HomeMy WebLinkAbout220 Sam Grange Ct - 239122204004 - 1133-92ISINDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH P.O. Box 179 - 550 Broadway • Eagle, Colorado 81631 Telephone: 328-7311 or 949-5257 or 927-3823 YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE, PERMIT NO. 1133 Please call for final inspection before covering any portion of installed system. OWNER: Ken Braunschmidt PHONE: (916) 891-4966 MAILING ADDRESS: 2941 DgVt-on Pond, Chico, CA 95998 AGENT: PHONE: SYSTEMLOCATION: 220 Same Grange, Carbondale CO 81623 LICENSED INSTALLER: Zamora Excavating, Inc. Joe Zamora LICENSE NO. 07-92 P.O. Box 754, Carbondale, CO 81632 DESIGN ENGINEER OF SYSTEM: Peter Belau, Enartech, Inc. INSTALLATION IS HEREBY GRANTED FOR THE FOLLOWING: 1250 GALLON SEPTIC TANK OR GALLON AERATED TREATMENT UNIT. DISPERSAL AREA REQUIREMENTS: 1 1 38 SQUARE FEET OF SEEPAGE BED SQUARE FEET OF TRENCH BOTTOM. SPECIAL REQUIREMENTS: 32 Infiltrators in trenches; 380' of 10" SB2. Due to slow perc rate use trench system. Permit valid only upon engineer review and certification. See attachment for engineer review requirements. ENVIRONMENTAL HEALTH OFFICER: 6 ' DATE: CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, C.R.S. 1973, AS AMENDED, 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. SECTION Ill, 3.21 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED ACCORDING TO THE REGULATIONS, FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: SQUARE FEET. INSTALLED SEPTIC TANK: 1250 GALLONS DEGREES FEET SEPTIC TANK CLEANOUT TO WITHIN 8" OF FINAL GRADE, OR: PROPER MATERIALS ANDASSEMBLY YES NO COMPLIANCE WITH COUNTY/STATE REGULATION REQUIREMENTS: YES NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. COMMENTS: Installed per engineer design specifications - ENVIRONMENTAL HEALTH OFFICE - DATE: ENVIRONMENTAL HEALTH OFFICER: DATE: (RE-INSPrECTION IF NECESSARY) RETAIN WITH RECEIPT RECORDS PERMIT APPLICANT/AGENT: OWNER: AMOUNT PAID: RECEIPT #: CHECK #: CASHIER: Incomplete Applications Will NOT Be Accepted (site Plan MUST be attached) ISDS Permit # 771133 Building Permit # _a — APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. O. BOX 179 EAGLE, CO 81631 328-8755/927-3823 (Basalt) ��*Yl�k:k�:kyc*J[:c*:kHC*Yc:kkyt:k'9cYtYyl:k*•.rkk;kHt*:Y'k:k*k'�Cyc'k::Yl�c;k:Yyc:k4c:�:F:':kXx*':CYCycx'yC:FYc',k�c:��'c�kycXk:kYC*�l' PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE 8125.00 * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" :kYck:kYc*YcYc*:�Yc*Ycic:kk�rkYCYcYCYCYr�k�+r:kYrJck�c�kk:4ycYtW.k*�c�k;kYt:k�k�yckYc�Ycyc�*�c'�k;kYt�Yc:k:��•/G*Yt:kkk•k�c*'�t*:k PROPERTY OWNER: r-�-�I�'����a� iC�ni[ Cry. MAILING ADDRESS: 9VN Cz PHONE: `Ile_ APPLICANT/CONTACT PERSON: PHONE: LICENSED SYSTEMS CONTRACTOR: Toe Zar,-,a--a PHONE: COMPANY/DBA: ADDRESS: * * * k * * * * K: * * * * * * * * * * * * * * * * * * * * * * * * '* * * * * * * * * * * * * * * * * * * * * * r• * * * * * * * * * * * * * * * * * * PERMIT APPLICATION IS FOR: ) NEW INSTALLATION ( ) ALTERATIO14 ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description: Tax Parcel Number: ��� ) a�2_yy _60 -1 Lot Size: Physical Address: aw C A! ,Q BUILDING TYPE: (Check applicable category) (,s-Residential/Single Family Number of Bedrooms �) ( ) Residential/Multi-Family* Number of Bedrooms ( Commercial/Industrial* Type TYPE OF WATER SUPPLY: (Check applicable category) ( ) Well ( ) Spring ( ) Surface (� Public Name of Supplier: 74,51PC,.' Vic *These systems require design by a Registered Professional Engineer SIGNATURE: ? Date: AMOUNT PAID: 1��, ("�C7 RECEIPT 279y DATE: CHECK « : `S(j'7 CASHIER! TIME LOG: TRAVEL: ; 01 �s►2 j �,5 PERC: %6z,2 FINAL: COMMUNITY DEVELOPMENT DEPARTMENT (303) 328-S730 EAGLE COUNTY, COLORADO August 20, 1992 Ken Braunschmidt 2941 Dayton Road Chico, CA 95928 RE: Final of ISDS Permit No. 1133-92 :00 BROADWAY P.O. BOX 179 EAGLE. COLORADO 81631 FAX (303) 32S-7207 This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your dwelling may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at 328-8755. Sincerely, 2'- Brenda Henderson Office Assistant Environmental Health /bh ENCL: Information Brochure Final ISDS Permit cc: Files BP# 5226 COMMUNITY DEVELOPMENT DEPARTMENT (303) 328-8730 EAGLE COUNTY, COLORADO April 17, 1992 Enartech, Inc. Peter Belau 302 Eighth Street Suite 325 P.O. Drawer 325 Glenwood Springs, CO 81602 RE: Issuance of Individual Sewage Disposal System Permit No.: 1133 Dear Applicant: 500 BROADWAY P.O. BOX 179 EAGLE. COLORADO 3163 1 FAX (303) 328.7207 Enclosed is your ISDS Permit No. 1133 valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Please call our office well in advance for the final inspection. The final inspection is to be done before any portion of the installed system is covered. The deadline for final inspections done by Eagle County Environmental Health is December 1. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County does not perform final inspections on engineer designed systems. Be aware that the specifications on the permit are minimum requirements only. Installers should bring this to the attention of the property owner. This permit does not indicate conformance with other Eagle County requirements. If you have any questions, please feel free to contact us at 328-8755. Sincerely, Brenda Henderson Environmental Health Administrative Assistant En'losure cc: ISDS rile f'l\F( EAGLE COUNTY, COLORADO Dear I.S.D.S. Applicant: 500 RR '.f 'i..'• 1 1'0.R'\. Your application for an Individual Sewage Disposal System ( ISDS ) Permit for Ld 4 7A-- has been received. Issuance of your permit is on hold until the following materials or fee(s) are submitted. % — Payment of $150.00 Application Fee Payment of $125.00 Percolation Test Fee Site Plan Licensed System Contractor (:See attached list) y Engineer Design -Y Other: If you have any questions please call, 328-8755. When calling or submitting information please reference your ISDS application # //33 Please submit information to: Eagle County Environmental Health Division P.O. Box 179 500 Broadway Eagle, CO 81631 ISDSHOLD.LET ISDSDSK BH392 April 14, 1992 Permit - 1131 Lot 4, The Summit & Oak Ridge II, Filing 3 220 Sam Grange, Carbondale Parcel # 2391-222-04-004 Ken Braunschmidt Special Requirements; Due to slow perc rate use TRENCH system. Permit valid only upon engineer review and certification. 1. Registered Professional Engineer must conduct site evaluation. 2. Certification letter must accompany permit. 