HomeMy WebLinkAbout109 Eagle Ct - 211106402002EAGLE COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH
PLEASE`CALL FOR`FINAL P. 0. Box 850 - 550 Broadway PERMIT MUST BE POSTED
INSPECTION BEFORE COVERING Eagle, Colorado 81631 AT INSTALLATION SITE
ANY PORTION OF INSTALLED SYSTEM
328-7311 or 949-5257 or 927-3823 PERMIT NO. N 635
OWNER: Siimonds/Wayes ADDRESS: PQ Rnx 33 Eagle
SYSTEM LOCATION: 705 Cedar Court Gypsum
LICENSED INSTALLER: Lei Frimml
LICENSE NUMBER:
**CONDITIONAL INSTALLATION APPROVAL is hereby granted for the following:
MINIMUM REQUIREMENTS:Q gallon septic tank or aerated treatment unit.
Absorption area or dispersal area computed as follows:
j
PERCOLATION RATE: / inch in minutes.
Absorption Area per Bedroom 2�o sq. ft.
No. of Bedrooms 3 x -Z Z U sq. ft. minimum requirement per bedroom
_ &(00 total sq. ft. minimum requirement.
SPECIAL REQUIREMENTS:
DATE: 8 29 83
INSPECTOR: Sid Fox
**CONDITIONS:
1. All installation must comply with all requirements of the County Individual Sewage
Disposal System Regulations, adopted pursuant to authority granted in 25-10-104,
C.R.S. 1973, as amended.
2. This permit is valid only for connection to structures which have fully complied
with County zoning and building requirements. Connection to or use with any
dwelling or structure not approved by the building and zoning departments shall
automatically be a violation of a requirement of the permit and cause for both
legal action and revocation of the permit.
3. Section III, 3.21 requires any person who constructs, alters, or installs an
individual sewage disposal system to be licensed according to the Regulations.
FINAL APPROVAL OF SYSTEM: No system shall be deemed to be in compliance with the Eagle
County Individual Sewage Disposal System Regulations until the installed system is
approved prior to covering any part.
Installed Absorption or Dispersal Area: Z� sq. ft.
Installed Septic Tank:
Design Engineer of System: N Wk
gallons. Degrees: Zo D Feet:
Installer of System: f (Z')yy\Vy\k Lk(,e, e s Phone:
Septic tank cleanout to within 12" of final grade or
aerated access ports above grade? Yes No
Proper materials and assembly? Yes No
Compliance with permit requirements? Yes_ No
Compliance with County/State regulations requirements? Yes
COMMENTS:
No
(Any item checked "No" requires correction before final approval of system is made.
Arrange a re -inspection when work is completed.
DATE: b INSPECTOR:
RE-INSPECTI N DOE: INSPECTOR:
J
"_:...... nF:^ZC - _AGLE
COL�:T`'
Ed.gie'
Color _do. Slo31
NO
PER`?IT APPLIC,TI0 7 =E
S150.!)0
"O--',?
_
P^RCOI�ITZO`: 7S� FFE $:0.00
NAME OF MN -,,ER: rrn.aa
cap --\T ,4,e5
ADDRESS: ` �3
t Ac��-e
�U`
PHO.E: 3 �a �' ��•ri �'
NA`tE OF APPLICANT (if different from owner):
ADDRESS: PHONE:
DESIGN ENGINEER OF SYSTE-M (if applicable):
ADDRESS: PHONE:
PERSON RESPONSIBLE FOR INSTALLATION OF SYSTEM: (L�r*rcnn� ,7I.L
,. N C
Licensed Installer (see attached list): YES "rN_ NO
ADDRESS: PHONE:
PERMIT APPLICATION IS FOR: New Installation ( ) Alteration ( ) Repair
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Street/Rural Address: K)5- C-eZNr,
Lot Size:
Legal Description: S�.Av�tiZ2w S,O, kt 'J"
BUILDING OR SERVICE TYPE (check applicable category):
( Residential - Single Family ( ) Residential Quadplex
( ) Residential - Duplex ( ) Commercial (state usage)
( ) Residential - Triplex
NUMBER OF PERSONS: 13
WASTE TYPES (check applicable categories):
( ) Commercial or Institutional
( ) Non -Domestic Wastes
( ) Garbage Disposal
Automatic Washer
( ) Other
TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED:
NUMBER OF BEDROOMS: 3
Dwelling
( ) Transient Use
( ) Dishwasher
( ) Spa Tub
Septic Tank
( ) Composting Toilet
(
)
Incineration Toilet
( )
Vault Privy
( ) Greywater
(
)'
Chemical Toilet
( )
Pit Privy
( ) Aeration Plant
(
)
Recycling, Potable Use
( )
Other
(
)
Recycling, Other Use
WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE: YES ( ) NO (`�)
IS SYSTEM DESIGNED FOR LESS THAN 2,000 GALLONS PER DAY: YES (`) NO ( )
WASTEWATER FLOW REDUCTION PLAN: YES ( ) NO (�
(16 Ye.s, see attached tuastaoatetc 6tow teduction methods)
NOTE: The Env.itconmenta2. Health 066 icvL may heduce the tequ i;ted absotrpti.on atcea upon
appnovat o6 an adequate wastewater. {stow neduetion ptan.,
SOURCE AND TYPE OF WATER SUPPLY: ( ) Well ( ) Spring ( ) Creek/Stream
Give depth of all wells within 200 feet of system:
If supplied'by community water, give name of supplier:
SIGNATURE: \Vvsn� DATE: ay 3
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
INFORMATION BELOW TO BE FILLED OUT BY ENUIRON&fENTAL HEALTH OFFICER:
GROUND CONDITIONS: PeAcent Ground Stope
Depth to Be&Lo ck (peg 8' Pno {site Hote )
Depth to GJLoundwateh. Tab.2e
SOIL PERCOLATION TEST RESULTS:, Minuta peA inch in Hote #1
Minutes peA inch to Hote # 2
Minutes pen -inch to Hate # 3
FINAL DISPOSAL BY: -
( ) Ab.s onpti,on T tench, Bed on PZt ( ) EvapotAans p Zta aon
( ) Above Ground D,i speAsaE ( ) Sand FZUeA
( ) Un&c g.tound D.ispe,�,saE ( i WastewatvL Pend
( ) OtfLCll
Amou;Lt Paid: a 0 C7 -0 C)
P.ec� ipt Nwnbe o 0 0 `� Date:
(Env. Health Department - Rev. 4-07-83)
EAGLE COUNTY memorandum
To: Subject:
Simonds/Hayes ISDS Permit #635
From: File No.: Date:
Environmental Health Office September 13, 1983
This is to inform you that your ISDS Permit #635 has been finalized and signed off
by Sidney Fox on August 30, 1983.
