HomeMy WebLinkAbout841 McLaughlin Ln - 247106306003INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION
P.O. Box 179 - 500 Broadway • Eagle, CO 81631
Telephone: (970) 328-8755
COPY OF PERMIT MUST BE POSTED AT INSTALLATION SITE. PERMIT NO. 1895-99 BP NO.
OWNER: JAMES AND CYNTHIA FORD PHONE: 970-963-1699
MAILING ADDRESS: 0210 SURRY STREET, CARBONDALE, CO 8162.
APPLICANT: PATRICK FITZGERALD, EAGLE EYE ENGINEERING PHONE: 303-755-4374
SYSTEM LOCATION: 0841 McLAUGHLIN LANE, BASALT, CO TAX PARCEL NO. 2471-063-06-003
LICENSED INSTALLER: FORD -WEST GENERAL CONTRACTING, JAMES FORD LICENSE NO. 61-99 PHONE: 970-963-1699
DESIGN ENGINEER: EAGLE EYE ENGINEERING, PATRICK FITZGERALD PHONE NO. 303-755-4374
INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A FOUR BEDROOM RESIDENCE
1250 GALLON SEPTIC TANK 1034 SQUARE FEET OF ABSORPTION AREA VIA 36 INFILTATOR UNITS AS PER ENGINEER'S DESIGN.
SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN REVISIONS DATED 7/14/99, USING SERIAL DISTRIBUTION. ENGINEER IS RESPON-
SIBLE FOR FINAL INSPECTION. DO NOT BACKFILL ANY PORTION OF THE INSTALLATION UNTIL IT HAS BEEN INSPECTED. BUILDING CERTIFICATE
OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS RECEIVED FINAL APPROVAL.
ENVIRONMENTAL HEALTH APPROVAL: DATE: AUGUST 19, 1999
CONDITIONS:
1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS,
ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED.
2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING
REQUIREMENTS, CONNECTION TO OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS
SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT.
3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO
BE LICENSED.
FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR):
NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM
IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM.
INSTALLED ABSORPTION OR DISPERSAL AREA: 1034 SQUAREFEET(VIA 36 INFILTRATOR UNITS AS PER DESIGN
INSTALLED CONCRETE SEPTIC TANK: 1250 GALLONS IS LOCATED DEGREES AND 39 FEET 6 INCHES
FROM THE NORTHWEST CORNER OF THE HOUSE. SEE ENGINEER'S AS —BUILT DRAWING FOR SYSTEM COMPONENT
LOCATIONS.
COMMENTS: RNGINFwR l $ -PTNAL CERTIFICATION RECEIVED SEPTEMBER 16, 1999
ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS
COMPLETED. j
ENVIRONMENTAL HEALTH APPROVAL / d DATE: S FP TFMRFR 21, 1999
Incomplete Applications Will NOT Be Accepted
(Site Plan MUST be attached)
ISDS Permit # `
Building Permit
APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT
ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY
P. O. BOX 179
EAGLE, CO 81631
328-8755/927-3823 (E1 Jebel)
*
PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00
*
*
* MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER"
PROPERTY OWNER:
MAILING ADDRESS:
James and Cynthia Ford
0210 Surrey St., Carbondale, Co. 81623
APPLICANT/CONTACT PERSON: Patrick Fitzgerald., Eagle Eye Eng.
LICENSED SYSTEMS CONTRACTOR: Ford -West General Contr.(B. Ford)
PHONE: 963-1699
PHONE :30 .:!_M
PHONE: 963-1699
COMPANY/DBA: Ford -West Gen. Contr. ADDRESS: 0210 Surrey St., Carbondale 81623
PERMIT APPLICATION IS FOR: (X) NEW INSTALLATION ( ) ALTERATION ( ) REPAIR
LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM:
Legal Description: lot 12, F1, Ruedi Shores
Tax Parcel Number: 2 710 .30 003
Physical Address: 0841 McLaughlin Lane
BUILDING TYPE: (Check applicable category)
(X) Residential/Single Family
( ) Residential/Multi-Family*
( ) Commercial/Industrial*
TYPE OF
(X )
0841 McLaughlin Ln.
Lot Size:
WATER SUPPLY: (Check applicable category)
Well ( ) Spring ( ) Surface
Public Name of Supplier:
Number of
Number of
Type _
.4b ac
Bedrooms four
Bedrooms
*These systems re q ir- design by a Registered Professional Engineer
G��/
SIGNATURE: � � �rC%� � Date
******************************************************** ** ************
AMOUNT PAID: RECEIPT #: 13 9 DATE: /71
CHECK # : /(� rl CASHIER:
Community Development Department
(970) 328-8730
FAX (970) 328-7185
TDD (970) 328-8797
Email: eccmdeva@vail.net
http: //www.eagle-county.com
EAGLE COUNTY. COLORADO
Date: August 19, 1999
TO: Ford -West General Contracting, Inc.