3. Registered Professional Engineer will be responsible for certifying that the system has been properly installed and providing final site plan to Eagle County. 4. Inspection portals must be installed in each trench. ISDS PERMIT 1133 PERCOLATION TEST EAGLE COUNTY ENVIRONMENTAL HEALTH DEPT. OWNER: 1�t LEGAL DESCRIPTION: Saw Grah,e, C. , MAILING ADDRESS: TYPE OF DWELLING: NUMBER OF BEDROOMS f TEST HOLES PRE-SOAKED: TTMR YES NO LiAMVn r%minmv OUIL VRuk,11 1 2 3 1 2 3 1 2 3 1 2 l°rq olr- loam Q 6 0 sayn 15 "30 1.75 1.5 ), 75 a5 )5 ­20 2.10 2 1,75 I2_5, 3� 40 I ZS L 1> 3. z5 >> iz 5 z 5 rI �D t i�� i►4s"I Ir. 1 4 4'5 Z$ 2,C7 z1! 5' z5 - 6 z1D o �•G� z. 3.7� Surprly%f'31 j 7eA o� 4P for C re,,ks �ow SrfeS �ur�� {7 2 75 ?, 6 rJ U, 0 F25 ? 5 1Z ; h ' �J ,/� t!l ,n �i !/U Z/D if� dMvn, Time to drop last inch PERC RATE: y5E /0 MINIMUM SEPTIC TANK SIZE: MINIMUM LEACH FIELD SIZE: //39 P' 3.2 COMMENTS: �roposel�aaZ }o V,11 a�mJle ,inp v - Due eh9fifePi�^ le///ecl cr� cPs fic� fiM cel- �w�nN /Hd�7 GCCorr�oaky v / PERC TEST DONE BY : /� �Ocrrr„ t 11) — Envirogmental T ealth O rev. 6/90ks �X9�=//3g�/Z 5 cer DATE: f115V 77 �6 x �106 5 le = 90dla�, s //3F T1z e�� e�me= /8 P/ z //3 F Ft z in' y 1139 J-/ 3 = 306 /-/ oI /0 518). C AF'R- 1 t -92 FR I '3 : 53 EHAFR'T"EC:H I NC ENARTECH Inc. Consulting Englnevs and Hydrologists ApR 1 `� FAX TRANSMISSION NOTE DATE: q " P % " 1 -.)-. NUMBER OF PAGES (INCLUDING THIS COVER SHEET) 7- PERSON CALLED: DATE: _ ,Yh 7 TIME: l! ' I ACTION: IN CASE OF A PROBLEM, CALL �>✓�3�t��. �� AT (303) 945.2236. -- -- I if checked, please call to confirm receipt of documents. Our FAX number is (303) 945.2977. Additional instructions,/comments; C 56_ � � Pf L- t 'ram --► F T T LA) I I� e7l-c . Pff4-m I T �'�� '3'° S 5 ?'.' ��,� ,��, Do 302 Eighth SVOW, Suite 325 P,O. DP8VV0r i80 01snWOOO Springs, Coioredo 81802 1303j 945.2236 1 r — 92 FR I 53 E"ARTECFA I FaC _ F� _ 02 April 17,1992 Mr. Robert H. Magel, Jr. 600 E. Hopkins, Suite 303 Aspen, CO 81611 RE: New residence, Sewage ]Disposal Dear Mr. Magel, This letter is to provide the design and design certification for the individual sewage disposal system for your proposed residence located on Lot 14 of Aspen Mountain View Subdivision in Eagle County. Please find enclosed the following information: • Site Plan of Lot 14 sho,%ring the location of your proposed residence and leachfield. • Field Percolation Test Results • Soil Absorption System Design Calculations Ile field percolation tests were performed by Roger Boyd, Eagle County Environmental Health Officer. I have reviewed these test results and have inspected the site, including subsurface soil conditions, and I accept these percolation test results for the design of your sewage disposal system. The recommended sewage dispose! system for your residence is a 1000-gallon septic tank (or larger) with a soil absorption system. Any of the following alternative soil absorption systems may be constructed. 1. A 675 square -foot standard leachfield. 2. A 6 foot wide by 113 foot long standard absorption trench. 3. 225 feet of 10-inch diameter AIDS "SB2" Gravelless Pipe. 4. 22 standard (12-inch) "Infiltrator" chambers in a seepage bed. 5. 18 "Infiltrator" chambers in a seepage trench. 6. 