I am enclosing a copy of this completed permit for your records.
-- Lorraine Funke, Secretary
Environmental Health Office
Eagle County
/if
Enc.
PERCOLATION TEST FEE: Sc-.,)
I.S.D.S. APP. ..
OWNER:
LEGAL DESCRIPTION: e
RURAL ADDRESS:
TYPE OF DUELLING: =` OF BEopn(1MS:
DATE OF PERCOLATION TEST: �7^ < TYPE OF SOIL:
TEST HOLES PRESOAKED? Yes No
TIME
WATER DEPTH
INCHES OF FALL
RATE
1
2
3
1
2
3
1
2
3
1
2
3
u
i
-
PERCOLATION RATE: -,4,
RECOMMENDED MINIMUM SEPTIC TANK SIZE:
i
RECOMMENDED MINIMUM LEACH FIELD SIZE: %mod s'
RECOMMENDED MINIMUM SQUARE FOOTAGE PER BEDROOM: �= 5
Site has been reviewed and tested for percolation rate.
Date Environmental Health Officer
COMMENTS:
�? ..ems v� , <%C ✓� � � `Z, v � S S!/ �� F � - -
,JOB NAME
CC-X)T--r
JOP P,40�
BILL TO
DATE STARTED
DATE COMPLETED
DATE BILLED
L
6 q 02 — Wz
JOB COST SUMMARY
TOTAL SELLING PRICE
TOTAL MATERIAL
Yo
A 21 14-
PERMIT No. 6-35
To jar L R��
OWNER: -S4ffl8iids/ftye-s-
P.O. Box 33 - Eagle, CO
6COICR591e, COLST-
LOCATION: IM Cedar-4,eu - Gypsum, Colorado
Slaughter Subdivision
INSTALLER: Les Frimml
SIZE OF TANK: 1,000 gallons Degrees: 100
DWELLING: Single family - 3 bedrooms x 250
PERC RATE: one inch/5 minutes (750 sq.ft.)
Lto
060
- Feet: 40'
sq.ft.
TOTAL LABOR
INSURANCE
SALES TAX
MISC. COSTS
TOTAL JOB COST
GROSS PROFIT
LESS OVERHEAD COSTS
% OF SELLING PRICE
NET PROFIT
Ilia I Izeci z5/ju/63 BY: Sid Fox
JOB FOLMF-R Produ J>'axe
6
Printed in U.S.A.
\»C
�:� 7 f
*wft
' /��,
� \\\§�
S «�w-
z «4 /�:
��.�/
��� e.=
M
0
.JJ��
EAGLE COUNTY DEPARTMENT OF ENVIRONMENIAL HEALTH
i
PLEASE CALL FOR FINAL P. 0. Box 850 - 550 Broadway
INSPECTION BEFORE COVERING Eagle, Colorado 81631
ANY PORTION OF INSTALLED SYSTEM
328-7311 or 949-5257 or 927-3823 PERMIT NO. N ° 68 3
PERMIT MUST BE POSTED
AT INSTALLATION SITE
OWNER: Aldo & Judy Noriega. ADDRESS: Box 354 - Edwards, CO 81632
SYSTEM LOCATION: Lot #2 - Cedar Court - Gypsum
LICENSED INSTALLER: Aldo Noriega/Les Frimml LICENSE NUMBER: 84-08
**CONDITIONAL INSTALLATION APPROVAL is hereby granted for the following:
MINIMUM REQUIREMENTS: 1,000 gallon septic tank or aerated treatment unit.
Absorption area or dispersal area computed as follows:.
PERCOLATION RATE: one inch in 10 minutes.
Absorption Area per Bedroom 215 sq. ft.
No. of Bedrooms 3 x 215 sq. ft. minimum re 'cement per bedroom
645 total sq. ft. minimum requir ment
AIL ^wf, ooe�-
SPECIAL REQUIREMENTS: Need to the
SEPTIC TANK PRIOR TO POUR.
DATE: 10/10/84 INSPECTOR:
**CONDITIONS:
CALL FOR INSPECTION OF
1. All installation must comply with all requirements of the County Individual Sewage
Disposal System Regulations, adopted pursuant to authority granted in 25-10-104,
C.R.S. 1973, as amended.
2. This permit is valid only for connection to structures which have fully complied
with County zoning and building requirements. Connection to or use with any
dwelling or structure not approved by the building and zoning departments shall
automatically be a violation of a requirement of the permit and cause for both
legal action and revocation of the permit.
