you are not the intended recipient, any disclosure, copying., distribution or action taken in reliance on the contents of the information contained in the facsimile is strictly prohibited. If you have received this transmission in error, ...all „e r 11—r 4n %rr-An6r fAr thr. romm of the documents to us at our exDcnse. Thank vou. ALPINE ENGINEERING, INC. Community Development Department (970) 328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 , EAGLE COUNTY, COLORADO December 2, 1996 Mr. Carl Hampton P.O. Box 95 Burns, CO 80426 RE: Building Permit # 7037 Misc. # 02145 22543 Colorado River Road Dear Carl: Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 Enclosed are your issued building permits under the above numbers for the property at 22543 Colorado River Road, also known as Derby Junction. These permits are for the main house and the six cabins. Your building permit extension expires on Thursday, December 19, 1996. Upon receipt of these permits, it will be in your best interest to have inspections of the house and cabins before the building permits expire. We understand that your septic system is awaiting final inspection and can be approved by Alpine Engineering shortly. The house and cabins can be inspected before the septic system is finaled. You may call our Inspection Request Line at 328-8106 to schedule the inspections. If you are unable to call for inspections before the permits expire, please send or bring in a letter requesting another 6 month extension. However, please continue to make the necessary repairs - to the septic system so it can be finaled as soon as possible. Keep in mind that until the ISDS permit and building permits are signed and finaled, it is unlawful to occupy the house or cabins without a T.C.O. or C.O. The sooner these inspections are completed and signed, the quicker we can issue your Certificate of Occupancy. Page Two Re: Carl Hampton December 2, 1996 If you have any questions regarding this enforcement action, please contact me at 328-8747. Sincerely, EAGLE COUNTY COMMUNITY DEVELOPMENT DEPARTMENT Bruce Campbell Code Enforcement Officer enclosures cc: Keith Montag Mike Wheelersburg Building File # 7037 Code Enforcement File # VZ-9506-07 SEPTIC SYSTEM APPLICATION BATTEY RESIDENCE BURNS, CO Prepared for: The Derby Creek Company Richard Battey P.O. BOX 75 Burns, CO 80426 Prepared by: Alpine Engineering, Inc. P.O. BOX 97 Edwards, CO 81632 (970) 926-3373 SEPTIC SYSTEM APPLICATION INTRODUCTION The Derby Creek Company is a residential/commercial property located in the NW 1/4 of Section 22, T2S, R85W, 6th P.M., in the Colorado River drainage near Burns, Eagle County, Colorado. The existing house on site is currently served by an on -site individual sewage disposal system. This system is old and not permitted with Eagle County. This area is not served by Upper Eagle Valley Consolidated Sanitation District. It is proposed that the existing ISDS serving the Battey Residence on site be properly abandoned and a new system designed and permitted to bring the residence into compliance with Eagle County regulations. PROPOSED USE The Battey Residence is a four (4) bedroom residential single family dwelling. QUANTITY OF SEWAGE (4 Bedrooms)(2 persons/bedroom)(75 gpd)(1.5 peaking factor) = 900 gpd SEPTIC TANK SIZE 900 gpd x 30 hrs/day = 1,125 gallons 24 hrs/day Round to 1,250 gallon capacity tank. SOILS INVESTIGATION On January 11, 1996, a soil profile pit was excavated by backhoe in the proposed area of the absorption system. The following soil profile was observed: from the ground surface to a depth of approximately 3 feet the soil consisted of a dark brown loamy silt with sand and clay, followed by a light brown sandy silt with some cobbles to the extent of the excavation at a depth of 10 feet. Neither