25 "Contactor" chambers in a seepage bed or trench. "r-M- f --y- 1- Pi 1 9 : 54 E=NARTE=NCH I " C 1} _ 0 3 Mr. Robert H. Magel, Jr. Page - 2 All of the above are minimum requirements; additional soil absorption may be installed at your option. The construction of the sewage disposal system shall be in accordance with the following conditions: 1. Construction shall conform to Eagle County Individual Sewage Disposal System Regulations. 2. Construction utilizing non-standard materials shall conform to the manufacturer's requirements. 3, The Design Engineer (me) or a qualified Professional Engineer shall inspect and approve the installation of the soil absorption system prior to backfiilling, 4. Da not install the soil absorption system in areas where bedrock is located within 4 feet of the bottom of the system. Please give me a call if you have any questions, and please make sure that the system installation contractor contacts me for an inspection prior to backfilling the system. Sincerely, XARTiCH, INC Peter Belau, P.E. Civil and Environmental Engineer PB/des Enclosures cc: Roger Boyd, Eagle County Pa x 734 OIA)92 •� .� i . — » r m X Z:- Z� t"YF-4R TEiCH I NL p _ 0 4 Q� = V in ,: ( s t, _ _ as c� Y, e v' •.r 1 �-a u.. eta ate' -ye . Legal Dasarxption: Lot 14, Aspen Mountain View, Second Filing, Eagle County► Co. •-, * rt - i - r r� 1 ti 1= r-4 f-i FZ T E C H S hi C _ F' _ 0 .5 SENT BY:EAGLE COUNTY 4-15-02 14.27 3033267207-» 3039452977;* 2/ 2 9SDS PERMIT # 01�)� PERCOLATION TENT EAOLE COUNTY ENVIRONMENTAL HEALTH DEFT. LEGAL DESCRXPTX0X: mw..L View 14 MAILINd ADDRESS: 'XPE OF DWELLING; NUMBER W+�w+k*wry or BEpROOMS � S w w �rwww�r wYr �r�rstw,t�r*w wtkw TEST HOLES PRE-SOAKED: YES NO TIME WAFER DEPTH ' XXCHE8 OF FALL RATE SOIL PRbF]CL x z 3 1 Z 3 y I 2, �1►c i', t a G 07 �,�« ' 40 al 1�0 31 41 ,247 a3..3 61 4e'p 1 .;50 51 .11 L 14 ? $ 2A 1 S 3i 443y. 4 - +2.0 za 2 ` i f � , �r zrI Time to drop last Inch Y FERC RATS « �, mp, MINIMUM SEPTIC TANK SIZE: le)ec9 MINIMU'M LEACH VILL3] SIZE: � ����� �re�r.�' �"rit r �`� ,,,�' %4�59� ► � L:.�.��, 'COMr'IE%tT S : �, PER,+C TEST DONE BY DATE:� /�' • �/ Environmen t Cffi,cer 4 t / rev. 6/50k it�� I 'L� FirK— 1 f—y2 FF;' I 3 r cG EM�4R_FE:C -i I H Cl r E 17A ENARTECH, INC. 302 Eighth Street, Suite 325 P.O. Drawer 160 GLENWO0D SPRINGS, CO 81602 (303) 945.2236 J � l �f A'6r'e L_ r 1 SHEET NO. I of ' r DAI,MLA EDBY_.,-. 2 'ice GATE_ C,HLCKED BY. DATE anal e rar K— 1 Y —92 EF2 I 54 _ 15 i EMC7F? TEC: H I F#C p p7 Joe ENARTECK INC. SHEET NO.. _ - 302 Eighth Street. Suits 325 or — PA A Drawer 160 CAOUL4"ED a DATE. GLENWOOD SPRINGS, CO 81602 (303) 943.2236 CHECKED BY—� DATE r I . ..... �' ......... �.._ ................ I ,, ,. , :,,,,..,,,,,.,,. 1 a ...... ...................... �................... f....... „�...,, . I I »�,,,,,.,..,,,, ,...... .... ,4. , ............. „.... ........... ........... .... ... ..... I I ,i........... . , _,.. ..... ... ... .. ....... ...3 .. ... .. ..... .. ..... ...` ............ ...f ...�..... �,�, ..�. ........ ..... .....,e..... ............ .. .._..... 3 .,,» ,. i ., .., .._............