Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
4475 Bellyache Ridge Rd - 194135302002
EAGLE (:7JNTY DEPARTMENT OF ENVIRON!V'_�rAL HEALTH ' PERMIT MUST BE POSTED ON PROPERTY BOX 811 6th & Broadway PLEASE CALL FOR FINAL INSPECTION Eagle, Colorado 81631 BEFORE COVERING ANY PART OF SYSTEM Owner PERMIT® 394 (this does not constitute a building or use permit) JAMES F. AND PATRICIA- KEPHART System Location LOT 13 - BELLYACHE RIDGE SUBDIVISION FILING #1 LicensedInstaller: Donald "Scotty" Davis * Conditional Construction approval is hereby granted for a 1,000 gallon xx Septic Tank or Aerated treatment unit. Absorption area (or dispersal area) computed as follows: Perc rate 1 inches in 10 minutes 800 sq. ft. absorption area per bedroom 300 sq. ft. plus extra footage for dishwasher, clothes washer, and garbage grinder. # of bedrooms 2 x 300 sq. ft. minimum requirement May we suggest a 1,000 gallon septic tank with a minimum 800 sq. ft. leach field. Date September 21, 1979 Inspector FINAL APPROVAL OF SYSTEM: Erik W. Edeen No system shall be deemed to be in compliance with the Sewage Disposal Laws until the assembled system is approved prior to covering any part. S tic Tank cleanout to within 12" of final grade or aerated access ports above grade. Proper materials and assembly. �dequate absorption (or dispersal) area. Adequate compliance with permit requirements. Adequate compliance with County and State regulations/requirements. Date �(/ ✓��% Inspector RETAIN WITH RECEIPT RECORDS AT CONSTRUCTION SITE * CONDITIONS: 1. All .installation must comply with all requirements of the County Individual Sewage Disposal Regulations, adopted pursuant to authority granted in 25-10-104, CRS 1973 amended 25-1-614, CRS 1973 2. This permit is valid only for connection to structures which have fully complied with County Zoning and building requirements. Connection to or use with any dwelling or structures not approved by the building and Zoning office shall automatically be a violation of a requirement of the permit and cause for both legal action and revocation of the permit. 3. Section III, 3.24 requires any person who constructs, alters, or installs an individual sewage disposal system in a manner which involves a knowing and material variation from the terms or specifications con- tained in the application of permit commits a Class I, Petty Offense ($500.00 fine - 6 months in jail or 1... Fl. -� ENVIRONMENTAL HEALTH �+ PERCOLATION TEST FEE EAGLE BOX 850DO 81631 PERMIT FEE $50.00 $25.00 APPLICATION FOR INDIVIDUAL SETh1AGE DISPOSAL SYSTEM PERMIT G� � NO. �7 NAME OF OWNER: p rn to F. l��b i `C Jr `011 GI a KeP►�ao:�TE q- `lq-I ADDRESS: Pa a Box 315Va Co I '/ worK W, NAPE OF APPLICANT: dames F. KtjAar� r �4,lrj:otn Vg_p6r{PHONE 3Z5 ADDRESS: P.©, �nX 3-n Fail Co g1CoaI DESIGN ENGR.. FOR SEPTIC (if necessary): ADDRESS: PHONE LICENSED INSTALLER: ai� Sc0+1- n,vt'S PHONE qQ(0 -34Q2 ADDRESS: Box j G WACOhL Lo IS PERMIT FOR: X) New Installation ( ) Alteration ( ) Repair LOCATION OF PROPOSED FACILITY: County Eaq I Lot Size aC res City or Town, if within City or Town Limits LEGAL DESCRIPTION: L4 13 Ftll'aq I pche Ridge 8 bdi'y !