Loading...
HomeMy WebLinkAbout325 Milburn Ct - 239122307002 - 1150-92ISINDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH P.O. Box 179 - 550 Broadway • Eagle, Colorado 81631 Telephone: 328-7311 or 949-5257 or 927-3823 YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE, PERMIT NO. 1 1 50-92 Please call for final inspection before covering any portion of installed system. OWNER: Friederich Luckhof PHONE: 963-1106 MAILING ADDRESS:-' 0 9 6 Kings Row, Carbondale CO 81623 AGENT: PHONE: SYSTEM LOCATION: 1096 Kings Row, Carbondale CO 81623 LICENSED INSTALLER: Richard McClellan LICENSE NO. 27-92 DESIGN ENGINEER OF SYSTEM: INSTALLATION IS HEREBY GRANTED FOR THE FOLLOWING: 1000 GALLON SEPTIC TANK OR GALLON AERATED TREATMENT UNIT. DISPERSAL AREA REQUIREMENTS: 750 SQUARE FEET OF SEEPAGE BED SQUARE FEET OF TRENCH BOTTOM. SPECIAL REQUIREMENTS: 20 Infiltrators in trenches Or 250 ft Of 10" SB2 in trenches. Permit valid only upon engineer review and certification, see attachment for engineer review requirements. ENVIRONMENTAL HEALTH OFFICER: DATE: CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, C.R.S. 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. SECTION Ill, 3.21 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED ACCORDING TO THE REGULATIONS. FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM /S APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. �] INSTALLED ABSORPTION OR DISPERSAL AREA: SQUARE FEET. V )' a a / INSTALLED SEPTIC TANK: % 000 GALLONS DEGREES FEET SEPTIC TANK CLEANOUT TO WITHIN 8" OF FINAL GRADE, OR: PROPER MATERIALSAND ASSEMBLY YES NO COMPLIANCE WITH COUNTY/STATE REGULATION REQUIREMENTS: YES NO ANY ITEM CHECKED yN�O�REQUIRES rCORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. COMMENTS: 61r/`- lx_ tliQnQAX .7ZX_.1.�l _t0 ENVIRONMENTAL HEALTH OFFICER: �L lam/ l l LL DATE: ENVIRONMENTAL HEALTH OFFICER: DATE: (RE -INSPECTION IF NECESSARY) RETAIN WITH RECEIPT RECORDS PERMIT APPLICANT/AGENT: OWNER: AMOUNT PAID: RECEIPT #: CHECK #: CASHIER: n1JlN.L-LUaL1QnS Will NOT Be Accepted (Site Plan MUST be attached) ISDS Permit ## Building Permit APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. 0. BOX 179 EAGLE, CO 81631 328-81-55/927-3823 (Basalt) * PERMIT APPLICATION FEE $150.00 * PERCOLATION TEST FEE $125.00 * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" PROPERTY OWNER �i'.►a �lP,r�r/. 1, oI_ %� sI) MAILING ADDRESS! ® @tt� t DQ r�6 PHONE: APPLICANT/CONTACT PERSON: �� r PHONE: LICENSED SYSTEMS CONTRACTOR: ��/� ��µ �� / _ PHONE: �-� �01/ COMPANY/DBA : ° �a lIi1C. ADDRESS: 7! OZOX *xcx********* *** * * * * * * * * * * * * PERMIT APPLICATION IS FOR: (,C) NEW INSTALLATION LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEMLTERATION ( ) REPAIR Legal Description: e. ��7 11 Lr� Tax Parcel Number: ! 2 0" Lot Size: Physical Address: BUILDING TYPE: (Check applicable category) (-) Residential/Single Family ( ) Residential/Multi-Family* Number o Bedrooms 57j ( } Commercial/Industrial* Number of Bedrooms Type ---- TYPE Off' WATER SUPPLY: ( ) Well ( ) (•k) Public Name *These systems require SIGNATURE: AMOUNT PAID TIME LOG: TRAVEL: (C' eck applicable category) Spring ( ) Surface Of Supplier:��� design by a Registered Professional Engineer * * * * * ��- Date: RECEIPT Y : �� DATE: CHECK : �. CASHIER: PERC: FINAL: RECEIVE® MAY 8 1992 COMA, EAGLE COUNTY fMPner., �:OMMLINITY DEVELOPMENT