HomeMy WebLinkAbout200 Big Pinon - 246502301002 - 0562IS VOIDEAGLE COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH PLEASE C51LI FOR FINAL P. 0. Box 850 - 550 Broadway INSPECTION BEFORE COVERING Eagle, Colorado 81631 AW PORTION OF INSTALLED SYSTEM 328-7311 or 949-5257 or 927-3823 OWNER: Michael & Terry Funner SYSTEM LOCATION: LICENSED INSTALLER: PERMIT NO. N2 - 56 2 PERMIT MUST BE POSTED AT INSTALLATION SITE ADDRESS: P.O. Box 52, Snowmass, CO 81654 Lot 2 - Laura J. Estates LICENSE NUMBER: **CONDITIONAL INSTALLATION APPROVAL is hereby granted for the following: MINIMUM REQUIREMENTS: /000 gallon septic tank or aerated treatment unit. Absorption area or dispersal area computed as follows: PERCOLATION RATE: _ - inch in ",>� minutes. Absorption Area per Bedroom s? 5' 0 sq. ft. No. of Bedrooms 3 x _ O sq. ft. minimum requirement per bedroom _ '757C3 total sq. ft. minimum requirement. SPECIAL REQUIREMENTS: PA;01%Rltj Sdr Need to install two 75' trenches for 1 Se. r DATE: Z 1 INSPECTOR:/� i� **CONDITIONS: 1. All installation must comply with all requirements of the County Individual Sewage Disposal System Regulations, adopted pursuant to authority granted in 25-10-104, C.R.S. 1973, as amended. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Connection to or use with any dwelling or structure not approved by the building and zoning departments shall automatically be a violation of a requirement of the permit and cause for both legal action and revocation of the permit. 3. Section III, 3.21 requires any person who constructs, alters, or installs an individual sewage disposal system to be licensed according to the Regulations. FINAL APPROVAL OF SYSTEM: No system shall be deemed to be in compliance with the Eagle County Individual Sewage Disposal System Regulations until the installed system is approved prior to covering any part. Installed Absorption or Dispersal Area: sq. ft. Installed Septic Tank: Design Engineer of System: Installer of System: gallons. Septic tank cleanout to within 12" of final grade or aerated access ports above grade? Yes No Proper materials and assembly? Yes No Compliance with permit requirements? Yes No Compliance with County/State regulations requirements? Yes Phone: No (Any item checked "No" requires correction before final approval of system is made. Arrange a re -inspection when work is completed.) DATE;, w INSPECTOR: INSPECTOR: r•. •t . r PE %°•'•IT t EE = $150 PE CCL:;TI�;; TEST FEE = S50 APPLICATION FOR iiIDI'lIDUr:LSE'::i.�iE DIS��S;1 SYSTE'' PER,''•IT E BOX C�ZO c;"ALE, COL0'1.1 - 0 O1C31 NAME OF Ol•!NER: Michael and Terry Funner ADDRI-:SS: P.O. Box 52 Snowmass Colo. 81654 NACU: OF APPLICANT (IF DIFFERE.'IT FROM O" IER): ADDRESS: DF.SIGN ENGINEER OF SYSTEM (IF APPLICABLE): ADDRESS: ;Io. qILA � PHO;IE: 927-4245 PHONE: PHONE: PERSON RESPONSIBLE FOR INSTALLATION OF SYSTEM: Michael Funner ADDRESS: p_n_ Rox 52 Snowmass Colo_ 81654 PHONE: 927-4245 P,RPIIT APPLICATIO"I IS FOR: (X } Nei•% Installation ( ) Alteration LOCATION OF PROPOSED FACILITY: County Eagle City or Town, if within City or Toi:rn Limits LEGAL DESCRIPTION: Lot 2 Laura J. Estates ( ) Repair Lot Size 2.8612 STREET (RURAL) ADDRESS: IS SYSTEM DESIGNED FOR LESS THAN 2,000 GALLONS PER DAY? ( x) Yes ( ) No BUILDING OR SERVICE TYPE: (Check applicable category) ( X) Residential - Single-family dwelling ( ) Residential - Triplex ( ) Residential - Duplex ( ) Residential - Quadpl,ex ( ) Commercial - State usage # Persons 2 % # Bedrooms 3 WASTE TYPES: (Check all applicable) ( ) Commercial or Institutional ( x) Dwelling ( ) Garbage Grinder ( ) Non -domestic wastes ( ) Transient Use ( x) Dishwasher ( ) Other ( X) Automatic Masher SOURCE AND TYPE OF I4ATER SUPPLY: (x) Well ( ) Spring ( ) Creek or Stream - Give depth of all wells within 200 feet of the system: (1) 120' (2) aprox. 120 If supplied.•by community water, give name of supplier: ..:TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: (X ) Septic Tank ( ) Aeration Plant ( ) Chemical Toilet i .1faUll, r"f'iVy .� j ?.�{�'�'.�vJi. �i tij iUi I:. �l. � �� - Ti=�_`�L l�iiig, � vi. C1v ��' Q.aZ--. ( ) Pit Privy ( ) Inci-neration Toilet ( ) Recycling, Other Use ( ) Greywater ( ) Other WILL EFFLUENT BE DISCHARGED DIRECTLY INTO WATERS OF THE STATE? ( ) Yes ( X ) No Signature - -E--� ;- Date 5/10/82 INFORMATIOid BELO!