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
FROM: Environmental Health Division
RE: Issuance of Individual Sewage Disposal System Permit No. 1895-99. Tax Parcel
# 2471-063-06-003. Property Location: 0841 McLaughlin Lane, Basalt, CO.,
Ford residence.
Enclosed is your ISDS Permit No. 1895-99. It is valid for 120 days. The enclosed copy of the
permit must be posted at the installation site. Any changes in plans or specifications
invalidates the permit unless otherwise approved.
Systems designed by a Registered Professional Engineer must be certified by the Engineer
indicating that the system was installed as specified. Eagle County does not perform final
inspections on engineer designed systems. Your TCO will not be issued until our office
receives this certification.
Permit specifications are minimum requirements only, and should be brought to the property
owner's attention.
This permit does not indicate conformance with other Eagle County requirements.
If you have any questions, please feel free to contact the Environmental Health Division at 328-
8755.
cc: files
Eagle Eye Engineering, Patrick Fitzgerald
Community Development Department
(970) 328-8730
FAX (970) 328-7185
TDD (970) 328-8797
Email: eccmdeva@vail.net
http: //www.eagle-county.com
September 23, 1999
James and Cynthia Ford
0210 Surry Street
Carbondale, CO 81623
EAGLE COUNTY, COLORADO
Eagle County Building
P.O. Box 179
500 Broadway
Eagle, Colorado 81631-0179
RE: Final of ISDS Permit #1895-99, Tax Parcel #2471-063-06-003. Property location: 0841
McLaughlin Lane, Basalt, CO.
Dear Mr. and Mrs. Ford:
This letter is to inform you that the above referenced ISDS Permit has been inspected and
finalized. Enclosed is a copy to retain for your records. This permit does not indicate
compliance with any other Eagle County requirements. Also enclosed is a brochure regarding
the care of your septic system.
Be aware that later changes to your building may require appropriate alterations of your septic
system.
If you have any questions regarding this permit, please contact the Eagle County Environmental
Health Division at (970) 328-8755.
Sincerely,
Janet Kohl
Environmental Health Department
Eagle County Community Development
ENCL:Informational Brochure
Final ISDS Permit
cc: files
&i9te eye &9i"eeri"9
10144 e ,_.-:1ewell Av., ##2, 0envee, Ca. 80231
303-755-4374 ecigleye@eceotral.com
Ms. Heather Savalox
Eagle County Env. Health
P. O. Box 179
Eagle, Colorado 81631
Ref: ISDS permit # 1895-99
tax parcel 2471-063-06-003
Ford residence
841 McLaughlin Ln.
Basalt, Colorado
Dear Ms. Savalox:
This letter, and the attached drawings will serve as notification that the ISDS at the above
named location has been installed to my satisfaction, in conformance with the approved design,
and in compliance with Eagle County regulations. I inspected the system September 4, 1999.
The absorption area is 558 square feet, consisting of 36 gravel -less infiltrators in four
trenches, arranged such that the two trenches at a higher elevation will become saturated before
substantial amounts of effluent will flow to the lower two trenches. This gives the same effect as
the permitted serial distribution. Trenches, in spite of some variations forced by sub -grade
conditions such as large boulders, were separated by the required 6 feet of undisturbed soil. The
1250 gallon 2-chamber concrete tank is located such that the center of the access cover of the
first chamber is 39.5 feet from the NW corner of the house, and 14.6 feet from the SW corner of
the house. All distances and directions relating house and ISDS may be taken from the attached
scale drawings.
