HomeMy WebLinkAbout671 Green Mountain Dr - 210904212006INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway • Eagle, Colorado 81631 P
pTelephone:328-8755 6 6 l
YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1467
Please call for final inspection before covering any portion of installed system.
RETAIN WITH RECEIPT RECORDS
APPLICANT / AGENT: OWNER:
PERMIT FEE PERCOLATION TEST FEE _ RECEIPT # CHECK #
(Site Plan MUST be attached)
ISDS Permit #
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY
P. O. BOX 179
EAGLE, CO 81631
328-8755/927-3823 (El Jebel)
**************************************************************************
* PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00
*
*
* MAKE 'ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER"
PROPERTY OWNER:
MAILING ADDRESS:
APPLICANT/CONTACT PERSON*,
MAILING ADDRESS:
LICENSED ISDS
COMPANY/DBA:
CONTRACTOR: Al— J,P '
Aii) f oWir ADDRESS:
PHONE: _fg;7r!)
PHONE: { )
PHONE: ( ) 50&
***************************************************************************
PERMIT APPLICATION IS FOR: (L'New Installation ( ) Alteration ( ) Repair
***************************************************************************
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Building Permit # f Z Z I (if known)
Legal Description: Subdivision:&' -AG L e AhLthiling•_Block: Lot No.
Tax Parcel Number: -�Q.� �—
Lot Size:
Street Address: dC 71 �/�'f✓ �" �j``
BUILDING PE: (Check applicable category)
( Residential/Single Family
( ) Residential/Mul_ti-Family*
( ) Commercial/Industrial*
TYPE OF WATER SUPPLY: (Check applicable category)
( ) Well ( ) Spring ( ) Surface
um aca
(vY Public Name of Supplier: 6 6 4C
Number
Number
Type _
of Bedrooms
of Bedrooms
*These systems,, require design by a Registered Professional Engineer
SIGNATURE: _ /C��/s'--�' Date:
TO BE COMPLETFIP BY THE COUNTY
AMOUNT PAID: Y / RECEIPT #: 41Yob DATE:
CHECK #: CASHIER(-
Community Development Department
(970)328-8730
Fax: (970) 328-7185
TDD: (970) 328-8797
EAGLE COUNTY, COLORADO
December 7, 1995
Phil and Cinydi Bain
P.O. Box 334
Minturn, CO 81645
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
RE: Final of ISDS Permit No. 1467-95 Parcel #2109-042-12-006.
Property location: 0671 Green Mountain Dr., Eagle, CO.
Dear Mr. and Mrs. Bain,
This letter is to inform you that the above referenced ISDS
Permit has been inspected and finalized. Enclosed is a copy to
retain for your records. This permit does not indicate
compliance with any other Eagle County requirements. Also
enclosed is a brochure regarding the care of your septic system.
Be aware that later changes to your building may require
appropriate alterations of your septic system.
If you have any questions regarding this permit, please contact
the Eagle County Environmental Health Division at 328-8755.
Sincerely,
Janet Kohl
Environmental Health Department
Eagle County Community Development
ENCL: Information Brochure
Final ISDS Permit
cc: files
COMMUNITY DEVELOPMENT
DEPARTMENT
(303) 328.8730
DATE:
TO:
FROM:
EAGLE COUNTY, COLORADO
June 5, 1995
K. W. Pipe Fixation
Environmental Health Division
725 CHAMBERS AVE.
P.O. BOX 179
EAGLE, COLORADO 81631
FAX (303) 328-7207
RE: Issuance of Individual Sewage Disposal System
Permit No. 1467, Tax Parcel #2109-042-12-006
Property Location: 0671 Green Mountain Dr.,
Eagle.
Enclosed is your ISDS Permit No. 1467-95 is valid for 120 days.
The enclosed copy of the permit must be posted at the
installation site. Any changes in plans or specifications
invalidates the permit unless otherwise approved. Please call
our office well in advance for the final inspection.
Systems designed by a Registered Professional Engineer must be
certified by the Engineer indicating that the system was
installed as specified. Eagle County does not perform final
inspections on engineer designed systems.
Permit specifications are minimum requirements only, and should
be brought to the property owner's attention.
This permit does not indicate conformance with other Eagle County
requirements.
If you have any questions, please feel free to contact the
Environmental Health Division at 328-8755.
cc: files
COMMUNITY DEVELOPMENT
DEPARTMENT
(303) 328 8730
EAGLE COUNTY, COLORADO
May 30, 1995
Luiza Petrovska
LKP Engineering, Inc.