groundwater nor evidence of a seasonal high water table was encountered in the profile pit. At the time of observation, soils in the upper soil layer were partially frozen precluding the collection of useful information from a percolation test. Assuming that the infiltrator units will sit within the lower soil layer (grade will have to be lowered 1 to 2 feet to provide for gravity feed), at a depth below the finished ground surface of 2.25 feet, a long term acceptance rate of 0.8 gallons per square foot per day (gpd/sq.ft.) and a percolation rate of 10 minutes per inch (MPI). Application for ISDS Permit 1 Battey Residence TRENCH DESIGN A = Q/5 (T)0.s A = (900 gpd/5) (10 mpi)o.s A = 569 SF Check with loading rate: For the type of soils found on site, the EPA Design Manual: Onsite Wastewater Treatment and Disposal Systems recommends a maximum application rate of 0.8 gallons per square foot per day. 900 apd = 1,125 ft2 0.8 gal/ft2 This area will be used for design. with a 50% reduction for infiltrators = 562 SF Number of Infiltrator Units: 562 SF = 32 Infiltrator Units 18 SF/Infiltrator Length of Trenches: 32 infiltrator units x 6.25 ft./infiltrator unit = 2 trenches at 68.75 ft. long each 3 trenches and 1 trench at 62.5 ft. long APPLICABLE SETBACKS The proposed location of the septic tank and absorption trenches is outside of all applicable setback distances. The trailer located by the house, adjacent to the proposed absorption trench area, will be moved out of this general area prior to construction of the ISDS. Application for ISDS Permit 2 Battey Residence BATTEY RESIDENCE ISDS PROPOSED LAYOUT GENERAL NOTES CONTACT ALPINE ENGINEERING, INC. AT LEAST 48 HOURS PRIOR TO INSTALLING ANY SEPTIC SYSTEM IMPROVEMENT. THE SEPTIC SYSTEM IS ALSO TO BE INSPECTED BY ALPINE ENGINEERING, INC. PRIOR TO BACKFILL. CONTACT LINN SCHORR, 926-3373. 2. ALIGN TRENCHES PARALLEL TO CONTOURS TO MAINTAIN COVER. CONSULT CIVIL ENGINEER DURING INSTALLATION IF NECESSARY. PROVIDE MINIMUM 10' SEPARATION BETWEEN WATER AND SEWER LINES, OR ENCASE PER EAGLE COUNTY REGULATIONS. 4. COMPACT SEWER TRENCHES TO 90% STANDARD PROCTOR DENSITY, OR PER SOILS ENGINEER'S RECOMMENDATIONS. PROVIDE RISERS ON SEPTIC TANKS TO FINISH GRADE. 6. PROVIDE INSPECTION PORTALS PER EAGLE COUNTY REGULATIONS. 7. MAINTAIN MINIMUM GRADE ON SERVICE LINES AND 3 FEET COVER OR PROVIDE INSULATION. COVER OVER INFILTRATORS SHOULD BE NOT LESS THAN 12" AND NOT GREATER THAN 18" PER MANUFACTURER'S SPECIFICATIONS. 8. PROVIDE 6' MINIMUM BETWEEN INFILTRATOR TRENCH WALLS. 9. CONSTRUCT AND LEVEL TEES AND OVERFLOWS SO THAT FIRST TRENCH FILLS, THEN OVERFLOWS TO SECOND TRENCH, ETC. TO PROVIDE SERIAL DISTRIBUTION. 10. DIRECT DRAINAGE FROM ROOFS AND SURROUNDING AREAS AWAY FROM ABSORPTION TRENCHES. 11. PROVIDE TWO TIES TO SEWER CLEANOUTS, SEPTIC TANK, AND ABSORPTION TRENCH CORNERS, AS REQUIRED BY EAGLE COUNTY FOR AS-BUILTS. 12. WE RECOMMEND THAT THE DISPOSAL FIELD BE SEEDED AFTER INSTALLATION OF THE SUBSURFACE DISPOSAL SYSTEM TO PROMOTE EVAPOTRANSPIRATION. RECOMMENDED SEED MIXES INCLUDE "FOOTHILL PASTURE" OR "PRAIRIE", WHICH ARE AVAILABLE LOCALLY AND GROW TO 10" AND 15" HIGH. NO AUTOMATIC SPRINKLER SYSTEM SHOULD BE INSTALLED ABOVE THE DISPOSAL FIELD. 13. THE OWNER MUST REALIZE THAT AN ONSITE SEWAGE DISPOSAL SYSTEM IS CONSIDERABLY DIFFERENT FROM PUBLIC SEWER SERVICES. THE OWNER MUST BE AWARE OF AND ASSUME THE RESPONSIBILITY FOR CONTINUED MAINTENANCE OF THE SYSTEM. WE RECOMMEND PUMPING OF THE SEPTIC TANK AT THE END OF THE FIRST YEAR OF USE TO MONITOR SLUDGE ACCUMULATION AND AT A MINIMUM OF EVERY TWO YEARS AFTERWARD. THERE ARE ALSO DAILY CONSIDERATIONS. SUCH AS NOT PUTTING PLASTIC OR OTHER NONBIODEGRADABLE MATERIAL DOWN THE SEWAGE DISPOSAL SYSTEM. ALSO, WATER USE MUST BE CAREFULLY MONITORED SO TOILETS ARE NOT ALLOWED TO RUN WHEN SEALS MALFUNCTION. TO ILLUSTRATE THE POINT, IT SHOULD BE NOTED THAT A RUNNING TOILET WILL CONSUME IN EXCESS OF 1000 GALLONS PER DAY IF ALLOWED TO RUN. EXCESSIVE LOADING (SUCH AS FROM RUNNING TOILETS) WILL FLOOD AND IRREVOCABLY HARM THE SYSTEM, AND STRESS THE ONSITE WELL. 14. ENSURE THAT VEHICLES ARE NOT ALLOWED TO DRIVE ACROSS THE TANK, LINES OR INFILTRATORS. PLACE POSTS OR BARRIERS IF NECESSARY. 