HomeMy WebLinkAbout160 Millburn Ct - 239122307012 - 1141-92ISINDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH
P.O. Box 179 - 550 Broadway • Eagle, Colorado 81631
Telephone: 328-7311 or 949-5257 or 927-3823
YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1 14,1 —92
Please call for final inspection before covering any portion of installed system.
OWNER: Shane & Sybrina Stevenson PHONE: 927-9459
MAILING ADDRESS: P.O. Box 8096 Aspen, CO 81612
AGENT: PHONE:
SYSTEM LOCATION: 0160 Milburn Court, Carbondale CO 81623
LICENSED INSTALLER: M & M Construction LICENSE NO. 097-99
DESIGN ENGINEER OF SYSTEM: High Country Engineering
INSTALLATION IS HEREBY GRANTED FOR THE FOLLOWING:
1250 GALLON SEPTIC TANK OR GALLON AERATED TREATMENT UNIT.
DISPERSAL AREA REQUIREMENTS:
SQUARE FEET OF SEEPAGE BED 19 10 SQUARE FEET OF TRENCH BOTTOM.
SPECIAL REQUIREMENTS: 724 Su. Ft of trench With Infiltrator units. Install per R.P.E.
design. Install inspection portals in each trench.
ENVIRONMENTAL HEALTH OFFICER: DATE:
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM
REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, C.R.S. 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND
BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND
BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH
LEGAL ACTION AND REVOCATION OF THE PERMIT,
3. SECTION Ill, 3.21 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM
TO BE LICENSED ACCORDING TO THE REGULATIONS.
FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED
PRIOR TO COVERING ANY PORTION OF THE SYSTEM. r
INSTALLED ABSORPTION ORS� DISPERSAL AREA: f � (`-' SQUARE FEET. Na�j? /+/��n.�Y',$
INSTALLED SEPTIC TANK: � // GALLONS DEGREES FEET
SEPTIC TANK CLEANOUT TO WITHIN 8" OF FINAL GRADE, OR:
PROPER MATERIALS AND ASSEMBLY YES NO
COMPLIANCE WITH COUNTY/STATE REGULATION REQUIREMENTS: YES NO
ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED.
COMMENTS: , STG�i/%Y1 //%/Sle"ll'es( QCCOIY /+2 /%F Lr%/l%/%Fo �- ' GpS� as
ENVIRONMENTAL HEALTH OFFICER:DATE: ✓ _ �y
ENVIRONMENTAL HEALTH OFFICER: DATE:
(RE -INSPECTION IF NECESSARY)
RETAIN WITH RECEIPT RECORDS PERMIT
APPLICANT/AGENT:
OWNER:
AMOUNT PAID: RECEIPT #: CHECK #: CASHIER:
wi7complete Applications Wil_ NOT Be Accepted
(,mite Plan MUST be attached)
ISDS Permit # / I
Building Permit
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY
P. 0. BOX 179
EAGLE, CO 81631
328-8755/9-7-3823 (Basalt)
• :Kkk kkkkkkkk:Kk:Kk;K kk:kkk•" kkk•.� kk::k !: :Kk:kk k;Kkku: kkk:Kk:KkkkkX kkkkkk A kk:K kkk:k kk•.k k:kkk:k
* PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $125.00 k
MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" k
::k .K .K :Kkkk ;Kkkkk kk kk kkkkkkk•.Kkkkkkkk:Kkkkkkkkkkkkk kkkk kkkk k'kkkkkkkK kkkkk:K :Kkkk•.k ;k
PR3PERTr OWNER: 5 �.ner -� Is
MAILINIG ADDRESS: �d. � gdc((p NCO '91 1,;L PHONE : ga l
APP7 ICANT/CONTACT PERSON: c,� �jiZ� (ilQ� C e,U 9�oYl PHONE: ��5� f
q`a
LICENSED SYSTEMS CONTRACTOR:k
—�- :� MC." PHONE:
COMPANY/DBA:WkEiGADDRESS:
vl k �( �( �: k k1 x %Kc'�V 1 •�.ki.c \V ► 1 k �k k X :�: x
^d
9:l' k Y: G l -e l uj co b*
`5-7173 Yl X;ckl/'V /"17l
PERMIT APPLICATION IS FOR: ) NEW INSTALLATION (., ) ALTERATION ( ) REPAIR
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: 31UO Z
Legal Description: L0_7'_,��p 6ak- ,C41-=
C .�Wvl ou5 (// -00i
Tax Parcel Num lr:"\�a3911 as 30r7 Cal a, Lot Size:
Physical Address: O/(�c0 ffl l huRP7 awz
BUILDING TYPE: (Check applicable category)
( Residential/Single Family
( ) Residential/Multi-Family'
( ) Commercial/Industrial*
