HomeMy WebLinkAbout743 Willits Ln - 246503400035 - 0887ISINDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
Eagle County Department of .Environmental Health PERMIT N2 0887
P.O. Box 850 - 550 Broadway
Eagle, Colorado 81631
Telephone: 328-7311 or 949-5257 or 927-3823
YELLOW COPY OF PERMIT MUST PLEASE CALL FOR FINAL INSPECTION BEFORE
BE POSTED AT INSTALLATION SITE COVERING ANY PORTION OF INSTALLED SYSTEM
Owner: Theodore Guy and Susann Siebert Guy Telephone: 927-3167
Address: P • 0. Box 1467 Basalt, Colorado 81621
System Location:
-Lieensed Installer
LicMANumbe(S
Conditional installation approval is hereby granted for the following: �� I SUP HiL�
Minimum requirements:. C500 Gallon Septic Tank orM/4 Aerated Treatment unit 66'_V"4_a
Absorption area of dispersal area computed as follows:
Percolation rate: Inch in Minutes
Absorption area per bedroom Sq. Ft.
Number of Bedrooms X Sq. Ft. minimum requirement per bedroom -
equals Total Sq. Ft. minimum requirement
Special Requirements: To be installed as per engineered design.
Date: October 20, 1988 Fnvironmental Health Officer:
CONDITIONS:
1. All installations must comply with all requirements of the Eagle County Individual Sewage Disposal System
Regulations, adopted pursuant to authority granted in 25-10-104, C.R.S. 1973, as amended.
2. This permit is valid only for connection to structures which have fully complied with County zoning and building
requirements. Connection to or use with any dwelling or structure not approved by the zoning and building
departments shall automatically be a violation of a requirement of the permit and cause for both legal action and
revocation of the permit.
3. Section III, 3.21 requires any person who constructs, alters or installs an Individual Sewage Disposal System to
be licensed according to the regulations.
FINAL APPROVAL OF SYSTEM:
No system shall be deemed to be in compliance with the Eagle County Individual Sewage Disposal System
Regulations until the system is approved prior to covering any portion of the system.
(GlC37
INSTALLED ABSORPTION OR DISPERSAL AREA: 2 SQ. FT.
INSTALLED SEPTIC TANK: 1000 GALLONS; 1150 DEGREES; 34 FEET
DESIGN ENGINEER OF SYSTEM: 5 cA m vesee— Go 2 oay - f44ce.
INSTALLER OF SYSTEM: PHONE:
SEPTIC TANK CLEANOUT TO WITHIN 12"OF FINAL GRADE OR
AERATED ACCESS PORTS ABOVE GRADE: YES ".NO
PROPER MATERIALS AND ASSEMBLY: YES �_ NO
COMPLIANCE WITH PERMIT REQUIREMENTS: YESNO
COMPLIANCE WITH COUNTY / STATE REGULATION REQUIREMENTS: YES NO
COMMENTS:
(Any item checked NO requires correction before final approval of system is made. Arrange a re -inspection when
work is completed.)
DATE (Final Approval) ©ENVIRONMENTAL HEALTH OFFICER:
DATE (Re4nspection) ENVIRONMENTAL HEALTH OFFICER:
RETAIN WITH RECEIPT RECORDS PERMIT
Name of Applicant: Theodore Guy Name of Owner: Same
Amount Paid: $275.00 Receipt Number: 1216 Date: 7-20-88 Cashier: JB
Check # 175
White and Pink Copies - Environmental Health Department Yellow Copy - Applicant / Owner
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY No. E f - 113
P. O. BOX 179
EAGLE, COLORADO 81631
949-5257 Vail 328-7311 Eagle 927-3823 Basalt
PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $125.00
NAME OF OWNER: Tjj =1DQCg— sr5mgr clu. r
MAILING ADDRESS: t2f>x wo-�A4�`� PHONE:
NAME OF APPLICANT (If different from owner):
ADDRESS:
DESIGN ENGINEER OF SYSTEM (If applicable):
ADDRESS:
PERSON RESPONSIBLE FOR INSTALLATION OF SYSTEM:
LICENSED INSTALLER: ( ) YES ( ) NO
ADDRESS:
PHONE:
PHONE:
PHONE:
PERMIT APPLICATION IS FOR: (4 NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Physical Address: ne,
Parcel Number: Lot Size:
Legal Description: e;,er—, p%�.
