Loading...
HomeMy WebLinkAbout7738 Frying Pan Rd - 246908202006INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1965-00 BP NO. 1-N60 - 13 3 81 OWNER: RICHARD BENES PHONE: 303-741-4500 MAILING ADDRESS: CMC GROUP, 2450 SOUTH DOWNEY STREET, DENVER, CO 80210 APPLICANT: RAUL GAWRYS PHONE: 970-927-4411 SYSTEM LOCATION: 7733 FRYING PAN RD., BASALT, CO TAX PARCEL NO 2469-082-02=006 LICENSED INSTALLER: SHAG'S EXCAVATING, MIC14AEL STEHLING LICENSE NO. 54-00 PHONE: 970-927-4110 DESIGN ENGINEER: HIGH COUNTRY ENGINEERING, ROGER NEAL PHONE NO. 970-945-8676 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 5 BEDROOM RESIDENCE 2000 GALLON SEPTIC TANK, 1000 GALLON DOSING TANK EQUIPPED WITH BOTH AUDIO AND VISUAL ALARMS 1406 SQUARE FEET OF SAND BASE MOUND AREA, AND 979 SQUARE FEET OF GRAVEL BASE AREA, PER ENGINEER'S DESIGN. SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN REVISIONS DATED 4/20/00. THE EXISTING TANK AND LEACH FIELD ARE TO BE REMOVED AND REPLACED. MAINTAIN ALL APPLICABLE SET BACKS ADDING AN ADDITIONAL 8 FEET DUE TO THE DESIGN FLOW OVER 1000 GAL- LONS PER DAY (1125 USED.) ENGINEER IS RESPONSIBLE FOR FINAL INSPECTION. DO NOT BACK FILL ANY PART OF THE INSTALLATION UNTIL THE ENGINEER HAS INSPECTED AND APPROVED THE INSTALLATION. BUILDING CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS RECEIVED FINAL APPROVAL. ENVIRONMENTAL HEALTH APPROVAL: /1Y- �'�,{�� DATE: SEPTEMBER 15, 2000 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 1406 SQUARE FEET (VIA RAISED MOUND DESIGN ) INSTALLED CONCRETE SEPTIC TANK: 2000 GALLONS IS LOCATED 90 DEGREES AND 7 FEET INCHES INSTALLED CONCRETE DOSING TANK: 1000 GALLONS IS LOCATED 90 DEGREES AND _7 FEET INCHES FROM THE NORTH WEST SIDE OF THE GARAGE FOUNDATION. SE DESIGN DATED 5-10-01. COMMENTS: FINAL INSPECTION DONE BY THE DESIGN ENGINEER ON MAY 21, 2001, AND WILLIAM CARLSON OF ENVIRONMENTAL HEALTH ON MAY 22, 2001. ENGINEER FINAL CERTIFICATION RECEIVED MAY 29, 2001. THIS SYSTEM IS LARGE ENOUGH TO ACCOMMODATE A FIVE BEDROOM RESIDENCE. ANY ITEM NOT MEETING REQUIREMENTS WILL E CTED FO PROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. I ENVIRONMENTAL HEALTH APPROVAL DATE: JUNE 12, 2001 Incomplete -Applications Will NOT Be Accepted (Site Flan NUST be attached) ISDS Permit i Isv fq6y- 6 Building Permit # 130(a_()_ APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERNIT ENVIRONMENTAL HEALTH OFFICE_ --EAGLE COUNTY P. O. BOX 179 EAGLE, CO 81631 328-8735/927-3823 (Basalt) * PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FIDE $200.00 * MAKE ALL REMITTANCE PAYABLE•I'0: "EAGLE COUNTY TREASURER" PROPERTY OWNER: MAILING ADDRESS: APPLICANT/CONTACT'PERSON: LICENSED SYSTEMS -CONTRACTOR: COMPANY/ DBA : 1,l L ADDRESS: PERMIT APPLICATION IS FOR: 0 NEW INSTALLATION LOCATION OF PROPOSED INDIVIDUAL SEWAGE noel d � PHONE PHONE: Z11 L44qNE ( ALTERATION ( ) REPAIR SYSTEM: Legal Description: 'k1 i q(. / W(L�{' l I LM4, I Tax Parcel Number:- �0 