TYPE OF WATER SUPPLY: ;Check applicable category)
( ) Well ( ) Spring urrace
( Publ_c Name of Supplier: 45/p /�QIc1
CAS
s AceE5
car,Jonala c, eo ff/�a 3
1
Number or Bedroo
Number of Bedrooms
Type
F
"'These systems require design by a Registered Professional Engineer
SIGNATURE: Date:
•.c �:�: X kk iKk•.k 'n •k A\' >' iKk kX'kXkk�: kk•.: kY: A kkkkYc irkkkkkkkkk�: kkkkk;kkk kk kkkkkkkk�c kkkkkkkkkY:
AMOUNT PAID: v �.��� �� RECEIPT DATE
CHECK CASHIER:`
TIME L3G : TRAVEL:
RECEIVED
APR 14 1992
PERC:
FINAL:
EAGLE COUNTY
COMMUNITY DEVELOPMENT
COMMUNITY DEVELOPMENT
DEPARTMENT
(303) 328-8730
EAGLE COUNTY, COLORADO
May 8, 1992
Shane as Sybrina Stevenson
P.O. Box 8096
Aspen, CO 81612
RE: Filial of ISDS Permit No. 1141-92
500 BROADWAY
P.O. BOX 179
EAGLE, COLORADO B 163 1
FAX (303) 32S.7207
This letter is to inform you that the above referenced ISDS
Permit has been inspected and finalized. Enclosed is a copy to
retain for your records. This permit does not indicate
compliance with any other Eagle County requirements. Also
enclosed is a brochure regarding the care of your septic system.
Be aware that later changes to your dwelling may require
appropriate alterations of your septic system.
If you have any questions regarding this permit please
contact the Eagle County Environmental Health Division at
328-8755.
Sincerely,
Brenda Henderson
Office Assistant
Environmental Health
/bh
ENCL: Information Brochure
Final ISDS Permit
ec: Files BP# 5270
COMMLINITY DEVELOPMENT
DEPARTMENT
(303) 32S-S730
EAGLE COUNTY, COLORADO
April 20, 1992
M & M Construction
P.O. Boy: 2299
Glenwood Springs, CO 51602
RE: Issuance of Individual Sewage Disposal System
Permit No.: 1141
Dear Applicant:
500 BROADWAY
P.O. BOX 179
EAGLE, COLORADO S 1631
FAX (303) 328.7207
Enclosed is your ISDS Permit No. 1141 valid for 120 days.
The enclosed copy of the permit must be posted at the
installation site. Any changes in plans or specifications
invalidates the permit unless otherwise approved. Please call
our office well in advance for the final inspection. The final
inspection is to be done before any portion of the installed
system is covered. The deadline for final inspections done by
Eagle County Environmental Health is December 1. Systems
designed by a Registered Professional Engineer must be certified
by the Engineer indicating that the system was installed as
specified. Eagle County does not perform final inspections on
engii:eer designed systems.
Be aware that the specifications on the permit are minimum
requirements only. Installers should bring this to the attention
of the property owner.
ISDS Permit 1141
Page 2
This permit does not indicate conformance with other Eagle
County requirements.
If you have any questions, please feel free to contact us at
328-8755.
Sincerely,
Br-enda Henderson
Environmental Health Administrative Assistant
Enclosure
cc: ISDS File
Building Department n 5270
April 30, 1992
Eagle County Community Development
P.O. Box 179
Eagle, Colorado 81631
Attn: Roger
REC�.i
EAGLE COU:
CC'.'iMUNITY DEUEL;,
Re: Lot 26, Oak Ridge III
Aspen Mountain View Subdivision, Filing 3
HCE Job No. 92004.01
Dear Roger:
On April 6, 1992, High Country Engineering, Inc. personnel
conducted a percolation test on Lot 26, Oak Ridge III, Aspen
Mountain View Subdivision, Filing 3.
The soil profile was as follows:
0-1 ft. black, clayey topsoil
1-4 ft. light brown clayey sandy silt with cobbles
4-8 ft. hard white silty formation
The average percolation rate was approximately 40 minutes per inch,
but we recommended a design rate of 45 minutes per inch.
