Loading...
HomeMy WebLinkAbout251 Daggett Ln - 211120200044INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, Colorado 81631 Telephone: 328-8755 YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1347 Please call for final inspection before covering any portion of installed system. OWNER: George & Dana Gerard PHONE: 328-6584 MAILINGADDRESS: P.O. BOX 532 City: Eagle stage: CO ZIP: 81631 APPLICANT: Bruce Bair /High Country Builders Of Gypsum PHONE: $XI 524-9421 SYSTEMLOCATION: 251 Daggett Lane TAX PARCEL NUMBER: 2111-202-00-006 LICENSED INSTALLER: Bruce Bair LICENSE NO: 34-94 DESIGN ENGINEER OF SYSTEM: INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: 12 GALLON SEPTIC TANK ABSORPTION AREA REQUIREMENTS: SQUARE FEET OF SEEPAGE BED 1208 SQUARE FEET OF TRENCH BOTTOM. SPECIAL REQUIREMENTS: Install 32 infiltrator units in trenches or 420 lineal ft SB2 in trenchs. Install inspection portals at the end of each trench. TRENCHES only no bed system. Call for a final inspection prior to backfilling ENVIRONMENTAL HEALTH APPROVAL: 6a�4-�4� ZZ DATE: CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25. 10- 104. 1973. AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICHMAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 1208 SQUARE FEET. INSTALLED SEPTIC TANK: 1500 GALLON 0 DEGREES 34 FEET FROM the house. SEPTIC TANK ACCESS TO WITHIN 8" OF FINAL GRADE AND PROPER MATERIAL AND ASSEMBLY X YES NO COMPLIANCE WITH COUNTY / STATE REQUIREMENTS: X YES NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS CORRECTED. COMMENTS: If ENVIRONMENTAL HEALTH APPROVAL: DATE: ENVIRONMENTAL HEALTH APPROVAL: DATE: (RE -INSPECTION IF NECESSARY) RETAIN WITH RECEIPT RECORDS APPLICANT / AGENT: OWNER: PERMIT FEE PERCOLATION TEST FEE RECEIPT A CHECK A ;ncomplete Applications Will NOT Be Accepted (Site Plan MUST be attached) ISDS Permit #y Building Permit # APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. 0. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (Basalt) ************************************************************************** * PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 * * * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" PROPERTY OWNER: G 569a--6-L A- 6,242J MAILING ADDRESS: �//, 53.E �/� PHONE: ��' APPLICANT/ CONTACT PERSON: ,Q,� rtc ,�,(2 PHONE: � -ZY - LICENSED SYSTEMS CONTRACTOR: S41` 1 PHONE: szy- COMPANY/DBA: 6 2s ADDRESS:,,, PERMIT APPLICATION IS FOR: (v�NEW INSTALLATION ( ) ALTERATION ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description: lr�'a�y`'; �� Spy �D-• ���5^ G �S� Tax Parcel Number: /`/ o2 g2D- ec Lot Size: /U 4,.Rs,, Physical Address: BUILDING TYPE: (Check (L-)--Residential/Single Family ( ) Residential/Multi-Family* ( ) Commercial/Industrial* Number of Bedrooms Number of Bedrooms Type TYPE OF WATER SUPPLY: (Check applicable category) ( ) Well ( ) Spring ( ) Surface (� Public Name of Supplier: Tou.,e, o-1 64pjL v— *These systems require design by a Registered Professional Engineer SIGNATURE: �r��� ,��J Date: Z �S ,o ****************************************************************** ******** AMOUNT PAID: )C) . CSZ) RECEIPT #:. I F�r��I CO DATE: CHECK #: CASHIER. FED EAGLE COUNTY COMMUNITY DEVELOPMENT COMMUNITY DEVLOP.MENT DEPARTMENT (303) 328-8730 EAGLE COUNTY, COLORADO July 14, 1994 George and Dana Gerard P.O. Box 532 Eagle, CO 81631 500 BROADWAY P.O. BOX 179 EAGLE, COLORADO 81631 FAX: (303) 328-7185 RE: Final of ISDS Permit No. 1347-94 Parcel #2111-202-001-006 Property located at: 251 Daggett Lane, Gypsum Dear Mr. and Mrs. Gerard This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your dwelling may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at 328-8755. Sincerely, Shannon Garton Environmental Health Specialist ENCL: Information Brochure Final ISDS Permit cc: files COMMUNITY DEVLOPMENT DEPARTMENT (303) 328-8730 DATE: TO: FROM: RE: 500 BROADWAY P.O. BOX 179 EAGLE, COLORADO 81631 FAX: (303) 328-7185 EAGLE COUNTY, COLORADO May 5, 1994 High Country Builders of Gypsum Environmental Health Division Issuance of Individual Sewage Disposal System Permit No.1347, Tax Parcel # 2111-202-00-006 Property Located at: 251 Daggett Ln., Gypsum Enclosed is your ISDS Permit No. 1347 is valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Please call our office well in advance for the final inspection. