Loading...
HomeMy WebLinkAbout326 Strohm Cr - 211106407002INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT EAGLE COUNTY ENVIRONMENTAL HEALTH DIVISION P.O. Box 179 - 500 Broadway • Eagle, CO 81631 Telephone: (970) 328-8755 COPY OF PERMIT MUST BE POSTED AT INSTALLA TION SITE. PERMIT NO. 2063-01 BP NO. TOWN OF GYPSUM OWNER: IVAN ELLIOTT PHONE: 970-524-9493 MAILING ADDRESS: P.O. BOX 650, GYPSUM, CO 81637 APPLICANT: SAME PHONE: SYSTEM LOCATION: 216 STROHM CIRCLE, GYPSUM CO TAX PARCEL NO. 2111-067-07-002 LICENSED INSTALLER: BOOK AND SONS EXCAVATING. RON BOOK LICENSE NO. PHONE: 970-390-2561 DESIGN ENGINEER: LKP ENGINEERING LUIZA PETROVSKA PHONE NO. 970-926-9088 INSTALLATION HEREBY GRANTED FOR THE FOLLOWING: MINIMUM REQUIREMENTS FOR A 4 BEDROOM RESIDENCE 1500 GALLON CONCRETE SEPTIC TANK, 1488 SQUARE FEET OF ABSORPTION AREA CREDIT, VIA 48 INFILTRATOR UNITS AS PER ENGINEER'S DESIGN SPECIAL REQUIREMENTS: INSTALL AS PER ENGINEER'S DESIGN DATED 01/10/01. INSTALL INFILTRATOR CHAMBERS OVER A MINIMUM OF TWO FEET OF CLEAN SAND IN THE TRENCHES AND INSPECTION PORTALS IN EACH TRENCH. BE SURE TO MAINTAIN ALL SETBACK REQUIREMENTS AND DO NOT INSTALL IN WET WEATHER. THE LEACH FIELD MUST BE FENCED OFF AS PER THE ENGINEER'S RECOMMENDATION AS STATED IN THE REVISION LETTER DATED 1/24/01, A COPY OF WHICH IS INCLUDED WITH THE PERMIT. THE ENGINEER IS RESPONSIBLE FOR THE FINAL INSPEC- TION. DO NOT BACK FILL ANY PART OF THE INSTALLATION UNTIL THE ENGINEER HAS INSPECTED AND APPROVED IT. THE BUILDING CER- TIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THE SEPTIC SYSTEM HAS BEEN INSPECTED AND APPROVED. /i ENVIRONMENTAL HEALTH APPROVAL: �f "I 4t l DATE: JANUARY 26.2001 CONDITIONS: 1. ALL INSTALLATIONS MUST COMPLY WITH ALL REQUIREMENTS OF THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS, ADOPTED PURSUANT TO AUTHORITY GRANTED IN 25-10-104, 1973, AS AMENDED. 2. THIS PERMIT IS VALID ONLY FOR CONNECTION TO STRUCTURES WHICH HAVE FULLY COMPLIED WITH COUNTY ZONING AND BUILDING REQUIREMENTS. CONNECTION TO, OR USE WITH ANY DWELLING OR STRUCTURE NOT APPROVED BY THE ZONING AND BUILDING DEPARTMENTS SHALL AUTOMATICALLY BE A VIOLATION OF A REQUIREMENT OF THE PERMIT, AND WILL RESULT IN BOTH LEGAL ACTION AND REVOCATION OF THE PERMIT. 3. CHAPTER IV, SECTION 4.03.29 REQUIRES ANY PERSON WHO CONSTRUCTS, ALTERS OR INSTALLS AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM TO BE LICENSED. FINAL APPROVAL OF SYSTEM (TO BE COMPLETED BY INSPECTOR): NO SYSTEM SHALL BE DEEMED TO BE IN COMPLIANCE WITH THE EAGLE COUNTY INDIVIDUAL SEWAGE DISPOSAL SYSTEM REGULATIONS UNTIL THE SYSTEM IS APPROVED PRIOR TO COVERING ANY PORTION OF THE SYSTEM. INSTALLED ABSORPTION OR DISPERSAL AREA: 1488 SQUARE FEET (VIA 48 INFILTRATOR UNITS ) INSTALLED CONCRETE SEPTIC TANK: 15 0 0 GALLONS IS LOCATED 9 0 DEGREES AND 38 FEET INCHES FROM "THE EASTERN CORNER OF THE HOUSE FOUNDATION. COMMENTS: THE FINAL INSEPCTION WAS DONE BY WILLIAM CARLSON OF EAGLE COUNTY ENV - HEALTH ON 9-11-01. THE DESIGN ENGINEER INSPECTED THE SYSTEM ON 9-11-01, THE ENGINEER'S FINAL CERTIFICATION WAS RECEIVED ON 10-4-01. THIS SYSTEM IS LARGE ENOUGH FOR A 4 BEDROOM RESIDENCE. ANY ITEM NOT MEETING REQUIREMENTS WILL BE CORRECTED BEFORE FINAL APPROVAL OF SYSTEM IS MADE. ARRANGE A RE -INSPECTION WHEN WORK IS COMPLETED. ENVIRONMENTAL HEALTH APPROVAI&JI/I % 7 ( l I✓t�ij DATE: CC`I OBER 11 , 2 0 01 Incomplete Applications Will NOT Be Accepted _(Site Plan MUST be attached) ISDS Permit ##.:. 