HomeMy WebLinkAboutTrappers Cabin - 210514301002INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT Eagle County Department of Environmental Health PERMIT N® 0805 P.O. Box 850 - 550 Broadway Eagle, ColorG do 81631 Telephone: 328-7311 or 949-5257 or 927-3823 YELLOW COPY OF PERMIT MUST PLEASE CALL FOR FINAL INSPECTION BEFORE BE POSTED AT INSTALLATION SITE COVERING ANY PORTION OF INSTALLED SYSTEM Owner: Vail Associates Telephone: 949-5750 Address: P.O. Box 7 Vail CO 81658 System Location: Beaver Creek Mountain - Western Hillside 2.75 A. Licensed Installer: Ewing Trucking & Construction 949-7502 License Number: Conditional installation approval is hereby granted for the following: Minimum requirements: /5 Gallon Septic Tank or Aerated Treatment unit Absorption area of dispersal area computed as follows: Percolation rate:_ Inch in 8, q3 Minutes j0- Absorption area per bedroom Sq. Ft. .157 Number of Bedrooms X Sq. Ft. minimum requirement per bedroom - equals -Total Sq. Ft. minimum requirement Specialp Requirements: <�2 'El51• CS-Z7,;+V)-) A9 �j� , vjAyjAiL) '�n�� Date: 9-11-87 Environmental Health Officer: Sid Fox S —e-n C CONDITIONS: I. All installations must comply with all requirements of the Eagle County Individual Sewage Disposal System Regulations, adopted pursuant to authority granted in 25-10-104, C.R.S. 1973, as amended. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Connection to or use with any dwelling or structure not approved by the zoning and building departments shall automatically be a violation of a requirement of the permit andcause for both legal action and revocation of the permit. 3. Section III, 3.21 requires any person who constructs, alters or installs an Individual Sewage Disposal System to be licensed according to the regulations. FINAL APPROVAL OF SYSTEM: No system shall be deemed to be in compliance with the Eagle County Individual Sewage Disposal System Regulations until the system is approved prior to covering any portion of the system. INSTALLED ABSORPTIO OR DISPERSAL AREA: SQ. FT. INSTALLED SEPTIC TAI� SQd GALLONS; g�, a DEGREES; 3� / �FEET DESIGN ENGINEER OF SYSTEM: INSTALLER OF SYSTEM: SEPTIC TANK CLEANOUT TO WITHIN 12"OF FINAL GRADE OR AERATED ACCESS PORTS ABOVE GRADE: PROPER MATERIALS AND ASSEMBLY: COMPLIANCE WITH PERMIT REQUIREMENTS: COMPLIANCE WITH COUNTY / STATE REGULATION REQUIREMENTS: COMMENTS: r, PHONE: YES NO YES: NO YES O YES NO (Any item checked NO requires correction before final approval of system is made. Arrange a re -inspection when work is completed.) I Z _Z--t 7 DATE (Fiv@el Approval) ENVIRONMENTAL HEALTH OFFICER: WL DATE (Re-Inspection)7--/'�-�L, ENVIRONMENTAL HEALTH OFFICER: RETAIN WITH RECEIPT RECORDS PERMIT e of Applicant: Colo. Custom Log Const. Name of Owner: Vail Associates int Paid: $150.00 Receipt Number:-3874 Date: 9-11-87Cashier: Christie Baldwin Check ll 2542 White and Pink Copies - Environmental Health Department Yellow Copy - Applicant / Owner AP? T_C:;t"`, FOR - '`*• T".;.aL SF--;AGOTSP(_�S'tL :S' pr.T•.,T_ E::;'IRO:: fE::TAL i-c-ALTH OFF :CE - EAGLE CC.U:'T`.' . i P.O. uo:: 350 Eagle, Colorado 81631 ;:o. PER`fIT A2PLICATTON FEE: S150.00 328-7311 PFRCOL;TIO`: TEST F=7$125.00 NAME OF OId1ER: Vai_1 Associates. Inc. ADDRESS: P _ n . Box 79 Vail, Colorado 81658 PIIO::E: 949-5750 NAME OF APPLICANT (if different from owner): Colorado Custom Log Construction, Inc. ADDRESS: 141L Main / P.O. Box 48 Lyons, Colorado 80540 PHO`:E: 442-7979 DESIGN ENGINEER OF SYSTDI (if applicable): Inter Mountain Engineering ADDRESS: Mr-+ra1f. Avon, Colorado PHO::E: 949-5072 PEnavtr i�L.L