134 Jouflas Ranch Rd - 194127403002
INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 2234-02 BP NO. 14542 OWNER: ERIC AND ANDI REINHARD PHONE: 303-713-4902 MAILING ADDRESS: 6975 S. POLO RIDGE DR., LITTLETON CO 80128 APPLICANT: STEVE SANDOVAL PHONE: 970-376-2631 SYSTEM LOCATION: 134 JOUFLAS RANCH RD., WOLCOTT, CO TAX PARCEL NO. 1941-274-03-002 LICENSED INSTALLER:_VANDERWALKER CONSTRUCTION. BOB VANDERWALKER LICENSE NO. 62-02 PHONE: 970-926-1465 DESIGN ENGINEER: LKP ENGINEERING, LUIZA PETROVSKA PHONE NO. 970-926-9088 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 5 BEDROOM RESIDENCE 1500 GALLON 3-COMPARTMENT SEPTIC TANK WITH A LIFT STATION IN THE 3RD COMPARTMENT, 1406 SQUARE FEET OF ABSORPTION AREA CREDIT, VIA 45 INFILTRATOR UNITS, AS PER ENGINEER'S DESIGN DATED 9/10/02 SPECIAL INSTRUCTIONS: INSTALL AS PER ENGINEER'S DESIGN WITH A CLEANOUT BETWEEN THE TANK AND THE HOUSE AND INSPECTION POR- TALS IN EACH TRENCH. PLEASE NOTE HIGHLIGHTED SECTION OF DESIGN THAT INDICATES THE PERFORATED PIPE IN THE FIRST TRENCH OF 15 INFILTRATOR UNITS ONLY. BE SURE TO MAINTAIN ALL APPLICABLE SET -BACK REQUIREMENTS, SPECIFICALLY: 110 FEET FROM THE LEACH FIELD TO THE WELL, AND 50 FEET FROM THE SEPTIC TANK TO THE WELL. WELL LOCATION MUST BE INDICATED ON THE AS -BUILT DRAWING FROM THE ENGINEER. RAKE ALL TRENCH SURFACES TO PREVENT THE SMEARING OF SOILS. AND DO NOT INSTALL IN WET WEATHER CALL EAGLE COUNTY ENVIRONMENTAL HEALTH AND THE DESIGN ENGINEER FOR THE FINAL INSPECTION PRIOR TO BACK FILLING ANY PART OF THE INSTALLATION, OR WITH ANY QUESTIONS REGARDING THE INSTALLATION. THE BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS BEEN INSPECTED AND APPROVED. ENVIRONMENTAL HEALTH APPROVAL: LAURA FAWCETT DATE: OCTOBER 3.2002 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 1406 SQUARE FEET (VIA 45 INFILTRATOR UNITS AS PER ENGINEER'S DESIGN) INSTALLED CONCRETE THREE COMPARTMENT SEPTIC TANK: 1500 GALLONS LOCATED 283 DEGREES AND 7 FEET FROM THE CLEANOUT ON THE WEST SIDE OF THE HOUSE. COMMENTS: THE FINAL INSPECTION WAS DONE BY LAURA FAWCETT OF EAGLE COUNTY ENVIRONMENTAL HEALTH AND THE DESIGN ENGIN- EER ON JUNE 24, 2003. THE ENGINEER'S FINAL CERTIFICATION AND AS -BUILT DRAWING WERE RECEIVED ON JULY 8, 2003. LETTER FROM CON- TRACTOR REGARDING THE PUMP AND ALARM INSTALLATION RECEIVED ON NOVEMBER 20, 2003. THIS SYSTEM IS LARGE ENOUGH TO ACCOM- MODATE A FIVE BEDROOM RESIDENCE. ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. ENVIRONMENTAL HEALTH APPROVAL )( 2�t� �� DATE: NOVEMBER 24, 2003 INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 2234-02 BP NO. 14542 OWNER: ERIC AND ANDI REINHARD PHONE: 303-713-4902 MAILING ADDRESS: 6975 S. POLO RIDGE DR., LITTLETON CO 80128 APPLICANT: STEVE SANDOVAL PHONE: 970-376-2631 SYSTEM LOCATION: 134 JOUFLAS RANCH RD., WOLCOTT, CO TAX PARCEL NO. 1941-274-03-002 LICENSED INSTALLER: VANDERWALKER CONSTRUCTION, BOB VANDERWALKER LICENSE NO. 62-02 PHONE: 970-926-1465 DESIGN ENGINEER: LKP ENGINEERING, LUIZA PETROVSKA PHONE NO. 970-926-9088 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 5 BEDROOM RESIDENCE 1500 GALLON 3-COMPARTMENT SEPTIC TANK WITH A LIFT STATION IN THE 3'-" COMPARTMENT, 1406 SQUARE FEET OF ABSORPTION AREA CREDIT, VIA 45 INFILTRATOR UNITS, AS PER ENGINEER'S DESIGN DATED 9/10/02 SPECIAL INSTRUCTIONS: INSTALL AS PER ENGINEER'S DESIGN, WITH A CLEAN -OUT BETWEEN THE TANK AND THE HOUSE AND INSPECTION PORT- ALS IN EACH TRENCH. PLEASE NOTE HIGHLIGHTED SECTION OF DESIGN THAT INDICATES THE PERFORATED PIPE IN THE FIRST TRENCH OF 15 IN- FILTRATOR UNITS ONLY. BE SURE TO MAINTAIN ALL APPLICABLE SET -BACK REQUIREMENTS, SPECIFICALLY: 110 FEET FROM THE LEACH FIELD TO THE WELL, AND 50 FEET FROM THE SEPTIC TANK TO THE WELL. WELL LOCATION MUST BE INDICATED ON THE AS -BUILT DRAWING FROM THE ENGINEER. RAKE ALL TRENCH SURFACES TO PREVENT THE SMEARING OF SOILS, AND DO NOT INSTALL IN WET WEATHER. CALL EAGLE COUN- TY ENVIRONMENTAL HEALTH AND THE DESIGN ENGINEER FOR THE FINAL INSPECTION PRIOR TO BACK FILLING ANY PART OF THE IN- STALLATION, OR WITH ANY QUESTIONS REGARDING THE INSTALLATION. THE BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS BEEN INSPECTED AND APPROVED. ENVIRONMENTAL HEALTH APPROVA %: DATE: OCTOBER 3, 2002 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: SQUARE FEET (VIA ) INSTALLED TANK: GALLONS IS LOCATED DEGREES AND FEET INCHES FROM COMMENTS: ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. ENVIRONMENTAL HEALTH APPROVAL DATE: in bomplete Applications Will NOT Be Accepted (Site.41an MUST be attached) ISDS Permit #3���-- Building Permit #5" APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. O. BOX 179 EAGLE, CO 81631 Eagle (970)328-8755, Fax (970)328-0349, El Jebel (970)927-3823 **************************************************************************** * FEE SCHEDULE * APPLICATION FEE $350.00 *_ THIS FEE INCLUDES THE ISDS PERMIT, SITE EVALUATION (PERCOLATION TEST, * SOIL PROFILE OBSERVATION) AND FINAL INSPECTION * ADDITIONAL FEES MAY BE CHARGED IF A REINSPECTION IS NECESSARY, OR A * PRE -CONSTRUCTION SITE VISIT OR CONSULTATION IS NEEDED * REINSPECTION FEE $47.00, PRE -CONSTRUCTION SITE VISIT FEE $85.00 * MAKE ALL..REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" **************************************************************************** PROPERTY OWNER: Eric & Andi Reinhard MAILING ADDRESS: 6975 S. Polo Ridge Dr.,Littleton,CO 80128 PHONE:303-713-4902 APPLICANT/CONTACT PERSON: StPvp Gandoval PHONE:970-376=26-11 _LICENSED SYSTEMS CONTRACTOR:Bnh Vanderwalker PHONE:970-926-1465 COMPANY/DBA: Vandprwalkp�r ronct,Tnr,ADDRESS: P.O. Box 3571, Vail,CO 81658 *************************************************************************** PERMIT APPLICATION IS FOR: (X) NEW INSTALLATION ( ) ALTERATION ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description: Lot 6, Filing 2, Travis Creek Suhrlivisinn Tax Parcel Number: 1941-274-03002 Lot Size: 10,009 Ac. Physical Address: 134 Jouflas/Ranch Rd.,Wolcott,CO 81655 BUILDING TYPE: (Check applicable category) (x) Residential/Single Family Number of Bedrooms. 5 ( ) Residential/Multi-Family* Number of Bedrooms ( ) Commercial/Industrial* Type *These systems require design by a Registered Professional Engineer TYPE OF WATER SUPPLY: (� Well ( ) ( Public. Narr APPLICANT SIGNA (Check applicable category) Spring ( ) Surface **************************** AMOUNT PAID: RECEIPT ##-: ����--� DATE: 9 ,io-4 CHECK # : "` CASHIER: DEPARTMENT OF ENVIRONMENTAL HEALTH (970) 328-8755 FAX (970) 328-8788 TDD: (970) 328-8797 TOLL FREE: 800-225-8136 www.eagle-county.com EAGLE COUNTY, COLORADO Date: October 3, 2002 TO: Vanderwalker Construction Raymond P. Merry, REHS Director FROM: Environmental Health Division RE: Issuance of Individual Sewage Disposal System Permit #2234-02. Tax Parcel #1941-274-03-002. Property Location: 134 Jouflas Ranch Rd., Wolcott, CO:, Reinhard residence. Enclosed is your ISDS Permit #2234-02, and afield copy of the engineer design stipulated on the' permit. It is valid for 120 days, or for the duration of your current building permit for this -property. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit:unless otherwise approved. Please note any special requirements that may have been .added to the design by this department. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County Environmental Health must also view the installation prior to back filling. Please call well in advance for your final inspection. Your TCO will not be issued until our office receives this certification from the engineer, and views the installation: Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. Please notify this office if you have not been contracted to perform this installation. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files LKP Engineering, Luiza Petrovska OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 DEPARTMENT OF ENVIRONMENTAL HEALTH (970)328-8755 FAX: (970) 328-8788 TOLL FREE:800-225-6136 www.eagle-county.com November 24, 2003 Eric and Andi Reinhard 6975 S. Polo Ridge Dr. Littleton, CO 80128 ETNQ COUNTY RAYMOND P. MERRY, REHS Director RE: Final of ISDS Permit #2234-02, Tax Parcel #1941-274-03-002. Property location: 134 Jouflas Ranch Rd., Wolcott, CO. Dear Mr. and Mrs. Reinhard: This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Janet Kohl Eagle County Environmental Health Department ENCL: Educational Brochure Final ISDS Permit cc: files, November 2003 Chrono file OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 5 L -P Engineering,, Inc, CIVIUGEOTECHNiCAL June, 24, 2003 Mr. Steve Sandoval Buildwo rks,11, ILLC P.O. Drawer 4299 Avon, CO 81620 Dear Steve: RE: Pump Elevations for ,Septic System Installation Lot 6, Travis Creek Subdivision Filing No. 2 0134 J'ouflas Ranch Road Wolcott, Eagle County, Colorado Project No, 02100 - ISDS Permit No. 2234-02 At the request of Bob Vanderwalker, on June 2-3, 2003, we visited the construction site on Lot 6, Travis Creek Subdivision Piling No. 2, 0134 Jouflas Raneh Road, Eagle County, Colorado. The purpose of our site visits was to provide on -site consultation for the site suitability for the leachfleld and the setbacks from the retaining wall. Also, Bob provided us with the horizontal and vertical distances from the pump tank to the invert of the leachfield_ Based on this information we have recalculated the pump requirements and have resized the pump. The new requirement for the pump systern is a pump capable to deliver 20 gpm at a total head of 27 feet. We selected a Zoeller High head "Waste -Mate" Pump Model 292 with a 3-inch NPT flange. We unde,rstaud that a duplex pump will be installed. If you have any questions, please do not hesitate to call. Sincerely, LKP Engineering, ZuizalPetrovska, 7.