3. Section III, 3.21 requires any person who constructs, alters, or installs an
individual sewage disposal system to be licensed according to the Regulations.
FINAL APPROVAL OF SYSTEM: No system shall be deemed to be in compliance with the Eagle
County Individual Sewage Disposal System Regulations anti] the installed system is
approved prior to covering any part. Z Z c�5 3 S )( 3 1
Installed Absorption or Dispersal Area: sq. ft.
Installed Septic Tank;
Design Engineer of System:
Installer of System:
gallons. Degrees:
11
Feet:
Phone:
Septic tank cleanout to within 12" of final tj4de or
aerated access ports above grade? Yes No
Proper materials and assembly? Yes No
Compliance with permit requirements? Yes No
Compliance with County/State regulations requirements? Yes No
COMMENTS:
t,L��r..rvMr� ®4-CA-erqC A I
(Any item checked "No" requires correction before final approval of system is made.
Arrange a re -inspection when work is completed.)
DATE: / Z Z4 -�� f INSPECTOR: gee-,
RE -INSPECTION DATE: INSPECTOR:
RETAIN WITH RECEIPT RECORDS PER NO. NO- 683
CHARGES
Percolation Test = $50.00
Permit Fee (includes final inspection) _
ALL CHECKS OR MONEY ORDERS ARE TO BE
MADE PAYABLE TO: EAGLE COUNTY
Name of Applicant: Aldo Noriega
Name of Owner: Aldo & Judy Noriega
Amount Paid: $200.00 (9/28/84)
Receipt Number: C-0204
Cashier: Lorraine Funke
White and Pink Copies - Environmental Health Department Green Copy - Applicant/Owner
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
u EN'VIRONMENTAL HEALTH OFFICE - EAGLE COUNTY
% P.O. Box 850
' Eagle, Colorado 81631 No. pa C :
PERMIT APPLICATION FEE: $150.00 328-7311 PERCOLATION TEST FEE: $50.00
NAME OF OWNER:
ADDRESS: S ,�
NAME OF APPLICANT (if different from owner):
ADDRESS:
DESIGN ENGINEER OF SYSTEM (if applicable):
ADDRESS:
PERSuo i rn')x v v ill vie i JTALIATION OF SYST
Licensed Installer (see attached list)
C�P_) 81G32PHONE : 9 d, -3 % -,
5z4 —'7y73
PHONE:
PHONE:
ADDRESS: PHONE: 2- G ?3 G:,
PERMIT APPLICATION IS FOR: (l New Installation ( ) Alteration ( ) Repair
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Street/Rural Address:
Lot Size: jb
Legal Description: f }%c1j�i2i� �'LAUC'1�7c
BUILDIN2/OR SERVICE TYPE (check applicable category):
( Residential - Single Family
( ) Residential - Duplex
( ) Residential - Triplex
NUMBER OF PERSONS: 4
WASTE TYPES (check applicable categories):
( ) Commercial or Institutional
( ) Non -Domestic Wastes
( ) Garbage Disposal
(� Automatic Washer
( ) Other
TYPE OF., INDIVIDUAL SE14AGE DISPOSAL SYSTEM PROPOSED:
( ) Residential _ Quadplex
( ) Commercial (state usage)
NUMBER OF BEDROOMS:
( ) ])welling
( )/Transient Use
'I -KID'
Dishwasher
( ) Spa Tub
3
(
✓)
Septic Tank
(
) Composting Toilet
(
)
Incineration Toilet
(
)
Vault Privy
(
) Greywater
(
)
Chemical Toilet
(
)
Pit Privy
(
) Aeration Plant
(
)
Recycling, Potable Use
(
)
Other
(
)
Recycling, Other Use
WILL
EFFLUENT BE DISCHARGED
DIRECTLY INTO WATERS OF
THE STATE:
YES ( ) - NO
IS SYSTEM DESIGNED FOR LESS THAN 2,000 GALLONS PER DAY: YES (� NO ( )
WASTEWATER FLOW REDUCTION PLAN: YES ( ) NO ( )
(I6 yeas, see attached wastewatet {stow neduc ion meth.octs)
NOTE: The Env.itconmenta,2 Health 044iceA may teduee the %equiAed absa.tption area upon
appnova.2 o4 an adequate waustewaten 4tow teducti.on ptan.
SOURCE AND TYPE OF WATER SUPPLY: ( ) Well ( ) Spring ( ) Creek/Stream
Give depth of all wells within 200 feet of system: '70WIJ
If supplied by community water, give name of supplier: 01, S� A S 0A" I
SIGNATURE: DATE: SQL , R-
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -�
-r - -
INFORMATION BELOW/ TO BE FILLED OUT B NVIROMJENTAL HEALTH OFFICER:
GROUND CONDITIONS: PeAcent Gnound Stope
Depth to Be&Lo ck (pet 8' Pno bite Hote )
Depth to Gnoundwaten Tabte a X
SOIL PERCOLATION TEST RESULTS:. inute/s peA inch tin Hate 1
to Afinute�s pen inch to Hate # 2
FINAL DISPOSAL By: /,0 Minutes pen inch to Hote #3
(>'T' Absonpti,on Tneneh, Bed on Pit ( ) Evapottcanspi)Lation
( ) Above Gnound Dipeuat ( ) Sand FiZtek
( lj Undengnound DZspeu a2 ( ) Wastaoaten Pond
( ) Other.