__ .......................... .... � ... ..... I ,.,,, t ,.., , ' . ' .,., .,. ................... „_................,,........,.t.,.....f, .........,,, ............. ,„...».,, ,,,,,,,,, , . ,,,,,,,, „ i,.,».............................., ..:. ..... ,,....... „..............»..»:, :,} ::........... .. ... i ,, : ......... , , , .,I,, ,r'„r , .....,...., ...... ,».. ,.„ ,„ ».. .... .... j.............I ... ....... .,• �,....... ............. ., , ., ,i ........... ......„.............. ,,, ,,.,,,,.,..'J. .„ ... ,:,, L,.......,..� L.... ..... .I ..........I ...1 ... L . .. ......... ........ , ,,, „ I I i... ,,,» ., . ..... .... I .....,i„„,»„,� » ........ ..... ....,.,,....... 1 „ ..., . I.. , , ,,. I,. ,, ,, ., I 1 I I �.... �...„n..... ........ + + ....... .. » „ ,,, ,,,,,,,_.......,,..�.,,, „„,r„ ,,, ].......... ......... .., ........... ... ! ....... 1,,, }.... ..f .,........ I ........................ .„I:...,....,....,,..,,.,.,.. ...... ........ + „r»...... ............ .... ... ,,, ,,,,,......, . .................... ; , .,................,, . ....... ..... f .......... „............ i »r,».......... ....... ..... ...... ....... ....., .,...,», ........ » »... ..........» ..., „ . ..�,., .,, ,.,,,,,,.ir......... .„. ................ I .,,, ,,,,,,,,,,,I...........,...... ,....,.,,., I , »» .„.......f........................ L....................�...,...._ ..........,,I„,,,,,,,,,,,,,,,,,,,,„4.,.,,,.».,..i.,,,,,,.:..,�.................... j f 4 , , I ENARTECH Inc. Consulting Engineers and Hydrologists April 22, 1992 Mr. Ken Braunschmidt 2941 Dayton Road Chico, CA 94928 RE: Eagle County Individual Sewage Disposal Permit No. 1133 Dear Mr. Braunschmidt: P. ECEIVEDE EAGLE COUNTY DEVELOPMENT . i1401r This letter is to provide the design review and certification for the individual sewage disposal system for your proposed residence located at 220 Sam Grange Court, which is Lot 4 of The Summit and Oak Ridge II Subdivision, Filing 3, in Eagle County. ISDS Permit No. 1133 issued by Eagle County for this project is enclosed, along with the Special Requirements, Field Percolation Test Results, Design Calculations and Site Plan associated with this permit. I have reviewed the enclosed information and have inspected the project site, and hereby accept the design of proposed system as described in ISDS Permit No. 1133. I am forwarding this Permit on to your system installation contractor so he may proceed with the installation. The system installation contractor must contact me for an inspection prior to backfilling the system, it would be best if he gives me as much prior notice as possible to avoid potential scheduling conflicts. If you have any questions, please give me a call. Sincerely, ENARTECH, INC. Peter Belau, P.E. PB/des Enclosures cc: Roger Boyd, Eagle County Joe Zamora, System Installer P343-01 (P343_01A)92 DESIGN CERTIFICATION HE y •00eos 302 Eighth Street, Suite 325 P.O. Drawer 160 Glenwood Springs, Colorado 81602 (303.) 945-2236 �:OMMLINITI DEVELOPMENT DEPARTMENT (303) 32S 8'30 EAGLE COUNTY, COLORADO April 17, 1992 Enartech. Inc. Peter Belau 302 eighth Street Suite 325 P.O. Drawer 325 Glenwood Springs, CO 81602 RE: Issuance of Individual Sewage Disposal System Permit No.: 1133 Dear Applicant: Soo RROAMVAY P.O. PDX 1 7g EAGLE. COLORADO S 163 1 FAX (303) 32g. 20, nr.