�i em Pl President ram,. lam cc: Ms. Laura Fawcett, Eagle County Envirownental Health Division, fax: 328-0349 Steve Sandoval, Buildworks, lI LLC, fax # 926-9012. Seth Bossung, TAB Associates, Inc., fax # 748-1471 Bob Vanderwalker, Vanderwalker Construction, fax.# 926-1463 C,Aw P 10.LKl'1Q2100osi-pUMp.wQd P.O_ Box 2837, Edwards, CO 81632, (970) 926-9098 Tel, (970) 926-9089 Fax PLA / T[a -4gkJ A 'WT gHTN_4_4HTgWq AM-1 l=,PQG 7 Q7�7 Q� 9, Mb ' C.M CM GA 7 1 b 7 l Q M �e � SECTFON. 2.30.050 ,U�rLlFJf 1/�l.�F6 r�fNCF i��� FMR45R 0800 Product information ! 1� �� Supersedes presented here rettects V p///rip /" /•T 0399 conditions at time of regard ing publication. ,di crrepalnolest or NAIJ< To: P.O. 8OX 16347 • LouisvUJa, KY 40256.0347 visit our web site: Inconslstenoies. SHIP TO; 3649 Cane Run Road - Louisvilfs, KY 40211-1961 http:/lwWw.zoe11er.com ($02) 776-2731 • f (8W) 926-PUMP • FAX (602) 774-3624 COMPARE THESE FEATURES Non -clogging vortex impeller design bronze class 84-",4. • Durable cast construction. Cast iron switch case, base, motor and pump housing. No sheet metal parts to rust or corrode. All cast iron class 25-30 26000# tensile strength. • Stainless steel screws, bolts, float rod, handle guard, arm and seal assembly. 20 foot UL listed 3-wlre neoprene cord and plug. Extra cords lengths available in 25-35-W length only. • 3-phase models available. (292,115V,1PH only) • Wtor 60 cycle, 3450 RPM, oil filled, hermetically sealed, automatic reset thermal overload protected (1 PH only). • Maximum temperature for sewage or dewatering 130° F (54° C),120° F (49' C) for WD295. If over 130e F. consult factory. • Shaft Seal- Stainless steel carbon& ceramic rotary, • Corrosion resistant powder coated epoxy finish. Upper sleeve bearing and lower bell bearing running in bath of oil - Square Ring & Gasket - Neoprene. • All models pass 2" sollds (sphere). • Major width 12 Tle",, Height 18'lie'. (Single seal pumps) Automatic units available with floatoperated, submersible (NI=MA 6) 2-pole mechanical switch. On point 14 W - Off point 5". • Specify 2" or 3" NPT female flanged vertical discharge. • 10010 oomputerized testing. MODELS 4292-4293.4294.4295 DOUBLE SEAL PUMPS (nonauto only) • Protects motor from seal leaks. • Improved bearing lubrication. • Helps eliminate seal and bearing damage from dry runs. i Major width 12 %". Height 20 r1,6", Mats: The sizing of effluent systems normally requires variable Leval float(s) controls and properly sized basins to achieve required pumping cycles. 292 - 293 - 294 - 295 Singgle Seal .Series 4292 - 4293 - 4294 - 4295 Double Seal Series (for Pump Prefix ldentsitcadorr see News & Views 0052) CID* HIGH HEAD a "WA T&MATEii 1'M POWDER SUBMERSIBLE COATED, ;i VOUGH SEWAGE w�r�aa.Aaarr. ti.OR DEWATERING PUMP, `� 'See bp* Me For UL & C3A UUnpa 0 Copyright 2000 Zoeller Co. All rights reserved. 01a 17M aeltlrr -Lt lT gMTN-4-4MTgMq AM7 F.ARC Ig7F.G11 F. Celt+ :RQ PRER7. /b7. IgP �� t r■il"!1■■�■■■■ r■■■■�.® „�■■■■■ - ■■■■r Men=�1.,, ��. �i �■■■i�'ll�■`fir ■■�ir■r■r■■ �rr■�■�.�i�■�►�►r■fir■■ ENOS no moom ME „. ■■�i■■■■■E■■■■r■■■ii __ au ,cam z1u no 1m -so m 61a -,A ado ,® rm PER u,Nvyc CAUT70N Made) 293 should not be subj#*d to less than 15 fact. TDR. Standard all models - 2a ft. cord - % H L 292MODEIS 42112MObro, control Selection I.astlnpa 8inglessal 0pg64es"I Yolks - Ph Mode Amps Simplex Duplex CSA UL M282 - 115 1 Auto 15.0 1 or 1& 9 I Y Y N292 N429Z 115 .1 Nat 15.0 Z & 8 3 4r 5 & 5 Y Yg Standard all models - 20 iL cord . 1 H p_ ffiFU-DE-L6 Slnpleiieal 4295 Doo11186; 1 Garrhrd Selgdon V01% - Ph Mode Amps SlMPM Duplex Lietlns�s CSA UL 0293 -- 230 # Auld 14,2 1 or 1 & 9 Y y ma E4293 2$0 1 Nan Auto 102 12.0 2 cr 2$ 6 # Ur 1 & 9 3 or 5& k Yn1 Y y N " H293 Z00 Z06 1 14293 200,208 1 Nan 12.0 2 & 8 3 or 5 & 6 Y N ' F293 ` F4a 230 7.6 Z&4 3 & 4 or S & 6 Y Y " J293 " J4293 200-M 8.2 2& 4 3& 4 or 5 9 6 Y Y ` G293 " 44293 430 E3ft 4.0 2&4 3& 4or5AV03 - $75 3.3 2&4 3&9cr5&6 N N Standard all fflM.1s . 2n ft enrol. 