BUILDING OR SERVICE TYPE (Check applicable category):
Residential - Single Family ( ) Residential - Fourplex
( ) Residential - Duplex ( ) Commercial (Type)
( ). Residential - Triplex
NUMBER OF PERSONS: /L NUMBER OF BEDROOMS:
WASTE TYPES Check applicable categories
Commercial or Institutional Dwelling
( ) Non -Domestic Wastes ( ) Transient Use
( ) Garbage Disposal ( ) Dishwasher
(/) Automatic Washer ( ) Spa Tub
( ) Other (Specify):
TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED:
Septic Tank Composting Toilet ( ) Incineration Toilet
( ) Vault Privy ( ) Greywater ( ) Chemical Toilet
( ) Pit Privy ( ) Aeration Plant ( ) Recycling, Portable Use
( ) Other ( ) Recycling, Other Use
WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE: ( ) YES (} NO
IS SYSTEM DESIGNED FOR LESS THAN 2,000 GALLONS PER DAY: YES ( ) NO
WATER CONSERVATION PLAN: ( ) YES ( ) NO
NOTE: The Environmental Health Office may reduce the required absorption area upon
approval of an adequate water conservation plan.
SOURCE AND TYPE OF WATER SUPPLY: O Well ( ) Spring ( ) Creek/Stream
Give depth of all wells within 200 feet of system:
If supplied by communit water give name of supplier:
SIGANTURE: j DATE: 7r-.o• 8
INFORMATION BELOW TO BE FILLED OUT BY �1M RONMENTAL HEALTH OFFICER:
GROUND CONDITIONS: Percent ground slope ,� u 2 k
Depth to Bedrock (Per 8' profile hole)7
Depth to Groundwater table f/L ' 6Aj -7-z.Z-80
SOIL PERCOLATION TEST RESULTS: Minutes per inch in Hole #1
FINAL DISPOSAL BY:
( Absorption Trench, Bed or
( } Above Ground Dispersal
( ) Under Ground Dispersal
( ) Oth A
r
AMOUNT PAID: !` RECEIPT
Minutes per inch in Hole #2
Minutes per inch in Hole #3
Pit ( ) Evapotranspiration
( ) Sand Filter
( ) Wastewater Pond
NUMBER /oM DATE:.
NOTE: SITE PLAN MUST BE ATTACHED TO APPLICATION.
(Environmental Health Dept. - Rev. 4/88)
1
li
PERCOLATIONi 1-EST
ENVIRONIMENTAL HEALTH CEPARTMENT
Eagle Count/
FEE: $125.00
ISDS APPLICATION NO.
OWNER:-
LEGAL DESCRIPTION:
RURAL ADDRESS:
TYPE OF DUELLING: S10GU ,, NUMBER OF BEDROOMS:
DATE OF PERCOLATION TEST: -7- Z 1-a3
TEST HOLES PRE-SOAKED: YES X
TYPE OF SOIL: 5--1N0 cl 6,2Aue,,j
NO Mcr�,-rij 1,?AJel
TII•'E II WATER DEPTH II IIJC ?ES OF FALL
1 1 2 3 +� l RATE
2 3 1 1 2 3 �I 1 ;
3/4:11,111,11,
-
3',
II I II / 21 3 I I II
i�. II I I II
it I 1 II I - 1 II
PERCOLATION RATE:
RECO, MMEiNDED MINIMUM SEPTIC TANK SIZE:
RECOi•1MENDED MINIMUM LEACH FIELD SIZE:
RECOiMMENDED MINIMUM SQUARE FOOTAGE PER BEDROOM:
SITE HAS BEEN REVIEWED AND TESTED FOR PERCOLATION RATE.