15. COMPLY WITH ALL EAGLE COUNTY REGULATIONS REGARDING SEPTIC SYSTEM INSTALLATION. INSTALL INFILTRATOR SYSTEM PER MANUFACTURERS RECOMMENDATIONS AND EAGLE COUNTY HEALTH DEPARTMENT REQUIREMENTS. EAGLE COUNTY WILL NOT APPROVE THE SEPTIC SYSTEM UNTIL AS-BUILTS ARE SUBMITTED. 16. CONTRACTOR IS RESPONSIBLE FOR PROVIDING AS -BUILT DRAWINGS TO ENGINEER FOR FINAL INSPECTION. ISDS PERMIT: 15Oa DATE: ct AeMCP-- ISDS FINAL OBSERVATION / \ COMPLETENESS FORM V Tank is 50 al. Tank Material: eve_ -tAS Gati-cre e. Tank is located ""t ft. and N ZSO� degrees from S� uSP_ Cps-Y1��C^ (permanent landmark) o y Tank is located ft. and degrees from C\eAY\ 0kk� (permanent landmark) V Tank set level. Tank lids within 8" of finished grade. %/ Size of field ftZ 32 units 2.,00 lineal ft. Technology S•n a�}ors V Cleanout is installed in between tank and house (+ 1/100 ft) ' There i$ a "T" that goes down 14 inches in the inlet and outlet of the tank. V Inlet and outlet is sealed with tar tape, rubber gasket, etc. *o`it�s„Brrrnn a,`0�t�` ,0 REG/S Tank has two compartments with the larger compartment closest to the house. ti F•11060q•,jE ,ice y Measure distance and relative direction to field. 10, tQ ITzZ ` ��•� �a L _SDepth of field ft. V" Soil interface raked. �; ••• •$ / r V Inspection portals at the end of each trench. Proper distance to setbacks. V Chambers properly installed per manufacturers specifications. (Chambers latched, end plates properly installed rocks removed from trenches, etc.) Other: V Inspection meets requirements. Copy form to installer's file if recommendations for improvement were suggested. ACTION TAKEN: Setbacks Well Potable Water Lines House Property Line Lake Stream Dry Gulch Tank Drain Field 100 25 20 10 50 25 10 10 Tank 50 10 5 10 50 10 * 10 PROPOSED ISDS LAYOUT BEATTY RESIDENCE 4'I i IIL 0 CYoss SeG�; Oln\ Glreuwt� ='.'* sa ZE PANT TOP t' or Pm IO M s�oml � camkr tb scosxanws WE .nr Aw avow (AU. K L nn"o" SEWER CLEAN -OUT DETAIL V d.e be..JNCr wo�L\ S recesS. �Z.So z' 1 =v.�,��tra�0•r-'� t`�GvcS — \� V�v�� � 0 M�S�XV0.'�.py1 =..k,,es — \\ W^:%�cs lo' ' Mi►J F—F-= \OO,OOI 'j7:S�'••��n�i o v� * � Cjev'ex-d.\ ALPINE ENGINEERING INC. EDWARDS BUSINESS CENTER • P.O. BOX 97 EDWARDS, COLORADO 81632 • 970 926-3373 a FAX 926-3390 QIU l_w 1509-95 Tax#1685-222-00-002 1 /' JOB NAMI 22543 Colorado River Rd. f� JOB NO.�T c' Burns, CO 80426 HAM ON Derby J_uziction�w_-_ . _. Insa I nr•eTinni Pl 4,Sf) - 44 0 S( jr1w BILL TO 31 All _ DATE. STARTED DATE COMPLETED F DATE BILLED /-%� �"t✓� [ i/ %� 71t , S U C 11 C SC r� /C'� C� ss 7K vc — GULL S w �1-1�-C D 6c / 7`v f JOB COST SUMMARY k Z t, Id s- o L*- 3 a TOTAL SELLING PRICE A! 'TOTAL MATERIAL TOTAL LABOR 10 0 �7 ti INSURANCE SALES TAX MISC. COSTS TOTAL JOB COST GROSS PROFIT LESS OVERHEAD COSTS % OF SELLING PRICE NET PROFIT JOB FOLDER Product 278 ®e NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MA 01471 JOB,FOLDER Printed in U.S.A. a INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, Colorado 81631 Telephone: 328-8755 YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1562 Please call for final inspection before covering any portion of installed system. OWNER: Richard Battey PHONE: (970) 653-4365 MAILINGADDRESS: P.O. BOX 75 city:_ Burns State: CO Zip: 80426 APPLICANT: Alpine Engineering, Inc. PHONE: (970) 926-3373 SYSTEMLOCATION: 22543 Colorado River Rd Burns TAX PARCEL NUMBER: 1685-222-00-002 