41. u a 211,1900 4294MODELS Control Selection LI 91ngleSeal Doubleseat volts - Ph Mode Amps simplex Duplex CSA UL D294 230 1 Auto 13.7 1 cr 1 go y yrn 5294 E42U 230 1 Nan 1317 2 or 2 & 8 3 --or jN -VD-) " F04 2DO-208 1 At to 16.5 1 or # & 9 N N ' 1294 ' 14294 2DO- 1 Nan i6,s 2 & 7 3 or5 & a N N " 17294 ' F4 31 Non 9.5 1 9kA 1 3A4or5&6 V Y ` J294 ' J4294 200-208 9 1 Non 10.8 2& 4 3 8 4 or5 & 6 Y Y ` G� " G4294 460 31 Non 4,3 U4 3 & 4 or 5 & 6 Y Y " 8A294 575 3 Nan 3.8 2& 4 $& 4 or S& 6 Y N r lu 'v DOLlble Seal DesiiJn Weight 93-9G Il7g, 1I2 NPY Pr SK1a1s SELECTION GUIDE 1. Integral float operated mechanical switch, no external control requin5d. 2. Single piggyback wide angle variable level that swltch or double piggyback variable level float switch. Refer to FM0477. I Mechanical alternator "M-Pak" 10.0072 or 10.0075, 4. Simplex control panel. Refer to FMt228. b. See FM0712, for correct model of Electdcal Alternator. 6. Varlable level control Witch IM225 used as a control activator, with electrical altarnator duplex (3) or (4) float 'syslern. Standard 90 models - 20 fL card, 2 H.P. 7, SIMPLEX CONTROL Box 1t1-u,050, 115123ov 1 Ph max. 295MOr eL$ 4295MODELF, I control selection Listings "'SOW Double8eal Vohs - Ph Made AUW Non Amps 17.1 i7.1 simplex 1 cr 199 2 & 7 Duplei 3 or5 & 6 CSA N YW UL Y Y DQ95 W 2 1 lAS E4295 23f1 1 VVD295 - 230 1 Auto 17A N N ' HM - 100.208 1 Auto 205 10 r 1 & $ N N " 1205 " K295 200-208 1 Nm 20S 2 & 7a3&4i. N N ' F295 ' RM 23D 3 Non 12-7 2 & 4Y` Y ' J295 `J4296 ffiDa 3 Nm 14.3 2&4Y Y ' G285 ' G420 46D 3 Non 8.1 2&4Y Y ' 9A295 - W5 3 Non 4.9 2 & 4Y N 2 HP uses; one (1) utn91e piggyback wide angle variable level float switch or two (2) 10.0225 control switches for level control. 8. 4-hole "J-Box", }unction box, for wateltight canAeodon or wlred4n simplex or duplex operation. 9. 2-hale "J-Box",Junction box, for Watertight connection or splice. d t:AUT1oN All Installation of controls, protection devlceg #lid wiring should be done by a qualified licensed alectriclan_ A9 electrical and safety codes should be followed including the mosttecent National Electric Coda (NEC) end the klscupafianalSafety and Health Act (OSHA). Forinfonnat on onaddltkmalZtreilerproducW retertdcaaAogan$Imp(exwnhds, ' No Molded PIuQ FM1596; PI ark Va[Wk Level Svelte ft FMD477; I: K&Ical Alternator, I>t ilL Wod 4n1 avatable whit 20 Amp pmg. FMO486; Mechanical Alternator, f'1MN%; SurrAewags Basins, FM04$7; and CSAAPvmlwhautp14 a;sp. Simplex Control Box, FMO732; Rag SYM MS, W0787; and Junction Boxes, FM1597. RESERVE POWERED DESIGN For unusual conditions a reserve safety factor is engineered Into the design of every Zoeller pump. 0 Copyright 2000 Zoder Co. All rights reserved. 60/60 39Vd ONI 3NI833NIJN3 JA-1 66069ZGOLG 6v;6fl 2R2z/b7/qR ma x- Engineering, Ine. C[VIUGEOTECHNICAL July 3, 2003 Mr. Steve Sandoval 1iDuildworks 11, LLC P.O. Dxawer 4299 Avon, CO 81620 Dear Steve: RE; inspection of Septic System Installation Lot 6, Travis Creek Subdivision Filing No. 2 0134 J'ouflas Ranch Road Wolcott, Eagle County, Colorado Project No. 02100 - ISDS Permit No. 2234-02 At the request of Rob Vanderwalker, on June 24 and 27, 2003, we visited the construction site on Lot 6, Travis Creek Subdivision Filing No. 2, 0134 Jtouflas Ranch Road, Eagle County, Colorado. The purpose of our site visits was to observe the installation of the septic system. They installed the system in overall compliance with the septic system design, Drawing No. 02100SD_DWO, dated Soptct'nber 10, 2002. Cleanout was installed between the house and the septic tank, as shown on the sketch. They installed a 1500-gallon, three compartments, precast, concrete, septic tank. In the last compartment of the septic tank, they will install a duplex pump. There were three access openings on the tank. Risers will be installed over each of the openings to bring the covers within fl- inches of the finish grade_ We, recommended that a cone -shaped riser be installed over the pump chamber, for ease of maintenance. The effluent line from the pump tank to the first infiltrator of the top trench was a total distance of 176 feet. The effluent nine was 3-inch diameter sch40 PVC. Cruder the driveway the effluent line was double encased with a six-inch diameter, sch 40 pvc pipe. Forty-five, Standard Irxflltrator Chambers were installed in three trenches, as shown on the attached sketch_ Tracy trench had fifteen infiltrators. The infiltrators were connected with serial distribution. In the first and last infiltrator of each trench, inspection ports were installed. Horizontal distannee from center to center of the trenches, was 9 feet or more, The depth of the trenches was no more than 36 niches, Y e floats function and the alarms will be installed and tested at a later date and a korer will be submitted to us and to the Eagle County Anvii,-onmental Health Department. If you have any questions, please do not hesitate to call. Sincerely, LKP Engineering,tat Luiza Petrovska, P �'" •a f