Physical Address: BUILDING TYPE: - (Check applicable category) • Residential/Single Family (.) Residential/Multi-Family* ( ) Commercial/Industrial* Lot Size: Number of Bedrooms c. Number of Bedrooms Type TYPE OF WATER SUPPLY: (Check applicable. category) Well ( ) Spring ( ) Surface ( ) Public Name of Supplier: *These systems re design by a Registered Professional -Engineer SIGNATURE: Date: AMOUNT PAID: ��RECEIPT 1: qO I w08 DATE: CHECK #: ML4 CASHIER: Community Development Department (970) 328-8730 FAX (970) 328 7185 TDD (970) 328-8797 Email: eccmdeva@vail.net http: //www.eagle-county.com June 12, 2001 Richard Benes CMC Group 2450 South Downey Street Denver, CO 80210 EAGLE COUNTY, COLORADO Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 RE: Final of ISDS Permit 41965-00, Tax Parcel 92469-082-02-006. Property location: 7733 Frying Pan Road, Basalt, CO. Dear Mr. Benes: This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Janet Kohl Environmental Health Department Eagle County Community Development ENCL: Informational Brochure Final ISDS Permit cc: files Apr-iu-tuuu uf:57am Prom-CMC GROUP 3037414549 T-132 P-002/0O5 F-389 Gec�tech March 20, 2000 Richard Benes 2450 South Downey Street Denver, Colorado 80210 Repworth-P"awlak Ceotechnical, Inc. 5112O Counly Road 154 Glenwood Springs, C:oluratlo 81601 Phone-970-945-7988 Fax:970-aa5-8454 hpgeo@hpgCoWOh,eam Job No _ 100 203 - Subject: Percolation Testing, Proposed New Septic Disposal System, 7738 Frying Pan Road, Eagle County, Colorado. Dear Mr. Bergs: As requested, a representative of Hepworth-Pawlak Geotechnical, Inc_ conducted percolation testing at the subject site to evaluate the feasibility of an infiltration septic disposal system. The results of our work are presented in this report. The work was done in accordance with our agreement for professional services co you, dated February rrr A profile pit and three shallow backhoe pits were excavated at the locations shown on Fig. 1. Percolation test holes (nominal 12 inch diameter by 12 inch deep) were hand dug at the bottom of the backhoe pits and soaked with water one day prior to testing. The holes were covered with rigid foam insulation to protecr against freezing overnight. The soils exposed in the percolation holes are similar to those exposed in the profile pit and consist of 1 V2 feet of topsoil overlying silty sand and gravel with cobbles to the pit depth of S feet. Groundwater was encountered in the profile pit at a depth of 5 feet and the upper soils were moist to very moist. Percolatioa tests were performed oa March 7, 2000 by a representative of Hepworth- Fawlak Geotechnical, Inc. The percolation test results are presented on Table I, .Percolation rates less than about 1 minute per inch were rrleasared.. The slower rare at \11'1 test hole P-2 was due to finer soils encountered. The fast percolation rates measured ❑P17-1 fit-pGImn mnKi 917- rQOM Tfi- r-70Q C rn) IhITV