On April 22, 1992, HCE personnel observed the visible construction
of the individual sewage disposal system at the Stevenson
residence. The construction appeared to be in conformance with the
intent of the design.
If you have any questions or need additional information, please
give us a call.
Sincerely,
HIGH COUNTRY ENGINEERING, INC.
Ii
thy P. Beck, P.E.
cipal Engineer
.cso
cc: Sybrina Stevenson
923 Cooper Avenue • Glenwood Springs, CO 81601
Telephone:303-945-8676 • FAX:303-945-2555
April 30, 1992
Eagle County Community Development
P.O. Box 179
Eagle, Colorado 81631
Attn: Roger
Re: Lot 26, Oak Ridge III
Aspen Mountain View Subdivision, Filing 3
HCE Job No. 92004.01
Dear Roger:
On April 6, 1992, High Country Engineering, Inc. personnel
conducted a percolation test on Lot 26, Oak Ridge III, Aspen
Mountain View Subdivision, Filing 3.
The soil profile was as follows:
0-1 ft. black, clayey topsoil
1-4 ft. light brown clayey sandy silt with cobbles
4-8 ft. hard white silty formation
The average percolation rate was approximately 40 minutes per inch,
but we recommended a design rate of 45 minutes per inch.
On April 22, 1992, HCE personnel observed the visible construction
of the individual sewage disposal system at the Stevenson
residence. The construction appeared to be in conformance with the
intent of the design.
If you have any questions or need additional information, please
give us a call.
Sincerely,
HIGH COUNTRY ENGINEERING, INC.
1�
Ti othy P. Beck, P.E.
Pr cipal Engineer
TPB.cso
cc: Sybrina Stevenson
923 Cooper Avenue • Glenwood Springs, CO 81601
Telephone:303-945-8676 • FAX:303-945-2555
Page 1 of 1
Lauren Brinker
From: Robert Layton [rglmd1@yahoo.com]
Sent: Monday, August 08, 2005 7:20 PM
To: Lauren Brinker
Subject: building permit--0160 Milburn Court
As per our conversation today, at present our home has three bedrooms, one of which is used as an
office. Our planned addition will increase the number of bedrooms to four, two of which will be used as
offices and two as bedrooms --a master bedroom and a guest bedroom.
Please contact me if there are any further questions.
Robert G. Layton
970-704-0155
8/9/2005
JOB NAME
JOB NO.
JOB LOCATION
s- C � L M dh�L
V -/ Z:Z,'2
D*I., TO
` n
0
q 9A q K-4
7
DATE STARTED
DATE COMPLETED
DATE BILLED
0 W/ y
?OA t77 J T
�O/9.Z
Zssv�
ad LSSL_12�"
7�-
$CbebP- I (0967
1=P-AMt�' ADD O/V. ADD!/V6 1 fbl2M
TOTS L= q 5PAM,3 AFTTk ieUM6DEL)
SENDING LM1L c�►�����-r�l�S
JOB COST SUMMARY
TOTAL SELLING PRICE
TOTAL MATERIAL
TOTAL LABOR
INSURANCE
SALES TAX
MISC. COSTS
TOTAL JOB COST
GROSS PROFIT
LESS OVERHEAD COSTS
% OF SELLING PRICE
NET PROFIT
JOB FOLDER Product 278 ®® NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MASS. 01471 JOB FOLDER Printed in U.S.A.
/ /---- - -- — LOT 25
HOus f
0
1250 GALLON 0
SEPTIC TANK `- N
_-_/-PRECAST CONCRETE NSTRIBUTION
BOX AND COVE AUTOMATIC SIPHON
co DOSING TANK
(SEE NOTE)
�. SEE DETAIL
LA
-4
(.4
c0
SCALE: 1" 30'
� 25' BUILDING SETBACK
/ LINE
(WELL CTON
- _ - ' 0 09- - ----
R = 132.87' ?'01'33„
T = 421.44' W /
L = 336.26' /
C8 = N 00r28'29" E rg0 9,5 y
C = 253.44'
SITE PLAN
INFILRATOR (TYP.>
INFILTRATOR UNIT
NATURAL GROUND
TRENCH CROSS -SEC T IQN (TYP.
N.T.S.
4" SOU
PVC PIF
11140
LOT 22
SOLID PVC
M DISTRIBUTION
(TYP.)