President 0 A ¢* Enclosure cc: Ms. Laura Fawcett, Eagle County Environmental Health Division, fax: 328-0349 Steve Sandoval, Buildworks, II LLC, fax # 926-9012 Seth Bossung, TAB Associates, Inc., fax # 748-1471 Bob Vanderwalker, Vanderwalker Construction, fax## 926-1463 C AWP 10-LKP\02 100os i-pump2. wpd P.O. Box 2837, Edwards, CO 81632, (970) 926-9088 Tcl, (970) 926-9089 Pax ZQ 39Vd ONI 9NId33NI!DN3 dA-1 66069Z6OL6 VV:Ot E00Z/8Vzo F L ;j Engineering, Inc. Fs BUILCIVILIOZOTECHMCALK -TC LOT 8, TRAMS CREEIt FILING NO, 2 0134 JOLIFLAS RANCH ROAD FAG'LF COUNTY, COLORADO a.i[.7[xlil � Uh1611 �� E j P.O. Box 2837, Edwards, CO 81632, (970) 9264088 Tel, (970) 926-9089.Fax Z8 39Vd ONI ONI633NION3 dA-1 68869ZGOL6 VV a8T COOZIBBIL0 ISDS PERMIT # PERCOLATION TEST &n'�,f2rSYER:SICAL, EAGLE COUNTY ENVIRONMENTAL HEATER �, ADDRESS: LEGALDESCRIPTION: ION: MAILING ADDRESS: TYPE OF DWELLING: NUMBER OF BEDROOMS: `� 7 TEST HOLES PRE-SOAKED: YES NO SOIL TIME WATER DEPTH INCHES OF FALL RATE PROFILE n� mmmom mmmmmmmmm -d mmmmmmmmm mmmmmmmmm ommmmmmmmm TIME TO DROP LAST INCH: PERC RATE: MINIMUM LEACH FIELD SIZE: MINIMUM SEPTIC TANK SIZE: COMMENTS: ENVIRONMENTAL HEALTH SPECIALIST K/ I LO DATE ISDS Permit * �34 _0 7_ Date ISDS Final Inspect on CQW16teness Form ✓- Tank is L RED gal. Tank Material Tank is located Lft. and6 degrees from � . �1 00 �-Tank is located LL ft. and degrees from {P6ZMM t l.na..skl u Tank set level. Tank lids within 8" of finished grade. ^^ . _ Size of fiel f ' units lineal ft.. i �_Cleanout is installed in between tank and house(+ 1/10Oft). V There is a "T" that goes down 14 inches in t and outlet of the tank. V/ Inlet.and outlet is sealed with tar -,tape, rubber gasket etc. T -has two -:compartments with the.:-1:arger,.-,QQmpartment closest to the ; .;L house . -7 f ! �D Mdcatinme: distance and relative dirept o - to ., .�A.elci Depth of field. ft. Z `l 15- ✓ Soil interface raked. Inspection portals at the.end of each trench.. i� Proper distance to setbacks. Chambers properly installed as per manufacturer$ specifications. (Chambers latched, end plates properly installed, rocks 'removed from trenches, etc.) Type of pipe used four building sewer Line Lb -LIv leach field Other 11. x C. Inspection meets rsauirements. Copy form to installer's file if recommendations for improvement very suggested. ACTION TAKEN: 2 )b Setbacks well Pot le House Property &ke Dry Tank Drain wa7Lines line -Stream Gulch Fie d 100 5 20 10 50 25 10 10 50 0 5 10 50 10 * 10 EAGLE- : REAUTx P.O. BOX 179 EAGLE, CO 81631 CALCULATED BY, CHECKED BY. DATE DATE rmuuue: 1 mo- i imp meeml o— Naeaeul U. ms.. wvwn, macs. vi•i �. iv wuar rnunc �u.e mcc �-ovvaavvaov Phone/Fax P. U. Drawer 4299 (970) 926-9012 Avon, CO 81620 ButidWorks 113, Inc. GENERAL CONIRACMG November 20, 2003 Eagle County Environmental Health Attn: Janet P.O_ Drawer 179 Eagle, CO 81631 Via Fax (970) 328-8788 Re: 134 .louflas Ranch Road, Wolcott, CO 81655 ISDS Permit #2234/Bldg Permit #14542 To Whom it May Concern: Please allow this letter to serve as verification of dual pump install, alarm install, and subsequent testing of said installation verifying successful operation of septic system. System has now been operating for over two weeks. If you have any further questions, please call me at 970-376-263. Thank you for releasing our permit for Certificate of Occupancy inspection. Id Wd£S:£0 200E OE 'nON ZT06 9E6 OL6 : 'ON XUA I I sAdomaii is : woNA LKP ENGINEERING, INC. P.O. Box 2837 Edwards, CO 81632-2837 (970) 926-9088 Fax (970) 926-9089 PERCOLATION TEST RESULTS Client: Eric Reinhard Location: Lot 6, Travis Creek 6975 S Polo Drive 0134 Jouflas Ranch Road Littleton, CO 80928- Eagle County, Colorado Project No.: 02100 P-1 P-2 P-3 TIME/DEPTH 29" 28" 29-8/16" 10 9-8/16" 8" lift 10 17-4/16" 7-12/16" 19-8/16" 11-8/16" 20" 9" 10 204/16" 3" 21-8/16" 2" 23" 3" 10 22-4/16" 2" 22-8/16" 1" 24" 1" 10 24-4/16" 2" 23-8/16" 1" 25" 1" 10 26-4/16" 2" 24-8/16" 1" 26" 1" 10 284/16" 2" 25-8/16" 1" 27" 1 PERC RATE 5 MIN/INCH 10 MINANCH 10 MINANCH AVG PERC g MPI Average Percolation Hole Diameter: 12" Holes Dug and Presoaked: August 14, 2002 Test Run: August 15, 2002 Soil Profile No. 2 By: Kiril Petrovski 0-3.5'- Topsoil 3.5-7'- Light to reddish brown sandy clay with angular sandstone rocks. No ground water encountered Soil Profile 0-3'- Topsoil No 1: 3-7'- Light brown, clayey sand with angular sandstone rocks, cobble and boulder size No ground water encountered LKP ENGINEERING, INC. P.O. Box 2837 Edwards, CO 81632-2837 (970) 926-9088 Fax (970) 926-9089 PERCOLATION TEST RESULTS Client: Eric Reinhard Location: Lot 6, Travis Creek 6975 S Polo Drive 0134 Jouflas Ranch Road Littleton, CO 80928 Eagle