Loading...
HomeMy WebLinkAbout318 Eagle St - 211106111001INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH PPm� P.O. Box 179 - 550 Broadway • Eagle, Colorado 81631 e'pav f' Telephone: 328-7311 or 949-5257 or 927-3823 YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 91 39 -92 Please call for final inspection before covering any portion of installed system. OWNER: Roger Friesen PHONE: 524-7254 MAILING ADDRESS: P.O. Box 260 Gypsum, CO 81637 AGENT: PHONE: SYSTEM LOCATION: 318 Eagle Street Gypsum, CO 81637 LICENSED INSTALLER: Scott Green, B & B Excavating LICENSE NO. 13-92 DESIGN ENGINEER OF SYSTEM: INSTALLATION IS HEREBY GRANTED FOR THE FOLLOWING: Exlstlnf7 GALLON SEPTIC TANK OR GALLON AERATED TREATMENT UNIT. DISPERSAL AREA REQUIREMENTS: SQUARE FEET OF SEEPAGE BED 357 SQUARE FEET OF TRENCH BOTTOM. SPECIAL REQUIREMENTS: Or: 10 Infiltrators in trenches OR: 120' of 10" SB2 in Trenches Place inspection portals in each trench. <k _' Iao ENVIRONMENTAL HEALTH OFFICER: ` DATE: �� 1-9 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, C.R.S. 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. SECTION Ill, 3.21 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED ACCORDING TO THE REGULATIONS. FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM /S APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. � 7 INSTALLED ABSORPTION OR DISPERSAL AREA:! SQUARE FEET. INSTALLED SEPTIC TANK ) S4 I nG�LLONS DEGREES FEET SEPTIC TANK CLEANOUT TO WITHIN 8" OF FINAL GRADE, OR: PROPER MATERIALS ANDASSEMBLY YES NO COMPLIANCE WITH COUNTY/STATE REGULATION REQUIREMENTS: YES NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. COMMENTS: �F� 'i�'E .V�j Ci LA':A- \1 Y-N � l IP . ENVIRONMENTAL HEALTH OFFICER: CUV_ i Li /J/t DATE: 1 ` ENVIRONMENTAL HEALTH OFFICER: DATE: (RE -INSPECTION IF NECESSARY) RETAIN WITH RECEIPT RECORDS PERMIT APPLICANT/AGENT: OWNER: AMOUNT PAID: RECEIPT M: CHECK N: CASHIER: Incomplete Applications Will NOT Be Accepted (.Site•Plan MUST be attached) ISDS Permit ## Building Permit /i.37 APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT i ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. 0. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (Basalt) PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE 1125.00 MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" Yc�kyc�YC�Yc�c��k*���kytk�1C���c�YCYr���*�*Y[:1cYc�YtYt���*��YC:�yC��W�YCyc��rYcYrYc��Y�Y[y[�yc������c�Yck l r PROPERTY OWNER: / j c? j,,- ; -c i C P( MAILING ADDRESS: A0 D 40 PHONE : APPLICANT/CONTACT PERSON: 1f'1a,-PHONE: 3311 LICENSED SYSTEMS CONTRACTOR: /�77 �X�c �t/xaa PHONE: COMPANY/DBA: ADDRESS: PERMIT APPLICATION IS FOR: ( ) NEW INSTALLATION ( ) ALTERATION (;,,,,REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description: Tax Parcel Number: Lot Size: Phvsical Address: ��� z��i L r:. BUILDING TYPE: (Check applicable category) ( ) Residential/Single Family Numbe-.of Bedrooms ( ) Residential/Multi-Family* Number of Bedrooms ( ) Commercial/Industrial* Type TYPE OF WATER SUPPLY: (Check applicable category) ( ) Well ( ) Spring ( ) surface Public Name of Supplier: *These systems require design by a Registered Professional Engineer SIGNATURE: Date: ksc ycYcXYc**k YCYe*YcYrycycrrYCYryr*YtYCYcYr�cYcvr:cYc*}cYc9ck*YCYr}tYcycYcvrYcY:YcvcYrvcYcycvr�Yc�rY�kYc