•! TO BE FILLED OUT BY ENVIRnivENTAL HEALTH OFFICER GROUND CONDITIOiIS: Percent Ground Slope: c2 Depth to Bedrock (per 8' Profile Hole): Depth to riroun.i.'iater Table: SOIL PERCOLATION TEST RESULTS: �?_O 1MPy Ninutes per inch in bole ilo. 1 ZU Minutes per inch in Hole No 2 Minutes per inch in Hole -No. 3 FINAL DISFCS%L oY: (yC) Absorption Trench, Bed or Pit ( ) Eva notransoiration ( ) Above Ground Dispersal ( ) Sand Filter ( ) Un-'erground Dispersal ( ) '.'!astei:iater Pond ciA t ROUTE FORM EAGLE COUNTY ENVIRONMENTAL HEALTH OFFICE Name Lk 8D, Q�t Date out d Application No. (Location) Please review the attached Individual Sewage Disposal System Permit Application and return it with this completed form to the Environmental Health Office. PLANNING: Complies with - . YES NO REVIEWED BY DATE Subdivision Regulations: V Zoning`Regulations: Recommend Approval: COMMENTS: BUILDING.: Complies with - Building Permit Applied For: Building Permit Issued: Recommend Approval: COMMENTS: YES NO REVIEWED BY DATE ENGINEER: Complies with - Roads: Grading: Drainage: Recommend Approval: YES NO REVIEWED BY DATE COMMENTS: ENVIRONMENTAL HEALTH: Complies with - Floodplain Permit Necessary: I.S.D.S. Regs. Compliance: Recommend Approval: COMMENTS: �� �'�CUVYI l�i/�l 111-Shc�i /`� IC7CJIn ." YES _ I NO I REVIEWED BY I DATE s I TELEPHONE 303/328-731-1 Boaid of County Commissioners Ext 241 Assessor Ext 202 Clerk and Recorder Ext 217 Sheriff Eagle: Ext 211 Basalt: 927-3244 Gilman: 827-5751 Treasurer Ext 201 Administration Ext 241 Animal Shelter 949-4292 Building Inspection Ext 226 or 229 Community Development Ext 226 or 229 County Attorney Ext 263 Engineer Ext 236 Environmental Health Ext 238 Extension Agent Ext 247 Library Ext 255 Public Health Eagle: Ext 252 Vail: 476-5844 Personnel Ext 241 Purchasing Ext 245 Road and Bridge Ext 257 Social Services 328-6328 EAGLE COUNTY Eagle, Colorado 81631 May 17, 1982 Mr. Michael Funner P.O. Box 52 Snowmass, Colorado 81634 Dear Mr. Funner: After reviewing your application for an Individual Sewage Disposal System on your property, Lot 2, Laura J. Estates, I note that we do not have a site plan attached to the application. We will need this site plan to attach to the application for routing to the Building, Planning and Engineering Departments for approval. Also, you must install two 75 foot trenches for your leaching area. if you have any questions, please call me. Sincerely, 1 ,Q Sid Fox Environmental Health Office /1f t A � TELEPHONE 303/32d7311 e Board of County Commissioners Ext 241 Assessor Ext 202 Clerk and Recorder Ext 217 Sheriff Eagle: Ext 211 Basalt: 927-3244 Gilman: 827-5751 Treasurer Ext 201 Administration Ext 241 Animal Shelter 949.4292 Building Inspection Ext 226 or 229 Community Development Ext 226 or 229 County Attorney Ext 263 Engineer Ext 236 Environmental Health Ext 238 Extension Agent Ext 247 Library Ext 255 Public Health Eagle: Ext 252 Vail: 476-5844 Personnel Ext 241 Purchasing Ext 245 Road and Bridge Ext 257 Social Services 328-6328 EAGLE COUNTY Eagle, Colorado 81631 May 27, 1982 Mr. Michael Funner P.O: Box 52 m Snowass, Colorado 81654 Dear Mr. Funner: Enclosed please find Individual Sewage Disposal System Permit #562 for property located;on Lot 2 - Laura J. Estates. The information on the permit application shows that the system will be owner installed; therefore, you are responsible for the installation of the system . The permit must be posted on the installation site. Please call our office for final inspection before covering any portion of the installed system, telephone 328-7311, extension 238. Sincerely, Lorraine Funke, Secretary Environmental Health Department /if Enc. j. The ground surfac shall be graded to ct precipita- tion or other outside ter fr the disposal area. The absorption area shall b r ected against erosion. k. The perforated ipe in the drain ld (County system only) shall be least 6 inches below the ou et invert of the sep tank. 8.2 Absorption Trench a. At least 2 trenches of near equal length shall be constructed with a length not exceeding 100 feet; a width not exceeding 3 feet; and