Loading...
HomeMy WebLinkAbout276 Milburn Ct - 239122307011 - 1180-92ISINDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH P.O. Box 179 - 550 Broadway • Eagle, Colorado 81631 Telephone: 328-7311 or 949-5257 or 927-3823 YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT. NO. 118`0 "92 Please call for final inspection before covering any portion of installed system. OWNER: Chip & Marie Mundav PHONE: 925-8747 MAILING ADDRESS: 212 Free Silver Court, Aspen, Co 81611 AGENT: PHONE: SYSTEM LOCATION: 0276 Milburn n o lYCarbondaleOak Ridge iTT, Tot 25 LICENSED INSTALLER: _ W 4� i71� .4-VO fr ✓ lci LICENSE N0. 5 �� DESIGN ENGINEER OF SYSTEM: Nigh C;olintrV Engineering INSTALLATION IS HEREBY GRANTED FOR THE FOLLOWING: 1000 GALLON SEPTIC TANK OR GALLON AERATED TREATMENT UNIT. DISPERSAL AREA REQUIREMENTS: 906 SQUARE FEET OF SEEPAGE BED SQUARE FEET OF TRENCH BOTTOM. SPECIAL REQUIREMENTS: 25 Infiltrator units in trenches, Eagle County recommends the use of a T distribution instead of a distribution bnx Install as per engineer design, ENVIRONMENTAL HEALTH OFFICER: DATE: CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10.104, C.R.S. 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. SECTION Ill, 3.21 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED ACCORDING TO THE REGULATIONS. FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: �"� ( SQUARE F/E"ET. %' "�"� �"� r • � -'S INSTALLED SEPTIC TANK: Y ��� GALLONS DEGREES FEET SEPTIC TANK CLEANOUT TO WITHIN 8" OF FINAL GRADE, OR: i PROPER MATERIALSAND ASSEMBLY x YES NO COMPLIANCE WITH COUNTY/STATE REGULATION REQUIREMENTS: X YES NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. COMMENTS: ENVIRONMENTAL HEALTH OFFICER: DATE: ENVIRONMENTAL HEALTH OFFICER: DATE: (RE-INSPECTIOtIESSARY) RETAIN WITH RECEIPT RECORDS PERMIT APPLICANT/AGENT: OWNER: AMOUNT PAID: RECEIPT R: CHECK N: CASHIER: INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT dr EAGLE COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH . i P.O. Box 179 - 550 Broadway • Eagle,_ Colorado 81631 Telephone: 32Attrivtu 7 or 927-3823 YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1 18 O —92 Please call for final inspection before covering any nnrtlnn of Inntnl6�iscw.�. OWNER:..Chil2 & Marie Munday II`` PHONE:_925-8747 ERG MAILING ADDRESS: egMMUNITY DEVELOPMENT AGENT: PHONE: SYSTEM LOCATION: 0276 Milburn Col,rt, Carbondale Oak Ridge ITT, T.nt 29 LICENSED INSTALLER: LICENSE NO. DESIGN ENGINEER OF SYSTEM: High Country Engineering INSTALLATION IS HEREBY GRANTED FOR THE FOLLOWING: 1000 GALLON SEPTIC TANK OR GALLON AERATED TREATMENT UNIT. � r DISPERSAL AREA REQUIREMENTS: 906 SQUARE FEET OF SEEPAGE BED SQUARE FEET OF TRENCH BOTTOM.. l 7 SPECIAL REQUIREMENTS: 25_ Infiltrator units in trenches. Eagl p O n y r rmmends theOf a T distribution instead Of a distribution bnsr Install as Per engineer design - ENVIRONMENTAL HEALTH OFFICER: `7-^`��—`J 1 DATE: CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED /N 25.10-104, C.R.S. 1973, AS AMENDED. 2. THIS PERMIT /S VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. SECTION III, 3.21 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED ACCORDING TO THE REGULATIONS. FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR$ NO SYSTEM SHALL BE DEEMED TO BE IN COMLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. MST ABSC PTiON OR DISPERSAL AREA: SQUARE FEET. INSTALLED SEPTIC TANK: GALLONS DEGREES FEET SEPTIC TANK CLEANOUT TO WITHIN 8" OF FINAL GRADE, OR: PROPER MATERIALS ANDASSEMBLY YES NO COMPLIANCE WITH COUNTY/STATE REGULATION REQUIREMENTS: YES NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. COMMENTS: ENVIRONMENTAL HEALTH OFFICER: DATE: ENVIRONMENTAL HEALTH OFFICER: (RE -INSPECTION IF NECESSARY) DATE: APPLICANT/AGENT: RETAIN WITH RECEIPT RECORDS PERMIT OWNER: --e AMOUNT PAID: RECEIPT C CHECK M: CASHIER: ------------------------------------ ' SENT BY:EAGLE COUNTY ; 7- 7- 2 I2?0§ �73033287207_� 3039632552;# 5/ 5 92 IS175 Permit #_ (� Building Permit P — � APPLICATION POR INDIVIDUAL, SHWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE- EAGLE COUNTY P.O. BOX 179 EAGLE, CO 81631 328-8755/927-3823(Sasalt) PERMIT APPLICATION PEE (I$150.poPERCOLATION TEST PEE $200.00 PROPERTY OWNER: Chip and Marie Munday MAILING ADDRESS: 212 Free Silver Court PHONE: 925- 47 q �e LI ANT /CONTACT P'ERBt)N: Stasmore Construction 963-1958 � PHONE LICENSED SYSTEMS CONTRACTORHigh Country Engineering �: DDRESS: Glenwood Springs CO PHONE: 945-8676 PERMIT APPLICATION IS FOR: (X) NEW INSTALLATION ( ) ALTERATION ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description: Oak Ridge III, Lot #25, 0276 Milburn Court, Carb. Parcel Number: Lot #25 :9 39 / 09307DII Lot sire: Physical Address: 0276 Milburn Court, Carbondale, Co 81623 BUILDING TYPE: (Check applicable category) ( I Residential / Single Family Number of Badrooms ( ) Residential / Multi -Family* Number of Bedrooms ( ) Commercial / Industrial* Type TYPE OF WATER SUPPLY: wall (X) Spring ( ) Surface ( ) Public ( ) Name of Supplier;...__.. *These systems require design by a Registered Professional, Engineer NOTE SITE PLAN MUST BE ATTACHED TO APPLICATION MAKE ALL REMITTANCE PAYABLE TO: 11EAOLE COUNTY TREASURER" SIGNATURE: DATE: J 1. 0 G AMOUNT PAID:_/.5_0 — - RECEIPT# ��� DATE: CHECK # 7 7� CASHIER:_ 1-4 V COMMUNITY DEVELOPMENT DEPARTMENT (303) 328-8730 EAGLE COUNTY, COLORADO July 24, 1992 J.W. Earthmovina Ent., Inc. Joe Weinries 1470 Snowmass Creek Road Snowmass, CO 81654 RE: Issuance of Individual Sewage Disposal System Permit No.: 1180-92 Dear Applicant: 500 BROADWAY P.O. BOX 179 EAGLE, COLORADO 81631 FAX (303) 328-7207 Enclosed is your ISDS Permit No. 1180-92 valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Please call our office well in advance for the final inspection. The final inspection is to be done before any portion of the installed system is covered. The deadline for the final inspections done by Eagle County Environmental Health is December 1. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County does not perform final inspections on engineer designed systems. Be aware that the specifications on the permit are minimum requirements only. Installers should bring this to the attention of the property owner. This permit does not indicate conformance with other Eagle county requirements. If you have any questions, please feel free to contact us at 328-8755. Sincerely, /�%� v�� �--,.�iv"/'o Brenda Henderson ✓ j Environmental Health, Administrative Assistant y RECEIVED AUG 31 1992 EAGLE COUNTY COMMUNITY DEVELOPMENT August 28, 1992 Roger Boyd Eagle County Community Development P.O. Box 179 Eagle, CO 81631 Re: Lot 25, Oak Ridge III, 0276 Milburn Court, Aspen Mountain View Subdivision Munday Residence ISDS HCE File No. 92004.14 Dear Roger: On August 20, 1992, High Country Engineering personnel observed the visible construction of the individual sewage disposal system at the above noted site. The construction appeared to be in conformance with the intent of the design. If you have any questions, please feel free to call. Sincerely, HIGH COUNTRY ENGINEERING, INC. TiP. Beck, P.E. PEngineer TPB:cso cc: Stasmore, Inc. 923 Cooper Avenue Glenwood Springs, CO 81601 Telephone: 303-945-8676 303-920-3669 • FAX: 303-945-2555 Memo to the file RE: ISDS #1180 installation Apparently the system contractor indicated on