HomeMy WebLinkAbout398 Mountain View - 239122201002 - 0666IS (2)EAGLEiCOUN1Y DEPARTMENT OF ENVIRONMENTAL HEALTH
PLEASE CALL FOR FINAL P. 0. Box 850 - 550 Broadway PERMIT MUST BE POSTED
INSPECTION BEFORE COVERING Eagle, Colorado 81631 AT INSTALLATION SITE
ANY PORTION-* OF INSTALLED SYSTEM
328-7311 or 949-5257 or 927-3823
OWNER: Randy Rahne
SYSTEM LOCATION: Lot #8 -
LICENSED INSTALLER: Eldorado
PERMIT NO. N° 666
ADDRESS:
Aspen Mountain View
- Design Engineer
P.O. Box 3821 - Aspen, CO
(approx. 2 acres)
LICENSE NUMBER:
"CONDITIONAL INSTALLATION APPROVAL is hereby granted for the following:
MINIMUM REQUIREMENTS: 1,000 gallon septic tank or aerated treatment unit.
Absorption area or dispersal area computed as follows:
one
PERCOLATION RATE: xxAxxx --inch in ten minutes.
Absorption Area per Bedroom sq. ft. (per design engineer)
No. of Bedrooms 3 x sq. ft. minimum requirement per bedroom
= total sq. ft. minimum requirement.
SPECIAL REQUIREMENTS: square footage requirements as per design engineer.
DATE: 6/19/84
"CONDITIONS:
INSPECTOR:
1. All installation must comply with all requirements of the County Individual Sewage
Disposal System Regulations, adopted pursuant to authority granted in 25-10-104,
C.R.S. 1973, as amended.
2. This permit is valid only for connection to structures which have fully complied
with County zoning and building requirements. Connection to or use with any
dwelling or structure not approved by the building and zoning departments shall
automatically be a violation of a requirement of the permit and cause for both
legal action and revocation of the permit.
3. Section III, 3.21 requires any person who constructs, alters, or installs an
individual sewage disposal system to be licensed according to the Regulations.
FINAL APPROVAL OF SYSTEM: No system shall be deemed to be in compliance with the Eagle
County Individual Sewage Disposal System Regulations until the installed system is
approved prior to covering any part. n
Installed Absorption or Dispersal Area: � � G/ t. ��� �P f
�` s
Installed Septic Tank: (000 gallons. Degrees: ,� 7® Feet: /
Design Engineer of System: J?iCK /6&z-&6Iq
Installer of System: Phone:
Septic tank cleanout to within 12" of final grade or
aerated access ports above grade? Yes �_No
Proper materials and assembly? Yes No
Compliance with permit requirements? Yes No
Compliance with County/State regulations requirements? Yes No
COMMENTS : /A)STGzL)c iT,9 2� %057atL �G qQ A/45 r//1 6-t37-
(Any item checked "No" requires correction before final approval of system is made.
Arrange a re -inspection when work is completed.)
DATE: 1 I - P/�/ INSPECTOR: 3 0
RE -INSPECTION DATE INSPECTOR:
RETAIN WITH RECEIPT RECORDS -
PERMIT N0. Na 666
CHARGES Name of Applicant: Randy Rahne
Percolation Test = $50.00
Permit Fee (includes final inspection) _
ALL CHECKS OR MONEY ORDERS ARE TO BE
MADE PAYABLE TO: EAGLE COUNTY
Name of. Owner: Randy Rahne
Amount Paid: $200.00 (6/13/84)
Receipt Number: C-0163
Cashier: Lorraine Funke
White and Pink Copies - Environmental Health Department Green Copy - Applicant/Owner
'APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
PERMIT APPLICATION FEE:
ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY
P.O. Box 850.
