Loading...
HomeMy WebLinkAbout726 Willits Ln - 246502300006posted EAGLE COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH Permit must be p Box 850 Ru.%V13 6th & Broadway Must call for final i nspecti o on location Eagle, Colorado 81631 before covering any part of installed system: 328-731 r ol" 949-5257 or 927-3823 Toll free Phone numbers (this does not constitute PERMIT N9 496 a hnilrlina nr nca narmitl Owner Donald am Roberta Boyer o r7,Z4- System Location Tract No. 47 - Willixxk Willits Lane Licensed mbrInstaller: * Conditional Construction approval is hereby granted for a 1 ,000 gallon xx Septic Tank or Aerated treatment unit. Absorption area (or dispersal area) computed as follows: Pere rate 1 inches in 10 minutes 600 sq. ft. absorption area per bedroom 200 sq. ft. # of bedrooms 3 x 200 sq. ft. minimum requirement May we suggest MINIMUM REQUIREMENTS: 1,000 gallon septic tank with minimum 600 sq. ft. leach field. Date April 29, 1981 Inspector Erik Edeen FINAL APPROVAL OF SYSTEM: No system shall be deemed to be in compliance with the Sewage Disposal Laws until the assembled system is approved prior to covering any part. X__ Septic Tank cleanout to within 12" of final grade or aerated access ports above grade. Proper materials and assembly. Adequate absorption (or dispersal) area. Adequate compliance with permit requirements. _Adequate compliance with County and State regulations/requirements. Date I Inspector _!��:,'d'*'=:�I� RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE * CONDITIONS: 1. All .installation must comply with all requirements of the County Individual Sewage Disposal Regulations, adopted pursuant to authority granted in 25-10-104, CRS 1973 amended 25-1-614, CRS 1973 2. This permit is valid only for connection to structures which have fully complied with County Zoning and building requirements. Connection to or use with any dwelling or structures not approved by the building and Zoning office shall automatically be a violation of a requirement of the permit and cause for both legal action and revocation of the permit. 3.28 3. Section III, XxIt requires any person who constructs, alters, or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications con- tained in the application of permit commits a Class I, Petty Offense ($500.00 fine - 6 months in jail or },-*H .", PLEASE RETURN THIS PORTION WITH YOUR SITE PLAN AND FEES 949-5257 ENVIRONMENTAL HEALTH BOX 850 EAGLE, COLORADO 81631 u if 'W. , 927 11 `may + aYgS fi'.+j PERMIT FEE = $75 PERCOLATION TEST FEE = $50 APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT NAME OF OWNER: ADDRESS: 7 . NAME OF APPLICANT (IF DIFFERENT FROM OWNER): ADDRESS: DESIGN ENGINEER OF SYSTEM (IF APPLICABLE): ADDRESS: NO. y �9 Y/4Z-3 PHONE: PHONE: PHONE: PERSON RESPONSIBLE FOR INSTALLATION OF SYSTEM: _,:: ADDRESS: 5�F �,,-s ha�rc PHONE: PERMIT APPLICATION IS FOR: (X) New Installation ( ) Alteration ( ) Repair LOCATION OF PROPOSED FACILITY: County City or Town, if within City or Town Limits LEGAL DESCRIPTION: —/ -c�c� A)o. -4- STREET (RURAL) ADDRESS: uj; L I ,+s5 Lot Size Sc�c yes 1S SYSTFM PFSTnR'Fr1 Fnp LFc.r, THAN 2,000 ^AI r ONS PER InAv? V 1 Yes ( ) n!o BUILDING OR SERVICE TYPE: (Check applicable category) (x) Residential - Single-family dwelling ( ) Residential - Duplex ( ) Commercial - State usage # Persons + # Bedrooms Residential - Triplex Residential - Quadplex WASTE TYPES: (Check all applicable) ( ) Commercial or Institutional (X ) Dwelling ( ) Garbage Grinder ( ) Non -domestic wastes ( ) Transient Use Dishwasher ( ) Other (�) Automatic Masher SOURCE AND TYPE OF 14ATER SUPPLY: (X) Well ( ) Spring ( ) Creek or Stream Give depth of all wells within 200 feet of the system: If supplied by community water, give name of supplier: TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: ( Septic Tank ( ) Aeration Plant ( ) Chemical Toilet ( ) Vault Privy ( ) Composting Toilet ( ) Recycling, Potable Use ( ) Pit Privy ( ) Incineration Toilet ( ) Recycling, Other