M'K11 I UC7nl TU on'-=. �-) Apr-JU—Z000 U7:532m From—CMC GROUP 3087414549 T-132 P-003/005 F-380 Richard $eves March 20, 2000 Page 2 and the shallow groundwater level will probably require an engineered septic disposal system. A civil engineer. should be contacted for the design. If there are any questions or if we may be of further assistance, please let us know. Sincerely, HEPWORTH - PAWLAK CEOTECHNICAY.,, INC. Jordy Z, Adamson, Jr.j P. Rev. by: SLP JZA/ksm attachments t 29707 �j ' IONA1- cc: High Country Engineering - Attu: Deric Walters H-P GEOTECH dDD_I M-D::)M M MnK1 M7. CDOM Trl. 1=nf=1 C f'fl1 1k1-rV Chll I LIC'nI -rU mne-=. -2 Apr-iu—cyuu ur:ouam Prom- m uxuuP 303T414549 T-132 P.004/005 F-389 100 203 1 r I R t APPROXIMATE SCALE 1n m 4 OVERFLOW CHANNEL A 3 P ROE` ILE PIT r A P 1 A t t � RESIDENCE � Z ( TO RE REMODELM) .O^ �`- �,. .� "� EXISTING ! •,/ -- DRIVEWAY,., •"' J PROPOSED � 2—STORY GARAGE � HEPWORTH --• PAWLAK I LOCAMON OF PERCOLATION TEST HOLES � Fig. 1 GEOTECHNICAL, INC. OPP- IM-aGlfiM MnKl M7-I-,40M Tll-COfI C f"111IKITV CFJI I UMnl TU anr_c.A Apr-IU—qUU U7:5IIam From-= GROUP 3037414549 HEPWORTH-PAWLAK GEOTECHNICAL, INC. T-132 P.005/005 F-389 TABLE I PERCOLATION TEST RESULTS JOB NO. 100 203 HOLE NO. HOLE DEPTH (INCHES) LENGTH OF INTERVAL (MIN) WATER DEPTH AT START OF INTERVAL (INCHES) WATER DEPTH AT END OF INTERVAL (INCHES) DROP IN WATER LEVEL (INCHES) AVERAGE PERCOLATION RATE (MINANCI.1) P-1 • - - 36 1 - - - 11 7 4 __ _ C1 7 4 3 4 g��/+--� 1 1/4 -- -. __ _ -._ . 1 _7i ._ - _ r2I - f8 1 % 113 1 P-2 P-3 28 28 10 1 5% 5 20 <1 5 4 1/s '12 4 34 4 4 3 'A s/4 3 1/4 2% Y2 2 74 7 2 '� 4 �f9 4 2 2 2 d 2 Note: Percolation test holes were hand dug in the bottom of backhoe pits and soaped on March 6, 2000. The test holes were covered with rigid foam insulation to protect against freezing overnight. Percolation tests were conducted on February 7, 2000. The average percolation rates were based on the last two readings of each test. Test P-2 had a slower rate due to finer soils encountered in the test hole. d06_4 M—OMMM MnKI M7. C'OnM Trl. En 'I C f'r-11 IhITV Ckll I L=nf -rU mne=. C IL Engineering Department (970) 328-8760 FAX (970) 328-7185 TDD (970) 328-8797 EAGLE COUNTY, COLORADO September 5, 2000 Mr. Paul C. Currier, P.E. Water Resource Consultants, LLC 244 Hutton Ave. Rifle, CO 82350 Eagle County Building P.O. Box 850 500 Broadway Eagle, Colorado 81631-0850 IN RE: Issuance of Floodplain Development Permit for Richard Benes Property Permit # 2000-009 Dear Mr. Currier: I received your revised application for the above referenced Floodplain Development Permit on August 25, 2000. 