Amount Paid: Receipt Nwnben � (:���.���"I Date:
NOTE.' Site Plan must be atta`ciied to appl1cat ion
.
(Env. Health Department - Rev. 4-07-83)
C
REPAIR PERMIT APPLICTAION
FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEMS
A permit fee of $150.00 shall be charged for alteration, enlargement or any repair
involving alteration of an existing sewage disposal system. This fee is authorized
by Eagle County Individual Sewage Disposal System Regulations adopted and effective
March 27, 1980.
For minor repairs of less than $100.00 for maintenance of the individual sewage
disposal system, no fee shall be required.
A percolation test fee of $125 shall be charged for all new leach fields on
repair permits. Percolation testing may be waived at the discretion of the
Environmental Health Officer on certain repair cases where prompt action must
be taken to prevent a health hazard.
IF PRESENT SYSTEM IS PRE-EXISTING, NON -CONFORMING, A NEW SYSTEM SHALL BE INSTALLED
COMPLYING WITH ALL CURRENT REGULATIONS. IF A NEW SYSTEM IS REQUIRED, ALL FEES ARE
APPLICABLE.
DESCRIPTION OF PROBLEM/MALFUNCTION: �< !vim
TYPE AND SIZE OF SYSTEM PRESENTLY IN USE: /
,t-j-'-- -
DATE PRESENT SYSTEM 14AS INSTALLED: / ;�_ — - R C
PERMIT NUMBER FOR ORIGINAL SYSTEM, IF A PERMIT WAS ISSUED BY THIS DEPARTMENT : #
SITE PLAN BELOW SHOWING PRESENT SYSTEM COMPONENTS:
OWNER OF SYSTEM: ,-I0 dJ
ADDRESS: e4Q1P j PHONE:
APPLICANT: 5P&I t=
ADDRESS: PHONE:
DATE:
INDIVIDUAL S
949-5257 Vail
ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY
P. 0. BOX 179
EAGLE, COLORADO 81631
328-7311 Eagle
Number: 3266
927-3823 Basalt
PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $125.00
NAME OF OWNER -
MAILING ADDRESS:
- NAME OF APPLICANT (If. different from owner):
ADDRESS:
DESIGN ENGINEER OF SYSTEM (If applicable):
ADDRESS:
PERSON RESPONSIBLE FOR INSTALLATION
LICENSED INSTALLER: ( ) YES
ADDRESS:
FAMzW� -I
PHONE:
PHONE:
OF SYSTEM:
( -_ -NO
PHONE:
PERMIT APPLICATION IS FOR: ( ) NEW INSTALLATION ( ) ALTERATION ( L4—RE`PAIR
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Physical Address: 112!� L ed Ele CZ:e
Parcel Number: of S
Legal Description:
ze:
BUILDING OR SERVICE TYPE (Check applicable category):
Residential - Single Family ( ) Residential - Fourplex
( ) Residential - Duplex ( ) Commercial (Type)
( ) Residential - Triplex
NUMBER OF PERSONS: NUMBER OF BEDROOMS:
WASTE TYPES Check applicable categories):
Commercial or Institutional ( Dwelling
( ) Non -Domestic Wastes ( ) Transient Use
( ) Garbage Disposal ( ) Dishwasher
( ) Automatic Washer ( ) Spa Tub
( ) Other (Specify):
TYPE OF INDIVLDUAL SEWAGE DISPOSAL SYSTEM PROPOSED:
Septic Tank Composting Toilet ( ) Incineration Toilet
( ) Vault Privy ( ) Greywater ( ) Chemical Toilet
( ) Pit Privy ( ) Aeration Plant ( ) Recycling, Portable Use
( ) Other ( ) Recycling, Other Use
WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE: ( ) YES NO
IS SYSTEM DESIGNED FOR LESS THAN 2,000 GALLONS PER DAY: ( ) YES ��FNO
WATER CONSERVATION PLAN: ( ) YES ( ) NO
NOTE: The Environmental Health Office may reduce the required absorption area upon
approval of an adequate water conservation plan.
SOURCE AND TYPE Or WATER SUPPLY: ( ) Well ( ) Spring' ( ) Creek/Stream
Give depth of all wells within 200 feet of system.
If supplied by community water, give name of suppl i er:,7b\NN c7p 0Aj pse 10_1
SIGNATURE:17
�� _ ,-Z DATE: _ -- 7r c
INFORMATION BELOW TO BE FILLED OUT BY ENVIRONMENTAL HEALTH OFFICER:
GROUND CONDITIONS: Percent ground slope
Depth to Bedrock (Per 8' profile hole
Depth to Groundwater table
SOIL PERCOLATION TEST RESULTS: Minutes per inch in Hole #1
Minutes per inch in Hole #2
Minutes per inch in Hole #3
FINAL DISPOSAL BY:
Absorption Trench, Bed or Pit ( ) Evapotranspiration
( ) Above Ground Dispersal ( ) Sand Filter
( ) Under Ground Dispersal ( ) Wastewater Pond
( ) Other
AMOUNT PAID: RECEIPT NUMBER DATE:
CHECK NUMBER CASHTFR-
NOTE: SITE PLAN MUST BE ATTACHED TO APPLICATION.
MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER".
(Environmental Health Dept. - Rev. 4/88)
vc
L PERCOLATION TEST
ENVIRONMENTAL HEALTH DEPARTMENT
Eagle County
FEE: $50.00 ISDS APPLICATION NO.