Sincerely,
F. P. Fitzge al
�a
Colorado Registered
Professional Engineer #19656
--V - -- I I Vill %ju I I I U,3 yC14V I 11FONMr-N I ML NtAL I H page b
Received Sep-07-99 03:04pm from CCITT G3 ENVIRONMENTAL HEALTH page 2
From: F. P.Fitzgeraid Eagle Eye Engineering Faxi303-766-4314 Volcc=J66-4374 To: Hesthoftval6x at: Eagle County Health Dept Page 2 of2 Tuesday, September 07, IM 4M:46 PM
The of M,,;s rising ,tripe
is to fy// the /wo upon r rows
4"p'fo-'p .5iig'?IfiCO'-le omov'-)t'- 0/' //ow
go "n10 the t;Vo lokve'- rows
7'1;)-- /Y>e Is 0
Mode cyuritlq
on,,Y will /icv,- ,7,-adv M6, so/rm',
17S 1 /be pel-&?IrYed sel-io1 disil-ib6diO17.
:lames and Cynthia Ford
ISDS Permit #1895-99
Tax #2471-063-06-003
Eagle County, Colo.
Hom'--Ow'-/e'n CS his Own co'91?-octo", to on 04Y
L???d / Should have n9olized that from oe.,!, conversations.
On —Site Sewage
Soil Absorption System
Sys
tem -stQm Design: FPF, p,e,
AS -BUILT;}
Sppt 4 11.99-Q
'v/
Eagle Eye Enpneering
10144E. Jewell A 1,; 02
R,-aver,, Cblorado 80231
,?W-7,5it-4374
Notes:
*All conveyance pipes are installed with
minimum 1/4" drop per foot.
• All components are installed in a manner
which protects from freezing.
• Septic/ Disposal area is use —restricted. Contact
this company or County Health prior to change
of use, or construction activities of any kind.
*Household plumbing fixtures should be
inspected for leaks at least monthly.
e Septic tank should be inspected biennially and
pumped every 4 years, as required by County.
Clean effluent filter at biennial inspection.
*Any use of a garbage grinder MUST be
strictly for incidental amounts from rinsing.
P/1
1250 gal
concrete tank
with effluent
filter \
Water Supply:
Community Supp/y
Perc. Rate:
33 UPI
Design Flow:
900 CPD
Soils:
1 foot topsoil
over silty sand snd gravel
with cobbles and boulders
to depth investigated, 8 ft.
no groundwater
No existing absorption fields within 200 ft
System designed for a four bedroom house
A = Q Vt A = 900 33 = 1034 sq ft
5 5
50% area reduction taken for infiltrators
1034 sq ft x .5 = 517 sq ft
517 sq ft o 15.5 sq ft per infiltrator = 33.3 infiltrators
INSTALLED: 1250 gallon concrete 2—chamber septic took
with cast concrete baffles and a 4" effluent filter
{t
I
/at 12
\ 1.46 acres
scale.-
1 " = 200 ft
'9.5 1( to
tank //d
proposed
house
cleanout
1 7 4. 6 ft to
tank lid
�26' to
h o us_�T�
.36 infiltrators in 4 trenches of 9 units each.
There is a minimum of 6 ft undisturbed earth between trenches.
Trenches are cut with level bottoms,
minimum depth 2.5 ft below local grade (low side of trench)
Trench bottoms and lower back fill are of finer native material.
Flow is distributed to the full length of each trench by a solid 3"
pipe at the crown of the infiltrators, drilled with two 112" holes
at "4 and 8 o'clock", near the middle of each infiltrator.
James and Cynthia
Lot 12, Filing 1
Ruedi Shores
Eagle County, Colo.
Ford On —Site Sewage
Soil Absorption System
System Design: FPF, p.e.
-o
geo
N N
S e
drive�yaJ'
drkir9
P /
7.5 ft qap between
infiltrator end plates
Zo get past boulder
four trenches with
9 infiltrators each
Zt see next drawing for
details
observation
ports
SCALE- I" = 50 FT
CAT-UILT-B
Sept 13, 1999
Denver, SJ
0 i4
James and Cynthia Ford
IISDS Permit #1895-99
Tax #2471-063-06-003
Eagle County, Colo.
On —Site Sewage
Soil Absorption System
System Design: FPF, p.e.