Eagle, Colorado 81631 No. r
150.00 PERCOLATION TEST FEE: $50.00
NAME OF OWNER: /' -L 4
ADDRESS: /O • S C� ,, ��.t ,
PHONE: 9 G 3 -'Z2 ro 3
NAME OF APPLICANT (if different from owner):
ADDRESS: PHONE:
DESIGN ENGINEER OF SYSTEM (if applicable): %�.�- � �_� .� J'__c
ADDRESS: PHONE:
PERSON RESPONSIBi�E FOR INSTALLATION OF_ SYSTEM: 2C el—.-
Licensed Installer (see attached list): YES c/ NO
ADDRESS: PHONE:
PERMIT APPLICATION IS FOR: (tJj New Installation -( ) Alteration ( ) Repair
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Street/Rural Address: �__AL
Lot Size: e ,
Legal Description:gp�_
BUILDING_ OR SERVICE TYPE (check applicable category):
(�✓j Residential - Single Family
( ) Residential - Duplex
( ) Residential - Triplex
NUMBER OF PERSONS: 3
WASTE TYPES (check applicable categories):
( ) Commercial or Institutional
( ) Non -Domestic Wastes
( Garbage Disposal
Automatic Washer
( ) Other
TYPE
OF
INDIVIDUAL SEWAGE
DISPOSAL SYSTEM PROPOSED:
(�
Septic Tank
( ) Composting Toilet
(
)
Vault Pricy
( ) Greywater
(
)
Pit Privy
( ) Aeration Plant
(
)
Other
( ) Residential - Quadplex
( ) Commercial (state usage)
NUMBER OF BEDROOMS:
( ) Dwelling
( ) Transient Use
(1-) Dishwasher
( ) Spa Tub
( ) Incineration Toilet
( ) Chemical Toilet
( ) Recycling, Potable Use
( ) Recycling, Other Use
WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE: YES ( ) NO (�-j
IS SYSTEM DESIGNED FOR LESS THAN 2,000 GALLONS PER DAY: YES NO ( )
WASTEWATER FLOW REDUCTION PLAN: YES ( ) NO ( )
(16 yeas, See attached waatecuateA Wtv neduc ion methods )
NOTE: The Envitt.onmentae Health 016.icen may Reduce the Aequi %ed absonpti.on a&ea upon
app&0vat 06 an adequate wastecvate& Stow &eduction plan.
SOURCE AND TYPE OF WATER SUPPLY: ( ) Well ( ) Spring ( ) Creek/Stream
Give depth of all wells within 200 feet of system:
If supplied y co unity water, gi e name of supplier:��,
- -SIGNATURE- - - - - -`- - - - - - - - - - - - - - - - - - - - - DATE- - -/ X-
INFORMATION BELOW TO BE FILLED OUT By ENVIRONMENTAL HEALTH OFFICER.
GROUND CONDITIONS: Pe/LCent Ground Stope
Depth to Bedtcock (pen. 8' Pro4ite Hote)
Depth to GnoundWateA Tabte
SOIL PERCOLATION TEST RESULTS:. Minutes pets inch tin Hote #1
Mi.nuta peA inch to Hote #2
Uinute�s pen .inch to Hote # 3
FINAL DISPOSAL By:
( ) Absonption Trench, Bed oA Pit
( ) Above Ground DZspehsae
( ) Underground Di6pe&6at
( ) OtheA
( i Evapotnaws pitrati.on
( ) Sand F.c ?,teA
( ) Wa�stewateA Pond
Amount Paid: Receipt Numb - Dade: s
NOTE: Site Plan must be attached to application.
(Env. Health Department - Rev. 4-07-83)
v
Q
PERCOLATION TEST
ENVIRONMENTAL HEALTH DEPARTMENT
Eagle County
FEE: $50.00 ISDS APPLICATION NO.