Use ( ) Greywater ( ) Other 'vdILL EFFI DENT BE DISCHARGED DIRECTLY -INTO WATERS OF THE STATE? ( ) Yes (x) No Signature Date INFORMATION BELOW TO BE FILLED OUT BY ENVIRONMENTAL HEALTH OFFICER GROUND CONDITIONS: Percent Ground Slope: Depth to Bedrock (per 8' Profile Hole): Depth to Groundwater Table: SOIL PERCOLATION TEST RESULTS: Minutes per inch in Hole No. 1 Minutes per inch in Hole No. 2 Minutes per inch in Hole No. 3 FINAL q3�POSAL BY: ( ) Absorption Trench, Bed or Pit ( ) Evapotranspiration : 5 r ( ) Above Ground Dispersal ( ) Sand Filter Underground Dispersal ( ) 'Wastewater Pond �' ( ) Other FEE: $SO z APPLICATION No. 859 OWNER: Donald Boyer LEGAL DESCRIPTION: Tract 47 - 0726 Willits Lane RURAL. ADDRESS: TYPE OF DI ELLINQ : Single family dwelling DATE OF TEST: 2 g TEST HOLES PRESOAKED: YES NO 3 # OF BEDROOMS: TYPE OF SOIL: TIME II WATER DEPTH 11 INCHES OF FALL RATE 1 2 3 ! 1 2 3 1 2 3 1 2 3 41; r Z 6 Z �z Zke- POA aI PERCOLATION PATE: ( / ✓Gam. TANK SIZE: � 0 z - SQUARE FOOTAGE PER BEDROOM: LEACH FIELD SIZE: Site has been reviewed and tested For rcolation rate. We recommend: APPROVAL DISAPPROVAL DATE:— �'-^" GJ — EAGLE COUNTY ENVIRONME,\:TAL HEALTH OFFICER •� ROUTE FORM �� -- �":} �/ r1Ai�E �✓� DATE REFERRED APPLICATION NO. LOCATION .'lease review the attached application and return it and this completed form _o:the Environmental Health Office. 'LA_ NUTELCL Complies with: Yes No Reviewed By Subdivision Regulations- Zo inc, Regulations I Recommend Approval ;omments: 3UILDING: L/ Other omments: Set Backs _ �{ Site L Ass Recommend Approval wGTNEER (not aiVWs,-necessary) Roads Grading Drainage Recommend Appy4A4 omments: r L / I m on'Boyer FD Subject: Site Plan Changes, etc. From: File No.: Date: Environmental Health Department April 20, 1981 Enclosed please find your site plan, as per our phone conversation of last Friday, April 17. You wanted to make some changes as to the proposed location of the leaching field. I'm sorry I was unable to get this site plan out to you before today. I was called out of town unexpectedly. Thank you for your patience. Also, in regards to your question of how far away from the leach field must the septic tank be, the answer is a minimum of 10 feet horizontal distance is encouraged. Erik Edeen advised that he would come to your area on Friday, April 24, and perform the percolation tests for you. He will call you and set up the exact times so that you can meet with him, as you requested. It is necessary that you submit the fees of $75 for the permit fee and $50 for the percolation tests, for a total of $125 before your application can be routed for review after the perc tests. Please make your check or money order payable to: ,Eagle County. Thank you. e Nancy C. Morgan, S �etary Enclosure To: Subject: Donald or Roberta Boyer ISDS Permit From: File No.: Date: Environmental Health April 29, 1981 As per my phone conversation with you this afternoon, enclosed is your Individual Sewage Disposal System Permit. As we also discussed, and as is written in the upper right hand side of the permit, "This does not constitute a building or use permit." Also enclosed is the receipt for fees paid. Thank you. Sincerely, Nancy Morgan, Secret 0496(LDU0726) Willits Lane I NAME l � f R6i�CQ C, BOYER vNO ' JOB NO. 1 cos Lnf-ATInnE BILL TO DATE STARTED DATE COMPLETED DATE BILLED LOP SpLf j,/\ems ' T­) QC. C. 65-1; ' � C� ,�F� I►d L ne Aces JOB COST SUMMARY TOTAL SELLING PRICE TOTAL MATERIAL _--- _ - --- TOTAL LABOR PERMIT No. 496 INSURANCE SALES TAX / OWNER: Donald/Roberta Boyer 0726 Willits Lane - Carbondale, CO 81623 LOCATION: 0726 Willits Lane - Carbondale, CO 81623 Tract #47 I Site plan mailed back 4/20/81 for INSTALLER: Ion Boyer SIZE OF TANK: 1,000 gallon - two -compartment langes to the site plan on leach field and any other changes. DWELLING: Single Family - 3 bedrooms x 200 sq.ft. PERC RATE: one inch/10 minutes (600 sq.ft.) 10 from North s tjT 50' from House Finalized: 7/11/83 By: Sid Fox O J08 FOU M v'/ —