v:,Jiu: IOC; INSIALL:%TION OF SYSTE`I: Ewing Trucking & Construction Co. (Bill Ewing ` Licensed Installer (see attached list): YES X _ NO ADDRESS: _u+ A Box 198 159 Gold Road, Black -Hawk, CO 80422 PFO.:E: 949-7502 PER`1IT APPLICATION IS FOR: ( X) New Installation ( ) Alteration ( ) Repair LOCATION OF PROPOSED INDIVIDUAL SEJAGE DISPOSAL SYSTz.I: Street/Rural Address: Beaver Creek Mountain - Western Hillside Lot Size: 2.75 A. Legal Description: Re: Attached BUILDING OR SERVICE TYPE (check applicable cate^_orv)• ( ) Residential - Single Family ( ) Residential - Quadolex ( ) Residential - Duplex ( X) Co.,-.ercial (state usage) ( ) Residential - Tr_olex vern' ht b' NLnfBER OF PERSONS: I n WASTE TYPES (check applicable cate^ories): (X) Co=ercial or Institutional ( ) Non -Domestic Wastes ( ) Garbage Disposal ( ) Automatic Washer ( ) Other E OF INDIVIDUAL =.-AGE DISPOSAL SYST"r_-i PROPOSED: (X) Septic Tank ( ) Composting Toilet ( ) Vault Privy ( ) Greywater ( ) Pit Privy ( ) Aeration Plant ( ) Other o lg ca in N17•IBER OF BEDROOMS: 4 ( X) Dwelling ( ) Transient Use ( X) Dishwasher ( ) Spa Tub ( ) Incineration Toilet ( ) Chemical Toilet ( ) Recycling, Potable Use ( ) Recycling, Other Use WILL EFFLUENT BE DISCHARGED DIRECTLY INTO T.'ATERS OF THE STATE: YES ( ) NO ( X) IS SYSTEM DESIGNED FOR LESS T'dAN 2,000 GALLON:S PER DAY: YES (X ) NO ( ) WASTEi:?�,TER FLOW REDUCTION PLAN: YES ( ) NO ( X,) (I S Yes, see attached tcas te:w Lte•`. S.ec•cv .'cedctction methods) NOTE: The EnvZ'Lo vnejLta("'_ Heael 't OSS.i.cet may seduce the .tequit1-d ab.so-LptZojt atea upon app,tovae o5 an ade0ua.t . =ti t zxc tet SZCtU teduc.tCon pZaji. SOURCE AND TYPE OF WATER SUPPLY: ( X) well o ( ) Sprino ( ) Creel:/Stream Give depth of all wells within 200 feet of system: 300' If supplied by community water, give name of supplier: N/A SIGNATUREDATE -- - - - - -- - -------------�0------- INFORMATION BELOW TO BE FILL OUT BY ENVIRON'IEMTAL HEALTH OFFICER: Sir �N�, SPee- .S GROUND CONDITIONS: Peteent G,'cound S.Zope r Depth .to Beci'coeh ( pet 8' P7o S'Zee Hole) Depth .to GtounCrLvc,te'L Tab.ee SOIL PERCOLATION TEST RESULTS: A. ;uLtc.s per..utct .cn Ho.Z-e nl flinu,tes pet .inch .to Ho.ee # 2 f+u Ycu,t.e s pe'-'. .(.'lck to Hone #3 FINAL DISPOSAL RV: ( ) Abso.-cptio;l Trench, Bed of Pit ( ) Above GAcu►td D.i.spena.e ( ) Undetg.totuid Dispe-uae ( ) Evapo.tta s piAc tiaj2 ( ) Sajtd F.i_Ltet ( ) Was.t ,3c•a.tc t Pond Amuujct Paid: � � � . Receipt Ncunbe.`c 8% J DcLt2: NOTE: Site Plan must be attached to'application. (Env. Health Department - Rev. 4-07-33) Location: Beaver Creek Planned Unit Development Legal: That part of the E 1/2 NW 1/4, Section 23, Township 5 South, Range 82 West of the Sixth Principal Meridian, Eagle County, Colorado described as follows: Beginning at a point whence an existing brass cap monument marking the NW 1/16 corner of said Section 23 bears N730W 100 feet; thence N33'E 200 feet; thence S57'E 600 feet; thence S33'W 200 feet; thence N57°W 600 feet to the point of beginning, containing 2.75 acres, more or less. e -K =neeringu& ountain j\j ED PERCOLATION TEST RESULTS��Cf AND SEPTIC RECOMMENDATIONS SAP 1 1 198� FOR "TRAPPER'S CABIN" E��IjN�Y AT BEAVER CREEK E , p�NG DEPj' EAGLE COUNTY, COLORADO PREPARED FOR: EWING TRUCKING AND CONSTRUCTION COMPANY PROJECT NUMBER V-7148G AUGUST 1987 Box No. 978 1420 Vance Street Avon, Colorado 81 620 Lakewood, Colorado 80215 949-5072 Denver 893-1 531 Phone: 232-01 58 C SCOPE This report presents the results of percolation tests and provides septic system recommendations for the proposed "Trapper's Cabin" at Beaver Creek, Eagle