(% APR201992 { Enclosed is your ISDS Permit No. 1133 valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Please call our office well in advance for the final inspection. The final inspection is to be done before any portion of the installed system is covered. The deadline for final inspections done by Eagle County Environmental Health is December i. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County does not perform final inspections on engineer designed systems. Be aware that the specifications on the permit are minimum requirements only. Installers should bring this to the attention of the property owner. This permit does not indicate conformance with other Eagle County requirements. If you have any questions, please feel free to contact us at 328-8755. Sincerely, Brenda Henderson Environmental Health Administrative Assistant Enc1osui:e C: i DU - - , i r INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH P.O. Box 179 - 550 Broadway • Eagle, Colorado 81631 Telephone: 328-7311 or 949-5257 or 927-3823 YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1133 Please call for final inspection before COVerinn inv nnrtinn of incfallorl c� +c OWNER: Ken Braunschmidt PHONE: (916) 891-4966 MAILING ADDRESS: AGENT: PHONE: SYSTEM LOCATION: 220 Samer n e Carbondale Co8162 LICENSED INSTALLER: Zamora Excavat; ng, Inc Joe Zamora LICENSE NO. 07-92 P.O. Box 754, Carbondale, CO 81632 DESIGN ENGINEER OF SYSTEM: Peter Belau, Enartech, Inc. INSTALLATION IS HEREBY GRANTED FOR THE FOLLOWING: 1250 GALLON SEPTIC TANK OR GALLON AERATED TREATMENT UNIT. DISPERSAL AREA REQUIREMENTS: 1 1 38 SQUARE FEET OF SEEPAGE BED SQUARE FEET OF TRENCH BOTTOM. SPECIAL REQUIREMENTS: 32 Infiltrators in trenches; 380' Of 10" SB2. Due to slow perc rate use trench system. Permit valid only upon engineer review and certification See attachmentfor engineer review requirements ENVIRONMENTAL HEALTH OFFICER: DATE: CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REOUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, C.R.S. 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. SECTION Ill, 3.21 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED ACCORDING TO THE REGULATIONS. FINAL APPROVAL OF SYSTEM: 0T0 BE COMPLETED BY INSPECTORr NO SYSTEM SHALL BE DEEMED TO BE IN COMLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: SQUARE FEET. INSTALLED SEPTIC TANK: GALLONS DEGREES FEET SEPTIC TANK CLEANOUT TO WITHIN 8" OF FINAL GRADE. OR: PROPER MATERIALS AND ASSEMBLY YES NO COMPLIANCE WITH COUNTY/STATE REGULATION REQUIREMENTS: YES NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. COMMENTS: ENVIRONMENTAL HEALTH OFFICER: DATE: ENVIRONMENTAL HEALTH OFFICER: DATE: (RE -INSPECTION IF NECESSARY) RETAIN WITH RECEIPT RECORDS PERMIT APPLICANT/AGENT: OWNER: AMOUNT PAID: RECEIPT N- CHECK M: CASHIER' April 14, 1992 Permit - 1131 Lot 4, The Summit U Oak Ridge II, Filing 3 220 Sam Grange, Carbondale Parcel V 2391-222-04-004 Ken Braunschmidt Special Requirements: Due tc slow perc rate use TRENCH system. Permit valid only upon engineer review and certification. 1. Registered Professional Engineer must conduct site evaluation. 2. Cer7ification letter must accompany permit. 