1-6 Building Permit # APPLICATION FOR INDIVIDUAL SEWAGE DISPOSAL SYSTEM PERMIT ENVIRONMENTAL HEALTH OFFICE - EAGLE COUNTY P. O. BOX 179 EAGLE, CO 81631 328-8755/927-3823-(El Jebel) * FEE SCHEDULE * PERMIT APPLICATION FEE $150.00 PERCOLATION TEST FEE $200.00 * SIZING AND SITE VISIT FEE $85.00 (WHEN ENVIRONMENTAL HEALTH SIZES THE * SYSTEM USING YOUR SOILS REPORT) * MAKE ALL REMITTANCE PAYABLE TO: "EAGLE COUNTY TREASURER" ************************************************************************** PROPERTY OWNER: !/� �y 47 MAILING ADDRESS: ��% �`� / ` J -?7 PHONE:15 APPLICANT/CONTACT PERSON: �-UOt� �I 1 t o` PHONE: 7- 91 LICENSED SYSTEMS CONTRACTOR: : r� LsQi),s, PHONE: liO^ ZSW COMPANY/DBA: '�tSr S Gxca,kl�DDRESS : *************************************************************************** PERMIT APPLICATION IS FOR: ( NEW INSTALLATION ( ) ALTERATION ( ) REPAIR LOCATION OF PROPOSED INDIVIDUAL SEWAGE DISPOSAL SYSTEM: Legal Description: Tax Parcel Number: 02 i/ I - D�0 `� �� Lot Size: Physical Address: BUILDING TYPE: (Check applicable category) (' Residential/Single Family Number of Bedrooms ( ) Residential/Multi-Family* Number of Bedrooms ( ) Commercial/Industrial* Type *These systems require design by a Registered Professional Engineer TYPE OF WATER SUPPLY: (Check applicable category) ( ) Well ( ) Spring ( ) Surface t� K) Public Name of Sup Z�,r I SLAM-' APPLICANT SIGNATUR Date: AMOUNT PAID: L RECEIPT # : o I U DATE: CHECK #: CASHIER: Community Development Department (970)328-8730 FAX (970) 328-7185 TDD (970) 328-8797 Email: eccmdeva@vail.net http: //www.eagle-county.com EAGLE COUNTY, COLORADO Date: January 26, 2001 TO: Book & Sons Excavating FROM: Environmental Health Division Eagle County Building P.O. Box 179 500 Broadway Eagle, Colorado 81631-0179 RE: Issuance of Individual Sewage Disposal System Permit No.2063-00. Property Location: 216 Strohm Circle, Gypsum, CO., Elliott residence. Enclosed is your ISDS Permit No. 2063-00. It is valid for 120 days. The enclosed copy of the permit must be posted at the installation site. Any changes in plans or specifications invalidates the permit unless otherwise approved. Please note any special requirements that may have been added to the design by this department. Systems designed by a Registered Professional Engineer must be certified by the Engineer indicating that the system was installed as specified. Eagle County does not perform final inspections on engineer designed systems. Your TCO will not be issued until our office receives this certification. Permit specifications are minimum requirements only, and should be brought to the property owner's attention. This permit does not indicate conformance with other Eagle County requirements. Please notify this office if you have not been contracted to perform this installation. If you have any questions, please feel free to contact the Environmental Health Division at 328- 8755. cc: files LKP Engineering, Luiza Petrovska DEPARTMENT OF ENVIRONMENTAL HEALTH (970)328-8755 FAX (970) 328-8788 TDD: (970) 328-8797 TOLL FREE: 800-225-8136 www.eagle-county.com EAGLE COUNTY. COLORADO October 11, 2001 Ivan Elliott P.O. Box 650 Gypsum, CO 81637 Raymond P. Merry, REHS Director RE: Final of ISDS Permit #2063-01, Tax