Loading...
HomeMy WebLinkAbout417 Toner Creek Rd - 246703401003INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH P.O. Box 179 - 550 Broadway • Eagle, Colorado 81631 Telephone: 328-7311 or 949-5257 or 927-3823 Q YELLOW COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 9 S 6 Please call for final inspection before covering any portion of installed system. OWNER: John Brennan I PHa�8-234-1420 MAILING ADDRESS: 290 Woodland Rd, Lake Forest, IL 60045 AGENT: PHONE: SYSTEM LOCATION: 0442 Toner Creek, Basalt, Lot 13 LICENSED INSTALLER: Ed Draeger/D Plus FntPrn�ri ps LICENSE NO. DESIGN ENGINEER OF SYSTEM, INSTALLATION IS HEREBY GRANTED FOR THE FOLLOWING: 1250 GALLON SEPTIC TANK OR GALLON AERATED TREATMENT UNIT. DISPERSAL AREA REQUIREMENTS: SQUARE FEET OF SEEPAGE BED 600 SQUARE FEET OF TRENCH BOTTOM. or 200 lineal ft of 1011 SB2 SPECIAL REQUIREMENTS: Place inspection portals at end of each trench ENVIRONMENTAL HEALTH OFFICER: DATE: L CONDITIONS: lo 1. ALL INSTALLATI S MUST COMPLY WITH ALL REQUIRKENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, C.R.S. 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT AND CAUSE FOR BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. SECTION 111, 3.21 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED ACCORDING TO THE REGULATIONS. FINAL APPROVAL OF SYSTEM: (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED' PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: � 0 SQUARE FEET. ? �j>k INSTALLED SEPTIC TANK: C" yQGALLONS DEGREES FEETV` SEPTIC TANK CLEANOUT TO WITHIN 8" OF FINAL GRADE, OR: �( PROPER MATERIALS AND ASSEMBLY YES NO COMPLIANCE WITH COUNTY/STATE REGULATION REQUIREMENTS: YES NO ANY ITEM CHECKED NO REQUIRES CORRECTION BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. COMMENTS: ENVIRONMENTAL HEALTH OFFICER: DATE: / ENVIRONMENTAL HEALTH OFFICER: DATE: (RE -INSPECTION IF NECESSARY) RETAIN WITH RECEIPT RECORDS PERMIT APPLICANT/AGENT: OWNER: AMOUNT PAID: RECEIPT #: CHECK M CASHIER: APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE EAGLE COUNTY Number: 838 P. 0. BOX 179 P �l5 Zz EAGLE, COLORADO 81631 949-5257 Vail 328-7311 Eagle 927-3823 Basalt PERMIT APPLICATION FEE $150.00 I PERCOLATION_TEST FEE $125.00 NAME OF OWNER: �OHA) kbUN6J MAILING ADDRESS: 2qo W Qofl PHONE: 709—ZA—(y?-V NAME OF APPLICANT (If different from owner): ADDRESS: DESIGN ENGINEER OF SYSTEM (If applicable): PHONE: ADDRESS: PHONE: PERSON RESPONSIBLE FOR INSTALLA ION OF SYSTEM:,E® PgAt- tp_ {S Q�EA_)c2 P is6s LICENSED INSTALLER: ( V YES ( ) NO ADDRESS: 00�(-f-D�rr_S LA ► 1+5da Cn PHONE: 72L39z( PERMIT APPLICATION IS FOR: O NEW INSTALLATION ( ) ALTERATION ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAAt SEWAGE DISPOSAL SYSTEM: Physical Address: 2-q—�A1�'72 Ci�C�u K V3 Ks�t— AST cof Parcel Number: L� 13 Lot Size: 41.35 fe Legal Description: J1% SE%q Q Cei 13 dT 5t6, 3 TNSItiP�S- BUILDING OR SERVICE TYPE (Check applicable category): Residential - Single Family ( ) Residential- Fourplex ( Residential - Duplex ( ) Commercial (Type) ( ) Residential - Triplex NUMBER OF PERSONS: Ll NUMBER OF BEDROOMS: _r WASTE TYPES Check applicable categories): Commercial or Institutional Dwelling ( ) Non -Domestic Wastes ( ) Transient Use ( ) Garbage Disposal ( ) Dishwasher ( ) Automatic Washer ( ) Spa Tub ( ) Other (Specify): TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: Septic Tank Composting Toilet ( ) Incineration Toilet ( ) Vault Privy ( ) Greywater ( ) Chemical Toilet ( ) Pit Privy ( ) Aeration Plant ( ) Recycling, Portable Use ( ) Other ( ) Recycling, Other Use WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE: ( ) YES (X) NO IS SYSTEM DESIGNED FOR LESS THAN 2,000 GALLONS PER DAY: YES ( ) NO WATER CONSERVATION PLAN: ( ) YES (X) NO NOTE: The Environmental Health Office may reduce the required absorption area upon approval of an adequate water conservation plan. SOURCE AND TYPE OF WATER SUPPLY: ( ) Well (�j Spring ( ) Creek/Stream Give depth of all wells