3. Registered Professional Engineer will be responsible for certifying that the system has been properly installed and providing final site plan to Eagle County. 4. Inspection portals must be installed in each trench. ISDS PERMIT PERCOLATION TEST EAGLE COUNTY ENVIRONMENTAL HEALTH DEPT. OWNER: I(C4 LEGAL DESCRIPTION: SG, bra"KB Cf_ Lof 4� - — ; MAILING ADDRESS: TYPE OF DWELLING: NUMBER OF BEDROOMS TEST HOLES PRE—SOAKED: YES_ NO _ TIME wnmvn 1 2 3 L7 ] 2 3 1 2 3 1 2 SOIL PRO: or Vic- Ic 0' 5114k } S. )'30 3/ 3Z 1.75 1.5 VS �S a 5 a ED 20 a20 20 11 2' �I 35 36 3-7 I.S75 1.75 3.0 .125 .15 �.� -fd zo �Lp 3, 40 :+� 141� az y7 s I.h75 2.0 3.;5 3.3-75 .ems 1z5 ./zs /2-5 .12S �,+ypi<�.1 ro,. 4 a + ev- 5 � �o s) s2 z.z5 .2.25 3.5 — z� /2 5 \ �Q M�YI ` �O 1//t / 6 �� 56 5-7 2.5 a.a5 3. �z5 zs — - 00 F. 13 3.75 .12-5 — iz5 Ild / � min ._G J ^ 1 05 2• 6;5 1.5 3.g75 6� �, o iz5 /z 5 17- Time to drop last inch 44)/3�/�� 4/0 dam, PERC RATE: MINIMUM SEPTIC TANK SIZE: MINIMUM LEACH FIELD SIZE: //38 Pfz . 3.2hP� G COMMENTS: �roposedielc� ias rad� P�cp�s,e �o II sv� w� }I i W UP+'i/ At1ri e � J1� • 4-r'n. �u%' mil% ✓dSN �✓/�iilFer �ty/��rJ N� cer f. ��jf �1 1,• PERC TE�T DONE Enviro;i4ienta rev. 6/90ks alth Officer DATE: `f //s/9, -74i r 0 � 0- �f0 X �106 //30 P Z Sh ��,Utars /� T/�rc�ts // 3 s, T1 Z �4",4 /8 rl z Y A,04--s //30 ,' 3 it x _t f e. I IT,t u ,I ... ... ..�.., .. •r '.I ! .... '.i... �T. .._ •: . c.. : J` �.. ... .. _ . I . .Y', }•'1.r:Yt'1:+... �';. a ENARTECH Inc. Consulting Engineers and Hydrologists August 18, 1992 Mr. Roger Boyd Eagle County Environmental Health Dept. //����\ P.O. Box 179 ,"\\E8 A05F1631 agle, CO RE: ISDS Permit No. 1133-92 Braunschmidt Residence Dear Roger: This letter is to certify that the Individual Sewage Disposal System for the Braunschmidt residence located at 220 Sam Grange Court (Lot #4, The Summit and Oak Ridge II Subdivision) has been constructed in accordance with the requirements of ISDS Permit No. 1133-92. The system installation contractor installed a 1250-gallon septic tank and 32 Infiltrator chambers in trenches. The construction meets all requirements. I inspected the system installation on August 14, 1992. Please give me a call if you have any questions. Sincerely, ENARTECH, INC. Peter Belau, P.E. PB/des cc: Ken Braunschmidt Joe Zamora P342-02 (P342_06A)92 23701 00 ►A 302 Eighth Street, Suite 325 P.O. Drawer 160 Glenwood Springs, Colorado 81602 (303) 945-2236 . 1133 — Lot 4, The Summit & Oak Ridge III, JOB Filing 3, Parcel # 2391-222-04-004 - - JOB NO. JOB LOCATION I LL TO 5��.V DATE STARTED 1 DATE COMPLE 7 DATE BILLED C�(OJJOA� e�m�n �� o� >r���,� �,� ;;� � peg z Q� Sr 2/ Gz r LPG f?a. Boll /6111 Ssv� ` -1'7 -4 2 is av fug Rpc- e s1iu� atfc rake ace 77EAIC ,s slem JOB COST SUMMARY r on m,��f ali� � u av� P� r�eei^ reyl�.{J �n�cer���ti i TOTAL SELLING PRICE raw, .See a//ach� �N n eer r �ru� ��m 5 TOTAL MATERIAL // RPM musj canor��f s1'te eval0. ISYI TOTAL LABOR r /,// /�4� G5? Rccen� m,� INSURANCE b � ..r l-F Iil �s/ Sf�� //�J IEE will b rP` outs, or ce►- � r SALES TAX &41 ra e, m a e an rlYllA'l SI kn MISC. COSTS TOTAL JOB COST GROSS PROFIT 4`T 4. TS LENS OF SELLING POVERHEAD RICE NET PROFIT JOB FOLDER Product 278 ®@ NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MASS. 01471 JOB FOLDER Printed in U.S.A.