Environmental Healtd Officer Date
COMMENTS: { i h C( oO up W(,�t4p_e- 1-/12 t T Raves 'f �Q Su2�Ac2
�`, _P Oq
y
Rev. 5/31/84
THEODORE K GUY ASSOCIATES PC
ARCHITECTS AND STRUCTURAL ENGINEERS
NO 1
n
October 28, 1988
Mr, Sid Fox
Eaqle County Community Development
Environmental Health Office
551 Broadway
Eagle, CO 89631
Dear Sid: ,-
The individual sewage disposal system being constructed under perms *887'is being installed by
Gil Lynd Plumbing and Mark Gressett the Excavator. Their addresses ak�as follows;
Gil Lynd Plumbing and Heating Mark Gressett
P.O. Box 391 501 Sopris Creek Rd.
Basalt, CO 8 162 1 Basalt, CO 81621
Please call if you need additional information.
Sincerely y urs,
Theodore K Guy
THEODORE K GUY ASSOCIATES PC
1kk
88138L1
351 STATE HIWAY 82 P.O. BOX 1 640 BASALT, COLORADO B1 621 (3033 927-31 67
1512 Grand Avenue, Suite 212
Glenwood Springs, Colorado 81601
(303) 945-1004
October 13, 1988
Mr. Sid Fox
Eagle County Environmental Health Department
P.O. Lox 850
Eagle, CO 81631
RE: Ted Guy ISDS
Dear Sid:
Please let this letter serve as a letter of transmittal for the Guy
ISDS in Mid Valley. I am transmitting the plan along with the letter
which has been authored just previous to this letter.
On October 13th, I inspected the Guy ISDS, at which time we determined
that the system, as designed (enclosed), can be a gravity system. As
you will depict from the letter enclosed, the major item which can be
eliminated from the orginal plan is the dosing tank and pump. Ted is
currently starting excavation for the field. I apologize for your not
having received a copy of the plan. However, as it works out, the
revisions and plan can be submitted together for your approval.
Another matter that I would like to transmit is the Eagle County's copy
of the Colorado Flood Proofing Manual. I appreciate very much the use
of the Flood Proofing manual; it helped me enormously. As I indicated
to you by phone, we are currently in a floodway revision with the
Federal Emergency Management Agency. This is the first revision for
Garfield County, and as I understand, Eagle County has never been
through this process. I will let you know how this revision turns out
(i.e., give you a report) so you may know what to expect in the future
if Eagle County has to initiate any floodway revisions themselves.
Again, thank you for the use of the manual.
If you have any questions regarding this letter, please do not hesitate
to call.
Sincerely,
SCHMUESER GORDON MEYER, INC.
JS:lc/8151
Enclosures
October 13, 1988
Mr. Ted Guy
Ted Guy Associates, AIA
351 Highway 82
Basalt, CO 81621
RE: Guy ISDS
Dear Ted:
1512 uranO Avenue, Suite 212
Glenwood Springs, Colorado 81601
(303) 945-1004
Per my site investigation on October 13, 1988, it appears that your
Wisconsin mound system as detailed for construction (SGM Job #B8151A),
dated August 10, 1988, can be gravity fed instead of a pumped system.
The following changes will need to be made to accomplish a gravity
system:
1) The distribution piping in the field must be increased in size to
a 4" diameter, perforated sewer pipe.
2 ) The line coming from the septic tank to the field must be a 4"
solid wall sewer pipe.
3) The distribution pipe in the field must be interconnected (i.e.,
the laterals must all be connected with header pipe at the front
of the field and at the end of the field) .
4) The dosing tank may be eliminated from the plan. However, the
1000 gallon concrete septic tank must still be installed. The
bed construction, consisting of two feet of sand, must remain
along with the 6 inches of gravel below the bottom of the distri-
bution piping. The gravel must cover the top of the pipe and
then be topped with Mirafi® 140-N filter fabric. Finally, the
six to twelve inches of topsoil must be located on top of the
Mirafi®.
I will be submitting a copy of this letter to Sid Fbx with Eagle
County. I hope this letter serves its intended purpose. Please do not
hesitate call if you have any questions.
Sincerely,
SCHMUESER GORDON MEYER, INC.