>Lnn WASTES TYPE: X) Dwelling ( ) Commercial or Institutional ( ) Non -Domestic Wastes ( ) Transient Use ( ) Other IS SYSTEM DESIGNED FOR 2,000 GALLONS PER. DAY OR. LESS? (>::� yes ( ) no BUILDING OR SERVICE TYPE: �P� �P� � C,; )4&;uiPber of Persons - T Tumber of Bedrooms ( �) Garbage Grinder (X ) Automatic Washer (X) Dishwasher SOURCE AND TYPE OF WATER SUPPLY: ( Well ( ) Spring Give depth of all wells within 180 feet of system: If supplied by community water, give name of supplier: ( )Stream or Creek GROUND CONDITIONS: Percent Ground Slope: 15°7n y Depth to Bedrock: A��y,G `e"pth .to Groundwater Table: t TYPE OF INDIVIDUAL SEWAGE DISPOSAL SYSTEM PROPOSED: ( ) Septic Tank ( ) Aeration Plant ( ).Vault Privy ( ) Composting Toilet (, ) Pit Privy ( ) Incineration Toilet ( ) Greywater ( ) Other Chemical Toilet Recycling, Potable Use Recycling, Other Use SOIL PERCOLATION TEST RESULTS: Minutes per inch in Hole No. 1 Minutes per inch in Hole No. 2 Minutes per inch in Hole No. 3 iC iC iC iC iC �� i� is iC iC iC iC ?C n ,� L G J� J �4 J JC �1 �L iC i� J� iC i� C iC i� iC iC IMPORTANT! t i APPOINTMENT FOR. FINAL INSPECTION 14US 1' BE 114ADE PRIOR TO COVE IINGr BY C^NT^CTIrTC__ THE INSPECTING ENVIRONMENTAL HEALTH OFFICER. REFER.. TO -PERMIT NUMBER.. NO APPROVAL WILL BE GIVEN ON ANY SYSTEM WITHOUT FINAL INSPECTION. TOLL -FREE NUMBERS 328-7311, Ext. 238 (Eagle area) 949-5257, Ext. 238 (Vail area) 927-3823, Ext. 238 (Basalt area) (OVER) Eagle, -Colorado March 24, 1986 Rudolph Kern P.O. Box 1032 Vail, CO 81658 in account with EAGLE COUNTY DEPARTMENT OF COMMUNITY DEVELOMITENT P. 0. Box 179 Eagle, Colorado 81631 Loan Inspection Fee for property located at 25 00 4475 Bellyache Ridge Road - Bellyache Ridge Subdivision, of 13, Filing 1 TOTAL AMOUNT DUE ` I 1 25 100 Please make check payable to: Eagle County Treasurer _ P. O. Box 179 Eagle, Colorado 81631 LOAN INSPECTION FORM L-}-15 LOCATION: REQUESTOR: T COPIES TO: BILL TO: o r-\ ISDS PERMIT # (- INSPECTION INFORMATION: �`�'� �'> Gt4 0 INSPECTION DONE BY:_s:-tiy DATE: EAGLE COUNTY ENVIRONMENTAL HEALTH ROUTE FORM NAME DATE REFERRED APPLICATION NO. LOCATION Please review the attached application and return it and this completed form to the Environmental Health Office. Complies with: Yew No I Reviewed By Subdivision Regulations Zoning Regulations Recommend Approval x Comments:.- AASEN��(/T �V� D,E%� y'p� D,e/�/,cu/�� d/y #D✓MG' ,t 7- GOT _BUILDING• Set Backs Site Access Other Recommend Approval Comments: FN1 -TNEER: (not X*io necessary) Roads Grading Drainage i Recommend Approval f Comments: Environmental Health Sox 850 Basalt area - (303) 927-3823 Eagle area - 803) 03) 328-7311 Vail area - 949-5257 September 5, 1979 James F. and Patricia Kephart P.O. Box 345 Vail, CO 81557 RE: Individual Sewage Disposal System Permi �706 Lot 13 Bellyache Ridge Subdivision #1 Dear Mr. and Mrs. Kephart: The Eagle County Environmental Health Department requires that ail applications for septic permits be routed to the County Planning and Building departments for comment prior to issuance of the septic permit. Your application for the above property was.routed on August 24, 1979. Listed below are the comr�ents and recommendations made by those departments. If you have any questions or wish to obta-in further explanation, please contact the appropriate y department. 