Parcel #2111-067-07-002. Property location: 216 Strohm Circle, Gypsum, CO. Dear Mr. Elliott: This letter is to inform you that the above referenced ISDS Permit has been inspected and finalized. Enclosed is a copy to retain for your records. This permit does not indicate compliance with any other Eagle County requirements. Also enclosed is a brochure regarding the care of your septic system. Be aware that later changes to your building may require appropriate alterations of your septic system. If you have any questions regarding this permit, please contact the Eagle County Environmental Health Division at (970) 328-8755. Sincerely, Janet Kohl Eagle County Environmental Health Department ENCL: Informational Brochure Final ISDS Permit cc: files OLD COURTHOUSE BUILDING, 551 Broadway, P.O. Box 179, Eagle, Colorado 81631-0179 Date 177 II7-1Z:Y JSDS Permit iS Final Inspection --- Comleteness-Form Tank is gal. Tank Material Tank. is located ft. anddegrees from (permanent landmark) Tank is located ft. and _degrees from (permanent landmark) /�3 Tank set level. Tank lids within 8" of finished grade. size of field is lineal ft. Technology. Cleanout is installed in between tank and house(+ 1/100f t) There is a "Tn that goes down 14 inches in the inlet and outlet of the tank; Inlet and outlet is sealed with tar-,tapej- 1Y e�rga�-s��etc Tank. -has two .:compartments with the,,flla.r.r-.•.com -p artment closest to house. -.,Maabure: distance and relative direp-tioA.-to:,,,f.1e.1.1 Depth of field. ft. Soil interface raked. Inspection portals at the.end of each trench.. Proper distance to setbacks. ---�Chambers properly installed as per manufacturers specifications. (chambers latched, end plates properly installed, rocks 'removed from trenches, etc.) Type of pipe used for building sewer line _ , leach field Other Inspection meets requirements. Copy form to installer's file if recorimendations for improvement. were suggested. f-,n! ACTION TAKEN: V- JJ, � —, r) Sit J, 7� Setbacks )� X Ai Well 'Potable House Property Lake Dry Tank Drain Water Lines line Stream Gulch Field 100 25 20 10 so 25 10 10 Tank so 10 5 10 50 10 10 (7 J" Vj A, I I 11 KP �- N, N�- {- W I NI-1 . - - ------ ....... INU FAUL Ui rl Fngm*ee Ougg Inc. ri aVUiUEOTECJUq1CAL Aviq)) XC: Jnspection of Septic System Installation P.O. Box 650 Lot 15, Bertroch Subdivision Filing No. 6 Gypsum, CO 81637 216 Strohm Circle., Gypsum,. Eagle County, Colorado Project No. 0101 - ISDS Permit No. 2063-00 Dear Ivan: At the request, of Ron Book on September 12, 2001, we visited f1je construction site on Lot 15, Bertrocb Subdivision Filing No. 6, 216 Strohm Circle, Gypsum, Eagle County, Colorado. The Purpose of our site visits was to inspect the installation of the septic system. They installed the system. Iri overall cornpliance with the septic system desigil., Drawing No, OIOISD.DWG, dated Januaty 10, 2001. The system was installed as shown. on the attached, as -built sketch. Thev installed a 150Q-gallon, two compartments, a precast, concrete septic tank. A cleanoutA),as installed between the house and the septic tank. Forty-eight Standard Infiltrator Chambers were installed in four. trenches. The first trench contained 13 infiltrators, the sc,=nd and third trenches each had 12, and the fourth had 11. The infiltrators were conriected with serial distribution. In the first and last infiltrator of each trench, inspection ports were installed. If you have any questions, please do not hesitate to call. sincerely, LKP En'gineerb Petrovska, President Enclosure cc: Mrs. Laura Fawcett, Eagle County Building Department, fax., 328-0349 CAMYFi1cs\coreJdOc\WPDOCS\O 10 1 OSI,doc 1, P.O. Box 2837, Edwards, CO 91632, (970) 926-9088'tol, (970) 926-9089 Fax nnnr-. 