1 have reviewed your application and the supporting documentation. In response to this submittal I have the following comments. l . Although it appears that this residence is in fact located entirely in the flood fringe district as per your study, the changes made to the site plan have resulted in a structure which is more compliant with the spirit of the Floodplain Regulations. Specifically, an existing partial basement will be eliminated, thereby eliminating areas within the structure that will be prone to inundation by the base flood. Furthermore, since the southern most corner of the existing residence will be removed the setback from the floodway-flood fringe boundary will increase from 9' to 15'. This brings the structure into compliance with Section 6.06.20 4)a)1) which stipulates that any residential building designed for human occupancy shall be constructed, located or improved so that any external wall shall be not less than 15' from the streamside of the flood fringe district. 2. Section 6.06.20 4)a)2) stipulates that the structure must be at least 1' above the base flood elevation. As indicated in your application all existing floor levels will be raised as needed to be a minimum of F above the base flood elevation of 7065.4. 3. In accordance with Section 6.06.29 5) "the Floodplain Management Administrator may waive any part but not all of the submission requirements imposed by Section 6.06.25 of these Floodplain Regulations upon petition of the applicant that a portion of the submission requirements is inapplicable to the development for which the permit is sought, and/or full compliance with the submission requirements would be unreasonably burdensome for the applicant and that the proposed development will have an insubstantial impact on the surrounding area. Such a waiver may be granted, after due consideration by the Floodplain Management Administrator, upon a written determination that the information to be submitted is sufficient for the Floodplain Management Administrator to arrive at a permit decision in full compliance with the law and these Floodplain s Regulations and that the proposed development will have an insubstantial impact on the surrounding area." In accordance with this section of the regulations, I am waiving the requirement of Section 6.06.04 of the Eagle County Land Use Regulations that stipulates that "in no instance shall the floodway-flood fringe boundary be closer than 25' to the natural stream bank." This requirement is not demanded by the NFIP and in order for you to comply with this section, the existing home would have to be relocated off its current foundation. Clearly, the remodeled structure will be far more equipped to deal with any potential flooding due to the many improvements you are making to the structure. Therefore, I am approving your application for a Floodplain Development Permit for the Benes property. Enclosed please find one copy of Eagle County Floodplain Development Permit #2000- 009. Please feel free to call me at (970) 328-8760 if you have any questions. Sincerely, EAGLE COUNTY ENGINEERING DEPARTMENT It --- Helen Migchelbrink, P.E. County Engineer Enclosure xc: Matt Gennet, Planner Raul Gawrys Richard Benes