County, Colorado. SITE INVESTIGATION The site was investigated on August 12, 1987, and three percolation test holes were dug to a minimum depth of 30 inches. Holes were presoaked and percolation tests performed on August 13, 1987. Results of these tests are included in this report; see PERCOLATION TEST RESULTS. Also, a test pit was excavated to a depth of 7.5 feet on August 14, 1987, with a conventional backhoe. An investigation of the test pit was performed on August 17, 1987. A summary of the test pit log is also a part of this report; see Figure No. 1. Locations of the percolation test holes and the test pit are shown on Drawing No. 1. SITE LOCATION AND DESCRIPTION The site is located in a part of the East one-half of the Northwest one -quarter, Section 23, Township 5 South, Range 82 West of the Sixth Principal Meridian, Eagle County, Colorado, and is more particularly described on Drawing No. 2 of this report. 2 SITE LOCATION AND DESCRIPTION - continued The site is generally sloping to the southeast, and was covered with mature aspen trees. The cabin site has been cleared of trees, and a view corridor approximately 30 feet wide has been clear-cut to the southeast. SUBSURFACE AND GROUNDWATER CONDITIONS Subsurface conditions in the proposed leach field area are uniform, and consist of sand and gravel over weathered bedrock. Refer to Figure No. 1 for additional information. PERCOLATION TEST RESULTS A total of three percolation tests were performed on the site as specified by the Eagle County Individual Sewage Disposal System Regulations. Results were as follows: Test Hole Min/1" Drop Date of Test Ambient Air Temp. 1 9.2 8/13/87 65 2 7.5 8/13/87 65 3 8/6 8/13/87 65 Average time for 1 inch drop = 8.43 minutes DESIGN CRITERIA A log cabin has been proposed for this site for year-round use. The cabin will have a total of five (5) bedrooms, and 3 DESIGN CRITERIA - continued will not be equipped with a garbage disposer or automatic washing machine. Thus design criteria for calculations are: 2 persons/bedroom 75 gallons/person/day - average flow Maximum flow: 150% of average flow CALCULATIONS A = QY where A = minimum absorption area (sq.ft.) Q = maximum quantity of sewage flow (gal/day) T = percolation rate (min/inch) Q= 5 x 2 x 75 x 1.5 = 1,125 gal/day A = 11258.43 r= 653.3 square feet From Table 5 (Section 8.1 of the Eagle County Regulations), minimum absorption area for seepage beds is 215 square feet/ bedroom; therefore, 5 x 215 = 1,075 square feet of seepage bed required. From Table 4 (Section 7.1.a of the Eagle County Regulations), a 1500 gallon septic tank is required. SEPTIC SYSTEM RECOMMENDATIONS Based on the preceding calculations, it is recommended to install a 1500 gallon compartmented septic tank followed by a minimum 1075 square foot seepage bed. The seepage bed should lie a minimum of 10 feet from all property lines, 30 feet from the proposed cabin, and 100 feet from the existing well. 4 SEPTIC SYSTEM RECOMMENDATIONS - continued An inspection of the system should be made by a representative of the Eagle County Environmental Health Department prior to backfilling. The installation and material specifications must comply with the Eagle County Individual Sewage Disposal System Regulations. As an alternate to the standard 1,075 square foot seepage bed, 360 lineal feet of 10-inch diameter "gravel -less" leach bed tubing (as manufactured by American Drainage Systems, Inc.) could be embedded in the native soils of the site. Due to the remoteness of the site, this alternate would probably be cost effective. It is also recommended