P. O. Box 1452
Avon, CO 81620
Dear Ms. Petrovska,
725 CHAMBERS AVE.
P.O. BOX 179
EAGLE. COLORADO 81631
FAX (303) 328-7207
After talking with you earlier today, I discussed the individual
septic design that you submitted for the Bain residence, with Ray
Merry, the Environmental Health Division Manager. Eagle County
requires that you insure a four foot separation to bedrock, or
ground water. Your soil profile information was only to four
feet. Thus, we have no information on the soil conditions four
feet below the bottom of the leach field, and no assurance of the
required four foot separations.
Also, the use of distribution boxes are discouraged in Eagle
County, due to weather and geological conditions. We recommend
the use of serial distribution, unless there are conditions that
prohibit this. Serial distribution will allow the progressive
formation of a bio-mat in the trenches, as needed, and therefore
better effluent treatment. Please inform us of any conditions
that prohibit the use of serially distributing the effluent for
this system, or re -design the system so that it is serially
distributed.
The building permit, number 6978 will be on hold until these
matters are addressed. The ISDS file number for this property is
number 1467-95.
Sincerely,
Laura Fawcett
Environmental Health Specialist
LKP Engineering, Inc.
November 28, 1995
Phil and Cyndi Bain
P.O. Box 3422
Eagle, CO 81631
RE: Inspection of Septic System Installation
Lot 6, Eagle Hill Subdivision
Eagle County, Colorado
Project No. 9506
Dear Phil and Cyndi:
At the request of Phil, on November 25 and 26,
Lot 6, Eagle Hill Subdivision, Eagle County, Colorado.
inspect the septic system installation.
1995, we visited the construction site on
The purpose of our site visit was to
They installed the septic system in general compliance with the design recommendations,
as shown on the Septic System Design, Revised Drawing No. 9506SD, last dated June 2, 1995.
Eight feet east and two feet north from the northwest building corner there was a building sewer
cleanout. Northwest, from the northwest building corner, two more cleanouts were visible. One
of them was at the inlet and the other one at the outlet of th 00 ? allon two compartment
concrete septic tank. They excavated four trenches near the proposed leachfield. They filled the
trenches with clean, coarse sand, passing U.S. Standard Siev� The sand was wetted and
compacted. Four inch diameter perforated, PVC pipe was laid on top of the sand. They positioned
the perforations on the bottom of the pipe. Each trench had 50-foot segment of the perforated
pipe. The pipes were connected by serial distribution. Also, the perforated pipes in each trench
had a slight slope (from 0.4 to 1.0 percent) in the flow direction. Average horizontal distance
from pipe to pipe was about twelve feet. They installer two cleanouts in the leachfield. One was
on the north end of the western most trench, and the other one was on the middle of the solid
pipe connecting the north ends of the second and third trenches. Please follow the design
recommendations for backfilling. They should cover the entire leachfield with a minimum of 12
inches of topsoil and revegetate. If you have any questions, please do not hesitate to call.
Sincerely,
,
LKP Engineering, I� �•',;" ��
Luiza Petrovska P� i°• / 1'� �``'
President /�"�IA1MO
`;��i���`��
cc: Mr. Ray Merry, Eagle County Environmental Health Division
C:\OFFICE\NVPWrN\WPDOCS\9506INS.LET
P.O. Box 1452, Avon, Colorado 81620 • (970) 827-9088 Tel • (970) 827-9089 Fax
14b/-95 - Tax Parcel #2109-042-12-006
JOB NAM Lot 6, Eagle Hills Subdivision BAIN
0671 Green Mountain Dr., Eagle
JOB NO. B/0-6 _ 17'
JOB LOCATION
BILL TO
DATE STARTED
DATE COMPLETED
DATE BILLED
s`361
olT
Y \
21,
-
.� �C r ;�
�/ O � ,J I j
10 / /
. � G •. l •.. ^ vim''
7/ . � l� `� � ..S /' /�7
/1� , Or,
e7 % 9/— 0
zqr
/%P o11
sl c�26
�=
—Zee
JOB COST SUMMARY
TOTAL SELLING PRICE
'TOTAL MATERIAL
TOTAL LABOR
INSURANCE
SALES TAX
MISC. COSTS
TOTAL JOB COST
GROSS PROFIT
LESS OVERHEAD COSTS
% OF SELLING PRICE
NET PROFIT
JOB FOLDER Product 278 Q® NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MA 01471 JOS FOLDER Printed in U.S.A.