within ,200 feet of Jsy tem: NDiUL If supplied by community water, give name of supplier: SIGNATURE: 1�1 DATE: INFORMATION BELOW TO BE FILLED OUT BY ENVIRONMENTAL HEALTH OFFICER: GROUND CONDITIONS: Percent ground slope Depth to Bedrock (Per 8' profile hole Depth to Groundwater table TEST RESULTS: Minutes per inch in Hole #1 Minutes per inch in Hole #2 Minutes per inch in Hole #3 FINAL DISPOSAL BY: ( Absorption Trench, Bed or ( ) Above Ground Dispersal ( ) Under Grou�gd Dispersal Other . I-' PAID:V RECEIPT rurry SOIL PERCOLATION Pit ( ) Evapotranspiration ( ) Sand Filter ( ) Wastewater Pond 31 NOTE: SITE PLAN MUST BE ATTACHED TO APPLICATION. MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER". V (Environmental Health Dept. - Rev. 4/88) l EAGLE COUNTY 551 Broadway Eagle, Colorado 81631 (303) 328 7311 Date: June 25, 1990 John Brennan 290 Woodland Rd. Lake Forest, IL 60045 Re: Issuance of Individual Sewage Disposal System Permit No.986 Enclosed is your ISDS Permit No. 986 This copy of the permit must be posted on the installation site. You must call our office for final inspection before covering any portion of the installed system. If you have any questions, please feel free to contact us at the following numbers for your calling area: Vail/Avon 949-5257; Basalt/El Jebel 927-3823; Eagle area 328-8730. Sincerely, Ravm Envi. xc: ISDS file cer Board of County Commissioners Assessor Clerk and Recorder Sheriff Treasurer P.O. Box 850 P.O. Box 449 P.O. Box 537 P.O. Box 359 P.O. Box 479 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 COMMUNITY DEVELOPMENT DEPARTMENT (303) 328.8730 EAGLE COUNTY, COLORADO July 19, 1991 Mr. John Brennan 290 Woodland Rd Lake Forest, IL 60045 RE: Final of ISDS Permit No. 986 Dear Mr. Brennan: 725 CHAMBERS AVE. P.O. BOX 179 EAGLE, COLORADO 81631 FAX (303) 328.7207 This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. Also enclosed are informational sheets regarding the care of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division, P.O. Box 179, Eagle, Colorado 81631. We can also be reached, depending on your calling area, at the following numbers: Eagle valley 328-8730; Basalt/El Jebel 927-3823. Sincerely, RaymonMerry, %.E.H Environmental Healficer RPM:ckc Encl: Informational Sheets Final ISDS Permit cc: Chrono File T2S-'DS" FRiIF Building Permit File ROUTE FORM � EAGLE COUNTY ENVIRONMENTAL HEALTH OFFICE PiAAA D Name "�dsgLL+ 3-I Date Routed U Z P—r 0reek L)J - Application No. Location Please review the attached Individual Sewage Disposal System Permit Application and return it with this completed form the the Environmental Health Office. PLANNING: Complies with - YES NO REVIEWED BY DATE Subdivision Regulations: Zoning Regulations: Recommend Approval: COMMENTS: BUILDING: Complies with - Building Permit Applied For: Building Permit Issued: Recommend. Approval: COMMENTS: ENGINEER: Complies with - Roads: Grading: Drainage: Recommend Approval: COMMENTS: YES NO REVIEWED BY DATE YES NO REVIEWED BY DATE ENVIRONMENTAL HEALTH: Complies with - YES Floodplain Permit Necessary: I.S.D.S. Regs. Compliance: Recommend Approval: COMMENTS: NO REVIEWED BY TE O Chen NorthermInc. Consulting Engineers and Scientists - # FOR FOUNDATION DESIGN --•-•.E• RESIDENCE TONER CREEK ROAD I �• •• • .100 •• 5080 Road 154 Glenwood Springs, Colorado 81601 303 945-7458 303 945-2363 Facsimile Prepared For: John Brennan 290 Woodland Road Lake Forest IL 60045 Job No. 4 271 90 April 27, 1990 A member of the IIIII group of companies CONCLUSIONS PURPOSE AND SCOPE OF STUDY PROPOSED CONSTRUCTION SITE CONDITIONS FIELD EXPLORATION SUBSOIL CONDITIONS FOUNDATION RECOMMENDATIONS FLOOR SLABS UNDERDRAIN SYSTEM SURFACE DRAINAGE LTTATIONS FIGURE 1 - LOCATION OF EXPLORATORY PITS AND PERCOLATION TEST HOLES FIGURE 2 - LOGS OF EXPLORATORY PITS FIGURE 3 - LEGEND AND NOTES FIGURE 4 - GRADATION TEST RESULTS TABLE I - PERCOLATION TEST RESULTS 1 1 2 2 3 4 4 5 6 7 7 'sue Il ;�C✓.. P _..- l ''L�i t?. _..