as options to either of the pre- ceding alternates to add a dosing chamber to the septic tank and an alternating valve to the seepage bed. The dosing chamber would allow for periodic high rate discharge to fill the drainage field instead of a slow trickle into the field. This would prolong the life of the drainage field. The alternating valve can also prolong the effective life of the drainage field by allowing an alternating flow of effluent to two separate halves of the drainage field. This allows the unused portion of the drainage field to rest and regenerate its opti- mum characteristics. 5 CONCLUSIONS This report has been prepared for the exclusive use of Ewing Trucking and Construction Company, for the specific application to the proposed "Trapper's Cabin" site at Beaver Creek, Eagle County, Colorado. The findings and recommendations of this report have been obtained in accordance with accepted professional engineering practices. There is no other warranty, either expressed or implied. If we can be of further assistance, please do not hesitate to call. Sincerely, INTER -MOUNTAIN ENGINEERING, LTD. Michael Ley Field Engineer Reviewed and approved by: V ✓l,���� �e��-c/ o� .••••••.. ,;.; -G. M4lc;Project Thomas Allen, P . E. Engineer QJ 22793 1 -•�.•QD . 4 i i �•' That part of the E 1/2 NW 1/4, Section o 23, Township S South, Range 82 West of j the Sixth Principal Meridian, Eagle County, Colorado described as follows: Beginning at a point whence an exist- 401 l ing brass cap sonument marking the NW 1/16 corner of said Section 23 bears N730W 100 feet; thence N339E 200 feet; • ���'r: ; t thence S57'E 600 feet; thence S33'W 200 feet; thence N57•W 600 feet to the .x1 point of beginning, containing 2.75 acres, more or less. i / , •f711 .,•M, / / X, i a mow• ' / � r �r ) 0 1` - " -33?W 200' _ POINT OF BEGINNING NW 1/16 CORNER SECTION 23 N730W 100' N 330 E 200' PROJECT No.: V - 7148 G DRAWING NO., 2 �Q 3,5 P DEPTH 0 v� IN FEET 0 TOPSOIL 5 110 115 PI T NO. 1 DESCRIPTION OF MATERIAL SAND & GRAVEL :Q- O'0 00. o' b O.cd �o o.°. .o• '•�prj o. WEATHERED BEDROCK Bottom of Test Pit 7.5' lencountered. No groundwater SUMMARY OF TEST PITS PROPOSED "TRAPPER'S CABIN" AT BEAVER CREEK EAGLE COUNTY, COLORADO FOR VAIL ASSOCIATES REMARKS PROJECT NO.: V_7148G FIGURE NO.: 1 December 14, 1987 Dick Funk P.O. Box 7 Vail, Colorado 81658 Dear, Mr. Funk An inspection of the individual sewage disposal system for the "Trappers Cabin" on December 2, 1987 revealed that only half of the required Sb2 drainage pipe was installed. Ewing Trucking and Construction Company indicated that would like to install the rest of the drain field next spring. The system is equipped with a diversion valve that should be changed once each year, in the summer months. Since the diversion valve would not need to be changed until next summer, it will be appropriate to install the remaining Sb2 drainage pipe at that time. The system should function as installed this winter, however the remaining Sb2 pipe and connection to the other side of the diversion valve should be completed by July 1, 1988. A final inspection and approval will be granted at that time, if the system is installed according to the Inter -Mountain Engineering specifications. Please note the Engineer specified 360' of 10" Sb2 pipe, only two 90' lengths of pipe were installed If you have any questions regarding this letter please contact Erik Edeen of the Eagle County Environmental Health Office. Sincerely, Erik W. Edeen Eagle County Environmental Health Officer copy: Ewing Trucking Co. Intermountain Engineeering Nola S. Dyal