County, Colorado Project No.: 02100 P-1 P-2 P-3 TIME/DEPTH 2911 28" 29-8/16" 10 9-8/16" 8" 11" 10 17-4/16" 7-12/16" 19-8/16" 11-8/16" 20" 9" 10 204/16" 3" 21-8/16" 2" 23" 31' 10 22-4/16" 2" 22-8/16" 1" 24" 1" 10 24-4/16" 2" 23-8/16" 1" 25" lit 10 26-4/16" 2" 24-8/16" 1" 26" 1" 10 284/16" 2" 25-8/16" 1" 27" 111 PERC RATE 5 MINANCH 10 MIN/INCH 10 MIN/INCH AVG PERC 8 MPI Average Percolation Hole Diameter: 12" Holes Dug and Presoaked: August 14, 2002 Test Run: August 15, 2002 Soil Profile No. 2: 0-3.5'- Topsoil 3.5-7- Light to reddish brown sandy clay with angular sandstone rocks. No ground water encountered By: Kiril Petrovski Soil Profile 0-3'- Topsoil No 1: 3-7'- Light brown, clayey sand with angular sandstone rocks, cobble and boulder size No ground water encountered Q!/.4L/TY/7L/MP3�NCE ����SECTION:2.30.040 FM0494 co,M.9 i' 0300 Product information ~ UL / re, Supersedes presented here reflects )17ZI ) L O. 1097 conditions at time of publication. Consult factory regarding discrepancies or MAIL TO., P.O. BOX 16347 • Louisville; KY 40256-0347 visit our web site: inconsistencies. SHIP To: 3649 Cane Run Road • Louisville, KY 40211-1961 http://www.zoeller.com (502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624 COMPARE THESE FEATURES Non -clogging vortex impeller • Durable cast construction. Cast iron switch case, motor and pump housing, base and impeller. No sheet metal parts to rust or corrode. All cast iron class 25-30 25000# tensile strength. • Stainless steel screws, bolts, float rod, handle, guard and arm and seal assembly. • Shaft Seal - Carbon & ceramic rotary face seal, with stainless steal wetted parts. • UL-listed 3-wire neoprene cord and plug. 10 ft. standard for automatic. 15 ft. standard for nonautomatic. • Upper sleeve bearing and lower ball bearing running in a bath of oil. • Maximum temperature for sewage or dewatering 130°F. - 54°C. • Motor - 60 cycle, 1750 RPM, oil -filled, hermeti- cally sealed, automatic reset thermal overload protected (1 PH and Auto 3 PH). • All models are available in 2" or 3" discharge. • All models pass 2-inch solids (sphere). • Automatic units available with float operated, submersible (NEMA 6) mechanical switch. Available in both 1 and 3 Phase Units." • Corrosion resistant powder coated epoxy finish. • On point 151/4", Off point 51/4". • Major width 13 9/1e". Major height 1813/16". (Single seal pumps) MODELS 4282-4284 DOUBLE SEAL PUMPS (non -auto only) • Protects motor from seal leaks. • Improved bearing lubrication. • Helps eliminate seal and bearing damage from dry runs. • Major width 13 s/,e". Height 20 11/16". 282 - 284 Single Seal Series ,�;*•: 4282 - 4284 Double Seal Series `•�• LISTED s �� (For Pump Prefix Identification see News & Views 0052) * "WASTE -MATE" C10 SSPMA SUBMERSIBLE MES-u MBER AM SEWArE SEWAGE PUMP A"S.ASSN. OR DEWATERING PUMP 2" OR 3" FLANGED DISCHARGE • PASSES 2" SOLIDS AUTOMATIC THREE PHASE PUMP" POWDER COATED TOUGH' MODELSAVAILABLE DOUBLE SEAL PUMP -Automatic or Nonautomatic with single seal • Single phase or three phase motors avilable. -Nonautomatic with double seals • See selection chart for specifications or • 2" or 3" discharge. specific models. y� w approvariorzuu-zuovtrnorExtraDuty(ED)pumpsorpoubleSealSeries. See back page for UL & CSA Listings "THREE PHASE AUTOMATIC UNITS AVAILABLE IN 230V SINGLE SEAL ONLY. © Copyright 2000 Zoeller Co. All rights reserved. of w w 2 w w � 35 10 30 0 a w = 8 25 � z g 20 r 0 15 O 4 284/4284 '- 10 HEAD CAPACITY CURVE 282/4282-284/4284 MODEL FT. M. 5 1.52 10 3.05 15 4.57 20 6.10 25 7.62 30 9.14 LOCK VALVE: 82 4282 284 428 GAL. LTRS. GAL. LTRS. 130 492 180 681 95 360 158 598 63 238 135 511 33 125 106 401 5 19 76 288 43 163 26' 35' 2+5 I I 282/41 N��' �� 0 GALLONS 20I 40j60I 80�10j120I 140I 160I 1801200I LITERS 0 80 160 240 320 400 480 560 640 720 8 0 FLOW PER MINUTE 009927 CONSULT FACTORY FOR SPECIAL APPLICATIONS • Three phase pumps are available in 200/208V, 230V, or 460V, automatic and non- automatic*''. • Electrical alternators, for duplex systems, are available and supplied with an alarm. • Mechanical alternators, for duplex systems, are available with orwithoutalarm switches. • Combination starters are available • Variable level control switches are available for controlling single and three phase systems. • Double piggyback variable level float switches are available for variable level long cycle controls. • Long cords are available in lengths or 25 - 35 - 50 feet. • Simplex and duplex basins are available. SPECIFICATIONS CONTROL SELECTION Listings Single Seal Model Double Seal Model Volt -Phase Mode Amps HP CDrd Lgth. Simplex Duplex UL CSA M282 115 1Ph Automatic 10.3 112 10 1 - Y Y N282 