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County does not perform final inspections on engineer designed systems. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. If you have any questions, please feel free to contact Tania M. Busch -Weak at 328-8755. cc: files CbenONorthern, Inc. November 9, 1993 MAY 0 21994 Consulting Engineers and Scientists 5080 Road 154 Glenwood Springs, Colorado 81601 303 945-7458 303 945-2363 Facsimile Mr. Andy Gerard o 34t-'_ COUNTY c/o Johnson -Kunkel, Inc. COMMUNITY DEVELOPMENT P.O. Box 409 Eagle, Colorado 81631 Subject: Subsoil Study for Foundation Design, Proposed Residence, Dagget Lane, Eagle County, Colorado Job No. 4 566 93 Dear Mr. Gerard: As requested, Chen -Northern, Inc., performed a subsoil study for design of foundations at the subject site. The study was conducted in accordance with our agreement for geotechnical engineering services, to you, dated September 17,1993. The study was initiated based on verbal authorization from Roger Meyer of Johnson -Kunkel, Inc. The data obtained and our recommendations based on the proposed construction and subsurface conditions encountered are presented in this report. Proposed Construction: The proposed residence will be a single story wood framed structure with a partial basement located on the site near the test pits shown on Fig. 1. Ground floor will be either slab -on -grade or structurally supported over crawl space. Cut depths of about 4 to 8 feet are assumed. ;Foundation loadings for this type of construction are, assumed to be relatively light. If building conditions or foundation loadings are significantly different from those.described above, we should be notified "to reevaluate the recommendations presented in this report. Site -Conditions: The building site is presently a relatively flat hay field, with irrigation ditches along the east and south sides. The field had been recently mowed. Dagget Lane runs along the north side of the field. The site slopes gently down to the northwest with approximately a 1 foot drop in elevation across the building area. Subsurface Conditions: The subsurface conditions at the site were evaluated by excavating 2 exploratory pits at the locations shown on Fig. 1. The logs of the pits are presented on Fig. 2. The subsoils encountered, below about 1 foot of topsoil, consist of slightly sandy.:.,. silty clay.' Results of swell -consolidation tests performed on relatively undisturbed samples of the silty clay_ indicate moderate to.high compressibility_ under light to moderate surcharge and no expansion'potential when_ wetted under constant light surcharge'. No free water was observed in the pits at the time of excavation. Foundation Recommendations: Considering thesubsoils encountered in the exploratory pit and the nature of the proposed construction, we recommend spread footings placed on the undisturbed natural soil designed for an allowable soil bearing pressure of 800 psf for A memnar of the �H� nroi in of rmmnnnias Mr. Andy Gerard November 9, 1993 Page 2 support of the proposed residence. As an alternative, to achieve a lower settlement risk, the clay soils can be over -excavated to a depth of at least 3 feet below footings and replaced as compacted structural fill. The structural fill should extend laterally beyond the edges of the footings a distance at least equal to the depth of fill below the footings. Structural fill should be compacted to 98% of standard Proctor density at a moisture. content near optimum. Footings placed on compacted fill, as discussed above, can be designed for an allowable bearing pressure of 1500 psf. Footings should be a minimum width of 16 inches for continuous walls and 2 feet for columns. Loose and disturbed soils and existing fill encountered at the foundation bearing level within the excavation should be removed and the footings extended down to adequate natural bearing material. Exterior footings should be provided with adequate cover above their bearing elevations for frost protection. Placement of footings at least 42 inches below the exterior grade is typically used in this area. Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 12 feet. Foundation walls acting as retaining structures should be designed to resist a lateral earth pressure based on an equivalent fluid unit weight of 55 pcf. Floor Slabs: The natural on -site soils, exclusive of topsoil, can be used to support lightly to moderately loaded slab -on -grade construction. There is a risk of settlement of the silty clay soils. Removal and replacement of these soils compacted as discussed above could be done to reduce settlement potential. To reduce the effects of some differential movement, floor slabs should be separated from all bearing walls and columns with expansion joints which allow unrestrained vertical movement. Floor slab control joints should be used to reduce damage due to shrinkage cracking. The requirements for joint spacing and slab reinforcement should be established by the designer based on experience and the intended slab use. A minimum 4-inch layer of free -draining gravel should be placed beneath basement level slabs to facilitate drainage. This material should consist of minus 2-inch aggregate with less than 50% passing the No. 4 sieve and less than 2% passing the No. 200 sieve. All fill materials for support of floor slabs should be compacted to at least 95% of maximum standard- Piocfor-density at a moisture content near optimum. Required fill can consist of the on -site silty .clays devoid of vegetation and topsoil. Underdrain System: Although free water was not encountered during our exploration, it has been our experience in. mountainous areas that local perched groundwater may develop during times of heavy precipitation or seasonal runoff. ,Frozen ground during spring runoff can create a perched condition. We recommend below grade construction, such as retaining walls, crawl space and basement areas, be protected from wetting and hydrostatic pressure buildup by an underdrain system. ChenONorthern, Inc. Consulting Engineers ana Scientists Mr. Andy Gerard ;r November 9, 1993 Page 3 The drains should consist of drainpipe. placed in the bottom of the wall backfill surrounded above the invert level with free -draining granular material. The drain should be placed at each level of excavation and at least 1 foot below lowest adjacent finish grade and sloped at a minimum 1% to a suitable gravity outlet. Free -draining granular material used in the underdrain system should contain less than 2% passing the No. 200 sieve, less than 50% passing the No. 4 sieve and have a maximum size of 2 inches. The drain gravel backfill should be at least 2 feet deep. Surface Drainage: The following drainage precautions should be observed during construction and maintained at all times after the residence has been completed: 1) Inundation of the foundation excavations and under slab areas should be avoided during construction. 2) Exterior backfill should be adjusted to near optimum moisture and compacted to at least 95% of the maximum standard Proctor density in pavement and slab areas and to at least 90% of the maximum standard Proctor density in landscape areas. Free - draining wall backfill should be capped with about 2 feet of the on -site, finer graded soils to reduce surface water infiltration. 3) The ground surface surrounding the exterior of the building should be sloped to drain away from the foundation in all directions. We recommend a minimum slope of 12 inches in the first 10 feet in unpaved areas and a minimum slope of 3 inches in the first 10 feet in pavement and walkway areas. 4) Roof downspouts and drains should discharge well beyond the limits of all backfill. Percolation Testing Percolation testing was performed in the proposed leach field area west of the proposed building site. One profile pit had been excavated with a backhoe to a depth of 9 feet. The soils encountered in the profile pit consist of one foot of organic silty clay. overlying soft to stiff silty clay to the full depth of exploration. No free water was observed in the profile pit. Percolation testing was performed in three hand dug holes located as shown on Fig. 1. The pits were soaked the day before our testing. The results of the percolation testing are presented in Table II. The results indicate the