chrono/file 11n I —cz1—U t 1 UC Ua , J4 rill n RTM UUUN I KT CIYU 1 IYMK I NU t iA NU, 41 U H4b �5hb May 29, 2001 Fagle County Environment -al Health l3cpartment Attn: Hill Carlson P. 0. Box 179 Eagle, CO 81631 Re, 7733 Frying Pan Road, Eagle County, Colorado HCE File Number 2000004.05A Dear Ray: On May 21, 2001, High Country Engineering personnel observed the construction of the 1SDS for 77331~rying Pan Road, Basalt within. Eagle County, Colorado, One 20()0-ballon septic tank, one l000-gallon concrete dosing tank cha►nber without appurtenances and an absorption hound had been installed, but no bacrkfilling had taken place. Pump specifications were verified and the contractor was directed to drill additional holes on the bottom of the distribution laterals. Otherwise, the installation of the system was in conformance with the intent of the design dated May 10, 2001. If you have any questions, or need additional information, please contact us. Sincerely, HIGH COUNTRY ENGW rERING, INC. Roger Neal, P.E. Project Manager RDNrdjw 923 Ciwper Avenuc, 14 lrwynus; Drive Fast Suite 13-144 Ulunvrorxl 5pri11SN CO 81601 F,n,�lcwood; CO 30112 TclLphonc(970) 945.9676 • Fax (970) (95-2555 TdLplwne (303) 925-0544 -11iz (303) 9'35-0547 ISDS Permit # I C7C*,E. oo Date ISDS Final Inspection QaRleteness Form Tank is gal. Tank Material Tank. is located �f t . and �- degrees from (permanent landmark) Tank is located ft. and degrees from (permanent landmark) Tank set level. 1- S Tank lids within 8" of finished grade.'f Size of field y07 ftz units lineal ft. Technology. �7� S Cleanout is installed in between tank and house(+ 1/100ft). '%e 5 There is a "T" that goes down 14 inches in the inlet and outlet of the tank: . Inlet and outlet is sealed with tar -,tape, rubber gasket etc. = T�k has- two compartments with the 1 anger..:;cgtgpartment closest to the,,.:,..,,. . house. l f " measure. distance and relative directjon;to;.fie.ld; Depth of field. f�t:✓ac� e� °. Ssoil interface raked. -' Inspection portals at the _end of each trench.. Proper distance to setbacks. C�� -Chambers properly installed as per manufacturers specifications. (Chambers latched, end plates properly installed, rocks 'removed from trenches, etc.) Type of pipe used for building sewer line_*' leach field Other Inspection meets reguirements. Copy form to installer's file if recommendations for improvement were suggested. , ACTION TAKEN: � Gr � q �_ � f(S I N .1�� � c1 rot-) 5`'rS��w, i � � g�"f'� cis �� �. �.�•;,���. Setbacks Well Potable House Property Lake Dry Tank Drain Water Lines line Stream Gulch Field 100 25 20 1025 10 10 Tank 50 10 5 10 i 5� 10 * 10 1965-00 Tax #2469-082-02-006 Lot #6, Peach Blow BENES JOB NAME 7733 Frying Pan Rd., Basalt JOB NO. b P /�/0 1�'/9 M LVGAI IVN / 9 I BILL T DATE STARTED DATE COMPLETED DATE BILLED ill oa /7l�iY✓ �C S Q F Y �o f oiu a f C Qo tfG (Cin d am' cA S,-zc a eaC/4%G%� 5 2 o a led f" J Gt"Gf�;6�c t !