�.i. :.1 :. .. , L_ F L CONCLUSIONS The proposed residence should be founded with spread footings bearing on the natural granular soils below all topsoil and designed for an allowable soil bearing pressure of 1500 psf. Other design and construction criteria relating to geotechnical aspects of the proposed residence are presented in the body of the report. PURPOSE AND SCOPE OF STUDY This report presents the results of a subsoil study for a proposed residence located on Toner creek Road, about one mile north of the Frying Pan River, Eagle County, Colorado. The project site is shown on Fig. 1. The study was conducted in accordance with our agreement for geotechnical engineering services letter to John Brennan, dated March 7, 1990. A field exploration program consisting of exploratory pits was conducted to obtain information on subsurface conditions. Samples obtained during the field exploration were tested in the laboratory to determine their engineering characteristics. The results of the field exploration and laboratory testing were analyzed to develop recommendations for foundation types, depths and allowable pressures for the proposed building foundation. The results of the field exploration and laboratory testing are presented in the report. This report has been prepared to summarize the data obtained during this study and to present our conclusions and recommendations based on the proposed construction and the subsoil conditions encountered. Design parameters and a discussion of geotechnical engineering considerations related to construction of the proposed residence are included in the report. FChen"tNorthern, Inc. �- ic: c - ...,:Isis F L -2- PROPOSED CONSTRUCTION The proposed residence will be a one to two-story wood frame structure attached to the existing structure. Ground floor will be either slab -on -grade or structural aver crawl space. Grading for the structure is expected to be L relatively minor with cut depths between about 5 to 6 feet. We assume relatively light foundation loadings, typical of the proposed type construction. The proposed leach field area is located about 100 feet south of the proposed L building area. If building loadings, location or grading plans change significantly from those described above, we should be notified to reevaluate the recommendations Lcontained in this report. FSITE CONDITIONS The site is occupied by an existing single story, wood frame house founded on six sonatube piers . The house is new and appears to be still under con- struction. The proposed � p posed building area is located directly south of the existing house. The grading of the site is natural with a recent 1 to 2-foot deep cut L for a driveway to the west of the building area. A culvert and driveway fill Chad recently been installed over Toner Creek to the west of the building area. An existing irrigation ditch is located upslope and to the east of the proposed f building area. The topography of the site slopes steeply down from the L irrigation ditch to the building area at grades of about 50%. The site then slopes more moderately at grades of about 15% down to the southwest towards Toner Creek. There are steep cut banks located along Toner Creek on the west side of the property. The proposed leachfield area located P P�� to the south of the building area, slopes down to the southwest with grades of about 12%. Vegetation at the site consists of oak brush, aspen and fir trees with an F - Cher, Northern, ne. F -3- understory of grass and weeds. The area of the proposed leach field has a heavy cover of oak brush. Scattered basalt cobbles and boulders were observed on the ground surface at the site. A red sandstone outcrop of the Triassic Age State Bridge Formation was observed to the west of, and several hundred feet higher, than the site. The outcrop is on the opposite side of the creek and road from the house site. The site could be impacted by rockfall from this source. The rockfall hazard was not analyzed