OWNER: L.'TVC% Iq
LEGAL DESCRIPTION: 2 O
RURAL ADDRESS: l)T 2 - (C042 6',,r yin �/iluc'
TYPE OF DWELLING: NUMBER OF BEDROOMS:
DATE OF PERCOLATION TEST: I V -TYPE OF SOIL: !3 / 4_.� e
TEST HOLES PRE-SOAKED: YES ✓ NO
TIME
WATER DEPTH
INCHES OF FALL
RATE
1
2
3.
1
2
3
1
2
3
1
2
3
3
9'
a
d-1 P4.1
r
' L-
-L—
3
° Z_
a�
L
PERCOLATION RATE:
RECOMMENDED MINIMUM SEPTIC TANK SIZE:
RECOMMENDED MINIMUM LEACH FIELD SIZE: S�
RECOMMENDED MINIMUM SQUARE FOOTAGE PER BEDROOM: a15 1
SITE HAS BEEN REVIEWED AND TESTED FOR PERCOLATION RATE.
Environm ealth ficer Date COMMENTS: CA1\ -&i2 o°rvsnc�c,i�'. Z SP- Tt-e-- 4AJ_Ic P(L cin
Rev. 5/31/84
• EAGLE COUNTY
551 Broadway
Eagle, Colorado 81631
(303) 328 7311
October 10, 1984
Mr. Aldo Noriega
. ` Box 354 .
Edwards, Colorado 81632
.Dear Mr. Noriega:
Enclosed is your ISDS Permit #683 for property located on
Lot #2, Cedar Court in Gypsum, Colorado. The information on
the permit application indicates that the system will be owner/
agent installed. Therefore, you will be responsible for the
installation of the system.
This green copy of the ISDS Permit must be posted on the installation
site. You must call our office for final inspection before covering
any portion of the installed system. We can be reached at 328-7311,
extension 238.
If you have any questions, please contact our office. -
Sincerely,
Lorraine Funke, Secretary
Environmental Health Office
Eagle Cpunty
/if
Enc.
Board of County Commissioners Assessor Clerk and Recorder Sheriff Treasurer
P.O. Box 850 P.O. Box 449 P.O. Box 357 P.O. Box 359 P.O. Box 479
Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631
.. r
tAULL C OUNTY
551. Broadway
Eagle, Colorado 81631
(303) 328 7311
December 28, 1984
Mr. Aldo Noriega
Box 354
Edwards, Colorado 81632
Re: Individual Sewage Disposal System Permit A683 for property
located on Lot 2 - Cedar Court - Gypsum, Colorado
Dear Mr. Noriega:
On Thursday, December 27, 1984 I came out to the above referenced
property to inspect your newly installed septic system and found it
to be completed and covered over.
Before I can give final approval of the septic system, I must have
copies of any receipts for gravel purchased, etc., and copies of
any pictures that may have been taken of the installed system before
being covered over.
If you have any questions, please call me.
Sincerely,
Erik W. Edeen
Environmental Health Officer
EAGLE COUNTY
EWE/ 1f
cc: Town of Gypsum
Board of County Commissioners Assessor Clerk and Recorder Sheriff Treasurer
P.O. Box 850 P.O. Box 449 P.O. Box 357 P.O. Box 359 P.O. Box 479
Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631
2
—V- IVi'ICPIO IHN VI. B"Izz
'DATE OF ORDER DATE SHIPPED CUSTOMER ORDER NO. SHIP VIA \ / TERMS
SHIP TO
GLENWOOD
SUPPLY COMPANY
SOLD TO UNI • ERSAL
_. - Uht
CORP
P.O. BOX 988 • 2502 STATE HIGHWAY 82 0148 264 ROAD
GLENWOOD SPRINGS, COLORADO 81602 RIFLE, COLORADO $1650
J (303) 945-2331 MOM 6?6S19n
QUANTITY
ORDERED
UNIT
DESCRIPTION
Q HIPPED
UNIT PRICE
AMOUNT
fd Ll
0 4/ 5 mX
- f
+t3stS '
SUB -TOTAL CODE;
`j -3- /
STATE SALES TAX
I
CODE; COUNTY SALES TAX
I
FREIGHT'
INVOICE TOTAL
�— THIS AMOUNT
/PLEASE PAYIG-
13-!;�
INVOICENUUUM/B/��ER /y�
O3[.'T L.J
Yr V, ULLUUFII
(ANNUAL PERCENTAGE RATE of 18%) will be charged if payment is received RECEIVED BY
after the tenth of the month following purchase. In the event that this account
becomes delinquent and it is necessary to make collection through the courts, the
purchaser agrees to pay all collection costs, including reasonable attorney fees and
court costs.
Returned material subject to a 15% handling charge.
(7 �D
�D
HIE & G r,0VY 1NC.
P. 0. Box E
cDEvRRDS, CO 81632
926.377 G 949-5167
3136
AMOUNT
STATEMENT Y / DATE kQ-
TO L 'V (✓ % C11
IN ACCOUNT WITH
TERMS
LA
I
O
o
STUART HALL CO.. INC. HANSAS CITY. MISSOURI 64108
i I
appc�
% �
41610 A)02,zG4
0.
Y
Z-/-8g
P. o. 8ov-
ScAl-rvz S�In
l v�
7 NO
�/- 3-ey earl -lam � L do -S!c!c �a�� uar ��lk o'►� �� ����
7 - Z/-S-°I - /'g/1 � �iGCt�r2 - 0• �!� �►'+'1_-� - :., f1��-%�1�
roil , F i c A to.. — /JO wtS urt..0
s K 8-7- Sr 174 4o (�. f'iGce,r lele .