4 10/04/2001 12:4b 9 /092b9089 LISP 1--N6lNEEKllNG INU HA(-iE U2 rLKp) Engmleermig, Inc. (-�SD�.S PRO✓CCT oESC&PAU.- tfi ZIG FRC) Hh efg PAuipor No.: DATE. II LL 1 1 RO. Box 2837, Edwards, CO 81632, (970) 926-9088 TO, (970) 926-9089 Fax, January 24, 2001 Ms. Laura Fawcett Eagle County Environmental Health Department Via Fax: 328-0349 Dear Laura: WE,: Revisions to the Septic System Design Lot .4.5, Bertrocli Subdivision, Filing No, 6 Eagle County, Colorado Project No. 0101 This letter is a su septic system design we prepared for Mr. Ivan T-,lliott f pplement to the . s p or his proposed residence on Lot IS, Bertrooli Subdivision Filing No, 6, Eagle County Colorado. The Proposed leachfield for the septic system is located in the easement of Holy Cross Energy, and it is under the existing power lines. Also, thank you for the copy of the letter from Holy Cross Energy, which allows the installation of the leachfield within their easemeiit. As stated in the design dxawing, dated January 10, 2001, Item 8 from the notes, Traffic over the system should be avoided. In. order to protect the leachfield from traffic of mainteilailce, vehicles, we recommend that a fence be installed at its perimeter. If you have any questions, please do not hesitate to call. us. § LKP Engineerinff P,F: 26 Luiza Petro vska,'J.? President Origin -al mailed to Mr. Ivan Elliott. C!\Ni,(ypilesl,coreldooilTDC�_1310 I() tyr_E�r.V,1pD F.O. Box, 2837, Edwards, Colorado 81632 * (970) 926-9088 Tel b (970) 5)2&9089 Fax JAN-24-2001 WED 10:42RM ID:ERGLE COUNTY ENV HEALTH PAGE:1 01/18/2001 12:36 9709269089 LKP ENGINEERING INC PAGE 02 Hepworni-PawlaR GeDteCh11kft1i 1"C- 5020 cou" Road 154 G1eRWqqd ZpriiAgF7 Colorado 81601 pbooe.- rO-945-79$8 Fax: 970-945-84-54 hpgeoOhpgeotecfk,com December 14, 2000 Bedrock construction Attn: Wayne Conrad P,o. Box 425, Job No. 100 814 Eagle,, Colorado 81631 Subject: Percolation Testing, Proposed Septic Disposal System, Lot 15,.Filing 6, Bertroch Subdivision, 216 Strohm Circle, GYPSUM, Colorado, Dear Mr. Comad: As requested by Pon Book with Book Construction, a representative of Hepworth- pawlak Geote&aical, Inc. conducted percolation testing at the subject site to evaluate the feasibility of an infiltration septic disposal system. The results of our work are presented in this report. we previously conducted a subsoil study at the site and presented our findings in a report dated October 17, 20M, Job No. 100 814. A profile pit and three shallow backhoe pits were excavated at the locations shown on Fig. 1. Percolation test holes were hand dug in the bottom of the backhoe pits. The test holes were soaked, one day prior to testing. The holes were covered with rigid foam insulation to protect against freezing overnight. The soils exposed in the percolation holes are similar to those exposed in the profile pit and consist of about 1/2 foot of topsoil and 4 feet of clayey sand and gravel with rock fragments up to