HomeMy WebLinkAbout152 Park Ave - 246511203004 - 0561ISEAGLE COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH PLEASE CALL FOR FINAL P. 0. Box 850 - 550 Broadway INSPECTION BEFORE COVERING Eagle, Colorado 81631 ANY PORTION OF INSTALLED SYSTEM 328-7311 or 949-5257 or 927-3823 PERMIT NO. N? 56 1 PERMIT MUST BE POSTED AT INSTALLATION SITE OWNER: Paul Adams/Clay Crossland ADDRESS: P.O. Box 55 Basalt, CO 81621 SYSTEM LOCATION: Lot 13 - Basalt Industrial Park _ LICENSED INSTALLER: LICENSE NUMBER: **CONDITIONAL INSTALLATION APPROVAL is hereby granted for the following: MINIMUM REQUIREMENTS:7,C-C gallon septic tank or aerated treatment unit. Absorption area or dispersal area computed as follows: Evapotranspiration System PERCOLATION RATE: Q inch in minutes. 1,120 sq.ft. Absorption Area per edroom � sq. ft. No. of Bedrooms f5k x sq. ft. minimum requirement per bedroom l"} total sq. ft. minimum requirement. DATE: 7 **CONDITIONS: 1. All installation must comply with all requirements of the County Individual Sewage Disposal System Regulations, adopted pursuant to authority granted in 25-10-104, C.R.S. 1973, as amended. 2. This permit is valid only for connection to structures which have fully complied with County zoning and building requirements. Connection to or use with any dwelling or structure not approved by the building and zoning departments shall automatically be a violation of a requirement of the permit and cause for both legal action and revocation of the permit. 3. Section III, 3.21 requires any person who constructs, alters, or installs an individual sewage disposal system to be licensed according to the Regulations. FINAL APPROVAL OF SYSTEM: No system shall be deemed to be in compliance with the Eagle County Individual Sewage Disposal System Regulations until the installed system is approved prior to covering any part. Installed Absorption or Dispersal Area: ll ® sq. ft. Installed Septic Tank: �� gallons. Design Engineer of System: } � - sw e Installer of System: Phone: Septic tank cleanout to within 12" of final grade or aerated access ports above grade? Yes No Proper materials and assembly? Yes No Compliance with permit requirements? 4s_ No Compliance with County/State regulations requirements? Yes No COMMENTS: (Any item checked "No" requires correction before final approval of system is made. Arrange a re -inspection when work is completed.) DATE: INSPECTOR: `:'-INSPECTION DATE: INSPECTOR: •111T V r•'—•1 6OX S 5 0 w E;"kGLE, C 0 L CPA 0 81631 . RERr IT t Ec = $150 FE COL:1TION' TEST FEE = S-50 APPLICATION' FOR 1NDIVIDUr`.L SE D1S. SAL SYSTE'•' PEPiIT . NAME *OF O,d,IER: f%^s lli0 \.iZOSS�avtc� ADDRESS: Lp-{ I;s - PHONE: f! NAME OF ADDRESS: APPLICANT (I--F DIFFE"ENT a0k FR011 01-111ER): !SC.N0Nf VN"eSe_Y" -fASSvc:-&--�es a. k St' C-A 30(01 &Letawoo j PHONE: gg T. Tq4 S DF.SIGJ ENGINEER OF SYSTEM (IF APPLICABLE): �X RMMMS iIIC • ADDRESS: Sol CGlneaejoA4.. sT•�&•Zi711ttWlM 9/6,01 PHONE: PERSON RESPONSIBLE FOR INSTALLATION OF SYSTEMM: Q�N�IC • ADDRESS: PHONE: Pr'.RMIT APPLICATION IS FOR: "Iew