DEPARTMENT (303) 32S.3730 EAGLE COUNTY, COLORADO May 19, 1992 Enartech, Inc. P.O. Box 160 Glenwood Springs, CO 81602 RE: Issuance of Individual Sewage Disposal System Permit No.: 1150-92 Dear Applicant: 500 BROADWAY P.O. BOX 179 EAGLE. COLORADO S 1631 FAX (303) 3I.. ; 207 Enclosed is your ISDS Permit No. 1150-92 valid for 120 days. Tile enc-osed copy of the permit must be posted at the ynsEallation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Please call our office well in advance for the final inspection. The final inspection is to be done before any portion of the installed system is covered. The deadline for final inspections done by Eagle County Environmental Health is December 1. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County does not perform final inspections on engineer designed systems. Be aware that the specifications on the permit are minimum requirements only. Installers should bring this to the attention of the property owner. This permit does not indicate conformance with other Eagle County requirements. If you have any questions; please feel free to contact us at 328-8755. Sincerely.., Brenda He.iderson Environmental Health Administrative Assistant Encicsure cc: ISDS File Su-lding Department = 5287 COMMUNITY DEVELOPMENT DEPARTMENT (303) 328.8730 July 8, 1992 Friederich 1096 Kings Carbondale, EAGLE COUNTY, COLORADO Luckhof Row CO 81623 RE: Final of ISDS Permit No. 500 BROADWAY P.O. BOX 179 EAGLE, COLORADO 81631 FAX (303) 328.7207 This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your dwelling may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at 328-8755. Sincerely, n Brenda Henderson Office Assistant Environmental Health /bh ENCL: Information Brochure Final ISDS Permit cc: Files BP# 5287 ENVIRONMENTAL HEALTH ISDS PERMIT Permit #: 1150-92 Property Owner: Friederich Luckof Special Requirements: Due to slow perc rate use Trench system. Permit valid only upon engineer review and certification. 1. Registered Professional Engineer (RPE) must conduct site evaluation. 2. Certification letter must accompany permit. 3. RPE will be responsible for certifying that system has been properly installed and providing final site plan to Eagle County. COMMUNITY DEVELOPMENT DEPARTMENT (303) 32S-S'30 EAGLE COUNTY, COLORADO Dear I.S.D.S. Applicant: Your application for (ISDS) Permit for has been received. 300 BROADWAY F.O. BOX I ?9 EAGLE. COLORADO S 1631 FAX (303) 3iS-'207 an _Indio -dual Sewage Disposal System Issuance of your permit is on hold until the following materials or fee(s) are submitted. Payment of $150.00 Application Fee Payment of $125.00 Percolation Test Fee Site Plan Licensed System Contractor (See attached list) Engineers Design Other- If you have any questions please call, 328-8755. When calling or submitting information please reference your ISDS application # ! 1 lc)- 9,,Q Please submit information to: Eagle County Environmental Health Division P.O. Box 179 500 Broadway Eagle, CO 81631 ISDSHOLD.LET ISDSDSK BH392 Vr,rje,rich LuCKMI 1SUS PERMIT = %/ log6 Kn <V �b� PERCOLATION TEST J Gar �m^ v(NEAGLE COUNTY ENVIRONMENTAL HEALTH DEPT. �' j CO 116 L3 S L OWNER: Luck ,5 LEGAL DESCRIPTION: MAILING ADDRESS: 0325 TYPE OF DWELLING: NUMBER OF BEDROOMS 3 TEST HOLES PRE-SOAKED: YES \�— NO TTMF TJArn n nc+nmTT 1 2 3 J—, ;0. 75 A, 5 3' 1 2 3 1 21)(_ SU1L FROFI] 0 , G�� Dnic iapsai; `ussnc 40 2l. l r J, 7-516. 