boulder size overlying weathered siltstone/claystane bedrock to the profile pit depth of 81/2 feet. Groundwater was not observed is the profile pit and the soils were slightly moist to moist. Percolation. tests were performed, on December 13, 2000 by a represeatative of Hepworth-Pawlak Geott--chuical, Inc. The percolation test results are presented on Table 1. The ground temperature was about 34- at the time of testing. The percolation test results indicate an infiltration rate bet-,,veen about 5 and 40 minutes per inch. Based 01/18/2001 12:36 9709269089 LKP ENGINEERING INC PAGE 03 Bedrock Construction December 14, 20M Page 2 on the shallow bedrock encountered in the profile pit, the town may require that a civil enineer design the septic disposal system, If here are any questions or if we may be of further assistance, please let us know. Sincerely, HEPWORTH - PAWLAK GE IN F REG AbA attaclunents H-P GMTECH 01/18/2001 12: 36 9709269089 LKP ENGINEERING INC PAGE 04 M PERCOLATION TEST RESULTS JOBNO. 100 814 HOLE NO. HOLE E LENGTH WA I TER DEPTH ATER DEPTH SAT END OF DROP IN WATER AVERAGE P RCOLAT ON (INCHES) INTERVAL T START OF INTERVAL INTERVAL LEVEL' RATE (MIN) (INCHES) 32 { 7 -% ' grater added water added '%y 'la S 2 1/2 G water added 7/2 3 i2 r.qgi/2 py ey 36 16 $ 5� /2 8 T /2 7 y/2 7 'la 14 !� 4 2f4 � 440 P-3 47 is 7fx � $ '/2 6 4 3 water added � 4 f2 4 1A � , f� � 20 Note., Percolation test holes were hand dug in the bottom of backhas pits and soaked on December 12,2000.- The holes were covered with rigid foam insulation to protect against freezing overnight, Percolation ..... s were December '0 0. The average percolation rates werebasedon the last two readingsf each test. TC)F,I- 1 0.-aWA-1 TWI I I 'D - 77Dhl Tri - Dnr-1 C rr-11 JKITV I=Kll I Ul=nl TU DOf--C* - CZ GROSS F O GN 1 r O dd 1- �� SSO'O January 15, 2001 Ms. Janet Kohl Eagle County Environmental Health P.O. Box 179 Eagle, CO 81631 3799 HIGHWAY 82 • P.O. DRAWER 2150 GLENWOOD SPRINGS, COLORADO 81602 (970) 945-5491 • FAX (970) 945-4081 RE: Holy Cross Energy Easement — Lot 15, Filing 6, Bertroch Subdivision Dear Ms. Kohl: Holy Cross Energy will allow the installation of a sewer septic system leach field within the above mentioned easement under the following conditions: A. The proposed system neither disturbs existing poles nor reduces clearances to the overhead primary electric line. B. All personnel and equipment used during the initial installation, as well as any future maintenance of said system, will maintain safe clearances in accordance with all applicable rules and regulation. Should you have any questions, please contact me at 748-4306. Sincerely, Holy Cross Energy 5,:,- ��/ 5?Z4 Ted Huskey Engineering Services Supervisor TH:eah cc: Holy Cross Energy Vail Office 7671 Date 127- pages Post -it" Fax Note To �1,11From 'ZGt t ekFbVSi.� -- Co. Q , Co./Dept. K >+% Phone # Phone # �+ Fax # Fax# 0-i 1 -_!.j (') \ i PERMISSION HAS BEEN OBTAINED V BY THE CLIENT FROM HOLY CRESS ENERGY TO CONSTRUCT THE LEACHFIELO INTO THE EASEMENT A 32°10'47 S 28*50'10" E 305.48' = " R = 145.00' 1500 GAL TWO COMP. 4" DIAM. SOR.35 11 T = 41.83' CONC. SEPTIC TANK 1 11 ' (Jp 1. 