HomeMy WebLinkAbout440 Mountain View Rd - 239122201003 - 1082-91ISINDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH P.O. Box 179 - 550 Broadway • Eagle, Colorado 81631 Telephone: 328-7311 or 949-5257 or 927-3823 YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT. NO. 1 O 82 Please call for final inspection before covering any portion of installed system. OWNER: Fritz and Lynn Fisher PHONE: 708-501-3766 MAILING ADDRESS: 874 Gordon Terrace AGENT: PHONE: SYSTEM LOCATION: Aspen Mountain View, Lot 9 Oak Ridge LICENSED INSTALLER: High Country Engineering LICENSE NO. (Eng. Design) DESIGN ENGINEER OF SYSTEM, INSTALLATION IS HEREBY GRANTED FOR THE FOLLOWING: 1000 GALLON SEPTIC TANK OR GALLON AERATED TREATMENT UNIT. DISPERSAL AREA REQUIREMENTS: SQUARE FEET OF SEEPAGE BED 600 SQUARE FEET OF TRENCH BOTTOM. SPECIAL REQUIREMENTS: Place inspection portals in seepage bed and distribution pipe. ENVIRONMENTAL HEALTH OFFICER: DATE: 10/1/91 or CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25.10.104, C.R.S. 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. SECTION Ill, 3.21 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED ACCORDING TO THE REGULATIONS. FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED' PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 0d SQUARE FEET. INSTALLED SEPTIC TANK: A� GALLONS DEGREES FEET SEPTIC TANK CLEANOUT TO WITHIN 8" OF FINAL GRADE, OR: \, PROPER MATERIALS AND ASSEMBLY / YES NO COMPLIANCE WITH COUNTY/STATE REGULATION REQUIREMENTS: YES NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. COMMENTS: r12or west - 'is e&1 6 Ti.M ,Be ci ENVIRONMENTAL HEALTH OFFICER: DATE: ENVIRONMENTAL HEALTH OFFICER: DATE: (RE -INSPECTION IF NECESSARY) RETAIN WITH RECEIPT RECORDS PERMIT APPLICANT/AGENT: OWNER: AMOUNT PAID: RECEIPT #: CHECK #: CASHIER: All Gard/e-, 163 ?c�- 13�3 ISDS Permit # Q 4 Building Permit # 4 9O APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE- EAGLE COUNTY P.O. BOX 179 EAGLE, CO 81631 328-8730/927-3823(Basalt) PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $125.00 PROPERTY OWNER: R 1?Z 4 t t SGt/Ee MAILING ADDRESS: %lI GD.e.DdIJ PHONE: -26?- �d� • 3'?tob APPLICANT/CONTACT PERSON: � or: LICENSED SYSTEMS CONTRACTOR: G� > ADDRESS:- 1k)Y�YCYtYC7kYrYyc . 9G3-i PHONE: ************************* PERMIT APPLICATION IS FOR: (X) NEW INSTALLATION ( ) ALTERATION ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description:.45P_e,� u 1,4)^/ t//EtAJ Su.1J)O/� Parcel Number: 0717 L Physical Address: BUILDING -TYPE : - - ( Check (X} Residential / ( } Residential / ( } Commercial / HOT TUB WATER CONSERVATION PLAN: TYPE OF WATER SUPPLY: Give depth of all :)t size: I. 939 ,4L applicable category) single Family Number of Bedrooms 13 Multi -Family* Number of Bedrooms Industrial* Type Yes { ).. No ,A Yes (X) No ( ) Well( ) Spring ( ) surface ( ) Public (X) Name of Supplier: wells within 200 feet of system: o *These systems require design by a Registered Professional Engineer NOTE: SITE PLAN MUST BE ATTACHED TO APPLICATION MAKE ALL REMIT ANC PAY L TO: "EAGLE COUNTY TREASURER" 7 SIGNATURE: Ciu S�ii''� p.