1. PLANNING: Disapproved. An easement is needed for the �►" driveway on the adjacent lot. �- Susan aug n, Planner Box 179 Eagle, CO 81531 Phone: 328-7311, ext. 234 BUILDING: Recommend approval. The Environmental Health Department cannot approve a permito c until it has passed all the requirements of the Planning Department. It would be to your advantage if you begin to��` resolve any problems and/or requirements as soon as possible so as not to delay the issuance of your septic permit any longer than necessary. Sincerely, Erik lei. Edeen Environmental EWE/ncm Health Officer cc: Susan Vaughn, Eagle County Planner OWNER: LEGAL DESCRIPTION: 17K,*4 /.5p- RURAL ADDRESS: PERCOLATION TEST FEE: $50 APPLICATION NO. ,6,� � TYPE OF DWELLING: L �liyC &e� # OF BEDROOMS: / / DATE OF TEST: - .. - % TYPE OF SOIL: TEST HOLES PRESOAKED: YES ✓ NO r 05 LG / C TP TIME WATER DEPTH INCHES OF FALL RATE 1 2 3 1 2 3 1 2 3 1 2 3 2-4 I PERCOLATION RATE: TANK SIZE: SQUARE FOOTAGE PER BEDROOM: �j� LEACH FIELD SIZE: Site has been reviewed and tested for percolation rate. We recommend: APPROVAL DISAPPROVAL DATE: c� EAGLE COUNTY ENVIRONMENTAL HEALTH OFFICER EAGLE COUNTY 551 Broadway Eagle, Colorado 81631 (303) 328 7311 March 24, 1986 Rudolph Kern P.O. Box 1032 Vail, CO 81658 RE: Loan Inspection for property located at 4475 Bellyache Ridge Road - Bellyache Ridge Subdivision, Lot 13, Filing 1 Dear Mr. Kern: All water and sewage disposal system loan inspections are done under the authority of the Eagle County Building Regulations, Section 10, Sub -paragraph 3-A, adopted by the Eagle County Commissioners, September 20, 1982. An onsite inspection of the sewage system on March.21, 1986 revealed that the system is functioning properly with no apparent problems. This system was installed and approved under ISDS Permit #394 on December 10, 1979. It is suggested that individual sewage disposal systems be pumped every three to four years. Water is supplied by Bellyache Ridge Community Water Supply. Enclosed is an invoice in the amount of $25.00, the fee for this loan inspection. If you have any questions regarding this loan inspection, please contact our office. Respectfully, Sid Fox Asst. Environmental Health Officer EAGLE COUNTY /gp Enc. Board of County Commissioners Assessor Clerk and Recorder Sheriff Treasurer P.O. Box 850 P.O. Box 449 P.O. Box 537 P.O. Box 359 P.O. Box 479 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 Eagle, Colorado 81631 0394 Lt 13 Filing 1 Bellyache y` Rd Sdv, 4475 Bellyache Rd{ ` g y g r-- JOB NO. .JOB NAME . Rd, ��:�a3�r- � `� � \� ; `, Parrcl -# 1QA11r,InOnn1 JOB LOCATION BILL TO DATE STARTED DATE COMPLETED DATE BILLED JOB COST SUMMARY TOTAL SELLING PRICE TOTAL MATERIAL BOR PERMIT # 394 5�����'11 i alltiet L- VIE) 1 /4Z ONCE TAX OWNER: JV d I3atri-cia Kephart-- )STS LOCATION: Lot 13 - Bellyache Ridge Subdivision - Filing #1 INSTALLER: Donald Davis SIZE OF TANK: 1,000 gallons OTAL JOB COST DWELLING: Residential - 2 bedrooms x 300 sq.ft. PERC RATE: one inch/10 minutes (800 sq.ft.) GROSS PROFIT 300 sq.ft. plus extra footage for dishwasher, clothes -ESS OVERHEAD COSTS washer, garbage grinder °i° of SELLING PRICE NET PROFIT JOB FOLDER product 278 LA"2!/@ NEW ENGLAND B I I IQ I I GCU IC-IU-/y b --. Go "_ By: Erik Edeen Printed in U.S.A.