10 144 E. Je
Denver, Colorado 80231
303-755-4374
,Eagle Eye &9i"eeein9
10144 & ,,7ewell c4v., #2, De"vev, Coto. 80231
INDIVIDUAL SEWAGE SOIL ABSORPTION SYSTEM
SITE DESIGN SUMMARY
July 14, 1999
PROPERTY OWNER: James and Cynthia Ford
0210 Surrey St., Carbondale, Colo. 81623
PROPOSED APPLICATION: Four bedroom residence.
LOCATION: Lot 12, filing 1, 0841 McLaughlin Ln., Ruedi Shores, Eagle County, Colorado
tax Parcel ID #247106306003
SOILS: One foot topsoil, then silty sand and gravel with cobbles and boulders to depth investigated, 8 ft.
GROUNDWATER: No evidence of groundwater to maximum depth.
SEPTIC TANK:
Flow: (4 bdrm)x(2 per)x(75 gpd)x(1.5) = 900 GPD
Tank Size: Per section 4.07.01, table 4, use 1250 gallon
PERCOLATION TEST: conducted May 24, 1999, by HP-Geotech
test hole #1: stable absorption rate for 45 minutes. Rate 30 MPI
test hole #2: stable absorption rate for 45 minutes. Rate 30 MPI
test hole 43: stable absorption rate for 60 minutes. Rate 40 MPI
Average rate 33 MPI
ABSORPTION AREA: Area slope is a uniform 14% to the SSW
A= (Q * t5)/5 = (900 * 33 5)/5 = 1034 sq ft
Request 50% area reduction for the use of infiltrators:
Area =1034*.5=517sgft
At 15.5 ft' per unit: 517 / 15.5 = 33.3 infiltrators
Install: 1250 gallon concrete 2-chamber septic tank with cast concrete baffles and a 4" Orenco effluent filter.
Order the tank to be cast without its effluent baffle, to avoid the necessity of removing it in the nerd.
36 infiltrators in 4 trenches of 9 units each. Units are 3 ft by 6 ft. Trenches must be dug parallel to the contours of
the slope. There must be a minimum of 6 ft of undisturbed earth between trenches. Trenches must be cut with a
level bottom, minimum 2.5 ft below local grade (low side of trench). Remove cobbles and boulders from the
bottoms: moderately compact and re -level the trench bottoms. Trenches will be connected in series. Infiltrator
units must be firmly bedded in fine native soil, strictly per the manufacturer's requirements, prior to machine
placement of the backffll.
Distribute flow to the full length of each trench by hanging a SOLID 3" SDR-35 pipe at the crown of the
infiltrators. Prior to installation, drill this pipe with ONE PAIR of/z" holes at the "4 and 8 o'clock" positions,
near the middle of each infiltrator unit. Connect these pipes in series, as shown in the drawing. Place inspection
ports in each row, as shown in the drawing.
All piping MUST be firmly bedded in fine native soil before backfilling.
Notes:
surface grade
e All conveyance pipes to be installed with
minimum 1/4" drop per foot.
for connector
*All components to be installed in a manner
-__-
which protects from freezing.
Extend septic tank risers to for
ft
end view w o
• grade or mark
of infiltrators 1
winter -time access; triangulate on as -built.
29 W
• Schedule 40 installed between any system
serial connection
components subject to vehicle activity.
• Septic/ Disposal area is use -restricted. Contact °tpe
this company or County Health prior to change
lot 12
of use, or construction activities of any kind.
w geo
1.46 acres
• Household plumbing fixtures should be
inspected for leaks at least monthly.
e Septic tank should be inspected yearly and
��JE
pumped every 2 years, as required by County.
S
Clean effluent filter at annual inspection.
P�
*Any use of a garbage grinder MUST be
strictly for incidental amounts from rinsing.
?°
PROPOSED HOUSE
drivecv y�
1250 gal
o
concrete tcnk
with effluent
dfkin9
filter
P
Water Supply: Community Supply
Perc. Rate: JJ UP/
Design Flow: 900 OPD
soils: 1 foot topsoil
ET
over silty sand snd gravel
�� ��5
With cobbles and boulders
0 E be
200U5 Infiltrators
to depth investigated, 8 ft.
C/O
must
no groundwater
bedded with fine
native soi/,
'--" strictly per mfg's
No existing absorption fields within 200 8
�0� �� requirements.