u AMOUNT PAID: RECEIPT #: DATE: CHECK #: CASHIER: TIME LOG: TRAVEL: PERC: FINAL: FL,,, m 6a "K) Memorandum TO: ISDS File #1139-92 FROM: Tania M. Busch'��`7 DATE: November 24, 1992 RE: Pending septic permit ***************************************************************** On 11/24/92, Roger Friesen and Scott Green were contacted as to the current status of the ISDS #1139. Both consented that the following situation occurred: The failing system was permitted on 4/17/92 and was installed that weekend. Due to the fact that it was a weekend, Roger Boyd (acting Assistant Environmental Health Officer) allowed them to cover up the system with out his final inspection. However, photos, as -built drawings, and receipts were to be sent to our office. According to Scott Green, he submitted the required documentation. However, this documentation has been misplaced. There is no reason to believe that the repair to the system was not made, considering that it was the property owner himself that alerted the county about his failing system. Therefore this system will be finaled as a repair. It will be assumed that an additional 120 feet of SB2 was installed to the existing system, along with a diversion box between the two fields allowing alternation between the fields in the future. See site plan in file to determine location of this addition. COMMUNITY DE%ELOPMENT DEPARTMENT (303) 32S S730 EAGLE COUNTY, COLORADO December 10, 1992 Roger Friesen P.O. Box 260 Gypsum, CO 81637 500 BROADWAY P.O. BOX 179 EAGLE, COLORADO 81631 FAX (303) 328-7207 RE: Final of ISDS Permit No. 1139-92, 318 Eagle Street, Gypsum This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your dwelling may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at 328-8755. Sincerely, Brenda Henderson Office Assistant Environmental Health /bh ENCL: Information Brochure Final ISDS Permit cc: Files COMMUNITY DEVELOPMENT DEPARTMENT (303) 328.8730 EAGLE COUNTY, COLORADO May 11, 1992 B & B Excavating, Inc. Attn: Scott Green Drawer 249 Vail, CO 81658 RE: Issuance of Individual Sewage Disposal System Permit No.: 1139-92 Dear Applicant: 500 BROADWAY P.O. [SOX 179 EAGLE, COLORADO S 1 b3 1 FAX (303) 328-7207 Enclosed is your ISDS Permit No. 1139-92 valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates tihe permit unless otherwise approved. Please call our office well in advance for the final inspection. The final inspection is to be done before any portion of the installed system is covered. The deadline for final inspections done by Eagle County Environmental Health is December 1. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County does not perform final inspections on engineer designed systems. Be aware that the specifications on the permit are minimum requirements only. Installers sihould bring this to the attention of the property owner. This permit does not indicate conformance with other Eagle county requirements. If you have any questions, please feel free to contact us at 328-8755. Sincerely, Brenda Henderson Environmental Health Administrative Assistant Enclosure cc: ISDS File ISDS PERMIT 1/3'7 PERCOLATION TEST Refz 0 %�r�w �l EAGLE COUNTY ENVIRONMENTAL HEALTH DEPT . �� _ i OWNER: LEGAL DESCRIPTION: MAILING ADDRESS: TYPE OF DWELLING: NUMBER OF BEDROOMS �����*•��c�r���r�r�r��r�r r��F' �r�c��r�r�r��r�r�r�r�r�r�r�r���r�r�r�r�rl 6e�aYc �r���ss cis«tor ��' 1 TEST HOLES PRE-SOAK D• YES NO rt{ �€ TTMF Armin nonmri 1 2 3 1 --- --- 2 3 ••...L. 1 �. 