subsoils have a variable percolation rate but should be acceptable for a conventional infiltration septic disposal system. Limitations: This report has been prepared in accordance with generally accepted soil and foundation engineering practices in this area for use by the client for design purposes. The conclusions and recommendations submitted in this report are based upon the data obtained .from the exploratory pits excavated at the locations indicated on Fig. 1 and the proposed type- of construction. -The nature and extent of subsurface variations across the site may not Y Chen ONnrthPrn 1nr Mr. Andy Gerard ;} November 9, 1993 Page 4 become evident until further excavation is performed. If during construction, fill, soil, rock or water conditions appear to be different from those described herein, this office should be advised at once so- reevaluation of the recommendations may be made. We recommend on -site observation of excavations and foundation bearing strata and testing of structural fill by a representative of the soil engineer. Sincerely, CHEN-NORTHERN, INC. 6;Fred R. Cameron Project Geologist Reviewed By moo`° o As ,q, Thomas L. Allen,P.E. �W?OX"ssi0.... Engineering Manager���1/lm��������\,;��� Attachments DAGGET LANE PtA 17 I I . APPROXIMATE SCALE 1• = 50.1 cu CU J Q 0 I — � PERC 1 PERC 2 Q_ - PIT 1 � ■ PROFILE PIT PERC 3 Q PIT 2 PIT 1 PIT 2 PROFILE PIT 100 100 WC = 24 95 DD=96 WC=18 95 -200 = 91. DD - 97 WC = 28 WC = 24 - --- --- - DD-= 91 - DD = 94 . -200 97 i- F- 90 90 I O O F F= w 85 85 w PTOPSOIL, Silty Clay, soft, very moist, black. FCLAY (CL); silty, sandy, soft to stiff, very moist, mixed brown, slightly calcareous. �9 Hand drive sample. NOTESi 1. Exploratory pits were excavated on September 20, 1993 with a rubber —tired backhoe. 2. Locations of exploratory pits were measured approximately by pacing from features shown on site plan. 3. Elevations of exploratory pits were not measured and logs .of exploratory pits are drawn to depth. 4. The exploratory pit locations and elevations should be considered accurate only to the degree implied by the method used. 5. The lines between materials shown on the exploratory pit logs represent the approximate boundaries between material types and transitions may be gradual. 6. No free water was encountered in the pits at the time and under the conditions Indicated. Fluctuations In water level may occur with time. 7. -LABORATORY TESTING RESULTS: WC=Water Content (7.) DD=Dry Density (pcf) —200=Percentage passing No. 200 sieve { 4 566 93 I Chen0Northern, Inc LEGEND AND NOTES ' rig. 3 N Zro- 1 C 0 2 N N a 0 3 0 U I 4 4 E1111111IM111, Moisture Content 18 percent Sampleol: Silty clay No movement upon wetting -7 ;: —him IIflY IIII■�11111�■�■ O.1 1.0 IV 1VV APPLIED PRESSURE — ksf Moisture Content = 24 percent Dry Unit Weight = 94 pcf Sample of: Silty Clay From: Pit 2 @ 6 feet APPLIED PRESSURE — ksf 4 566 93 C11eI1ONOT�lerh,IriG SWELL -CONSOLIDATION TEST RESULTS Fig. 4 0- x 1 Id lu 611 0 ` 2 5 M E1111111IM111:1Moisture Content 24 percent Dry Unit Weight 96 pcf Sample of: 111 I IIII ElIPJ111111Lilk■111111 III No movement upon wetting �III��I��III ■ �mn■eimu��ui 4 566 93 Chen NOittleri"1,IiiG SWELL -CONSOLIDATION TEST RESULTS Fig. 5 MSmSm 11111111110 IIIIIIIIII�11111111 F+ ►+ ►+ Fr ►+ F+ F+ F+ M+ M+ 1� F+ F� F+ Y F+ 1.+ 1.+ F+ F+ F+ 1.+ Fr N N N N N N N N N N N N N N N N N N N N N N N N W N N N N N N N ►+ N N O W W- O W N b N N 00 N N - V W W .O W O ld %O N %0 W N 00 N N W N W N W W !J u N bi N N N ►+ N ►+ W to O •W N %D - ba N 00 N 00 W ►+ W ►+ W O u W O N b u lJ b N �O N 00 W F+ wKi 1347-94 - Parcel #2111-202-00-006 JOB NAME 251 Daggett Lane GERARD JOB NO. JOB LOCATION BILL TO DATE STARTED DATE COMPLETED DATE BILLED AAC %Nii KTG G�7/0� \ c1?� � �/r � �-!il l,•t-� ii✓-P Gv0'vt L� IOW S / i` ' � �' wa x r / F C t"/ f G < /(O S/ .41 1, / c`! 'T 4/ W - f A kGZ !r Gr /a I JOB COST SUMM Y TOTAL SELLING PRICE [ fig /�i F / C� � I Q � � �s ���. , �� �i � Cl OTAL MATERIAL TOTAL LABOR INSURANCE SALES TAX MISC. COSTS TOTAL JOB COST GROSS PROFIT LESS OVERHEAD COSTS OF SELLING PRICE NET PROFIT JOB FOLDER Product 278 ®p NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MA 01471 F- i ` Zi JOB FOLDER J Printed in U.S.A. i