2_5 �, )5 0 a� - 21 Vey 40 3 5 ao 4 , /�375 /�.7� 5 /� 0 /0- 5 Q� 3. F7 115 /6. >5 �5 .125 0 �'G� �D — 6 �y,c" z 375 a � 1z5 /3, 3 ao ao' 7 , a 37-5, 133 r Time to drop last inch ��r 15 -'% 15-3.S+ PERC RATE: _Use 30 MINIMUM SEPTIC TANK SIZE: MINIMUM LEACH FIELD SIZE: Vqo COMMENTS : _� %,6/. �00/?�9soi/- / elr�r /�erP /5 9d/nc, DES �f+�irl/S/l���dYC. 0 r PERC TEST DONE BY: EnvWonmentalY Hea rev. 6/90ks Officer DATE: .5'4-qL Odl ENARTECH Inc. Consulting Engineers and Hydrologists May 26, 1992 Mr. Friederich Luckhof 1096 Kings Row Carbondale, CO 81623 RE: Eagle County Individual Sewage Disposal Permit No. 1150-92 Dear Mr. Luckhof: .!.,Y 2 7 1192 \\\� EAGLE COUINTY naA�,:!s,"'T`r' ORPLOPMENT AAWI IR 0 1 h� This letter is to provide the design review and certification for the individual sewage disposal system for your proposed residence located at 325 Milborn Court, which is Lot 16 of Aspen Mountain View, Oak Ridge III Subdivision, Filing 3, in Eagle County. ISDS Permit No. 1150-92 issued by Eagle County for this project is enclosed, along with the Special Requirements, Field Percolation Test Results, Design Calculations, Site Plan and Permit Application associated with this permit. I have reviewed the enclosed information and have inspected the project site, and hereby accept the design of proposed system as described in ISDS Permit No. 1150-92. The original Permit had the incorrect address for the system location; I revised the Permit to indicate the correct address. The system installation contractor must contact me for an inspection prior to backfilling the system, it would be best if he gives me as much prior notice as possible to avoid potential scheduling conflicts. If you have any questions, please give me a call. Sincerely, EMA RTEC14 T VC Peter Belau, P.E. PB/des Enclosures cc: Roger Boyd, Eagle County P342-03 (P342_02A)92 DESIGN CERTIFICATION •�����c;,p0 R Ecis 7 302 Eighth Street, Suite 325 P.O. Drawer 160 Glenwood Springs, Colorado 81602 (303) 945-2236 Chen@Northern, Inc. Consuihng Eip;neerr: and SCienllsts `080 Roao 154 G enwaod Springs. Colorado 81601 303945 7458 303 945-2363 Facs:mie November 15, 1991 Am Freidrich Iuckhof' 1096 Kings Row Carbondale 00 81623-9691 Subject: Observation of Excavation, Proposed Residence, Aspen Mountain View, Filing 3, Lot 16, Oak Ridge Subdivision, Milburn Court, Eagle County, Colorado. Job No. 4 145 92 Dear Mr. Iuckhof: As requested, Chen -Northern, Inc., observed the excavation at the subject site on November 5, 1991 to evaluate the soils exposed for foundation support. The findings of our work and recommendations for the foundation design are presented in this report. The work was done in accordance with our agreement for geotechnical engineering services to Freiderich Iuckhof, dated November 1, 1991. The proposed residence will be a two-story wood frame structure located on a southwesterly sloping hillside above Milburn Court. The lower level will be a walkout type basement partially of concrete construction with a slab -on -grade floor. The building has been designed to be supported with spread footings assuming an allowable soil bearing pressure of 1500 psf. At the time of our visit to the site, the foundation excavation had been cut in two levels from 1/2 to 8 feet below the adjacent ground surface. The materials exposed in the bottom of the