/�SUa l . N,4.4,(or JOB COST SUMMARY �eG{ = l�� fz (�� ve/ base a �, 3 SQL �, /j 6�se TOTAL SELLING PRICE 1115 fC/ of Aie(lS !n L5(nl%Gl • �2��0 . � 'ie ,'� TOTAL MATERIAL /il s rK /l 71 m h 1 QQ�GL, Qir� d '�j �� TOTAL LABOR M 61 0,AZ 61� 16,40 ue� �/(�. f J INSURANCE 61), & b S h in # a �GG�f�nfYit S jlVe!," SALES TAX S r ✓1 OZc,F� f i K = ,.r(,l ��y/� S M ISC. COSTS IJ TOTAL JOB COST aoInLlk 441(-' GROSS PROFIT LESS OVERHEAD COSTS % OF SELLING PRICE CY S , i �� •�'� '� l'c s�S-�1 �' �'I , S', t // n . .- �i ET PROFIT JUb rvwt SOB FOLDER In U.5.7 ff z--OW �; e - C,- (Op / jra Y�- 41L, A '0. c), fj( A ; 4S I 12 c< 12-1 > QQ b:b ZI e Recycled Content 10% Post -Consumer FRYING PAN ROAD BED OF 1-1/2" SCREENED ROCK, (12" MIN. THICKNESS) - DISTRIBUTION SEE NOTES FOR MIN. BASE AREA ` FILTER FABRIC LATERAL 12" MIN GRAPHIC SCALE ANCHORAGE FOR SEPTIC TANK TOPSOIL COVER 20 0 10 20 40 80 3 #4 REBAR (MIN) AND DOSING TANK 3 MIN. - - TIE DOWNS 1 C.Y. WEIGHT BLOCK EACH E OF TANK - - 4' • -� 1 D (MAY BEPRECAST OR CAST IN PLACE) SAND FILL, SEE NOTES - 2' MIN. - ( IN FEET ) FOR MIN. BASE AREA Y 1 inch = 20 ft. 1.5' WELL GRADED PIT RUN PLOWED SURFACE - 4.0' MIN. MATERIAL (6" MINUS), FREE OF ` TO MOTTLED FINES, MUST BE USED FOR LA�R SECTIONLBAWSAD NOTE: ANCHORAGE REQ'D FOR DOSING TANK IF Boa d EXPECTED GROUNDWATER TABLE ABOVE FLOOR OF TANK.F-an _ - TANK ANCHORAGE DETAIL 7 Frying - - _ PROPERTY BOUNDARY SECTION VIEW TH R U TANK N.T.S. i TOE OF BANK ` - INSTALL 2-1 /2"0 _ o CALIPER TREE BETWEEN TREATED ELEC. JCT. BOX _ BETWEEN DRIVE POST Z TO AND MOUND GROUND) SURFACE- 2 #4 BARS u- 2" AIR VENT ` I - CAULK/SEAL WELL FEEDER -- - _ -_- - aNmr MAP 2- F DER LiM1iE TO AT 100 Y FI INLET_= _ - -- _ -- 1/8D�PER FTDMIN. SC 1 = 40 (�T1 Year oo Icln -- - = SHALL DRAIN BACK r d P TO TANK AFTER GENERAL NOTES 0 EACH PUMP CYCLE. rn 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE EAGLE COUNTY f �rw PROPOSED DOSING-,, - _ REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS TANK Z ��_� CT► "ALARM" - AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. PROPOSED 1500 GAL. 2. SYSTEM ES I I TOE OF GRAVEL N QUICK DISCONNECT SEPTIC TANK (MIN.) r OR UNION GN INSTALL 10 MIL PVC 20. TOE OF SAND Q FLOW: 5 BEDROOMS •2 PERSONS/BEDROOM *75 GALLONS/PERSON/DAY IS LINER ON RIVER SIDE TOE _OF PLT RUN OW AVERAGE DAILY F 750 GPD =L�' mz DESIGN = 1.5 AVERAGE = LOW1125 GPD OF TANK P 2"0 . SCHEDULE 40 PVC - o "oN" COIL AND TIE AN FROM DOSING TANK TO _ m ADDITIONAL OF SEPTIC TANK: MINIMUM PRE -CAST CONCRETE TANK SIZE ACCORDING TO SEPTIC FIELD_ GRADE r i WEIGHT WIRE FOR PUMP REGULATIONS IS 1500 GALLONS. RECOMMEND 2000 GALLONS. REMOVAL *MINIMUM FIELD SIZE: PER CDOH EQUATIONS: BACK TO DOSING TANK t Ld A = QV_t Q = MAXIMUM FLOW \ _ 0 SUBMERSIBLE WASTEWATER PUKP ;! p 5 t = PERCOLATION RATE = 20 �� �?