HomeMy WebLinkAbout264 Sunrise Ln - 239128403001 - 1179-92IS (2)INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH
P.O. Box 179 - 550 Broadway • Eagle, Colorado 81631
Telephone: 328-7311 or 949-5257 or 927-3823
YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 11'M 92
Please call for final inspection before covering any portion of installed system.
OWNER: C-balmers Morse PHONE: 963-1958
MAILINGADDRESS: 19218 Hwy 82 Suite 201, Carb9ndsig
AGENT: Laur-ate gat Cb.22 ers PHONE:_963-1958
SYSTEMLOCATION: 0264 Sunrise Lane, El Jebel
LICENSED INSTALLER: Gurule Excavation LICENSE NO. 2-92
DESIGN ENGINEER OF SYSTEM:
INSTALLATION IS HEREBY GRANTED FOR THE FOLLOWING:
12.50 GALLON SEPTIC TANK OR GALLON AERATED TREATMENT UNIT.
DISPERSAL AREA REQUIREMENTS:
3 SQUARE FEET OF SEEPAGE BED " SQUARE FEET OF TRENCH BOTTOM.
SPECIAL REQUIREMENTS: 31 infliltiators in trenches or 380 ft SB2 in trenches
Install inspection portals at end of each trench
ENVIRONMENTAL HEALTH OFFICER: �JUA041)4DATE: -7�lJ`[� ?C
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM
REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25.10-104, C.R.S. 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND
BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH
LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. SECTION 111, 3.21 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM
TO BE LICENSED ACCORDING TO THE REGULATIONS.
FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED'
PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: SSdUgRE FEET.
INSTALLED SEPTIC TANK:02O� GALLONS DEGREES FEET
SEPTIC TANK CLEANOUT TO WITHIN 8" OF FINAL GRADE, OR:
PROPER MATERIALS ANDASSEMBLY YES NO
COMPLIANCE WITH COUNTY/STATE REGULATION REQUIREMENTS: YES NO
ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED.
COMMENTS:
ENVIRONMENTAL HEALTH OFFICER: DATE: AAA
ENVIRONMENTAL HEALTH OFFICER: DATE:
(RE -INSPECTION IF NECESSARY)
RETAIN WITH RECEIPT RECORDS PERMIT
APPLICANT/AGENT:
OWNER:
AMOUNT PAID: RECEIPT #: CHECK #: CASHIER:
SENT SY:EAGLE COUNTY ; 7- 7-92 ; 12:03 ; 3033287207-� 3039632552;# 5/ 5
J 11 ._ 2 2 1,222 ISDS Permit #-477
•�Yg �1 Building Permit #
r
. r��., tlTS;' dl'rF3i�i!T
APPLICATION Fb �? ND IWAtid'-.`'9�i�� `..�ik'6 DISPOSAL SYSTEM PERMIT 0 o 2
ENVIRONMENTAL HEALTH OFFICE^ EAGLE COUNTY iJv+
P.O. BOX 179 +iv
EAGLE, CO 81631
328-8755/927-3823(Basalt)
PERMIT APPLICATION FEE $1S0.00 PEPRpq�ATION TEST PEE $200.00
PROPERTY OWNER: Chalmers Morse
MAILING ADDRESS: 19218 Hwy 82 Suite 201 963-1958
PHONE.
APPLICANT/CONTACT PERSON: Laura, Pat, Chalmers PHONE: same -)
LICENSED SYSTEMS CONTRACTOR: n
ADDRESS: P.O. Box 1383, Carbondale, CO 876-5466
PHONE:
PERMIT APPLICATION IS FOR: �X) NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Legal Descri.ption:0264 Sunrise Lane, E1 Jebel, Lot 1, Soderberg 1
,�239/-a�/-OS-005
Parcel Number: Soderberg filing 1
Lot size: `�.,x
Physical Address: 0264 Sunrise Lane, El Jebel
BUILDING TYPE: (Check applicable category)
( Residential / Single Family Number of Bedrooms
( ) Residential / Multi -Family* Number of Bedrooms
( ) Commercial / Industrial* Type
TYPE Off' WATER SUPPLY: Well(X) Spring ( ) Surface { )
Public ( ) Name of Supplier:�...
*These systems requires design by a Registered Professional Engineer
NOTE: SITE PLAN MUST BE ATTACHED TO APPLICATION
MAKE ALL R1114 C PAY TO: "EAGLE COUNTY TREASURER"
T
SIGNATURE:Pat Costello DATE: July 20, 1992
AMOUNT PAID: Lo U U RECEXPT# DATE:
CHECK . % . CASHIER:
COMMUNITY DEVELOPMENT
DEPARTMENT
(303) 328.8730
EAGLE COUNTY, COLORADO
November 10, 1992
Chalmers Morse
19218 Hwy 82
Suite 201
Carbondale, CO 81623
RE: Final of ISDS Permit No. 1179-92
500 BROADWAY
P.O. BOX 179
EAGLE. COLORADO 81631
FAX (303) 328.7207
This letter is to inform you that the above referenced ISDS
Permit has been inspected and finalized. Enclosed is a copy to
retain for your records. This permit does not indicate
compliance with any other Eagle County requirements. Also
enclosed is a brochure regarding the care of your septic system.
Be aware that later changes to your dwelling may require
appropriate alterations of your septic system.
If you have any questions regarding this permit, please
contact the Eagle County Environmental Health Division at
328-8755.