. � j
Coo re- T
�- qv Tr,,►ci �u C bPla, ad Pc.6 vC etf(u vL
3 a,
3—a�-qo
/lNStuC2
�D
rEAGLE COUNTY
551 Broadway
Eagle, Colorado 81631
(303) 328 7311
July 10, 1985
Mr. Aldo. Noriega _
P.O. Box 354
Edwards, CO 81632
RE: ISDS Permit #683
Dear Mr. Noriega,
This is to inform you that your I.SDS Permit #683 has been finaled
by Erik Edeen, Thank you for providing us with the necessary
receipts for pipe, gravel etc. This was required because your
system was covered over without being inspected first.
Again, thank you for your cooperation. A copy of your permit is enclosed.
Sincerely,
A6 lJ
Gail Parker, Secretary
Environmental Health Office
EAGLE COUNTY
/gp
Board of County Commissioners Assessor Clerk and Recorder Sheriff Treasurer
P.O. Box 850 P.O. Box 449 P.O. Box 537 P.O. Box 359 P.O. Box 479
Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631
EAGLE COUNTY
551 Broadway
Eagle, Colorado 81631
(303) 328 7311
June 11, 1985
Aldo Norweigo
P.O. Box 354
Edwards, CO 81632
RE: ISDS Permit #683 for property located on Lot 2 - Cedar Ct.
Gypsum, Colorado
Dear Mr. Norweigo:
It has come to our attention that you have not responded to our
letter of December 28, 1984 regarding the final approval of your
septic system. A copy of .that letter is attached. Please send
us the required information as soon as possible so that we may
final out your permit.
If we can be of assistance to you in anyway, please co.ntact this
office.
Sincerely,
Erik W. Edeen
Environmental Health Officer
EAGLE COUNTY
EE/gp
cc: Town of Gypsum
Board of County Commissioners Assessor Clerk and Recorder
P.O. Box 850 P.O. Box 449 P.O. Box 537
Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631
Sheriff Treasurer
P.O. Box 359 P.O. Box 479
Eagle, Colorado 81631 Eagle, Colorado 81631
EAGLE COUNTY
551 Broadway
Eagle, Colorado 81631
(303) 328 7311
Certified Mail # P 239 757 271
1989 WORLD ALPINE
SKI CHAMPIONSHIPS
VAIL, BEAVER CREEK
January 27, 1989
Aldo Noriega
P. 0. Box 577
Gypsum, CO 81637
Malfunctioning individual sewage disposal system
Dear Mr. Noriega,
An inspection of your individual sewage disposal system on'January
20, 1989, revealed wastewater surfacing on the ground. This malfunctioning
leachfield must be repaired or replaced within 60 days receipt of this
notice. You must apply for a repair permit within 30 days receipt of this
notice. I have enclosed an application for a repair permit and a typical
diagram of a dry well.
Strict water conservation measures must be implemented until the
system is repaired and the septic tank should be pumped to provide for
storage capacity. The following repair specifications are recommended:
* Install a dry well between the existing septic tank and the
existing leachfield.
Diameter of excavation = 10 feet
Depth below inlet = 8 feet
Provide an overflow connection into the existing leachfield.
* The existing leachfield will be evaluated this spring to
determine if repairs are feasible.
If you do not agree with this repair specification, you may hire a
professional engineer to review the system and propose repair specifications
for our consideration.
If you have any questions concerning this matter, do not hesitate to
call or stop by.
Sincerely,
Sid Fox
Environmental Health Officer
SF/ar
cc: Town of Gypsum
Board of County Commissioners Assessor Clerk and Recorder Sheriff Treasurer
P.O. Box 850 P.O. Box 449 P.O. Box 537 P.O. Box 359 P.O. Box 479
Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631
C.", �D
EAGLE COUNTY
551 Broadway
Eagle, Colorado 81631
(303) 328 7311
March 9, 1989
Mr. Aldo Nori ega Ceejj f-�Ct � P -791i q 1 L10
P. 0. Box 577
Gypsum, CO 81637 _
RE: Malfunctioning Individual Sewage Disposal System
Dear Mr. Noriega,
This letter is a follow-up to my letter to you, dated January 27, 1989.
As you know, your sewage disposal system has malfunctioned, i.e.; effluent
from the leach field has surfaced on the ground. However, during my
inspection on March 7, 1989, I did not see effluent surfacing at that
time. Continued water conservation will help to minimize the surfacing
of :.effluent..from-: the„ leach field.
The deadline for repair remains March 31, 1989. However, if this
repair order presents a hardship to you, you must have the septic tank
pumped as soon as possible. The repair deadline can be extended as long
as storage capacity remains in the septic tank and effluent is not
surfacing on the ground. A pumped septic tank will provide temporary
storage while arrangements are made for repair of the leach field.
Please provide this office with proof.of septic tank pumping, i.e.;
a copy of the receipt for septic tank pumping. Enclosed is.:a copy of
licensed pumpers for your consideration. In addition, grey water can
not be thrown out onto the ground.
If you have any questions, do not hesitate to call.
Sincerely,
5d n/AK.
Sid Fox
Environmental
Health Officer
(9ar
xc: Trent Eichler
Town of Gypsum
Board of County Commissioners Assessor
P.O. Box 850 P.O. Box 449
Eagle, Colorado 81631 Eagle, Colorado 81631
Clerk and Recorder Sheriff Treasurer
P.O. Box 537 P.O. Box 359 P.O. Box 479
Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631
TM
1989 WORLD ALPINE
SKI CHAMPIONSHIPS
VAIL/BEAVER CREEK
Certified mail #
C �
EAGLE COUNTY
551 Broadway
• - Colorado 81631
CEI.