excavation consisted primarily of relatively hard (calcareous) cemented "caliche" type soil. There were scene areas which were loose and disturbed due to the excavation process and loose man -placed fill, less than 1 foot deep, had been placed in the basement slab area. The results of a --r-A i.on ?nnlysis performed qn a sample of the caliche soils (minus 5-inch fraction) 6btained from the site, which had broken down as sandy gravel with cobbles, are presented on Fig. 1. No water was observed in the excavation and the exposed soils were slightly moist. Considering the conditions exposed in the excavation and the nature of the proposed construction, spread footings placed on the undisturbed natural caliche soils designed for an allowable soil bearing pressure of 1500 psf should be adequate for support of the proposed building. Footings should be a minimum width of 16 inches for continuous walls and 2 feet for columns. Areas of loose or soft material or existing fill encountered at the foundation bearing level within the excavation should be removed and the footings extended down to adequate natural bearing material. Exterior footings should be provided with adequate cover above their bearing elevations for frost protection. Continuous foundation walls should be reinforced top and bottom to span local ancmalies such as by assuming an unsupported length of at least 10 feet. Foundation walls ENARTECH Inc. Consulting Engineers and Hydrologist RECEIVED July 2, 1992 Mr. Roger Boyd Eagle County Environmental Health Dept. P.O. Box 179 Eagle, CO 81631 RE: ISDS Permit No. 1150-92 Fredrich Luckhof Residence Dear Roger: JUL 7 1992 CO —MIEN LE TV DEVELOPMENT \\\� % AN„` This letter is to certify that the Individual Sewage Disposal System for the Fredrich Luckhof residence located at 325 Milborn Court (Lot # 16, Oak Ridge III, Aspen Mountain View Subdivision) has been constructed in accordance with the requirements of ISDS Permit No. 1150-92. The system installation contractor installed 27 Contactor chambers in trenches rather than 20 Infiltrator chambers as specified. The number of chambers required is calculated as follows: (750 ft2 leach area) x (0.6)/16.7 ft2 per chamber = 27 Contactor chambers I inspected the system installation on June 30, 1992. Please give me a call if you have any questions. Sincerely, ENARTECH, INC. Peter Belau, P.E. PB/des cc: Fredrich Luckhof Rick McClelland, M & M Construction P342-03 (P342_03A)92 302 Eighth Street, Suite 325 P.O. Drawer 160 Glenwood Springs, Colorado 81602 (303) 945-2236 L"/W 0 %1117ir?aA- Size 000 C ��Sorh>/fin f/v��Gf 5 a� WO PI W lewd 74 / 3701 Z /9 "OBr � ,')-rw//Tr,. Tr.s /y1 /'/" C;jes Oi 71013 T12 pe, &/ dF /a 11sB2 �50 fl d' /4 " s32 le Qy Qi 11.JV-74 - raLce1 V ZJJ1-ZZa-U/-UUZ, Aspen Mnt View, Lot 16, Filing 3, 325 Milburn CT Carbondale, Friederich Luckhof JOB NO. 7 JOB LOCATION DATE STARTED DATE COMPLETED DATE BILLED ' � AS2 S4•+�C'DNi �7APSS /�i✓' � 5/ ti° �� T�5 Q I/�.c�M Cot'I �wc?L1 JOB COST SUMMARY TOTAL SELLING PRICE �/lCr ��cf7 L/JC. TOTAL MATERIAL TOTAL LABOR INSURANCE SALES TAX ie,k - IUD a �� S M ISC. COSTS rA0 V��i OV1 ►n rev Gn� CerT/"7i�•� 1/� S� a//�r�,tr►G.� ih le TOTAL JOB COST GROSS PROFIT 1133 LESS OVERHEAD COSTS % OF SELLING PRICE NET PROFIT JOB FOLDER Product 278 ®q NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MASS. 01471 JOB FOLDER Printed In U.S.A.