Simonson
JS:lc/8151
cc: Mr. Sid Fbx
October 21, 1988
Mr. Sid Fox
Environmental Health Department
Eagle County
P.O. Box 179
Eagle, CO 81631
RE: Guy ISDS — Mid Valley
Dear Sid:
1512 Grand Avenue, Suite 212
Glenwood Springs, Colorado 81601
(303) 945-1004
,a
IECEI E
OCT 2 5 88
Dept of coiinn. �'ev.
Elope W 81631
Per my site investigation on October 21, 1988, I was able to observe
the progress of the construction of the Guy ISDS. As of this date, the
Contractor had completed all of the bed construction with the exception
of the topsoil. All of the pipe was installed from the house to the
septic tank, and from the septic tank to the field. Essentially, re-
maining work for the Contractor is backfill.
My observations indicated that the bed was constructed per our plans
and as revisions. If you have any questions, please do not hesitate to
call.
Sincerely,
SCHMUESER GORDON MEYER, INC.
f Simonson
JS:lc/8151
cc: Ted Guy
THEDo0F1E K [3UY ASSOCIA"S PC
ApemiTECT8 AND $TRVCTURAL ENOINKERD
February 11. 1998
Ray Merry Fax 970 328-7185
Eagle County Community Development
Eagle, Colorado
Re: Heron House, 0743 Willits Lane, Basalt, Colorado
Dear Ray;
When we bought this property in 1986 it had two trailers, each served by its own individual septic
system.
System one served a two bedroom one bath trailer it is now serving the old homestead residence
that was restored in 1992. It has a concrete two compartment tank located in the apple orchard
north of the homestead residence.
System two served a five bedroom two bath double wide trailer that was the primary residence at
the time- This system has a 1$00 gallon concrete two compartment tank located on the east side
of the barn and the leach field is north of the barn. This is the system that will serve the new
employee structure we have named Heron House.
1n 19BB we applied for a third and new septic system for our primary residence. I believe that
was permit 88-7. The system was designed by Schmueser Gordon Meyers. It was built in
accordance with their design drawings and consists of a two compartment concrete tank next to
the house with gravity flow to a leach field that contains imported sand in a fabric lined pit.
The water table is relatively deep because we are so high above the river. We have a 5'-4" deep
crawl space in our primary residence that is above the ground water level.
Please call if you have any other questions.
Since ,ely Yours;
i
T4 uy, AIA,PE, President
THEODORE K GUY ASSOCIATES PC
TKG/tkg
98101 L1
23200 ?WO RIVERS ROAD P.O. Box 1640 BASALT. COLOFAOO g1E21 (970) 927.31G7
CA ii
Z Fn M
Ln o Z H W M q
��
> C
K 0
to►K N O+ iv
H Z
Sv (D
rt F- (D H rt rt
A.
M 1-3
�
E �
a
K
o cct
t-b Prt- CD tO
•
Ki
a% Lo
:4 ti (D :3* iv rtcv
Cl
on
cD -
�•
t1
rr
n � rt. "o w o
t-4 :r'
H- a ::r
n n CD (D
o
t
Z rn
co
'
t r
1 t-4
�0
c n
0 z CD 0o O
tl1
J
v
O (D Fib
fi �C (n i, O
H
1-4 o
O
O"Fi
ni "r- ti
c
Enw
xtr
CD rt
`�acCDtr
CDD (nn
N K
N- (D H- rt-
0 �-
a rt
rr w ti rn A) o •
.
ann
FAO lF-n
rt K A)
(D rt Qr N W cn
M
O' (D rt,
ro � &
ncv
M C6 ►`.o
w�c
w =°irn w
O
oa
.