as part of this study. The property is marked as a rockfall area on the Environmental and Geologic Constraints Map prepared for the Colorado Geological Survey by F.M. Fox and Associates, Inc. in 1974. Due to the road and creek located between the subject site and the rock outcrop, and the lack of red sandstone boulders on the surface of the site, the rockfall hazard in the proposed building area can be regarded as low. The field exploration for the project was conducted on March 29, 1990. Two exploratory pits were excavated at the locations shown on Fig. 1 to evaluate the subsurface conditions. The pits were excavated with a rubber -tired backhoe. The pits were logged by a representative of Chen Northern, Inc. Due to the heavy cover of oak brush in the proposed leach field area, access was not possible at the time of our initial site visit. An 8-foot deep profile pit and three 3-foot deep percolation test pits were excavated on April 5, 1990 by Ram Excavating. A 1-foot diameter by 1-foot deep hole was dug at the bottom of each of the percolation pits and the holes were soaked on April 5. The percolation tests were performed by Chen Northern on April 6, 1990. The percolation test results averaged about 10 minutes per inch. The F L F111-- 1 .�" (w L�t'� -4- Fpercolation test results are shown on Table I. A graphic log of the subsoils encountered in the leach field profile pit is shown on Fig. 2. SUBSOIL CONDITIONS The subsoil conditions encountered at the site are shown graphically on Fig. 2. The subsoils consist of about 1 1/2 feet of topsoil overlying medium dense, silty to clayey gravelly sands containing cobbles and boulders. The soil appears to be a colluvial deposit resulting from erosion of the hillside above the property. These type soils characteristically have tendencies to settle when wetted under loading. Laboratory testing performed on samples obtained from the exploratory pits consisted of natural moisture content, gradation analyses and Atterberg limits. Results of a gradation analysis performed on a sample of the coarse granular soils are shown on Fig. 4. Atterberg limits testing indicates that the clay fraction of the subsoils is of low plasticity. No free water was encountered in the pits at the time of excavation and the subsoils were generally moist. FFOUNDATION REOATIONS CConsidering the subsoil conditions encountered in the exploratory pits and the nature of the proposed construction, we recommend the building be founded f with spread footings bearing on the natural soils. The design and construction criteria presented below should be observed for a spread footing foundation system. The construction criteria should be Cconsidered when preparing project documents. 1) Footings placed on the undisturbed natural soils should be designed for an allowable soil bearing pressure of 1500 psf. Based on experience, we expect initial settlement of footings designed and constructed as -5- Ldiscussed in this section will be about 1 inch or less. There could be additional settlement due to wetting of the foundation soils. 2) All existing fill, topsoil and any loose or disturbed soils should be removed and the footing bearing level extended down to the natural subsoils. 3) The footings should have a minimum width of 16 inches for continuous walls and 2 feet for isolated pads. 4) Exterior footings and footings beneath unheated areas should be provided with adequate soil cover above their bearing elevation for frost protection. Placement of foundations at least 42 inches below exterior grade is typically used in this area. 5) Continuous foundation walls should be reinforced top and bottom to span an unsupported length of at least 12 feet. Foundation walls acting as retaining structures should also be designed to resist a lateral earth pressure corre sponding esponduzg to an equivalent fluid unit weight of 45 pcf. 6) A representative of the soil engineer should observe all footing excavations