Loading...
HomeMy WebLinkAbout139 Elk Range Dr - 239127201008 - 1976-00ISINDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. REPAIR PERMIT NO. 1976R-00 OWNER: PAUL VALENTINE PHONE: 970-963-1113 MAILING ADDRESS: P.O. BOX 28264, CARBONDALE, CO 81623 APPLICANT: KEVIN KING, EMERGENCY EXCAVATION PHONE: 970-945-5519 SYSTEM LOCATION: 0139 ELK RANGE DRIVE, CARBONDALE TAX PARCEL NO 2391-272-01-008 LICENSED INSTALLER:_DREAGER EXCAVATING, GLENN MEEHAN LICENSE NO. 14-00 PHONE: 970-927-3431 DESIGN ENGINEER: PHONE NO. INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 4 BEDROOM RESIDENCE 1250 GALLON CONCRETE SEPTIC TANK, 1500 SQUARE FEET OF ABSORPTION AREA, VIA 48 CHAMBERED UNITS SPECIAL REQUIREMENTS: INSTALL IN SERIAL DISTRIBUTION IN TRENCHES ALONG THE CONTOURS OF THE SLOPE WITH A CLEANOUT BETWEEN THE TANK AND THE HOUSE, AND INSPECTION PORTALS IN EACH TRENCH. DUE TO SITE CONSTRAINTS THE TRENCHES CAN BE INSTALLED FOUR FEET APART INSTEAD OF SIX FEET APART. BE SURE TO MAINTAIN ALL APPLICABLE SET BACK REQUIREMENTS"' THE IRRIGATION DITCH NEEDS TO BE LINED BEFORE THE SYSTEM IS PUT INTO USE IF THE SET BACK CANNOT BE MAINTAINED THE OLD TANK AND DRY WELL NEED TO BE PUMPED AND REMOVED, OR FILLED WITH DIRT. DO NOT BACK FILL WITH ANY ROCKS LARGER THAN 8 INCHES IN DIAMETER CALL EAGLE COUNTY ENVIRONMENTAL HEALTH FOR FINAL INSPECTION PRIOR TO BACK FILLING ANY PORTION OF THE INSTALLATION OR WITH ANY QUEST IONS REGARDING THE INSTALLATION. ENVIRONMENTAL HEALTH APPROVAL: DATE: MAY 24, 2000 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 1500 SQUARE FEET (VIA 48 HD 10 INFILTRATOR UNTTS ) INSTALLED CONCRETE SEPTIC TANK: 1250 GALLONS IS LOCATED 204 DEGREES AND 10 FEET INCHES FROM THE CLEANOUT COMMENTS: FINAL INSPECTION DONF BY T AURA FAWCFTT nN TTTNF 59 9000 SYSTEM TS T ARGR FNOTTCT4 Tn ACCOMMODATE A 4 BEDROOM RESIDENCE. ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. �J �- ENVIRONMENTAL HEALTH APPROVAL /��,( (/� �� �/j / O ((,l /I 1 DATE: JUNE 7, 2000 INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. REPAIR PERMIT NO. 1976R-00 OWNER: PAUL VALENTINE PHONE: 970-963-1113 MAILING ADDRESS: P.O. BOX 28264, CARBONDALE, CO 81623 APPLICANT: KEVIN KING, EMERGENCY EXCAVATION PHONE: 970-945-5519 SYSTEM LOCATION: 0139 ELK RANGE DRIVE, CARBONDALE TAX PARCEL NO 2391-272-01-008 LICENSED INSTALLER: EMERGENCY EXCAVATION, KEVIN KING LICENSE NO. 32-00 PHONE: 970-945-5519 DESIGN ENGINEER: PHONE NO. INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 4 BEDROOM RESIDENCE 1250 GALLON CONCRETE SEPTIC TANK, 1500 SQUARE FEET OF ABSORPTION AREA, VIA 48 CHAMBERED UNITS SPECIAL REQUIREMENTS: INSTALL IN SERIAL DISTRIBUTION IN TRENCHES ALONG THE CONTOURS OF THE SLOPE, WITH A CLEANOUT BETWEEN THE TANK AND THE HOUSE, AND INSPECTION PORTALS IN EACH TRENCH. BE SURE TO MAINTAIN ALL APPLICABLE SET BACK REQUIREMENTS THE IRRIGATION DITCH NEEDS TO BE LINED BEFORE THE SYSTEM IS PUT INTO USE. THE OLD TANK AND DRY WELL NEED TO BE PUMPED AND REMOVED, OR FILLED WITH DIRT. DO NOT BACK FILL WITH ANY ROCKS