LICENSED INSTALLER:_ Derby Creek Co , Richard Battey LICENSE NO: 15-96 DESIGN ENGINEER OF SYSTEM: Aline Engineering, Linn Schorr__ INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: 2-1500 GALLON SEPTIC TANKS ABSORPTION AREA REQUIREMENTS: SQUARE FEET OF SEEPAGE BED 2071 SQUARE FEET OF TRENCH BOTTOM. SPECIAL REQUIREMENTS: Tngtall as ner anginaarlg design dated4-26 Q6 Serially distribute trenrhps and alternate dosing to the 1st and 3rd trenches Engineer is rpaponsible for final inGnert• ENVIRONMENTAL HEALTH APPROVAL: DATE: May 28,19q6 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25- 10- 104. 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED M. NSIOR IL ABSAB oERPNG ANR DIO RTIERSALOREA;THE SYSTEM SQUARE FEET. INSTALLED SEPTIC 1 I GALLON_ DEGREES _ f'�_ FEET FROM YI W T Y I SEPTIC TANK ACCESS TO WITHIN 8" OF FINAL GRADE AND PROPER MATERIAL AND ASSEMBLY YES _ NO COMPLIANCE WITH COUNTY/STATE REQUIREMENTS: YES NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS CORRECTED. COMMENTS: ENVIRONMENTAL HEALTH APPROVAL: DATE: J ENVIRONMENTAL HEALTH APPROVAL: DATE: (RE -INSPECTION IF NECESSARY) RETAIN WITH RECEIPT RECORDS APPLICANT / AGENT: OWNER: PERMIT FEE PERCOLATION TEST FEE RECEIPT # CHECK # ISDS Permit # Building Permit # APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P.O. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (Basalt) PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 PROPERTY OWNER: Mr. Carl Hampton MAILING ADDRESS: P.O. Box 75. Burns, CO 80426 PHONE:_ (970) 653-4365 APPLICANT/CONTACT PERSON: Alpine Engineering. Inc. -PHONE: (970) 926-3373 LICENSED SYSTEMS CONTRACTOR: Richard Battey ADDRESS: P.O. Box 75, Burns, CO 80426 PHONE: (970) 653-4365 PERMIT APPLICATION IS FOR: (X) NEW CONSTRUCTION () ALTERATION () REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description:NW 1/4, Section 22, T2S, R85W, 6th PM, Eagle Countv Colorado Parcel Number: See land survey. attached. /G gs- - aaa - 00 B oa Lot size: approximately 56 acres Physical Address: 22543 Colorado River Road, Burns BUILDING TYPE: (Check applicable category) () Residential/Single Family () Residential/Multi-Family* (X) Comm ercial/Industrial* Number of Bedrooms Number of Bedrooms Type boarding cabins, laundry and shower facilities, general store TYPE OF WATER SUPPLY: Well () Spring (X) Surface ( ) Public ( ) Name of Supplier: *These systems require design by a Registered Professional Engineer NOTE: SITE PLAN MUST BE ATTACHED TO APPLICATION MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" SIGNATURE: DATE: ******************************** AMOUNT PAID 6-0-00 RECEIPT # !Q 9 y 7 A DA CHECK # S9 CASHIER: as requested ALPINE [ dwartis Business C cittrr\P.U, Box 97 Eduardo, CO 81632 ENGINEERING INC 111-1: (970) 926-3373 FAX: (970) 4:6.3394 FACSIMILE TRANSN[ISSION: Date: Time: Job: \ s� To: To: Co: Co: Fax 9: 3z fit` S- Fax ': To: Co! Fax #: To: Co: Fax +�*: From: _ To: Co: Fax fr: To: Co: _ Faxn: r^ (if there are any problems concerning this FAX please call %4arian or Nicki at 926-3373) Number of Pries (including cover sheet): Transmitted: for approval for review and comment revie-, ed for your use other Confidentiality Statement: This facsimile transmission and any accompanying documents contain information belonging to the sender which may be confidential and legally privileged. This information is intended only for the use of the individual or entity to. whom this facsimile transmission was sent as indicated above. If you are not the intended recipient, any disclosure, copying, distribution or action taken in reliance on the contents of the information contained in the facsimile is strictly prohibited. If ),ou have received this transmission in error, _i____ __ti ....,,.it-........,.,. _ r . #I,. ...