a depth not exceeding 3 feet (unless approved by the Health Officer). A minimum 3-inch diameter disposal line shall be provided for each trench and shall be surrounded by clean, graded gravel or rock, broken hard burned clay brick, or similar aggregate. The material may range in size from 1/2 inch to 2-1/2 inches. Cinders, broken shell, and similar material are not recommended. The material shall extend from at least 2 inches above the top of the pipe to at least 6 inches below the bottom of the pipe. The top of the gravel shall be covered with untreated building paper, a thin 2 inch layer of hay or straw, or similar pervious material to prevent the gravel from becoming clogged by earth backfill. An impervious covering shall not be used, as this interferes with evapotranspiration at the surface. A distribution device providing uniform distribution shall be included. The bottom of the trench and the distribution lines shall be level or graded to comply with (b) below. b. Disposal lines composed of 12 inch lengths of 4 inch diameter agricultural drain tile, concrete pipe or vitrified clay sewer pipe shall provide joint openings between lengths of pipe of 1/8 to 1/4 inch in width. Each open joint shall be covered over the upper half of the joint opening. Perforated plastic lines of a minimum 3 inch diameter shall be fitted with tight joints and the performations shall be so laid that - 36 - a relatively even distribution of effluent over the system will occur. When, at the discretion of the Health Officer, it is necessary to maintain grade or alignment of the tile or pipe lengths, all tile or pipe lengths shall be placed on narrow grade boards which are securely staked. The grade of pipelines shall be from zero (0) inches to 4 inches per 100 feet. C. A final cover of soil suitable for vegetation at least 10 inches deep shall be placed from the top of the hay, straw, or other similar pervious material to the finished surface grade of an absorption trench or seepage bed. The final cover shall be graded to deflect runoff water away from the disposal area. In the case of an above -ground system, such as a mounded system, an impervious berm shall be constructed to prevent lateral flow of waste discharge outside of the absorption field. Machine tamping, rolling, or hydraulic compaction of final cover shall not be permitted; however, hand tamping may be allowed where necessary to stabilize the soil to prevent erosion or the intrusion of extraneous water. 8.3 Seepag Beds a. Seepa e beds shall be constructed with a lengt notexceeding 100 feet; a width not greater than A feet; nd a depth not exceeding 3 et (unless approved by th Health Officer). A 12-inch layer o /2 inch to 2-1/2 ' ch washed gravel shall be distributed even l over the e ire bed, with pipelines set at a depth to insure t ast 6 inches of gravel below and 2 inches of gravel above ac line. The bottom of the bed shall be level. A cc Bring of u treated building paper, straw, or similar faterial, shall b placed on top of the gravel, and of r final inspection, ba fill shall be placed over the be to a minimum depth of 10 inch The bottom in the bed d distribution lines shall be laid level or up to a 4;inch drop in 100 feet. - 37 - PERCOLATION TEST FEE: $50 1-1 I.S.D.S. P ,P. # OWNER: LEGAL DESCRIPTION: RURAL ADDRESS: TYPE OF DWELLING: , -�- -5ve # OF BEDROOMS: DATE OF PERCOLATION TEST: _� TYPE OF SOIL714 vef i r TEST HOLES PRESOAKED? ties �_ No �gJa4N!'e WATER DEPTH }INCHES OF FALL., PERCOLATION RATE: �z 0- e-,'T— 3 4C- dpS RECOMMENDED MINIMUM SEPTIC TANK SIZE: RECOMMENDED MINIMUM LEACH FIELD SIZE: 75-/ 4 RECOMMENDED MINIMUM SQUARE FOOTAGE PER BEDROOM: Site has been revievied and tested for percolation rate. -5/? Azy e---- , S,/ -,,i � Date Environmental eat icer COMMENTS: M/Alrj TPjw SCo' Sera c �JYr► /[C��irK)Sfo" n 0 Funner Lot 2 Laura JOE3 14AMI Estates JOB LOCATION BILL TO DATE STARTED DATE COMPLETED DATE BILLED R, -PA, 7Txk Ac)w-r, � cle--,� \lmn MAIE��C:, OT200'R(q PA,M 21260 &rtS Ili 9,ceff' 2qCs-02:3-CA-002 RECEIPT Date Received From Address �,-O, 5367 For Dollars 21 ACCOUNT HOWPAID AMT. OF ACCOUNT W- 0 CASH. JOE AW. PAID V OV CHECK BALANCE MONEY DUE ORDER fit By -j SK808 0 J013 NC ,