N4282 115 1Ph Nonauto 10.3 112 15 2 3 or 5 & 6 Y Y D282 230 1Ph Automatic 5.0 112 10 1 - y Y E282 E4282 230 1Ph Nonauto 5.0 112 15 2 3 or 5 & 6 y Y^) 'H282 200-208 1Ph Automatic 6.1 1/2 10 1 - N N '1282 '14282 200-208 1Ph Nonauto 6.1 112 15 2 3 or 5 & 6 N N 'J282 'J4282 200-208 3Ph Nonauto 3.6 1/2 15 4 & 6 3&4 or 5&6 Y Y 'F282 'F4282 230 3Ph Nonauto 3.0 112 15 4 & 6 3&4 or 5&6 Y Y 'CF282 230 3Ph Automatic 3.0 112 15 1 - Y Y 'G282 'G4282 460 3Ph Nonauto 1.7 1/2 15 4 & 6 3&4 or 5&6 Y Y D284 230 1Ph Automatic 8.9 1 10 1 - Y Y E284 E4284 23 11Ph Nonauto 8.9 1 15 2 3 or 5 & 6 Y yr'1 'H284 2001208 1Ph Automatic 9.3 1 10 1 - N N '1284 '14284 200/208 1Ph Nonauto 9.3 1 15 2 3 or 5 & 6 N N 'J284 •J4284 2001208 3Ph Nonauto 5.5 1 15 4 & 6 3&4 or 5&6 Y N 'F284 'F4284 230 3Ph Nonauto 5.0 1 15 4 & 6 3&4 or 5&6 Y Y 'CF284 230 3Ph Automatic 5.0 1 15 1 - Y Y 'G284 'G4284 460 3Ph Nonauto 2.6 1 15 4 & 6 3&4 or 5&6 Y Y 5 -i 2' - 11 1/2 NPT 3" -8NPT 18 73/t6 I'I 6 1/4 SK1023 5 1 8 16 6 5/t6 j- - 4 5 `---� 2" - 11 1/2 NPT 8 NPT 20 11/16 6 1/4 SK1414 SELECTION GUIDE 1. Integral float operated 2-pole mechanical switch, no external control required. 2. Single piggyback variable level float switch or double piggyback variable level float switch. Refer to FM0477. 3. Mechanical altemator M-Pak 10-0072 or 10-0075. Refer to FMO495 4. Simplex three phase control panel. Refer to FM1228. 5. See FM0712 for correct model of Electrical Altemator. 6. Variable level control switch 10-0225 used as control activator, specify simplex (3) float or duplex (3) or (4) float system. ' No Molded Plug t9 GSA Approval without plug. Three phase automatic available in 230V only. A CAUTION For information on additional Zoeller products refer to catalog on Piggyback Variable Level Float Switches, All installation of controls, protection devices and wiring should be done by a qualified licensed FM0477; Electrical Alternator, FM0486; Mechanical Alternator, FM0495; Sump/Sewage Basins, FM0487; electrician. All electrical and safety codes should be followed including the most recent National Simplex Pump Control, FM1596; Alarm Systems, FM0732; and Disconnect/Rail Systems, FM0787. Electric Code (NEC) and the Occupational Safety and Health Act (OSHA). RESERVE POWERED DESIGN For unusual conditions a reserve safety factor is engineered into the design of every Zoeller pump © Copyright 2000Zoeller Co. All rights reserved. �Q21rX17-Y PUMP6 31NCE co,Mpgy� Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. SECTION: 2.30.040 FM0494 0300 ZQ Supersedes lip 1097 MAIL TO: P.O. BOX 16347 r Louisville, KY 40256-0347 visit our web site: SHIP TO: 3649 Cane Run Road •'Louisville, KY 40211-1961 httpJ/www.zoeller.com (502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624 COMPARE THESE FEATURES • Non -clogging vortex impeller. • Durable cast construction. Cast iron switch case, motor and pump housing, base and impeller. No sheet metal parts to rust or corrode. All cast iron class 25-30 25000# tensile strength. • Stainless steel screws, bolts, float rod, handle, guard and arm and seal assembly. • Shaft Seal - Carbon. & ceramic rotary face seal, with stainless steal wetted parts. • UL-listed 3-wire neoprene cord and plug. 10 ft. standard for automatic. 15 ft. standard for nonautomatic. • Upper6leeve. bearing and lower ball bearing running in p bath of oil. • Maximum temperature for sewage or dewatering 1 WT. - 54°C. • Motor - 60 cycle, 1750 RPM, oil -filled, hermeti- cally sealed, automatic reset thermal overload protected (1 PH and Auto 3 PH). • All models are available in 2" or 3" discharge. • All models pass 2-inch solids (sphere). • Automatic units available with float operated, submersible (NEMA 6) mechanical switch. Available in both 1 and 3 Phase Units.** • Corrosion resistant powder coated epoxy finish. • On point 151/4', Off point 51/4". • Major width 13 9/16". Major height 18 13/16". (Single seal pumps) MODELS 4282-4284 DOUBLE SEAL PUMPS (non -auto only • Protects motor from seal leaks. • Improved bearing lubrication. • Helps eliminate seal and bearing damage from dry runs. • Major width 13 g/16". Height 2011/16". 82 - 2 `84 Single Seal Series Q 2 _ Seal Series �m• 4282 4284 Double pCRA� LISTED (For Pump Prefix Identification see News & Views 0052) "WASTE -MATE" SSPMA * �SU7-,7 CIDSUBMERSIBLE AND SMAGE SEWAGE PUMP MFRS. ASSN. OR DEWATERING PUMP 2" OR 3" FLANGED DISCHARGE • PASSES 2" SOLIDS •Automatic orNonautomatic with single seal • Single phase or three phase motors avilable. •Nonautomatic with double seals • See selection chart for specifications or • 2" or 3" discharge. specific models. 