*­_ .,f el.n AnrnmRnte M im at nllr ranrnse_ Thank vM]. ALPINE ENGINEERING. INC. TAYLE 7-2 RECOKKENDED RATES OF WASTEWATER APPLICATION FOR TREKH AND FED BOTTOM AREAS (4) (11) 0 2 �a Percolaxion Soil Texture _ Rate A.pplicatiori Ra teb mi n/i n. g�dlft2 Gravel, coarse sand <1 Not suitablec : Coarse t.o nedium sand 1 - 5 1.2 Fine sand, loa--.y sand 6 - 15 0.8 Sandy'loam, loam 16 - ::0 ;,so Loam, Fc-c,us silt l cam 31 - 60 0.45 _Silty clay Iran, clayploard F1 - 120 0,2e a ?!3y be suitable estimates for sidewall infiltration rates. b Rates• based on septic tank effluent from a domst"c. waste source. A factor of safety ray be desirable for ,istes cf : significantly different character. c Soils with percolation rates <1 ., n/in. can be used soil is replaced with if the a suitably ttiick (>2 ft) layer sand or sand. of loary d Soils without expandable days. e These soils ray be easily daraged during constructiun. • 214 CONVENTIONAL SYSTEM MODIFICATIONS 119 ,ipes should be at least urrs on the inside of the ou can be sure that the than one -eighth inch is of plugging. Three - the smallest size holes three -eighths inch in or the need for a large >t can result in seepage ;e 4 ft for a place to start as follows: teral (ft) _ hole !e of the lateral, if the dosing chamber, there �e bottom of the supply Figure 4.6). This hole is mber will not siphon to k the pump is running, this hole and back into shing on the water, and per square inch (psi). A sure of 0.43 psi. There teral holes, with 3 ft of ;th of the laterals and in the laterals, and the osing rate should be at use and 30 gal per min these can result in un- nd. The design dosing Free steps: Table 6.5 Flow Rates Through Holes of Various Diameters (gpm) Pressure Head (ft) 3/32 1/8 Hole Diameter (in.) 5/32 3/16 7/32 1 0.10 0.18 0.29 0.4 0.56 2 0.15 0.26 0.41 0.59 0.80 3 0.18 0.32 0.50 0.72 0.98 4 0.21 0.37 0.58 0.83 1.13 5 0.23 0.41 0.64 0.94 1.26 Calculation of the number of holes was discussed earlier. Determining the flow rate per hole involves using Table 6.5. Begin by assuming a pressure head of 3 ft at the distribution laterals and a hole diameter of three -sixteenths inch. This gives a flow rate of 0.72 gal per min per hole. The total dosing rate is simply the dosing rate per hole times the number of holes. As an example, assume: length per lateral leg = 25 ft no. of lateral legs = 6 hole diameter = 3116 in. hole spacing = 4 ft pressure head at laterals = 3 ft 1. No. of holes = length per lateral x no. of laterals 25 ft x 6 = 38 holes hole spacing 4 ft 2. Flow rate per hole (from Table 6.5) = 0.72 gpm 3. Total dosing rate = no. of holes x flow rate per hole = 38 x 0.72 gpm = 27 gpm A dosing rate of 27 gal per min is about right. If flow rates more than double the minimum are projected, it may be desirable to reduce the rate somewhat in order to be able to use a smaller pump or smaller diameter pipe. The hole spacing can be increased or the hole diameter decreased. It is usually better to use wider hole spac- ing in order to be spared the plugging that occurs with small holes. Pipe diameters can be selected once the total dosing rate is known. Using Table 6.6, the minimum diameter of the laterals can be deter- mined. For example, using 4-ft spacing of three -sixteenths -inch 1 '&'v(E pe' �oo f e 95' ` 93 Lvote.s les x Az or" l �t�V �� �� C�;r'facci DERBY CREEK COMPANY C0:17MERCIAL ISDS PROPOSED LAYOUT GENERAL NOTES 1. CONTACT ALPINE ENGINEERING, INC. AT LEAST 48 HOURS PRIOR TO INSTALLING ANY SEPTIC SYSTEM IMPROVEMENT. THE SEPTIC SYSTEM IS ALSO TO BE INSPECTED BY ALPINE ENGINEERING, INC. PRIOR TO BACKFILL. CONTACT LINN SCHORR, 926-3373. 2. ALIGN TRENCHES PARALLEL TO CONTOURS TO MAINTAIN COVER. CONSULT CIVIL ENGINEER DURING INSTALLATION IF NECESSARY. 3. PROVIDE MINIMUM 10' SEPARATION BETWEEN WATER AND SEWER LINES, OR ENCASE PER EAGLE COUNTY REGULATIONS. 