Installation LOCATION OF PROPOSED FACILITY: County 644d City or Town, if within City or To in Limits _ LEGAL DESCRIPTION: �.Q•r i3. AsAtr JAJ STREET (RURAL) ADDRESS: ( ) Alteration ( ) Repair Lot- Si ze A 444• 14 A rito A L. 00i4me IS SYSTEM DESIGNED FOR LESS THAN 2,000 GALLONS PER DAY? ( ) Yes (�► No BUILDING OR SERVICE TYPE: (Check applicable category) ( ) Residential - Single-family dwelling ( ) Residential - Triplex Residential - Duplex ( ) Residential - Quadplex Commercial - State usage WAMMd iV;% Persons "At �r # Bedrooms WASTE Y ES: (Check all applicable) ( Commercial or Institutional ( ) Dwelling ( ) Garbage Grinder ( ) Non -domestic wastes Transient Use ( ) Dishwasher ( ) Other ( ) Automatic hasher SOURCE MID TYPE OF 14ATER SUPPLY: ( ) W1el1 ( ) Spring ( ) Creel or Stream Give depth of all wells within 200 feet of the system: If supplied.,by community water, give name of supplier: ND • AR,K TYPE OF INDIVIDUAL SE14AGE bISPOSAL SYSTEM PROPOSED: � A% Septic Tank ( ) Aeration Plant ( ) Chemical Toilet ,. i - i t - .�aUll, r"Y'[.y3 -� 1 ?,..�!::.;J iUi! .1.L.a!i�' vJC ( ) Pit Privy ( ) Inci-nera ion Toilet ( ) Recycling, Other Use ( ) Greywater (x) Other r 1 MAIfp6a WILL EFFLUENT BE DISCHARGED DIRECTLY INTO HATERS OF THE STATE? ( ) Yes (%'°j No Signature Date .44 49L - �c :t is •!c 4c �c k �c ie �c k c h :� ;r t F � is �c �c * * t �t INFORMATION BELO BE FILLED OUT BY EN Rnm1ENTAL HEALTH OFFICER GROUND CONDITIOINS: Percent Ground Slope: Depth to Bedrock (per 8' Profile Hole): Depth to riroun.�,.,jater Table: SOIL PERCOLATION TEST RESULTS: Pinutes per inch in bole 111o. 1 Ninutes per inch in Hole No. 2 !1i nutes per i nch in Hole No. 3 FINAL DISPOSAL BY: ( ) -Absorption Trench, Bed or Pit ( ) Evapotranspiration ( ) Above Ground Dispersal ( ) Sand Filer ( ) Un-'erground Dispersal ( ) :!aste:'iater Pond ( ) 0t:-.er TELEPHONE 303/328-7311 Board of County Commissioners Ext 241 Assessor Ext 202 Clerk and Recorder Ext 217 Sheriff Eagle: Ext 211 Basalt: 927-3244 Gilman: 827.5751 Treasurer Ext 201 Administration Ext 241 Animal Shelter 949-4292 Building Inspection Ext 226 or 229 Community Development Ext 226 or 229 County Attorney Ext 263 Engineer Ext 236 Environmental Health Ext 238 Extension Agent Ext 247 Library Ext 255 Public Health Eagle: Ext 252 Vail: 476-5844 Personnel Ext 241 Purchasing Ext 245 Road and Bridge Ext 257 Social Services 328-6328 FAN Eagle, Colorado 81631 May 24, 1982 Paul Adams & Clay Crossland P.O. Box 55 Basalt, Colorado 81621 Dear Sirs: Enclosed please find an individual sewage disposal system permit #561 for property located on Lot 13 - Basalt Industrial Park. The information on the permit shows that proper precautions should be taken to insure that no encroachments should be upon the system by motor vehicles; ie., fence, railroad ties, etc. The permit must be posted on the installation site. Please call our office -for final inspection before covering any portion of the installed system, telephone - 328-7311, extension 235. If you have any questions, please contact us. Sincerely, t P Lorraine