'NOTE: NoULlisting orCSAapproval for 200-208V1i rhortxrrauurytcu)pulllva -••-- See back page for UL & CSA Listings -THREE PHASE AUTOMATIC UNITS AVAILABLE IN 230V SINGLE SEAL ONLY. U Copyright 2000 Zoeller Co. All rights reserved. 4 `r W w HEAD CAPACITY CURVE MODEL 282/4282 284 4284 FT. M. GAL. LTRS. GAL. LTRS. w � 282/4282-284/4284 5 1.52 130 492 180 681 :2 35 10 3.05 95 360 158 598 10 15 4.57 63 238 135 511 30 20 6.10 33 125 106 401 w = 8 25 25 7.62 5 ' 19 76 288 30 9.14 43 163 U LOCK VALVE: 26' 35' z 6 20 15 a 0 4-- E ��S. 284/4284 ~ 10--- - 2 282/4282 5 0 GALLONS 20I 40I 60I 80IGALLONS 1001121011401160118012000 LITERS 0 80 160 240 320 400 480 560 640 720 800 FLOW PER MINUTE 009927 CONSULT FACTORY FOR SPECIAL APPLICATIONS • Three phase pumps are available in 200/208V, 230V, or 460V, automatic and non- automatic*. • Electrical alternators, for duplex systems, are available and supplied with an alarm. • Mechanical alternators, for duplex systems, are available with or without alarm switches. • Combination starters are available • Variable level control switches are available for controlling single and three phase systems. • Double piggyback variable level float switches are available for variable level long cycle controls. • Long cords are available in lengths or 25 - 35 - 50 feet. • Simplex and duplex basins are available. SPECIFICATIONS CONTROL SELECTION Listings Single Seal Model Double Seal I Model Volt -Phase Mode Amps HP I Cord Lgth. Simplex Duplex UL CSA M282 115 1Ph Automatic 10.3 112 10 1 - Y Y N282 N4282 115 1Ph Nonauto 10.3 112 15 2 3 or 5 & 6 Y Y D282 230 1Ph Automatic 5.0 112 10 1 - Y Y E282 E4282 230 1Ph Nonauto 5.0 112 15 2 3 or 5 & 6 Y yo) `H282 200-208 1Ph Automatic 6.1 112 10 1 - N N `1282 •14282 200-208 1Ph Nonauto 6.1 112 15 2 3 or 5 & 6 N N •J282 `J4282 200-208 3Ph Nonauto 3.6 112 15 4 & 6 3&4 or 5&6 Y Y `F282 `F4282 230 3Ph Nonauto 3.0 112 15 4 & 6 3&4 or 5&6 Y Y `CF282 230 3Ph Automatic 3.0 112 15 1 - Y Y •G282 `G4282 460 3Ph Nonauto 1.7 112 15 4 & 6 3&4 or 5&6 Y Y D284 230 IN Automatic 8.9 1 10 1 - Y Y E284 E4284 230 1Ph Nonauto 8.9 1 15 2 3 or 5 & 6 Y Yo1 `H284 2001208 1Ph Automatic 9.3 1 10 1 - N N `1284 `I4284 2001208 1Ph Nonauto 9.3 1 15 2 3 or 596 N N `J284 `J4284 200/208 3Ph Nonauto 5.5 1 15 4 & 6 3&4 or 5&6 Y N `F284 `F4284 230 3Ph Nonauto 5.0 1 15 4 & 6 Y Y `CF284 230 3Ph Automatic 5.0 1 15 1 M Y Y `G284 'G4284 460 3Ph Nonauto 2.6 1 15 4&6 Y Y It --r 8 9/16 single seal Design Weight 82-87 lbs. tfi> �f,► 18 13/16 M ' 6 1/4 I SK1023 5 8 9/16�• 6 5/16 PA, - - rX I 2" - 11 1/2 NPT 3" -8NPT I I 20 11/16 6 1/4 SK1414 SELECTION GUIDE 1. Integral float operated 2-pole mechanical switch, no external control required. 2. Single piggyback variable level float switch or double piggyback variable level float switch. Refer to FM0477. 3. Mechanical alternator M-Pak 10-0072 or 10-0075. Refer to FMO495 4. Simplex three phase control panel. Refer to FM1228. 5. See FM0712 for correct model of Electrical Alternator. 6. Variable level control switch 10-0225 used as control activator, specify simplex (3) float or duplex (3) or (4) float system. No Molded Plug m CSA Approval without plug. " Three phase automatic available in 230V only. A CAUTION For information on additional Zoeller products refer to catalog on Piggyback Variable Level Float Switches, All installation of controls, protection devices and wiring should be done by a qualified licensed FM0477; Electrical Alternator, FM0486; Mechanical Altemator, FM0495; Sump/Sewage Basins, FM0487; electrician. All electrical and safety codes should be followed including the most recent National Simplex Pump Control, FM1596; Alarm Systems, FM0732; and Disconnect/Rail Systems, FM0787. Electric Code (NEC) and the Occupational Safety and Health Act (OSHA). RESERVE POWERED DESIGN For unusual conditions a reserve safety factor is engineered into the design of every Zoeller pump. © Copyright 2000Zoeller Co. All rights reserved. 2234-02 Tax #1941-274-03-002 JOB NAME. Lot #6, Filing 2, REINHARD Travis Creek Subdivision JOB NO. OB LOCATION f - Ci- UTLC 7 313) BILL TO DATE STARTED DATE COMPLETED DATE BILLED f. 010 6D1 - 7� ' l /ZS fc Y i = l0 L J A 6Aj-z,- 7.5 -4 (lC& 4) S OB COST SUMMARY -ZA cc TOTAL SELLING PRICE P50 _ ra TOTAL MATERIAL O AL LABOR [ S�/ S"Z INSURANCE a. a-Ak3�� (�rz �� SALES TAX - r i�vlD i L rZ a-Kc � L, {6 M ISC. COSTS _ - , nn,, ,4o :i d l� 0� lU rrn� C- �� � Y�i 24 7 &&,��!OTAL JOB COST GROSS PROFIT LESS OVERHEAD COSTS % OF SELLING PRICE NET PROFIT JOB FOLDER Product 278 tS l` at Z234{-UZ / qql- 272-Y-6,3-064 z JA 03 �� ltJoQcaC JOB FOLDER OUA S" -1,c1�f Printed In US.A. 1 k l5'�J23.2,L-OZ l`ill/_27Y .i�o 94MRAMIR-- - DR - - - - - - - A IL _ _ A . c _ e �A we tow Eca B L.P. - F _ R01.!'GT N 02100