4. COMPACT SEWER TRENCHES TO 90% STANDARD PROCTOR DENSITY, OR PER SOILS ENGINEER'S RECOMMENDATIONS. 5. PROVIDE RISERS ON SEPTIC TANKS TO FINISH GRADE. 6. PROVIDE INSPECTION PORTALS PER EAGLE COUNTY REGULATIONS. 7. MAINTAIN MINIMUM GRADE ON SERVICE LINES AND 3 FEET COVER OR PROVIDE INSULATION. COVER OVER INFILTRATORS SHOULD BE NOT LESS THAN 12" AND NOT GREATER THAN 18" PER MANUFACTURER'S SPECIFICATIONS. 8. PROVIDE 6' MINIMUM BETWEEN INFILTRATOR TRENCH WALLS. 9. CONSTRUCT AND LEVEL TEES AND OVERFLOWS SO THAT FIRST TRENCH FILLS, THEN OVERFLOWS TO SECOND TRENCH, ETC. TO PROVIDE SERIAL DISTRIBUTION. 10. DIRECT DRAINAGE FROM ROOFS AND SURROUNDING AREAS AWAY FROM ABSORPTION TRENCHES. 11. PROVIDE TWO TIES TO SEWER CLEANOUTS, SEPTIC TANK, AND ABSORPTION TRENCH CORNERS, AS REQUIRED BY EAGLE COUNTY FOR AS-BUILTS. 12. WE RECOMMEND THAT THE DISPOSAL FIELD BE SEEDED AFTER INSTALLATION OF THE SUBSURFACE DISPOSAL SYSTEM TO PROMOTE EVAPOTRANSPIRATION. RECOMMENDED SEED MIXES INCLUDE "FOOTHILL PASTURE" OR "PRAIRIE", WHICH ARE AVAILABLE LOCALLY AND GROW TO 10" AND 15" HIGH. NO AUTOMATIC SPRINKLER SYSTEM SHOULD BE INSTALLED ABOVE THE DISPOSAL FIELD. 13. THE OWNER MUST REALIZE THAT AN ONSITE SEWAGE DISPOSAL SYSTEM IS CONSIDERABLY DIFFERENT FROM PUBLIC SEWER SERVICES. THE OWNER MUST BE AWARE OF AND ASSUME THE RESPONSIBILITY FOR CONTINUED MAINTENANCE OF THE SYSTEM. WE RECOMMEND PUMPING OF THE SEPTIC TANK AT THE END OF THE FIRST YEAR OF USE TO MONITOR SLUDGE ACCUMULATION AND AT A MINIMUM OF EVERY TWO YEARS AFTERWARD. THERE ARE ALSO DAILY CONSIDERATIONS. SUCH AS NOT PUTTING PLASTIC OR OTHER NONBIODEGRADABLE MATERIAL DOWN THE SEWAGE DISPOSAL SYSTEM. ALSO, WATER USE MUST BE CAREFULLY MONITORED SO TOILETS ARE NOT ALLOWED TO RUN WHEN SEALS MALFUNCTION. TO ILLUSTRATE THE POINT, IT SHOULD BE NOTED THAT A RUNNING TOILET WILL CONSUME IN EXCESS OF 1000 GALLONS PER DAY IF ALLOWED TO RUN. EXCESSIVE LOADING (SUCH AS FROM RUNNING TOILETS) WILL FLOOD AND IRREVOCABLY HARM THE SYSTEM, AND STRESS THE ONSITE WELL. 14. ENSURE THAT VEHICLES ARE NOT ALLOWED TO DRIVE ACROSS THE TANK, LINES OR INFILTRATORS. PLACE POSTS OR BARRIERS IF NECESSARY. 15. COMPLY WITH ALL EAGLE COUNTY REGULATIONS REGARDING SEPTIC SYSTEM INSTALLATION. INSTALL INFILTRATOR SYSTEM PER MANUFACTURERS RECOMMENDATIONS AND EAGLE COUNTY HEALTH DEPARTMENT REQUIREMENTS. EAGLE COUNTY WILL NOT APPROVE THE SEPTIC SYSTEM UNTIL AS-BUILTS ARE SUBMITTED. 16. CONTRACTOR IS RESPONSIBLE FOR PROVIDING AS -BUILT DRAWINGS TO ENGINEER FOR FINAL INSPECTION. SEPTIC SYSTEM APPLICATION DERBY CREEK COMPANY BURNS, CO COMMERCIAL ISDS �0&00 REG/S crP•,.....•• F,Q D - PAS •. F ;W B��eeyy 3 �. %0 2275 • Prepared for: The Derby Creek Company Carl Hampton P.O. Box 75 Burns, CO 80426 Prepared by: Alpine Engineering, Inc. P.O. Box 97 Edwards, CO 81632 (970) 926-3373 SEPTIC SYSTEM APPLICATION INTRODUCTION The Derby Creek Company is a residential/commercial property located in the NW 1/4 of Section 22, T2S, R85W, 6th P.M., in the Colorado River drainage near Burns, Eagle County, Colorado. Commercial buildings on the site are currently served by an on -site individual sewage disposal system (ISDS). This system is old and not permitted with Eagle County. This area is not served by Upper Eagle Valley Consolidated Sanitation District. It is proposed that the existing ISDS system be properly abandoned and a new system designed and permitted to bring the commercial operation into compliance with Eagle County regulations. PROPOSED USE The proposed ISDS system will serve 6 commercial cabins to be used by river rafters. Each cabin has one bed room, one bathroom and kitchenette facilities. In addition, a laundry and shower facility will be available to Derby Creek customers, and, at some future time, an existing