Funke, Secretary for Environmental Health Department /If Enc. P.S. Also enclosed is your receipt #5366 in the amount of $150.00 - ISDS Permit Application fee. SCHMUESER & ASSOCIATES, INC. i 201 CENTENNIAL STREET SUITE 306 GLENWOOD SPRINGS, CO 81601 (303) 945.5468 April29, 1982�- Mr. Erik Edeen Eagle County Sanitation P.O. Box 126 Eagle, CO 81631 RE: E/T System Design Dear Erik: Please find enclosed two (2) copies for your review and approval of the design for an evapotranspiration system for Lot 13, Basalt Industrial Park. The property is owned by Mr. Paul Adams and Mr. Clay Crossland. This is a somewhat unique situation in that we are serving a warehousing facility. The facility will be used as an overnight storage area and transfer of shipped goods. The design is based on a maximum .of three employees, but is fact only a single dis- patcher is anticipated. We also accounted for a transient population. Also please note that this facility is within the proposed Mid -Valley Metro District and will be served by central sewer facilities in the future. Please feel free to contact either Scott Leslie or myself if ad- ditional information is needed. Your prompt review is appreciated. Sincerely, SCHMUESER & ASSOCIATES, INC. Dean rdon, P.E. Princip'1 Engineer DWG/ln tl L'Of 66 1-�2eoee 111301 APR 3 a 1982 z bli ENVIRQNMENTAL HEALTH Roaring Fork Construction Box SS Basalt, Colorado 81621 (303) 927-3868 May 5, 1982 Erik Edeen Eagle County Sanitation P.O. Box 126 Eagle, CO 81631 Dear Erik, Enclosed, please find a check for $150.00 to cover the permit fee for our proposed evapotranspiration system for Lot 13, Basalt Industrial Park. Mr. Dean Gordon, of Schmueser & Associates, has sent two (2) copies of the design for your review and approval. If you have any questions regarding this system, please contact US. Very truly yours, Clay Crossland CC: ad encl. �` n d EM ROUTE FORM EAGLE COUNTY ENVIRONMENTAL HEALTH OFFICE 5- fi- a A, A a I Date'Routed APPlication No. Location Please review the attached Individual Sewage Disposal System Permit Application and return it with this completed form to the Environmental Health Office. PLANNING: Complies with - YES . NO ''.—''REVIEWED BY DATE Subdivision Regulations: Zoning`Regulations: Recommend Approval: COMMENTS: _ . BUILDING: Complies with - Building Permit Applied For: Building Permit Issued: Recommend Approval: COMMENTS: 1REVIEWED BY1� f®®CW��M�'�C ENGINEER: Complies with - Roads: Grading: Drainage: Recommend Approval: YES NO REVIEWED BY DATE X Se �( JC e� c k COMMENTS: l�� } 1 s,n"o.a_ Thri r J ;%.I:, —,t— as ��:�� ._L 4 L_1 ..: J_ L 1_ :.I — ENVIRONMENTAL HEALTH: Complies with - Floodplain Permit Necessary: I.S.D.S. Regs. Compliance: Recommend Approval: YES NO REVIEWED BY DATE COMMENTS: u56i Indus. Park I S2 i A � 14dams Lot 23 oasaiZ JOB NAM ,. JOB LOCATION BILL TO DATE STARTED COMPLETED LLC MX_W1A1n V2 PERMIT #561� _ 03 —may OWNER: d LOCATION: Lot 13 Basalt Industrial Park INSTALLER: Owner Schmeuser - Design Engineer SIZE OF TANK: 1,000 gallons DWELLING: Warehouse PERC RATE: Evapotranspiration System Finalized: 7-2-82 By: Rick Pylman DATE BILLED JOB COST SUMMARY TOTAL SELLING PRICE TOTAL MATERIAL V 0 I D PERMIT # 563 Duplicate of #561 /o/ /0 Q �6 - - 99kA xbtE4 uarpoav (JAvept., AvAl 1,4 :?p'jx%c' poe&larr.