��F� �o �Zi��� S- a- co"OFF" O O SET PUMP APPROX. A = 1 125* V20 = 1007 SQ. FT 8" OFF FLOOR 5 4.1- x *MINIMUM FIELD SIZE: FOR SAND FILTERS AND MOUNDS C_EANOUT J �� -� MINIMUM GRAVEL BASE AREA: 1 125 GPD (;YP-) DOTES: A= ; 1.15 GPD/S.F. = 979 SQ. FT. 1. SWITCHES TO BE MERCURY FLOAT TYPE. 4"0 P V� SEWER .o / \ 2. FLOAT SWITCH DIMENSIONS ARE BASED ON A COPELAND 1000 GAL. TANK. #»*GAARBAGE GRINDEERSLOADING RATE OF IBESREMOVEDFFROMQALL R THAT ALL �� TO BE WRAPPED (CISTERN) _ RESIDENCES. \ 3. DOSING TANK SHALL BE OF WATERTIGHT CONSTRUCTION. F<C WITH 10 MIL PVC / 4. ALARM SHALL BE BOTH AUDIBLE AND VISIBLE, LOCATED WITHIN MINIMUM SAND FILL BASE AREA: A- 1125 GPD LINER �.1G THE HOUSE AND ON A CIRCUIT SEPARATE FROM THE PUMP. 0.8 GPD/S.F t= 1407 SQ. FT. \ EX SE 5. PUMP SHALL BE CAPABLE OF AT LEAST 50 GPM 0 15 FT. OF HEAD. \ NOV (ELEVATION DIFFERENCE AND PIPE LENGTHS SHALL BE FIELD MEASURED BY *GRAVEL AREA CONTROLS MINIMUM FIELD DIMENSIONS BY MEANS OF MINIMUM j / CONTRACTOR AND REFERRED TO ENGINEER FOR VERIFICATION OF PUMP PARAMETERS. SIDE SLOPE OF 3:1. ABSORPTION AREA PROVIDED BENEATH SAND IN MOUND=2400t S.F.-WHICH IS GREATER \ 6. FIELD WIL BE DOSED AN AVERAGE OF 3 TIMES PER DAY AT 450 GALLONS PERTHAN THE MINIMUM OF 1007 S.F. \ AS REQUIRED PER THE PERCOLATION RATE. DOSE, GIVEN THE FLOW ARRANGEMENT ABOVE. __ -- - -- - = -- - ----- - _ SETBACKS -- _- - --- -__-_ �--- DOSING TANK ARRANGEMENT , - - / - - --- - MOUND: PT I I N AN I WELL = 110 FEET WELL RIVER = 50 FEET CONTRACTOR TO VERIFY N.T.S. RIVER = 60 FEET - - BUILDING = 5 FEET BUILDING = 20 FEET MOUND = 10 FEET \ DISTANCE FROM TANKS/PROPERTY LINE = 10 FEET / - NEIGHBORING WELL \ / MOUND SYSTEM SPECIFICAl10NS 3. TOPSOIL: SOIL EXCAVATED FROM SITE ACCEPTABLE IF NO CLAY IS PRESENT. / 4. VEHICULAR TRAFFIC IS PROHIBITED ON THE FIELD. / 1. AND SREMOVEDBFROMDTHE ESSITEHALL BE CUT CLOSE TO THE GROUND SURFACE t 5. CLEANOUTS ARE REQUIRED AT ALL BENDS AND AT LEAST .EVERY 100 \ IL 110' ETBACK BETWEEN FEET ALONG THE HOUSE SEWER. 4 MO ND AND NEW WELL ` 2. THE MOUND SITE SHALL BE TILLED TO A DEPTH OF 8 INCHES TO ROUGHEN THE 6 "11� Frying Pay River SURFACE r r 1. 5' TOPSOIL _ 2 5' DRILL 1 /4"0 HOLES 48" SILTY SAND ON CENTER FOR ENTIRE 4 AND GRAVEL LENGTH OF ALL LATERALS WITH COBBLES 48" MOTTLED LAYER 48" d . (DESIGN CONSTRAINT) 24 2" PVC LATERALS d E v �pF SL HOLES ON BOTTOM 30�'f S OF LATERAL d SOP 26.2 t 2"x 2" TEE' v 5� GROUNDWATER '21 F S�OpF t 45.0' NOTE: ALL PIPING MUST DRAIN BACK TO DOSING TANK LATERAL PIPE LAYOUT (FOR PRESSURE DOSING OF FIELD) N.T.S. OBSERVED SOIL PROFILE 17 N.T.S. 4.75' TYP. 26. 2" SCHEDULE 40 PVC OR 200 PSI POLYETHYLENE FROM DOSING TANK `-APPROX. WELL LOCATION TOE OF SAND ` AREA - 2200 S.F. TOE OF PIT RUN SURFACE AND INCORPORATE THE VEGETATION. THIS CAN BE DONE WITH A INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO PLOW OR CHISEL TEETH MOUNTED ON A TOOL BAR ATTACHED TO THE BUCKET WITHIN 1/2-FOOT OF FINAL GRADE. OF A BACKHOE. I 7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG 3. A LAYER OF SAND SHOULD BE PLACED ON THE TILLED AREA. PLACEMENT OF AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. THE SAND SHOULD BE SUCH AS NOT TO RUT OR COMPACT THE TILLED AREA. ALL WORK SHOULD BE PERFORMED FROM THE SIDE SO AS NOT TO COMPACT 8. I PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM SURFACE THE TILLED AREA. ABSORPTION AREA USING DRAINAGE AS NECESSARY. 