December 14, 1987 Dick Funk P.O. Box 7 Vail, Colorado 81658 Dear, Mr. Funk An inspection of the individual sewage disposal system for the "Trappers Cabin" on December 21 1987 revealed that only half of the required Sb2 drainage pipe was installed. Ewing Trucking and Construction Company indicated that would like to install the rest of the drain field next spring. The system is equipped with a diversion valve that should be changed once each year, in the summer months. Since the diversion valve would not need to be changed until next summer, it will be appropriate to install the remaining Sb2 drainage pipe at that time. The system should function as installed this winter, however the remaining Sb2 pipe and connection to the other side of the diversion valve should be completed by July 1, 1988. A final inspection and approval will be granted at that time, if the system is installed according to the Inter -Mountain Engineering specifications. Please note the Engineer specified 360' of 10" Sb2 pipe, only two 90' lengths of pipe were installed If you have any questions regarding this letter please contact Erik Edeen of the Eagle County Environmental Health Office. Sincerely, Erik W. Edeen Eagle County Environmental Health Officer copy: Ewing Trucking Co. Intermountain Engineeering Nola S. Dyal Dick Vail P.O. Vail, Funk Associates, Box 7 EAGLE COUNTY Inc. Colorado 81658 551 Broadway Eagle, Colorado 81631 (303) 328-7311 December 15, 1987 Re: Trappers Cabin sewage system Dear Mr. Funk, An inspection of the individual sewage disposal system for the "Trappers Cabin" on December 2, 1987 revealed that only half of the required Sb2 drainage pipe was installed. Ewing Trucking and Construction Company indicated that they would like to install the rest of the drain field next spring. The system is equipped with a diversion valve that should be changed once each year, in the summer months. Since the diversion valve would not need to be changed until next summer, it will be appropriate to install the remaining Sb2 drainage pipe at that time. The system should function as installed this winter, however the remaining Sb2 pipe and connection to the other side of the diversion valve should be completed by July 1, 1988. A final inspection and approval will be granted at that .time, if the system is installed according to the Inter -Mountain Engineering specifications. Board of County Commissioners Assessor Clerk and Recorder Sheriff Treasurer P.O. Box 850 P.O. Box 449 P.O. Box 537 P.O. Box 359 P.O. Box 479 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Jim Funk Vail Associates, Inc. December 15, 1987 Page Two Please note; the engineer specified 360' of 10" Sb2 pipe, only two 90, lengths of pipe were installed. If you have any questions regarding this letter, please contact Erik Edeen of the Eagle County Environmental Health Office. Sincerely, Erik W. Edeen Eagle County Environmental Health Officer copy: Ewing Trucking Co. Intermountain Engineeering Nola S. Dyal .Files JOB NAME ) C- �400 W-1 La4 � JOB NO. J� JOB LOCATION BILL TO DATE STARTED DATE COMPLETED DATE BILLED JOB COST SUMMARY TOTAL SELLING PRICE TOTAL MATERIAL PERMIT # 805 OWNER: Vail Associates LOCATION: Beaver Creek Mountain - Western Hillside INSTALLER: Ewing Trucking & Cosntruction SIZE OF TANK: 1000 + 500 Gallons DWELLING: 4 BR Commercial PERC RATE: ABSORPTION AREA: FINALIZED: 7-13-88 BY: Erik Edeen TOTAL LABOR INSURANCE SALES TAX MISC. COSTS TOTAL JOB COST GROSS PROFIT LESS OVERHEAD COSTS % OF SELLING PRICE NET PROFIT OLDER Printed in U.S.A. � t t I i a ;y .r 1 'Y P. 9 � � o ' J+ ZY