INFILTRATOR CONNECTION DETAIL
N TS
r.r.. VVABI.G CAr
CUT HOLE IN TOP OF INFILTRkTOR UNIT
FOR INSTALLATION OF INSPECTION WELL
PIPE
LING
RFORATED
NPE
INSPECTION WELL DETAIL
NTS
VICINITY MAP
SCALE: 1' - 2000'
NOTE:
TRENCHES SHALL FOLLOW CONTOURS
TRENCH PLAN
N.T.S.
I.S.D.S. DESIGN
4-BEDR013M HOME
USE 45 MIN/INCH PERC RATE. (SEE GENERAL NOTE NO. 8).
AVERAGE FLOWi 4-BR ■ 2 PERS/BR a 75 GAL/PERS PER DAY 600 GAL/DAY
DESIGN FLOW, 1.5 (AVE) = 900 GAL/DAY
SEPTIC TANK REQUIRED IS 1250 GAL.
TYPICAL ABSORPTION BEDS
AREA REQ' D . = 0/5 -Vt = 1125/5 -V45
= 1210 SQ.FT OF TRENCH BOTTOM
1210 X 0.6 = 724 SQ.FT. (REDUCTION FOR USING INFILTRATOR
UNITS)
RECOMMEND 240 LINEAL FEET OF TRENCH WITH INFILTRATOR UNITS.
SEE DRAWING FOR TYPICAL PLAN, SECTION, AND LOT LAYOUT.
GENERAL BED CROSS SECTION NOTES
I°
1. TRENCH LENGTH SHALL NOT EXCEED 100 FEET.
2. THE BOTTOM OF EACH TRENCH SHALL BE LEVEL.
3. DRAINAGE DITCHES ARE TO BE PROVIDED ABOVE TRENCHES, AS
NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION
AREA.
GENERAL NOTES
1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE EAGLE COUNTY
REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH
ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY NOTED ON THE
DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH
SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE -MENTIONED
REGULATIONS.
2. SEE ACCOMPANYING CALCULATIONS FOR FIELD SIZING.
3. CLEANOUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100
FEET ALONG THE HOUSE SEVER. MINIMUM SLOPE IS 1/4' PER FOOT.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL
COMPONENTS OF THIS SYSTEM WATER TIGHT (UP TO THE FIELD) TO
PREVENT INFILTRATION.
5. TOPSOIL COVER MAY BE VARIED (WITH 1-FOOT MINIMUM) TO ALLOW
LANDSCAPING.
6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO
WITHIN 1/2-FOOT OF FINAL GRADE.
7. LOCATIONS OF ALL COMPONENTS MAY BE VAR:ED AS NECESSARY AS LONG
AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED.
8. THIS DESIGN IS BASED UPON A PERCOLATION RATE OF 45 MINUTES
PER INCH PER AN ON -SITE PERCOLATION TEST PERFORMED BY HIGH
COUNTRY ENINGEERING, INC. ON MARCH 20, 1992.
9. TOPOGRAPHY SHOWN HAS BEEN DIGITIZED FROM A SALES MAP.
10. AUTOMATIC SIPHON FOR DOSING SHALL BE FLUID DYNAMICS MODEL
NO. 423, INSTALLED ON CONCRETE PEDESTAL INSIDE 1000 GALLON
PRECAST CONCRETE CISTERN.
RECEIVED
APR 2 0 IJ.,2
1
EAGLE COUNTY
COMMUNITY DEVELOPMENT
' -
1
- -
ii
1 4/9/92
FINAL DESIGN CONFIGURATION TP8
\01
NO. DATE
REVISION BY
_
STEVENSON RESIDENCE
I
I
75" 36'
EL JEBEL, COLORADO
i
_
FJDMMAL
WWAW D6008AL SYSTBA
NOTE: THIS DRAWING REPRODUCED FROM PRODUCT
LITERATURE PROVIDED 8Y INFILTRATOR SYSTEMS, INC..
-
-
LOT 26, OAK RIDGE III
TYPICAL INFILTRATOR UNIT
ASPEN
MOUNTAIN- VIEW FILING NO. 3
HwcoLtm 1134CRABIBIRMINC.
_
CC LI NWOOO SpFgM Co SW
DES. TPB
CK, FILE NO. SHEET 1
!
'_i
(300) 943- 6
DR. HMS
DATE 1/28/92 92004.01 . OF t