-'. SCHMUESER & ASSOCIATES, INC. 201 CENTENNIAL STREET + GLENWOOD SPRINGS, COLORADO 81601 (303) 945-5468 Dr��l ll� �a AST A3, FA ti`3 /-� o /0o l �c ' V _ ` Rews,on 54�1 L Drawn By Date 7 Appr.. f7! 27 Coss I 1. -All-materials, installation -practices, etc. to confrom to' County Individual Sewage Disposal System Regulations. 2. Gravel shall be 112" to 1 112" washed gravel. 3. Sand shall be 0.5 to 1.0 mm effective size. 4. The recommended seeding is Blue Grass e 4 to 6 lb5/1000 sq. ft. 5. The liner shall be Placed in a manner which will prevent injury to scuffing, penetration by foreign objects or dis- r----; tress from rough s rface. AC Yt-:;NTS 4� e r �1. Provide adequate s.:facwater diversion to assure that run- off does nut enter :.he evapo-transpiration bed, j 7. The solid PVC liner with no field splices is specified to provide additionai rrotection to the groundwater in the area. /D ( The use of Visquee,% shall not be, accepted. t The septic tank sn:'be made as watertight as possible to prevent groundwatc-r infiltration. The joint between tank - halves, the inlet G-d outlet and the joint around the risers shall all be tignt;i sealed with mastic or grout. A t =1 y. The shown location :.f the ET bed is only approximate. The bed shall be iocatt in the field so that it best fits the site and rueets ail .:istanc e requirements of the Count f 4,. Regulations.07 y 10. ";o portion of the ET bed shall be placed in fill, 11. Tice Enhn -En aty Sanitarian sall be otified prior to c0r,1P1eti0n of the tti so that it can be inspected to assure conformance with 11 ie plans. 12. Topsoil material be able to support revegetation and c j shall be graded tv -;eflect precipitation and surface water away from the dispCsal area. DESIGN p 1= ° Flow- 3 er, lu� =s x j5 GPCD 105 gallons per day use 15 i -':: to allow for truck drivers and other i transiertL Area= 150 GP-,' x 237 1110 ft.2 1 _ Provide =_: size 8.0 x 14 = 1120 ft.2 /�� M �� I � �= " �"_ _ _- _ - . ._ .. . - DEL_ ;♦ ; TES �' - - _� � _- I �= yl r= L�"�'�`i.it;�i"' {. i'�'.L�'�--t;;�.; ��`i�c-;�ii�i�•"�;•"i ; ; -'f`Y, titi'-"-�� ��♦ �:- .yT� y1- _ �- �+<f.'vf,•-` ;N.f�. � �`._ ;,. � — :'w � 'y. t:ra ` `i' tti `' j,•..,i=(.. �.r. .y=.;=,`7',���'`� ���•'C. ,` f .+.-. � s,f::'��. S :�;':...S y�..��c :�,tf t�.� ��� — _ - � ~ rT7 �• '�J • tl, a-� �-` � �t�'♦ �►_,:��.' �� ;. .•y�y-rjr.,!y.G :� r_n� Ya r:..r:?Y�y �' 7:.' .-.t4-_ f�i.• -r• !tf 'G{>r _ ,ti�M .4 •`br• - a 'yam i., va;l ;%.I3 w•.•r ;t .y ;i—G tl, IJ------------------- I 1 - I t > ;; ._ i , .,ram• _- _. ! i i M 4 SC�� MUESER & ASSOCIATES, INC. VAPC - % Q�Ipl umber Rev�s�o� Date 8yJob: b., l/l f \J ! �', / 2L 201 CENTENNIAL STREET -_ GLE-NWOOD SPRINGS, COLORADO 81601 L� f + Drawn By: CAa (303 945-5468 ���� � � li'�1����P�l�•� �� � �. - -- - - - - -- - I Date: - - - - - - -