LARGER THAN 8 INCHES IN DIAMETER CALL EAGLE COUNTY ENVI- RONMENTAL HEALTH FOR FINAL INSPECTION PRIOR TO BACK FILLING ANY PORTION OF THE INSTALLATION OR WITH ANY QUESTIONS REGARDING THE INSTALLATION. ENVIRONMENTAL HEALTH APPROVAL: /V ' DATE: MAY 12, 2000 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: SQUARE FEET (VIA ) INSTALLED TANK: GALLONS IS LOCATED DEGREES AND FEET INCHES FROM COMMENTS: ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. ENVIRONMENTAL HEALTH APPROVAL DATE: M A y -Y-'z i 00 ,.P. FR1(]hi,C—M,. a.vosv.... iTZXJMMi1`I LL'ILlU01X%1D e�LJUL t ; 3T:EAGt$ COUNTY ENV HEA 97WM0349 T0:9455547 P:2016 IncoWlete Applica.tiaZLS Will NOT Be Accepted (Site Flan MUST be attached) // � // IBDS Permit ## _�� �� C {� Building permit # APPItI'CAT3:ON FOR 1=1VIDUAL SENA4E DISPOSAL SYSTEX PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY EAGLE, CO 81631 328-8755/927-3823 (El Umbel) rt#####**ie�leir�Irttt#yk�Ir*i•ic#*�#******isi~**��1r�*�,t*#*��t*****,r*,ryrr,e�r�*�ittir�**��r,rar,r * FEE SCHEDULE * PERMIT APPLICATION FE$ $150.00 PRACOLATION TEST FEE $200.00 +� * 133:Z7 O AND BITE VISIT FEE $85.00 (WEEEN ENV'IROIMEENTAL HEALTH STIES THE * SYSTEK USnM YMM SOILS REPORT) MAKE AL.IL REMITTANCE PAYABLE TO-- "EAGLE C0M4TY-TRF%6WtER" ,► �frMkikkt*ftie#fie# k�tirtieaFi:isti;#t{c*#ekitioibihiit�kiessrt##+1t'+rk*##ir#,}fkrt#ykde#ak#i��F�r�ktiet#ikylrx,r�l1 PROPERTY OWNER : L4 L L. e. N7 � 'rT e - NAILING .ADDRESS : 0 Z?. )x 2— B' 2-,6 _ PHONE; 220-963-ff/s APPLICANT/CONTACT PZRSON: �{��li�i _-.�.' 4� .__. PHONE: LICMSED SYSTEMS CONTRACTOR.- WO A'ca Aplo f e #- PHONE: C[3MPPx1+iYjD$A: m�rry-tzcaV4 FZSS : _ 16'dQ *#'t#iF9F*tilaFkik.t#ir1'�C7t*#7Yi-kiFictw#ek�t*t4vt��hw*tkt�*Ot7kYt*7ki1F*itieicl�t*yktfiakit*!**7k#�Ir#f�kff*drek# PERMIT APPLICATION IS FOR: { 3 NW INSTALLATION ( ) AL'T'ERATION j-;P4 REPAIR I'OCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description: Tax Parcel Number: 17 1r� n 0 L- of Size: 2 Phy8 iaal Addrema :,- BUILDING TYPE: (Check applicable category) 4N4 Residential/Single Family Number cif Bedroom ( ) Residential/multi-Family* Number of Bedrooms i } Co rcial/Industrial* Type -*These systems require design by a Registered Professional Engineer C-r TYPE OF WATER SUPPLY: (Chuck applicable category) ( ) well ( ) Spring ( ) Surf ce (�6 Public Name of supplier : gar :`8 04" e Gft�S "PLICANT SIGNATURE: _ '01 Date: 0.5 -01rf ~ Off] i#*3�'tt4IFk�F#*fftltlewyrf*wWi1k#atiF##f#st#ikw###�r#et#f*#ir*aewlr*+eitt9rt,r:tattlryr7lr*9t*'� AMOU= PAID: _ RECEIPT #: nATE: _ CEECK #. CASHIER: Community Development Department (970)328-8730 FAX (970) 328-7185 TDD (970) 328-8797 Email: eccmdeva@vail.net http: //www.eagle-county.com June 7, 2000 Paul Valentine P.O. Box 28264 Carbondale, CO 81623 EAGLE COUNTY, COLORADO Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 RE: Final of ISDS Repair Permit #1976R-00, Tax Parcel #2391-272-01-008. Property location: 0139 Elk Range Drive, Carbondale, CO. Dear Mr. Valentine: This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Janet