prior to concrete placement to evaluate bearing conditions. L I7 FfMR SLABS L_ The natural on -site soils, exclusive of topsoil, are suitable to support lightly to moderately loaded slab -On -grade construction. To reduce the effects of some differential movement, floor slabs should be separated from all bearing walls and columns with expansion joints which allow unrestrained vertical movement. Floor slab control joints should be used to reduce damage due to shrinkage cracking. The requirements for joint spacing and slab reinforcement (� should be established by the designer based on experience and the intended slab l use. A minimum 4-inch layer of free -draining gravel should be placed beneath LJ FC, lheni@- No i-Lhern, !,-Ic. basement level slabs to facilitate drainage. This material should consist of minus 2-inch aggregate with less than 50% passing the No. 4 sieve and less than 2% passing the No. 200 sieve. All fill materials for support of floor slabs should be compacted to at least 95% of maximum standard Proctor density at a moisture content near optimum. Required fill can consist of the on -site gravels devoid of vegetation, topsoil and oversized rock. D21'0- Although free water was not encountered during our exploration, it has been our experience in mountainous areas that local perched groundwater may develop during times of heavy precipitation or seasonal runoff. Frozen ground during spring runoff can create a perched condition. We recommend below grade construction, such as retaining walls, crawl space and basement areas be protected from wetting and hydrostatic pressure buildup by an underdrain system. The drains should consist of drain tile placed in the bottom of the wall backfill surrounded above the invert level with free -draining granular material. The drain should be placed at least 1 foot below lowest adjacent finish grade and sloped at a minimum 1% to a suitable gravity outlet. Free -draining granular material used in the underdrain system should contain less than 2% passing the No. 200 sieve, less than 50% passing the No. 4 sieve and have a maximum size of 2 inches. The drain gravel backfill should be at least 2 feet deep. An impervious liner such as 20 mil PVC should be provided beneath the drain gravel in a trough shape and attached to the foundation wall with mastic to prevent wetting of the foundation soils. FCheAO'Northtern, Inc. -7- F The following drainage precautions should be observed during construction and maintained at all times after the residence has been completed: 1) Inundation of the foundation excavations and underslab areas should be avoided during construction. 2) Exterior backfill should be adjusted to near optimum moisture and compacted to at least 95% of the maximum standard Proctor density in pavement and slab areas and to at least 90% of the maximum standard Proctor density in landscape areas. 3) The ground surface surrounding the exterior of the building should be sloped to drain away from the foundation in all directions. We reccmme-nd a minimum slope of 12 inches in the first 10 feet in unpaved areas and a F 4, F L_ minimum slope of 3 inches in the first 10 feet in paved areas. Free -- draining wall backfill should be capped with about 2 feet of the on -site soils to reduce surface water infiltration. Roof downspouts and drains should discharge well beyond the limits of all backfill. 