� DATE AMOUNT PAID: RECEIPT# /l/ � DATE- 7- CHECK # 77T ' ''-/ CASHIER: TIME.LOG Travel Perc Final COMMUNITY DEVELOPMENT DEPARTMENT (303) 328-8730 EAGLE COUNTY, COLORADO October 1, 1991 Mr. and Mrs. Fisher C/o High County Engineering 923 Cooper Avenue Glenwood Springs, CO 81601 500 BROADWAY P.O. BOX 179 EAGLE, COLORADO 81631 FAX (303) 328-7207 RE: Issuance of Individual Sewage Disposal System Permit No. 1082 Dear Mr. and Mrs. Fisher: Enclosed is your ISDS Permit No. 1082. The enclosed copy of the permit must be posted at the installation site. You must call our office for final inspection before covering any portion of the installed system; the deadline for final inspections is December 1. If you have any questions, please feel free to contact us at the following numbers depending on your calling area: Eagle Valley 328-8730; Basalt/El Jebel 927-3823, ext. 730. Sincerely, Roger Boyd Environmental Health Assistant Community Development RB:ckc Enclosure cc: ISDS File COMMUNITY DEVELOPMENT DEPARTMENT (303) 32 8-87 30 EAGLE COUNTY, COLORADO November 15, 1991 Mr. and Mrs. Fisher c/o High Country Engineering 923 Cooper Avenue Glenwood Springs, CO 81601 RE: Final of ISDS Permit No. 1082 Dear Mr. and Mrs. Fisher: 725 CHAMBERS AVE. P.O. BOX 179 EAGLE, COLORADO 81631 FAX (303) 328-7207 This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to 'retain for your records. Also enclosed are informational sheets regarding the care of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division, P.O. Box 179, Eagle, Colorado 81631. We can also be reached, depending on your calling area, at the following numbers: Eagle Valley 328-8730; Basalt/El Jebel 927-3823. Sincerely, C. Kelley Carhart office Assistant ckc Encl: Information Sheets Final ISDS Permit cc: Chrono File ISDS File Building Permit File lov- October 29, 1991 Eagle, County Community Development P.O. Box 179 Eagle, CO 81631 Attn: Roger Boyd RE: Lot 9,, Oak Ridge I, Aspen Mountain View Subdivision Fisher Residence I.S.D.S. HCE Job No. 91010.`013 Dear Roger: On October 15, 1991, High Country Engineering, Inc. personnel observed the visible construction of the individual sewage disposal system at the Fisher residence. The; construction appeared to,be in conformance with the intent of the design. However, we instructed the contractor to install another observation pipe in the gravel between the distribution pipes. We also noted that a house' cleanout was not installed near the house wall (but we were told there was one inside), so we just told the contractor that the piping from the house to the septic tank should comply with the U.P.C. If you have any questions or need additional information, please give us a call. Sincerely, HIGH COUNTRY ENGINEERING, INC. Timo by P. Beck, P.E. Prin ipal Engineer TPB:rjm cc: Stasmore, Inc. RECEIVED p CT 3 1 i991 EAGLE COUNTY COMMUNITY DEVELOPMENT 923 Cooper Avenue Glenwood Springs, CO 81601 Telephone:, 303-945-8676 303-920-3669 • FAX: 303-945-2555 1 .t if t4 NO 93 q f ■ + ate) ,. :w.