Sincerely, �`
�,"Ujncto- C�
Brenda Henderson
Office Assistant
Environmental Health
/bh
ENCL: Information Brochure
Final ISDS Permit
COMMUNITY DEVELOPMENT
DEPARTMENT
(303) 328.8730
EAGLE COUNTY, COLORADO
July 29, 1992
Art Gurule Excavating
P.O. Box 13823
Carbondale, CO 81623
RE: Issuance of Individual Sewage Disposal System
Permit No.: 1179-92
Dear Applicant:
500 BROADWAY
P.O. BOX 179
EAGLE. COLORADO 81631
FAX (303) 328-7207
Enclosed is your ISDS Permit No. 1179-92 valid for 120 days.
The enclosed copy of the permit must be posted at the
installation site. Any changes in plans or specifications
invalidates the permit unless otherwise approved. Please call
our office well in advance for the final inspection. The final
inspection is to be done before any portion of the installed
system is covered. The deadline for the final inspections done
by Eagle County Environmental Health is December 1. Systems
designed by a Registered Professional Engineer must be certified
by the Engineer indicating that the system was installed as
specified. Eagle County does not perform final inspections on
engineer designed systems.
Be aware that the specifications on the permit are minimum
requirements only. Installers should bring this to the attention
of the property owner.
This permit does not indicate conformance with other Eagle
county requirements.
If you have any questions, please feel free to contact us at
328-8755.
Sincerely,
Brenda Henderson
Environmental Health, Administrative Assistant
cc: file
Building Department, File #3381
October 22, 1992
RECEIVED
OCT 2 3 1992
EAGLE COUNTY
COMMUNITY DEALOPMENT
Mr. Ray Merry
Eagle County Environmental Health
P.O. Box 179
Eagle, CO 81631
Re: ISDS at 0264 Sunrise Lane, El Jebel
HCE File No. 92004.21
Dear Ray:
On October 20, 1992, High Country Engineering, Inc. personnel observed the visible
construction of the individual sewage disposal system at 0264 Sunrise Lane above El Jebel. We
had previously prepared a letter with recommendedflows and sizing.
The construction appeared to conform to the recommended sizes, based on Eagle County
Regulations. Copies of an "as -built" drawing prepared by the contractor, as well as our original
letter are enclosed.
If you have any questions or comments, please feel free to call
Sincerely,
HIGH COUNTRY ENGINEERING, INC.
Ti othy P. Beck, P.E.
Pri cipal Engineer
TP /cso
cc: Stasmore
923 Cooper Avenue Glenwood Springs, CO 81601
Telephone:303-945-8676 FAX:303-945-2555
October 14, 1992
Stasmore, Inc.
P.O. Box 28369
E1 Jebel, CO 81628
Attn: Mike Plant
Re: Chalmers ISDS, O2.64 Sunrise Ln., El Jebel, CO
HCE File Number 92004.21
Dear Mr. Plant:
Per your request we have reviewed the previous ISDS permit for this
lot and revised the size to show the increase from a three bedroom
house to a five bedroom house. All data is based upon information
C from the previous permit (Eagle County Permit No. 985). The
percolation rate used was calculated from the area required on that
previous permit.
C
The pertinent data is as follows:
5 Bedrooms
Design Flow 1125 gal/day
Perc Rate 41 min/inch
Area Required for Std. Trench System 1440 sq. ft.
Area Required for Std. Bed System 1873 sq. ft.
Less 40% for using "Contactor" system 1124 sq. ft.
@ 16.7 sq. ft./unit, Units Required 67
Septic Tank 1500 gal. (minimum)
;i
923 Cooper Avenge Glenwood Springs, CO 81601
Telephone: 303.945-8676 303-920-3669 • FAX: 303-945-2555
Stasmore, Inc.
October 14, 1992
Page 2
If you have any questions, or need additional information, please
call.
Sincerely,
HIGH COUNTRY ENGINEERING, INC.
Ti othy P. Beck, P.E.
Pri cipal Engineer
TPB/soe
encl.
Job Title S IP'SM /CAW L%44R4 Job No. U02-I
by -� date ck'd by date 0
Subject---/Si�S page ---Z- of
923 Cooper Avenue - Glenwood Springs, CO 81601
Telephone: 303-945-8676 - 303-920-3669 - FAX: 303-945-2555
rtKUULATION TEST
ENVIRONMENTAL HEALTH DEPARTMENT
Eagle County
FEE: $125.00
OWNER:
LEGAL DESCRIPTION:
ISDS APPLICATION NO.
RURAL ADDRESS:
TYPE OF DWELLING:
NUMBER OF BEDROOMS• 3
DATE OF PERCOLATION TEST: //3/go TYPE OF SOIL:
TEST HOLES PRE-SOAKED: YES NO
e k r
spy
TIME
WATER DEPTH
II INCHES OF FALL
RATE
7
2
3
II 1
2
3
II 1
1 2
3
11
2
3
-�
—
= v
3 1
1,2
d
io
a = 35s
l� "3
/1 : 37
3 g
8
I y `FS
Y
y
�r r,
�vrr�'/
sz6 rrP/
N0 m
8
x
y
�/ ! tP/
/O �fP/
ar✓ rP I
�� ►,
If
3
r
S
g
g
Y,[.,�/
ye,
,,0^o�J
PERCOLATION RATE: yo /4'7/0/
RECOMMENDED MINIMUM SEPTIC TANK SIZE: /006ti-
RECOMMENDED MINIMUM F�E-L- g6-0 FQ
1
RECOMMENDED MINIMUM SQUARE FOOTAGE PER BEDROOM:'
SITE HAS BEEN REVIEWED AND TESTED FOR PERCOLATION RATE.
_ -7 9e"
Environments ealth Officer Date
rnmmCKITC
w�
�FM1�
*
II
fowl .
4'}
r
'
I
i