5) Iandscaping which requires regular watering, such as sod, should not be located within 10 feet of the building to help limit subsurface wetting. I=ATIONS This report has been prepared in accordance with generally accepted soil and foundation engineering practices in this area for use by the client for design purposes. The conclusions and recommendations submitted in this report are based upon the data obtained from the exploratory pits excavated at the locations indicated on Fig. 1 and the proposed type of construction. The nature and extent of subsurface variations across the site may not become evident until r excavation is performed. If during construction, fill, soil, rock or water conditions appear to be different from those described herein, this office should be advised at once so reevaluation of the recommendations may be made. We reconmend on -site observation of excavations and foundation bearing strata and testing of structural fill by a representative of the soil engineer. Sincerely, CEiIN-NORIHEE2N, INC. OIREBy.C/�HHiH �9 • • Hardin Daniel E. Hain P.E. = : oQ 2 • ' - 24443 s S • i • Reviewed By Steven L. Pawlak, P.E. DEH/ec �J 3/4 MILE SOUTH TO FRYING PAN RIVER Iro iZ° \ I TONER \ G-) CREEK / ✓ too ' 1 � \ o \ PIT I \0 \ \ I I � PROPOSEI BUILDING I I f ■ I\PIT 2 \ (to 1 \ \` PROFILE PIT\ \ \ ■ \\PI p\ \ P 2p\ \ p� P3 \ � duo OVERHEAD POWER LINE PROPERTY BOUNDARIES APPROXIMATE SCALE I If = 401 4 271 90 I ChenNorthern,Inc. I LOCATION OF EXPLORATORY PITS AND I Fig. PERCOLATION TEST HOLES I Pit 1 Pit 2 Profile -Pit Elev. = 1121 Elev. = 10711 Elev. = 1041 115 115 110 .: 110 l.l. �• L.L I 0 105 :Qo 105 I 0 � _p• b Combined Sample d w Lab Testing: n �- 0: LLI WC = 10 100 +4=25 100 -200=29 LL = 25 PI = g .a: 95 95 Note: Explanation of symbols presented on Fig. 3 4 271 90 ChenONorthernjI -C- Logs of Exploratory Pitts Fig. 2 FLEGEND- r F F F f F F F F F f E F F MTopsoil, organic silt, clayey, with roots, soft, moist, black. Gravel (GC); very sandy, clayey, with cobbles and boulders, medium dense, moist, b red, colluvium. Small disturbed bulk sample. NOTES: 1. Exploratory pits 1 and 2 were excavated on March,29, 1990. .Percolation and.. profile pits were excavated on April: 5, 1990. Percolation tests were performed on April 6, 1990. 2. Locations of exploratory pits were measured approximately by pacing from features shown on the site plan provided. 3. Elevations of exploratory pits were obtained by interpolation between contours on the site plan provided. 4. The exploratory pit locations and elevations should be considered accurate only to the degree implied by.the method used. 5. The lines between materials shown on the explroatory pit logs represent the approximate boundaries between material types and tansitions may be gradual. 6. No free water was encountered in the pits at the time of excavation. Fluctuation in water level may occur with time. 7. Laboratory Testing Results: WC = Water Content (%) +4 = Percent retained on No. 4 sieve -200 = Percent passing No. 200 sieve LL = Liquid Limit (%) PI = Plasticity Index (%) 1 4 271 90 1 Chen@Northern,InC. I . Legend and Notes I Fig. 3 1 HYDROMETER ANALYSIS SIEVE ANALYSIS am 1 11 1 11 1 1 . 1 / . • 1 SIEVE ANALYSIS 1 1 MBE 1 1• 0 MEMO 1 1 •1 1 QCC� C� /�r>_rrrrlrr>•�rr�a_ TABLE I 4 271 90 PERCOLATION TEST RESULTS April 6, 1990 DEPTH TO DEPTH TO LENGTH WATER WATER AVERAGE HOLE OF AT START AT END DROP IN PERCOLATION HOLE DEPTH INTERVAL OF INTERVAL OF INTERVAL WATER LEVEL RATE NO. (In.) (Min.) (Inches) (Inches) (Inches) (Min./Inch) P-1 12 5 2 3/4 4 1 1/4 4 4 /12 1/2 4 1/2 5 1/2 5 5 3/4 3/4 5 3/4 6 /14 1/2 Water added 3 3 3/4 3/4 3 3/4 4 1/4 1/2 4 1/4 4 3/4 1/2 4 3/4 5 1/4 5 5 1/2 1/2 5 1/2 6 1/2 10 P-2 14 5 4 5 1/4 1 1/4 5 1/4 5 3/4 1/2 5 3/4 6 1/2 3/4 6 1/2 7 1/2 7 7 1/2 1/2 Water added 4 4 3/4 3/4 4 3/4 5 1/2 3/4 5 1/2 6 1/2 6 6 1/2 1/2 6 1/2 7 1/2 7 7 1/2 1/2 10 P-3 15 5 4 5 1/4 1 1/4 5 1/4 6 3/4 6 6 1/2 1/2 6 1/2 7 1/2 7 7 3/4 3/4 Water added 5 5 3/4 3/4 5 3/4 6 1/4 1/2 6 1/4 6 3/4 1/2 6 3/4 7 1/4 1/2 7 1/4 7 3/4 1/2 7 3/4 8 1/4 1/2 10 986 Brennan Lot 13 0442 Toner JOB NAME Creek Basalt JOB NO. JOB LOCATION BILL TO DATE STARTED DATE COMPLETED DATE BILLED JOB COST SUMMARY TOTAL SELLING PRICE TOTAL MATERIAL TOTAL LABOR INSURANCE SALES TAX MISC. COSTS TOTAL JOB COST GROSS PROFIT LESS OVERHEAD COSTS % OF SELLING PRICE NET PROFIT JOB FOLDER PrOdUCt 278 jg�g?® NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MA 01471 JOB.FOLDER Printed in,U.S.A. 2 _-..r �� ' i 711f1 -/r�� 711 Af AiN 4low ;, IUi HRttOino� Zy 71�g/�/