'
P 239 757 314
July 12,` 1989
Aldo Noriega
P.O Box 577
Gypsum, Co. 81637
Re: Malfunctioning individual sewage disposal system
Dear Mr. Noriega,
This correspondance is a follow-up to my previous letters to
you, dated January 27, 1989 and March 9, 1989. As you know,
your sewage disposal system has malfunctioned, ie: sewage
surfacing on the ground. My previous letter to you provided
you with 30 days to apply for a repair permit and 60 days to
repair the system. On April 4, 1989, 1 made an inspection of
your sewage disposal area and found that the leachfield was
not surfacing. Apparently the water conservation practices
minimized the potential for leakage of effluent. However, my
recent visit to the site revealed that the leachfield is once
again surfacing onto the ground, ie: sewage surfacing along
the north/west side.
ale
C' all
Board of County Commissioners Assessor Clerk and Recorder Sheriff Treasurer
P.O. Box 850 P.O. Box 449 P.O. Box 537 P.O. Box 359 P.O. Box 479
Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631
This malfunctioning sewage disposal system must be repaired.
the process to permit and repair this malfunctioning system
is as follows:
1. Pay the $150.00 repair, permit.fee
2. This office will issue a repair, permit and
specifications for repair.
3. Contact a licensed installer and contract to have the
repairs made —
4. Contact this office prior to covering the repair and
arrange for and inspection.
I have enclosed a list of licensed sewage disposal system
installers in Eagle County. If you do not respond to this
request within two business days of receipt of this notice,
legal action to abate this malfunctioning sewage disposal
will begin.
if you have any questions concerning this matter, please
call.
Sincerely,
Sid Fox
Environmental Health
Officer
xc: Town of Gypsum
encl.
SF/ar
EAGLE COUNTY"
551 Broadway
Eagle, Colorado 81631
(303) 328 7311
July 26, 1989
CERTIFIED MAIL #P 288 961 330
Mr. Trent Eichler
P.O. Box 814
Gypsum, CO 81637
Re: Malfunctioning Sewage Disposal System
Dear Mr. Eichler:
As you know, the individual sewage disposal system serving
109 Cedar Court appears to be malfunctioning.
I have notified Mr. Noriega of the requirement to repair the
system. Mr. Noriega wants to repair the leach field by
adding another length of pipe in the area of the existing pig
pen. My records indicate that Mr. Noriega has a leach field
easement on Lot 1 which he intends to utilize to repair his
system. Until this system is repaired, humans and animals
should avoid contact with the area where effluent is
surfacing. If we are going to solve this problem with
Mr. Noriegas' sewage system, your cooperation is
required.
If you have any questions concerning this matter, do not
hesitate to call.
Sincerely,
Sid Fox
Environmental Health Officer
SF/mk
xc: A. Noriega
B. Gates
Town of Gypsum
Board of County Commissioners Assessor
Clerk and Recorder
Sheriff
Treasurer
P.O. Box 850 P.O. Box 449
P.O. Box 537
P.O. Box 359
P.O. Box 479
Eagle, Colorado 81631 Eagle, Colorado 81631
Eagle, Colorado 81631
Eagle, Colorado 81631
Eagle, Colorado 81631
EAGLE COUNTY
551 Broadway
Eagle, Colorado 81631
(303) 328 7311
July 26, 1989
CERTIFIED MAIL ##P 288 961 330
Mr. Trent Eichler
P.O. Box 814
Gypsum, CO 81637
Re: Malfunctioning Sewage Disposal System
Dear Mr. Eichler:
As you know, the individual sewage disposal system serving
109 Cedar Court appears to be malfunctioning.
I have notified Mr. Noriega of the requirement to repair the
system. Mr. Noriega wants to repair the leach field by
adding another length of pipe in the area of the existing pig
pen. My records indicate that Mr. Noriega has a leach field
easement on Lot 1 which he intends to utilize to repair his
system. Until this system is repaired, humans and animals
should avoid contact with the area where effluent is
surfacing. If we are going to solve this problem with
Mr. Noriegas' sewage system, your cooperation is
required.
If you have any questions concerning this matter, do not
hesitate to call.
Sincerely,
�?Glllf
Sid Fox
Environmental Health Officer
SF/mk
xc: A. Noriega
B. Gates
Town of Gypsum
Board of County Commissioners Assessor Clerk and Recorder Sheriff Treasurer
P.O. Box 850 P.O. Box 449 P.O. Box 537 P.O. Box 359 P.O. Box 479
Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 , Eagle, Colorado 81631
�hd '� � /�`�' i' A ,aB�.` �� J �� \ q '�s.� F.tf .t`d �..�p� �'T' .c� .:� � li �} T l „S 7�t`�'& v • j5' . '9 � "�y � ✓ gA F � � 4��.�^
v
�✓' Imo' Ydm / 1, � ��'e.^`�. f � +if•3.
� IT �^�-/���.�.�i �
1 � !_, �'< /"�j/l � g /� .r � ��% ^ `! .' /j
.1 '�
/V
Y
% � 1-t '1�11�111�
a
el v. �pr�) , r
ql�101
�"&I.-6
6s //-4
MEMORANDUM
Date: January 17, 1990
To: ISDS File No. 683 ,<
From: Raymond P. Merr
Re: Status of Septic System/connected to 109 Cedar Court,
Gypsum, Colorado
On January 2, 1990 this office received a complaint
regarding surfacing sewage allegedly coming from the septic
system located in the easement adjacent to 109 Cedar Ct.
Several attempts were made to notify the responsible party, Mr.