5' LC= N 83°32'48" E p -420'80.37' 4" DIAM BLDG SEWER / CLEANOUT STANDARD INFILTRATOR TYPICAL PROPOSED 2 I o o INSPECTION PORT J \ ° SERIALDISTRIBUTION (V(2 \ 5.0' Jj/ .J = 10'07'41 " R = 280.19 / T 24.83, \ / L = 49.53' LC= N 26°2445" E 00 J 49.46' >>a v` 301.34' �O N 31 °42' 28 W 18" MAXIMUM SERIAL DISTRIBUTION WITH A SAND FILTER �-- 90° ELBOW , GROUND SURFACE DETAIL A - A 90' ELBOW SAND FIL TER 20 STANDARD INFIL TRA TOR GRAPHIC SCALE 0 10 20 40 ( IN FEET ) 1 inch = 20 ft. r F`` a PERCOLATION TEST RESULTS \ Pgrrc No, 1 Perc No. 2 Perc No. 3 ! 5 minutes per inch 40 minutes per inch 20 minutes per inch i Average percolation rate recommended for design T = 22 minutes per inch. Perc test and soil profile by HP Geotech. t SOIL PROFILE 1 UPROFILE HOLE VIV 0 to 0.5 feet Topsoil 0.5 to 4.5 feet clayey sand and gravel with rock fragments up to boulder size 4.5 to 8.5 feet Weathered Silts ton%laystone bedrock. ,DESIGN CAL CULA BONS Design percolation rate T = 22 minutes per inch Number of bedrooms = 4 Maximum daily Flow = Omax 0max = 4 bdrms x 2 persons/bdrm x 75 ga/lons/persony'day x 1509 Om ax = 900 gp d N SEPTIC TANK V = 0rnax/24hrs x 30 hrs V = 7125 gallons Use 1500 gallon, two compartment preccst concrete tank by Copland Concrete or equivalent ABSORPTION AREA A = Omax/5 x VT A = 90015 x V22 = 344 s. f Based on Applicatio Rate: A = 900go d10. 6 go d1s. f. 80 A = 1500 s. f Standard Infiltrator Chamber System in a trench configuration with an allowed 50 p ercen t reduction in the absorption area is recommended. Acorrected = 750 s. f. N Surface area of one Infiltrator Chamber = 15.5 s. f. Use 48 Infiltrator Chambers in trenches, as shown on the plan. N\' Due to the closeness of the weathorred bedrock, each trench will be overexcavated a minimum of two feet. 1 "r The trenches will be filled with a rrfiinimurn of 2 feet of medium sand filter. NOTES: 1. Bends in the building sewer shall be limited to 45 degrees. 2. The septic tank sholl'be installed level. The tank shall have removable covers or manholes to within 8 inches of the finished -grade, for inspection and cleaning. 3. Excavato,-Puree (3) feet wide trenches. The horizontal distance from sidewall to sidewall between the ttrerchshcll be a minimum of six (6) feet. 4. Place and compact, by wetting, two feet or' sand filter at the bottom of the trenches. The sand filter 'sftll be clean sand, consisting of 88 to 937 sand and 7 to 12% finer grained material with a design infiltration rate of 1.2 gpd/sq. ft. 5. Assemble and install the Infiltrator Chambers in the trenches according to the manufacturers recommendations. 6. Backfill the sidewall area with native on —site soil for proper support. 7. Backfill the trenches with a minimum of 12 inches of tamped soil cover. 8. Avoid vehicle traffic over the system. 9. All installations shall meet the rules and regulations of the Eagle County Environmental Health Division, Chapter 4, Individual Sewage Disposal Systems. 10. The Septic System Installation shall be inspected by the Design Engineer prior to bockfilling. 1500 GALLON TWO COMPARTMENT CONCRETE SEPTIC TANK 4'- 5'-8" N PLAN VIEW SIDE VIEW NOTE: TOPOGRAPHICAL MAP BY WHITE SURVEYING, DATED MARCH 3, 1995, BUILDING FOOTPRINT DIGITIZED FROM PLAN BY CLIENT. al 9 Q Q, Z • G00 O N 0) � I cD �p N 01-1 M i\ U `- � x O L.Li v 00 00 \ rj 0 00 CN U N m rn o O� CL DRA WN B Y.• L. P. CHECKED BY.. L. P. PRO✓EC T NO.: 0101 DA TE: 01-10-2007 DRA WING NO.: 0101 SD. D WG N. T. S. BY COPLAND CONCRETE OR EQUIVALENT SHEET 1 OF 1 46' 4y JAN 7-4 Sow