2 il1LL 3 KH'1'r, 1 2 bUlL FROFIL 0' i 11,5 8 1 2 15.0 i2 � - 3' 25 i9.o I�.75 17.5 /,37 c — 2 4 1q5 5 6 11 21.5 �3,5 2 Z,b 8 ,0 12, / 5 7S !� J Time to drop last inch 6,i0 5 5 PERC RATE: MINIMUM SEPTIC TANK SIZE: eKjvv, MINIMUM LEACH FIELD SIZE: 357m �- L rn�c iP or /p �n�l�Tr,«�as m TRENCHGS or /a0 COMMENTS: PERC TEST,,aPNE B S DATE: EnvironIgo al Heaj: h Officer rev. 6/90ks 07 /U 5,5 2- 'It im 9w 1139 - 318 Eagle Street, Gypsum, CO ... -ter Friesen JOB NO. doo IAQ I !l ATInKj A �t h - ok Ll - 2 BI TO W vvv��j� DATE RTED DATE COMPLETED DATE BILLED LL- o4 &/11-- s s ��s� /n �- �- '�?/// v/ ""Aversll'l" ia/e JOB COST SUMMARY TOTAL SELLING PRICE TOTAL MATERIAL TOTAL LABOR INSURANCE SALES TAX MISC. COSTS TOTAL JOB COST GROSS PROFIT LESS OVERHEAD COSTS % OF SELLING PRICE NET PROFIT JOB FOLDER Product 278 ®® NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MASS. 01471 JOB FOLDER Printed in U.S.A. INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1735-97 BP NO. TOG OWNER: NANCY FRIESEN PHONE: 970-524-7254 MAILING ADDRESS: P.O. BOX 260 GYPSUM CO 81637 APPLICANT: SAME PHONE: SYSTEM LOCATION: 318 EAGLE ST. "C" GYPSUM CO TAX PARCEL NO. 2111-061-00-003 LICENSED INSTALLERYACHECO CONSTRUCTION HERBERT PACHECO LICENSE NO. 16-97 PHONE: 970-524-7288 DESIGN ENGINEER: PHONE NO. INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: 1500 GALLON SEPTIC TANK 1125 SQUARE FEET OF TRENCH ABSORPTION AREA VIA 37 INFILTRATOR UNITS AS REQUESTED BY INSTALLER SPECIAL REQUIREMENTS: INSTALL IN SERIAL DISTRIBUTION IN TRENCHES. WITH A CLEANOUT BETWEEN THE TANK AND THE HOUSE AND INSPECTION PORTS IN EACH TRENCH. RAKE TRENCH SURFACES TO PREVENT SMEARING OF SOILS. FENCE OFF LEACH FIELD TO PREVENT ANIMALS FROM GRAZING IN THE AREA AND MAINTAIN ALL SETBACKS. CALL THE COUNTY FOR FINAL INSPECTION PRIORTO BACK FILLING ANY PART OF THE INSTALLA�TIION, OR WITH ANY QUESTION REGARDING INSTALLATION. ENVIRONMENTAL HEALTH APPROVAL: DATE: OCTOBER 20 1997 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS, CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 1147 SQUAREFEET(VIA 37 infiltrator units ) INSTALLED concrete TANK: 1500 GALLONS IS LOCATED 0 DEGREES AND 30' FEET FROM the cleanout, COMMENTS: Still nPacl nicturat of the rnnnPntinn to the hrniaa ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. ENVIRONMENTAL HEALTH APPROVAL - �� DATE: I ZI 12A- 7 (Site Plan MUST be attached) ISDS Permit # APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. O. BOX 179, EAGLE, CO 81631 328-8755/927-3823 (El Jebel) ************************************************************************** * PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 * * * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" PROPERTY OWNER: � � tC� i ewe PHONE: MAILING Al APPLICANT/CONTACT PERSON: /U04_VV �� t+ ip- ' 11 PHONE: ( c r MAILING ADDRESS: 5CCYA LICENSED ISDS CONTRACTOR: C 0_1�7 i PHONE: COMPANY/DBA: ADDRESS: *************************************************************************** PERMIT APPLICATION IS FOR: ( ) New Installation ( ) Alteration ( ) Repair *************************************************************************** LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Building Permit # (if known) Legal Description: Subdivision:, Et(ebs ;�-Tiling:_Block: Lot No. Tax Parcel Number: L- ( L- -� Lot Size: C . t! / K / Street Address: W *************************************************************************** BUILDING TYPE: (Check applicable category) () Residential/Single Family ( ) Residential/Multi-Family* ( ) Commercial/Industrial* TYPE OF WATER SUPPLY: (Check applicable ( ) Well ( ) Spring ( ) Su (} Public Name of Supplier: category) face Number of Number,of Type. Bedrooms Bedrooms *These systems require design by a Registered Professional Engineer SIGNATURE: J5 ��c_ Date: 1,6 b % TO BE COMPLETED BY THE,_COUNTY AMOUNT PAID: 6 g RECEIPT #: ' DATE: CHECK #: ��1� CASHIER:} Community Development Department (970) 328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 DATE: October 20, 1997 TO: Pacheco Construction FROM: Environmental Health Division Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 RE: Issuance of Individual Sewage Disposal System Permit No. 1735-97, Tax Parcel #2111-061-00-003. Property Location: 318 Eagle St. "C", Gypsum, CO., Friesen residence. Enclosed is your ISDS Permit No. 1735-97. It is valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Also enclosed is the ISDS Final Inspection Completeness Form. The items on this form need to be completed before you call for your final inspection. Also, please note any special conditions which may have been placed on the permit. If all items are not completed, a reinspection fee of $42.50 must be paid before a reinspection is made. Due to weather constraints, all permits issued before November 14, 1997 must be completed by, December 1, 1997 for final inspection. Please call our office well in advance to allow for scheduling of final inspection. Your building permit CO will not be issued until final approval has been given for the ISDS Permit. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files Enclosure: ISDS Final Inspection Completeness Form Community Development Department (970) 328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 EAGLE COUNTY, COLORADO December 15, 1997 Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 Nancy Friesen P.O. Box 260 Gypsum, CO 81637 RE: Final of ISDS Permit No. #1735-97, Tax Parcel #2111-061-00-003. Property location: 318 C Eagle St., Gypsum, CO. Dear Mrs. Friesen: This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, t Janet Kohl Environmental Health Department Eagle County Community Development ENCL:Informational Brochure Final ISDS Permit cc: files W~%a rg;.Ivltk -IF-LLJ,3.� PERCOLATION TEST EAGLE COUNTY ENVIRONMENTAL HEALTH DEPT. OWNER: La - Lod LEGAL DESCRIPTION: ZI I/ MAILING ADDRESS: 7 TYPE OF DWELLING - NUMBER OF BEDROOMS 47 TEST HOLES PRE-SOAKED: YESI _ NO TIME wamrD nrvrrw ­ I z SOIL FROI 1 2 3 1 2 1 I 2 3 1 2 3 F E3 [ 4*7,57 (ie­q) 28V 00 61 0 7 LI 3 s a(l` 6,2 q. 