* 1082 JOB NA Fritz & Lynn Fisher JOB N(:� Q , Lot 9, Oak Ridge Aspen Mnt. View r777ION BILL TO DATE STARTED DATE COMPLETED DATE BILLED JOB COST SUMMARY TOTAL SELLING PRICE TOTAL MATERIAL TOTAL LABOR INSURANCE SALES TAX MISC. COSTS TOTAL JOB COST GROSS PROFIT LESS OVERHEAD COSTS % OF SELLING PRICE NET PROFIT JOB FOLDER Product276 Q® NEW ENGLAND BUSINESS SERVICE, ING., GROTON, MA 01471 JOB FOLDER Printed in US.A LOT 10 GRAPHIC SCA] 30 0 15 30 60 ( IN FEET ) 1 inch = 30 ft. � ;� -- ; ,120 —° ��- .� ��II � r'; % �;, ;; � �s '� -;ter=�y• � /�"j� " ` \ it ho �'�-- /`✓/�l�;`J /r/ .' ( 11- //� \ i - � I� �'�tr ��i�� �j/J��.r1, �1'`\� -7 %l ' ��1I!1 I{',` C) J 1, 0 \1 6610,0 �0 1 I •, V �� I ;•, o `� ? �\•` -6429 6540 Tank VICINI T Y MAP, D !i \I LOT 8 44 A IN FROM SEPTIC TANK 1 •— 3• MIN. MAX 1. 3• PERFORATED 4.0 PIPE (TYP.) GENERAL BED CROSS SECTION NOTES BED PLAN N.T.S. I FILTER FABRIC, OR 4' (MIN.) STRAW OR MARSH HAY i.� 6' — (TYP. BETWEEN PIPES) i 1/2' SCREENED ROCK SECTION A -A N.T.S. 1. BED LENGTH SHALL NOT EXCEED 100 FEET. 2. THE BOTTOM OF THE BED SHALL BE LEVEL. 3. FOR EACH SIX (6) FEET, OR PART THEREOF, IN BED WIDTH, THERE SHALL BE ONE DISPOSAL LINE EXTENDING THE LENGTH OF THE BED. 4. DRAINAGE DITCHES ARE TO BE PROVIDED AROUND BED, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING FIELD AREA. GENERAL NOTES 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE EAGLE COUNTY REGULATIONS OF INDIVIDUAL SEWAGE DISPOSAL SYSTEMS, EVEN THOUGH ALL SUCH REQUIREMENTS ARE NOT SPECIFICALLY. NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE —MENTIONED REGULATIONS. 2. SEE ACCOMPANYING CALCULATIONS FOR FIELD SIZING. 3. CLEANOUTS ARE REQUIRED AT ALL BENDS AND AT LEAST EVERY 100 FEET ALONG THE HOUSE SEWER. MINIMUM SLOPE IS 1/4" PER FOOT. 4. THE CONTRACTOR SHALL BE RESPONSIBLE_ FOR INSTALLING ALL COMPONENTS OF THIS SYTEM WATER TIGHT (UP TO THE FIELD) TO PREVENT INFILTRATION. 5. TOPSOIL COVER MAY BE VARIED (WITH 1—FOOT MINIMUM) TO ALLOW LANDSCAPING. 6. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS POINTS TO WITHIN 1-2—FOOT OF FINAL GRADE. "CATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL t-1INIMUM DISTANCES, AND SlLCPES MEET THOSE REQUIRED. I i o O O o� O p s' (TYP.) 1 I.S.D.S. DESIGN 3—BEDROOM HOME USE (20'MIN/INCH PERC RATE (PER PERC TEST PERFORMED BY HCE PERSONNEL ON 9/12/91). AVERAGE FLOW: 3—BR * 2 PEPS/BR * 75 GAL/PERS PER DAY = 450 GAL/DAY DESIGN FLOW: 1.5 (AVE) = 675 GAL/DAY SEPTIC TANK REQUIRED IS 1000 GAL. TYPICAL ABSORPTION BED: z AREA REQ' D . = Q/5 f t = 675/5 J 20 600 FTz OF TRENCH BOTTOM 780 FT OF BED AREA (*1.3 FOR BED VS. TRENCH) q4-1 R` j 793 RECOMMEND 18' X 44' BED, OR 24' X 34' BED, W/LONG DIMENSION PARALLEL TO CONTOURS. Fr�� SEE DRAWING FOR TYPICAL PLAN, SECTION, .-ND L,0 [ Is0-5 4I08,2 r- r-- — T- N 0. ' DATE i--- -- REV!SIONI BY F'SCHER RESIDENCE EL JEBEL, COLORADO �r SAL SEWAGE SYSTEM LOT 9, OAK RIDGE ONE, ASPEN MOUNTAIN VIEW SUBDIVISION HIGH COUNTRY ENGINEERING, INC. 923 COOPER AVENUE - I FILE N 0. ! T GLENWOOD SPRINGS, CO 81601 DES. TPB I CK. SHEET 1 (303) 945-8676 r -- DR. HMS ( DATE 9/24/91 1 91 010.013 1 OF 1