4. PLACE THE PROPER DEPTH OF SAND, THEN FORM THE SAND/GRAVEL INTERFACE ( 9• PERCOLATION TESTING PERFORMED BY HP GEOTECH IN MARCH, 2000. AREA WITH THE AREA BOTTOM BEING LEVEL. �10. THIS DRAWING DOES NOT CONSTITUTE AN ISDS PERMIT. (PERMIT MUST 5. PLACE THE SCREENED ROCK (AGGREGATE) TO THE SPECIFIED DEPTH AND AREA. BE OBTAINED FROM APPROPRIATE CITY OR COUNTY OFFICIALS. 6. PLACE THE PRESSURE DISTRIBUTION PIPE, CONNECT IT TO THE SEWER AND 11. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR ' COVER WITH AGGREGATE. FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM.; 7. COVER THE AGGREGATE WITH A GEOTEXTILE FILTER FABRIC. j (12. THE SAND MUST BE THOROUGHLY SETTLED BY FLOODING OR;OTHER MEANS 8. PLACE A MINIMUM OF 12 INCHES OF SUITABLE SOIL COVER ON THE SIDES OF THE BEFORE THE DISTRIBUTION IS PLACED AT THE FINAL GRADE. MOUND AND TO THE NECESSARY DEPTH FOR GRADING ON THE TOP OF THE MOUND. i �13. SAND USED SHALL BE AS FOLLOWS: 9. FINAL GRADE THE MOUND AND SURROUNDING AREA WITH LIGHT WEIGHT EQUIPMENT i I; SO SURFACE WATER MOVES AWAY FROM THE MOUND AND DOES NOT ACCUMULATE I SIEVE SIZE %PASSING NEAR THE MOUND. , 4 100 40 50-55% 10. SEED AND MULCH THE ENTIRE EXPOSED AREA TO AVOID EROSION. LANDSCAPE ' I 200 <15 I WITH SHRUBS AND PLANTS AS DESIRED. _ I IN I FOR?vt TY- COEFF IC LENT=D„/ D,oi!EA I TYPICALLY CONCRETE OR MASONARY SAND IS ACCEPTABLE.G j 14. REVISED SITE PLAN PROVIDED BY RAUL GAWRYS ARCHITECTURE, MARCH 2O01. '15. DESIGN OF MOUND SYSTEM BASED ON ENGINEER'S OBSERVATION OF 1.5' OF i TOPSOIL OVER SILTY SAND AND GRAVEL WITH COBBLES. GROUNDWATER OBSERVED AT A DEPTH OF 4' WITH MOTTLING OBSERVED AT A DEPTH OF 2.5'. 3• PVC CAP •DE D,''..%�l` FINISH GRADE I TION WELL----* 9' 4.5�- l = �t 9715 EMOVABLE CAP )FON 18.5' P PES4 - 1/2"0 HOLES 70NALEN�\` T I 35' 4" COUPLING SOLID PIPE i 4" RISER ? COUPLING 1 4" 45' SWEEP BEND `^--� 4" SEWER LINE--\ SOLID CAP FOR ~ SUPPORT ® BOTTOM O PERFORATED PIPE OF TRENCH OR BED WRAPPED WITH (BOTTOM OF SAND) O FILTER FABRIC FLOW j - '�' 4.5' 4"x4"x4" 71.4 C 0 M B I N A TI 0 N A I r VENT 8c PVC wYE I AssEMB Y PLAN VIEW OF MOUND INSPECTION WELD DETAIL SEWER CLEAN OUT DETAIL t N.T.S. N.T.S. N.T.S. i 0 m o 0 0 0 F- i.: < r O j F- - w uj U of 0 W .-. W H � � Q O 0 ^ 0 O Z v W p Z W z < O H N Lj W < 2 M J h-- W X - Cr H w N w O 3 Z w w w a a a ft 0 16- 0 0 0 W < < < H J -1 J 0 0 0 0 z z z o U ;=0 O w w w w W \ \ \ Q o a n o d LO p N N) ar t1•) Z 0 0 Z w p o\ Z N Lj cr_ � V1 m U-) O LLJ w w Y Q -j C:) C) U m sC14 �W�� U"O W 'r - ��= W �� >- UQa°G° C4 V U ,^ O W CIO o -j O w o Z (L m o I- � Z Z (� < Q U0 tr LLI J t") C7 w Q Z PROJECT NO. 2000004.05 SHEET 1 OF 1 w.