Kohl Environmental Health Department Eagle County Community Development ENCL: Informational Brochure Final ISDS Permit cc: files Community Development Department (970) 328-8730 FAX (970) 328-7185 TDD (970) 328-8797 Email: eccmdeva@vail.net http: //www.eagle-county.com DATE: May 12, 2000 EAGLE COUNTY, COLORADO TO: Emergency Excavation Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 FROM: Environmental Health Division RE: Issuance of Individual Sewage Disposal System Repair Permit #1976R-00, Tax Parcel #2391-272-01-008. Property Location: 0139 Elk Range Drive, Carbondale, CO., Valentine residence. Enclosed is your ISDS Repair Permit #1976R-00. It is valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. If you have not been contracted to install this system please contact Eagle County Environmental Health. Also enclosed is the ISDS Final Inspection Completeness Form. The items on this form need to be completed before you call for your final inspection. Also, please note any special conditions which may have been placed on the permit. Do not back fill any part of the installation until it has been inspected. If all items are not completed, a reinspection fee of $42.50 must be paid before a reinspection is made. Please call our office well in advance to allow for scheduling of final inspection. Your building permit TCO will not be issued until final approval has been given for the ISDS Permit. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files Enclosures: ISDS permit # 1976R-00; ISDS Final Inspection Completeness Form Community Development Department (970) 328-8730 FAX (970) 328-7185 TDD (970) 328-8797 Email: eccmdeva@vail.net http: //www.eagle-county.com DATE: May 24, 2000 EAGLE COUNTY, COLORADO TO: Dreager Excavating Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 FROM: Environmental Health Division RE: Reissuance of Individual Sewage Disposal System Repair Permit 91976R-00, Tax Parcel #2391-272-01-008. Property Location: 0139 Elk Range Drive, Carbondale, CO., Valentine residence. Enclosed is your ISDS Repair Permit #1976R-00. It is valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. If you' have not been contracted to install this system please contact Eagle County Environmental Health. Also enclosed is the ISDS Final Inspection Completeness Form. The items on this form need to be completed before you call for your final inspection. Also, please note any special conditions which may have been placed on the permit. Do not back fill any part of the installation until it has been inspected. If all items are not completed, a reinspection fee of $42.50 must be paid before a reinspection is made. Please call our office well in advance to allow for scheduling of final inspection. Your building permit TCO will not be issued until final approval has been given for the ISDS Permit. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files Enclosures: ISDS permit # 1976R-00; ISDS Final Inspection Completeness Form tj-Ait = o 0"olgo ;_ 300 ISDS PERMIT # / 176e OD y.ySZ PERCOLATION TEST EAGLE COUNTY ENVIRONMENTAL HEATLH .OWNER: V4len/7*/7e- - -PHSYSICAL ADDRESS: 1341 Clk A-, LEGAL DESCRIPTION: MAILING ADDRESS: TYPE OF DWELLING: �.5. f�, NUMBER OF BEDROOMS: L( TEST HOLES PRE-SOAKED: YES ✓ NO SOIL TIME WATER DEPTH INCHES OF FALL RATE PROFILE (y 'I 2' i dy'ly J /0 51 3® l9'1,2, ay ;�o 3� l9°Jz- aH''ff 6� t - `fo ';10 g� Alo q s� '� '�� V '/8 1l1 qa � ; 1 �a �9 jay a7- �3 , r 10' TIME TO DROP LAST INCH: PERC RATE: �� MINIMUM LEACH FIELD SIZE: MINIMUM SEPTIC TANK SIZE: Z,2V) Sry/h't 14, 5l� 900 x o l _ _ ENVIRONMENTAL HEALTH SPECIALIST DATE 1, � 641/ 't� de -rul 1 ra7.,n4nm Tm.r-n1 P Fill IA ITV —111 11-1 — ISDS Permit # I9"7 — 0 O Inspector Date/a ISDS Final Inspection Completeness Form Tank is Q56jal. Tank Material Tank is located ft. and degrees from 7� (permanent landmark) Tank is locatedy ft. and �degrees from Ag�L1 O � % / (permanent landmark) " Tank set level. ✓ Tank lids within 8" of finished grade. Size of field ft2 units lineal ft. Technology 14D / D Cleanout is installed in between tank and house(+ 1/100ft). y "T" that goes down 14 inches in the inlet and outlet of the tank. Effluent filter on outlet- Yes or No Inlet and outlet is sealed with tar tape, rubber gasket etc. Tank has two compartments with the larger compartment closest to the house. Measure distance and relative direction to field. `v a� �$ t Depth of field i - �' ft. OK Soil interface raked. - Q A V Inspection portals at the end of each trench... Paw" akz"Ic 6 Proper distance to setbacks. K 0 Chambers properly installed as per manufacturers specifications. (Chambers latched, end plates properly installed, rocks removed from trenches, etc.) Splash plate(s) installed at least in first trench inlet. P303q ^ ! ✓Type of pipe used for building sewer line , leach field 4 Other 5a Inspection meets requirements. Copy form to installer's file if recommendations for improvement were suggested. ACTION TAKEN: Setbacks Well Potable House Property Lake Dry Tank Drain Water Lines line Stream Gulch Field 100 25 20 10 50 25 10 10 Tank 50 10 5 10 50 10 * 10 JOB 2--7 ru_oL ji ut E-AG-LE`--C-Oi�l+T-Y--E-RV- -HEALTH P.O. BOX 179 SHEET NO. OF EAGLE, CO 81631 CALCULATED BY DATE a CHECKED BY DATE 6K- $10av 14 .................. ........... ............ . ............. .... . ...... .............. ............ w ('j 541 I I.- --� .............. 1 1. .—M. -- 1 —1— 1-11—ft 1976R-00 Tax #2391-272-01-008 Lot #27, Red Table VALENTINE JOB NAME 0139 Elk Range Drive JOB NO. Carbondale r DATE STARTED DATE COMPLETED DATE BILLED %�. .�' ILA 1� t.�. % '. - �!; •.-�.�/.���/ rL.� w eg r WKWAMI ilip WMAIWIOWIMM W/04 JOB COST TOTAL SELLING PRICE / TOTAL MATERIAL MIES 0 J WIANMM�00 TOTAL LABOR MIN E, 19, FIX M4 .4wmm wo "n MIN TOTALp • C COST, _ ■ PROFITGROSS _■ LESS • OVERHEAD COSTS- _■ JOB FOLDER Product 277 JOB FOLDER ce Printed in USA V kvvv� "- o OD s _ 0 {3q �cl ru Ca cbuK&,�, t ��! V� zwf� c a�� --G 0,,,t[CP —,�-7a c;.) Va I eylt � e J))e c J