building on the site may be used as a store. QUANTITY OF SEWAGE Cabins: (6 Bedrooms)(2 persons/bedroom)(75 gpd)(1.5 peaking factor) = 1,350 gpd Laundry facility: (19.5 gpd)(6 persons)(1.5 peaking factor) = 175 gpd Shower facility: (14.7 gal. per shower use)(4 showers/day)(1.5 peaking factor) = 88 gpd Store: (2 employees)(15 gpd/employee)(1.5 peaking factor) = 45 gpd TOTAL 1,658 GPD This estimate is felt to be conservative. SHOWER AND LAUNDRY FACILITIES ARE NOT PUBLIC. USE OF THESE FACILITIES SHOULD BE MONITORED AND NOT ALLOWED TO EXCEED THE DESIGN CAPACITY. "Note that the store is across Eagle County Road 39 from the septic system. Crossing of the road with the sewer line will require a county road cut permit. SEPTIC TANK SIZE 1,658 gpd x 30 hrs/day = 2,072 gallons 24 hrs/day Round to 2,500 gallon total tank capacity. In addition, the last chamber of the second tank in series will be used as a dosing chamber. Therefore, the system will consist of two 1,500 gallon capacity tanks. Application for ISDS Permit 1 Derby Creek Company, Commercial SOILS INVESTIGATION On January 11, 1996, a soil profile pit was excavated by backhoe in the proposed area of the absorption system. The following soil profile was observed: from the ground surface to a depth of approximately 3 feet the soil consisted of a light brown silty sand, followed by river gravels with sand and cobbles to the extent of the excavation at a depth of 9 feet. Groundwater was encountered at a depth of 9 feet. Evidence of a seasonal high water table was not observed. On April 23, 1996, percolation tests were performed at the proposed absorption trench location. Three test holes were hand -dug to a depth of 2.5 feet. Soils encountered were consistant with the profile pit and consisted of a light brown silty sand. Neither groundwater nor evidence of a seasonal high water table were observed. The average percolation rate of the three holes was 5.4 minutes per inch (MPI). Soils having a percolation rate less than 5 MPI are not suitable for the disposal of wastewater. The percolation rate of one of the test holes was less than 5 MPI. On that date, groundwater in the soil profile pit, which was still open, had risen to 5.8 feet below ground surface (a depth from ground surface to groundwater of at least 6.5 feet is required). Alpine also measured relative elevations of the cabins and the absorption area and found that gravity feed to the two furthest cabins to the northeast would not be possible. For these reasons, a mound system has been designed. Infiltrators can be placed at the elevation of the existing ground surface following leveling and scarification to a depth of 3 inches. Soils used to cover infiltrators can be of variable composition, but should be able to support grass growth. TRENCH DESIGN A = Q/5 (T)0.5 A = (1,658 gpd/5) (10 mpi)o.s A = 1,048 SF Check with loading rate: For the type of soils found on site, the EPA Design Manual: Onsite Wastewater Treatment and Disposal Systems recommends a maximum application rate of 0.8 gallons per square foot per day. 1,658 od = 2,073 ft2 0.8 gal/ft2 This area will be used for design. with a 50% reduction for infiltrators = 1,036 SF Application for ISDS Permit 2 Derby Creek Company, Commercial Number of Infiltrator Units: 1.036 SF = 58 Infiltrator Units 18 SF/Infiltrator Length of Trenches: 58 infiltrator units x 6.25 ft./infiltrator unit = 2 trenches at 87.5 ft. long each 4 trenches and two trenches at 93.75 ft. MOUND SYSTEM The area proposed for the absorption lines is relatively flat a will require only minimal grading to provide a level surface on which to place infiltrators. The graded area should have an area to accomodate the square footage of the absorption trenches with an apron of 3-4 feet on all sides (see details). Infiltrators will be placed on the surface of the platform and native or non-native materials will be used to cover them to a depth of 1.0 - 1.5 feet. The mound will be appropriately revegetated. DOSING VOLUME Because the proposed area of the absorption trenches will be topographically higher than the septic tank inverts, pumps will be required to dose the infiltrators. 