'a 4 r62 0 0, a, 2r 51 7 z fo 2 92 47t4 14 y. q j Time to drop last inch < PERC RATE: =-j am: MINIMUM SEPTIC TANK SIZE: I - 1�1-­ 1/1,-, - MINIMUM LEACH FIELD SIZE: A . i COMMENTS 4P J ff e, PERC TEST DONE BY: 7 V, /­ I -) ( -tV'6X T, L, - ' DATE: - _ Environmental Health Officer rev. 6/90ks 0 0 fz t-tit. y ISDS Permit # 1� Date ISDS Final Inspection Co=-leteness Fo Tank is gal. Tank Material -q— Tank is located -6 ft. and P"__—degrees from Jlv (permanent landmark) Tank is located _ft. and degrees from (permanent landmark) Tank set level. ---L--Tank lids within 81, of finished -grade. Size of field �._f t 2 3LT units lineal ft. Technology Lch Y./Li �2 fZr Cleanout is installed in between tank and house(+ 1/100ft). There is a -'IT" that goes down 14 inches in the inlet and outlet of the tank. Inlet and outlet is sealed with tar tape, rubber gasket etc. Tank has two compartments with the larger compartment closest to the house. Measure distance and relative direction to field. Depth of field ft. ,,Soil interface raked. __-L,�]�nspection portals at the end of each trench. Proper distance to setbacks. L---- Chambers properly installed as per manufacturers specifications. (Chambers latched, end plates properly installed, rocks removed from trenches, etc.) Other JV Ispection meets requirements. Copy form to installer's file if recommendations for improvement were suggested. ACTION TAKEN: Setbacks Well Potable House Property Lake Dry Tank Drain Water Lines line Stream- Gulch Field loo 25 20 10 50 25 10 10 Tank 50 10 5 10 50 10 10 SHEET NO. OF_ CALCULATEDBY DATE CHECKED BY DATE 2-5.1 —ac3!o- n: Groton Mas 0'471 7^ C:c!, PHME, TOU FFEE I-SX-224-5: -o�/75547 ale //Ap/� --7 Ile 1735-97 Tax# 2111-061-00-003 JOB NAME Lot #2, Keller Sub. FRIESEN 318 Eagle St. "C" r'.,., - (In JOB NO. JOB LOCATION BILL TO DATE STARTED /l V DATE COMPLETED DATE BILLED JOB COST SUMMARY TOTAL SELLING PRICE TOTAL MATERIAL TOTAL LABOR INSURANCE SALES TAX MISC. COSTS TOTAL JOB COST GROSS PROFIT LESS OVERHEAD COSTS % OF SELLING PRICE NET PROFIT JOB FOLDER Product 277 ®p NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MA 01471 JOB FOLDER Printed In U.S.A. N1 O O CV c0 LIJ O C-) O PRA BARN to remain GRAPHIC SCALE 20 0 10 20 40 ( IN FEET ) 1 inch = 20 ft. (E) FENCE to remoir F so LOT 2 (E) PASTURE 6455 Brushcreek Road 9.74 ACRES = 424,274.4 SF BLDG ENVELOPE J Z' W NOTE.• THE TRENCHES W M INFILTRATORS MUST BE (E) PASTURE CONSTRUCTED PARALLEL WITH THE CONTOURS. CLEANOUT 4—INCH DIAMETER, SDR35, BUILDING S WER LINE 1500—GALLON, TWO —COMPARTMENTS, PRECAST, CONCRETE TANK 4—INCH DIAMETER, SDR 5, EFFLUENT LINE Fr 56.25' I ,- �/ \ O LOC PT 10' 45' (10' MIN REQUIRED) (E) CCNC SLAB iHEDi PROPOSED NEW HOME \ 59' (20' MINIMUM REQUIRED)— (N EL J N) 1—CAR ( / V � \ � SERIAL DISTRIBUTION-1 LGARAGE SEE DETAIL A —A 6' MIN \ / STANDARD iNFIL TRA TOR I (E) 2—CAR GARAGE /---� — INSPECTION PORT SEE DETAIL x x x x ON —'— NEW gravel rive kPccll"111111 1oR iiiiiiiiiiiiiiiiio�►T 2—STORY;;;;; —FRAME HOMES (E)grovel rNe-ay 'iiiiiii_ i87E,26,SF DiiiJ (E) SEPTIC SYS / (E) SEPTICbe abandoned (VERIFY) - iiiiiiiii/ \ (E) PASTURE ,�O � 3 ElkJ .W` G /c <v E RE ti Q (E) gravel driveway <J — (E) FENCE. to remadr x x (E FENCE to remote x . ./� (E) grovel driveway / (E) grovel dri—y x % • (£J FENCE to remrnin � (Ef FENCE to remah N 00°00'00" E 690.00' rnrrL rnn vn Vr rnIIILJLI\ DETAIL A - A N. T. S. NOTE: SiTE PLAN BY CIRCLE WEST ARCHITECTURE, ROB KRUMHOLZ AIA 39, PMRA 77ON TEST R & TS Perc No. 1 Perc No. 2 F_erc No. 3 13.3 minutes per inch 13.3 minutes per inch 4 minutes per inch Average percolation rate recommended for design T = 10 minutes per inch. The Profile Hole and the Percolation test were done by Victor Crocco, Eagle County Environmental Health Department, on April 13,. 