36 infiltrators
connector
4 trenches of JZ
9 units each \
System designed for a four bedroom house
ports °
connector r\�
ports pJA
A = Q V—t A = 900 33 = 1034 sq ft
5 5
50% area reduction requested for infiltrators
1034 sq ft x .5 = 517 sq ft
517 sq ft a 15.5 sq ft per infiltrator = 33.3 infiltrators
INSTALL: 1250 gallon concrete 2-chamber septic tank
with cast concrete baffles and a 4" Orenco effluent fi/ter
Order the tank to be cast without its effluent baffle.
_connector �G
�- p/f
� offsets tr
10 ft
SCALE- I" = 50 FT
56 infiltrators in 4 trenches of 9 units each.
Trenches must be dug paral/el to the contours of the slope.
There must be a minimum of 6 ft undisturbed earth between trenches.
Trenches must be cut with a level bottom,
minimum depth 2.5 ft below local grade (low side of trench
Remove cobbles and boulders from the bottom, re -tamp bottom level.
Trench rows w111 be connected in series, with ports, as shown.
TR�
July 14, 1999
supersedes 7/8%99
de
Distribute flow to the full length of each trench by hanging a
SOLID 3" SDR35 at the crown of the infiltrators, to about J' from raw's end.
Drill this pipe with ONE PAIR of 112" holes at "4 and 8 o'clock';
near the middle of EACH INFILTRATOR UNIT. No cop on pipe.
James and Cynthia Ford On —Site Sewage Eagle Eye Engineering
Lot 12, Filing 1 Soil Absorption System 10144E Jewell Av, *2
R u e d i Shores Denver, Colorado 80231
Eagle County, Colo. 303-7554374
System Design: FPF, p.e.
flepworthPawlak Geotech TEL:970-945-8454
Jul 07 99 8:04 No.006 P.01
June 17, 1999
James Brandon Ford
Givechnival, Dian.
5020 Counly Road 1.54
GMaVAYAW (yiNnLg, i.Morado 816A)l
Mane, 970-969-79HR
Uet= 970-54S-3454
10 Surrey Street
Carbondaie, Colorado 81623 Job No, 199 401
Subject: Percolation Test Results, Proposed Residence, Lot 12, Filing 1, Ruedi
Shores, McLaughlin, Eagle County, Colorado
Dew- Mr. Ford:
As requested, we have conducted percolation testing kit the subJect site to evaluate the
fbasibility of an 'Infiltration septic disposal system at the she. The results of ouF work
ark Paeseng�oW in d4i6- se C rt. `ale wok Was done in accordance With oug. agreenlant for
pFof° ssional services to ycyd dated May 17, 1999.
A profile pit and three shallow backhae pits were excavated at the locations. shown on
Fig. I by others prior to our testing, We understand that the peFcalation test, holes were
hand dug at the bottom of the shallow backhoe pits and soakod oml day prior to mir
testing. The soils exposed in the percolation holes and profile pit consist of about I foot
of top. ofl overlying silty sand and gravel with cobble,,; and hcnzld�rs to the proffle pit
depth of 8 feet, No free water was encountered in the nits and the subsoils were
slightly moist to nioi.q.
Percolation tests were perfonned on May 24, 1999 by a representative. of Hepworth -
Pawlak Geotechnical, Rne. The percolation test results are, shown on Table I. The
percolation test results indicate and infiltration rate bemeen 30 and 40 gninums per inch
with an average of 33 Yninutes per inch. Based an the subsurface conditions
encountered and percolation test results, the tested area should be suitable for a
Conventional infiltration septic: disposal system,
If you have arty questions or if we, can of further assislauce, please cell our officc
HE'PWORT27I - PAWLAK GEOTECHNRCAL, INC.
Jordy Z. Adamson, Jr, P.E.
JZA/ksyn
HepmorthPamlak 5eotach TEL:970-945-8454 Jul 07 99 8:05 No.006 P.02
HepworthPawlak Geotech TEL:970-945-8454 Jul 07 99 8:05 No.006 P.03
HEPWORTH-PAWLAK GEOTECHMCAL, WC.
mmm"I
NOTE-1 POrc0laflon 1621 hoea wam hand dug In IhG F,-?�Ogjj of r7acki-,op plia and Soakad by 01hem. POKOWRIJOID jeatz Wava
conduuted on May 24, 199-9, 7ho avezage, pcFGQ1fijjQUu rate wa's haso(I On the Past IWO redztfinga of cacti iw,