OWNER:
LEGAL DESCRIPTION:
RURAL ADDRESS: /
TYPE OF DWELLING: c� �%� �( NUMBER OF BEDROOMS:
i
DATE OF PERCOLATION TEST: — TYPE OF SOIL:G�
TEST HOLES PRE-SOAKED: YES NO
TIME
WATER DEPTH
INCHES OF FALL
RATE
1
2
3
1
! 2
3
1
2
3
1
2
3
Sri
SiL3Z
ct-,e
/r
37
i
PERCOLATION RATE:
RECOMMENDED MINIMUM SEPTIC TANK SIZE:
RECOMMENDED MINIMUM LEACH FIELD SIZE:��ii��—�'Sr��
RECOMMENDED MINIMUM SQUARE FOOTAGE PER BEDROOM:
SITE HAS BEEN REVIEWED AND TESTED FOR PERCOLATION RATE.
�=(O, 7 6— IL->,
Environmental Health Officer Date
COMMENTS:
Rev. 5/31/84 �� i
UINW-7 t-U T_L4,
or 3 9 C- Mon . O'eto
JOB LOCATION
BILL, TO
DATE STARTED DATE COMPLETED
1/yL�
PERMIT No. 666
OWNER: Randy Rahne
P.O. Box 3821 - Aspen, CO
LOCATION: Lot 8 - Aspen Mountain View (approx. 2 acres)
INSTALLER: Eldorado - Design Engineer (Rick Kinshilla)
SIZE OF TANK: 1,000 gallons - 270 degrees; 15 feet
DWELLING: Single family - 3 bedroom
Absorbation area: 180 lineal feet -extra cravel
ATE BILLED
JOB NoQ
0 C/(J,v v leuel
14,0
instructed to install sch.40 plastic or cast iron at the
inlet and outlet
Finalized: 9/19/84 By: Sid Fox
LDER
.
LOT: 8
All�T��S
Add 60% for Washer and Disposal A = 426 x 1.6
= 683 ft: 2
Length of 3' Wide Trench = 683 E
3 -
t 228 L. F. _
f
Adjustment for Deep Gravel 3 + 2
1 3 + 1 + 2
= 5 = .83 I I I
Install 189 feet of 3 ft. wide trench w/12 of rock below pipe.
f
General Notes
1. All materials, installation practices, and setback requirements
shall comply with Eagle County Individual Sewage Disposal
I Regulations. F.
4 o t c< < -
-_ a
= a -
• NO.
2. The bottom of the absorption field shall -be constructed level.
3: The Eagle County Enviromental Health Department shall be notified
when construction commences so ttat inspections can be performed.
..
4. The location of existing utilities must be verified by contractor
r
prior to commencing work.
5. The location of the leachfield tray be adjusted in the field to
=
!
r
better fit the site provided all setbacks are meta
r
k
SCHMUESER & ASSOCIATES
ff
1
ENGINEERS & CONSTRUCTORS
1512 GRAND AVENUE, SUITE. 210
GLENWOOD SPRINGS, COLORADO 81601
=
13031 945 - 5468
REVISIONS
ENGR. RECORD
DRAWING STATUS
SEWAGE DISPOSAL ;SYSTEM
DESCRIPTION
DATE
BY
CHKD.
MNGR
MECH. CHK.
ISSUED
DATE
_ .4 RE RA, AND RANDY R AHNE RESIDENCE --
;
STRUCT. CHK.
PRELIMINARY
_
LOT 8 OAK I
ELECT. CHK.
CLIENT APPROVAL
-RIDGE
AS1"ErY I�tCUNTAI! VIEW SUDDIVISI(�ly I
EAGLE COUNTY CQLO (t R Gv
PIPING CHK.
APPROVED FOR CONSTRUCTION
INSTR. CHK.
REVISED AND APPROVE[
FOR CONSTRUCTION REV
1
CIVIL CHK.I
JOB NO.
DATE
I TY
I SCALERAW
NOT APPROVED FOR CONSTRUCTION
DESTROY ALL PRINTS BEARING
UNLESS SIGNED AND DATED.
EARLIER DATE AND/OR REVISION
MAABER
4454
9/ 5 �a 4
�I/�IS
IV O T ED
!
l CIr I
_I
t