Loading...
HomeMy WebLinkAbout671 Green Mountain Dr - 210904212006INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, Colorado 81631 P pTelephone:328-8755 6 6 l YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1467 Please call for final inspection before covering any portion of installed system. RETAIN WITH RECEIPT RECORDS APPLICANT / AGENT: OWNER: PERMIT FEE PERCOLATION TEST FEE _ RECEIPT # CHECK # (Site Plan MUST be attached) ISDS Permit # APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. O. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (El Jebel) ************************************************************************** * PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 * * * MAKE 'ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" PROPERTY OWNER: MAILING ADDRESS: APPLICANT/CONTACT PERSON*, MAILING ADDRESS: LICENSED ISDS COMPANY/DBA: CONTRACTOR: Al— J,P ' Aii) f oWir ADDRESS: PHONE: _fg;7r!) PHONE: { ) PHONE: ( ) 50& *************************************************************************** PERMIT APPLICATION IS FOR: (L'New Installation ( ) Alteration ( ) Repair *************************************************************************** LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Building Permit # f Z Z I (if known) Legal Description: Subdivision:&' -AG L e AhLthiling•_Block: Lot No. Tax Parcel Number: -�Q.� �— Lot Size: Street Address: dC 71 �/�'f✓ �" �j`` BUILDING PE: (Check applicable category) ( Residential/Single Family ( ) Residential/Mul_ti-Family* ( ) Commercial/Industrial* TYPE OF WATER SUPPLY: (Check applicable category) ( ) Well ( ) Spring ( ) Surface um aca (vY Public Name of Supplier: 6 6 4C Number Number Type _ of Bedrooms of Bedrooms *These systems,, require design by a Registered Professional Engineer SIGNATURE: _ /C��/s'--�' Date: TO BE COMPLETFIP BY THE COUNTY AMOUNT PAID: Y / RECEIPT #: 41Yob DATE: CHECK #: CASHIER(- Community Development Department (970)328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 EAGLE COUNTY, COLORADO December 7, 1995 Phil and Cinydi Bain P.O. Box 334 Minturn, CO 81645 Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 RE: Final of ISDS Permit No. 1467-95 Parcel #2109-042-12-006. Property location: 0671 Green Mountain Dr., Eagle, CO. Dear Mr. and Mrs. Bain, This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at 328-8755. Sincerely, Janet Kohl Environmental Health Department Eagle County Community Development ENCL: Information Brochure Final ISDS Permit cc: files COMMUNITY DEVELOPMENT DEPARTMENT (303) 328.8730 DATE: TO: FROM: EAGLE COUNTY, COLORADO June 5, 1995 K. W. Pipe Fixation Environmental Health Division 725 CHAMBERS AVE. P.O. BOX 179 EAGLE, COLORADO 81631 FAX (303) 328-7207 RE: Issuance of Individual Sewage Disposal System Permit No. 1467, Tax Parcel #2109-042-12-006 Property Location: 0671 Green Mountain Dr., Eagle. Enclosed is your ISDS Permit No. 1467-95 is valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Please call our office well in advance for the final inspection. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County does not perform final inspections on engineer designed systems. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. If you have any questions, please feel free to contact the Environmental Health Division at 328-8755. cc: files COMMUNITY DEVELOPMENT DEPARTMENT (303) 328 8730 EAGLE COUNTY, COLORADO May 30, 1995 Luiza Petrovska LKP Engineering, Inc. P. O. Box 1452 Avon, CO 81620 Dear Ms. Petrovska, 725 CHAMBERS AVE. P.O. BOX 179 EAGLE. COLORADO 81631 FAX (303) 328-7207 After talking with you earlier today, I discussed the individual septic design that you submitted for the Bain residence, with Ray Merry, the Environmental Health Division Manager. Eagle County requires that you insure a four foot separation to bedrock, or ground water. Your soil profile information was only to four feet. Thus, we have no information on the soil conditions four feet below the bottom of the leach field, and no assurance of the required four foot separations. Also, the use of distribution boxes are discouraged in Eagle County, due to weather and geological conditions. We recommend the use of serial distribution, unless there are conditions that prohibit this. Serial distribution will allow the progressive formation of a bio-mat in the trenches, as needed, and therefore better effluent treatment. Please inform us of any conditions that prohibit the use of serially distributing the effluent for this system, or re -design the system so that it is serially distributed. The building permit, number 6978 will be on hold until these matters are addressed. The ISDS file number for this property is number 1467-95. Sincerely, Laura Fawcett Environmental Health Specialist LKP Engineering, Inc. November 28, 1995 Phil and Cyndi Bain P.O. Box 3422 Eagle, CO 81631 RE: Inspection of Septic System Installation Lot 6, Eagle Hill Subdivision Eagle County, Colorado Project No. 9506 Dear Phil and Cyndi: At the request of Phil, on November 25 and 26, Lot 6, Eagle Hill Subdivision, Eagle County, Colorado. inspect the septic system installation. 1995, we visited the construction site on The purpose of our site visit was to They installed the septic system in general compliance with the design recommendations, as shown on the Septic System Design, Revised Drawing No. 9506SD, last dated June 2, 1995. Eight feet east and two feet north from the northwest building corner there was a building sewer cleanout. Northwest, from the northwest building corner, two more cleanouts were visible. One of them was at the inlet and the other one at the outlet of th 00 ? allon two compartment concrete septic tank. They excavated four trenches near the proposed leachfield. They filled the trenches with clean, coarse sand, passing U.S. Standard Siev� The sand was wetted and compacted. Four inch diameter perforated, PVC pipe was laid on top of the sand. They positioned the perforations on the bottom of the pipe. Each trench had 50-foot segment of the perforated pipe. The pipes were connected by serial distribution. Also, the perforated pipes in each trench had a slight slope (from 0.4 to 1.0 percent) in the flow direction. Average horizontal distance from pipe to pipe was about twelve feet. They installer two cleanouts in the leachfield. One was on the north end of the western most trench, and the other one was on the middle of the solid pipe connecting the north ends of the second and third trenches. Please follow the design recommendations for backfilling. They should cover the entire leachfield with a minimum of 12 inches of topsoil and revegetate. If you have any questions, please do not hesitate to call. Sincerely, , LKP Engineering, I� �•',;" �� Luiza Petrovska P� i°• / 1'� �``' President /�"�IA1MO `;��i���`�� cc: Mr. Ray Merry, Eagle County Environmental Health Division C:\OFFICE\NVPWrN\WPDOCS\9506INS.LET P.O. Box 1452, Avon, Colorado 81620 • (970) 827-9088 Tel • (970) 827-9089 Fax 14b/-95 - Tax Parcel #2109-042-12-006 JOB NAM Lot 6, Eagle Hills Subdivision BAIN 0671 Green Mountain Dr., Eagle JOB NO. B/0-6 _ 17' JOB LOCATION BILL TO DATE STARTED DATE COMPLETED DATE BILLED s`361 olT Y \ 21, - .� �C r ;� �/ O � ,J I j 10 / / . � G •. l •.. ^ vim'' 7/ . � l� `� � ..S /' /�7 /1� , Or, e7 % 9/— 0 zqr /%P o11 sl c�26 �= —Zee JOB COST SUMMARY TOTAL SELLING PRICE 'TOTAL MATERIAL TOTAL LABOR INSURANCE SALES TAX MISC. COSTS TOTAL JOB COST GROSS PROFIT LESS OVERHEAD COSTS % OF SELLING PRICE NET PROFIT JOB FOLDER Product 278 Q® NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MA 01471 JOS FOLDER Printed in U.S.A.