CD
J (D H
(D G K (D O'
0r (D 0)
(i 15 (n Fj- rn W
sz Z
O tr (D O c t ro•
• a
0(DQjw
s
Q O
LC N rt (D LZ+
O �:%
lt�. (n
n c
x% rt rt- �r z r
Qj (D
O t.0 F-n rn
w
ri o p, rt ro H
3
O, w iv rt, :3' P)
rt,
(D rt :r Fi
LC O
Fi n (D (D ro rf (n
- cD (D
-jro
En 0 O (') :R:O 0
CD
O H, O rt, rt
rt
O K r Fl-
F-J (D
F-n (z rt Z H O
N
rn (D -'r rt- A) Fi
m
f✓- Rl (D LC 0 A)
00 C4
O O Q
•
(D H- (D W O rt o
A�
• �:s X O rl
F_j
to o £L H- v H
:d A►
O rl O O
LQ
0 (A
P' Fes'- : m
(D Fes•
O O & (D cn
"O (D
a) E O Q ::;'
rt Fj
cn rt FJ-
H•
O P-to
O 0)
w Ft Al O
rt [n w
o
rt
ro �
a Di
st rt
cD
J
iL-UL+LrcL. n. kau T F-V'.).71.71,
THEDOCRE K GUY AB8®GIA'rE® PG
AiACHITECTR AND STRUCTURAL ENOIN®ERB
rRut U L
February 11. 1998
Ray Merry
Eagle County Community Development
Eagle, Colorado
Re. Heron douse, 0743 Willits Lane, Basalt, Colorado
Dear Ray;
Fax 970 328-7185
When we bought this property in 1986 it had two trailers, each served by its own individual septic
system.
System one served a two bedroom one bath trailer It is now serving the old homestead residence
that was restored in 1992. It has a concrete two compartment tank located in the apple orchard
north of the homestead residence.
System two served a five bedroom two bath double wide trailer that was the primary residence at
the time- This system has a 1 $00 gallon concrete two compartment tank located on the east side
of the barn and the leach field is north of the barn. This is the system that will serve the new
employee structure we have named Heron House.
1n 1908 we applied for a third and new septic system for our primary residence. I believe that
was; permit 88-7_ The system was designed by Schmueser Gordon Meyers It was built in
accordance with their design drawings. and consists of a two compartment concrete.tank next to
the house. with gravity. flow to a leach -field .that contains imported sand in a fabric lined pit.
The water table is relatively deep because we are so high above the river. We have a 5'-4" deep
crawl space in our primary residence that is above the ground water level.
Please call if you have any other questions.
Since ,ely Yours;
s
T uy, AIA,PE, President
THEODORE K GUY ASSOCIATES PC
TKG/tkg
98101 L1
23200 TWO RIVERS ROAD P.Q. 8OX 1840 BASALT. COLORADO 131621 (970) 927.3167
�887 Guy 0743 Willits Lane
JOB NAME _ JOB NO. r�
JOB LOCATION
BILL TO
DATE STARTED
DATE COMPLETED
DATE BILLED
JOB COST SUMMARY
TOTAL SELLING PRICE
TOTAL MATERIAL
TOTAL LABOR
INSURANCE
SALES TAX
MISC. COSTS
TOTAL JOB COST
GROSS PROFIT
LESS OVERHEAD COSTS
% OF SELLING PRICE
NET PROFIT
JOB FOLDER Product 278 j�® NEW ENGLAND BUSINESS SERVICE, INC., GROTON, MA 01471 Printed ig U.S.A.
JOB FOLDER
t
e
i
I
I�
0
tr
COPYRIGHT - - -
THE000RE K GUY
ASSOCIATES PC
I
I
_1
vi
x
-�-� i . � r --- -Fnit4T
- --- ----- - - by a -E - - - - -
✓r IG ti TQ 0, E
Ve.)p,�.
�i•—W _ r~ _f`---_ �: — _ _ 4 — --��LV
_ /di � _�� � � Grt�%ttt,iCt 1�=!-�c:.i•� FIELrJ i i ^�1- �.e.�-- --
—71(�__---'A "Cyr
_ r� 1
worL
-- ,
_ X
c%4
t4 c-roQic EIve�2
IF
V IC I �� I -FY MZ�P
s
a -&
Tj?�C�F't-t�H1G M�'�s�Plrv�T �ATt�c� 1 JUG`; ia�c�j
-
f
f
t DRAWN — E
CHECKED .--.--
ISSUED
I _
t
r