Aldo Noriega, of the apparent problem. Contact was finally made
with his wife, Judy, on January 8, 1990 and she informed me Mr.
Noriega would be back on January 11, 1990 and would contact me
to set up a site visit. The complaintant was informed of this
schedule.
Mr. Noriega contacted me on January 11, 1990 and asked me to
meet him on site at 3:00 p.m. Upon my arrival he explained the
septic system design to me including the work he had done in
October which was expected to remedy the situation. (see file).
There was an accumulation of ice coming from an area about
15 feet from the nearest trench of his system. The ice appeared
to be fairly clear and a small flow of liquid was noted coming
from the side of the hill. The temperatures over the last
several days reached the 50 degree range. The problem is
compounded by the presence of a pig pen partially located on the
easement for the septic leachfield. The pigs have eliminated
the vegetation with the exception of a few cedar trees, thus
significantly reducing the ability of any leaching effluent to
be absorbed by plants.
Mr. Noriega and I discussed many scenarios which could be
causing the seepage as well as preliminary measures which could
be taken until more investigation could be done once weather
permitted. One of the measures to be taken is to block the flow
to the farthest trench forcing the effluent into the newly
constructed seepage pit. Another measure which will be taken is
to re -survey the pipes to assure they are level or slightly
sloping toward the seepage pit. Mr. Noriega informed me that he
would keep me informed of these modifications.
I am still not convinced that the liquid surfacing is due to
a failing septic. It may be from surface drainage going below
ground momentarily and surfacing out the side of the hill. It
may, however, be coming from the leachfield following a channel
of least resistance through the trenches and out near the hill.
As the geology exhibits many large boulders, perhaps there is
insufficient soil in that area to properly absorb effluents.
There are many possibilities and Mr. Noriega is wanting to
correct the problem if it is his problem. I informed the
complaintant on January 12, 1990 of the progress.
MEMORANDUM
TO: ISDS File No. 683
FROM: Raymond P. Merry, R.1c
Environmental Health
DATE: March 29, 1990
RE: Complaint of grading on septic easement at Lot 1, Ceder
Court, Gypsum, Colorado
On March 26, 1990, I was asked by Mr. Noriega to inspect the
property on which his septic leach field easement is located.
Mr. Noriega said that his neighbor, Trent Eichler, who owns the
property on which the easement is situated, did a substantial
amount of grading on Friday, March 23, 1990. The reason
Mr. Noriega was so upset was because he is afraid his septic
absorption system will fail.
I took four photographs which attempt to show the grading which
was done. Mr. Eichler has a pig pen which is apparently
situated partially within the area designated for Mr. Noriega to
use as a leach field easement. The fence was apparently
installed a couple of years ago and the grading, which was
recently done, extends further into the rear of the lot. The
horizontal depth of the excavation toward the rear of the pig
pen area is approximately 8 - 10' and the horizontal distance
between the newly installed seepage pit and the side wall of the
excavation appears to be less than 101.
In Section 4.04.02 of the ISDS Regulations, it states "The
minimum horizontal distance required from cut banks and fill
areas to individual sewage disposal system components
discharging effluent into or onto the surrounding soil shall be
four times the height of the bank, measured from the top edge of
the bank." (See attached diagram.) The recently excavated area
significantly reduces the area specified for absorption and
increases the potential for Mr. Noriega's system to fail.
I informed Mr. Noriega that should his system fail, he would be
required to fix it as he is responsible for the proper operation
of his system. He was also informed that, in my opinion, the
situation regarding his neighbor's activities are civil in
nature.
RM/mk
4.04.02
MINIMUM HORIZONTAL DISTANCES BETWEEN COMPONENTS OF A
SYSTEM AND PHYSICAL FEATURES
1) Minimum horizontal distances from the various
components of a system to pertinent terrain
features, including streams, lakes, water --
courses, springs, wells, subsoil drains,
cisterns, water lines, suction lines, gulches,
dwellings, other occupied buildings and
property lines, shall be in accordance with the
following "Table of Minimum Horizontal
Distances in Feet Between Components of a
Sewage Disposal System Installed After November
15, 1973, and Pertinent Physical Features."
2) New wells, springs or potable water supply
suction lines and all other constructed units
listed in the "Table" shall be installed or
located in accordance with the minimum distance
requirements provided in the "Table" on the
following page.
3) The minimum horizontal distance required from
cut banks and fill areas to individual sewage
disposal system components discharging effluent
into or onto the surrounding soil shall be four
(4) times the height of the bank, measured from
the top edge of the bank. (See;diagram below)
4h
T,
h
Absorption Trench
31
,.4s
1
qp .- 0
Asa" �• •. ;� �' , ,► � �, .
Ok
:1 i
HWE A HKFY DKY!
/--o
THE EAGLE VALLEY ENTERPRISE
PRINTING and PUBLISHING
EAGLE/GYPSUM 328-6656 • AVON/VAIL 949-1650
,SOB NoQ
Go D
JOB NAME
!// D (,g e-1D o2��
DATE BILLED
OB L
BILL TO
DATE STARTED
PERMIT #683.
OWNER: Aldo Noriega
Box 354
Edwards, CO 81632
LOCATION: Lot- 2,,- Cedar Court - Gypsum, CO
INSTALLER: Owner
SIZE OF TANK: 1,000 gallons -
DWELLING- Mnhiin a..m„
DATE COMPLETED
1 oq Cep-f-•
i
Al
14
d
J
d
t
1
D A T
f �
PL AfQ -A p PT�
fit-
NI L! 7*� ] f
i
ICU% �5 4