2004 SOIL PROFILE PROFILE HOLE 0 to 2 feet Topscul/Dark brown, silty clay 2 to 8 feet Light brown, sandy silt. No ground water encountered DESIGN CALCULATIONS Design percolation rate T = 10 minutes per inch Number of bedrooms = 5 Maximum daily Flow = Omox Qmax = 5 bdrms x 2 persons/bdrm x• 75 gallons/person/day x 15OX Qmax = 1125 gpd SEPTIC. TANK V = Qmax/24hrs x 30 hrs V = 1406 gallons Use 1500 gallon, two compartment precast concrete tank by Copland Concrete or equivalent ABSORPTION AREA A = Cm ax/5 x VT A = 112515xV10= 712s.f. Based on Applicotio Rate: A = 1125gp d/0.8 gpd/s, f. A = 1406 s. f. Standard Infiltrator Chamber System in a t-ench configuration with an allowed 50 percent reduction in the absorption area is recommended. Acorrected = 703 s. f. Surface area of one Infiltrator Chamber = 15.5 s. f. Use 45 Infiltrator Chambers in trenches, a: shown on the plan. NOTES: 1. Bends in the building sewer shall be lirnited to 45 degrees. 2. The septic tank shall be installed level, The tank shall have removable covers or manholes to within 8 inches of the finished grade, for inspection and cleaning. J. Excavate three (3) feet wide trenches. The horizontal distance from sidewall to sidewall between the trenches shall be a minimum of six (6) feet. 4. The bottom and the sidewalls of the trenches shall be raked to eliminate smearing. 5. Assemble and install the Infiltrator Chambers in the trenches according to the manufacturers recommendations. 6. Backfill the sidewall area with native on -site soil for proper support. 7. Backfill the trenches with a minimum ,�f 12 inches of tamped soil cover. 8. Avoid vehicle traffic over the system. 9. All installations shall meet the rules and regulations of the Eagle County Environmental Health Division, Chapter 4, Individual Sewage Disposal Systems. 10. The Septic System Installation shall be inspected by the Eagle County Environmental Health Department and by the Design Engineer prior to backfilling. 1500 GALLON "WO COMPARTMENT CONCRETE SEPTIC TANK 4'- N. T.S. BY COPLAND CONCRETE OR EQUIVALENT 1" 8" PLAN VIEW SIDE VIEW 11 0 e N (� cD cfl 00 N On 01-1 zM -0 ••� v o X v o w 00 00 a Q) 00 °' N U XN • M n a DRAWN BY.• L.P. CHECKED BY.• L. P. PROJECT NO.: 03155 DA TE:• MA Y 7, 2004 DRA wrNG No.: 03155SD. D WG SHEET 1- OF 1 INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, Colorado 81631 Telephone: 328-8755 YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1578 Please call for final inspection before covering any portion of installed system. OWNER: Nancy & Roger Friesen PHONE: (970) 521E-7254 MAILING ADDRESS: P.0. BOX 260. City: pgutq State: C9 ZIP: 81637 APPLICANT: Herbert Pacheco PHONE: 524-7288 SYSTEMLOCATION: 318 Eagle st.B, Gypsum, CO TAX PARCEL NUMBER: 9111-061*00-004 LICENSED INSTALLER: Pacheco C:OnS rrtctinm, Hprh PgCh2Cn LICENSENO: 31-96 DESIGN ENGINEER OF SYSTEM: INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: 1000 GALLON SEPTIC TANK ABSORPTION AREA REQUIREMENTS: SQUARE FEET OF SEEPAGE BED 570 SQUARE FEET OF TRENCH BOTTOM. via 19 infiltrators as requested by owner SPECIAL REQUIREMENTS: Install in -.