the ISDS permit application was changed after the permit for construction was issued. J.W. Earthmoving (the original contractor) and the general contractor (Statsmore Construction) neglected to inform the county of this change. In addition, Bogue construction continued to install a system without a permit in possession. Scott Bogue was contacted Jan. 14, 93, and the regulation regarding "permit in hand before installation" was reviewed for him. He was told that this time there would be no action taken towards his company, but that next time there would be consequences if he chose to ignore regulations. The home owner (Chip Munday) was also apprised of the situation on Jan. 14, 1993. 1180-92 - Parcel #239122307022, Oak Ridge III Lot 25, 0276 Milburn Court, Carbondale j� �/) ' r 1 Chip & Marie Munday.�(� NO. _](IR I nt-ATtnN BILL TO DATE STARTED DATE COMPLETED DATE BILLED � t rd Ra, LL8jw- Enq�2��� JOB COST SUMMARY TOTAL SELLING PRICE TOTAL MATERIAL TOTAL LABOR INSURANCE SALES TAX MISC. COSTS TOTAL JOB COST GROSS PROFIT LESS OVERHEAD COSTS % OF SELLING PRICE NET PROFIT JOB FOLDER Product 277 �pp NEW ENGLAND BUSINESS SERVICE INC., GROTON, MASS. 01471 JOB FOLDER Printed in U.S.A. I. i LOT 26 NATURAL GROUND I � LOT 22 I 1 SITE PLAN TRENCH CROSS SECTION (T_YP.) N. T.S. IRATOR UNIT GRAPHIC SCALE 30 0 15 30 so LOT 24 _ -LQ-01 1 -1 N °`tee •P SOLID F ( IN FEET ) 1 inch = 30 ft 120 GENERAL ABSORPTION TRENCH NOTES 1. TRENCH LENGTH SHALL NOT EXCEED 100 FEET. 2 THE BOTTOM OF EACH TRENCH SHALL BE LEVEL. 3. DRAINAGE DITCHES ARE TO BE PROVIDED ABOVE TRENCHES, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 4. TRENCHES SHALL FOLLOW CONTOURS. off., AM CAP OVABL CUT HOLE IN TOP OF INFILTRATOR UNIT FOR INSTALLATION OF INSPECTION WELL PIPE LING )RATED PIPE INSPECTION WELL DETAIL N.T.S. VICINITY MAP I GENERAL NOTES ; 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE EAGLE COUNTY REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, I EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE -MENTIONED I REGULATIONS.- f 2. FLOW: BEDR0014S •2 PERSONS/BEDROOM +75 GALLONS/PERSON/DAY IS 450 GP -11�` VERAGE DAILY FLOW. _ DESIGN/MAXIMUM FLOW - 1.5• AVERAGE = 675 GPD SEPTIC TANK: MINIMUM TANK SIZE ACCORDING TO CDOH REGULATIONS , 00 G ONS. (, .FIELD SIZE: PER CDOH EQUATIONS: A Q = MAXIMUM FLOW 5 t =PERCOLATION RATE 45 A = 675-445 - 90 SQ. FT 5 PER CDOH MINIMUM REQUIREMENTS FOR USE OF INFILTRATOR" SYSTEMS I AREA REDUCTION =( 0. 5) • A - _ AREA REQUIRED = 0.5* 906 - 45� S0. FT. @ 18. 75 SO. FT. PER UNIT =/25 Utz ITS L� t 3. TOPSOIL: SOIL EXCAVATED FROM SITE ACCEPTABLE IF NO CLAY IS PRESENT. 4. VEHICULAR TRAFFIC IS PROHIBITED ON THE FIELD. I 5. CLEANOUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100 FEET ALONG THE HOUSE SEWER UP TO SEPTIC TANK. RECEIVED F � 6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN 1/2-FOOT OF FINAL GRADE. Ilt� 2 i2 7. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG _ AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. COMMUNITY DEVL-L�-;,; 8. PROVIDE POSITIVE DRAINAGE OF SURFACE WATER AWAY FROM AREA I USING DRAINAGE SWALES AS NECESSARY. C 9. PERCOLATION RATE BASED ON TEST PERFORMED BY HIGH COUNTRY ENGINEERING, INC. ENGINEERING, INC. ON JULY 15, 1992. _-10__CONTOURS ARE _APPROXIMATE =_AND =REPRESENT LAND FORM ONLY. SOURCE _IS_ A SALES MAP OF UNKNOWN ORIGIN. 2 ---- ----_ `- I k II j- f ` f I 1 { F i I i k NO. DATE REVISION BY E MUNDAY RESIDENCE CARBONDALE, COLORADO PAMDUAL SEWAGE DOPOSAL SYSTEM ; F LOT 25, OAK RIDGE III HGi couNTRY EE>�Na NYC. ASPEN MOUNTAIN VIEW I 923 COOPER AVENUE CLayyyOOD 8PFgM CO 8W DES. TPB CK. FILE NO. SHEET 1 /14MUNDAY Q ) 945-8676 DR. HMS DATE 7/20/92 92004.14 OF 1