1.658 gpd = 332 gallons per dose 5 doses per day Size of the dosing chamber is 500 gallons, providing room for pumps and appurtanences. PUMP SYSTEM "' / r�6w-cam i, c. (�y G� U3 �-✓G % The second chamber of the second tank in series has a volume of approximately 666 gallons and should be sufficient to house the pumps and provide the dosing volume. A high float switch will trigger duplexing (alternation) of the two pumps and a low float switch will turn the pumps off at the end of the dosing cycle. A float switch placed above the high switch will cause both pumps to start (if one fails the other will pump) and trigger an alarm indicating failure of the pump. The alarm will be wired to a control panel located in one of the cabins or in the Battey Residence to alert the owners of the need for maintenance. The force main will be installed with a high point so that at the end of the pumping Icycle effluent in the line will gravity drain to the infiltrators or back into the dosing chamber (via a small hole in the line, located in the tank just above the pumps). Design of the pumps, electronics and appurtanences will be by others. APPLICABLE SETBACKS The proposed location of the septic tank and absorption trenches is outside of all applicable setback distances. The existing irrigation ditch on site will be re-routed to conform with Application for ISDS Permit 3 Derby Creek Company, Commercial setback requirements. The engineer will confirm setbacks during the inspection. Application for 1SDS Permit 4 Derby Creek Company, Commercial ISDS PERMIT: �'� b 2 s— DATE: � c\ Icke. V.,CreISDS FINAL OBSERVATION COMPLETENESS` FORM _Tank is %S'00 gal9A Tank Material: —CAST C aV CWJVe. V Tank is located 1 Z ft. and N \0 2.° degrees from Cab i IA U r vA2v' C %CC JN-*\W i,n> (permanent landmark) Tank is located ft. and degrees from % (permanent landmark) y Tank set level. �v - Tank lids within 8" of finished grade. _Size of field W S71 units 3 2. S lineal ft. / Technology Cleanout is installed in between tank and house (+ 1/100 ft) C^W'*- x* 3 There is a "T" that goes down 14 inches in the inlet and outlet of the tank. _Inlet and outlet is sealed with tar tape, rubber gasket, etc. o a V/ Tank has two compartments with the larger compartment closest to the house. y�^ C* bi M --A141 �Measure distance and relative direction to field. ZZ t N 1 ` � Sf _Depth of field \ ft. V Soil interface raked. C�br `Z? C,Oav�Ctn�i' _Inspection portals at the end of each trench. .1 Proper distance to setbacks. V Chambers properly installed per manufacturers specifications. (Chambers latched, end plates properly installed, rocks removed from trenches, etc.) Other: Inspection meets requirements. Copy form to installer's file if recommendations for improvement were suggested. ACTION TAKEN: Setbacks Well Potable Water Lines House Property Line Lake Stream Dry Gulch Tank Drain Field 100 25 20 10 50 25 10 10 Tank 50 10 5 10 50 10 * 10 0 �I. m m 0 D FA of Pon Sl M N i I 1562-96 Tax# 1685-222-00-002 JOB NAME 22543 Colorado River Y Burns, CO COMMERCIAL JOB NO. ZO-JOB LOCATION BILL TO DATE STARTED DATE COMPLETED DATE BILLED C GL'vTJ A F 7 JOB COST SUMMARY TOTAL SELLING PRICE TOTAL MATERIAL TOTAL LABOR INSURANCE SALES TAX MISC. COSTS TOTAL JOB COST GROSS PROFIT LESS OVERHEAD COSTS % OF SELLING PRICE NET PROFIT JOB FOLDER Product 278 Qp NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MA 01471 JOB ■ OL®ER Printed in U.S.A.