-serial distribution with inspection portals in each trench, and a cleanout between the tank and the building- Rakp trench Gidecall Do not al1nw hnrsp nn the leach field- Call ENVIRONMENTAL HEALTH APPROVAL: DATE: CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25- 10- 104. 1973. AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 570 SQUARE FEET. INSTALLED SEPTIC TANK: 1000 GALLON 110 DEGREES 6 t 5 tt FEET FROM the cleano t SEPTIC TANK ACCESS TO WITHIN 8" OF FINAL GRADE AND PROPER MATERIAL AND ASSEMBLY X YES NO COMPLIANCE WITH COUNTY / STATE REQUIREMENTS: X YES —NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS CORRECTED. COMMENTS: ENVIRONMENTAL HEALTH APPROVAL: DATE: V ENVIRONMENTAL HEALTH APPROVAL: DATE: (RE -INSPECTION IF NECESSARY) RETAIN WITH RECEIPT RECORDS APPLICANT / AGENT: OWNER: PERMIT FEE PERCOLATION TEST FEE RECEIPT # CHECK # � r Y APR 2 6 1996 ISDS Permit # Building Permit #. APPLICATIO.NfitjPQ, 4--,fj, lgT-VV��UKUi SWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE- EAGLE COUNTY P.O. BOX 179 EAGLE, CO 81631 328-8755/927-3823(Basalt) PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 ************************************************************************** PROPERTY OWNER: l U 'kya O F\, e,SL?y, MAILING ADDRESS: P•o •�o� ��jQ �y pSyyU �. 81b3 ? PHONE • APPLICANT/CONTACT PERSON: Wer4tL� 1"ct( eC.a PHONE: /%'S %2�� LICENSED SYSTEMS CONTRACTOR: JRG&CO (&--?5, ADDRESS: tp,Di !Ja k /l { Cv - 71631 PHONE • 0 ?D -52-y-7,7_8 ' PERMIT APPLICATION IS FOR: (X) NEW INSTALLATION ( ) ALTERATION ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description: 019 Enle S' B ��Ipsurn � �a• S �� Parcel Number: PQ _Lot size: 1•27y /�crzS Physical Address: � U U o�q l e �J � jJ!GU-yo.- BUILDING TYPE: (Check &,jv f{� (�() Residential / Residential / Commercial / TYPEL-/ WATER SUPPLY: applicable category) Single Family Number Multi -Family* Number Industrial* Type_ of Bedrooms 3 of Bedrooms Well( ) Spring ( ) Surface ( ) Public ()() Name of Supplier: `t ®rq, *These systems require design by a Registered Professional Engineer NOTE: SITE PLAN MUST BE ATTACHED TO APPLICATION MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" SIGNATURE • 3h2-® � DATE • AMOUNT PAID: y RECEIPT# I O 2— DATE: \� CHECK # CASHI Community Development Department (970)328-8730 Fax: (970) 328-7185 TDD: (970) 328-8797 EAGLE COUNTY, COLORADO May 20, 1996 Nancy and Roger Friesen P.o. Box 260 Gypsum, CO 81637 RE: Final of ISDS Permit No. 11578-96 Parcel #2111-061-00-004. Property location: 318 Eagle St., Gypsum, CO. Dear Mr. & Mrs. Friesen, Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631 -0179 This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at 328-8755. Sincerely, Janet Kohl Environmental Health Department Eagle County Community Development ENCL:Information Brochure Final ISDS Permit cc: files DATE: May 6, 1996 TO: Pacheco Construction FROM: Environmental Health Division RE: Issuance of Individual Sewage Disposal System Permit No. 1578-96 Tax Parcel #2111-061-00-004. Property Location: 318 Eagle St., Gypsum, CO., Friesen residence. Enclosed is your ISDS Permit No. 1578-96. It is valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Please call our office well in advance for the final inspection. Also enclosed is the ISDS Final Inspection Completeness Form. The items on this form need to be completed before you call for your final inspection. Also, please note any special conditions which may have been placed on the permit. If all items are not completed, a reinspection fee of $45.00 must be paid before a reinspection is made. Your building permit CO will not be issued until final approval has been given for the ISDS Permit. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files LJUJ rGKI"Il.l= L mil\ =-�� PERCOLATION TEST EAGLE COUNTY ENVIRONMENTAL HEALTH DEPT. OWNER:�,e � LEGAL DESCRIPTION;_ MAILING ADDRESS.:_��1�, TYPE OF DWELLING: �' NUMBER OF BEDROOMS TEST HOLES PRE-SOAKED: YES NO TIME WATER DEPTH INCHES OF FALL RATE SOIL PROFI= 1 2 3 12 3 1 2 3 1 2 LV f2lk ILI 14 Ivy-) C f �� li a" 1 �����,2i�� 31 l� (?� n'�� r �/ D '/� �3 ► �v 4 / 658 jP ILL (14- c � j ' Vz_ 1 (!4 �U 8 ls',U� 171f f' 6G t Time to drop last inchj;r r'�cai`�cSciL PERC RATE: MINIMUM SEPTIC TANK SIZE: �, (x�� ��C f 0�,, MINIMUM LEACH FIELD SIZE:57 O l \ COMMENTS: la, ;�ik C11�Dvt� 615f',e-4) t1Y1 Ntan C)V* i AF,c./GC PERC TEST DONE BY: DATE: Environme a Health Officer rev. 6/90ks ISDS Final Inspection. Co pleteness Form Tank is I or0 gal. Tank Materials Tank is located CD �5 ft. and //06 degrees from Cb-&n (permanent landmark) Tank is located ft. and degrees from / (permanent landmark) r/ Tank set level. �ank lids within 8" of finished grade. Size of field ft2 G► units lineal ft. Technology 1 U , ��EL ✓ Cleanout is installed in between tank and house(+ 11 100ft). There is a "T".that goes down 14 inches in the inlet and outlet of the tank. -_Inlet and outlet is sealed with tar tape, rubber gasket / etc. y Tank has two compartments with the larger compartment closest to the house. /Measure distance and r-elati've direction to field. �f Depth of field 2 ft. Soil interface raked. inspection portals at the end of each trench. Proper distance to setbacks. Other Inspection meets requirements. Copy form to installer's file if recommendations for improvement were suggested. ACTION TAKEN: Setbacks Well Potable Field 100 25 Tank 50 10 House Property Lake Dry Tank Drain line Stream Gulch 20 10 50 25 10 10 5 10 50 10 * 10 0 EMERNE111111wis, ' MMONS SOMEONE P- mmilmn ' n sons ominamnammur■ ■mmtm small■ IRENE NONE ■MER ��'�!'�'�►/'W-U-f�__mom■ muninlm■mommmNONE Elinism ■■mmonsmEni IIIosimmomomms OMEN 1578-96 Tax#2111-061-00-004 JOB NAME 318 Eagle St. Lot 1 FRIESEN Gypsum JOB NO. 4? 0 JOB LOCATION BILL TO DATE STARTED DATE COMPLETED DATE BILLED t �.. ZL IF i� 3 1 JOB COST SUMMARY TOTAL SELLING PRICE TOTAL MATERIAL TOTAL LABOR INSURANCE SALES TAX MISC. COSTS TOTAL JOB COST GROSS PROFIT LESS OVERHEAD COSTS % OF SELLING PRICE NET PROFIT JOB FOLDER Product 278 ®0 NEW ENGLAND BUSINESS SERVICE, INC., GROTON. MA 01471 JOB FOLDER Printed in U.SA QZOOW00''. .� ITI O OD 0 A O. v v P 7t ,. fTl O: rn L n D6)0 D. ;N Z m n m(1)� D ��` w z 11 11 11 II Y 0 Hi ON , ou 5co M �' axe /• •/ /• � aC��`�� f.�`� O �'`� ' m r-;o y /•, /CoVA m S r*t.w m,M sz.0 �' 1 i l ,ZL'so� i T R A' C T �� \ ; Hlnas X -- X v O� O O O of � Y O m, i j OD o _ , I1� a1 0 ��